Kerala Electrical And Allied Engineering Company Limited Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_KEL_726523_1Bid Award Id
ViewTender No
KRO/BDC/1802/2025Tender Authority
Kerala Electrical And Allied Engineering Company Limited ViewPurchaser Address
-Website
http://https://www.kel.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
37.6
-
-
... More
100.7.1 : Bailing out water with 5 HP engine and pumpset including conveyance to the site, errection, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc. complete.
NEW DATA (Prepared based on PHED SDB - Item No.1070
48.49
-
-
... More
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
15.23
-
-
... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
13.78
-
-
... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
237.4
-
-
... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
8.7
-
-
... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
108.12
-
-
... More
19.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
9
-
-
... More
50.18.9.9.2 : Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
217
-
-
... More
4.1.2 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1/2:3 (cement : 11/2 coarse sand : 3 graded stone aggregate 20 mm nominal size)
4.87
-
-
... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.94
-
-
... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
24.91
-
-
... More
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
3.65
-
-
... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
3450
-
-
... More
13.4.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand)
239.23
-
-
... More
13.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
104.3
-
-
... More
19.18.2 : Supplying and fixing C.I with out frame for manholes:500 mm diameter C.I. (medium duty) the weight of the cover to be not less than 58 kg
11
-
-
... More
50.6.3.1 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete
9.2
-
-
... More
22.24 : Providing and applying integral crystalline (dry shake) of hydrophilic in nature for
waterproofing treatment to the RCC structures like basement raft, foundation slab,
sewage & water treatment plant slab, warehouses floor, parking structures and water
tank base slab etc. sprinkled @0.60kg per sqm or higher as recommended by the
manufacturer's specification over the lean concrete of above cited structures. The
material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing
permeability of concrete by more than 85%, compared control concrete as per DIN
1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline dryshake
shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall
be carried out all complete as per specification and the direction of the Engineer-incharge.
The product performance shall carry guarantee for 10 years against any leakage.
159.08
-
-
... More
10.5.1 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
2.52
-
-
... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
2.25
-
-
... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
2.41
-
-
... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
1.8
-
-
... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
168.77
-
-
... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
168.77
-
-
... More
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
143.51
-
-
... More
50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
50.23
-
-
... More
51.20 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required.
36
-
-
... More
10.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
130.49
-
-
... More
Plumbing and Mechanical Works
-
-
-
... More
od124847/2023_2024 : Supply, installation, testing and commissioning of Bucket type coarse bar screen of SS 304 construction using SS Mesh of 8-10 mm Mesh Size, fixed in the Collection Tank with SS Bolt, nut etc. As per direction by the engineer in charge
1
-
-
... More
od124848/2023_2024 : Providing, fixing, testing & commissioning of surface mounted, self priming, centrifugal, Horizontal, non-clog type water pumps(Effluent Transfer Pump). The pump shall have non clog casting & Browns Impeller, TEFC induction motor including pressure gauge complete as required. Accessories : Base plate, Coupled/Monoblock, priming arrangement, mechanical seal, pressure gauge with isolation cock etc.. The pump shall be suitable for 415 & 10% volts 3 phase AC supply complied. Flow rate (each) : 500 LPH, 0.5 Hp, 3phase. Head : 8-11 MLC Type : Open type centrifugal.
2
-
-
... More
od124849/2023_2024 : Providing, fixing, testing & commissioning of fully submersible, centrifugal non-clog type Waste water handling pumps capable of handling solids up to 35 mm for waste water transfer from collection tank to anaerobic tank. The pump shall have non clog casting & impeller: CI, SS shaft. Motor Housing SS304 Accessories : , coupling nylon rocks for lifting etc...complied. Waste Water Transfer Pumps: Flow rate (each) : 500-1000 LPH, 1-1.5 Hp, 3phase. Head : 8-12 MLC. Solid Handling = 35 mm. Type : Open type centrifugal
2
-
-
... More
od124850/2023_2024 : Supply, erection, testing and commissioning of Anaerobic sheet in anaerobic tank with all accessories. The sheets shall be neatly pasted and packed tightly as per the guidelines from the engineer in charge. Surface area of the sheet is 102 m2/m3 Dimension : 1.2 (L) x 0.6(W), MoC: PVC
2
-
-
... More
od124851/2023_2024 : Supply & filling of MBBR Media in Aeration tank as per the direction of Engineer in Charge, Surface Area of the media is 600m2/m3, Size 12mm x 25 mm, MOC: Virgin PE, Color : White, Specific Gravity : 0.94 g/cc, Media Quantity : 99000-100000 Nos/Cum
1.8
-
-
... More
od124852/2023_2024 : SITC of Twin lobe Type Rotary Air Blowers with casing –CI, shaft-Alloy Steel, capable of delivering 20 cum/hr (each) of free air coupling to a TEFC motor of suitable HP suitable for 415 ± 10% volts, 3 phase, 0 cycles A/C supply complete with following accessories installed in RCC foundation with suitable size foundation bolts complete as required. Common base frame for motor & compressor with motor base plate and Belt tightening arrangement etc. Air Suction and Discharge companion flanges. Suction Silencer with Suitable Flanges. Suction Air Filter (Dry Bag Type).Pressure gauge and pressure relief valve (Spring loaded type)<.Compressor & motor pully/coupling with guard. Capacity : 20 m3/hr. Head = 0.35 bar.
2
-
-
... More
od124853/2023_2024 : SITC of squirrel cage Motors for air blowers. Motor and blower shall be arranged in a common base frame and connect with pully and belt system.. Power : 1.5 HP. TEFC Type, 3 phase. Motors required ip55 protection.
2
-
-
... More
od124854/2023_2024 : Providing, fixing, testing & commissioning of surface mounted, self priming, centrifugal, Horizontal, non-clog type water pumps(Re-Circulation Pump). The pump shall have non clog casting & impeller, TEFC induction motor including pressure gauge, Suction pipe with coupling connected to be delivery header etc. complete as required. Accessories : Base plate, Coupled/Monoblock, priming arrangement, mechanical seal, pressure gauge with isolation cock etc.. The pump shall be suitable for 415 & 10% volts 3 phase AC supply complied. Flow rate (each) : 1500 LP/hr, 0.5 Hp, 3phase. Head : 8-11 MLC. Type : Open type centrifugal.
2
-
-
... More
od124856/2023_2024 : Providing, fixing, testing & commissioning of surface mounted, centrifugal, Horizontal, non-clog clear water pumps(Filter Feed Pump). The pump shall have non clog casting & impeller, TEFC induction motor including pressure gauge, Suction pipe with coupling connected to be delivery header etc. complete as required. Accessories : Base plate, Coupled/Monoblock, priming arrangement, mechanical seal, pressure gauge with isolation cock etc.. The pump shall be suitable for 415 & 10% volts 3 phase AC supply complied. Flow rate (each) : 1.00 M3/hr, 1-1.5 Hp, 3phase. Head : 25-30 MLC.
2
-
-
... More
od124857/2023_2024 : Supply, installation, testing and commissioning of Multi graded Pressure sand Filter with the capacity of 1-15 klph, operating pressure 3.5 Bar, Maximum Operating Pressure 5 Bar. Vertical Type with 1NB Top Mount Multiport Valve(Filter, Rinse, Backwash Etc.). Multi port Max. Operating Pressure 5 Bar. Media : graded pebble/Silex, Coarse sand or Fine Sand. Accessories : strainers, Pressure gauge etc.
1
-
-
... More
od124858/2023_2024 : Supply, installation, testing and commissioning of Activated Carbon Filter with the capacity of 1-15 klph, operating pressure 3.5 Bar, Maximum Operating Pressure 5 Bar. Vertical Type with 1NB Top Mount Multiport Valve(Filter, Rinse, Backwash Etc.). Multi port Max. Operating Pressure 5 Bar. Media : graded pebble/Silex, Coarse sand or Fine Sand. Accessories : Strainers, Pressure gauge etc.
1
-
-
... More
od124859/2023_2024 : Providing, fixing, testing & commissioning of surface mounted, centrifugal, Horizontal, non-clog clear water pumps(UF Feed Pump). The pump shall have non clog casting & impeller, TEFC induction motor including pressure gauge, Suction pipe with coupling connected to be delivery header etc. complete as required. Accessories : Base plate, Coupled/Monoblock, priming arrangement, mechanical seal, pressure gauge with isolation cock etc.. The pump shall be suitable for 415 & 10% volts 3 phase AC supply complied. Flow rate (each) : 1.2 LPS, 1.5 Hp, 3phase. Head : 25-30 MLC.
1
-
-
... More
od124860/2023_2024 : Supply, installation, testing and commissioning of 1000LPH Ultra Filtration Unit. Consist of one Number of Micron Filter having service flow of 1.2 KLPH with MOC of Housing PP. 2 Nos of Chemical dosing system capacity of 4-5 LPH at 4 bar Pressure with 30 Ltr Chemical Mixing Tank. UF Membrane : Surface Area 25 m2, Qty - 1 Nos, MoC: PVDF or PES, Back Wash Pump with the capacity of 1500LPH @ 20 mtr Head ,1 Nos, MSEP /SS Skid. Accessories : Pressure Gauges 2 Nos, Solenoid Valves 3Nos, Electric Control Panel, Pressure Switch Etc. Pipe and Fittings UPVC
1
-
-
... More
od124861/2023_2024 : Providing, fixing, tesing and commissioning of electronic chemical dosing system comprising of electronic metering pump (with both frequency and stroke length controls to control the dosage rate between 10-100% of rated maximum capacity) virgin HDPE chemical grade solution tank of 50 ltr capacity, necessary injection fitting assembly foot valve cum strainer and suction and delivery tubing etc. up to the point of injection complete in all respects as required. Dosing pump shall be Electronically operated, Mechanically Actuated diaphragm. Dosing Capacity 6 lph. Pressure 4 bar
6
-
-
... More
50.18.7.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
20
-
-
... More
50.18.7.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
32
-
-
... More
50.18.7.6.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall
66
-
-
... More
50.18.9.17.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall
24
-
-
... More
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
18
-
-
... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes
54
-
-
... More
10.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
45
-
-
... More
od124863/2023_2024 : Providing and fixing PVC/GI/MS fittings complete as per direction of Engineer-in-Charge.
1
-
-
... More
od124864/2023_2024 : Fabrication, Installation, testing and commissioning of Flash Mixer, Flocculator and Primary Settling Tank as per the drawing. Thickness of the MS sheet shall be 4 mm, size of the C Channel is 100 mmx 50 mm, Angle size is 50 x 50 x 5mm. Size of the tanks: Flash Mixer: 1.00 x 0.80 x 1 mtr, Flocculator : 1 x 0.8 x 3 mtr, Settling tank 1.25 x 1.25 x 1.5 (SWD)+ 0.50 (CWD) Inside of the MS Tanks shall covered with two layer of FRP Lining and out side of the tank shall coated with Epoxy Paint. Flash mixer & Flocculator shall fixed with a agitator system with SS 304 Stirrer, Gear Box, Motor in a MS Bridge
1
-
-
... More
Electrical work
-
-
-
... More
od124846/2023_2024 : Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of Semi automated electric control panel. The panel should be equipped with all necessary components including suitable starter for motors with overload protection, overvoltage under voltage protection, phase failure protection, Relay, Timer Etc. ON/OFF/TRIP indicator, Main ON/OFF Selector Switches, Phase Indicator, Name Plate etc. Make of Control Switches: L&T, Panel Size 1m x 1 mx 0.3m Minimum, Moc of Pane : GI Powder Coated
1
-
-
... More
90.6.5.3 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.00 sq mm
100
-
-
... More
90.6.5.4 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm
270
-
-
... More
1.23.3 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch
2
-
-
... More
1.23.5 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet
2
-
-
... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
7
-
-
... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
30
-
-
... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
6
-
-
... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
2
-
-
... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
50
-
-
... More
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C
1
-
-
... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1
-
-
... More
od124855/2023_2024 : Electrical works (including supply, installation and termination of cables with suitable size as per the power of pumps with all structural supports, clamps and cable trays as per approved design/specifications, installation shall be relevant Indian standard and PWD specification ).(l lot). As per detailed specifications
1
-
-
... More
Operation and maintanance of ETP for the first year with chemicals and all consumable (without electric current & Water charge)
1
-
-
... More
Operation and maintanance of ETP for the second year with chemicals and all consumable (without electric current & Water charge)
1
-
-
... More
Operation and maintanance of ETP for the third year with chemicals and all consumable (without electric current & Water charge)
1
-
-
... More
EXCLUSIVE OF GST
-
-
-
... More
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
-
-
-
... More
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
-
-
-
... More
3.Rate should be Exclusive of GST.
-
-
-
... More
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
-
-
-
... More
5.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
-
-
-
... More
6.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
-
-
-
... More
7.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
-
-
-
... More
8.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
-
-
-
... More
9.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
-
-
-
... More
10. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
-
-
-
... More
11.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
-
-
-
... More
12. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
-
-
-
... More
13. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
-
-
-
... More
14.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS.
-
-
-
... More
15.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
-
-
-
... More
Make of Electrical equipments/materials
-
-
-
... More
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
-
-
-
... More
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
-
-
-
... More
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
-
-
-
... More
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
-
-
-
... More
Panel Boards: CPRI certified reputed manufacturers make
-
-
-
Evaluation Notes How It Works ?