Kerala Electrical And Allied Engineering Company Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Electrical And Allied Engineering Company Limited - KEL Tender

Works
Electrical Goods and Equipments
Electrical and Electronics
Eprocure
Opening Date5 Dec 2022
Closing Date12 Dec 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.4.2 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door

1

-

-

... More
2.4.1 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/ Isolator)8 way (4 + 12), Double door

1

-

-

... More
2.3.4 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

1

-

-

... More
2.15.3 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amp

1

-

-

... More
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.15.1 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
2.14.3 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

1

-

-

... More
2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

1

-

-

... More
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

30

-

-

... More
2.10.3 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole

1

-

-

... More
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

3

-

-

... More
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

18

-

-

... More
2.13.3 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps

1

-

-

... More
2.13.2 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.12.2 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

1

-

-

... More
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
2.20 Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth,metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
2.18 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
10.5.4 Supplying and making outdoor cable end ermination with heat shrinkable jointing kit ompletewith all accessories including lugs suitable for following size of 3 core, XLPE aluminium onductorcable of 11 KV grade as required :300 sq. mm

1

-

-

... More
10.4.4 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

7

-

-

... More
9.1.31 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

12

-

-

... More
9.1.30 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

2

-

-

... More
9.1.29 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

2

-

-

... More
9.1.27 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
9.1.26 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

2

-

-

... More
9.1.25 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
9.1.24 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

2

-

-

... More
9.1.23 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

2

-

-

... More
9.1.22 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

2

-

-

... More
9.1.21 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

2

-

-

... More
9.1.34 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

2

-

-

... More
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

2

-

-

... More
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

2

-

-

... More
14.15.5 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal

1

-

-

... More
14.15.4 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal)

1

-

-

... More
14.15.3 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)

250

-

-

... More
14.15.2 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)

1

-

-

... More
14.15.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)

1

-

-

... More
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C

20

-

-

... More
1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

1

-

-

... More
1.55.3 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable insurface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single corecable etc. as required Group C.

10

-

-

... More
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

5

-

-

... More
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).

8

-

-

... More
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

5

-

-

... More
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

1

-

-

... More
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

2

-

-

... More
1.27.3 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

1

-

-

... More
1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

1

-

-

... More
1.27.5 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

1

-

-

... More
1.27.6 Supplying and fixing following size/ modules, GI Box along with modular base & cover plate for modular switches in recess as required. 12 module ( 200mm x 150mm)

1

-

-

... More
1.24.6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

1

-

-

... More
1.24.7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet

1

-

-

... More
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.

15

-

-

... More
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

15

-

-

... More
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire

200

-

-

... More
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

200

-

-

... More
1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire

300

-

-

... More
1.14.4 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

10

-

-

... More
1.14.5 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire

15

-

-

... More
1.14.6 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire

5

-

-

... More
1.18.2 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the xisting surface/ recessed steel/ PVC conduit as required.2 Pair

30

-

-

... More
1.18.3 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 Pair

1

-

-

... More
1.19 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid nd protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.

10

-

-

... More
1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

30

-

-

... More
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

60

-

-

... More
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

60

-

-

... More
1.41 Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

5

-

-

... More
1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.

20

-

-

... More
1.50.1 Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep

10

-

-

... More
1.47 Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

5

-

-

... More
2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

-

-

... More
2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

3

-

-

... More
HT ENERGY METERbrSupply, installation, Testing and commissioning of CT, PT connected TOD Meter of approved brand and conforming to relevant IS and KSEB, Electrical Inspectorate regulations, IP 51 with unbreakable transparent cover, provision for sealing, anti-tamper features, real time and calibrated quartz clock tested by KSEB. This scope also includes the testing of TOD Meter and obtaining test certificate from Electrical Inspectorate / KSEB / TMR. (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents).

1

-

-

... More
EMERGENCY PUSH BUTTON Supply, installation, testing and commission of Emergency Stop Push Button with enclosure for the Transformer.

1

-

-

... More
MAIN SWITCH BOARD WITH AMF Supply, installation, testing & commissioning of inspecterate approved cubical type Main Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalised design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 1250 Amps capacity extensible type TPN Aluminum alloy bus bars of high conductivity,DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 32 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen) copper conductor cables, cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate and the consultant Busbar 2 Run of 75 x 10mm AL.Busbar for each Phase 1 Run of 75 x 10mm AL.Busbar for Neutral EB Incomerbr1 Nos - 1250A, 50kA 4P Microprocessor based EDO ACB with O/C, E/F releases, having thermal memory, breaker contact wear and tear indication in percentage, provision to connect to computer through RS485 port in future and LSIG, Phase unbalance, Over temperature and Nuetral Protections.br1 Set - RYB Indication lamps with Control MCBsbr3 Nos -630/5A CL:1, 10VA CTbr1 Nos - Digital Multifunction Meter measuring V, A ,F, KWH, KVA, PF with Control MCBsbr1 Nos - Stand by Earth Fault RelaybrDG Incomer - Ibr1 Nos - 1250 A 36kA 4P Microprocessor based EDO ACB with E/F releases, ROM and spreaderbr1 Set - RYB Indication lamps with Control MCBsbr3 Nos - 400/5A CL:1, 10VA CTbr1 Nos - Digital Multifunction Meter measuring V, A , F, KWH, KVA, PF with Control MCBsbr1 Nos - 630A 4P Power Contactor (AC3)br1 Nos - Stand by Earth Fault RelaybrSurge Protection Devicebr3 Nos - 4 Module DIN Rail Mounting Type 1 + Type 2 / Class 1 + class II 100kA SPD on the incoming side of EB Incomer Supply, DG Incomer 1 Supply and DG Incomer 2 Supply with all accessories etc.complete as required. The connections to RYB Phases, Neutral and Earth shall be done using 16 Sq.mm Single Core Flexible Copper conductor cables with less than 0.45 m in length. brOutgoings (On EB Incomer & DG - I Incomer)br2 Nos - 630A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader.br2 Nos - 250A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader.br1 Nos - 125A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader.br1 Nos - 125A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision and metering provision with E/F releases, ROM and spreader.

1

-

-

... More
APFC PANEL 1&2 (120 KVAR) Supply, installation, testing & commissioning of Inspecterate approved cubical type Automatic Power Factor Correction Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 250 Ampsbrcapacity type TPN Aluminum alloy bus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen ) copper conductor cables, cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate and the consultant. Busbarbr1 Runs of 32 x 10mm AL.Busbar for each Phasebr1 Runs of 32 x 6 mm AL.Busbar for NeutralbrIncomerbr1 Nos - 250A 4P Isolatorbr1 Set - RYB Indication lamps with Control MCBsbr3 Nos - 250/5A CL:1, 10VA CTbr1 Nos - Digital Multifunction Meter measuring V,A,F,KW, KVA,PF with Control MCBs br1 Nos - 8 Stage Microprocessor based APFC Relaybr1 Nos - 630/5A CL:1, 10VA CT in MSBbrOutgoingsbr1 Nos - 63A TP MCB with Capacitor Duty Contactor and 25 KVAr Heavy Duty Cylindrical Type Capacitor.br2 Nos - 40A TP MCB with Capacitor Duty Contactor and 20 KVAr Heavy Duty Cylindrical Type Capacitorbr2 Nos - 32A TP MCB with Capacitor Duty Contactor and 15 KVAr Heavy Duty Cylindrical Type Capacitorbr2 Nos - 16A TP MCB with Capacitor Duty Contactor and 10 KVAr Heavy Duty Cylindrical TYPE Capacitor br1Nos - 16A TP MCB with 5 KVAr Heavy Duty Cylindrical Type Capacitorbr8 Nos - Green ON Push Buttons with Indicatorbr8 Nos - Red OFF Push Buttons with Indicatorbr2 Nos - Cooling Fan ( 6 Inches)

2

-

-

... More
SWITCH BOARD - 1 (Lighting Panel) Supply, installation, testing & commissioning of Inspecterate approved cubical type Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 200 Amps capacity type TPN Aluminum alloy bus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (LowbrSmoke Zero Halogen) copper conductor cables cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate and the consultant.brMeteringbr4 Nos - Busbar Provision for fixing CTsbr1 Nos - Provision for fixing Three Phase Energy MeterbrFuse & Neutral Linkbr3 Nos - 200A Open Type Fuse with HRC Fuse of Suitable Ratingbr1 Nos - 200A Neutral LinkbrBusbarbr1 Runs of 32 x 10mm AL.Busbar for each Phasebr1 Runs of 32 x 6mm AL.Busbar for NeutralbrIncomerbr1 Nos - 125A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM, spreaderbr1 Set - RYB Indication lamps with Control MCBsbr3 Nos - 200/5A CL:1, 10VA CTbr1 Nos - Digital Multifunction Meter measuring V, A , F, KWH, KVA, PF with Control MCBsbr1 Nos - Earth Leakage Relay with CBCTbrOutgoingsbr4 Nos - 63A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreaderbr

1

-

-

... More
ENERGY METER & CT Supply and installation of the following Energy Meter and CTs after getting it tested from Electrical Inspectorate / KSEB / TMR. (All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents.). Three Phase 4 Wire CL : 0.5 S (CT Operated)

1

-

-

... More
ENERGY METER & CT Supply and installation of the following Energy Meter and CTs after getting it tested from Electrical Inspectorate / KSEB / TMR. (All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents.) 100/5A CL : 0.5S, 5VA Resin Cast CT

1

-

-

... More
ENERGY METER & CT Supply and installation of the following Energy Meter and CTs after getting it tested from Electrical Inspectorate / KSEB / TMR. (All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of upporting documents.). 150/5A CL : 0.5S, 5VA Resin Cast CT

1

-

-

... More
ENERGY METER & CT Supply and installation of the following Energy Meter and CTs after getting it tested from Electrical Inspectorate / KSEB / TMR. (All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents.). 200/5A CL : 0.5S, 5VA Resin Cast CT

1

-

-

... More
SWITCH BOARD - 2 (Utility Panel) Supply, installation, testing & commissioning of inspecterate approved cubical type Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 500 Amps capacity type TPN Aluminum alloy bus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen) copper conductor cables cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate and the consultant.brBusbarbr1 Runs of 80 x 10mm AL.Busbar for each Phasebr1 Runs of 80x 6mm AL.Busbar for NeutralbrIncomerbr1 Nos - 630A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM, spreader and shunt releasebr1 Set - RYB Indication lamps with Control MCBsbr3 Nos - 500/5A CL:1, 10VA CTbr1 Nos - Digital Multifunction Meter measuring V, A , F, KWH, KVA, PF with Control MCBsbr1 Nos - Earth Leakage Relay with CBCTbrOutgoingsbr2 Nos - 400A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreaderbr2 Nos - 250A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader.

1

-

-

... More
SWITCH BOARD - 3 (AC Panel)brSupply, installation, testing & commissioning of inspecterate approved cubical type Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 1.6 mm thick for frame work and covers, 3 mm thick for gland, plates cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 400 Amps capacity type TPN Aluminum alloy bus bars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 1.5 sq. mm. PVC insulated LSZH (Low Smoke Zero Halogen) copper conductor cables cable alleys etc. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate and the onsultant.brBusbarbr1 Runs of 25x 6mm AL.Busbar for each Phasebr1 Runs of 25x 6mm AL.Busbar for NeutralbrIncomerbr1 Nos - 125A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM, spreader and shunt releasebr1 Set - RYB Indication lamps with Control MCBsbr3 Nos - 125/5A CL:1, 10VA CTbr1 Nos - Digital Multifunction Meter measuring V, A , F, KWH, KVA, PF with Control MCBsbr1 Nos - Earth Leakage Relay with CBCTbrOutgoingsbr5 Nos - 63A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% setting provision with E/F releases, ROM and spreader

1

-

-

... More
2.9.7 Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dustprotected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto theterminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator).(Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way Double door

1

-

-

... More
2.9.6 Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dustprotected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto theterminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator).(Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)6 way Double door

1

-

-

... More
Supply and fixing of following ways surface / recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder coated, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (But without MCBs and incomer) as required. 6 Way (8 + 18), Double door

1

-

-

... More
MCCB Supply and fixing following rating and breaking capacity and pole MCCB with thermal magnetic release having 70 to 100% setting provision and terminal spreaders in the distribution board including making connections, etc. complete as required.br80A to 100A 25kA 4P MCCB

1

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 100 milli amps

1

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.br40 amps 100 milli amps

1

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A to 63 A Triple Pole

4

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.br25 amps

1

-

-

... More
METAL ENCLOSURE Supply and fixing Sheet Steel enclosure on surface / recess having provision to fix MCB / Isolator complete with connections, testing and commmissioning etc. as required. 4 Way

1

-

-

... More
METAL ENCLOSURE Supply and fixing Sheet Steel enclosure on surface / recess having provision to fix MCB / Isolator complete with connections, testing and commmissioning etc. as required. 2 Way

1

-

-

... More
Star-Delta STARTER Supplying, installation, testing & commissioning of Star-Delta Starter Switch Panel enclosure suitable for 5HP to 10HP compressor complete with all accessories including 4P Power Contactors, Overload Relay, ON-OFF Push Buttons, etc. complete with wiring in duly powder coated sheet steel enclosure.

1

-

-

... More
DOL STARTER Supplying, installation, testing & commissioning of DOL Starter Switch Panel enclosure suitable for 5HP to 10HP compressor complete with all accessories including 4P Power Contactor, Overload Relay, ON-OFF Push Buttons, etc. complete with wiring in duly powder coated sheet steel enclosure.

1

-

-

... More
HT CABLEbrSupply, laying, testing and commissioning of 11 KV grade XLPE insulated armoured cables of the following size and laying in earth excavated trenches, clamping in built up trenches, traysusing heavy duty Aluminium or GI Flat or by using heavy duty GI spacer saddles and on 11 KV pole structure using necessary heavy duty GI supports and clamps of which spacing of clamps not exceeding 50 cm and pulling through pipes etc including all minor civil works.br3C x 300 Sq.mm

60

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 25 Sq.mm Al. cable

10

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 35 Sq.mm Al. cable

120

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 50 Sq.mm Al. cable

50

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 70 Sq.mm Al. cable

20

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 95 Sq.mm Al. cable

25

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 120 Sq.mm Al. cable

100

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 150 Sq.mm Al. cable

100

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 185 Sq.mm Al. cable

30

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 240 Sq.mm Al. cable

20

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 300 Sq.mm Al. cable

80

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br3.5C x 400 Sq.mm Al. cable

60

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br2C x 1.5 sq.mm Copper Armoured Cable

100

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br4C x 1.5 sq.mm Copper Armoured Cable

35

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br2C x 2.5 sq.mm Copper Armoured Cable

17

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br4C x 2.5 sq.mm Copper Armoured Cable

20

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br4C x 6 sq.mm AI Cable

50

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br4C x 10 sq.mm AI Cable

50

-

-

... More
LT CABLESbrSupply, laying, testing and commissioning of PVC 1.1 KV grade XLPE insulated armoured Aluminium / Copper cables of the following sizes and laying in earth excavated trenches, clamping in built up trenches, trays, racks, risers, trusses,walls etc using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 50cm and pulling through pipes including all minor civil works.br4C x 16 sq.mm AI Cable

50

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.br2C x 1.5sq.mm. Copper Armoured cable

6

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.br4C x 1.5sq.mm. Copper Armoured cable

6

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.br2C x 2.5sq.mm. Copper Armoured cable

6

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.br4C x 2.5sq.mm. Copper Armoured cable

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.br4C x 6 Sq.mm AI Cable

2

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5C x 300 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5C x 400 Sq.mm Al. cable

12

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5C x 240 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5C x 185 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5C x 120 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5C x 150 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5C x 70 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5 C x 95 Sq. mm AI. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br2C x 2.5sq.mm. Copper Armoured cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br4C x 2.5sq.mm. Copper Armoured cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br4C x 6 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br4C x 10 Sq.mm AI. Cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br4C x 16 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br4C x 25 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5C x 35 Sq.mm Al. cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br3.5C x 50 Sq. mm AI. Cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br2C x 1.5sq.mm. Copper Armoured cable

1

-

-

... More
GLAND EARTHINGbrSupply and providing gland earthing using Aluminium or copper strip / shim / wire using copper sockets etc. complete as required conforming to Electrical Inspectorate Standards.br4C x 1.5sq.mm. Copper Armoured cable

1

-

-

... More
PLATE EARTHINGbrSupply and providing earthing with CI earth plate 600mm x 600mm x 6mm thick electrode including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required conforming to relevant IS, Electrical Inspectorate standards etc

7

-

-

... More
EARTHING CONDUCTORSbrSupply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and onnections should only be done using SS Nut and Bolts with double washers etc as required.br8 SWG Copper Wire

300

-

-

... More
EARTHING CONDUCTORSbrSupply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required.br10 SWG Copper Wire

20

-

-

... More
EARTHING CONDUCTORSbrSupply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required.br25 x 3 mm Copper Strip

30

-

-

... More
EARTHING CONDUCTORSbrSupply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SSNut and Bolts with double washers etc as required.br25 x 6 mm Copper Strip

200

-

-

... More
EARTHING CONDUCTORSbrSupply and providing the earth conductors of the following sizes and laying in earth excavated trenches, clamping in built up trenches , walls, trays, racks, risers, trusses, etc. using heavy duty Aluminium Flat or heavy duty GI spacer saddles of which spacing of clamps not exceeding 60cm without making holes in the earthing conductor and pulling through pipes including all minor civil works. All the joints should be properly tinned and connections should only be done using SS Nut and Bolts with double washers etc as required.br25 x 6 mm GI Strip

100

-

-

... More
MS STRUCTURALSbrSupply, fabrication and installation of checkered plates of 6mm thickness to use above the cable trenches duly supported with channels and duly painted with one coat of epoxy primer and two coats of epoxy grey paint.

50

-

-

... More
MS STRUCTURALSbrSupply, fabrication and installation of Transformer, Panel Board mounting supports using C Channels of adequate size painted with one coat of epoxy primer and two coats of epoxy grey paint.

50

-

-

... More
MS STRUCTURALSbrSupply, fabrication and installation of cable tray and supports using M.S angles and plates of adequate size painted with one coat of epoxy primer and two coats of epoxy grey paint.

3000

-

-

... More
CABLE ROUTE MARKERbrSupply and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted / welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long with painting and fixing the same in ground at 5 meter interval with cement concrete in M.15 Grade (1:2:4) etc. complete as required.

15

-

-

... More
PIPES FOR CABLE PROTECTION Supply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required.br25 mm dia

1

-

-

... More
PIPES FOR CABLE PROTECTION Supply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required.br50mm dia

1

-

-

... More
PIPES FOR CABLE PROTECTION Supply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required.br80mm dia

1

-

-

... More
PIPES FOR CABLE PROTECTION Supply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required.br100mm dia

1

-

-

... More
PIPES FOR CABLE PROTECTION Supply and laying of the following size medium class GI pipe in ground or clamping in wall/ceiling with heavy duty GI or Aluminium clamps etc complete as required.br150mm dia

1

-

-

... More
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 3 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

5

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.brData socket outlet

5

-

-

... More
STREET LIGHTING POLE Supply, installation, testing & commissioning of 7 meter high hot dip galvanised Octagonal poles with double arm bracket, 130mm bottom dia and 70mm top dia made up of 3mm thick sheet along with base plate of size 200 x 200 x 12mm.

1

-

-

... More
STREET LIGHTING POLEbrSupply, installation, testing & commissioning of 8 meter high hot dip galvanised Octagonal poles with double arm bracket, 130mm bottom dia and 70mm top dia made up of 3mm thick sheet along with base plate of size 200 x 200 x 16mm

1

-

-

... More
STREET LIGHTING POLEbrSupply, installation, testing & commissioning of 9 meter high hot dip galvanised Octagonal poles with double arm bracket, 155mm bottom dia and 70mm top dia made up of 3mm thick sheet along with base plate of size 250 x 250 x 16mm

1

-

-

... More
STREET LIGHTING LEDbrSupply, installation, testing & commissioning of the following Watts Graphite grey powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminiumbrframe with heat resistant toughened clear glass fixed with SS screws. LEDs shall provided with secondary lens optics to get optimum optical performance. he drivers used shall be specially designed to have built-in surge voltage, open / short circuit protections.Internal surge of 5 KV and External surge protection of 10 KV provided for additional safety. Luminaire shall have CCT of 5700, CRI 70, IP 66 protection, IK 07, PF.95, THD 10%,operating voltage range of 150 - 300v AC, and 120 Lumesn/watt efficiency with a lumen package of 12000br70 W

10

-

-

... More
STREET LIGHTING LEDbrSupply, installation, testing & commissioning of the following Watts Graphite grey powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminiumbrframe with heat resistant toughened clear glass fixed with SS screws. LEDs shall provided with secondary lens optics to get optimum optical performance. he drivers used shall be specially designed to have built-in surge voltage, open / short circuit protections.Internal surge of 5 KV and External surge protection of 10 KV provided for additional safety. Luminaire shall have CCT of 5700, CRI 70, IP 66 protection, IK 07, PF.95, THD 10%,operating voltage range of 150 - 300v AC, and 120 Lumesn/watt efficiency with a lumen package of 12000br100 W

10

-

-

... More
STREET LIGHTING LEDbrSupply, installation, testing & commissioning of the following Watts Graphite grey powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminiumbrframe with heat resistant toughened clear glass fixed with SS screws. LEDs shall provided with secondary lens optics to get optimum optical performance. he drivers used shall be specially designed to have built-in surge voltage, open / short circuit protections.Internal surge of 5 KV and External surge protection of 10 KV provided for additional safety. Luminaire shall have CCT of 5700, CRI 70, IP 66 protection, IK 07, PF.95, THD 10%,operating voltage range of 150 - 300v AC, and 120 Lumesn/watt efficiency with a lumen package of 12000br120 W

10

-

-

... More
STREET LIGHTING FoundationbrProviding required RCC foundation for Street Light Pole after excavating of the soil to the required depth. The concrete mix for PCC shall be in M:15 Grade (1:2:4) and that of RCC shall be in M:20 Grade (1:1.5:3). The contractor shall submit the drawings of the foundation to the Engineer/ Manager in charge and Consultant for getting approval before the commencement of work or the work shall be executed as per the drawings given to the contractor.

1

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebr2 x 2 (2 Feet x 2 Feet) LED Light

10

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebrIndustrial type LED Tube Set of 2 x 20W with Tube

10

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebrIndustrial type LED Tube Set of 1 x 20W with Tube

10

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebrLED Bulb (up to 12W)

2

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at site brBattern/Angle Holder

3

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebrHigh Speed Metal Type Exhaust Fan of Sweep 200 mm

1

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebrHigh Speed Metal Type Exhaust Fan of Sweep 225mm

1

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebr60W Ceiling Fan of Sweep 1200mm

10

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebr50W LED Flood Light

10

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebr100W LED Flood Light

10

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebr120W LED Highbay Light

20

-

-

... More
SUPPLY OF LIGHT & OTHER FITTINGSbrSupply and providing the following fittings and items at sitebrHigh Speed Metal Type Exhaust Fan of Sweep 150 mm

1

-

-

... More
INSTALLATION OF LIGHT & OTHER FITTINGS Installation, testing and commissioning of 50W LED Flood light fittings complete with all accessories directly on wall/ piller/ceiling, including giving br connections etc. as required

5

-

-

... More
INSTALLATION OF LIGHT & OTHER FITTINGS Installation, testing and commissioning of 100W LED Flood light fittings complete with all accessories directly on piller/ceiling, including giving connections etc. as required

10

-

-

... More
INSTALLATION OF LIGHT & OTHER FITTINGS Installation, testing and commissioning of 120W LEDbrHighbay light fittings complete with all accessories directlybron ceiling, including giving connections etc. as required.

1

-

-

... More
INSTALLATION OF LIGHT & OTHER FITTINGS Installation, testing and commissioning of 2 x 2 (2 Feet x 2 Feet) LED Ceiling light fittings complete with all accessories directly on the ceiling by cutting the ceiling including giving connections etc. as required.

10

-

-

... More
INSTALLATION OF LIGHT & OTHER FITTINGS Installation, testing and commissioning of PVC battern / angle holder fitting complete with all accessories directly on ceiling/wall, including giving connections etc. as required.

15

-

-

... More
POINT WIRING Supply and fixing suitable size GI box / PVC surface box with modular plate and socket outlet and 15/16 A modular switch, connections etc. as required cover in front on surface or in recess, including providing and fixing 6 pin br 5/6 & 15/16 A modular

3

-

-

... More
CIVILbrSupply of all materials and providing electrical room of 30 x 20 ft for USS and Panels including roofing , transformer foundation and alteration of existing Building

1

-

-

... More
FAN ROD Supply and fixing extra down rod of 20cm legnth G.I pipe 15mm dia, heavy guage including painting etc. as required. (Note: More than 5cm length shall be rounded to the nearest 10cm and 5cm or less shall be ignored).

5

-

-

... More
SAFETY EQUIPMENTS Supply and fixing laminated shock treatment chart duly mounted on a good frame work

1

-

-

... More
SAFETY EQUIPMENTS Supply and providing First Aid Box as approved by St.John Ambulance Brigade / Indian Red Cross conforming to IS 2217 : 1963

1

-

-

... More
SAFETY EQUIPMENTS Supply and providing a set of 2 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint "FIRE" and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.

3

-

-

... More
SAFETY EQUIPMENTS Supply and fixing safety instruction chart in word duly framed in good frame work as required.

1

-

-

... More
SAFETY EQUIPMENTS Supply and fixing 2Kg Dry Chemical Powder (DCP) type fire extinguisher complete with Gun Metal cap, hose with squeeze grip nozzle, wall fixing brackets conforming to BIS: 2171 and with ISI mark

3

-

-

... More
SAFETY EQUIPMENTS Supply and providing tested industrial safety helmet conforming to IS 2925 : 1984

2

-

-

... More
SAFETY EQUIPMENTS Supply and providing 11KV tested discharge rod conforming to IEC 61230

1

-

-

... More
SAFETY EQUIPMENTS Supply and providing 1 pair of 11KV tested rubber gloves conforming to IS 4770 : 1991.

1

-

-

... More
SAFETY EQUIPMENTS Supply and providing electrical grade rubber mat of size 2m x 1m having 6mm thickness in front of panels and DBs conforming to IS 15652 : 2006 standard.

2

-

-

... More
SAFETY EQUIPMENTS Supply and providing electrical grade rubber mat of size 2m x 1m having 12mm thickness in front of panels and DBs conforming to IS 15652 : 2006 standard.

2

-

-

... More
DOCUMENTATIONbrCo-ordination with KSEB for getting power allocation by submission of 7 sets of HT agreement and executing the agreement etc.(All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents).

1

-

-

... More
DOCUMENTATIONbrSubmission of completion report, arranging inspection and obtaining Sanction Order from Electrical Inspectorate .(All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents).

1

-

-

... More
DOCUMENTATIONbrPreparation of drawings and getting approval from Electrical Inspectorate. (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents).

1

-

-

... More
DOCUMENTATIONbrTaking soil resistivity at site and obtaining test certificate from Electrical Inspectorate (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents).

1

-

-

... More
NOTE 1 : Sl No, 79 are not included in the scope of work and hence not shown in this BOQ. NOTE 2 : As per standing GO, Defect liability period is 36 months from the date of completion or asset handover to customer and shall be applicable to this work. Any repair and maintenance shall be provided by the contractor at own cost during warranty period

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.