Kannur International Airport Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_KIAL_493046_1Bid Award Id
ViewTender No
KIAL/ED-ENGG/51/2022/713Tender Authority
Kannur International Airport ViewPurchaser Address
-Website
http://https://www.kannurairport.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Extension Of Existing Kennel To Accommodate Additional Dogs And Dog Handlers At Kannur International Airport
Extension Of Existing Kennel To Accommodate Additional Dogs And Dog Handlers At Kannur International Airport
BOQ Items
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
14
-
-
Centering and shuttering including strutting, proping and removal of the foam for
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
48
-
-
Suspended floors, roofs, landings, balconies and access platform
135
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
16
-
-
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
2463
-
-
Providing and fixing in position factory made precast RCC M 40 fixing with hold fast embedded in 1:3:6 concrete block for door and windows frames having excellent smooth finish as per IS:6523 with reinforcement of 3 Nos, 6mm dia main bars tied with 3mm M S Stirrups placed at 200 mm C/C and 6 numbers high strength polymer blocks of required size of fixing hinges including providing 6mm specially designed M S galvanised sleeves for accomodating fully threaded bolts for fixing hold fast on vertical members, Door frame 100 mm x 60 mm -
51
-
-
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
5
-
-
Providing and fixing factory made uPVC door frame of uPVC extruded sections having with wall thickness 2.00mm corners of the door frame to be jointed with galvanised brackets and stainless steel screws. The hinges side of galvanised M S Tube of size 19mm,. Extruded section profile size 48 x 40 -
6
-
-
Providing and fixing to existing door frames 24mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59 x 24mm and wall thickness 2mm with inbuilt edging on both sides. The styles and rails mitered and joint at the corners by means of M S galvanised brackets of size 75 x 220 mm having wall thickness 1 mm and screwsThe styles of shutters reinforced by inserting galvenised M S tube of size 20 x 20mm. Shutter frame filled with uPVC multi chambered single panel of size not less than 620mm, having overall thickness of 20mm and 1mm wall thick. -
2
-
-
Providing and fixing panelling or paneling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebated to be measured). Panelling for panelled and glazed shutters 25mm to 40mm thick: Pre-laminated with decorative lamination on both
side exterior Grade - I MDF Board 12 mm thick confirming to IS:14587
4
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
291
-
-
Supplying, laying, and jointing schedule 40 UPVC ASTM pipe and Schedule 80 ASTM-UPVC specials of approved make such as tees elbows, unions,bends,sockets bends,flanges, reducers, end caps,saddles, plugs,coupling, etc. including cost of all jointing materials like solvent cement, bolts, nuts, rubber washers,ferrule,pipe supports, cost of extra wastage of fittings during laying of pipe line such as rectification and recharging of the existing line as and when required etc.hire of tools and plant, cost and conveyance of water for testing after connecting to mains including all testing pipe line to the specified hydrostatic test pressure,rectifying any leakage or defects etc. complete.as directed by Engineer-in-Charge for water supply
-
-
-
40MM DIA
10
-
-
20MM DIA
8
-
-
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
80
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
57
-
-
Supplying, laying and jointing hard PVC pipes with PVC specials such as tees, bends, door bend, door tee, elbows,unions, etc. with clamps including cutting and making good the walls,testing the lines rectifying any leakages or defects,etc. complete as directed by the Engineer-in-Charge for soil, waste, rain water,drains, vent pipe, etc. concealed or open at all levels including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge
-
-
-
110 mm OD (6Kg/cm2)
50
-
-
63 mm OD (6Kg/cm2)
20
-
-
50 mm OD (6Kg/cm2)
20
-
-
12 mm cement plaster of mix : 1:6 (1 cement : 6 fine sand)
400
-
-
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
86
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer sqm
330
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
83
-
-
Finishing walls with water proofing cement paint of required shade :
New work (Two or more coats applied @ 3.84 kg/10 sqm)
130
-
-
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand)
5
-
-
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
1
-
-
Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar
0.5
-
-
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
G.S. Sheet
55
-
-
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
150
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
1
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.
1
-
-
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 MM Dia flexible pipe -
1
-
-
Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms -
1
-
-
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
1
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1000
-
-
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
2
-
-
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
1
-
-
Providing and Fixing Aluminium doors, windows and ventilators and partitions with extruded built up std tubular sectons / appropriate z sections conforming to IS:733 and IS: 1285 fixing with fasterners and filling with required EPDM rubber neaprine gaskets etc. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
11
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
5
-
-
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. For vertical surface two coats @ 0.70 kg per sqm
12
-
-
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc.
For horizontal surfacee one coat @1.10 kg per sqm.
4
-
-
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
5
-
-
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm
5
-
-
Providing and fixing ISi marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete :300x20x6 mm
5
-
-
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
3
-
-
Providing and fixing floor trap of PVC, 110mm outer dia (multi trap) including CP cockroch free floor grating with cup etc including cost and conveyance of all materials, labour charges, sundries etc complete as directed by EIC at all levels. - Toilet Construction at ATC.
2
-
-
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
1
-
-
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
1
-
-
Identifying existing Sewer Lines ,Water Supply Lines etc. coming under the proposed construction area and relaying the same as per requirement.Including dismantling ,excavation ..etc
25
-
-
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpetwashers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), including refixing purlins, rafters and trusses and including cutting to size and shape wherever required.
0.63 mm thick with zinc coating not less than 275 gm/ m²
(USING DISMANTLED MATERIAL AVAILABLE AT SITE )
55
-
-
Clearing plot including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
900
-
-
Providing & constructing Laterite masonry in CM 1 :6 with neatly dressed laterite stones of standard / approved size & approved quality (average compressive strength not less than 35 kg /Cm 2 ) including scaffolding ,raking out of joints ,curing,cost & conveyance of all material ,labour lead ,lift etc complete for all type of masonry works in superstructure above the highest plinth level upto floor five level as directed by engineer in charge
85
-
-
Evaluation Notes How It Works ?