Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KINFR_627456_1Bid Award Id
ViewTender No
KINFRA/MFP/26/2023-24Tender Authority
Kerala Industrial Infrastructure Development Corporation ViewPurchaser Address
-Website
http://http://kinfra.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
22 KV DP STRUCTURESupply, fabrication, erection, testing & commissioning of 12 mtr ,22 KV DP structure using 100X200 mm ISMB and cross channel of ISMC 50X100mm and supporting structure for 22kV components 22 KV pin, disc and stay insulators, supports, jumpering /interconnecting conductors with '0'SWG Cu, 25x3mm braided copper earthing for non-conductor moving part like handle of AB switch, earthing etc.on suitable concrete foundation etc complete .( Note:All the MS items shall be hot dip galvanised)22 KV, gang operated AB switch with operating handle & locking mechanisThe structures shall be braced with ISMC 50X100mm.Interconnection shall be done with 0 SWG Cu wire.m -1 set22 KV Lighting Arrestors -1 set 22 KV D.out fuses -1 set The DP structure shall be with all necessary accessories like nut,bolt,washer,supports etc for connecting 22kV cable as per particular specification. Civil Foundations are considered seperately
1
-
-
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3
coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including
excavation and refilling etc. as required. Above 11.00 metre and upto 13.00 metre
2
-
-
Supplying of 22 kV, XLPE insulated, heavy duty, aluminium conductor. 22 kV grade armoured cable of the following sizes as required, generally conforming to IS:1554/Part- I/1970 22 kV Grade, 3Cx185Sqmm Ar, Alu.
110
-
-
Laying of one number XLPE power cable of 33 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm
60
-
-
Laying of one number XLPE power cable of 33 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
20
-
-
Laying of one number XLPE power cable of 33 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
30
-
-
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 22 KV grade as required :185 sq. mm
4
-
-
Earthing with G.I. earth pipe 2.7 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
3
-
-
Earthing with G.I. earth plate 1200 mm X 1200 mm X 10 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
6
-
-
Providing and fixing 25 mm X6 mm GI strip on surface or in recess for connections etc. as required.
300
-
-
Providing and fixing 50 mm X6 mm GI strip on surface or in recess for connections etc. as required.
180
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor 1.1 kV grade armoured MV cable of the following sizes as required, generally conforming to IS:70983.5Cx300 Sqmm Ar, Al.
100
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor 1.1 kV grade armoured MV cable of the following sizes as required, generally conforming to IS:70983.5Cx50 Sqmm Ar, Al.
110
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
83
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
78
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
40
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 35 sq. mm and upto 95 sq. mm
25
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mm
39
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm
40
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
20
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
39
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
20
-
-
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
15
-
-
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
15
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 50 sq. mm (32mm)
8
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 185 sq. mm (57mm)
4
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 240 sq. mm (62mm)
4
-
-
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness
50
-
-
MP PANELSupply, Installation, Testing and Commissioning of cubical type dust & vermin proof floormounting main panel board made out of 16gauge CRC sheet metal enclosures comprisingof the Following with powder coating.Panelshould be complete with suitable heat shrinkablePVC sleeved Al Bus Bars, EarthInterconnection, R,Y,B. LED Phase indicationLamps,suitable size 1 class CTs and internal wiring etc1)EB INCOM : 630A 4P MCCB (microprocessor)1No2)outgoing : 200A 4P COS-2No3)315A 4P COS-1No4)400A 4P COS-1No5)100A 4P COS-2No6) 200A 4PMCCB (thermal magnetic)-1No7)315A 4PMCCB (thermal magnetic)-1No8) 400A 4PMCCB (thermal magnetic)-1No9)100A 4PMCCB (thermal magnetic)-2No10) Three phase CT metering facility -5nos
1
-
-
SPICE-1Supply of cubical type dust & vermin proof floormounting main panel board made out of 16gauge CRC sheet metal enclosures comprisingof the Following with powder coating.Panelshould be complete with suitable heat shrinkablePVC sleeved Al Bus Bars, Earth Interconnection, R,Y,B. LED Phase indicationLamps,suitable size 1 class CTs and internal wiring etc1)DG Incom : 400A 4P MCCB (thermalmagnetic) 1No2) 250A 4PMCCB (thermal magnetic)-2No3) 160A 4PMCCB (thermal magnetic)-1No4)R Indicator - 2nos5)Y Indicator - 2 nos6)B Indicator - 2 nos7) MFDM(V,I,F,PF) -2 nos8)20A Fuse Base - 6 nos
1
-
-
SPICE-2Supply of cubical type dust & vermin proof floormounting main panel board made out of 16gauge CRC sheet metal enclosures comprisingof the Following with powder coating.Panelshould be complete with suitable heat shrinkablePVC sleeved Al Bus Bars, Earth Interconnection, R,Y,B. LED Phase indicationLamps,suitable size 1 class CTs and internal wiring etc1)DG Incom : 315A 4P MCCB (thermalmagnetic) 1No2) 200A 4PMCCB (thermal magnetic)-1No3) 160A 4PMCCB (thermal magnetic)-2No4)R Indicator - 2nos5)Y Indicator - 2 nos6)B Indicator - 2 nos7) MFDM(V,I,F,PF) -2 nos8)20A Fuse Base - 6 nos
1
-
-
Testing and commissioning of existing MSB 2, MSB 3 and MSB 4 panels
1
-
-
50 KVAR APFC PANELSupply of cubical type dust & vermin proof floor mounting main panel board made out of 16 gauge CRC sheet metal enclosures comprisingof the Following with powder coating. Panel should be complete with suitable heat shrinkable PVC sleeved Al Bus Bars, Earth Inter connection, R,Y,B. LED Phase indication Lamps, suitable size 0 .5 class CTs and internal wiring etc1)Incomer : 125A TPN SFU ISO2)Outgoing: 16A TP MCB with 5 Kvar heavey dute capacitor 5Kvar capacitor duty contactor ON , OFF push button , ON indicator 2no 3) 20A TP MCB with 7.5 Kvar heavey dute capacitor 7.5Kvar capacitor duty contactor ON , OFF push button , ON indicator 2no 4) 25A TP MCB with 10 Kvar heavey dute capacitor 10Kvar capacitor duty contactor ON , OFF push button , ON indicator 1no 4) 40A TP MCB with 15 Kvar heavey dute capacitor 15Kvar capacitor duty contactor ON , OFF push button , ON indicator 1no
4
-
-
Supply and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to IS : 15652 - 2006 & CPRI tested having 3mm thickness up to 66kV
4
-
-
Earthing of Panel doors with new flexible wires, sockets and nuts and bolts, sealing of cable entry holes. Replacing non-standard wirings, identifying and naming each more, starter and their switches Shrouding of switches
1
-
-
Supply and fixing of 16A, 4P MCB for 3HP Gear Motor in Blender cum roaster 1 and 2
2
-
-
Supply and fixing of 160 Amps 4P MCCB towards Motor- 1(55kW) and Motor 2(45kW)
2
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor 1.1 kV grade armoured MV cable of the following sizes as required, generally conforming to IS:7098 4CX6 Sqmm Ar, Al.
13
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor 1.1 kV grade armoured MV cable of the following sizes as required, generally conforming to IS:7098 3.5Cx35 Sqmm Ar, Al.
13
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor 1.1 kV grade armoured MV cable of the following sizes as required, generally conforming to IS:7098 3.5Cx70 Sqmm Ar, Al.
8
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor 1.1 kV grade armoured MV cable of the following sizes as required, generally conforming to IS:7098 3.5Cx95 Sqmm Ar, Al.
8
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
8
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
11
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
5
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
11
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
2
-
-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm
1
-
-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 50 sq. mm
1
-
-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 70 sq. mm
1
-
-
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 95 sq. mm
1
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
180
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2+4 way, Double door
1
-
-
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate,interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/Isolator)4 way ( 4+12), Double door
1
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
5
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
10
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1
-
-
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1
-
-
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1
-
-
Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
4
-
-
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
20
-
-
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wire
20
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
20
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
10
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
5
-
-
Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
5
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
2
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
2
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
50
-
-
Civil Works
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
67.49
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
52.09
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
4.85
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
2.75
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
2.42
-
-
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
1.36
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
193.6
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
108.64
-
-
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
26.13
-
-
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
12.05
-
-
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
8.64
-
-
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
23.42
-
-
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
4.55
-
-
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
4.91
-
-
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
138.02
-
-
Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing
22.9
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
99.08
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
309.24
-
-
Providing and fixing bolts including nuts and washers complete.
3.12
-
-
Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2
29.4
-
-
Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m2
7
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
18.72
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
18.72
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
2.88
-
-
Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
8
-
-
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
8.4
-
-
Providing and fixing ball bearing for rolling shutters.
4
-
-
Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).
4.8
-
-
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm
36
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1335.79
-
-
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
68.51
-
-
Evaluation Notes How It Works ?