Kerala Electrical And Allied Engineering Company Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_KEL_568500_1Bid Award Id
ViewTender No
KRO/ BDC/1375/2023Tender Authority
Kerala Electrical And Allied Engineering Company Limited ViewPurchaser Address
-Website
http://https://www.kel.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
2.98
-
-
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
2.62
-
-
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
13.16
-
-
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
0.08
-
-
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
1.44
-
-
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15sup0/sup landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
20.22
-
-
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2031.2
-
-
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
142.98
-
-
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
17.57
-
-
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
5
-
-
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.
5.7
-
-
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge,
in skirting, risers of steps and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white cement mixed with pigment of matching
shade complete.
62.8
-
-
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
1.56
-
-
10.5.1 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
1.68
-
-
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
9.6
-
-
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
1218.24
-
-
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
1800
-
-
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
211.52
-
-
od334188/2022_2023 : Providing and fixing 15 cm wide semi circular PVC Rain Water gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.
32.2
-
-
50.18.8.8.2 : Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2
28
-
-
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
211.52
-
-
12.45.1 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum plain board conforming to IS : 2095-Part 1
42.01
-
-
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
205.2
-
-
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
264.61
-
-
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections
as per the architectural drawings and approved shop drawings , the aluminium
quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder
coating of 60-80 microns conforming to AAMA 2604 of required colour and shade
as approved by the Engineer-in-Charge. ( The item includes cost of material such
as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium
frame work. Nothing extra shall be paid on this account).
47.25
-
-
25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with
Aluminium Composite Panel Cladding, with open grooves for linear as well as
curvilinear portions of the building , for all heights and all levels etc. including:
a) Structural analysis & design and preparation of shop drawings for pressure
equalisation or rain screen principle as required, proper drainage of water to make
it watertight including checking of all the structural and functional design.
b) Providing, fabricating and supplying and fixing panels of aluminium composite
panel cladding in pan shape in metalic colour of approved shades made out of
4mm thick aluminium composite panel material consisting of 3mm thick FR grade
mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The
aluminium composite panel cladding sheet shall be coil coated, with Kynar
500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour
and shade on face # 1 and polymer (Service) coating on face # 2 as specified using
stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer
rods etc.
c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised
with serrations and serrated washers to arrest the wind load movement, fasteners,
SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to
prevent bi-metallic contacts all complete required to perform as per specification
and drawing The item includes cost of all material & labour component, the cost of
all mock ups at site, cost of all samples of the individual components for testing in
an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall
with aluminium composite panel cladding till the handing over of the building for
occupation. Base frame work for ACP cladding is payable under the relevant
aluminium item.s The Contractor shall provide curtain wall with aluminium
composite panel cladding, having all the performance characteristics all complete
, as per the Architectural drawings, as per item description, as specified, as per the
approved shop drawings and as directed by the Engineer-in-Charge.
However, for the purpose of payment, only the actual area on the external face of
the curtain wall with Aluminum Composite Panel Cladding (including width of
groove) shall be measured in sqm. up to two decimal places.
31.5
-
-
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
51
-
-
21.1.2.1 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
51
-
-
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
9.39
-
-
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
3.36
-
-
21.16.2 : Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-Charge.Powder coated minimum thickness 50 micron aluminium
12
-
-
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete
2
-
-
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
2
-
-
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
2
-
-
9.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mm
12
-
-
17.7.2 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
2
-
-
18.58.1.1 : Providing and fixing PTMT grating of approved quality and colour.Circular type100 mm nominal dia
2
-
-
50.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
10
-
-
50.18.8.7.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc 63 mm pipe 4 kgf/ cm2
10
-
-
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
2
-
-
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
1
-
-
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
1
-
-
50.18.8.3.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2
15
-
-
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall
10
-
-
50.18.8.4.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2
5
-
-
50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall
10
-
-
od327927/2022_2023 : Providing and fixing Laterite wall cladding tiles , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
37.5
-
-
od327930/2022_2023 : Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages.
2
-
-
od334440/2022_2023 : Extra for providing frosted glass film in doors.
10.4
-
-
od334441/2022_2023 : Supplying and fixing Stainless steel Five tier wire shelving unit of dimension 120x50x180cm size
3
-
-
od334442/2022_2023 : Supplying and fixing GODREJ STOREWELL (Almirah)91.44x45x198cm size
2
-
-
$Electrical Works
-
-
-
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
280
-
-
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
5
-
-
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in
recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps
modular switch, connection etc. as required. (For light plugs to be used in non residential
buildings).
2
-
-
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
5
-
-
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
20
-
-
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
20
-
-
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing
masonry enclosure with cover plate having locking arrangement and watering pipe etc. with
charcoal/ coke and salt as required
2
-
-
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
25
-
-
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
20
-
-
90.12.7.27 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
25
-
-
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
4
-
-
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
20
-
-
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
4
-
-
od327952/2022_2023 : Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required. .63A 10KA TP MCB (C curve)
4
-
-
od328166/2022_2023 : "Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required. .40A 10KA TP MCB (C curve) "
3
-
-
od330606/2022_2023 : "Supply, testing and commissioning of the following Armoured copper cable-.4c x 6 sq.mm".
140
-
-
od330674/2022_2023 : "Supply, testing and commissioning of the following Armoured copper cable-.4c x 10 sq.mm".
140
-
-
od328220/2022_2023 : Providing and fixing 4.00 mm (8 SWG ) dia copper wire on surface or in recess for loop earthing as required.
280
-
-
od328221/2022_2023 : SITC of 1200 mm sweep Ceiling fan with metallic blade and base along with necessary accessories for fixing etc as required.
2
-
-
od328222/2022_2023 : 'SITC of 220 mm Exhaust fan with blade and base along with necessary accessories for fixing etc as required
2
-
-
od328223/2022_2023 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof 4-pole enclosure including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / isolator etc fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc as required.
6
-
-
od331006/2022_2023 : Supplying and fixing suitable size Gl box with modular plate and cover in Front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required..
2
-
-
od331007/2022_2023 : Supplying and fixing of following sizes of flexible conduit along with accessories in surface/recess as required. (16/ 20mm.).
20
-
-
od331008/2022_2023 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 5 X 25 sq. mm + 1X 25 sq. mm earth wire.
30
-
-
od331009/2022_2023 : "SITC of 40 KVA UPS System.Socomec 40kva UPS Masteries GP 4 3/3 True online Double Conversion UPS System.• Output Power Factor Rating (Unity).• High input power factor correction @0.99.• I THD < 2.5%.• Advanced Software for monitoring UPS.• Battery test/Battery Replace &Silence.• Wide Input Voltage range.• Efficiency upto 96%.• IGBT Rectifier.• Pure sine wave output.42AH /40 NOS SMF AMARON/QUANTA with cable.Accessories, DC Breaker and uninivine cables and copper socket".
1
-
-
od331032/2022_2023 : Supply, conveyance, installation, testing and commissioning the following types of light fittings with all accessories directly on wall / in existing false ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required. 20W LED Tube light.
5
-
-
HVAC PHASE 2
-
-
-
od331861/2022_2023 : "OUTDOOR UNITS:.Supply of aircooled Outdoor condensing unit with Digital scroll compressor as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll compressor,electronic microprocessor pendant controller with digital display, first charge R 410 A refrigerant gas, vibration isolator pads and safety devices like thermal protector, pressure relief valve, over load relays single phase prevention, high-low pressure cut out, suitable for three phase 415V supply etc as required..14 HP (OT 1, OT 2)".
2
-
-
od331862/2022_2023 : "OUTDOOR UNITS:.Supply of aircooled Outdoor condensing unit with Digital scroll compressor as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll compressor,electronic microprocessor pendant controller with digital display, first charge R 410 A refrigerant gas, vibration isolator pads and safety devices like thermal protector, pressure relief valve, over load relays single phase prevention, high-low pressure cut out, suitable for three phase 415V supply etc as required..12 HP (OT 3)".
1
-
-
od331863/2022_2023 : "DOUBLE SKIN AHU.Supply of Double skin AHU Pre-Plasticised Sheet/ powder coated Mixing box, Extruded Aluminium panta post frame work, Fan section, coil section, filter section with Pre filter and Fine filter, necessary insulations, drain pan, etc. arrangements of follwoing capacity..2800 CFM -( OT1, OT 2)".
2
-
-
od331864/2022_2023 : "DOUBLE SKIN AHU.Supply of Double skin AHU Pre-Plasticised Sheet/ powder coated Mixing box, Extruded Aluminium panta post frame work, Fan section, coil section, filter section with Pre filter and Fine filter, necessary insulations, drain pan, etc. arrangements of follwoing capacity..2200 CFM - OT3".
1
-
-
od331865/2022_2023 : "AHU CONNECTING KIT.Supply of AHU Connecting kit suitable for AHU".
3
-
-
od331866/2022_2023 : "AHU STARTER PANEL.Supply of starter panel suitable for AHU with interlink of AHU kit with wired remote".
3
-
-
od331867/2022_2023 : "DUCT MOUNT HEATER AND PANEL.SITC of Humidity Controller electric strip heaters in supply air plenum complete with fixing arrangements humdistat and safety thermostat including control panel and all supports, terminations, power and control wiring for the following".
3
-
-
od331868/2022_2023 : "REFRIGERANT PIPE.Supply, installation, testing and commissioning of interconnecting insulated copper tubing, for refrigerant liquid and suction lines between the Outdoor and Indoor Units complete, including fittings like elbows, reducers etc. and suitable wall / ceiling clamps as required for the complete installation and proper functioning of the system. The suction lines shall be insulated with 19 mm thick and discharge lines shall be insulated with 13mm closed cell nitrile rubber flexible hose insulation.".
30
-
-
od331869/2022_2023 : "ELECTRICAL CONTROL CABLING.Supply, installation, testing and commissioning, Transmission/Communication cabling, of 2Cx1.5 Sqmm non polar shelied cable for interconnecting the Indoor and Outdoor Units for proper performance , Communication cable must be routed throgh PVC pipe.".
36
-
-
od331870/2022_2023 : "DRAIN PIPING.Supply, installation, testing and commissioning of drain piping of hard PVC pipe and fittings, insulated with 9 mm thick nitrile rubber.".
15
-
-
od331871/2022_2023 : REFRIGRANT GAS.
15
-
-
od331872/2022_2023 : "ALUMINIUM DUCTING AND INSULATION-Supply, installation balancing and commisnioning of Aluminium rectangular.ducting as per approved drawings & specification of following sheet thickness.Thickness 22 Gauge".
120
-
-
od331873/2022_2023 : "ALUMINIUM DUCTING AND INSULATION-Supply, installation balancing and commisnioning of Aluminium rectangular.ducting as per approved drawings & specification of following sheet thickness.Thickness 20 Gauge".
30
-
-
od331874/2022_2023 : "ALUMINIUM DUCTING AND INSULATION-Supply, installation & testing of Acoustic Insulation of ducts using opencell processed nitrile rubber having a density of 140-180 Kg/m3 and with anti-microbial protection.10 mm".
40
-
-
od331875/2022_2023 : "Supplying and fixing of following thickness closed cell Anti Microbial Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.13mm"
150
-
-
od331876/2022_2023 : "SHIFTING, ERECTION, TESTING AND COMMISSIONING INCLUDING.PRESSURE TESTING, VACUUMISATION.-14 HP (OT 1, OT 2)".
2
-
-
od331877/2022_2023 : "SHIFTING, ERECTION, TESTING AND COMMISSIONING INCLUDING.PRESSURE TESTING, VACUUMISATION.-12 HP (OT 3)".
1
-
-
od331878/2022_2023 : Supply of ultra clean laminar air pleanum (2000x2100x400) with 8 Nos of imported minipleat hepafilters of size 600x600x75 flange type efficiency 99.97% H13 imported microfine glass fibre media. The plenum side wall made of 1 mm SS 304 Grade and top with 1.2 mm thick Nalco/Hindalco Aluminium. Filter brackets are made of 40x40x3.3 mm SS 304 Profiles. Perforated terminal grills using 0.8 mm thick SS 304 grade.
2
-
-
od331879/2022_2023 : Supply of ultra clean laminar air pleanum (2000x2100x400) with 6 Nos of imported minipleat hepafilters of size 600x600x75 flange type efficiency 99.97% H13 imported microfine glass fibre media. The plenum side wall made of 1 mm SS 304 Grade and top with 1.2 mm thick Nalco/Hindalco Aluminium. Filter brackets are made of 40x40x3.3 mm SS 304 Profiles. Perforated terminal grills using 0.8 mm thick SS 304 grade.
1
-
-
MODULAR OT-PHASE-02
-
-
-
od331880/2022_2023 : Hermetically Sealing type of Automatic Sliding Door of size 1500 X 2100 mm single / dual leaf with PUF core sandwiched between Antimicrobial High Pressure laminates (HPL), with viewing window of size 300 X 300 mm. The door leafs hung on extruded heavy duty aluminium alloy extrusion Doorframe for single side swing Doors, Sliding Door leafs runs on (nylon wheels) within an extruded heavy duty aluminium alloy extrusion track / frames, for smooth effortless sliding with the help of handle..
3
-
-
od331881/2022_2023 : HPL finish (5mm thickness sheets) - 3 feet swing door PUF FILLED DOOR - 50MM Thick and with all standard accessories….
2
-
-
od331882/2022_2023 : "Supply, Install, Testing and Commissioning of MEMBRANE TYPE Surgeon control panel including of all fittings & fixtures complete, mounted flush in the operation theatre wall along with Distribution board provided to allow access to the panel for maintenance. Each control panel consists of following:.Day time digital clock -01 no..Elapsed time digital clock- 01 no.Hands free telephone – 01 no.Medical Gas Alarm ( 5 gas).Temperature, Differential Pressure & Humidity display - 01 no.".
3
-
-
od331883/2022_2023 : X Ray view box - Double plate dimmable X Ray viewing screen with 30 watt LED light source.
3
-
-
od331884/2022_2023 : Writing board of size 950x650mm comprises of a flush mounted, 1.50mm thick, white laminate board, bonded to a 10mm high density fibreboard sheet for additional rigidity complete .
3
-
-
MEDICAL GAS PHASE -02
-
-
-
od331885/2022_2023 : Nitrous oxide manifold.
1
-
-
od331886/2022_2023 : Compressed Air plant-3HP with receiver and accessories.
1
-
-
od331887/2022_2023 : Bedhead unit 1 Mtr long.
7
-
-
BIOMEDICAL WORK
-
-
-
od331888/2022_2023 : " Automatic Double Station Surgical Scrub Sink. * Completely Made of Stainless Steel 304 Grade .Mat # 4 Finish Sheets & Tubes .* High Back Splash. .* Perforated Drain Board. *Two No of Sensor Operated Water Flow Control * Two No of Foot Operated Water Flow System. * Two No of Lbow Operated Soap Dispenser. *Front Panels are Easily Openable for Maintenance.".
1
-
-
od331889/2022_2023 : Double Station Instrument Washing Sink Table. Custom Fabricated Stainless Steel Instrument Washing Counter with Back Splash and Three Side Lippings.Completely made of stainless steel 304 grade Mat#4Finish Sheets and Tubes.Instrument Washing Sink Should Have Two Washing SinkHaving Minimum Over all Dimension of 1500x600x900+150mm LxWxH. One no of Water Gun with Spiral PU Tube..
1
-
-
od331890/2022_2023 : PASS box ss 600X600.
3
-
-
Site Fabrication and Installation Charges (Modular OT)
1
-
-
EXCLUSIVE OF GST
-
-
-
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
-
-
-
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
-
-
-
3.Rate should be Exclusive of GST.
-
-
-
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
-
-
-
5.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
-
-
-
6.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
-
-
-
7.STEEL REINFORCEMENT: Make: Tata,Vaishak, SAIL, JSW or eq primary make in the order of preference
-
-
-
8.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
-
-
-
9. SOLID BLOCK MASONRY: Min. average compressive strength as per IS shall be 40-50kg/cm2 and has to be assessed by testing at Govt. lab. ( Variation in rate due to change in size of block and level of floor as per DSR/PRICE has to be considered)
-
-
-
10.PLUMBING & SANITARY FITTINGS: Note: Make of Water supply and sanitary items: Best branded ISI make Jaquar, Cera, Hindware, Parryware or eq. in the order of pref. Water pipe: Supreme, Finolex or eq. with IS and all fittings with IS.
-
-
-
11.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
-
-
-
Make of Electrical equipments/materials
-
-
-
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
-
-
-
Panel Boards: CPRI certified reputed manufacturers make
-
-
-
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
-
-
-
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
-
-
-
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
-
-
-
Cable Glands & Sockets - REPUTED MAKE , Cosmos
-
-
-
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
-
-
-
12.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
-
-
-
13.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
-
-
-
14.VETRIFIED FLOOR TILES/ CERAMIC GLAZED WALL TILES: Make: Khajaria, Jhonson, RAK, NITCO, Cera or Eq. in the order of preference and prior sample approval from KEL, Client
-
-
-
15.DELUXE MULTI SURFACE PAINT SYSTEM: Make: JOTUN, Asian, Berger, Nerolas or eq. in the order of pref.
-
-
-
16. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements