IREL India Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

IREL India Limited Tender

Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date20 Feb 2024
Closing Date6 Mar 2024
Tender Amount₹ 67,80,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Annual Rate Contract (ARC) for repair and maintenance of electrical installations.
Annual Rate Contract (ARC) for repair and maintenance of electrical installations.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Installation and charging of new light points (include wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.). Details as per sl No 1.4 in BOQ

50

-

-

... More
Replacement of Street light fittings.Details as per sl No 1.5 in BOQ

200

-

-

... More
Installation and charging of new street light points (includes wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.).Details as per sl No 1.6 in BOQ

50

-

-

... More
Repair of light fittings (Tube light, HPMV, HPSV, CFL, LED, MH etc.). Details as per sl No 1.7 in BOQ

100

-

-

... More
Removal of Ceiling fan, wall mounting fans, pedestal fans etc. from its location, checking (replace if required) fan hooks, rubber bush, bolt& Nut etc. cleaning and refitting to its location.Details as per sl No 2.1 in BOQ

50

-

-

... More
Repair of Ceiling fan, wall mounting fans, pedestal fans.Details as per sl No 2.2 in BOQ

25

-

-

... More
Replacement of Ceiling fan, wall mounting fans, pedestal fans. Details as per sl No 2.3 in BOQ

100

-

-

... More
Installation and charging of new Ceiling fan/wall mounting fans/ pedestal fans etc. (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.4 in BOQ

25

-

-

... More
Repair of exhaust fans of different capacity. Details as per sl No 2.5 in BOQ

10

-

-

... More
Replacement of exhaust fans of different capacity.Details as per sl No 2.6 in BOQ

25

-

-

... More
Installation and charging of new exhaust fans of different capacity (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.7 in BOQ

50

-

-

... More
Repair of Tube axial fans/Air circulator/ Man cooler etc. Details as per sl No 2.8 in BOQ

25

-

-

... More
Replacement of Air circulator Man cooler etc. Details as per sl No 2.9 in BOQ

10

-

-

... More
Installation and charging of new Air circulator Man cooler (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.10 in BOQ

70

-

-

... More
Air Blowing, cleaning and servicing of PCC/MCC panels. While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). The work includes cleaning of the panels, checking the healthiness of panel feeders, Switch gears, Terminals, repair/replacement of the same in case damaged condition. Details as per sl No 3 in BOQ

100

-

-

... More
Air Blowing, cleaning and servicing of Main Switches, Starters, DBs’ While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). The work includes cleaning, checking the healthiness of feeders, Switch gears, Terminals, repair/replacement of the same in case damaged condition.Details as per sl No 4 in BOQ

50

-

-

... More
Replacement of contactors.Details as per sl No 5.1 in BOQ

25

-

-

... More
Replacement of over load relay. Details as per sl No 5.2 in BOQ

150

-

-

... More
Replacement of DOL starter. Details as per sl No 5.3 in BOQ

10

-

-

... More
Repair of DOL starter. Details as per sl No 5.4 in BOQ

10

-

-

... More
Installation and charging of DOL starter.Details as per sl No 5.5 in BOQ

25

-

-

... More
Replacement of contactors. Details as per sl No 6.1 in BOQ

10

-

-

... More
Replacement of over load relay. Details as per sl No 6.2 in BOQ

10

-

-

... More
Replacement of star delta timer. Details as per sl No 6.3 in BOQ

50

-

-

... More
Replacement of Star Delta Starter. Details as per sl No 6.4 in BOQ

25

-

-

... More
Repair of Star Delta starter. Details as per sl No 6.5 in BOQ

10

-

-

... More
Installation and charging of Star Delta starter. Details as per sl No 6.6 in BOQ

25

-

-

... More
Repair/replacement of remote switch station. Details as per sl No 7 in BOQ

150

-

-

... More
Installation and charging of remote switch station.Details as per sl No 8 in BOQ

25

-

-

... More
Repair/replacement of float switch control station. Details as per sl No 9 in BOQ

10

-

-

... More
Replacement of float switch. Details as per sl No 10 in BOQ

10

-

-

... More
Installation and charging of float switch control station & float switch (including its cabling). Details as per sl No 11 in BOQ

10

-

-

... More
Repair/replacement of Drives and its programming. Details as per sl No 12 in BOQ

15

-

-

... More
Repair/replacement of Lighting DBs. Details as per sl No 13 in BOQ

15

-

-

... More
Installation and charging of New Lighting DB (Includes cabling, termination, earthing etc. Details as per sl No 14 in BOQ

10

-

-

... More
Repair/replacement of Power DBs’. Details as per sl No 15 in BOQ

20

-

-

... More
Installation and charging of New Power DB (Includes cabling, termination, earthing etc. Details as per sl No 16 in BOQ

10

-

-

... More
32A to 160A. Details as per sl No 17.1 in BOQ

10

-

-

... More
200A to 400A. Details as per sl No 17.2 in BOQ

50

-

-

... More
Replacement of HRC Fuses. Details as per sl No 18 in BOQ

70

-

-

... More
Removal fuse/ isolation of power from electro-mechanical machinery for maintenance work. Details as per sl No 19 in BOQ

70

-

-

... More
Re-positioning fuse to circuit / charging the isolated power from the electro-mechanical machinery after maintenance work. Details as per sl No 20 in BOQ

70

-

-

... More
Installation/Replacement/Repair of MCB/MPCB. Details as per sl No 21 in BOQ

25

-

-

... More
32A to 160A. Details as per sl No 22.1 in BOQ

10

-

-

... More
200A to 400A.Details as per sl No 22.2 in BOQ

50

-

-

... More
630A and above. Details as per sl No 22.3 in BOQ

10

-

-

... More
0.5 HP to 7.5HP.Details as per sl No 23.1 in BOQ

500

-

-

... More
10HP to 30HP. Details as per sl No 23.2 in BOQ

200

-

-

... More
40Hp to 50HP. Details as per sl No 23.3 in BOQ

25

-

-

... More
0.5 HP to 7.5HP. Details as per sl No 24.1 in BOQ

10

-

-

... More
10HP to 30HP. Details as per sl No 24.2 in BOQ

50

-

-

... More
40Hp to 50HP. Details as per sl No 24.3 in BOQ

20

-

-

... More
0.5 HP to 7.5HP. Details as per sl No 25.1 in BOQ

300

-

-

... More
10HP to 30HP. Details as per sl No 25.2 in BOQ

25

-

-

... More
40Hp to 50HP.Details as per sl No 25.3 in BOQ

25

-

-

... More
0.5 HP to 7.5HP. Details as per Sl No 26.1 in BOQ

100

-

-

... More
10HP to 30HP.Details as per Sl No 26.2 in BOQ

25

-

-

... More
40Hp to 50HP.Details as per Sl No 26.3 in BOQ

25

-

-

... More
0.5 HP to 7.5HP. Details as per Sl No 27.1 in BOQ

25

-

-

... More
10HP to 30HP.Details as per Sl No 27.2 in BOQ

10

-

-

... More
40Hp to 50HP.Details as per Sl No 27.3 in BOQ

25

-

-

... More
Checking the conditions of heating coils & switch gears for the furnace/calciner. Details as per Sl No 28 in BOQ

30

-

-

... More
Cleaning, lubricating, and checking of hooks, clamps, Nuts& bolts, wire rope, chain and replacement (if required) of electric hoist. Details as per Sl No 29 in BOQ

50

-

-

... More
Repair the control circuit of the electric hoist. Details as per Sl No 30 in BOQ

10

-

-

... More
Removing of the unused/damaged cable, rolling out the cables, transport to salvage/scrap yard, after weighing, (with in 200mtr inside the company premises). Details as per Sl No 31 in BOQ

2

-

-

... More
Removing of the unused/damaged cable trays, light fixers, starter and frames, MS structural materials etc., transport to salvage/scrap yard, after weighing, (with in 200mtr inside the company premises). Details as per Sl No 32 in BOQ

2

-

-

... More
Disconnect incomer and outgoing power cable from the Old/damaged PCC/MCC/ MCB-DB panel, Removing the Old/damaged PCC/MCC/ MCB-Band Transport it to salvage/scrape yard after weighing (within 200mtr inside the company premises). Contractor shall remove the copper bus bar from the panel before shifting it to salvage/scrap yard, and handing over to electrical section. Details as per Sl No 33 in BOQ

2

-

-

... More
Installation and commissioning of PCC/MCC panes by connecting all the incoming, & outgoing cables including earthing of the panels. (Approximate size of the panels shall be 2500m x 1800mm x 400mm). Details as per Sl No 34 in BOQ

4

-

-

... More
Up to 6 ways. Details as per Sl No 35.1 in BOQ

5

-

-

... More
Up to 12 ways. Details as per Sl No 35.2 in BOQ

5

-

-

... More
Up to 24 ways. Details as per Sl No 35.3 in BOQ

3

-

-

... More
Fabrication, Painting, Installation of cable tray, cable tray support, street light supports, fixing frames for MCB-DB/starters/remote push station etc. (MS Structural material for the works shall be provided IREL, RED). Details as per Sl No 36 in BOQ

2

-

-

... More
Installation of FRP cable tray. (FRP cable tray for the works shall be provided IREL, RED). Details as per Sl No 37 in BOQ

500

-

-

... More
Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm Details as per Sl No 38.1 in BOQ

3000

-

-

... More
Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 38.2 in BOQ

3000

-

-

... More
Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 38.3 in BOQ

500

-

-

... More
Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 38.4 in BOQ

500

-

-

... More
Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 38.5 in BOQ

500

-

-

... More
Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 38.6 in BOQ

500

-

-

... More
Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 38.7 in BOQ

500

-

-

... More
Cable size (Al) 400Sq.mm. Details as per Sl No 38.8 in BOQ

500

-

-

... More
Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm. Details as per Sl No 39.1 in BOQ

500

-

-

... More
Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 39.2 in BOQ

100

-

-

... More
Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 39.3 in BOQ

50

-

-

... More
Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 39.4 in BOQ

30

-

-

... More
Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 39.5 in BOQ

20

-

-

... More
Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 39.6 in BOQ

20

-

-

... More
Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 39.7 in BOQ

10

-

-

... More
Cable size (Al) 400Sq.mm. Details as per Sl No 39.8 in BOQ

10

-

-

... More
Laying, dressing and termination of earth strip/earth wire to the earth points on panels, equipment, earth pits etc. as per the requirement. (Earth strip/earth wire and termination sockets shall be provided by IREL, RED on free of cost. Details as per Sl No 40 in BOQ

500

-

-

... More
Measuring, labelling and providing earth pit resistance report for all earth pits.Details as per Sl No 41 in BOQ

70

-

-

... More
Transformer Oil filtration and its associated oil checks (as per IS 1180:2014, IS 1866:2000, IS 1448:1997 with its amendments) and providing report for 500KVA, 11/0.415KV transformers. Details as per Sl No 42 in BOQ

5

-

-

... More
Additional charges for attending back shift breakdown work attending on emergency call basis per team of Supervisor and Electrician (This will be in addition to the respective charges for the work carried out.). Details as per Sl No 43 in BOQ

25

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.