Irrigation Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_Irrig_653163_1Bid Award Id
ViewTender No
IRR/PI/13757/2023-2024Tender Authority
Irrigation Department ViewPurchaser Address
-Website
http://http://www.irrigation.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
OD129524/2023-2024:Supply and installation testing and commissioning of inground Tree uplighting luminaire with 36w power consumption and 3600 Lumens in 3000K CCT. Fixture shall be supplied with 20 degree beam angles to achieve required light spread. The housing shall be made of stainless steel ring housing frame and Tempered glass to achieve IP66 & IK08 protection and IP68 Connector for Power connection. Fixture dimention shall be not less than 250mm dia and 162mm height of PhilipsBBP344 LED3600/WW 36W 20D 100-240V or Techno Commercial equivalent in Osram or Keselec.
21
-
-
OD129525/2023-2024:Supply and installation testing and commissioning of inground Tree uplighting luminaire with 8w power consumption and 520 Lumens in 3000K CCT. Fixture shall be supplied with 45 degree beam angles to achieve required light spread. The housing shall be made of diecast aluminium and Tempered glass to achieve IP65 & IK07 protection. The fixture shall be suitable for 360 degree rotation and dimention not less than 60mm dia of Philips BGP150 LED520/WW 8W 45D GM or Techno Commercial equivalent in Osram or Keselec.
5
-
-
OD129526/2023-2024:Supply and installation testing and commissioning of LED Bollards of 14w (+/-2w) power consumption and 900 Lumens light output. The housing shall be made of LM6 grade pressure diecast aluminium housing in square form factor and PC cover to achieve IP66 with IK10 protection. 50,000 burning hours life of Philips BCP400 LED09 D CW PSU GR S1 or Techno Commercial equivalent in Osram or Keselec.
6
-
-
OD129527/2023-2024:Supply and installation testing and commisioning of LED Post Top fitting 45w (+/-3w) having greater than 4600 lumens light output in 3000K CCT. Greater than 100 Lumens per watt light output in 3000k CCT, Housing shall be made of Pressure diecast Aluminium Housing and PC Cover to achieve IP66 with IK10 Protection. 10KV Surge Protection. 120-277V Voltage range, 325V High Cut off Protection and THD <10%. Fitting Diameter shall be 450mm, weight not less than 4kg and suitable for fixing upto 60mm dia pole of Philips BGP300 LED47 730 PSU PC SPD IN S1 or Techno Commercial equivalent in Keselec or Osram.
19
-
-
OD129528/2023-2024:Supply and installation testing and commissioning of 3.0 M height decorative pole with cast iron embellishments made of mild steel /steel tube complied with IS 1161/IS 3601, having thickness not less than 3mm. The bottom section having dia of 114mm with length of 1000mm along with inbuilt junction box, Upper section having dia of 76mm and length of 2000mm. The Pole has to be supplied with square shaped surface mounting base plate of min 200x200x12mm suitable for mounting on 4 nos of EN8 Grade foundation bolts of dimension M16x450mm. The pole shaft and base plate shall be hot dip galvanized (7stage process) as per IS 2629 having minimum average DFT of 65microns before the coating of epoxy primer. Complete pole shall be treated with high quality epoxy zinc rich penetrating primer (2 coats of primer) and thereafter coated with Polyurethane paint having minimum average DFT of 110 microns in antique gold and black finish of Kesslec ANTIQUE DECO POLE 3M PU or techno commercial equivalent in Philips or Osram.
19
-
-
OD131712/2023-2024:Supply, installation, testing and commissioning of Programming of Outdoor Façade Lighting Unistrip fitting in linear form factor with maximum power consumption of 35w DC and min 2300 Lumens system output in full load. Fixture shall be supplied with A4 optics with 25x40° degree to achieve required light spread. Fixture shall have minimum 24 nos of high power LED for proper light spread and Lifetime should be at least 50,000 burning hours at L70. The housing shall be made of Pressure diecast aluminium housing IP66 & IK08 protection, PMMA Lens and water proof vent valve. The fixture shall have IP67 Protected Loop-in and Loop-out cable with dedicated addressing wire & DC power cable for connection. Fixture dimention shall be not less than 1000mm length, 38mm width and 47mm height for fixing inside available space of Philips BCP382 36LED 30K 24V 17 L100 IN or Techno Commercial equivalent in Osram or Keselec.
20
-
-
Cabling
-
-
-
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
180
-
-
90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
365
-
-
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
300
-
-
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
30
-
-
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
30
-
-
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
22
-
-
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
24
-
-
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
12
-
-
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2
-
-
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
1400
-
-
90.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
300
-
-
90.16.2.5:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.50 mm dia. G.I. pipe (medium class)
20
-
-
OD131429/2023-2024:Supply & laying of one No. PVC insulated and PVC sheathed unarmoured copper cable of 1.1 KV grade of the following sizes in ground through DWC/HDPE as required. 3 core 1.5 sq mm
40
-
-
OD131430/2023-2024: Supply & laying of one No. PVC insulated and PVC sheathed unarmoured copper cable of 1.1 KV grade of the following sizes in ground through DWC/HDPE as required. 3 core 2.5 sq mm
870
-
-
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
150
-
-
OD134070/2023-2024:Supply and fixing of Cable Junction Boxes of size 104 x 104 x 70mm, IP 66 (Grey) with integrated membranes / metric knockouts for cable entry with terminals in surface/recess etc as required.
41
-
-
OD134071/2023-2024:Supply and fixing of Cable Junction Boxes of size 130 x 130 x 77mm, IP 66 (Grey) with integrated membranes / metric knockouts for cable entry with terminals in surface/recess etc as required.
61
-
-
DB & Accessories
-
-
-
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
1
-
-
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
5
-
-
90.11.1.15:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
50
-
-
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
6
-
-
OD131425/2023-2024:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
1
-
-
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
6
-
-
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
5
-
-
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
OD134081/2023-2024:Supply and installation of Three Phase Surge Protection Device as per EN 61643-11 / IEC 61643-11 suitable for protecting Class I + Class II Modular combined lightning current and surge arrester as TT and TN-S systems (3+1 configuration). Lightning impulse current upto 50KA and nominal discharge current 25/50KA with a respose time (tA) less than 100 ns. The Lightning impulse current shall be min 25 / 50kA suitable for mounting on 35mm Din rails. Easily replacable protection module having indication green to red of DEHNvap DVA CSP 3P 100 FM (900 360) or Techno- Commercially equivalent.
1
-
-
OD194953/2023-2024:Supplying and fixing 24Hours Digital Time Switch for operating ON-OFF function in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required. (L&T make Digital Time switch 2 module cat no 67DDT0 or Techno Commercial equivalent approved by engineer in charge)
1
-
-
OD194956/2023-2024:Supply and installation of C R C A sheet steel, minimum thickness 1mm phosphatised and powder coated, dust and vermin proof DP enclosure for independent mounting of MCB/RCCB/ISOLATOR including DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall,making good the damages ,colour washing etc as required.
1
-
-
High mast & Low Mast
-
-
-
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
4
-
-
90.15.2.4:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 150mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 6 nos fixed in existing RCC foundation and junction box etc, complete 16 Meters
1
-
-
90.15.2.5:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 150mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 6 nos fixed in existing RCC foundation and junction box etc, complete 20 Meters
1
-
-
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
16
-
-
90.15.4.9:Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
4
-
-
90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
6
-
-
OD134132/2023-2024:supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. (50/0.25mm) , 5 core 2.5 sqmm
40
-
-
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
10
-
-
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
15
-
-
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
15
-
-
OD134078/2023-2024:Steel reinforcement for RCC Work including straightening, cutting, bending, placing in position and binding all complete.
200
-
-
Earthing
-
-
-
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5
-
-
OD131415/2023-2024:Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
20
-
-
OD131416/2023-2024:Providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
1.25
-
-
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
1150
-
-
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
100
-
-
90.16.1.9:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.64 mm GI conductor (12 SWG)
40
-
-
90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
22
-
-
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
20
-
-
Panel Fabrication
-
-
-
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
8
-
-
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
10
-
-
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
50
-
-