Kerala Electrical And Allied Engineering Company Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KEL_732731_1Tender No
KRO/BDC/1833/2025Tender Authority
Kerala Electrical And Allied Engineering Company Limited ViewPurchaser Address
-Website
http://https://www.kel.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
2.8.1
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means
in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift up to 1.5 m, including
getting out the excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.All kinds of soil
2.4
-
-
... More
4.1.8
Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4
coarse sand : 8 graded stone aggregate 40 nominal size)
21.5
-
-
... More
4.1.3
Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse
sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
1.73
-
-
... More
5.1.2
Providing and laying in position specified grade of reinforced cement concrete,
excluding the cost of centering, shuttering, finishing and reinforcement - All work up
to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm
nominal size
24.64
-
-
... More
5.2.2
Reinforced cement concrete work in walls (any thickness), including attached
pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,
abutments, posts and struts etc. up tot floor five level excluding cost of centering,
shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded
stone aggregate 20 mm nominal size)
6.26
-
-
... More
5.3
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up
to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window
sills, staircases and spiral stair cases up to floor five level excluding the cost of
centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse
sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
40.74
-
-
... More
4.3.1
Centering and shuttering including strutting, propping etc. and removal of form work
for:Foundations, footings, bases for columns
77.16
-
-
... More
5.9.3
Centering and shuttering including strutting, etc. and removal of form for:Suspended
floors, roofs, landings, balconies and access platform
126.74
-
-
... More
5.9.5
Centering and shuttering including strutting, etc. and removal of form for:Lintels,
beams, plinth beams, girders bressumers and cantilevers
189.8
-
-
... More
5.9.6
Centering and shuttering including strutting, etc. and removal of form for:Columns,
Pillars, Piers, Abutments, Posts and Struts
104.88
-
-
... More
5.9.7
Centering and shuttering including strutting, etc. and removal of form for:Stairs,
(excluding landings ) except spiral - staircases)
14.25
-
-
... More
5.9.19
Centering and shuttering including strutting, etc. and removal of form for:Weather
shade, Chajjas, corbels etc., including edges
36.06
-
-
... More
5.9.16.1
Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and wallsUnder 20 cm wide
55.7
-
-
... More
5.22.6
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing
in position and binding all complete upto plinth levelThermo - Mechanically Treated
bars of grade Fe-500D or more
8452.23
-
-
... More
60.7.1
DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry
with good quality blasted rubble including packing to compactness to lines and levels
cost and conveyance of all materials labour charges etc. complete as per direction of
Departmental officers at site
10.5
-
-
... More
OD58876/2024-2025
Random rubble masonry with hard stone in foundation and plinth including levelling
up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate
20 mm nominal size) up to plinth level with Cement mortar 1:6 (1 cement : 6 coarse
sand)
Without marked bond stone
3.5
-
-
... More
2.25
Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited
layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
41.33
-
-
... More
50.6.2.1
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm
or nearest available size confirming to IS 2185 part I of 1979 for foundation and
plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
2.38
-
-
... More
50.6.1.2
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm
or nearest available size confirming to IS 2185 part I of 1979 for super structure up to
floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc
complete.
38.8
-
-
... More
50.6.3.2
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm
or nearest available size confirming to IS 2185 part I of 1979 for super structure up to
floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including
cost of scaffolding complete
2.48
-
-
... More
22.5
Providing and laying water proofing treatment in sunken portion of WCs, bathroom
etc., by applying cement slurry mixed with water proofing cement compound
consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with
water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air
cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with
water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air
cure for 4 hours followed with water curing for 48 hours. The rate includes
preparation of surface, treatment and sealing of all joints, corners, junctions of pipes
and masonry with polymer mixed slurry.
6.72
-
-
... More
13.1.1
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
609.62
-
-
... More
13.16.1
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
220.05
-
-
... More
5.30
Add for plaster drip course / groove in plastered surface or moulding to R.C.C.
projections.
523.95
-
-
... More
13.43.1
Applying one coat of water thinnable cement primer of approved brand and
manufacture on wall surface:Water thinnable cement primer
505.35
-
-
... More
13.60.1
Wall painting with acrylic emulsion paint of approved brand and manufacture to give
an even shade:Two or more coats on new work
505.35
-
-
... More
13.46.1
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two
or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior
primer applied @ 2.20 kg/10 sqm)
331.91
-
-
... More
11.41.2
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by
the manufacturer) with water absorption less than 0.08% and conforming to IS :
15622, of approved make, in all colours and shades, laid on 20 mm thick cement
mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement
and matching pigments etc., complete.Size of Tile 600 x 600 mm.
129.35
-
-
... More
11.47.2
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the
manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps,
laid with cement based high polymer modified quick set tile adhesive (water based)
conforming to IS : 15477, in average 6 mm thickness, including grouting of joints
(Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
40.43
-
-
... More
16.89
Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with
water absorption less than 0.5% and conforming to IS: 15622 of approved make in all
colours and shades in for outdoor floors such as footpath, court yard, multi models
location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse
sand) in all shapes & patterns including grouting the joints with white cement mixed
with matching pigments etc. complete as per direction of Engineer-in-Charge.
9.72
-
-
... More
8.2.2.2
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and
prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias
and similar locations, of required size, approved shade, colour and texture laid over
20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with
white cement, mixed with matching pigment, epoxy touch ups, including rubbing,
curing, moulding and polishing to edges to give high gloss finish etc. complete at all
levels.Area of slab over 0.50 sqm
4.17
-
-
... More
10.14.1.1
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured
from commercial mild steel sheet 1.60 mm thickness, including hinges, jamb, lock
jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm,
or base ties of 1.60 mm pressed, mild steel welded or rigidly fixed together by
mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar
guards, lock strike-plate and shock absorbers as specified and applying a coat of
approved steel primer after pre-treatment of the surface as directed by Engineer-incharge:
Profile BFixing with adjustable lugs with split end tail to each jamb
90.3
-
-
... More
10.5.2
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle
iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings
complete, including applying a priming coat of approved steel primer.Using flats
30x6 mm for diagonal braces and central cross piece
7.79
-
-
... More
21.1.1.2
Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at junctions,
i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for
glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural
drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash
fasteners to be paid for separately):
For fixed portionPowder coated aluminium (minimum thickness of powder coating
50 micron)
95.2
-
-
... More
21.1.2.2
For shutters of doors, windows & ventilators including providing and fixing hinges /
pivots and making provision for fixing of fittings wherever required including the
cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for
separately)Powder coated aluminium (minimum thickness of powder coating 50
micron)
92.99
-
-
... More
21.2.2
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer
or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling
fixed in aluminum doors, windows shutters and partition frames with C.P. brass /
stainless steel screws etc. complete as per architectural drawings and directions of
Engineer - in- Charge.Pre- laminated particle board with decorative lamination on
both sides
4.79
-
-
... More
21.3.2
Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of Engineer - in -Charge. ( Cost of
aluminium snap beading shall be paid in basic item):With float glass panes of 5.50
mm thickness
1.26
-
-
... More
21.3.1
Providing and fixing glazing in aluminium door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the
architectural drawings and the directions of Engineer - in -Charge. ( Cost of
aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm
thickness
21.02
-
-
... More
9.100.2
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or
shade, with necessary screws etc. complete:100 mm
30
-
-
... More
21.13
Providing and fixing 100 mm brass locks ( best make of approved quality ) for
aluminium doors including necessary cutting and making good etc. complete
3
-
-
... More
10.25.1
Item Shifted to Sub head 14 as item 14.73
Item Shifted to head 14 as item 14.74
Steel work welded in built up sections/framed work, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer using
structural steel etc. as required.In stringers, treads,landings etc. of stair cases,
including use of chequered plate wherever required, all complete
175.68
-
-
... More
10.6.2
Supplying and fixing rolling shutters of approved make, made of required size M.S.
laths, interlocked together through their entire length and jointed together at the end
by end locks, mounted on specially designed pipe shaft with brackets, side guides and
arrangements for inside and outside locking with push and pull operation complete,
including the cost of providing and fixing necessary 27.5 cm long wire springs
manufactured from high tensile steel wire of adequate strength conforming to IS:
4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20
mm M.S. laths with 1.20 mm thick top cover
7.2
-
-
... More
10.26.3
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing,
balcony railing, staircase railing and similar works, including applying priming coat
of approves steel primer.G.I. pipes
84.64
-
-
... More
13.61.1
Painting with synthetic enamel paint of approved brand and manufacture to give an
even shade:Two or more coats on new work
72.54
-
-
... More
50.10.2
Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing
in position and applying a priming coat of approved steel primer, including welding
and bolted with special shaped washers etc. complete
195.04
-
-
... More
OD58882/2024-2025
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coated
thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,
5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18
microns. Sheet should have protective guard film of 25 microns minimum to avoid
scratches during transportation and should be supplied in single length upto 12 metre
or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self
tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in
horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and
trusses and including cutting to size and shape wherever required.
27.14
-
-
... More
16.68
Providing and laying 60 mm thick factory made cement concrete interlocking paver
block of M - 30 grade made by block making machine with strong vibratory
compaction, of approved size, design & shape, laid in required colour and pattern
over and including 50 mm thick compacted bed of coarse sand, filling the joints with
fine sand etc. all complete as per the direction of Engineer-in-charge
90
-
-
... More
OD50871/2024-2025
Providing and fixing Granite of any colour and shade for Name board, of required
size laid over base of cement mortar 1:4 ( 1 cement : 4 coarse sand), including all
charges etc. complete at all, levels, including lettering & fixing
1
-
-
... More
Water Supply and Sanitary Works
-
-
-
... More
17.7.1
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32
mm C.P. brass waste of standard pattern, including painting of fittings and brackets,
cutting and making good the walls wherever require:White Vitreous China Wash
basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
2
-
-
... More
17.10.2.1
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983
with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and
brackets, cutting and making good the walls wherever required:
Kitchen sink without drain board610x510 mm bowl depth 200 mm
1
-
-
... More
17.2.1
Providing and fixing white vitreous china pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including
flush pipe, with manually controlled device (handle lever), conforming to IS : 7231,
with all fittings and fixtures complete, including cutting and making good the walls
and floors wherever required:W.C. pan with ISI marked white solid plastic seat and
lid
2
-
-
... More
18.53.1
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of
approved quality conforming to IS: 893115 mm nominal bore
4
-
-
... More
17.28.2.1
Flexible pipe32 mm dia
2
-
-
... More
50.17.1.5
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make )
including cost of materials and labour charges etc complete as per the direction of site
Engineer-in-charge.
1
-
-
... More
17.32.3
Providing and fixing mirror of superior glass ( of approved quality) and of required
shape and size with plastic moulded frame of approved make and shade with 6 mm
thick hard board backing :Oval shape 450x350 mm (outer dimensions)
2
-
-
... More
18.54.4
Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal
bore, 90 mm long, weighing not less than 93 gms
4
-
-
... More
18.58.2.1
Providing and fixing PTMT grating of approved quality and colour.
Rectangular type with openable circular lid150 mm nominal size square 100 mm
diameter of the inner hinged round grating
2
-
-
... More
17.73.2
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats
with CP brass screws with concealed fitting arrangement of approved quality and
colour600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighting not less than 190 gms
2
-
-
... More
18.65
Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102
mm, height of 75 mm with concealed fittings arrangements, weighing not less than
106 gms.
2
-
-
... More
50.18.8.2.2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge.
Concealed work, including cutting chases and making good the wall etc. 20 mm pipe
10 Kgf/ cm2
5
-
-
... More
50.18.9.2.1
Providing and fixing PVC pipes includings jointing of pipes with one step PVC
solvent cement, trenching, refilling & testing of joints as per direction of Engineer in
Charge.20 mm dia 12 Kgf/cm2
10
-
-
... More
50.18.9.3.1
Providing and fixing PVC pipes includings jointing of pipes with one step PVC
solvent cement, trenching, refilling & testing of joints complete as per direction of
Engineer in Charge 25 mm dia 12Kfg/cm2
10
-
-
... More
50.18.7.3.2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm
dia 10Kgf/ cm2- Internal work- Exposed on wall
12
-
-
... More
50.18.7.4.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm
dia 10Kgf/cm2- Internal work - Exposed on wall
12
-
-
... More
50.18.8.6.2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step PVC solvent
cement and testing of joints complete as per direction of Engineer-in-Charge.
Concealed work, including cutting chases and making good the wall etc. 50 mm pipe
6 kgf/cm2
5
-
-
... More
50.18.9.6.2
Providing and fixing PVC pipes includings jointing of pipes with one step PVC
solvent cement, trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. 50 mm dia 6 Kgf/cm2
10
-
-
... More
50.18.8.7.1
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes with one step PVC solvent cement and
testing of joints complete as per direction of Engineer-in-Charge. Concealed work
including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
4
-
-
... More
50.18.9.20.1
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 63 mm dia Elbow
2
-
-
... More
50.18.9.20.4
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 63 mm dia Bend
1
-
-
... More
50.18.9.20.5
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes
including jointing with PVC solvent cement - 63x63x63 mm dia Tee
1
-
-
... More
50.18.9.20.7
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 63 mm dia vent cowl
1
-
-
... More
50.18.9.20.10
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 63x50 mm dia Reducer
1
-
-
... More
50.18.8.9.2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes with one step PVC Solvent cement and
testing of joints complete as per direction of Engineer-in-Charge. Concealed work,
including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
5
-
-
... More
50.18.9.19.2
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m
spacing. This includes jointing of pipes with one step PVC solvent cement and testing
of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 -
External work - Exposed on wall
10
-
-
... More
50.18.9.22.1
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 110 mm dia Elbow
1
-
-
... More
50.18.9.22.2
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
1
-
-
... More
50.18.9.22.4
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,
including jointing with PVC solvent cement- 110 mm dia Bend
2
-
-
... More
50.18.9.22.5
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes
including jointing with PVC solvent cement 110x110x110 mm dia Tee
2
-
-
... More
50.18.9.22.6
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,
including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
1
-
-
... More
18.32.1
Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar
1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm
(inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2
coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation,
foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm
nominal size) and inside plastering with cement mortar 1:3
(1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement
complete as per standard design:With common burnt clay F.P.S (non modular) bricks
of class designation 7.5
2
-
-
... More
18.48
Providing and placing on terrace (at all floor levels) polyethylene water storage tank
:ISI 12701 marked, with cover and suitable locking arrangement and making
necessary holes for inlet, outlet and overflow pipes but without fittings and the base
support for tank
1500
-
-
... More
Electrification Works
-
-
-
... More
1.10.3
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC
conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
45
-
-
... More
90.3.21.3
Supply & installation of light fittings on 'C/U' shaped flat iron bracket
Supply, conveyance, installation, testing and commissioning the light fittings of
following types made from 0.5mm CRCA sheet complete with all accessories and
lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat,
painting the flat iron bracket and giving connections with required length of
16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or
extending the original wiring and giving connection etc. as required.1200 mm
1X20W LED Lamp with box type fixture
5
-
-
... More
90.4.5.4
Supply, Installation, testing and commissioning of ceiling fan of following sizes
including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm
FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub
meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding
suitable for 230V/240V single phase AC supply
5
-
-
... More
90.3.18.1
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent
to shape / cut and welded to shape and fixing the same to wall / parapet using clamps
as noted along with each size, painting with 2 coats of synthetic enamel paint over a
coat of zinc chromate primer, making good the damages, colour washing etc as
required.25 mm dia with HG company fabricated clamps
5
-
-
... More
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per
IS 732 as required.
5
-
-
... More
1.25
Supplying and fixing two module stepped type electronic fan regulator on the existing
modular plate switch box including connections but excluding modular plate etc. as
required.
5
-
-
... More
1.58
Supplying and fixing PVC batten/ angle holder including connection etc. as required
12
-
-
... More
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base &
cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
12
-
-
... More
9 1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as required.5/6
amps switch
7
-
-
... More
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as required.3
pin 5/6 amp socket outlet
7
-
-
... More
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as
required.15/16 amp switch
8
-
-
... More
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate
& switch box including connections but excluding modular plate etc. as required.6
pin 15/16 amp socket outlet
6
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB DB
complete with connections, testing and commissioning etc. as required.Single pole
6
-
-
... More
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete
etc. as required.
5
-
-
... More
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing
MCB DB complete with connections, testing and commissioning etc. as required.40
amps
3
-
-
... More
2.14.2
Supplying and fixing following rating, double pole, (single phase and neutral), 240
volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in
the existing MCB DB complete with connections, testing and commissioning etc. as
required.40 amps
1
-
-
... More
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB
distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,
neutral bus bar, earth bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
... More
1.21.1
Supplying and fixing of following sizes of medium class PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.20 mm
42
-
-
... More
1.21.2
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in
case of recessed conduit as required.25 mm
20
-
-
... More
1.17.1
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x
1.5 sq. mm
40
-
-
... More
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x
2.5 sq. mm
48
-
-
... More
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
2.5 sq. mm
22
-
-
... More
1.17.21
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x
4 sq. mm
18
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X
1.5 sq.mm
36
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with
wiring/ cables and giving connection as required3.15 mm copper conductor ( 10
SWG)
11
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth
conductor including crimping etc. as required.3.15 mm (10 SWG)
4
-
-
... More
5.11
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth
electrode including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
8
-
-
... More
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including
accessories, and providing masonry enclosure with cover plate having locking
arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as
required.
1
-
-
... More
EXCLUSIVE OF GST
-
-
-
... More
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
-
-
-
... More
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
-
-
-
... More
3.Rate should be Exclusive of GST.
-
-
-
... More
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
-
-
-
... More
5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
-
-
-
... More
6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
-
-
-
... More
7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
-
-
-
... More
8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
-
-
-
... More
9. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
-
-
-
... More
10.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS.
-
-
-
... More
11.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
-
-
-
... More
Make of Electrical equipments/materials
-
-
-
... More
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
-
-
-
... More
12.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
-
-
-
... More
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
-
-
-
... More
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
-
-
-
... More
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
-
-
-
... More
13.VETRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
-
-
-
... More
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
-
-
-
... More
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
-
-
-
... More
14. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
-
-
-
... More
15.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
-
-
-
... More
16. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
-
-
-
Evaluation Notes How It Works ?