Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Industrial Infrastructure Development Corporation - KINFRA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date13 Sep 2024
Closing Date4 Nov 2024
Tender Amount₹ 5,54,04,675 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od94023/2024_2025 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 63mm Outer Dia with all fittings like elbows, tees, flanges, tapers, nuts bolts, and all necessary specials for the complete installation of the pumping system.

90

-

-

... More
od94024/2024_2025 : Supply of uPVC Pipe, IS 4985: 2000 , 10kg/cm2, 50 mm Outer Dia with all fittings like elbows, tees, flanges, tapers, nuts bolts, and all necessary specials for the complete installation of the pumping system.

10

-

-

... More
od49681/2024_2025 : SITC of Waste water submersible pump stainless steel 3 lps ,10 mtr head ,1 phase , 230 volt. (fire pump room drain pit)

1

-

-

... More
od49682/2024_2025 : SITC of back wash pump 5 hp, 415V, 3phase with 324 lpm at 36 meter head.65 x 65 mm Suction and discharge with required accessories<br>

2

-

-

... More
od70117/2024_2025 : Supply, installation, testing and commissioning of submersible pump, 25 cu.m/hour discharge at 40 m head with 65 mm discharge pipe diameter, with all required accessories.

4

-

-

... More
od48137/2024_2025 : Supply & Installation of Multi Port Valve 3" 6 way valve, side mount, ABS fibre glass reinforced with EPDM o-rings having a minimum working pressure 3.5 bar with all accessories.

6

-

-

... More
18.19.3.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreVertical

1

-

-

... More
od48467/2024_2025 : SITC of Chemical Dosing pump,0-50lph, 50bar diaphragm type with PVC chemical tank of 500 Liters (sintex tanks) and required Accessories

2

-

-

... More
18.19.5.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreVertical

4

-

-

... More
100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes.

10

-

-

... More
100.9.6 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 63 mm nominal outer dia pipes.

90

-

-

... More
100.55.1 : Supplying of 2 to 6 mm and 6 to 12 mm size fine pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc. complete as per CPHEEO specifications.

1.2

-

-

... More
100.55.2 : Supplying of 12 to 20mm size pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5km and labour charges for stacking, spreading, testing and as per the directions of the department officers etc complete and as per CPHEEO specification.

1.2

-

-

... More
100.55.3 : Supplying of 20 to 40 mm pebble (pebbles shall be hard, clean, free from clay, dust and other impurities), stacking in standard heaps for measurement including cost, conveyance up to 5 km and labour charges for stacking, spreading, testing and as per directions of the department officers etc. complete and as per CPHEEO specification.

1.2

-

-

... More
100.55.4 : Supplying and stacking for measurement of filter sand having effective size 0.45 to 0.70 mm and uniformity coefficient 1.30 to 1.7, of specific gravity in the range of 2.55 - 2.65 and hard and clean, free from clay, dust and other impurities including cost of materials, labour charges and conveyance of materials up to 5 km and as per the directions of the department officers etc. complete and as per CPHEEO specification.

1.78

-

-

... More
od48507/2024_2025 : Supply and intsllation silex sand for water filter 3-5mm

1680

-

-

... More
od48508/2024_2025 : Supply & Installation of activated carbon 1050 IV for ACF filter in water treatment plant

560

-

-

... More
od48723/2024_2025 : Supply & Installation of iron removal filter in water treatment plant with Catalox, granular particles having a bulk density of 2g/cum, mesh size of 0.85-2.36 mm & a specific gravity of 3.8.

1870

-

-

... More
od48235/2024_2025 : Providing and fixing of brass ball valve, screwed type, with 10 kg/sq. cm working pressure and 65 mm nominal diameter

12

-

-

... More
od48237/2024_2025 : Providing and fixing of brass ball valve with Accessories , screwed type, with 10 kg/sq. cm working pressure and 40 mm nominal diameter

1

-

-

... More
Safety & Disaster Risk Reduction Cell - Firepumps, hydrant line

-

-

-

... More
od47124/2024_2025 : "Hydrant Valve<br>Supply, installation, testing and commissioning of single headed fire hydrant valve conforming to IS:5290 and with ISI mark of 63mm dia. Oblique type with instantaneous hose coupling adaptor.kartar<br>"<br>

29

-

-

... More
od94020/2024_2025 : Supplying, installation, testing and commissioning of electric driven pressurisation pump<br>suitable for automatic operation and consisting of following, complete in all respects, as<br>required : (Jockey Pump)<br>Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with<br>stainless steel shaft, mechanical seal conforming to IS : 1520.<br>Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3<br>phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot<br>mounted type with Class-'F' insulation, conforming to IS : 325.<br>M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as<br>required.<br>Suitable cement concrete foundation duly plastered and with anti vibration pads.180 lpm at 70 m Head

2

-

-

... More
od47125/2024_2025 : "Hose Cabinet<br>Supply, Installation, testing and commissioning of hose cabinet (internal) to accommodate one piece of hose pipe along with one pair of male and female coupling and one branch pipe. The cabinet is made up of MS sheet, glass fronted with hinged door and lock. The cabinet is spray painted to scarlet red<br>colour outside and off white inside

29

-

-

... More
od47127/2024_2025 : Fire brigade inlet<br>Supply and installation of 4 way Fire brigade inlet with arrangement to directly feed water to 150mm dia. Wet riser.Make : Karthar<br>

1

-

-

... More
od47134/2024_2025 : "Fire Fighting Hose<br>Supply, installation, testing and commissioning of reinforced rubber lined hose in 15Mtrs length of 63mm dia with ISI marking and tested to bursting pressure of 15Kg/sq.cm and with couplings.fire<br>squad/AquaDura/NewAge<br>"<br>

58

-

-

... More
od47163/2024_2025 : "Branch Pipe<br>Supply, installation, testing and commissioning of gunmetal short branch pipe conforming IS:903 and with ISI mark with 63mm female hexagonal brass nozzle.()(ss metal)<br>"<br>

29

-

-

... More
od47192/2024_2025 : Supplying 4 pole 440 V Surge protection device

1

-

-

... More
od47202/2024_2025 : Pressure Gauge<br>supply and installation of dial type Pressure Gauge with required Dia 4", 0-10 kg/cm2

6

-

-

... More
od47209/2024_2025 : Pressure Switch<br>Supply and installation of Pressure Switch for automatic operation of fire pump.<br>

3

-

-

... More
od47224/2024_2025 : Hooter<br>Supply, installation, testing and<br>commissioning of hooter RAVEL<br>

2

-

-

... More
od47229/2024_2025 : AIR RELEASE VALVE<br>Supply and installation of AIR RELEASE VALVE 25 mm dia make;Karthar

4

-

-

... More
od47767/2024_2025 : Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height<br>with air release valve on top and flanged connection to riser, drain arrangement with 25 mm<br>dia gun metal wheel valve with required accessories, pressure gauge and paintingwith<br>synthetic enamel paint of approved shade as required with testing arrangement.

1

-

-

... More
od47769/2024_2025 : Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable<br>for automatic operation and consisting of following, complete in all respects, as required :<br>Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze<br>impeller with stainless steel shaft, mechanical seal conforming to IS 1520.<br>Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for<br>operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure,<br>horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.<br>M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as<br>required.<br>Suitable cement concrete foundation duly plastered with anti vibration pads-2850 lpm at 88 m Head

2

-

-

... More
od47898/2024_2025 : Supplying, installing, testing & commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following complete in all respect as required : Horizontal type, centrifugal pump of cast iron body mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2850 lpm at 70 m. head conforming to IS 1520. Suitable BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 24 /12Volts electric starting equipment, diesel tank, exhaust pipe extended upto 1m. outside pump house duly insulated with 50mm thick glass wool with 1.0mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. with all accessories.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. - 2850 lpm at 70 m Head

1

-

-

... More
od47899/2024_2025 : Providing laying, testing & commissioning of 200 mm dia 'C' class heavy duty MS Pipe conforming to IS<br>1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground<br>including welding, excavation & providing cement concrete blocks as supports, anticorrosive<br>treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc.<br>complete as required

972

-

-

... More
od47917/2024_2025 : Providing laying, testing & commissioning of 100 mm dia 'C' class heavy duty MS Pipe conforming to IS<br>1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground<br>including welding, excavation & providing cement concrete blocks as supports, anticorrosive<br>treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc.<br>complete as required

335

-

-

... More
od47918/2024_2025 : Providing laying, testing & commissioning of 150 mm dia 'C' class heavy duty MS Pipe conforming to IS<br>1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground<br>including welding, excavation & providing cement concrete blocks as supports, anticorrosive<br>treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc.<br>complete as required

1460

-

-

... More
od47932/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :250 mm

6

-

-

... More
od47951/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :200 mm

20

-

-

... More
od47978/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :150 mm

35

-

-

... More
od62555/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :125 mm

6

-

-

... More
od47992/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :100 mm

86

-

-

... More
od48026/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :65 mm

10

-

-

... More
od61666/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :50 mm

29

-

-

... More
od48142/2024_2025 : Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS<br>3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets<br>etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with<br>two or more coats of synthetic enamel paint of required shade complete as required :25 mm

15

-

-

... More
od48859/2024_2025 : Supplying, fixing, testing & commissioning of double<br>flanged sluice valve of rating PN 1.6 with non rising<br>spindle, bronze/gun metal seat, ISI marked complete<br>with nuts, bolts, washers, gaskets and conforming to IS<br>780 of following sizes as required :50 mm

31

-

-

... More
od48860/2024_2025 : Supplying, fixing, testing & commissioning of double<br>flanged sluice valve of rating PN 1.6 with non rising<br>spindle, bronze/gun metal seat, ISI marked complete<br>with nuts, bolts, washers, gaskets and conforming to IS<br>780 of following sizes as required :65 mm

2

-

-

... More
od58726/2024_2025 : Supplying, fixing, testing & commissioning of double<br>flanged sluice valve of rating PN 1.6 with non rising<br>spindle, bronze/gun metal seat, ISI marked complete<br>with nuts, bolts, washers, gaskets and conforming to IS<br>780 of following sizes as required :100 mm

3

-

-

... More
od58751/2024_2025 : Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6<br>with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts,<br>washers, gaskets and conforming to IS 780 of following sizes as required :125 mm

3

-

-

... More
od48861/2024_2025 : Supplying, fixing, testing & commissioning of double<br>flanged sluice valve of rating PN 1.6 with non rising<br>spindle, bronze/gun metal seat, ISI marked complete<br>with nuts, bolts, washers, gaskets and conforming to IS<br>780 of following sizes as required :150 mm

10

-

-

... More
od48862/2024_2025 : Supplying, fixing, testing & commissioning of double<br>flanged sluice valve of rating PN 1.6 with non rising<br>spindle, bronze/gun metal seat, ISI marked complete<br>with nuts, bolts, washers, gaskets and conforming to IS<br>780 of following sizes as required :200 mm

2

-

-

... More
od65638/2024_2025 : Supplying, fixing, testing & commissioning of flanged single arch rubber expansion bellow with minimum operating pressure of 16 kg/cm2 of following size with all accessories - 150 mm NB

1

-

-

... More
od65639/2024_2025 : Supplying, fixing, testing & commissioning of flanged single arch rubber expansion bellow with minimum operating pressure of 16 kg/cm2 of following size with all accessories - 125mm NB

3

-

-

... More
od65640/2024_2025 : Supplying, fixing, testing & commissioning of flanged single arch rubber expansion bellow with minimum operating pressure of 16 kg/cm2 of following size with all accessories - 100 mm NB

2

-

-

... More
16.7.3.2 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 150 mm dia

1

-

-

... More
16.7.3.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 125 mm dia

1

-

-

... More
16.7.3.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE 100 mm dia

3

-

-

... More
16.7.3.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE of 65 mm dia

2

-

-

... More
16.7.4.2 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 150 mm dia

1

-

-

... More
16.7.4.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 125 mm dia

2

-

-

... More
16.7.4.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 65 mm dia

2

-

-

... More
od118260/2024_2025 : Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical<br>construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with<br>hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment<br>process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having<br>switch gears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in<br>all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD<br>specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac<br> Supply with enclosure protection class IP 42 as required: <br><br> Incomings 250A, 50kA 4 Pole isolator,<br>Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector<br>swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper<br>Bus Bar 400Amps Outgoings (Note: All outgoing feeders for pumps should have digital Ammeter<br>with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pumps 200 Amp,<br>50kA 4P isolator s, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump, complete with all accessories and internal wiring required for automatic operation, selector switches for local/remote, auto/manual/OFF operation. - 2 sets.<br><br> For Jockey Pump 32 Amp, 50kA 4P isolator, Ics=100% Icu, with Suitable HP fully automatic DOL starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets.<br><br> Diesel Engine Control panel for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification.<br>

1

-

-

... More
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm

40

-

-

... More
90.12.5.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm

25

-

-

... More
90.12.41.7 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp

50

-

-

... More
90.12.41.10 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 35 sq mm with factory made clamp

40

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

10

-

-

... More
od49017/2024_2025 : Supply and making end termination with brass compression gland and copper lugs of following size of PVC insulated and PVC sheathed/ XLPE cable with copper conductor of 1.1 kV grade as required - 3C x 1.5 sqmm

10

-

-

... More
od49045/2024_2025 : Supply and laying of PVC insulated PVC sheathed armoured cable with copper conductor including laying through trench, cable tray, wall of following size 1.5 sqmm 3 core PVC / XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part If for XLPE

130

-

-

... More
9.1.10 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 35 sq. mm (28mm)

8

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

4

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)

125

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

24

-

-

... More
od49146/2024_2025 : Supplying, fixing, testing & commissioning of 25mm Air release valve as per IS:14845 ISI Marked, with forged brass ball valve etc with all accessories.

4

-

-

... More
4.6.8 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.300 mm width X 62.5 mm depth X 2.0 mm thickness

15

-

-

... More
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

8

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

21

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

2

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

2

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

2

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

1

-

-

... More
1.54.2 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B

7

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

6

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
od91864/2024_2025 : Supply and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering - 2.5 sqmm 6 core Copper

650

-

-

... More
od89550/2024_2025 : Supply of 450 mm sweep, 900 rpm Heavy Duty Exhaust fan working on 230 V A/C

1

-

-

... More
od87796/2024_2025 : Supply, installation, testing, commissioning of LED Tube Lights of 20W (+/- 10% Tolerance) with Aluminum Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above including all necessary accessories as required for the light fixture

13

-

-

... More
od91309/2024_2025 : Supply and installation of SMC water meter box 65x35x30 cm

28

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

1

-

-

... More
od118269/2024_2025 : Supply, Installation, Testing and Commissioning of 1200 mm sweep,<br>BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)<br>Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2<br>nos. canopies, shackle kit, safety rope, copper winding, Power Factor<br>not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery<br>minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),<br>THD less than 10%, remote or electronic regulator unit for speed<br>control and all remaining accessories including safety pin, nut bolts,<br>washers, temperature rise=75 degree C (max.), insulation resistance<br>more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC<br>Supply, earthing etc. complete as required.

1

-

-

... More
od94356/2024_2025 : Supplying, fixing, testing & commissioning of double flanged water meter- 50mm cast iron ISI marked complete with nuts, bolts, washers, gaskets as required .(DSR 18.60.1)

28

-

-

... More
Safety & Disaster risk reduction cell WTP - Electrical

-

-

-

... More
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm

40

-

-

... More
90.12.6.14 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3 core 10 sq mm

100

-

-

... More
90.12.6.31 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 95 sq mm

20

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

14

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

2

-

-

... More
5.19 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

240

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)

20

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm(10 SWG)

4

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

2

-

-

... More
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

22

-

-

... More
od51953/2024_2025 : Supply, installation , testing and commissioning of totally enclosed compartmentalized dust and vermin proof cubical segregated and modular in construction M.V. panel board (WTP panel )free standing fabricated with14 swg of CRCA M.S. sheet, powder coated , bus-bar chamber ,outgoing switchgear etc. (all feeder unit Would be compartmentalized), color coded PVC sleeved vertical / horizontal Aluminium busbar of required size of length, (bus-bar distances shall be minimum 32 mm ) insulators, hardware, neoprene gasket , hinged door, interconnecting single core multi strand lugged copper wire having required current density ,160 Amps 4p Isolator-1no,Aluminium Busbar of minimum 200A rating ,RYB indicators one each, V&A meter-1 No each, CT 150/5- 3 nos,15VA, CL-1 , Multi function digital meter etc as required , 40A 3pole MCCB-6 no, 16A 3pole MCB-2 no, 25A A 3P MCB -1 Nos, with DOL starter for 2.25kW pumps - 1no, 7.5 kW pumps - 6 nos, single phase preventor, pump selector, level controllers, auto/manual selector etc.(ref: dwg)

1

-

-

... More
od70179/2024_2025 : upply, installation , testing and commissioning of Metering Panel with provision of 3 phase CT operated energy meter CTs etc in totally enclosed compartmentalized dust and vermin proof cubical segregated and modular in construction free standing fabricated with14 swg of CRCA M.S. sheet, powder coated , bus-bar chamber ,outgoing switchgear etc. (all feeder unit Would be Compartmentalized), color coded PVC sleeved vertical / horizontal Aluminium busbar of required size of length, (bus-bar distances shall be minimum 32 mm ) insulators, hardware, neoprene gasket , hinged door, interconnecting single core multi strand lugged copper wire having required current density ,250 Amps 4p Isolator-1no,Aluminium Busbar of minimum 250A rating ,RYB indicators one each, V&A meter-1 No each, CT 250/5- 3 nos,15VA, CL-1 , Multi function digital meter etc as required , Outgoing 125A 3pole MCCB - 1 no & 200 A 3P isolator . Rate shall be inclusive of three energy meter, CT etc (ref: dwg)

1

-

-

... More
90.6.6.3 : Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes. 4 sqmm

28

-

-

... More
od70910/2024_2025 : Supply and termination of Aerial Bunched Cable of size 3x95 + 1x70 sq mm at LT supply pole including all accessories.

2

-

-

... More
od71100/2024_2025 : Supplying and termination of AB cable in panel using copper crimping sockets and pvc cable gland for size 3x95 sqmm+1x 70 sqmm

2

-

-

... More
od70911/2024_2025 : Supply and installation of 3 core 1100V Aerial Bunched Cable having with black weather resistant XLPE insulated Cable with stranded compact circular aluminium conductors twisted over an insulated aluminium alloy messenger wire for use as neutral conductors 3x95 + 1x70 sq mm

80

-

-

... More
od87796/2024_2025 : Supply, installation, testing, commissioning of LED Tube Lights of 20W (+/- 10% Tolerance) with Aluminum Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor >0.9,THD<10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above including all necessary accessories as required for the light fixture

10

-

-

... More
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A

7

-

-

... More
1.54.2 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B

4

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

20

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

20

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

1

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

3

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

3

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

3

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

4

-

-

... More
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

2

-

-

... More
od118269/2024_2025 : Supply, Installation, Testing and Commissioning of 1200 mm sweep,<br>BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)<br>Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2<br>nos. canopies, shackle kit, safety rope, copper winding, Power Factor<br>not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery<br>minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),<br>THD less than 10%, remote or electronic regulator unit for speed<br>control and all remaining accessories including safety pin, nut bolts,<br>washers, temperature rise=75 degree C (max.), insulation resistance<br>more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC<br>Supply, earthing etc. complete as required.

1

-

-

... More
Common renewable energy generation and Street light system

-

-

-

... More
90.12.1.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core10 sq mm

4458

-

-

... More
90.12.1.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core25 sq mm

2115

-

-

... More
90.15.3.1 : Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters

6

-

-

... More
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

125

-

-

... More
11.3.1 : Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre

6

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

245

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

16

-

-

... More
2.5.1 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door

4

-

-

... More
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral

120

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

10

-

-

... More
od51206/2024_2025 : Supply & installation of whetherproof outdoor termination 185 x 165 x 60 mm with dinrail, Connectwell 50A terminal block for termination for street light pole with 16A 2P MCB light fitting Isolation

119

-

-

... More
od74865/2024_2025 : Supply installation, testing and commissioning of outdoor feeder pillar enclosure (700x480x210 mm) as per approved list of makes. The feeder pillar shall be IP-65 rated, dust and vermin proof, weather proof construction,UV resistant, halogen free and anti corrosive in accordance with IEC 61439-3, fixing on feeder pillar on frame made with angles and flats, painting with two coat of primer and epoxy paint on proper concrete foundation etc as directed.

10

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

14

-

-

... More
5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.

16

-

-

... More
5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

3500

-

-

... More
15.4.3 : Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required3 output (1output per phase) and suitable for three phase supply

11

-

-

... More
90.12.2.40 : Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including widening the trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil) 4 core 10 sq mm

1275

-

-

... More
od89596/2024_2025 : Supply installation and testing and commissioning of 40 A, 3 pole power Contactors (For 25 HP motor), AC 3 rating at 415 V,<br>with AC Coil, Auxiliary contacts, 1 NO/INC with all required accessories.

10

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

16

-

-

... More
Safety & Disaster Risk Reduction Cell - Installation of CCTV

-

-

-

... More
11.3.1 : Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre

11

-

-

... More
90.15.3.1 : Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters

11

-

-

... More
14.4 : Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.

691.2

-

-

... More
14.15.1 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)

2304

-

-

... More
od52335/2024_2025 : Supply and laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing dwc pipe as required - 2.5 sqmm 3 core PVC / XLPE insulated armoured copper cables

480

-

-

... More
od65945/2024_2025 : Supply & installation for 4F Armoured Optical Fiber Cable ,Single Mode, 9/125 micron primary coated buffers Corrugated Steel Tape Armour Bellcore GR 20 / IEC 794-1 through existing DWC pipes including splicing etc

3881

-

-

... More
od65946/2024_2025 : Supply and making end termination with brass compression gland and copper lugs of following size of PVC insulated and PVC sheathed/ XLPE cable with copper conductor of 1.1 kV grade as required - 3C x 2.5 sqmm

14

-

-

... More
od52385/2024_2025 : Supply and laying CAT 6 UTP 23 awg copper cable twisted pair, GI armoured cable through dwc pipes including termination cable.

993

-

-

... More
od57808/2024_2025 : Supplying 4MP fixed IP Outdoor Camera , including all material, labour, transportaion & installation charges( HikVision DS-2CD206WFWD-1)

16

-

-

... More
od58626/2024_2025 : Supply installation of Gigabit Multi-Mode RJ 45 to fibre Media Converter

14

-

-

... More
od68467/2024_2025 : Supply, installation testing and commissioning of 16 Port Gigabit Unmanaged POE Switch IEEE 802.3, IEEE 802.3u, and IEEE 802.3x standard with 6 KV surge protection for PoE ports etc will all accessories.

1

-

-

... More
od68755/2024_2025 : Supply installation of pole mounted IP65 outdoor water proof feeder pillar for installation of CCTV POE switch accessories etc with provision for power supply etc inculding the support and foundation etc

7

-

-

... More
od66939/2024_2025 : Supply and Installation of Cat6 patch cord with RJ45 male connectors at ends - 2m

7

-

-

... More
od66985/2024_2025 : Supply and Installation of Cat6 patch cord with RJ45 male connectors at ends - 1m

14

-

-

... More
od58898/2024_2025 : Supply installation of outdoor 8 port 1000/1000Mbps RJ45 PoE Ports switch in IP65 weather proof enclosure accessories etc as directed.

7

-

-

... More
od58998/2024_2025 : Suplply and installation of Monitor - LED 75Hz 55" 1920x1080 Pixels FHD Resolution Monitor with HDMI + VGA inputs.

1

-

-

... More
od58999/2024_2025 : Network rack - floor standing 20" 26U rack with cooling fan, power distribution unit, tray, cable management unit etc with all other accessories

1

-

-

... More
od66376/2024_2025 : Supply installation testing & commissioning of 32 Channel Metal 4 SATA 4K NVR, H.265+/H.265/H.264+/H.264 video format, with HDMI and VGA interfaces: both interfaces support independent video output, 10TB HDD 2 number for continuous video recording, 2 self-adaptive 10/100/1000 Mbps Ethernet interfaces (Hikvision DS-7732NI-K4)

1

-

-

... More
Civil Works - Boundary Fencing work

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

30.87

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

1.52

-

-

... More
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

5160

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

5.45

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

28.51

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

531.02

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

21.48

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

18

-

-

... More
15.34.2 : Dismantling and stacking with in 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of :R.C.C.

29

-

-

... More
15.36 : Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead.

932.13

-

-

... More
16.15.1 : Supplying at site:R.C.C. Standards post / struts / rails / pales of mix 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 12.5 mm nominal size ) with wooden plugs or 6 mm bar nibs wherever required as per direction of Engineer-in-Charge (cost of earth works in excavation, concrete works in foundation to be paid separately)

1.05

-

-

... More
16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade

540

-

-

... More
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site

34.9

-

-

... More
60.7.3 : DISMANTLING DR - Dismanling , clearing away and carefully stacking materials useful for reuse for any thickness of walls in DR masonry including disposal of debris within a distance of 150m.

16.11

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

16.16

-

-

... More
16.17.1 : Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I staples on wooden plugs or G.I binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used .With G.I barbed wire

20331

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

8.18

-

-

... More
60.7.9 : RR with Departmental. Stone - Random rubble masonry using departmental rubble in foundation and plinth including through and bond stone and levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).

30.01

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

6.81

-

-

... More
15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)

0.11

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

0.5

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

0.03

-

-

... More
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

0.24

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

4.68

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

0.33

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

0.29

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

0.62

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

3.3

-

-

... More
13.2.1 : 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4 (1 cement :4 fine sand)

2.84

-

-

... More
100.98.23 : Supply of PVC Coupling 90mm, 8 kg/cm2

2

-

-

... More
100.9.2 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 25 mm nominal outer dia pipes.

2

-

-

... More
Water supply including overhead tanks and pump house

-

-

-

... More
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

1218.02

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

1215.44

-

-

... More
13.82.2 : Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two coats

687.83

-

-

... More
13.111.2 : Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (One or more coat applied @ 0.90 ltr/10 sqm).

527.62

-

-

... More
14.7.1 : Renewing glass panes and re fixing existing wooden fillets:Float glass panes of thickness 4 mm

1.08

-

-

... More
2.10.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc, not exceeding 80 mm dia

291

-

-

... More
Safety & Disaster Risk Reduction Cell Rain water harvest for fire and safety water storage

-

-

-

... More
od57375/2024_2025 : Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 3 X 1.5 sq. mm

2

-

-

... More
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm

60

-

-

... More
90.12.1.13 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm

30

-

-

... More
90.12.1.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 25 sq mm

30

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

2

-

-

... More
5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

80

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

2

-

-

... More
90.6.6.3 : Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm

20

-

-

... More
Safety & Disaster Risk Reduction Cell Rain water harvest for fire and safety water storage - Plumbing

-

-

-

... More
od57736/2024_2025 : SITC of Three phase wall mounted Starter panel for new pumps in well (1 working+1 stand-by) Incomer 100A,4P isolator - 1 no, Outgoing 40A,3P MCCB, with suitable rated contactor, OLR etc. for the star / delta control for 18 HP submersible pumps - 2nos : phase indicators, single phase preventer, level controllers, pump selector etc.

1

-

-

... More
od57737/2024_2025 : Supply and providing 5 meter length float switch for level control<br>

2

-

-

... More
od57738/2024_2025 : Providing and fixing S S Slotted rail<br>

350

-

-

... More
od57739/2024_2025 : Providing and fixing Brass ball valve of approved quality 80 mm nominal bore<br>

2

-

-

... More
od57740/2024_2025 : Supply , installation ,testing and commissioning of SS Hose collar and clip 80 mm

4

-

-

... More
od57741/2024_2025 : SITC of Submersible pump 385 LPM@ 105 M head 80mm .

2

-

-

... More
18.19.6.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreVertical

2

-

-

... More
100.98.194 : Supply of PE Pipe, PE100, PN16, 90mm dia, conforming to IS 4984/2016.

840

-

-

... More
od58997/2024_2025 : Supply and Providing 110mm dia 6kg pvc pipe with bend 3.00 mtr covering around concrete 30 cm x 30 for HDPE pipes installation

6

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

1050

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

0.33

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

0.29

-

-

... More
4.1.2 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)

0.03

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

0.08

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

0.2

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

56.06

-

-

... More
100.98.202 : Supply of PE Pipe, PE100, PN16, 250mm dia, conforming to IS 4984/2016.

15

-

-

... More
16.70.1 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I. wire of dia 4 mm

2

-

-

... More
Common Effluent Treatment plant - Emergency supply

-

-

-

... More
5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.

4

-

-

... More
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

1

-

-

... More
90.12.1.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core25 sq mm

12.5

-

-

... More
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp

24

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

6

-

-

... More
od71237/2024_2025 : Supply installation testing and commissioning of three phase, 415V, 50Hz, 0.8pf 25 kVA diesel generator with standard control panel and earth fault relay in weatherproof accoustic enclosure.

1

-

-

... More
od72406/2024_2025 : Supply installation of surge arrestor Type 1+2, 12.5 kVA, 3P+N configuration, Conforming to IEC 61643-11 in existing ETP SSB including connections etc as directed.

1

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)

65

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor ( 8 SWG)

10.5

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

18

-

-

... More
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

4

-

-

... More
od71320/2024_2025 : Supply installation of 63A, 415V, 4 pole automatic transfer switch with Automatic start/stop operation of DG on mains failure including enclosure etc with accessories

1

-

-

... More
6.12 : Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

2

-

-

... More
6.7 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

12

-

-

... More
6.8 : Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

35

-

-

... More
6.2 : Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

2

-

-

... More
od72824/2024_2025 : Supplying and fixing of medium class G.I. pipe of 50 mm dia. (nominal) 3 metres length with base plate etc for fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top with pipe painted with HR aluminium paint etc as required.

2

-

-

... More
Common Renewable Energy Generation (Solar)

-

-

-

... More
od119062/2024_2025 : Supply, Installation, Testing and Commissioning of on grid Solar Photovoltaic<br>Power Plant conforming to MNRE specifications as amended, consisting of Mono<br>Crystalline silicon sola rcells, net metering facility, necessary protections, earthing,<br>mounted on Aluminium/ GI structure of suitable strength with following<br>components complete as required:- a)Solar Photovoltaic Module of<br>capacity 530-560Wp or above, manufactured in India, conforming to IS14286/<br>IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module<br>conversion efficiency shall not be less than 16.5%. PV modules used in solar<br>power plants/ systems must be warranted for their output peak watt capacity,<br>which should not be less than 90% at the end of 10 years and 80% at the end of<br>25 years.<br>b)Power Conditioning Uni t(PCU) of 350-800 VDC Input voltage<br>range and 400VAC, three phase, 4wire, 50Hz+/-2.5Hz, output voltage suitable to<br>generate AC Power with efficiency not less than 97%, total harmonic distortion<br>less than 3% and suitable for ambient temperature from 0 to 50 degree C. The<br>PCU shall adjust the voltage and frequency level to suit the Grid Voltage<br>F r e q u e n c y . c ) D a t a M o n i t o r i n g S y s t e m c o m p l e t e w i t h<br>accessories.d)Fixing of Array junction box & Main junction box with IP65<br>protection and termination arrangement for incoming and outgoing cable along<br>with lands, lugs and other accessories etc. as required.e)Lightning and surge<br>voltage protection.f)Connections & Interconnections by supplying & fixing<br>required size XLPE insulated copper conductor 1.1kV grade armoured power and<br>control cables between solar modules, main power cable to grid supply PCU unit<br>along with supplying & fixing of necessary channel/ conduit lugs and other<br>accessories etc. as required

100

-

-

... More
Common Effluent Treatment plant - Civil Works

-

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

1

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

1

-

-

... More
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

0.68

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

40.5

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

1.35

-

-

... More
12.1.2 : Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2

19.25

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

135.47

-

-

... More
Laying of roads - Food zone road

-

-

-

... More
4.12 : Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

840

-

-

... More
5.1.a : Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.

5600

-

-

... More
5.2.a : Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.

11200

-

-

... More
5.4.2b : Dense Graded Bituminous Macadam : - For grading - II (26.5 mm nominal size) br Providing and laying dense graded bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (VG 30) @ 4.0 to 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.

280

-

-

... More
5.6.2.b : Providing and laying bituminous concrete with 100-120 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (NRMB) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects br For Grading -II (13.2 mm Nominal size). br

168

-

-

... More
3.15 : Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres by Mechanical Means br

39200

-

-

... More
4.1.A.1 : Construction of granular sub-base by providing graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 br Grading-I - Plant Mix Method

840

-

-

... More
5.2.b : Providing and applying tack coat with bitumen emulsion (RS) using emulsion pressure distributor at the rate of 0.25 - 0.30 kg per sqm on the prepared Granular Surface cleaned with mechanical broom.

5600

-

-

... More
Safety & Disaster Risk Reduction Cell Fire tank

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

105.07

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

15039.42

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

69.31

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

186.16

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

91.65

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

1.2

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

2.52

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

6261.25

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

38.82

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

38.97

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

744.1

-

-

... More
13.40 : Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:

172.2

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

241.27

-

-

... More
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

113.02

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

5.04

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
10.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes

12.67

-

-

... More
13.48.3 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

0.93

-

-

... More
6.4.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand)

18.07

-

-

... More
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

0.22

-

-

... More
50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood

1.78

-

-

... More
50.9.6.1 : Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters

4.41

-

-

... More
13.48.2 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture

10.15

-

-

... More
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

68.4

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

0.11

-

-

... More
od79770/2024_2025 : Supply and instllation of FRP manhole cover and frame Light Duty (5 MT) with closed bottom lifting key holes & load tested as per IS:1726 & BS EN:124."600 X 600 mm (24"" X 24"") inside using self pigmented type double seal.

2

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

10.4

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

5.2

-

-

... More
Safety &amp; Disaster risk Reduction Cell- Rain Water Harvesting

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

177.48

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

290.4

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

467.88

-

-

... More
4.1.4 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

12.24

-

-

... More
16.94 : Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ? 2%) Zinc coated, Mesh wire diameter 3.0 mm, mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2mm, supplied @ 3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per direction of Engineer-in-charge.

100.98

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

68

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

7762.9

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

9.18

-

-

... More
16.1 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

408

-

-

... More
60.2.2 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete

200

-

-

... More
Safety & Disaster risk Reduction Cell - WTP

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

189.31

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

44.66

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

93.98

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .

50

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

13.17

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

160.08

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

63.52

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

5.76

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

10461.73

-

-

... More
5.34.1 : Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).

65.06

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

68.66

-

-

... More
14.91.1 : Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with nonwoven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25 degree, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23 degree as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150 degree. Cold flexibility shall be upto -2degree when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick

95.04

-

-

... More
13.40 : Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:

131.8

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

134.88

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

470.6

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

4.8

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
13.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .

12.48

-

-

... More
6.4.1 : Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:Cement mortar 1:4 ( 1 cement : 4 coarse sand)

16.68

-

-

... More
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood

0.13

-

-

... More
50.9.3.1 : Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood

2.88

-

-

... More
50.9.6.1 : Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters

2.88

-

-

... More
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding

45.21

-

-

... More
od79770/2024_2025 : Supply and instllation of FRP manhole cover and frame Light Duty (5 MT) with closed bottom lifting key holes & load tested as per IS:1726 & BS EN:124."600 X 600 mm (24"" X 24"") inside using self pigmented type double seal.

2

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

8.28

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

4.14

-

-

... More
Laying Drainage for Main Road

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

297.9

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

900

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

4.51

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

340.76

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

53.49

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

3980.64

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

442.16

-

-

... More
13.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .

603.8

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

32.44

-

-

... More
19.6.5 : Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete:450 mm dia R.C.C. pipe

510

-

-

... More
od111271/2024_2025 : Supply installtionof 150x150mm CI grating in kerb including cutting of kerb, installing 110mm, 10kg/cm2<br>PVC pipe connecting it to drain of 450mm RCC drain pipe including all accessories as directed.

26

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

26.91

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.