Kerala Agricultural University Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Kerala Agricultural University - KAU Tender

Works
Eprocure
Opening Date29 Nov 2018
Closing Date6 Dec 2018
Tender Amount₹ 3,33,197 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Crs Pampadumpara- Rewiring Of Proffessors Quarters-2 Blocks (4 Nos)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring points in surface / semi concealed conduit system (8Points) using 20 mm rigid PVC conduit medium guage with specials and 1mm2 PVC insulated FR SC copper wire. The conduit on the wall shall be clambed using saddles, suitable size modular type flush mounting metal switch boxes duly concealed, modular type of front plated, clip in modular type 6A, SP piano type swich etc. as per IS Specifications and making good the surface as per directions of departmental officers. - Light point excluding ceiling rose

68

-

812

... More
Wiring points in surface / semi concealed conduit system (8Points) using 20 mm rigid PVC conduit medium guage with specials and 1mm2 PVC insulated FR SC copper wire. The conduit on the wall shall be clambed using saddles, suitable size modular type flush mounting metal switch boxes duly concealed, modular type of front plated, clip in modular type 6A, SP piano type swich etc. as per IS Specifications and making good the surface as per directions of departmental officers. - Fan points with suitable regulator box and plate

20

-

918

... More
Wiring points in surface / semi concealed conduit system (8Points) using 20 mm rigid PVC conduit medium guage with specials and 1mm2 PVC insulated FR SC copper wire. The conduit on the wall shall be clambed using saddles, suitable size modular type flush mounting metal switch boxes duly concealed, modular type of front plated, clip in modular type 6A, SP piano type swich etc. as per IS Specifications and making good the surface as per directions of departmental officers. - Wiring call bell / stair case point / two way light point

4

-

1037

... More
Wiring plug points in the above system along with the wiring of light points using 6 Amps, 3 pin multi plug socket clip in modular type and 6 Amps, SP piano type modular switch - In combined position.

4

-

520

... More
Providing 6A, 3 pin multi socket and 6A SP piano type switch attached to the switch board.

24

-

198

... More
Wiring PVC insulated SC copper wire in surface conduit system using suitable rigid PVC conduit with specials, saddles, screws etc as per IS specification. - 1.50 mm2 - 2 run

100

-

98.5

... More
Wiring PVC insulated SC copper wire in surface conduit system using suitable rigid PVC conduit with specials, saddles, screws etc as per IS specification. - 1.50 mm2 - 4 run

50

-

130

... More
Wiring PVC insulated SC copper wire in surface conduit system using suitable rigid PVC conduit with specials, saddles, screws etc as per IS specification. - 2.50 mm2 - 2 run

120

-

117

... More
Wiring PVC insulated SC copper wire in surface conduit system using suitable rigid PVC conduit with specials, saddles, screws etc as per IS specification. - 2.50 mm2 - 4 run

40

-

167

... More
Wiring PVC insulated SC copper wire in surface conduit system using suitable rigid PVC conduit with specials, saddles, screws etc as per IS specification. - 4.00 mm2 - 2 run

40

-

141

... More
Wiring PVC insulated SC copper wire in surface conduit system using suitable rigid PVC conduit with specials, saddles, screws etc as per IS specification. - 4.00 mm2 - 4 run

80

-

216

... More
Supplying and drawing PVC insulated SC copper wire through the existing conduit and giving necessary connection etc. as required.-

400

-

20.5

... More
Supplying and drawing PVC insulated SC copper wire through the existing conduit and giving necessary connection etc. as required. -

250

-

26

... More
Supplying and drawing PVC insulated SC copper wire through the existing conduit and giving necessary connection etc. as required. -

100

-

35

... More
Supplying and drawing PVC insulated SC copper wire through the existing conduit and giving necessary connection etc. as required. -

50

-

47.5

... More
Supply and providing rigid PVC conduits with specials for wiring / protection / service connection pipe in surface conduit system using conduit saddles, screws etc. as per directions of deptl. Officers. -

20

-

61

... More
Supply and providing rigid PVC conduits with specials for wiring / protection / service connection pipe in surface conduit system using conduit saddles, screws etc. as per directions of deptl. Officers. -

10

-

77.5

... More
Supply and providing rigid PVC conduits with specials for wiring / protection / service connection pipe in surface conduit system using conduit saddles, screws etc. as per directions of deptl. Officers. -

10

-

106

... More
Supplying and drawing bare copper earth conductor along with wiring / cable / through pipes etc as required. -

60

-

28

... More
Supplying and drawing bare copper earth conductor along with wiring / cable / through pipes etc as required.

40

-

59

... More
Providing copper earth socket to the copper earth wire and fixing using brass bolt and nut with washer including crimping.

200

-

17.5

... More
Supplying and fixing bakelite / PVC batten holder using suitable MS Box with hylam sheet cover including connection

68

-

265

... More
Providing LED Lamp 6/9 W to the fixtures.

68

-

204

... More
Supply and fixing Call bell Ding Dong type with suitable MS box with hylam sheet cover including connection.

4

-

367

... More
Supply and fixing surface mounted 240V, 18W, 1600 lumens, slim, 4ft, LED, Battern fitting complete with cool white light including connection using FR Multi-core PVC insulated and PVC sheathed copper conductor round flexible wire having 0.75 sq.mm as per direction of dept.officers

24

-

900

... More
Supply and fixing 6/16 A, 3 pin, combined modular type shuttered plug sockets on suitable modular type flush mounting metal switch boxes,modular type front plate etc including connection. -

8

-

654

... More
Supply and fixing 6/16 A, 3 pin, combined modular type shuttered plug sockets on suitable modular type flush mounting metal switch boxes,modular type front plate etc including connection. -

4

-

706

... More
Supply and fixing 6A, multi plug socket modular type with 6A SP modular type switch using suitable modular type flush mounting boxes,modular front palte etc. including connection. - 4 Way

4

-

1370

... More
Supplying and fixing sheet steel phosphatised and painted double cover, dust and vermin proof MCB DB, with busbar, neutral link, earth bus and din rail etc. on wall and making the wall in good finishing. - Three phase - 4 Way (8+12)

4

-

2749

... More
Supplying and fixing RCCB in position including connection. - 40 A Four pole

4

-

2498

... More
Supplying and fixing Mini Break isolator in distribution board enclosure including connection. - 40 Amps - Four Pole.

4

-

856

... More
Supplying and fixing MCB's in position including connection. -

32

-

215

... More
Supplying and fixing MCB's in position including connection. -

5

-

19.5

... More
Providing MS rod type fan clamp suitable for RCC slab neatly painted including chipping the RCC slab and making good surface.

2

-

130

... More
Supply of AC ceiling fan 1200 mm sweep capacitor type with double ball bearing complete with down rod shackle canopies

16

-

1645

... More
Installation, testing and commissioning of A.C. ceiling fan using standard accessories complete, wiring the down rod and giving connection using 3 core 16/0.20 mm PVC insulated and sheathed 3 core flexible copper wire.

16

-

302

... More
Supply and fixing 100W step type fan regulator modular type socket type to the existing switch board

20

-

433

... More
Supply and providing independent ordinary pipe earthing using 50 mm dia GI pipe 1.85 m long suitable GI bolt, nut and washer, filling with charcoal and salt around the pipe including earth work excavation and masonary works required.

4

-

1989

... More
Supply and fixing TPN Switch Disconnector Fuse Unit with fuses, open execution type attached to the existing control panel / additional facilities using suitable metal frame work including connection .- 32Amps TPN

4

-

2656

... More
Providing 32 Amps porcelain cut out (1 No) and neutral link to the energy meter board and giving connection using required length of PVC insulated copper wire.

4

-

251



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.