Kerala Electrical And Allied Engineering Company Limited Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Kerala Electrical And Allied Engineering Company Limited - KEL Tender
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date9 Apr 2025
Closing Date29 Apr 2025
Tender Amount₹ 50,56,489
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KEL_759402_1Tender No
KEL/ KEMG/14/2025-26Tender Authority
Kerala Electrical And Allied Engineering Company Limited ViewPurchaser Address
-Website
http://https://www.kel.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.br Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.
27
-
-
... More
90.14.3.2 : Supply and providing heavy duty 'A' section neoprene gasket in the panel board
27
-
-
... More
od199229/2024_2025
Supply and fixing of 2 nos. of 25A 2 Pole AC 1 rated power contactor, 25A Connector, 1 nos. of Digital
timer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor
cable, 1.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable needed.
18
-
-
... More
od199230/2024_2025
Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted
on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable
18
-
-
... More
od199231/2024_2025
Supply Conveyance and Installation of Surge protector device of IP 20 Mounting type : Screw, Voltage proctection level (UP), Nominal voltage : 230V, UOC: 10KV, L-N:7 KV , L-PE:7 KV,N-PE:7 KV, Nominal
discharge current (8/20): 10KA, Tottal discharge current (8/20): 60 KA, Response time: 35 ns, Ta: -10-
55
18
-
-
... More
90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
180
-
-
... More
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
18
-
-
... More
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Double pole
18
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
18
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
18
-
-
... More
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
216
-
-
... More
90.6.5.12
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq
mm
180
-
-
... More
5.3 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
36
-
-
... More
90.16.4.2
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using
clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps
not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3
mm GI strip
108
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
36
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
108
-
-
... More
90.12.1.12
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling
the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core
4 sq mm
144
-
-
... More
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of
HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
144
-
-
... More
od199232/2024_2025
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.br3 X 4 sq. mm (19mm)
36
-
-
... More
CIVIL WORKS
-
-
-
... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
25.2
-
-
... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
1.8
-
-
... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
65.52
-
-
... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
503.5
-
-
... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
9.39
-
-
... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
17.33
-
-
... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
15.65
-
-
... More
od199228/2024_2025
Supply and fixing of Name Board with Angles, Flats, Square pipe, ACP Sheet including Nut &brBolt
18
-
-
... More
Fabrication ,supply, conveyance and installation of Granite name board indicating the cost involved, the
commencement, completion and inauguration date etc.
1
-
-
... More
Charges for KSEB connection including all laison works (Actual Amount paid on production of
receipt).
1
-
-
... More
SUPPLY AND INSTALLATION OF 12 MTR HIGH MAST SYSTEM
-
-
-
... More
90.15.2.3 : Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters
9
-
-
... More
Installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
54
-
-
... More
od199271/2024_2025
Supply and installation of Twin unit aviation LED obstruction light with stand yellow-painted die-cast
aluminium alloy housing, red coloured polycarbonate dome and BC /EC lamp holders suitable for LED
lamp
9
-
-
... More
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.br Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.
22.5
-
-
... More
90.14.3.2
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding
suitable for 1.60/ 2.00 mm sheet
36
-
-
... More
od199272/2024_2025
Supply and fixing of 25 A 2 Pole AC 1 rated power contactor,25 A connector, Digital Timer, suitable
copper socket,2.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5
sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, OBO bettermann makes
V25-B+C/1+ NPE (switching/lighting protection) for single phase protection.
9
-
-
... More
od199273/2024_2025
Supply and fixing of 2 nos.of 25A 3 Pole AC 1 rated power contactor, Selector switch for motor
control,brsupply and fixing flush head push button NO-NC, 1.5 sq. mm ISI marked FRLS PVC
insulated single corebrcopper conductor cable and 2.5 sq. mm ISI marked FRLS PVC insulated single
core copper conductorbrcable
9
-
-
... More
od199274/2024_2025
Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32 A 2-Way neutral links
mounted on DMC/SMC base and 2.5 sq.mm ISI marked FRLS PVC insulated single core copper
conductor cable.
9
-
-
... More
90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
135
-
-
... More
1.21.5
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/
recess including cutting the wall and making good the same in case of recessed conduit as required.50
mm
54
-
-
... More
2.14.1
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.25 amps
9
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
9
-
-
... More
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Double pole
9
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
9
-
-
... More
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
135
-
-
... More
5.3
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
9
-
-
... More
90.16.4.2
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using
clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps
not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3
mm GI strip
40.5
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
54
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
36
-
-
... More
90.12.5.2
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.2 core 6 sq mm
54
-
-
... More
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of
HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
36
-
-
... More
9.1.2
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.2 X 10 sq. mm (19mm)
36
-
-
... More
CIVIL WORKS
-
-
-
... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
45
-
-
... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
9
-
-
... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
2.69
-
-
... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
76.5
-
-
... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
1035
-
-
... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
19.94
-
-
... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
20.16
-
-
... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
24.62
-
-
... More
FABRICATION,SUPPLY, CONVEYANCE AND INSTALLATION OF GRANITE BOARD INDICATING THE COST
INVOLVED,COMMENCEMENT,COMPLETION AND INAUGURATION
1
-
-
... More
ACP Sheet Name Board
1
-
-
... More
Charges for KSEB connection including all laison works (Actual Amount paid on production of
receipt).
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements