Kerala Cooperative Milk Marketing Federation Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 20,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_KCMMF_692957_1Bid Award Id
ViewTender No
KCMMF/KHO/PROJ(529)/2024Tender Authority
Kerala Cooperative Milk Marketing Federation Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
15.9.2 Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
7.2
-
-
15.23.1 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
30
-
-
15.28.1 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
10
-
-
15.57 Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
3
-
-
EARTHWORK
-
-
-
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
69.96
-
-
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
12
-
-
50.2.25.1 Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
12
-
-
OD22587/2024-2025 Providing & laying GSB in compacted thickness of 100 mm using stone aggregates of nominal size 65 mm metal shall be spread over the prepared base, consolidated layer in 3 layers as specified, the metal layer dry and wet shall then be rolled and consolidated by a Rammer (8-10T power roller) to achieve consolidated thickness. After the dry Rammer is completed, smaller size stones, grit, quarry dust / sand etc. shall be spread and watered and rolled all as complete and directed by
Engineer in charge.
18
-
-
FOUNDATION
-
-
-
4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
6
-
-
5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
23.74
-
-
5.33.3 Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement content
as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of
concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable
separately.All work above plinth level upto floor V level
1.06
-
-
4.3.2 Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
74.6
-
-
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
2484
-
-
BRICK WORK
-
-
-
OD19615/2024-2025 Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to
floor two level with thickness 20cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
21.64
-
-
FLOORING WORK
-
-
-
OD21083/2024-2025 Providing and laying heavy duty industrial type fully vitrified 20mm thick acid/alkali resistant industrial tile suitable for dairy flooring work. The tile shall be laid with 20mm thick mortar (1:4) bedding with 5 mm spacer joints. The joint shall be filled with approved brand acid/alkali resisting epoxy grout(Grouting the joints of flooring tiles having joints of 5 mm width upto 5mm depth, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-incharge. APPROVED BRAND -JOHNSON ENDURA Size of Tile 300 x 300 mm - Flooring & Skirting
210.36
-
-
FINISHING WORK
-
-
-
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
96.4
-
-
13.19.1 Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 ( 1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 ( 1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement .Ordinary cement finish using ordinary cement
36.5
-
-
13.3.1 20 mm cement plaster of mix:1:4 (1 cement : 4 fine sand)
30.9
-
-
13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
96.4
-
-
13.85.3 Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
98.2
-
-
13.82.2 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour.Two
coats
98.2
-
-
ROOFING WORK
-
-
-
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1400
-
-
od296578/2021_2022 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer and two coat of epoxy paint, including welding and bolted with special shaped washers etc. complete.<br>Hot finished welded type tubes
350
-
-
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
69.96
-
-
OD19627/2024-2025 Providing and fixing Square type 200mm PVC gutter including all cost and conveyance charge etc complete.
12
-
-
12.41.2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
10
-
-
OD22803/2024-2025 Providing and fixing MS chequered plate including painting with two coat of red oxide primer and 2 coat
of synthetic enamel paint of approved make finished to even shades as per the direction of engineer in charge.
47.1
-
-
MISCELLANEOUS WORK
-
-
-
OD22594/2024-2025 Pressure grouting with cement slurry mixed with approved quality water proofing compound 2kg to the existing pit/open surface viz. base slab and side walls at suitable
intervals for arresting leakages in the rain water gutter, Plinth etc.
12
-
-
16.83 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable
material within 50 metre lead as per direction of Engineer-in-Charge.
30
-
-
OD22818/2024-2025 Providing and laying 100 mm thick factory made cement concrete interlocking paver block of M - 40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
15
-
-
OD22613/2024-2025 Providing and fixing SS 304 grade Amul trap of hygienically designed main body with 8mm thick SS 304 grade top plate having 10mm slots. Inside filter shall be circular shape having 8mm dia holes and dia 150mm pipes which is having 25mm holes to filter small particles.
2
-
-
OD22618/2024-2025 Providing and fixing powder coated fully glazed two track two paneled sliding windows made of powder coated aluminium extruded architectural sections of 20mm
series frames 62x39mm bottom gutter, 62x30mm top&side and 39x20mm shutter frame all having wall thickness of 1.5 ± 0.1 mm and glazing with 4mm thick approved reflective type glass including necessory glazing bead of appropriate
dimension, handle, lock, EPDM/Neoprene gasket, screws, fastners etc. as per enclosed technical specifications and drawings. The gap in between aluminium frame and adjacent rcc/brick/stone work shall be sealed by weather silicon sealant over backer rod of approved quality.
9
-
-
OD22819/2024-2025 Providing and fixing panelled side hung doors made of powder coated aluminium extruded architectural sections of 45mm wide frames for shutter having wall thickness of 1.8 ± 0.1 mm and appropriate outer frames with 6mm ACP panel at bottom and 6mm thick approved glass at top including handle, EPDM gasket, screws, fastners, pivots, hinges, lock & key, door stopper etc. as per the drawing and specifications.
4.2
-
-
OD22642/2024-2025 Providing and fixing louvered ventilator made of 6mm thick approved glass fixed to powder coated aluminium extruded frame of size 63.5x38.1x2mm including fastners,
screws etc. complete.
3.6
-
-
50.18.9.10.1 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
10
-
-
22.22 Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc.. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement
concrete at site of work. The material shall meet the requirements as specified in ACI212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
76.8
-
-
18.27.3 Providing and laying S & S centrifugally cast ( Spun) iron pipes ( Class LA) conforming to IS - 1536 :150 mm dia pipe
10
-
-
Providing and laying G.I pipes conforming to IS - 1536 :150 mm dia pipePipe shall confirm IS:13871 (Part –I),IS: 1239-Heavy
(latest edition) , Heavy Duty, Continuous Welded With
Min. Tensile Strength of 32.63 Kgf/sq.mm & Galvanized
Protective Coating to Protect from Corrosion as per IS:
4736 / ASTM A53 or by electro galvanizing, with plain
end. 3mm or greater thickness
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements