Kerala Industrial Infrastructure Development Corporation Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Industrial Infrastructure Development Corporation - KINFRA Tender

Works
Eprocure
Opening Date27 Aug 2021
Closing Date22 Sep 2021
Tender Amount₹ 9,43,97,404 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od172812/2020_2021 : Providing and fixing ISI marked C.I. D/F sluice valves of 1200 mm dia with spur gear as per IS 14846:2000 extended spindle with approx. length of 8.5m,plummer blocks at 1.5 m intervals, head stock and wheel complete with all accessories for upper level

1

-

-

... More
od172813/2020_2021 : Providing and fixing IS marked C.I. D/F sluice valves of 1200 mm dia with spur gear as per IS 14846:2000 with extended spindle with approx. length of 10 m,plummer blocks at 1.5 m intervals, head stock, wheel complete with all accessories for middle level

1

-

-

... More
od172814/2020_2021 : Providing and fixing ISI marked C.I. D/F sluice valves of 1200 mm dia with spur gear as per IS 14846: 2000 with extended spindle with approx. length of 12m,plummer blocks at 1.5 m intervals, head stock, wheel complete with all accessories for lower level

1

-

-

... More
od172815/2020_2021 :Supplying fixing of ISI marked CI non return valve, PN 1.6 rating flanged type as per IS 5312, internal parts SS in the DI lines including necessary specials, etc. - 300mm(single door)

4

-

-

... More
od172816/2020_2021 : Supplying fixing of ISI marked CI non return valve, PN 1.6 rating flanged type as per IS 5312, internal parts SS in the DI lines including necessary specials, etc. - 800mm(Multi door)

1

-

-

... More
od172824/2020_2021 : Supplying, handling, welding, fixing and painting of pipe line manifold using 800 mm size, 8 mm thick MS pipe of 8 m (approx.) length, as main header and 300 mm pipe as branch header using MS pipe of 8mm thick, complete with specials such as tees, elbows, bends, Class D flanges, checknuts, tail,pieces, clamps, supports, etc. complete

1

-

-

... More
od172826/2020_2021 : Supplying, fixing and commissioning of vertical turbine self lubricating pump suitable for a well depth of approx. 20.5 m metre with CI bowl, bronze impeller, MS ERW / CI flanged column pipes not exceeding 2 m length, SS-410 pump and line shafts, rubber coupling and bearing, MS fastners, strainer coupled with squirrel cage vertical hollow shaft motor, 1500 rpm, working with 415 V, 3 pH, 50 Hz including base plate foundation bolts, nuts, pressure gauge and all accessories. Capacity :708 cum/hr individually, gives 2124 cum/hr when 3 pumps are working in parallel against a total head of 69 m and gives 1416cum/hr when 2 pumps are working in parallel against a total head of 59m

4

-

-

... More
od172827/2020_2021 : Supplying and fixing of 5 ton capacity HOT crane with chain pulley block suitable for 6 m lift, 9-10 m span (approx.) with circular rail and complete with all accessories, etc.

1

-

-

... More
od172828/2020_2021 : Supplying and fixing of water level indicator, ultra sonic type with a measuring range of 15 metre, 2 wire type, with 3",ANSI, 150 #PP flanged connection with PP/PVDF sensor material, aluminium housing material, weather proof, IP65, suitable for temperature ranging from -10o C to 80oC, accuracy + 0.25% with 6 digit LCD display and including all accessories.

1

-

-

... More
od172831/2020_2021 : Supplying and fixing D/F DI pipe of 1200 mm dia and 1.25 m length with puddle flange and flanged bell mouth of 1200 mm dia

3

-

-

... More
Earth work

-

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

974

-

-

... More
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

150

-

-

... More
2.16.1 : Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m

26.1

-

-

... More
2.16.2 : Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m

26.1

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

420.64

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

269.04

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

392.85

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

110.62

-

-

... More
50.2.3.1 : Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete

100

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

80.47

-

-

... More
od27221/2020_2021 : Filling with available earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.

172.19

-

-

... More
od314154/2019_2020 : Providing and constructing coffer dam having top width 1m and bottom width of 2m,with an average height of 3m from bed level, using half split coconut piles of 5m length driven at 1m c/c on both sides, screening with double layer of bamboo matting on either side keeping cross ties and horizontal supports using 1/3 split coconut, tying with G.I wire and coir filling inside, with clay cut and conveyed, maintaining the bund and removal of bund after completion of work etc complete as directed by the Engineer-in-charge.

31

-

-

... More
od315449/2019_2020 : Supplying and filling in plinth or trenches, under floors, foundations, in areas ,inside the well etc. with quarry sand including watering, ramming consolidating and dressing, cost and conveyance of all materials,labour charges,lead,lift etc complete at all levels as directed by the Engineer- in-Charge

410.56

-

-

... More
od27211/2020_2021 : Soling with soling stone of size 150 to 75 mm brokenstone and blinding materials, including hand packing and wedging them tightly so that the whole is formed as a solid mass, spreading blinding material in 12mm thick layers and sweeping the same to fill the voids,watering profusely and consolidating with hand rammer/ plate vibrator etc complete as per the direction of Engineer-in - Charge.

57.26

-

-

... More
od315465/2019_2020 : Deepening the intake well mouth mouth by using dredger having a flow rate of 700 to 1000m3 slurry per hour with a solid output of not less than 127.5 m3/hour and dumping the spoil at location already pointed out by the departmental officers with a lead up to a radial distance of 500m, including hire charges of dredger, all tools and plants and accesories , fuel charges, idling and mobilisation charges, providing and shifting the pipe lines including all labour charges, incidental charges etc. complete for a depth upto (-) 4.50m bed level with a tolerance of +/- 20cm.

184.8

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

630.1

-

-

... More
od107606/2020_2021 : Carriage of materials by mechanical transport including loading,unloading and stacking beyond 50 m initial lead up to 1km, including all lifts involved as directed by the Engineer-in-Charge.Excavated Earth/ rock.

46.48

-

-

... More
Well Sinking (MoRTH Items)

-

-

-

... More
od314726/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Clayey Soil , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth below bed level upto 3.0 M

3

-

-

... More
od314727/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Sandy Soil, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Beyond 3m upto 10m depth

7

-

-

... More
od314725/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Sandy Soil, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 11th meter

1

-

-

... More
od314724/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Sandy Soil, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 12th meter

1

-

-

... More
od314722/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Sandy Soil, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. depth - 13th meter

1

-

-

... More
od314723/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Sandy Soil, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 14th meter

1

-

-

... More
od314721/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Sandy Soil, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 15th meter

1

-

-

... More
od314720/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Clayey Soil , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. depth - 16th meter

1

-

-

... More
od314719/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Clayey Soil , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 17th meter

1

-

-

... More
od314718/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Clayey Soil , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 18th meter

1

-

-

... More
od314717/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Clayey Soil , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 19th meter

1

-

-

... More
od314716/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Clayey Soil , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 20th meter

1

-

-

... More
od314715/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Clayey Soil , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 21st meter

1

-

-

... More
od314714/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Clayey Soil , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth - 22nd meter

1

-

-

... More
od314713/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Soft Rock , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth in soft rock strata upto 3m ( Beyond 22nd Meter)

1.15

-

-

... More
od314712/2019_2020 : Sinking of 11.6 m external diameter well ( other than pneumatic method of sinking ) through Hard Rock , complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. Depth in hard rock strata upto 3 m( Beyond 23rd Meter)

0.6

-

-

... More
Concrete Work

-

-

-

... More
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

32.37

-

-

... More
4.1.5 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

1.14

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

54.63

-

-

... More
4.2.3 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

5.61

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

0.68

-

-

... More
4.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

4

-

-

... More
4.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification . ( Note : Quantity of cement used in respective item shall be measured for payment . Dosage of water proofing compound shall be 1 kg per bag of cement or as per Manufacturer's recommendation.)

30946.5

-

-

... More
4.13 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

4

-

-

... More
Pile and R.C.C Works

-

-

-

... More
od106604/2020_2021 : Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).(Note: Minimum cement content considered in M-30 is @ 400 Kg/cum as per IS 2911 : 2010.Additional cement requirement as per mix design shall be considered by the bidder while quoting .Nothing extra shall be paid on this account). 500 mm dia piles

514.5

-

-

... More
20.6.2.1 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacity. Initial test

1

-

-

... More
20.6.2.2 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacity. Routine test

1

-

-

... More
od5431/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.Nothing extra shall be paid on this account). All work upto plinth level

1146.29

-

-

... More
od5432/2020_2021 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.Nothing extra shall be paid on this account). All work above plinth level upto floor V level

220.98

-

-

... More
od107608/2020_2021 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.(Note :- Minimum Cement content considered in this item is @ 330 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.Nothing extra shall be paid on this account)

1.2

-

-

... More
od28878/2020_2021 : Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/RMC.(Note :- Minimum Cement content consideredin M-30 is @ 340 kg/cum. Additional cement requirement as per mix design shall be considered by the bidder while quoting.Nothing extra shall be paid on this account)

1157.14

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

160349.94

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

30915.49

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

218.68

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

2699.61

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

871.35

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

973.06

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

257.76

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

31.52

-

-

... More
5.9.15 : Centering and shuttering including strutting, etc. and removal of form for:Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like

100.2

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

303.13

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

93.34

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

3107.18

-

-

... More
od314142/2019_2020 : Extra for circular work -Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1854.99

-

-

... More
od314155/2019_2020 : Extra for circular work -Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers

76.4

-

-

... More
od314156/2019_2020 : Extra for circular work -Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide

72.85

-

-

... More
od28390/2020_2021 : Extra for circular work - Centering and shuttering including strutting, etc. and removal of form for: Weather shade, Chajjas, corbels etc., including edges

35.61

-

-

... More
od28391/2020_2021 : Extra for circular work -Centering and shuttering including strutting, etc. and removal of form for: Stairs, (excluding landings ) except spiral - staircases)

3.22

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

245.42

-

-

... More
Masonry Works

-

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

3.63

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

118.28

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

8.14

-

-

... More
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

61.08

-

-

... More
6.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.

4.32

-

-

... More
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site

12.15

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

73.12

-

-

... More
Joinery Works

-

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

134.8

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

134.8

-

-

... More
21.2.1 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side

2.1

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

27.86

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

20

-

-

... More
od5438/2020_2021 : Add for providing pin headed glass panes instead of ordinary float glass panes weighing 4 mm thick in doors, windows and clerestory window shutters ( Area of opening for glass panes excluding portion inside rebate shall be measured.)

0.41

-

-

... More
od107028/2020_2021 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including including applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer,conveyance of all materials, labour, etc. as directed by Engineer in Charge at all levels. Using M.S. angels 40x40x6 mm for diagonal braces

2.1

-

-

... More
od107379/2020_2021 : Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC /aluminum sliding window with necessary screws etc. complete.

16

-

-

... More
9.76 : Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

1

-

-

... More
9.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete

2

-

-

... More
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm

2

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

4

-

-

... More
9.113 : Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge.

1

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

5.8

-

-

... More
9.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.

1.68

-

-

... More
od29022/2020_2021 : Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots including applying Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

23.25

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

41.7

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

12.39

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

0.11

-

-

... More
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm

12

-

-

... More
Steel Works

-

-

-

... More
od107375/2020_2021 : Supplying and fixing rolling shutters of approved make,made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S top cover of required thickness for rolling shutters including applying Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete, including cost and conveyance of all materials, labour charges, lead, lift etc complete as directed by Engineer in Charge at all levels. 80 X 1.25 mm M.S.Laths with 1.25mm thick top cover

63

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

45

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

11.5

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

13

-

-

... More
od314134/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete,. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

10352.31

-

-

... More
od315232/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete, including cost and conveyance of all materials, labour, scaffolding, lead,lift etc. complete as directed by Engineer- in-Charge at all levels. In stringers, treads, landings etc of staircases including use of chequered plate wherever required, all complete

616.8

-

-

... More
od107179/2020_2021 : Steel work in built up tubular sections YST 310 grade as per IS: 4923 including cutting, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes including applying Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete, closing all the open ends properly with same material cost and conveyance of all materials, labour, etc., complete as directed by the Engineer-in-Charge at all levels.

1527.54

-

-

... More
10.17 : Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

10

-

-

... More
Flooring Works

-

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

74.28

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

11.14

-

-

... More
11.5 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

457.84

-

-

... More
od314122/2019_2020 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry etc. complete

143.47

-

-

... More
11.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thick

32.98

-

-

... More
od5433/2020_2021 : Providing and laying Anti-skid Ceramic floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

2.7

-

-

... More
11.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

13.86

-

-

... More
od5437/2020_2021 : Providing and fixing PVC tile edging to match the wall tiles and finishing as directed by the Engineer-in-Charge at all levels.

8.4

-

-

... More
Finishing Works

-

-

-

... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

2160.02

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

699.26

-

-

... More
13.23.1 : Extra for plastering on circular work not exceeding 6 m in radius.In one coat

435.87

-

-

... More
13.42 : Distempering with 1st quality acrylic distemper (ready mixed) of approvedmanufacturer, of required shade and colour complete, as per manufacturer'sspecification.

318.29

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

2479.14

-

-

... More
13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm)

866.84

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

88

-

-

... More
13.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)

429.66

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

1293.99

-

-

... More
Paving and Fencing Works

-

-

-

... More
16.68 : Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

240

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

8.4

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

60

-

-

... More
16.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.

60

-

-

... More
16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade

54

-

-

... More
od108295/2020_2021 : Providing and fixing S.S. 316 L grade chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of S.S. 316 L grade wire of dia 4 mm connected to S.S. 316 L grade outer fixed frames as per approved drawings and as directed by Engineer in charge. (Note: The S.S. fixed frame shall be connected to existing R.C.C trash rack using suitable fastening/anchoring devices such as dash fasteners/anchor bolts etc. complete).

24.9

-

-

... More
Water Proofing Works

-

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

4.35

-

-

... More
22.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.

361.21

-

-

... More
22.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction ofEngineer-in-Charge.

87.12

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.

59.08

-

-

... More
od107610/2020_2021 : 15 mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm including mixing water proofing material in separately).proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)

170.97

-

-

... More
13.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. ( Note : Quantity of cement used in respective item shall be measured for payment . Dosage of water proofing compound shall be 1 kg per bag of cement or as per Manufacturer's recommendation.)

1875.52

-

-

... More
Miscellaneous Works

-

-

-

... More
23.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- charges

0.65

-

-

... More
23.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-Charge

0.43

-

-

... More
23.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.

0.43

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2.

8

-

-

... More
50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall

21

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

3

-

-

... More
19.18.3 : Supplying and fixing C.I with out frame for manholes:560 mm diameter ( heavy duty) the weight of the cover to be not less than 108 kg

2

-

-

... More
od5440/2020_2021 : Providing and applying Antitermite treatment by injecting chemical emulsion Imidacloprid emulsiable concentrate .075% for pre-constructional treatment and creating a chemical barrier as per IS 6313 (Part II) 2001 for wall trenches, foundation, top surface of plinth filling, foundation of wall and floor, along the external perimeter of the building, etc. complete conforming to manufacturers specification and as directed by the Engineer-in-Charge. (Plinth area only to be measured for the payment )

21

-

-

... More
od27650/2020_2021 : Providing and fixing SS cage of size 1mx1.3mx1.5m(one side fixed to the intakewell side wall)using SS 316 grade sheet 6mm thick with all necessary frame work & 25mm perforations including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge.

3

-

-

... More
od49160/2020_2021 : Providing and laying of 20mm downgraded metal (Coarse rubble granite Stone) of approved material as filter media in face of retaining wall stem where earth fill is present as per the directions of Engineer-in-charge. Rate inclusive of all materials,transportation and labour charges etc complete.

67.16

-

-

... More
od49162/2020_2021 : Providing weep holes in Brick/Rubble masonry/Plain/Reinforced concrete abutment, wing wall/return wall with PVC pipe 75 mm outer dia 6kgf/cm2, extending through the full width of the structure with slope of 1V : 20H towards drawing face.Complete as per drawing and Technical Specifications

84

-

-

... More
od107377/2020_2021 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.: 300 mm dia RCC pipes.

10

-

-

... More
od107611/2020_2021 : Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

3

-

-

... More
od27755/2020_2021 : Supplying and fixing C.I. cover with frame for manholes :600x600 mm square C.I. cover (Light duty) the weight of the cover to be not less than 32 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-Charge

2

-

-

... More
od108872/2020_2021 : Providing and constructing soak pit 1.5 m x 1.5 m x 1.5 m size with honey comb brick work on the sides upto a height of 0.9m and brick masonry in CM 1:6 for the balance height, providing and filling brick bats graded, upto a height of 1.2 m, providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials, labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.

1

-

-

... More
SANITARY WORKS

-

-

-

... More
17.7.2 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap

1

-

-

... More
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

1

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

1

-

-

... More
18.50.1 : Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore

1

-

-

... More
18.16.2 : Providing and fixing brass stop cock of approved quality :20 mm nominal bore

1

-

-

... More
od53262/2020_2021 : Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levels

1

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

3

-

-

... More
WATER SUPPLY

-

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 32 mm nominal outer dia pipes

6

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 25 mm nominal outer dia pipes

12

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore

3

-

-

... More
18.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore

10

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

500

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

30

-

-

... More
50.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

90

-

-

... More
50.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2

3

-

-

... More
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2

60

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

4

-

-

... More
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall

3

-

-

... More
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

3

-

-

... More
50.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall

30

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

6

-

-

... More
50.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2

6

-

-

... More
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2

3

-

-

... More
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl

1

-

-

... More
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl

1

-

-

... More
od53271/2020_2021 : Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 300 mm dia RCC pipes.

10

-

-

... More
od53273/2020_2021 : Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.

1

-

-

... More
18.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore

1

-

-

... More
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

3

-

-

... More
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2

6

-

-

... More
50.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2

12

-

-

... More
od53277/2020_2021 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 60 x 60 cm and 100 cm deep including C.I. cover 500 mm with frame (medium duty) : With bricks.Class designation 75

2

-

-

... More
od53327/2020_2021 : Supplying and fixing of centrifugal pump, with CI construction, CIimpeller,mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at al levels Capacity- 80-25 lpm Head - 9 m -19.5 m

2

-

-

... More
18.12.3 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work25 mm dia nominal bore

16

-

-

... More
18.12.4 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work32 mm dia nominal bore

8

-

-

... More
HT EQUIPMENTS

-

-

-

... More
od110946/2020_2021 : 11kV HT VCB panel Supply, installation, testing commissioning of 11kV, 25 kA for 3 Sec., 630A, 3 ph, 50Hz Horizontal draw out HT indoor extendable type Vacuum circuit breaker panel with 230V AC motor operated spring charged mechanism, anti-pumping device, 24V DC shunt trip and closing coil, mechanical operation counter, 4 NO + 4 NC Aux. contact with contact multiplication contactor, automatic safety shutter, mechanical close/trip knob, mechanical on/off indication, 24V DC power pack for 3 operations for individual VCB and indicators, operating handle. The panel shall be totally enclosed, free standing, floor mounting, dust vermin proof, indoor cubical type, IP42, made of 14SWG sheet steel powder coated with necessary cable alley busbar chamber. The panel shall be with 630A aluminium PVC sleeved busbar support insulators, space heater with thermostat, cubicle illumination lamp, MCBs for AC/DC Control etc, seal off bushings, control wiring etc. The panel consists of : Incomer 11kV, 25 kA for 3 Sec, 630A VCB -1No. Resin Cast 3 phase PT, 50VA, 11KV/110V, class 0.5 resin cast potential transformer complete with HT/LT HRC fuse - 1set 3 nos of Current transformer of 200/5 A dual core (Core 1 - 15VA class 0.5 for metering and 15VA 5P10 for protection) Metering : 1 no. Ammeter with ammeter selector switch, 1 no. Voltmeter with voltmeter selector switch, Digital Power meter with RS 485 communication facility Protection : 1 set of three over current and earth fault relay and 1 no. Master trip relay. 1set Indication lamp for breaker such as ON / OFF / Auto Trip / Spring charged / Healthy trip indication and R,Y,B phase indication lamps. 1 set TNC breaker control switch and trip circuit healthy push button 630A TP Aluminium Busbar Outgoings 11kV, 25 kA for 3 Sec, 630A VCB - 2Nos. 3 nos of Current transformer of 100/5 A dual core (Core 1 - 10VA class 1 for metering and 10VA 5P10 for protection) - 2 Set Protection for each outgoing feeder : 1 set of three over current and earth fault relay and 1 no. Master trip relay - 2 Set Power pack suitable for 3 operations Indication lamp for breaker such as ON / OFF / Auto Trip / Spring charged / Healthy trip indication - 2 set 6 Window anunciation panel Metering : 1 no. Ammeter with ammeter selector switch, 1 no. Voltmeter with voltmeter selector switch, Digital Power meter with RS 485 communication facility TNC breaker control switch and trip circuit healthy push button - 3 set Cable Earthing truck - 1No. suitable for all cubicle Bus PT 3 Nos Resin Cast ,1ph PT, 50 VA, 11KV/110V, class 0.5, drawout type complete with HT/LT HRC fuse RYB indication lamp - 1set (0-12)kV Voltmeter -3 Nos. The panel shall be with bottom entry to receive incoming outgoing cable, all necessary interconnection accessories as per particular specification single line diagram.

1

-

-

... More
od110947/2020_2021 : 11kV Outdoor RMU (Extensible Type) Design, Fabrication, Supply, Installation Testing and Commissioning of 11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated,Ring Main Unit outdoor type (IP-54) with 2 nos Load break switch as incomer and 1 no motorized VCB (fully rated earth switch) with fully encapsulated vacuum interrupter panel as outgoings, 630 Amp continously rated Cu busbar complete with all accessories, protective relays, indicators,battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale,provision for padlocking for open, close, earth and test position etc. on a suitable foundation. The RMU must be both side extensible type .The rate quoted shall be inclusive of required foundation, mounting accessories, hoisting to its location,assembling of units,lining up, bolting the units and checking all control wiring complete as per single line diagram technical specification.

1

-

-

... More
od118194/2020_2021 : HT Meteing Kiosk with Meteing Supply,installation,testing and commissioning of TOD meter KIOSK with with suitably rated 11KV CT Class 0.2S, 11KV class 0.2 PT, TOD meter and test terminal block,control fuses, armoured copper cable between CT PT unit and TODmeter. The KIOSK shall be made out of 2mm thick CRCA sheet steel totally enclosed, IP 54, weather proof,undergone seven tank process,powder coated finish, complete as per the requirement of K.S.E.B. earthing, entire civil work including suitable foundation accessories as required.

1

-

-

... More
od110950/2020_2021 : 630 KVA 11/0.433kV Oil Cooled Transformer Supply, installation, testing and commissioning of 630kVA, DYn11, 3Ph, 50Hz, 11/0.433 kV,ONAN cooled, copper wound Indoor distribution transformer with tappings from +5% to -10% in steps of 2.5% with OFTC. The HT LT side shall have cable end box for XLPE cable . HT cable chamber shall be bottom entry and LT cable chamber shall be top entry type. The transformer shall have suitable enclosure with suitably rated neutral CT on earthed star point with connector for connection Earth Fault relay in HT/LT panel as per SLD. The transformer shall be complete with all standard accessories and fittings conform to IS:2026. The rate shall be inclusive of neutral CT, all protective devices as per statutory norms, pro materials, lead, lift, first fill of oil, necessary civil works for transformer foundation etc. complete as per single line diagram particular specification. Losses of the Transformer shall be as per IS:1180 Level 2. Voltage Ratio: 11/0.433 kV Type of Winding: Copper Fittings: Standard fittings as per IS:2026/77

2

-

-

... More
LT PANEL BOARD AND ACCESSORIES

-

-

-

... More
od110955/2020_2021 : MOTOR STARTER PANEL (TYPICAL) SITC of LT Switch Board, cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. There shall be compartmentalisation between breakers and functional units as well as busbars and cables. Incomer 630A, 36kA, FP, MCCB with adjustable thermal magnetic release with OL SC protection - 1 no. Instruments RYB Indicating lamps LED type, Voltmater, Voltmater Selector Switch, Ammeter Class 1 with 90 deg defl. Scale, Ammeter selector switch, ON-OFF -TRIP indication lamp, 10 VA Class 1 CTs for metering, 5P10 10VA CT for protection, Digitalmultimeter to read V,A.Hz,PF,kWH etc. as required per Single line diagram SOFT STARTER for 3 phase, 50Hz motor of 200kW capacity - 1no Motor protection relay to offer following protections: Thermal overload, Short circuit, earth fault, Negative sequence, Under voltage, number of starts and locked rotor for each motor outgoing The panel shall be Top Entry and suitable for termination of cable/Bus system as per Single line diagram and technical specification

5

-

-

... More
od110956/2020_2021 : APFC PANEL SITC of LT Switch Board, cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. There shall be compartmentalisation between breakers and functional units as well as busbars and cables. Incomer 320A, 36kA, FP, MCCB with adjustable thermal magnetic release with OL SC protection - 1 no. Instruments RYB Indicating lamps LED type, Microprocessor based intelligent, 10 step IPFC relay with PF display and necessary accessories,(0-500)V Voltmeter Class 1 with 90 deg defl. Scale, Ammeter Class 1 with 90 deg defl. Scale, Ammeter selector switch ,Auto / manual selector switch,ON-OFF -TRIP indication lamp -, Voltmeter selector switch , 10 VA Class 1 CTs for metering, Digitalmultimeter to read V,A.Hz,PF,kWH etc. as required per Single line diagram Busbar 320A TPN busbar chamber with Aluminium busbar. Outgoing 125A, 25kA, TP+NL, MCCB with adjustable thermal magnetic release with OL SC protection - 3 no. 63A, 25kA, TP+NL, MCCB with adjustable thermal magnetic release with OL SC protection - 3 nos. 32A, 25kA, TP+NL, MCCB with adjustable thermal magnetic release with OL SC protection - 3 nos. 50 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -1 No. 20 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -2Nos. 10 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -2 No. 5 kVAr capacitor duty contactor(AC6B) with illuminated ON- OFF pushbuttons (LED type) -1Nos. 50 kVAr,480-520 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 1 No 20 kVAr,480-520 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 2Nos 10 kVAr,480-520 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 2Nos 5 kVAr,480-520 V,50 Hz heavy duty capacitor(APP-H) with 7 % Seriesreactor - 1 No Control wiring required for no load compensation capacitor The panel shall be Top Entry and suitable for termination of cable/Bus system as per Single line diagram and technical specification

2

-

-

... More
od110957/2020_2021 : MSB "SITC of LT Switch Board, cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The Panel shall be of Form 4b Construction. Panel shall have suitable LT chambers for termination of Busduct / cable as mentioned in SLD" Incomer-1 and 2 1000A, Four pole, 50 KA, Electrical Draw Out type ACB with microprocessor based adjustable overcurrent and earthfault release, RS 485 communication facility - 2 No. Instruments like 2A HRC fuse with base ,RYB indication lamp LED type ,(0-500)V voltmeter Acc. class 1 with 90 deg defl. scale , ammeter Acc. class 1 with 90 deg defl. scale ,6A 3 pole voltmeter selector switch ,1000/5A 15VA class 1 resin cast CT for APFC relay for capacitor panel ,Digital power analyser/meter having RS 485 communication facilities, 1000/5A 15VA class PS resin cast CT (For REF), 1000/5A 15VA CL:0.5 CT for metering, 1000/5A 5VA CL:1 CT for APFC Relay etc. required per Single line diagram Buscoupler 1000A, Four pole, 50 KA, Electrical Draw Out type ACB with microprocessor based with RS 485 communication facility - 1 No. 1000A TPN busbar chamber with Aluminium busbar. Pluggable type surge arrester Class B+C / Class 1+2 as per IEC 61643 (IP 20)- 1 set Out goings 630 A, TP+NL, 50kA, MCCB with adjustable thermal magnetic release with OL SC protection - 9 Nos 320 A, TP+NL, 50kA, MCCB with adjustable thermal magnetic release with OL SC protection - 2 Nos 100 A, TP+NL, 50kA, MCCB with adjustable thermal magnetic release with OL SC protection - 1 Nos ON OFF TRIP indication lamp - as per SLD RYB indication lamp, LED type - as per SLD Digital Multifunction meter - as per SLD 400/5A 15VA class 1 resin cast CT - as per SLD The main panel shall have space provision to incorporate CO2 flooding system ( Fire protection) as per NBC 2016. All control wiring between Transformers and MSB shall be ocnsidered in the scope of this item. The panel shall be Top Entry and suitable for termination of cable/Bus system as per Single line diagram and technical specification.

1

-

-

... More
od110958/2020_2021 : AUXILLARY PANEL SITC of LT Switch Board, cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, free standing, floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The Panel shall be of Form 4b Construction. Incomer 100A, FP, 36kA, Moulded Case Circuit Breaker with thermal release and neutral link .- 1no Instruments RYB Indicating lamps LED type, (0-500)V Voltmeter Class 1 with 90 deg defl. Scale, Ammeter Class 1 with 90 deg defl. Scale, Voltmeter selector switch , 10 VA Class 1 CTs for metering, Digitalmultimeter to read V, A, Hz, PF, kWH etc. as required per Single line diagram 100A TPN busbar chamber with Aluminium busbar. Out goings 63A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 5nos. 32A TP+NL Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 3nos. The panel shall be Top Entry and suitable for termination of cable/Bus system as per Single line diagram and technical specification

1

-

-

... More
CABLES AND ACCESSORIES

-

-

-

... More
od110959/2020_2021 : Supply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade(earthed) conforming to IS 7098 amended upto date. 3C X 300 sq.mm.

130

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

120

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

10

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

7

-

-

... More
od110988/2020_2021 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed copper conductor cable of 1.1 kV grade as required. 2C 1.5 Sq.mm Cu

4

-

-

... More
od110989/2020_2021 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed copper conductor cable of 1.1 kV grade as required. 2C 4 Sq.mm Cu

4

-

-

... More
od110990/2020_2021 : Supplying and making end termination with brass compression gland and Copper lugs for following size of XLPE insulated PVC sheathed copper conductor cable of 1.1 kV grade as required. 4Cx2.5 sqmm Cu cable

10

-

-

... More
9.1.19 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 300 sq. mm (70mm)

20

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

8

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

12

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

2

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

4

-

-

... More
od110991/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 10 Sq.mm Al

176

-

-

... More
od110992/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 4 Sq.mm Cu

44

-

-

... More
od110993/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 2C 1.5 Sq.mm Cu

198

-

-

... More
od110994/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 2.5 sqmm Cu

110

-

-

... More
od110995/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 4C 35 Sq.mm Al

33

-

-

... More
od110998/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3C 300 Sq.mm Al

980

-

-

... More
od187301/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 185 Sq. mm Al

120

-

-

... More
od187302/2020_2021 : Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. 3.5C 400sqmm cable

42

-

-

... More
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

123

-

-

... More
7.7.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

42

-

-

... More
7.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

20

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

100

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

120

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

100

-

-

... More
7.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

80

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

400

-

-

... More
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm

10

-

-

... More
7.5.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 185 sq. mm and upto 400 sq. mm

50

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

228

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

430

-

-

... More
14.13.1 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia

50

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

50

-

-

... More
14.14.4 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.300 mm dia

24

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.

10

-

-

... More
od111016/2020_2021 : Fabrication, supply and installation of following size of Ladder type Hot dip Galvenised G.I cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required as per technical specification with suitable suspenders/supports/ bends/ supporting materials etc complete including painting as required. The rate includes required cable tray supports. 300 mm width X 50 mm depth X 2.0 mm thickness

30

-

-

... More
od111017/2020_2021 : Fabrication, supply and installation of following size of Ladder type Hot dip Galvenised G.I cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required as per technical specification with suitable suspenders/supports/ bends/ supporting materials etc complete including painting as required. The rate includes required cable tray supports. 450 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
od111018/2020_2021 : Fabrication, supply and installation of following size of Ladder type Hot dip Galvenised G.I cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required as per technical specification with suitable suspenders/supports/ bends/ supporting materials etc complete including painting as required. The rate includes required cable tray supports. 600 mm width X 50 mm depth X 2.0 mm thickness

84

-

-

... More
od122208/2020_2021 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
od122209/2020_2021 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
od111019/2020_2021 : Providing fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc.The mortar shall have minimum hardened density of 0.8 g/cm3 and It should have a compressive strength of 2.9N/Sq mm . The product shall be Smoke Air Seal and 30 years Age tested as per Dafstb and DIBT standards. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.

0.5

-

-

... More
od111021/2020_2021 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as required

448

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

45

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

2

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

265

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

238

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

165

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

50

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

50

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

20

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

1

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

1

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

2

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).

4

-

-

... More
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

9

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

10

-

-

... More
MCBs AND MCB DISTRIBUTION BOARDS

-

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

2

-

-

... More
od111256/2020_2021 : Cable end box for 12 way double door horizontal type SPN DB

2

-

-

... More
od111257/2020_2021 : Cable end box for 8 way double door horizontal type TPN DB

1

-

-

... More
od111258/2020_2021 : Cable end box for vertical TPN DB (MCB incomer)

2

-

-

... More
od111259/2020_2021 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (8 + 24), Double door

1

-

-

... More
od111255/2020_2021 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door

2

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

38

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

4

-

-

... More
od111248/2020_2021 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 2 pole 25amps. (230 Volts),30mA sensitivity.

2

-

-

... More
od111249/2020_2021 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 25amps. (415 Volts),30mA sensitivity.

1

-

-

... More
od111250/2020_2021 : Supply and fixing of following rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as required 4 pole 63 amps. (415 Volts),100mA sensitivity.

2

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

20

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

2

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth,metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

2

-

-

... More
od111263/2020_2021 : Supply installation, testing and commissioning of DOL starter in sheet steel enclosure upto 5 HP , 3PHASE motor including auxilliary contactors, capacitor , and all necessary accessories as required complete.

5

-

-

... More
od111264/2020_2021 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)

2

-

-

... More
LIGHT FIXTURES AND FANS

-

-

-

... More
od111267/2020_2021 : Supply of indoor decorative surface mounted LED Batten (with lamp) with extruded aluminium housing and Polycarbonate Diffuser along with driver and surge protection, maximum system wattage of 10Watts,luminous efficacy greater than 100lumen/watt, system output >=1000lm, power factor > 0.9, rated life of L70 @ 25,000 hours,and including all the necessary accessories as required complete.(Make:-Philips BN021 LED12S 6500 PSU or Cat No: Wipro LL20-111-XXX-65-NE or Osram Lux Smart equivalent approved makes)

1

-

-

... More
od111268/2020_2021 : Supply of industrial surface mounted LED batten (with lamp) with CRCA housing and PolyCarbonate Diffuser, along with driver and surge protection, with maximum system wattage of 40 Watts, luminous efficacy greater than 100lumen/watt, system output > = 4000lm, power factor > 0.9, rated life of L70 @ 50,000 hours, and including all necessary accessories as required complete.(Make:- Philips BN308 LED40S 6500 L120 PSU WH or Cat No: Wipro Capsule LE20-491-XXX-57-G1 or equivalent approved make)

28

-

-

... More
od111269/2020_2021 : Supply of indoor surface mounted LED Batten (with lamp) with extruded aluminium housing and polycarbonate Diffuser ,along with driver and surge protection, with a maximum system wattage of 20 Watts, luminous efficacy greater than 100 lumen/watt, system output >= 2000lm, power factor > 0.9,rated life of L70 @ 50,000 hours, and including all the necessary accessories as required complete.(Make:- Cat No: Philips BN021 LED25S 6500 PSU or Wipro LL20-221-XXX-65AL1 or equivalent approved make)

6

-

-

... More
od111270/2020_2021 : Supply of IP66 LED Street Lighting luminaire ,pressure die cast aluminium housing body with optimal heat sink, with system wattage of maximum 30W with rated life of L70 @ 50,000 hours, CRI greater than or equal to 70 with system lumens greater than 3000 and system efficiency greater than or equal to 90%.The Light fitting shall be with all required accessories suitable for mounting on the pole arm.The luminaire should have Inbuilt surge protection of4KV (L-N ,L-E N-E)and should be equipped with external surge protection device (SPD) to withstand 5KV5AMake:- Cat No: Wipro LR02-331-XXX-57-XX or equivalent approved make

4

-

-

... More
od111272/2020_2021 : Supply of 400 mm size wall fan having speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor and all accessories as required complete. (Make: Orient Snow Fall or equivalant approved make)

1

-

-

... More
od111273/2020_2021 : od293125/2019_2020 : Supply of 10w LED Bulkhead fitting with die cast aluminium housing, PC diffuser and IP66 Protection suitable for operation on 230V 50Hz AC, wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire and making good the surface as required. (Make:Philips edura or equivalent approved make)

4

-

-

... More
od111274/2020_2021 : Supply of 380 mm sweep heavy duty exhaust fan indie cast aluminium with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: ALMONARD or equivalant approved make)

2

-

-

... More
od111275/2020_2021 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Orient Smart Air Exhaust or equivalant approved make)

1

-

-

... More
od111276/2020_2021 : Installation, testing and commissioning of Wall fan, including all the supports as required and wiring using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor etc complete.

1

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

39

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

44

-

-

... More
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

2

-

-

... More
od111279/2020_2021 : Installation, testing and commissioning of High bay/Mid bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 2.5 Sq.mm PVC insulated flexible copper conductor cable as required.

4

-

-

... More
EARTHING AND SAFETY EQUIPMENTS

-

-

-

... More
od111338/2020_2021 : Earthing with C.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

9

-

-

... More
od111339/2020_2021 : Supply and fixing anodised aluminum glass framed shock treatment chart.

1

-

-

... More
od111340/2020_2021 : Supplying and laying 8 swg GI wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt spring washer spaced at 50mm)

50

-

-

... More
od111341/2020_2021 : Supplying and laying 3.15mm Cu (10 SWG) Copper wire at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt spring washer spaced at 50mm)

30

-

-

... More
od111342/2020_2021 : Supplying and laying 25mm X 3mm Cu strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of nut bolt spring washer spaced at 50mm)

40

-

-

... More
od111343/2020_2021 : Providing and fixing 8 swg GI wire GI wire on surface or in recess for connections etc. as required.

27

-

-

... More
od111344/2020_2021 : Providing and fixing 3.15mm Cu (10 SWG) Cu wire on surface or in recess for connections etc. as required.

58

-

-

... More
od111345/2020_2021 : Providing and fixing 25mm X 3mm Cu Cu strip on surface or in recess for connections etc. as required.

70

-

-

... More
od111346/2020_2021 : Providing and fixing 50mm X 6mm GI GI strip on surface or in recess for connections etc. as required.

30

-

-

... More
od111347/2020_2021 : Supply and fixing of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2.5 mm for 11kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 11kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound

6

-

-

... More
od111348/2020_2021 : Supply and fixing of of fire retardant/extinguishing electrical insulated synthetic mat of 2m x 1m x 2 mm for 3.3kV grade thick, +/- 10% confirming to BIS: DOC No. ET-02 (5440) meeting requirements of IS:15652:2006 (with upto date amendment), suitable for 3.3kV voltage and having minimum width of 1000mm +/- 20mm and including supply of required quantity of adhensive / compound .

15

-

-

... More
od111349/2020_2021 : Supply and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

1

-

-

... More
od111350/2020_2021 : Supply of Rubber hand gloves suitable for 11 kV.

1

-

-

... More
od111351/2020_2021 : Supply of First aid box

2

-

-

... More
od111352/2020_2021 : Supplying and laying 50mm X 6mm GI G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt spring washer spaced at 50mm)

40

-

-

... More
5.9 : Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

50

-

-

... More
5.15 : Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

49

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
EXTERNAL LIGHTING

-

-

-

... More
od111359/2020_2021 : Supply, installation, testing and commissioning of 6m single arm long Hot dipped GI pole painted with PU coat with built- in control box prewired, with pole suitable for mounting one number of LED luminairie with lamp , concealed wiring with 3Cx 2.5 sq.mm copper wire from the control box to light fixture, and all other accessories. complete including necessary civil foundation. Along with LED Lamp with die cast Aluminium alloy housing and polycarbonate diffuser, inbuilt driver,system wattage maximum of 45 watts, lumen outputnot less than than 4500 lumen, System efficacy not less than 110 lumen per watt ,power factor >= 0.9, IP 66 compliant including all necessary accessories as required complete. Note:Incoming and outgoing cable at termination box shall be terminated with glands properly.( Luminairie Make: Wipro Skyline LR02-501-XXX-57-G1 or or LT Adornis min -or equivalent approved make)

7

-

-

... More
od161394/2020_2021 : Supply, installation, testing and commissioning of 6m long Single arm Hot dipped GI pole painted with PU coat with pole suitable for mounting one no: of all-in-one solar LED luminairie of maximum system wattage 35W complete including necessary civil foundation. The LED Luminaire shall be with battery, inbuilt driver,system wattage maximum of 35 watts, lumen output greater than 4200 lumen, System efficacy not less than 135 lumen per watt IP 65 compliant including all necessary accessories as required complete. The solar LED luminaire shall have an autonomy of 2 days. (Luminairie Make:WIPRO LR19-561-XXX-57-XX or equivalent approved make)

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.