Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 22,401Document Cost
₹ 1,792Tender Fee
Refer Documents
Summary
Mla-ads 2023-24 Thrippunithura Lac-sitc Of 10 Mtr Highmast With 200wx6 Led Flood Light At Edakochi Kannangatt Bhagavathi Kshetram, Sitc Of 8 Mtr Minimast With 150wx5 Led Flood Light At 40 Adi Road Junctionin Cochin Corporation With 3 Year Warranty
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KEL_688995_1Bid Award Id
ViewTender No
KEL/KMEP/EPROC/001-R1/2024- 25Tender Authority
Kerala Electrical And Allied Engineering Company Limited ViewPurchaser Address
-Website
http://https://www.kel.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40
nominal size)
0.51
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
219.27
-
-
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of
columns, etc for mass concrete
14.76
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
3.58
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers notexceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
4.74
-
-
ELECTRICAL WORK
-
-
-
Supply installation testing and commissioning of High Mast Pole 20side Polygonal made single/two
sections of hot dip galvanised GI sheet 100mm top diameter, 310mm bottom diameter thickness 3mm
suitable for wind speed as per IS 875 Part III with head frame assembly two/three point suspension
system with steel wire rope 5mm dia double drum winching system and including round arm galvanized
luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4/6 nos fixed in existing RCC foundation and junction box etc, complete 10 Meters
3
-
-
Installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
18
-
-
Supply and installation of twin unit aviation LED obstruction light with stand yellow- painted die-cast
aluminum alloy housing,red coloured polycarbonate dome and BC/ EC lamp holders suitable for LED
lamp.
3
-
-
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm
45
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
3
-
-
Supplying and laying 25 mm X 3 mm G.I strip at 0.50 metre below ground including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
15
-
-
Supply of Syntex Make Panel suitable to install Meter for electricity supply and other accessories made out of Sheet Moulding Compound (560 x 280x 150 mm size) Surface mounted or recess-in wall
(Indoor/Outdoor Use) One piece moulded SMC base and SMC door with internal hinges. Knockout for wire entry, earthing bolt. Includes Contactor, MCB , Connector, Digital Timer, RCCB, HRC Fuse Base
with HRC Fuse link, 2 Way neutral links, Earth Wire, Banana Al. socket, 2.5 sq. mm ISI marked, FRLS
PVC insulated, single core copper conductor cable
3
-
-
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
30
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
18
-
-
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
9
-
-
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm
21
-
-
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of
HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
21
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
9
-
-
Supply and fixing of Name Board of MLA, with Angles ,Flats, Square Pipe, ACP Sheet (complete 4 sides) including Nut and bolt
3
-
-
Supply and fixing of Granite Plaque engraved with the name of MLA , name of Project,Name of Plan,
Location, Name of LSGD ,Year of Project, Estimate Cost and Name of implementing agency.
3
-
-
Annexure B- 02 Numbers of 08 Meter Oct Pole minimast Lights with 5*150 W LED Flood Lights
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated
earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of
soil
2.6
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 nominal size)
0.16
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
71.63
-
-
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
7.2
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1.09
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
3.85
-
-
ELECTRICAL WORK
-
-
-
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet
70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm
suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage
suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4
nos existing RCC foundation and junction box etc, complete 8 Meters
2
-
-
Installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor
greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast
Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98,
RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly
accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced
mentioning chip manufacturer)
10
-
-
Supply of Syntex Make Panel suitable to install Meter for electricity supply and other accessories made
out of Sheet Moulding Compound (560 x 280x 150 mm size) Surface mounted or recess-in wall (Indoor/Outdoor Use) One piece moulded SMC base and SMC door with internal hinges. Knockout for wire entry, earthing bolt. Includes Contactor, MCB , Connector, Digital Timer, RCCB, HRC Fuse Base with HRC Fuse link, 2 Way neutral links, Earth Wire, Banana Al. socket, 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
2
-
-
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
20
-
-
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
20
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
18
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
(but without charcoal/ coke and salt ) as required.
2
-
-
Supplying and laying 25 mm X 3 mm G.I strip at 0.50 metre below ground including connection/
terminating with G.I. nut, bolt, spring, washer etc. as required.
12
-
-
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
6
-
-
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling
the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 10 sq mm
10
-
-
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.2 X 10 sq. mm (19mm)
3
-
-
Supply and fixing of Name Board of MLA, with Angles ,Flats, Square Pipe, ACP Sheet (complete 4 sides)
including Nut and bolt
2
-
-
Supply and fixing of Granite Plaque engraved with the name of MLA , name of Project,Name of Plan,
Location, Name of LSGD ,Year of Project, Estimate Cost and Name of implementing agency
2
-
-
EXCLUSIVE OF GST
-
-
-
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
-
-
-
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
-
-
-
3.Rate should be Exclusive of GST.
-
-
-
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
-
-
-
5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
-
-
-
6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
-
-
-
7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
-
-
-
8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
-
-
-
9. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
-
-
-
10.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS.
-
-
-
6.VETRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
-
-
-
15.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
-
-
-
10.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
-
-
-
9. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
-
-
-
11.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
-
-
-
Make of Electrical equipments/materials
-
-
-
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
-
-
-
Panel Boards: CPRI certified reputed manufacturers make
-
-
-
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
-
-
-
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
-
-
-
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
-
-
-
Cable Glands & Sockets - REPUTED MAKE , Cosmos
-
-
-
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
-
-
-
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements