INKEL Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

INKEL Limited - INKEL Tender

Works
Building Construction
Eprocure
Opening Date9 Jan 2025
Closing Soon10 Feb 2025
Tender Amount₹ 78,38,82,685 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 (Cement quantity -400kg/m3) of specified diameter and length below pile cap, to carry a safe working load not less than specified,excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation(DMC)or Bailer and chisel technique by Tripod and Mechanical Winch machine all complete,including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).900 mm dia piles

1675

-

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30(Cement quantity -400kg/m3) of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).1000 mm dia piles

825

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 200tonne and upto 230 tonne capacity.Initial test(for 800mm dia)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 200 tonne and upto 230 tonne capacity Routine test(For 800mm dia)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile upto 50 tonne capacityInitial test

1

-

-

... More
20.6.1.2 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile upto 50 tonne capacityRoutine test

1

-

-

... More
20.6.2.1 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityInitial test

1

-

-

... More
20.6.2.2 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 50 tonne and upto 100 tonne capacityRoutine test

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile of 262 tonne capacity Routine test.(Test Load 1.5 times the Safe Capacity)(for 900mm dia)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile of 262 tonne capacity Initial test.(Test Load 2.5 times the Safe Capacity)(for 900mm dia)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile 318 tonne capacity. Routine test (Test Load 1.5 times the Safe Capacity)(For 1000mm dia)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single pile 318 tonne capacity Initial test(Test Load 2.5 times the Safe Capacity)(For 1000mm dia)

1

-

-

... More
60.2.2 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump set including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete

80

-

-

... More
60.2.3 : Bailing out water using pump above 5 HP and Up to 10 HP-Bailing out water with engine and pump set above 5HP and up to 10HP, including conveyance to site and erection,cost of fuel, lubrication oil and other stores, pay of staff etc complete

35

-

-

... More
Sub Head- Earth Work

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

4665.11

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

1704.51

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

2086

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

3895.06

-

-

... More
Extra for conveying and depositing surplus earth beyond 50m and upto 1Km including loading and unloading as directed by Engineer- in-Charge.

2474.87

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

1495.34

-

-

... More
2.16.1 : Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m

463.92

-

-

... More
Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete ( Measurements to be taken of the face area timbered):Depth exceeding 1.5 m but not exceeding 3 m

1653.98

-

-

... More
2.18.3 : Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete ( Measurements to be taken of the face area timbered):Depth exceeding 3 m but not exceeding 4.5 m

710.59

-

-

... More
Sub Head -Plain cement Concrete

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

586.92

-

-

... More
Sub Head - Reinforced cement concrete and Shuttering work

-

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design) All work upto plinth level

56.12

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design) All work above plinth level upto floor V level

470.49

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 340 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design).All work upto plinth level

2182.96

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Min cement content is 340kg/cum and no payment shall be made for extra cement).All work above plinth level upto floor V level

4241.29

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Min cement content is 350kg/cum and no payment shall be made for extra cement).All work above plinth level upto floor V level

714.45

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:-Minimum Cement content is 360 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design.All work upto plinth level

85.19

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:-Minimum Cement content is 360 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design.All work above plinth level upto floor V level

745.37

-

-

... More
Providing and fixing at or near ground level precast cement concrete in slabs,kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)

3.66

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

2724.95

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

1721.41

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

8595.51

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

13250.67

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

19737.85

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

6518.87

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

644.01

-

-

... More
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards

47.26

-

-

... More
Extra for shuttering of circular column

169.56

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

764.5

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

12996.24

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

484041.9

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1205531.73

-

-

... More
Sub Head- Block Work

-

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

2575.77

-

-

... More
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

1419.23

-

-

... More
6.3.2 : Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With Modular bricks

87.05

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

275.17

-

-

... More
50.6.3.1 : Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth for 10 cm thick wall in CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete

27.14

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

89.85

-

-

... More
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete

207.3

-

-

... More
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

34.26

-

-

... More
50.6.2.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

345.85

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

1.51

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

74.32

-

-

... More
Sub Head - Joinery Works

-

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

1591.2

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

244.8

-

-

... More
Providing and supplying Single glazing of 6 mm thick monolithic toughened glass of approved colour and shade with SHGC=0.85 and VLT=36% etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass shall be measured in sqm

226.44

-

-

... More
Supply & Installation of Hindalco 85191 or equivalent louver section. The Fins should be fixed at 200mm module based on the requirement to the suitable Installation frame of aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings .The maximum length of the fin shall be determined based on the wind load calculation and deflection.Powder coated aluminium (minimum thickness of powder coating 50 micron)

361.82

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

5089.06

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

8079.83

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade II Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

499.5

-

-

... More
Providing and fixing pin headed glass in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): glass of 4.0 mm thickness

26.35

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness with U value=5.7,VLT=89% and SHGC=0.85.

328.5

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

158.57

-

-

... More
Providing and fixing anodised aluminium mesh ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the door shutter frame with C.P brass/stainless steel screws, including cutting the mesh to proper opening size and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of mesh to be measured for payment ).

97.2

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

192

-

-

... More
21.11.2 : Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm

68

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

157

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

956

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

330.9

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

93

-

-

... More
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm

349

-

-

... More
9.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm

349

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

74

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

155

-

-

... More
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

168

-

-

... More
9.106.2 : Providing and fixing PTMT handles with necessary screws etc. complete.150x34x24 mm weighing not less than 26 gms

190

-

-

... More
9.108.2 : Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms

380

-

-

... More
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

402

-

-

... More
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm

296

-

-

... More
Supplying and fixing 100mm mortice cylinder lock for aluminium door with following specification. a)Hook bolt has to be made of MS and SS for end plate and strike plate with lock set of size minimum 37mm, back set of min 20mm and hock bolt of min 18mm. b)Cylinder should be made of brass with minimum weight 0.20kg with nickel plated brass key(3 sets) and it should be of 5pin brass tumbler mechanism

246

-

-

... More
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) locking arrangement for sliding windows including necessary screws and fittings of approved make as directed by Engineer-in-charge.

391

-

-

... More
Providing and fixing roller for shutters of sliding aluminium windows with necessary screws etc.complete.As approved by Engineer-in-charge

1564

-

-

... More
Providing and fixing roller for Aluminium sliding door

12

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.1500mmX2400mm

3

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 1200mmX2100mm

1

-

-

... More
Providing and fixing of Single and double leaf Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1200mmX2400mm

9

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1500mmX2400mm

7

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.900mmX2100mm

4

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1800mmx2400mm

5

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1000mmX2100mm

16

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification for single leaf doors. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1200mmX2400mm

1

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.600mmX1500mm

26

-

-

... More
Frosted film - Supply and installation of 3M make frosted film pattern throughout all the internal glass panels wherever required of approx. 1.5 m height as per the approved pattern.

404.89

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

15.38

-

-

... More
9.5.1.2 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 30 mm thick shutters

440.88

-

-

... More
9.7.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Float glass panes4 mm thick glass pane

330.66

-

-

... More
50.9.15.2 : Supplying and fixing 300 mm Aluminium aldrop

190

-

-

... More
50.9.15.4 : Providing and fixing iron hooks and eyes: 150 mm

934

-

-

... More
9.14 : Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured)

440.88

-

-

... More
9.68.1 : Providing and fixing oxidised M.S. casement stays ( straight peg type) with necessary screws etc. complete.300 mm weighing not less than 200 gms

934

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item).With toughned glass of 6mm thickness.

78.03

-

-

... More
Providing and fixing glazing in aluminium door, window shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With toughned glass panes of 10 mm thickness with SHGC=0.85 and VLT=36%.

195.73

-

-

... More
Providing and fixing 1 mm thick M.S. sheet door with shutter frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings with outer frame of size 50x50x6 mm complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

11.76

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

676

-

-

... More
Sub Head - Steel work and Fire Doors

-

-

-

... More
21.17 : Providing and fixing anodised aluminium grill ( anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.(Only weight of grill to be measured for payment ).

2412.19

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

879.46

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

228.1

-

-

... More
13.48.2 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture

1591.57

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

22946.27

-

-

... More
10.25.1 :Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

829.2

-

-

... More
10.25.2 : Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

2139.6

-

-

... More
10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

103.68

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

20

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

86.4

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

17.28

-

-

... More
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 1200mmx2400mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors.

24

-

-

... More
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 1000mmx2100mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors

1

-

-

... More
Supply, installation, testing and commissioning of 600mmx1500mm duct door having 2hr fire rating with 46mm thick Shutter and outer frame of size 100x57mm. Shutter should be manufactured from 0.8mm thick GI sheet sandwiching with Honey comb insulation material. The door frames are manufactured from 1.2mm thick GI sheet. The door frame and single leaf door should be finished with powder coating of 50micron approved shade. Fire doors are inclusive of ball bearing SS hinges, mortice shaft lock and SS flush handle of size 120x40mm etc.as per the direction of Engineer -in charge.

15

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

5012.94

-

-

... More
16.70.2 : Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade

77.4

-

-

... More
Sub Head - Flooring and Waterproofing

-

-

-

... More
13.52.2 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work

1100.36

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

10908.53

-

-

... More
Providing and laying anti skid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm.

700.22

-

-

... More
11.48.2 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

700.22

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

151.93

-

-

... More
11.5 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

1100.36

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

8990.8

-

-

... More
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in dadoing over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), fixing with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

2413.88

-

-

... More
Providing and laying Vitrified step tiles in single piece indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.

281.47

-

-

... More
Extra for using or fixing glazed/ Ceramic/ Vitrified wall tiles with cement based high polymer modified quick-set tile adhesive ( Water based) conforming to IS : 15477, in average 3 mm thickness.

8990.8

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

1110.76

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

68.27

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

2499.23

-

-

... More
Providing and fixing machine cut, mirror/ eggshell polished , Flamed finished granite work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.18 mm thick granite stone slab of approved colour.

17.38

-

-

... More
Providing and fixing machine cut, mirror/ eggshell polished, Granite stone work for wall lining (veneer work) including dado, skirting, risers of steps, etc., in required design and pattern wherever require, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1cement : 3 coarse sand) laid and fixing with chemical adhesive,including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-charge.a. 18mm thick Granite of any colour and shade

245.28

-

-

... More
Grading roof for water proofing treatment with 12mm thick plastering in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and mixing with water proofing material in proportion recommended by the manufacturers

3124.84

-

-

... More
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

2651.78

-

-

... More
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

1657.53

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

1104.09

-

-

... More
Surface Preparation: Existing concrete surface shall be made clean,dry,smooth and free of chemical contaminants.The surface shall be thoroughly cleaned by using hand operated grinders for removing the laitence and exposing the porosity in the concrete surface. Down Take Pipe Packing: The pipes to be fixed should be filled in order to provided a proper bond and the same to be aligned by the respective agency.The annular space around the Rainwater pipe shall be packed using Conbextra GP2 or equivalent, a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR or equivalent on the core surface fixing leak free form work as per manufacturer's specification. Coving:Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with Nitobond SBR or equivalent at dosage of 2Ltrs per50kg cement as per manufacturer's specification. Pressure Grouting at Leaking points: Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex100@225gms or equivalent mixed to 50kg bag of cement including joints packing using polymer modified mortar. Fixing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification. Providing and applying a single component pitch free polyurethane based coating using Fosroc Nito proof 600 or equivalent that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane. It is elastomeric,seamless waterproof membrane applied in 2coats to DFT 1.2mm thick having a elongation capacity of over 400%. Termination to bed one on wall extending the coating to min. 300mm height above the finished floor level and sealed inside the groove of 20mm wide x 10mm thick flushed with polymer modified mortar as per vendor recmmendation. Laying 200gsm non woven geo textile membrane over waterproofing coating with overlap sealed using synthetic rubber adhesive before providing screed concrete. The material shall comply to ASTMC836. Elongation (ASTMD412):400%,Specific gravity:1.4g/cc, Solid content:85%, Modulus@100% elongation (ASTMD412):0.62N/mm², Tear resistance (ASTMD624):15N,Water vapour transmission (ASTME96):0.6g/m²/hr.,Water permeability@5bar: Nil, Shore A hardness (ASTM D2240) : 60.

3124.84

-

-

... More
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate

520.14

-

-

... More
Sub head - False ceiling works and Expansion Joint

-

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending

3784.47

-

-

... More
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm dip; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation

4794.5

-

-

... More
Aluminium Non perforated false ceiling - Providing & Fixing true horizontal level swing down suspended ceiling comprising of approved make Aluminum Clip in Swing Down with double pip self-leveling feature and special tabs to allow swing down of tile to enable plenum access with plain visual consisting of 600X600 mm clip in plain tiles of 0.7mm uniform thickness Aluminum with bevel edge in approved color precoated with primer coat at the rear side with Light Reflectance 60%.Tiles should have fire performance of Class A2-s1.d0 as per EN13501.The grade of aluminiumshall mandatorily be AA 3003. The AluminiumTile shall mandatorily be RoHS Compliant (Resistance of Hazardous Substance).Compliant certificate shall be provided on demand. The tile shall maintain uniform Thickness of 0.7mm across all areas of tiles with no deviation. The tile shall have paint thickness of 25 microns to enable better scratch resistance.The tile shall have the ability to combine the main light with extra illumination providing 77% light reflectance & enables to achieve light uniformity. The tile shall have g Ceiling Attenuation Class of 44db. It shall withstands upto 150 Scrub cycle using Scrubablity tester as per ASTM D 2486. The tile shall offer superior wash performance without compromising panel finish integrity using a washablity tester as per ASTM D 4828. Installation: To comprise 3000mm long ‘C’ channels spaced at 1200mm centers securely fixed to the structural soffit by support clamp & approved hangers. The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm spring tee bars shall be spaced at 600mm centers in a direction perpendicular to the C-channels and shall be secured at every intersection with C channel using a tee bar hanger. Use T bar connector to splice two pieces of spring tee bars. Tiles should be clipped in between two spring tee bars from below. This is a downward installation. All full panels can be removed and reinstalled without movement up into the plenum area. Perimeter trims of approved color secured to walls at 450mm maximum centers. Cut tiles to be secured to the wall angles using a spring clamp. The installation shall be undertaken as per the manufacturer’s installation instructions and as directed by the Engineer-in-Charge

1207.37

-

-

... More
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board

1334.73

-

-

... More
5.44.1 : Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self – centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge . (Material shall confirm to ASTM 6063).Floor Joint of 100 mm gap.

141.9

-

-

... More
5.45.1 : Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst thecomponents of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).Wall Joint of 100 mm gap.

218.4

-

-

... More
5.46.1 : Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In- Charge.The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s preengineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063.Roof Joint of 100 mm gap.

23.4

-

-

... More
od347931/2022_2023 : EXPANSION JOINT TREATMENT WORKS – INTERNAL WALL & CEILING:A)Providing, placing and fixing in position 100 mm wide expansion joint with PVC board of supreme make or Equivalent of 100 kg/cum density at all expansion joints and separation joints and wherever specified to the required sizes, shapes, etc., complete B)Protecting the expansion joint system with Aluminium sheet in a U shape fashion, extending the same up to 150 mm on both side vertically. (Both Horizontal & Vertical) Thickness of sheet is 2 mm.

115.6

-

-

... More
Sub Head - Finishes

-

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

3696.41

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

48893.95

-

-

... More
Wall painting with acrylic emulsion paint(low VOC paint as per Griha norms V-2015) of approved brand and manufacture to give an even shade:Two or more coats on new work

33663.73

-

-

... More
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).

9415.16

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc.Excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size).

58.89

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

41781.5

-

-

... More
13.5.1 : 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1 Cement : 4 coarse sand)

1204.04

-

-

... More
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

4799.15

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

28570.77

-

-

... More
Finishing walls with textured exterior paint (low VOC paint as per Griha norms V-2015) of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

1318.1

-

-

... More
Finishing walls with Acrylic Smooth exterior paint (low VOC paint as per Griha norms V-2015) of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

12599.19

-

-

... More
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

23.19

-

-

... More
Sub Head - Finishing and Roofing

-

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

43.74

-

-

... More
160mm uPVC for Rain Water Gutter with Leaf Guard - Supply, Installation, Testing and commissioning of 160mm uPVC Rain water gutter with Leaf Guard for Truss roof, including different types of fittings, required clamps and accessories. Gutters and fittings are specially designed to meet the requirements of all types of sloped roofs buildings. The system is provided with specially designed rubber gasket/seals to give totally leak proof joints to install with brackets and clamp complete.

379.4

-

-

... More
12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)

790.44

-

-

... More
12.49 : Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).

151.47

-

-

... More
Providing M.P tile pattern over sunshade with 20 mm thick plastering in 1:4 (1 cement : 4 fine sand) cement mix at all heights and levels, as per the direction & approval from engineer in charge.

678.25

-

-

... More
Providing valleys of 90 cm wide overall in plain 20 Guage Aluminium sheet fixed properly with neat finish complete as directed by Engineer in Charge

44

-

-

... More
Providing and fixing Anjili wood Eve boards of size 150 mm X 20 mm at the edges of rafter roof with necessary screws & per the existing design including charges for scafolding charges as directed by Engineer in Charge.

1004.09

-

-

... More
Sub Head - External Works

-

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

7

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

9

-

-

... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

3

-

-

... More
2.33.4 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth

2

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

500

-

-

... More
19.35.1 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.

80

-

-

... More
19.35.2 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.600 mm dia RCC pipes.

35

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

487.99

-

-

... More
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

2197.75

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

48.36

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

1041.3

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

40

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

30

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

50

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

10

-

-

... More
Site Clearance

-

-

-

... More
Clearing and grubbing land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and preservation of top organic soil not exceeding 200 mm in thickness In area of thorny jungle - By Mechanical Means

0.26

-

-

... More
Plumbing and Sanitary Works Sanitary Fixtures, Bath Fittings and Accessories

-

-

-

... More
Providing and fixing White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF (Adjusting up to 2/4 LPF) Dual Cistern, Overall size 660 x 375 x 760mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion / rawl sleeves,gasket etc. complete, and fixing to wall, as per manufacturer's instruction and to the approval of Engineer-in-charge. The Float Valve for Cistern shall be capable of withstand 5.0 Bar. Working Pressure

138

-

-

... More
Providing and fixing sanitary fixtures for handicapped toilet including one number White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF (Adjusting up to 2/4 LPF) Dual Cistern, overall size 660 x 375 x 760mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion / rawl sleeves, gasket etc. complete, wash basin, one pair mounting brackets, one number elbow operated pillar cock 3.8 LPM @ 3 Bar and all other related fittings like waste coupling one number hinged rail 76 cm & 4 nos. of grab rails 60cm etc., designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge.

6

-

-

... More
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

13

-

-

... More
17.80 : Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge.

30

-

-

... More
8.10.2 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade

23

-

-

... More
Providing and fixing White Vitreous China Counter Top / Bottom Wash Basin, 400 x 550 mm or equal, including 32mm. CP Waste Coupling, C.P. Brass Chain with rubber plug, and fixing to counter with suitable fixtures, all as per manufacturer's instruction and the direction of Engineer-in-charge.

74

-

-

... More
Providing and fixing White Vitreous China Wall Hung Wash basin, 550 x 400 mm or equal, including 32mm. CP Waste Coupling, C.P. Brass Chain with rubber plug, and fixing to wall with suitable fixtures, all as per manufacturer's instruction and the direction of Engineer-in-charge.

61

-

-

... More
Providing and fixing wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 400x400 mm

10

-

-

... More
Providing and fixing 15mm. CP Pillar Tap, Self Closing Type with Pre Set time 5 to 15 Sec, with a controlled flow rate of 3.8 LPM at 3 Bar. complete with all necessary accessories for Domestic Wash Basins, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

145

-

-

... More
17.25.6 : Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:Surgeon type wash basin of 660x460 mm

5

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action Pillar Tap with extended lever handle, flow rate of 3.8 LPM at 3 Bar, complete with all necessary accessories for Wash Basins all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

5

-

-

... More
Providing and fixing of Black colour Poly Propylene Laboratory Sink, Dimensions: external 558 x 355 x 240mm, Net weight: 2.7 kg, Temperature range: 0-80°C, 1/2” BSP Waste connection, Net weight: 0.2 kg Dimensions: Ø73, 1½” BSP with PTMT/PP waste coupling, adjustable screw on nut. , including cutting and making good the walls wherever required: Polypropylene Laboratory Sink without drain board

17

-

-

... More
17.10.1.3 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 200 mm

2

-

-

... More
17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm

7

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action, Wall Mounted type, Sink Tap with extended lever handle, flow rate of 3.8 LPM @ 3 Bar, complete with Wall Flange and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

9

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action, Wall Mounted type, Clinical Sink Mixer with extended lever handle, flow rate of 3.8 LPM @ 3 Bar, complete with Wall Flanges and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

17

-

-

... More
Providing and fixing CP Shower Set, for Cold Water only, low flow rate of 6 LPM or less, Commercial Range, complete with Concealed Valve & Exposed Control Unit, Head Shower, Shower Arm, etc., including all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

82

-

-

... More
Providing and fixing CP Long Body Tap, both Cold & Hot Water Supply, with a controlled flow rate of 6 LPM @ 3 Bar, 15mm. nominal bore, 185mm. long with wall flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

142

-

-

... More
Providing and fixing Health Faucet with a controlled flow rate of 3.8 LPM @ 3Bar, 15mm. CP Braided Hose, Hook and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

144

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

469

-

-

... More
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore

325

-

-

... More
Providing and Fixing ABS Body P-Trap with threaded union connections, flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge. For Wash Basin, 32mm, Size.

156

-

-

... More
Providing and Fixing ABS Body P-Trap with threaded union connections, flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.For Sinks and Scrub, 40mm, Size

26

-

-

... More
Providing and fixing at site in position Grab Bar up to 600mm complete.

151

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

82

-

-

... More
17.72 : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms

31

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

82

-

-

... More
17.34.1 : Providing and fixing toilet paper holder:C.P. brass

4

-

-

... More
Providing and fixing of C. P. Robe Hook, 60mm. Dia. x 45mm. High.

157

-

-

... More
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

5

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

150

-

-

... More
Providing and fixing cooler (hot, cold and normal water) with inbuild RO filter including cost and conveyance of all materials labour charges etc. complete, including necessary wall cutting / chasing and making good as required etc. complete, testing and commissioning to the satisfaction of Engineer in Charge as per direction of Engineer-In charge at all levels.

4

-

-

... More
Providing and fixing of Slop Hopper with Pressing valve 304G Stainless Steel, Conical flushing bowl with continues flushing rim having whirl effect, P / S trap for drainage, Health faucet Dimension : 24”L x 24”W x 35”H"

8

-

-

... More
INTERNAL DRAINAGE

-

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).160mm OD

75

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y,couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners (8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).110mm OD

755

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).75mm OD

920

-

-

... More
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall

450

-

-

... More
50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall

160

-

-

... More
50.18.9.14.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall

358

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

225

-

-

... More
50.18.8.5.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2

144

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type A (IS:13592)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y,couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site(For Vent pipes -Internal).75mm OD

49

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of 4kg/cm2 (IS:4985)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends,Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Vent pipes -Internal).63mm OD

479

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. ""U"" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 160mm OD"

25.2

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately.Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails (2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.110mm OD

487.2

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).Core Cutting in RCC Structure shall measured separately.Clamping details - For Vertical Shafts .G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.75mm OD

243.6

-

-

... More
"Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts.G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails (2.5 mm thick) or Clamping with Universal clamps, Anchor fastners (10mm),Threaded Rod(10mm), nuts, washers etc complete.160mm OD"

714

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete.110mm OD

210

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I."U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated, Clamping details - For Suspended lines G.I."U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps,Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 75mm OD

268.8

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe of 4kg/cm2 (IS:4985))including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners (10mm), Threaded Rod (10mm), nuts, washers etc complete. 63 mm OD (4kg/cm2)

37.8

-

-

... More
Deep Seal uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position Deep Seal (7”) uPVC Fabricated Multi Floor Trap, with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, Anchor fasteners etc. complete in all respects - 50/75 mm dia inlet/outlet (In Ceiling)

243

-

-

... More
uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost o cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken)

42

-

-

... More
Supplying, installing, testing & commissioning at site in position 110mm dia deep seal PVC P Trap with boss tee and access cap including all necessary fittings and supports complete.

22

-

-

... More
Providing and Fixing C.P. brass or stainless steel(SS-304) Square Flat cut single piece Gratings size 125x125 mm. Gratings for 110mm. Floor Traps.

285

-

-

... More
Heavyduty stainless steel cover for Concealed Floor Trap for Urinal - Providing and Fixing 125x125mm dia Heavyduty stainless steel cover for Concealed Floor Trap ISI 304 Cover, for Urinal.

27

-

-

... More
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 110mm

12

-

-

... More
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 75mm

12

-

-

... More
17.35.1.3 : Providing and fixing soil, waste and vent pipes:100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

83.6

-

-

... More
17.38.1.3 : Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm diaHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

14

-

-

... More
17.39.1.3 : Providing and fixing plain bend of required degree.100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

5

-

-

... More
17.42.1.3 : Providing and fixing double equal plain junction of required degree.100x100x100x100 mmHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

1

-

-

... More
17.44.1.3 : Providing and fixing single equal plain junction of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

2

-

-

... More
17.49.1.3 : Providing and fixing double equal plain invert branch of required degree:100x100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

1

-

-

... More
17.50.1.3 : Providing and fixing single equal plain invert branch of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

2

-

-

... More
17.56.1.3 : Providing and fixing terminal guard:100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

1

-

-

... More
17.60.1.3 : Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outletHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

10

-

-

... More
17.57A.1.1 : Providing and fixing shielded coupling for Hubless centrifugally cast iron pipeSS 304 grade coupling with EPDM rubber gasket

40

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Dome Type with Cast Iron body, Aluminium Ring, Aluminium Dome, S.S. Screws etc. complete with Gratings, suitable for 160mm. of down pipes. 150mm dia. for 160mm. PVC Down Pipe

4

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Dome Type with Cast Iron body, Aluminium Ring, Aluminium Dome, S.S. Screws etc. complete with Gratings, suitable for 110mm. of down pipes. 100mm dia. for 110mm. PVC Down Pipe.

4

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Side Wall Parapet Type in Cast Iron body, Aluminium Gratings, S.S. Screws etc. complete with Gratings, all as per Technical Specifications.100mm dia. for 110mm. PVC Down Pipe

4

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Side Wall Parapet Type in Cast Iron body, Aluminium Gratings, S.S. Screws etc. complete with Gratings, all as per Technical Specifications.150mm dia. for 160mm. PVC Down Pipe

4

-

-

... More
WATER SUPPLY

-

-

-

... More
18.8.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes

186

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

1860

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

88.8

-

-

... More
18.7.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15 mm nominal outer dia pipes

740

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

2282.8

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

378.8

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

180.4

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

269

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

254.2

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft-65 mm nominal outer dia. Pipes.

28.4

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work -Exposed on wall - Ceiling and Shaft-20 mm nominal outer dia. Pipes.

37.8

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing, Anchor fastners (8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work -Exposed on wall - Ceiling and Shaft-25 mm nominal outer dia. Pipes

37.8

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft-32 mm nominal outer dia. Pipes.

119.8

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft-40 mm nominal outer dia. Pipes.

127.2

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 50 mm nominal outer dia. Pipes.

377

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes.

564.2

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft -80 mm nominal outer dia. Pipes.

230

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 100 mm nominal outer dia. Pipes.

233.6

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft-150 mm nominal outer dia. Pipes.

55

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 100 mm nominal outer dia. Pipes.

77.8

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 80 mm nominal outer dia. Pipes.

77.8

-

-

... More
18.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

298

-

-

... More
18.18.3 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore

12

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

20

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

15

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

9

-

-

... More
Supply, fix at site in position, test and commission, Brass Ball Valves to IS: 554 / BS:21 / ISO: 7, PN;25,with Screwed Female Ends complete with all necessary accessories. 40mm. (11/2")

5

-

-

... More
Supply, fix at site in position, test and commission, Brass Ball Valves to IS: 554 / BS:21 / ISO: 7, PN;25, with Screwed Female Ends complete with all necessary accessories.50mm. (2")

4

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories.&15mm. (1/2")

43

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories.20mm. (3/4")

43

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories. 25mm. (1")

8

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN;20, Screwed Female ends, complete with all necessary accessories.32mm. (11/4")

9

-

-

... More
18.19.4.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreVertical

1

-

-

... More
18.19.6.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreVertical

2

-

-

... More
Providing and fixing Brass non-return valve of approved quality (screwed end):100 mm nominal bore Vertical.

2

-

-

... More
Brass Automatic Air Release Valves - Providing, Fixing, testing and commissioning at site in positions Brass Automatic Air Release Valves, of approved quality and make on the top of the vertical water supply pipes as per specification and drawing - 3/4"(20mm) dia

40

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN10) of approved make with PP float & nipple with brass threaded in-sert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 65mm dia (2 1/2")

1

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN10) of approved make with PP float & nipple with brass threaded in-sert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 50mm dia (2")

1

-

-

... More
SS ball valve 50mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 2"(50mm) dia

5

-

-

... More
SS ball valve 40mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1½”(40mm) dia

2

-

-

... More
SS ball valve 32mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1¼”(32mm) dia

4

-

-

... More
SS ball valve 25mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1” (25mm) dia

1

-

-

... More
SS ball valve 20mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - ¾” (20mm) dia

14

-

-

... More
SS ball valve 15mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - ½” (15mm) dia

8

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

3

-

-

... More
Providing and fixing C.I. Sluice Valve, PN-10, with IS: 14846 Mark, with required flanges, rubber in sertions, bolts, nuts, Washers etc. complete.300mm PN-10

2

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect.80 mm dia

2

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect.100 mm dia

2

-

-

... More
Supplying, fixing testing and commissioning Stainless steel Butterfly Valve Grade 316(CF8M), PN-16,Wafer type, Lever Operated, Confirming to BIS: 5155 / IS 13095 / API 609, with required flanges, nuts,bolts etc., complete 65 mm dia

1

-

-

... More
CI Y Strainer 1 ½” (40mm) dia -Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
CI Y Strainer 2” (50mm) dia - Supply, Installation, Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects

3

-

-

... More
CI Y Strainer 2 ½” (65mm) dia -Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
CI Y Strainer 3” (80mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
CI Y Strainer 4” (100mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
CI Y Strainer 6” (150mm) dia -Supply,Installation,Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects

2

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 20 mm. dia. (3/4") pipe.

4.2

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 25 mm. dia. (1") pipe

4.2

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 32 mm. dia. (1 1/4") pipe.

12.6

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 40 mm. dia. (1 1/2") pipe.

30

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 50 mm. dia. (2") pipe.

120

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 65 mm. dia. (2 1/2") pipe.

170

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 80 mm. dia. (3") pipe.

115

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 100 mm. dia. (4") pipe.

95

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 15mm. (1/2") pipe.

185

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 20mm. (3/4") pipe.

570.7

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 25mm. (1") pipe.

94.7

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 32mm. (1 1/4") pipe.

180.4

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 40mm. (1 1/2") pipe.

269

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 50mm. (2") pipe.

254.2

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 65mm. (2 1/2") pipe.

28.4

-

-

... More
EXTERNAL SEWERAGE AND STORM WATER DRAIN

-

-

-

... More
"Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation) 200mm OD.

300

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients,PVC pipe of IS 4985(6kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation) 160mm OD.

600

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete (excluding excavation)110mm OD.

100

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation)75mm OD.

50

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation)315mm OD

100

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation)250mm OD.

100

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation)200mm OD.

100

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation).160mm OD

50

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation).110mm OD

50

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, this includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation)65 mm nominal outer dia Pipes.

120

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work (Including excavation)80 mm nominal outer dia Pipes.

120

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, this includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation)100 mm nominal outer dia Pipes

20

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation)65 mm nominal outer dia Pipes

100

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, this includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation)80 mm nominal outer dia Pipes.

100

-

-

... More
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 90 mm dia 10 kgf/cm2

500

-

-

... More
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With Sewer bricks conforming to IS: 4885

30

-

-

... More
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design

400

-

-

... More
Extra for excavating trenches for pipes above 80mm. But not exceeding 300mm. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre).Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

50

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

1400

-

-

... More
18.41.1A : Providing and filling sand of grading zone V or coarser grade, all - round the G.I. pipes in external workSub analysis item for sand filling component

56

-

-

... More
4.1.10 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

168

-

-

... More
Supply, installation, testing and commissioning at site Rain Water Filter Unit, Bag Filtration System, suitable for a Flow Rate of 135M³/ Hr, with Filter Bags and Accessories in FRP Fabricated Tank, 1500mm. dia. x 1500mm.deep. Wall thickness 10mm. all as per Technical Specifications. The price is inclusive of connected Pipe Work. Civil work is to be counted separately.

1

-

-

... More
CIVIL WORK FOR RCC MANHOLE

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

258.04

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

162.16

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

3.04

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

19.05

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

90.82

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

190.5

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

701.3

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

190.5

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

11296

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

4445.5

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

701.3

-

-

... More
Providing and fixing at or near ground level precast cement concrete in slabs,kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)

20.21

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - For 160mm dia. pipe

10

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 110mm dia pipe

505

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 75mm dia pipe

3

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 63mm dia pipe

34

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 50mm dia pipe

247

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 40mm dia. pipe

23

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 32mm dia pipe

179

-

-

... More
Supplying, Installation, Testing and Commissioning of the Ductile Iron Circular Manhole cover with Frame (Double seal with EPDM Gasket and SS Bolting arrangement lifting key holes & load tested as per IS:1726 & BS EN:124.600mm Dia. (Medium duty) (Minimum weight 68Kg).

6

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 40mm dia. pipe

3

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 100mm (4")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 100mm(4") uPVC Astm Sch 80 Puddle flange

15

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 80mm (3')uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 80mm(3") uPVC Astm Sch 80 Puddle flange.

6

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 65mm (2½") uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -65mm (2½") uPVC Astm Sch 80 Puddle flange

14

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 50mm (2")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 50mm(2") uPVC Astm Sch 80 Puddle flange

6

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 40mm (1½")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -40mm (1½")uPVC Astm Sch 80 Puddle flange

1

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 32mm (1¼")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -32mm 1¼"uPVC Astm Sch 80 Puddle flange

1

-

-

... More
PLUMBING PUMPS AND HEAT PUMPS

-

-

-

... More
Supply, Installation, Testing and Commissioning 2 nos, Vertical Multistage Pump Set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 12.00lps @ 45mtr head, Head range 35 to 55 mtrs, ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection with Wall mounting Microprocessor based common control Panel to operate the pump set as ( 1Working +1Standby ) Star Delta, having features of automatic pump change over in every Start/Stop, Dry run,Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function with sufficient length cable, Digital display, Pressure gauge - 2nos, Float Switches, Auto/Manuel Operation.

1

-

-

... More
Supply, Installation, Testing and Commissioning 2 nos, Vertical Multistage Pump Set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 7.00lps @ 45mtr head, Head range 35 to 55 mtrs, ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection with Wall mounting Microprocessor based common control Panel to operate the pump set as ( 1Working +1Standby ) Star Delta, having features of automatic pump change over in every Start/Stop, Dry run,Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function with sufficient length cable, Digital display, Pressure gauge - 2nos, Float Switches, Auto/Manuel Operation.

1

-

-

... More
SEWAGE & WASTE WATER CUTTER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Cutter Pumps with High Efficiency Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete as per Tender Drawings and Tender / Technical Specifications Cable length all Cutter Pumps shall be 10Mtr.Minimum Capacity : 4LPS @ 15 Mtr. Head, 3Ph, Complete Set."

2

-

-

... More
SEWAGE & WASTE WATER CUTTER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Cutter Pumps with High Efficiency Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete as per Tender Drawings and Tender / Technical Specifications Cable length all Cutter Pumps shall be 10 Mtr. Minimum Capacity: 3LPS @ 15 Mtr. Head, 3Ph, Complete Set

4

-

-

... More
SEWAGE & WASTE WATER CUTTER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Cutter Pumps with High Efficiency Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete as per Tender Drawings and Tender / Technical Specifications Cable length all Cutter Pumps shall be 10 Mtr.Minimum Capacity: 2LPS @ 15 Mtr. Head, 3Ph, Complete Set.

4

-

-

... More
FILTER FEED PUMP SET-:Supply, Testing and Commission Filter Feed Pump Set, Submersible Type for Pumping Raw Water to Water Treatment Plant, 2 Pump System with One Working + 1 One Cyclically Stand by Pumps, each Pump of Capacity: 25M³/Hr. @ 15Mtr. Head, Head range 3 to 18.8 mtr, having CI Casing, SS Shafts, CF8 Impeller with 3Ph, complete with Microprocessor Based Control Panel, for Auto and Cyclic Operation, with all Protection (Digital display, Low &high voltage protection, dry run, phase reversal, pump over load, etc.), Level Sensors / Float Switches in Treated Water & Raw Water Tanks and Control Cabling / Wiring between Level Sensors / Float Switches and Control Panel, Delivery Manifold,Isolating Valves, Non Return valves, Pressure Gauge, Fittings, Stainless Steel (Grade:304) Lifting Chains, Accessories etc. all as per Technical Specifications. The Control Panel shall be capable operating the pumps (starts and stops) by sensing the level difference in water in the Treated Water Tank. Also; capable of ‘not starting or stopping the running pumps', when the water in the underground Raw Water Tank goes below the pre-set minimum level. The Pumps to be installed in the Underground Raw Water Tank and Common Control Panel in the Pump Room, in Basement Floor, approx. 50 Mtr. away from Raw Water Tank. The Underground Power Cabling between Pumps and Control Panel and Control Cabling between Control Panel & Level Sensor / Float Switch, in the Underground Raw Water Tank, shall be measured as a part of Electrical Work. The Quoted Price for the Pump Set shall be inclusive of all above requirement, necessary Level Sensors / Float Switches, Power Cabling, Control Cabling etc, except what measured as a part of Electrical Work, as detailed above.

1

-

-

... More
Supply, installation, testing & commissioning of Solar assisted Heat pump, insulated pressurised SS storage tank, hot water expansion vessel, insulated piping between the system, valves & accessories required to complete the system in position with the following specification.10,000 LPD, consisting of Solar Hot Water Panels of Aggregate Capacity: 5,000 LPD (50% of the total requirement), 58 Deg C required Insulated Hot Water Storage Tank suitable for 6 bar pressure SS 316 - 1no, 5000 Litre -Horizontal. COP of Heat pump 4.Circulation Pump between heat pump and storage tank, including control panel. Plumbing work Between storage tank and heat pump CPVC Pipe with suitable CPVC Fittings. Suitable Brass Fittings like NRV, Y Strainer, Air Vent, MTA, FTA, Flow Switches, Pipeline Insulation.The price inclusive of all electrical work from Pump panel to Heat Pump , cabling, PVCconduits, contractors, suitable fittings, all accessories etc.in complete

1

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

-

-

... More
WATER TREATMENT PLANT AND PUMPS

-

-

-

... More
Supply, Installation, testing and commission Water Pre-Treatment Plant Capacity: 25M3 /Hr, for continuous operation of 10 Hr, complete with High Pressure Sand Filter, Activated Carbon Filter,with Multiport valves, Chemical Dosing etc as per final requirement, connected Pipe Work etc, all as per Technical Specifications.Filter Feed Pumps shall be measured seperately.

1

-

-

... More
Providing, Fixing, Testing and Commission Submersible Type De-watering Pump Set, complete set with 1 working Submersible non- clog pump, Solids handling: 10mm, and with Common Control Panel for auto and cyclic operation. Capacity 3.5lps at 13.5Mtrs. head each, Head range 5 to 17 mtr, Three Phase, with float switches/level sensors etc. necessary control valves, fittings and accessories, for discharging rain water from collection pits in basement floor, to lower strata. The price shall inclusive of all connected electrical work as detailed in the technical specification.Impeller - Cast Iron FG 260,Cast Iron - S.S AISI 410

1

-

-

... More
Providing, Fixing, Testing and Commission Pressure Booster for Water Distribution System with Factory Assembled Packaged Pump Set, complete with 3 Vertical Multistage Inline / Horizontal End Suction Pumps (as per Manufacturer), with S.S Impeller and S.S Shafts, One Working, One Assist and 1 Stand by Pumps, each of Capacity: 2 M3 / Hr @ 15 Mtr. Head, each, IE3 Rated Electric Motors, complete with VFD Drive, Automatic Microprocessor Based Control Panel, Pressure Transducer Sensors, Pressure Gauges, 100Ltr. Diaphragm Pressure Vessel, Individual Suction Lines, Common Delivery Manifolds, Isolating Valves, Non Return Valves, Fittings, Accessories etc, all a on common frame. etc, all a on common frame. The Quoted Price for the Pump Set shall be inclusive of connected Electrical Work, all as per Technical Specifications.

1

-

-

... More
od171727/2023_2024 : "Supplying, Installing, Testing & Commissioning at site hot water recirculation pump with suitable pressure switch, dry run protection & The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication(Modbus). Type : Thermostatic Controlled. Horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The shaft, impellers and chambers are made of stainless steel. The inlet and discharge parts are made of cast iron. It’s supporting up to 95 degree Celsius temperature, digital control panel with Time and Temperature settings facility.<br>Flow for each pump in LPS : 2.3<br>Head in mtr : 14<br>Head Range : 8 - 16 mtr<br>MOC : SS 304 Impeller<br>Total no of pump: 1 SET ( 1Working + 1Standby )

1

-

-

... More
SEWAGE TREATMENT PLANT - 300 KLD

-

-

-

... More
Supply, installation, testing, commissioning and operation of Sewage Treatment Plant Electro - Mechanical Work, Capacity: 300KLD, as per KSPCB norms all as per the detailed specification, Civil work is to be counted separately.

1

-

-

... More
Operation and maintenance of the 300 KLD STP and 25m3/hr WTP for one year. (Consumables are the client scope).

1

-

-

... More
VALVES (E AND M)

-

-

-

... More
16.11.1.2 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) of 150 mm dia

5

-

-

... More
16.11.1.4 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 100 mm dia

12

-

-

... More
16.11.1.5 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 80 mm dia

4

-

-

... More
16.11.1.6 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 65 mm dia

13

-

-

... More
Electrical Works Wiring and Accessories

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

1478

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

1170

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

192

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

261

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

192

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

261

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

10080

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

15840

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

6728

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

400

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

500

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

100

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

50

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

150

-

-

... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

23

-

-

... More
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

215

-

-

... More
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

172

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in reces including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

221

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

228

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

900

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

150

-

-

... More
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

68

-

-

... More
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required

140

-

-

... More
15.4.3 : Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required3 output (1output per phase) and suitable for three phase supply

1

-

-

... More
CABLE TRAY

-

-

-

... More
4.1.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

207

-

-

... More
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

80

-

-

... More
4.1.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness

60

-

-

... More
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

212

-

-

... More
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

525

-

-

... More
4.1.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

100

-

-

... More
4.2.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required600 mm width X 50 mm depth X 2.0 mm thickness

6

-

-

... More
4.2.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required300 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
4.2.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required225 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.2.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required450 mm width X 50 mm depth X 2.0 mm thickness

3

-

-

... More
4.2.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required150 mm width X 50 mm depth X 1.6 mm thickness

32

-

-

... More
4.2.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required100 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
4.3.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

18

-

-

... More
4.3.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.200 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.3.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

3

-

-

... More
4.3.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
4.3.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.3.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
4.4.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

10

-

-

... More
4.4.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.4.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

3

-

-

... More
4.4.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
4.4.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
4.4.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
4.5.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

5

-

-

... More
4.5.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
4.5.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

2

-

-

... More
4.5.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

18

-

-

... More
4.5.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
4.5.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
HT PART

-

-

-

... More
Supply of following 11kV grade XLPE insulated PVC sheathed wire armored aluminum conductor power cable suitable for 11kV earthed system conforming to IS 7098(Part 2) and other relevant standards.(Refer detailed technical specification) 3 Core 300 Sq.mm 11kV(E)

200

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

160

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

20

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

20

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

3

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

10

-

-

... More
11KV INDOOR TYPE PACKAGE SUBSTATION

-

-

-

... More
11 KV PACKAGE SUBSTATION Supply, receiving, storing, inspection, handling, assembling, installation in correct aligned position, effecting proper connections, testing and commissioning of Indoor package type substation with 2 Nos.500 KVA,11/0.433 kV Dry type transformer, 4 mm thick base frame and 2 mm thick wall of each compartment naturally cooled type, as per the following specifications. A. 11KV HT VCB PANEL; Incoming a) VCB 11kV 630A 3P 350 MVA - 1 no with 24V DC trip, built in power pack with battery backup, charger b) Numerical relay (51) - 2 Nos c)Numerical relay (51N) - 1 No d) CR CT 60/5A 10VA CL:5P10 - 1 Set f) Annunciation Relay (30) -1 No. with indicator g) Hooter - 1 No. h) Lamps for Breaker ON, OFF, TRIP, Spring charged; Trip Circuit Healthy i) 230V Spring Charged Motor, push Button for ON, OFF, TCH - 1 Set j) PT - 11KV/110V 3 Phase 100VA CL-0.5 for incomer panel with three phase digital voltmeter -1 set k) Termination - suitable for 3c 300sqmm XLPE cable l). Phase Indication Lamps with protection fuses or MCB s HT Busbar: 630A 350MVA TP +Earth Outgoing- VCB 11kV 630A 3P 350 MVA – 3 nos each consists of 24V DC built in power pack with battery backup, charger Numerical relay (50) (51) - 2 Set Numerical relay (50) (50N) - 1 Set CR CT 60/5A 10VA CL:5P10 1 Set, CR CT 60/5A 10VA CL:1 - 1 Set ; Hooter - 1 No. Three phase digital ammeter (0-75A) - 1 Set. Annunciation Relay (30) - 1 No. with 8 Window Annunciator. Auxiliary relays for T/F Temperature alarm and trip Master trip relay (86) - 1 Set Termination -direct busbar connection to transformer primary. Indication lamps for Breaker ON, OFF, TRIP, Spring charged and Trip Circuit Healthy, 230V Spring Charger Motor, Push button for ON, OFF ; TCH- 1Sets. Transformer: 2nos 500 kVA,11kV/433V, 3 phase, Copper Winding, Air Natural Cooling, DYN-11 Indoor Dry Type Transformer, with OLTC Tapping from +5% to -15% in steps of 1.25%, with vaccum type OLTC with RTCC and incoming & outgoing cable boxes suitable for 3core x 300sq.mm 11kV XLPE cable and L.V side suitable for 3 x 3.5corex400sq.mm 11kV XLPE cable as per IS 2026/IS 11171 with latest amendment up to date. Transformer losses shall be as per ECBC guidelines amended up to date. Neutral CT of ratio 140/5A, class 5P10 15VA of accuracy for earth fault relay in a metallic enclosure including control wiring from the transformer.

1

-

-

... More
DIESEL GENERATOR

-

-

-

... More
500KVA DG Set:- Supply, Installation, Testing and Commissioning of 500 kVA prime rated DG set with acoustic enclosure, DG control panel, protection and digital metering, controls and interlocks, CT's and transducers for all metering and protection with suitable size breaker, suitable for AMF operation and synchronization, antivibration mountings, exhaust silencer etc. conforming to latest environment protection regulations for emission and noise levels water/coolant cooled, (radiator type) four stroke,electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz,3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand,auto charge, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation,fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications. The work should be as per MOEF standards and comply to latest CPCB IV plus norms.(Civil works excluded).

1

-

-

... More
320KVA DG Set:- Supply, Installation, Testing and Commissioning of 320 kVA prime rated DG set with acoustic enclosure, DG control panel, protection and digital metering, controls and interlocks, CT's and transducers for all metering and protection with suitable size breaker, suitable for AMF operation and synchronization, antivibration mountings, exhaust silencer etc. conforming to latest environment protection regulations for emission and noise levels water/coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz,3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand,auto charge, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications. The work should be as per MOEF standards and comply to latest CPCB IV plus norms.(Civil works excluded).

1

-

-

... More
200KVA DG Set:- Supply, Installation, Testing and Commissioning of 200 kVA prime rated DG set with acoustic enclosure, DG control panel, protection and digital metering, controls and interlocks, CT's and transducers for all metering and protection with suitable size breaker, suitable for AMF operation and synchronization, antivibration mountings, exhaust silencer etc. conforming to latest environment protection regulations for emission and noise levels water/coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz,3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, auto charge, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications. The work should be as per MOEF standards and comply to latest CPCB IV plus norms.(Civil works excluded).

1

-

-

... More
EXHAUST PIPES;Supplying and fixing exhaust gas piping of suitable dia, welded black M.S, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust.- 10 inch dia Exhaust pipe

64

-

-

... More
EXHAUST PIPES:Supplying and fixing exhaust gas piping of suitable dia, welded black M.S, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust. 8 inch dia Exhaust pipe

70

-

-

... More
EXHAUST PIPES:Supplying and fixing exhaust gas piping of suitable dia, welded black M.S, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust.- 6 inch dia Exhaust pipe

66

-

-

... More
EXHAUST PIPES:Supplying and fixing exhaust gas piping of suitable dia, welded black M.S, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust. 4 inch dia Exhaust pipe

68

-

-

... More
PANEL BOARDS,ENCLOSURES AND ACCESSORIES

-

-

-

... More
Main Panel:-Supply, Installation, Testing and Commissioning of 415 V 50Hz LT Switch board OEM Design Verified Assembly Panel complying to IEC 61439 Part 1 & 2.The Enclosure shall be selfsupported, free standing powder coated compartmentalized cubicle type , Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition),cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned.Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- (KSEB Side) a) 2 Nos 800 A 50 kA 4P ACB EDO μP based with 3O/C 1E/Releases & S/T O/V relay with CT at neutral earthing conductor b) 2 Set RYB Indication Lamp c) 2 Nos (0-800)A three phase digital ammeter d) 2 Nos (0-500)V three phase digital Voltmeter e) 2 Nos of 51G relay f)2 Nos. of Multifunction Digital meter V,A,F,KW,KVA,PF,THD g) 2 Nos. of Under Voltage/Over Voltage Relay. Incomer:- (DG Side) a) 2 Nos 800A, 50 kA, 4P, ACB EDO μP based with O/C, E/F, Releases & S/T, O/V relay b) 2 Set RYB Indication Lamp c) 2 Nos (0- 800)A three phase digital ammeter d) 2 Nos (0-500)V three phase digital voltmeter e) 2 No. of Multifunction Digital meter V,A,F,KW,KVA,PF,THD f) 1 No 1600A 50 kA 4P ACB EDO μP based as Buscoupler Outgoings:- a) 10 Nos 630 A 50 kA TPN MCCB EDO,μP based b) 6 Nos 400 A, 50 kA, TPN MCCB EDO,μP based c) 1 No 320 A 50 kA TPN, MCCB EDO μP based d) 1 No 400A TPN,Isolator d) ON-OFF-TRIP Lamps with 2A fuse -18 sets e)Surge Protection Devices for Main Panel: Type 1-2 sets f) MFDM supporting RS485, with 2A fuse as per SLD -18 sets, 1600 A 415V,50kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. All Breakers in the incoming side shall be with LSIG protection and all the breakers in the outgoing side shall be with LSI protection. ON/OFF/TRIP indicators shall be provided for all the breakers (incoming & outgoing). Necessary spreader terminals, extended ROH, phase barriers, shrouding etc shall be as per the rules. Details as shown in SLD.

1

-

-

... More
DG Synchronisation Panel:-Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.a)DG Incomer 1,2,3 - DG1 - 800A 50 kA, 4P, EDO, ACB DG 2 - 500A 36KA TP MCCB and 500A TP AC3 duty power contactor ,DG 3 - 320A 36KA TP MCCB and 300A TP AC3 duty power contactor with thermal O/L, voltage controlled O/C relay, over voltage, under voltage, negative sequence, low set stand by earth fault relays and ref/differential relay + Neutral contactor b)RYB Indication Lamp c) 2A fuse d) **/5A CL:1, 15VA CT of suitable rating e)Three phase digital Ammeter of suitable rating f)(0-500)V three phase digital voltmeter g)Multifunction Digital meter V,A,F,KW,KVA,PF h)Synchronization Relay for DG Incomer - 3 Nos i) AC3 duty ,3P NL Contactor of suitable rating j)51G relay k)kWH meter for DG Outgoings:- a) 800A,50kA, FP, EDO Microprocessor Based ACB - 3 Nos b) 3 Sets of ON-OFF-TRIP Lamps with 2A fuse c)2 nos. of MFDM supporting RS485,with 2A fuse and CT 1600 A 415V, 50kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Necessary interlocking arrangement.All Breakers in the incoming side shall be with LSIG protection and all the breakers in the outgoing side shall be with LSI protection. Details to be as shown in SLD.

1

-

-

... More
HVAC Chiller Panel: Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42,Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. . Incomer:- a)630 A, TPN Isolator b)1 Set RYB Indication Lamp c) 2A fuse d)630/5A CL:1, 15VA CT e)1 No (0-630)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 320A,36kA, TP+ NL Thermal Magnetic Based MCCB - 4 Nos. b) 160A, 36kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. c) 5 nos. of MFDM supporting RS485,with 2A fuse and CT d) ON-OFFTRIP Lamps with 2A fuse. 630A 433V,36 kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Details to be as shown in SLD.

1

-

-

... More
HVAC Pump Panel : Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42,Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.a)Incomer - 160 A TP+ NL Isolator - 1 No. b)1 Set RYB Indication Lamp c)1 No (0-160)A three phase digital ammeter d)1 No (0-500)V three phase digital voltmeter e)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a)32A, 25kA, TP+ NL Thermal Magnetic Based MCCB - 10 No. b)80A, 25kA, TP+ NL Thermal Magnetic Based MPCB - 2 Nos. ON-OFF-TRIP Lamps with 2A fuse as per SLD 160A, 433V best conductivity extensible Al TPN bus bar with SMC supports,heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
MEDICAL EQUIPMENT PANEL:Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be selfsupported,free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level.All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.Incomer:- a) 630 A TP+ NL Isolator - 1 No. b)1 Set RYB Indication Lamp e)1 No (0-630)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 315A, 36kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. b) 250A, 36kA, TP+ NL Thermal Magnetic Based MCCB - 2 Nos. c) 100A, 36kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. d) 120A, 36kA, TP+ NL Thermal Magnetic Based MCCB - 1 Nos. e) 80A, 36kA, TP+ NL Thermal Magnetic Based MCCB - 1 No.f)50A, 36kA, TP+ NL Thermal Magnetic Based MCCB - 1 No,7 Sets of ON-OFF-TRIP Lamps with 2A fuse and 7 Nos. of Multifunction Digital meter V,A,F,KW,KVA,PF 630A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
MEDICAL GAS PLANT PANEL: Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be selfsupported,free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level.All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)100A TP +NL Isolator - 1 No. b)1 Set RYB Indication Lamp c) 2A fuse d)100/5A CL:1, 10VA CT e)1 No (0-100)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 63A 25kA TP+ NL MCCB, with thermal magnetic release - 3 Nos. b) 40A 25kA TP+ NL MCCB, with thermal magnetic release - 4 Nos. d)7 Sets of ON-OFF-TRIP Lamps with 2A fuse.100A 415V best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Details to be as shown in SLD.

1

-

-

... More
COMMON SERVICE PANEL Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be selfsupported,free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level.All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a) 630 A TP+NL Isolator - 1 No. b)1 Set RYB Indication Lamp c)1 No (0-630)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 320A 36kA TP+ NL Thermal Magnetic Based MCCB - 1 No. b) 250 A 36kA TP+ NL Thermal Magnetic Based MCCB -1No c) 200 A 36kA TP+ NL Thermal Magnetic Based MCCB - 3 Nos d) 160A 36kA TP+ NL Thermal Magnetic Based MCCB - 1 No e) 100 A 36kA TP+ NL Thermal Magnetic Based MCCB - 4 Nos,10 Sets of ON-OFF-TRIP Lamps with 2A fuse and 10 Nos. of Multifunction Digital meter V,A,F,KW,KVA,PF. 630 A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports,heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
SDB EV CHARGING : Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 100A TPN ISOLATOR b)1 Set RYB Indication Lamp c)3 Nos 100/5A CL:1, 15VA CT d)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a)1 Nos 63A, 25 kA, TM TPN,MCCB b) 6 Nos 25A, 25 kA, TM TPN, MCCB 100A 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
LIFT PANEL SSB -1 Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a) 250 A TP+NL Isolator - 1 No. b)1 Set RYB Indication Lamp. Outgoings:- a) 200A 25kA TP+ NL Thermal Magnetic Based MCCB - 2 Nos. b) 80 A 25kA TP+NL Thermal Magnetic Based MCCB - 3 Nos, 5 Sets of ON-OFF-TRIP Lamps with 2A fuse, 250A 433V,25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
LIFT PANEL-TYPICAL Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.a)Incomer - 63 A, TPN Isolator - 1No. b)1 Set RYB Indication Lamp Outgoings:- a) 63A, 100 mA, FP, RCBO - 1 No. b) 25A 30mA, DP RCBO - 1 Nos. c) 6A SP MCB - 4Nos. 63A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Details to be as shown in SLD.

6

-

-

... More
LIFT PANEL -SSB 2 Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)Incomer - 160A, TP+NL , Isolator - 1No. b)1 Set RYB Indication Lamp Outgoings:- a) 63A 4P 25kA TM MCCB - 5 Nos. b) 32A 4P MCB - 1No 160A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Details to be as shown in SLD

1

-

-

... More
PLUMBING PANEL:-Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. a)Incomer - 200 A TP +NL Isolator - 1 No. b)1 Set RYB Indication Lamp c)1 No (0-200 )A three phase digital ammeter d)1 No (0-500)V three phase digital voltmeter e)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a)125A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. b) 80A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 3 No. c) 63A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 2 No d) 50A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. e) 40A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 2 Nos. f) 25A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 2 No. 11 Sets of ON-OFF-TIP Lamps with 2A fuse. 200A, 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
GF FLOOR PANEL Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported,free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc.Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies:ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory Incomer:- a)1 No 160A 4P ATS b)2 Set RYB Indication Lamp c)1 No (0-160)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 100 A, 25 kA, TPN,TM, MCCB - 1 Nos b) 50 A, 25 kA, TPN,TM, MCCB - 2 Nos c) 40 A, 25 kA, TPN,TM, MCCB - 1 No e) 32 A, 25 kA, TPN,TM,MCCB - 4 Nos 160 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Details to be as shown in SLD

1

-

-

... More
1F and 2F FLOOR PANEL Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be selfsupported,free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level.All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 100A 4P ATS b)2 Set RYB Indication Lamp c)1 No (0-125)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 50 A, 25 kA, TPN,TM, MCCB - 3Nos b) 40 A, 25 kA, TPN,TM, MCCB - 1 No c) 32 A, 25 kA, TPN,TM, MCCB - 4 Nos 100 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Details to be as shown in SLD.

2

-

-

... More
3F FLOOR PANEL Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be selfsupported,free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better.Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys,switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note:Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 125A 4P ATS b)2 Set RYB Indication Lamp , Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 1No b) 50 A, 25 kA, TPN,TM, MCCB - 3 No c) 40 A, 25 kA, TPN,TM, MCCB - 1 Nobrc) 32 A, 25 kA, TPN,TM,MCCB - 3 Nos. 125 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Details to be as shown in SLD.

1

-

-

... More
4F and 5F FLOOR PANELS Supply,Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be selfsupported,free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level.All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory... Incomer:- a)1 No 63A 4P ATS b)2 Set RYB Indication Lamp c)1 No (0-100)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 50 A, 25 kA, TPN,TM, MCCB - 1Nos b) 40 A, 25 kA, TPN,TM, MCCB - 1 No c) 32 A, 25 kA, TPN,TM, MCCB - 6 Nos 100 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Details to be as shown in SLD

2

-

-

... More
6F FLOOR PANEL Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be selfsupported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 200 A 4P ATS b)2 Set RYB Indication Lamp c)1 No (0- 200)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a)100A, 25 kA,TPN,TM, MCCB - 3 Nos b) 80 A, 25 kA, TPN,TM, MCCB - 3 Nos c) 32 A, 25 kA, TPN,TM, MCCB - 6 Nos. 200 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Details to be as shown in SLD.

1

-

-

... More
5F OT PANEL Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported,free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc.Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies:ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 125 A 4P 25 kA, TM, MCCB b)1 Set RYB Indication Lamp c)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 50 A, 25 kA,4P,TM, MCCB - 8 Nos b) 8 Set ON OFF TRIP Indication c) 8 Set Multifunction Digital meter with CT 125 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Details to be as shown in SLD.

1

-

-

... More
5F UPS PANEL Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be selfsupported,free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys,switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level.Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance.OEM certification is also mandatory. Incomer:- a) 1 No 160 A 4P ATS b) 2 Set RYB Indication Lamp c) 1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 160A, 25kA, TP+ NL, MCCB - 1No. b) 50A 25kA , TP+NL , MCCB - 1 No. c) 32A 25kA , TP+NL ,MCCB - 1 No. 160 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports,heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
UPS OUTPUT PANEL Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note:Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)250A, 4P Isolator - 1 No. b) 1 Set RYB Indication Lamp c)1 No (0-250)A three phase digital ammeter d)1 No (0-500)V three phase digital voltmeter e) 1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 250A, 36kA, 4P, MCCB - 3 Nos. b) 125A, 36kA, 4P, MCCB - 1 Nos 250 A 433V, 36kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
APFC PANEL -150 kVAr :-Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Adequate forced ventilation arrangement shall be provided by means of a cubicle type fan of capacity 225 m3/hr also with contactor thermostat control. Control fuses shall be provided for the fan circuit. Lamp indication shall be provided to indicate the working/ non- working states of the fan. The capacitor compartment shall be so constructed that in case of any capacitor failure, fluid leakage or fumes from the field capacitor shall not affect the capacitors in the other compartments. The inter-compartmental partition of capacitor chamber shall be perfectly done. The capacitor shall be rated for a voltage 480 V or above and conform to IS - 2834. Incomer a)1 No 320A TPN Isolator b)2 Set RYB Indication Lamp c)1 No 2A HRC Fuse d)3 Nos 320/5A CL:1, 10VA CT e)1 No (0-320)A three phase digital ammeter f)1 No (0-500)V three phase digital voltmeter g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings a) 1No. 160A TPN,36kA MCCB b) 2Nos. 80A TPN,36kA MCCB c) 1 No. 63A TPN,36kA MCCB d) 2Nos. 32A TPN,36kA MCCB e) 2Nos. 20A TPN,36kA MCCB Capacitor: 50kVAR Capacitor Duty Contactor - 1No 25kVAR Capacitor Duty Contactor - 2 Nos 20kVAR Capacitor Duty Contactor - 1 No 10kVAR Capacitor Duty Contactor - 2 Nos 5 kVAR Capacitor Duty Contactor - 2 Nos 50kVAR Heavy Duty Capacitor Box Type resin Filled - 1No 25kVAR Heavy Duty Capacitor Box Type resin Filled - 2 Nos 20kVAR Heavy Duty Capacitor Box Type REsin Filled - 1 No 10kVAR Heavy Duty Capacitor Box Type REsin Filled - 2 Nos 5 kVAR Heavy Duty Capacitor Box Type REsin Filled - 2 Nos 7% detuned reactor – 8nos.8 Stage APFC Relay - 1 No Complete with all Control Wiring Components such as Control Contactors, Selector Switch, Push Button with Elements, Control MCB's etc. as required

2

-

-

... More
DISTRIBUTION BOARDS

-

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43)

26

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+18) - three phase double cover (IP 42/43)

16

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - three phase double cover (IP 42/43)

18

-

-

... More
90.11.1.13 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 12 way (8+36) - three phase double cover (IP 42/43)

6

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
90.11.1.21 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 12 way (8+36) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

17

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

5

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

4

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

26

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

22

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A 4P 100mA RCCB

6

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A 4P 100mA RCCB

38

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

6

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

2

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1520

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

12

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

40

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

52

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

12

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

9

-

-

... More
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories,connections, testing and commissioning etc as required and as instructed by engineer in charge also making good anydamages made during installation. 250A FP Isolator.

2

-

-

... More
SUPPLY AND FIXING OF LIGHT FIXTURES

-

-

-

... More
SITC of LED Tube Lights of 34W(+/- 10% Tolerance) with minimum system lumens 3740 Lumens Extruded Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection inbuilt with electronic drive system, , SDCM5 and CCT in between 4000K to 5700K, power factor /= 0.95, THD10%,rated life of 50,000 hours at L70, system efficacy110 lm/W, with a CRI 80, or above, Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes

212

-

-

... More
SITC of LED recessed downlight fixture Maximum 10W light fixture. System efficacy 110 lm/W and system lumen output not less than 1800 lm. Luminaire shall have satin finished translucence (HET) diffuser for uniform illumination and wider light distribution with Die Cast Al powder coated housing,driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor /=0.95,THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19,SDCM5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same

212

-

-

... More
SITC of LED recessed downlight fixture Maximum 16W light fixture. System efficacy 110 lm/W and system lumen output not less than 1800 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing,driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor /=0.95,THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19,SDCM5 and CCT in between4000K to 5700K, Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire / Drive shall be BIS approved of same.

287

-

-

... More
SITC of LED recessed downlight fixture Maximum 18W light fixture. System efficacy 110 lm/W and system lumen output not less than 1980 lm. Luminaire shall have satin finished translucence (HET)diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing,driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor/=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19,SDCM5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%,ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLSPVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted,Luminaire/Drive shall be BIS approved of same

123

-

-

... More
SITC of 2x2 LED Recess mounted light fixture 42W Clean Room light fixture. Bottom Opening frame.System efficacy 110 lm/W and system lumen output not less than 4620 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system,power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 22, SDCM5 and CCT in between 4000K to 5700K, Luminaire shall be flicker free with ripple content is less than 5%,ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted,Luminaire/Drive shall be BIS approved of same

24

-

-

... More
SITC of 2x 2 LED Recess mounted 36W light fixture, system efficacy 110 lm/W and system lumen output not less than 3960 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 22, SDCM5 and CCT in between 4000K to 5700K.Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make.

534

-

-

... More
SITC of LED Mirror Lights of Maximum 10W light fixture, System efficacy =100 lm/W and system lumen output not less than 1000 lm. driver with minimum 2.5KV internal surge protection with electronic drive system, power factor /=0.95, THD=20%, rated life of 50,000 hours at L70 with a CRI 80, SDCM5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided andincluding connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make.

76

-

-

... More
SITC of 10W LED BULKHEAD LIGHT fixture , System efficacy=100 lm/W and system lumen output not less than 1000 lm. , driver with minimum 2.50 KV internal surge protection with electronic drive system,power factor 0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, SDCM5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make

49

-

-

... More
SITC of 2x 2 LED Recess mounted 24W light fixture, system efficacy 110 lm/W and system lumen output not less than 2640 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 22, SDCM5 and CCT in between 4000K to 5700K.Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make.

451

-

-

... More
SITC of 3W LED skirting lamp (foot lamp) to provide dim lighting to make path during night, including necessary accessories required for connection.

216

-

-

... More
90.15.3.7 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 8 Meters

26

-

-

... More
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

26

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod,2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

428

-

-

... More
Supply of 450 mm sweep Exhaust fan with Metal blades and metal frame of approved colour, quality and complete the work in good condition as directed by the engineer in charge.

150

-

-

... More
Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc as required.

150

-

-

... More
EXTERNAL FEEDER PILLAR:-Supply and installation of Thermoplastic polycarbonate Junction Box IP67. Junction box should be made of thermoplastic Polycarbonate, having IP 67 degree of protection and 5pole terminals suitable to terminate up to 2.5sqmm. The color of Junction boxes shall be Siemens Grey RAL7035. The gasket should be internally embedded, and made of Polyurethane The boxes shall be tested as per IEC 60670-2 / 60670-22. The boxes shall have self- threaded holes & provision for mounting din rail, The boxes should withstand temperature of -40c to +120c, The glow wire test should be conducted at 960c, and material should be flame retardant & self- extinguishing. UL subject 94, V-0. The boxes should be free of toxic substances like halogen and silicon, The boxes should have suitable premolded knock out, suitable size IP68 polyamide glands shall be provided for in and out cables / wires. Incomer:25A, 30mA RCBO, Outgoing: 8nos. 6/10/16/20A 10KA SP MCBs.

1

-

-

-

-

-

... More
150KVA Modular(N+1) UPS:-Supply, installation, and commissioning of MODUALAR UPS 1X150 kw FRAME with maximum 25kw modules in each frame of 3 phase modules three phase in and out and indoor (IP20) with surge protection system having 15 min backup battery @125 kW load battery sizing calculation to be provided from the OEM, with isolator for each bank battery of reputed approved make ,Input pf 0.99, Input THDi 3%, double conversion technology with input 400V, 50Hz three phase, output 400V, 50Hz three phase, SNMP card for network monitoring, BMS compatibility etc. It shall be 100% generator compatible, with Efficiency 96 % and output power factor Unity (kva = kW), Eco mode Efficiency 99% and including all accessories etc as required. The acoustic noise at 1m of the system should be80dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE,IEC62040-4 or ISO14025 or equivalent relevant IS standard. The system shall be true online double -conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have 3 level IGBT rectifier and inverter. including rack and interconnecting cables. Battery backup time required is 15 Min. using external SMF batteries. The product offered sufficient battery Ah capacity for required backup.

1

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

10

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

12

-

-

... More
Supply and fixing single line diagram, schematic diagrams etc. of A0 size on suitable Aluminium sheet including lamination etc. as required complete on wall.

2

-

-

... More
Painting letters or figures of 2.5cm/4.5cm sizes with enamel paint as identification mark to SB, DB, panel board etc as required

1

-

-

... More
Supply and providing 2.5/3 mm thick and 1 m wide electrical grade chequered type elastomeric rubber mat to withstand 11 kV dielectric strength conforming to IS 15652 : 2006

20

-

-

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold or , duly painted over a coat of primer. Cost inclusive of providing 4 Nos of sand filled fire bucket and MS stand frame.

12

-

-

... More
Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.

8

-

-

... More
Supply and providing First Aid Box.

2

-

-

... More
Supply and providing 6mm thick MS chequered plates duly painted. Plates to be cut size as per site requirement.

28

-

-

... More
Supplying and Providing 15" long rubber hand gloves

2

-

-

... More
LT Cabling and End Termination

-

-

-

... More
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp

82

-

-

... More
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

177

-

-

... More
90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm

30

-

-

... More
90.12.7.32 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm

202

-

-

... More
90.12.7.33 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm

96

-

-

... More
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

362

-

-

... More
90.12.7.35 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm

206

-

-

... More
90.12.7.36 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm

278

-

-

... More
90.12.7.37 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm

1364

-

-

... More
90.12.7.13 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp

95

-

-

... More
90.12.7.14 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp

715

-

-

... More
90.12.7.15 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required 3 core 16 sq mm with factory made clamp

60

-

-

... More
90.12.7.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp

50

-

-

... More
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp

110

-

-

... More
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

1786

-

-

... More
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

690

-

-

... More
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp

91

-

-

... More
90.12.7.43 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp

240

-

-

... More
90.12.1.38 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 4 sq mm

65

-

-

... More
90.12.1.43 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 35 sq mm

60

-

-

... More
90.12.1.32 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 120 sq mm

100

-

-

... More
90.12.1.36 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 300 sq mm

90

-

-

... More
90.12.1.37 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 400 sq mm

120

-

-

... More
90.12.1.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm

45

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, Copper conductor 2XFY powercable confirming to IS 7098 (part 1) amended up to date. 1CX185 sq mm cu cable

200

-

-

... More
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.185 sq mm

20

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.12CX2.5 (Cu Control cable)

198

-

-

... More
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.12Cx2.5 Sqmm Cu Control cable

72

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

50

-

-

... More
9.1.16 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 185 sq. mm (57mm)

8

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

4

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

16

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

2

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

8

-

-

... More
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

6

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

34

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

12

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

6

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

56

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (19mm)

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 4 sq. mm (19mm)

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 6 sq. mm (19mm)

8

-

-

... More
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

6

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

158

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

56

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

14

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

22

-

-

... More
EARTHING

-

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)

816

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor ( 8 SWG)

165

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

980

-

-

... More
90.16.3.10 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm copper strip

295

-

-

... More
90.16.3.16 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)50 x 6 mm copper strip

198

-

-

... More
90.16.4.8 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm copper strip

118

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

48

-

-

... More
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)

40

-

-

... More
Supply of all materials and providing plate earth station with 1200 x 1200 x 12.5 mm. C.I. plate earth electrode, water pipe, earthing strips, clamps, funnel, Electrodes etc., excavation in all classes of soil,terminal filling with homogeneous mixture of charcoal and salt and back filling ,construction of Earthpit Inspection Chamber and Heavy duty C.I. Chequered plate for Earthpit Inspection Chamber cover. The rate quoted shall be including the excavation, construction of chamber, CI cover & back filling

11

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. 50X6 Cu strips tinned at the joints

245

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge / consultant. 25x3 Cu strips tinned at the joints

214

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. 25x6 Cu strips tinned at the joints

270

-

-

... More
LIGHTNING PROTECTION SYSTEM

-

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required.a) 3 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories

4

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminal for mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. 3 meter air terminal with Interception Tip mounted on Concrete Stone & Stainless Steel mounting accessories

4

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminum rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination; Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminal for mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. 4 meter air terminal with Interception Tip mounted on Concrete Stone & Stainless Steel mounting accessories

7

-

-

... More
Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Conductor with Parapet Holder made of whether resistant plastic holder @ every 0.5 meters

280

-

-

... More
Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters

945

-

-

... More
Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Conductor with Terrace Conductor Fibre Reinforce Concrete holder @ every 0.75 meters

480

-

-

... More
Providing and fixing of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece with Connector: to route vertical down conductor /mesh formation made of Aluminium Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp/clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC 62305). Make sure all joints are strong and will be inspected at site. Galvanised Iron joints are not permitted to avoid risk of corrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required.

90

-

-

... More
Providing and fixing of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor & 10mm dia copper coated solid steel round conductor having 100 microns of copper bonding . Conforms to the requirements according to (IS/IEC 62305).The enclosure should be outdoor glass-fibre reinforced polycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. The test link has to be straight and needs minimum 4 mounting screws for strong joints. Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium & 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors should not touch eachg other to avoid bimetallic corrosion. Single bolt joints are not permitted. Govt approved Indian labs test certificate required.

25

-

-

... More
Providing and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required.

455

-

-

... More
Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305. Each under ground joints has to be wrapped with petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm. Govt approved Indian labs test certificate required.

30

-

-

... More
Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467. The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1second and I peak of 76 KA. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 m. It should be free from hazardous substances.The mineral compound is required to have minimum 17.5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with weight bearing capacity of 30KN. The dimension shall be 320mmx320mmx 190mm. Govt approved Indian labs test certificate required.

8

-

-

... More
RISING MAINS,BBT AND TAP OFF BOXES

-

-

-

... More
Supply, installation, testing and commissioning as per IEC 61439 Part 6 indoor prefabricated sandwich type epoxy insulated compact (TPN with 100% neutral) Rising Mains IP54 enclosure with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating for use on 3 phase 4 wire 415 V 50Hz AC on wall, with high conductivity aluminium conductor with provision for tapping and fixing Tap off boxes.The bus bar shall be complete with flange end bends expansion joints end cover elbow copper flexible and connections wherever applicable as per site conditions made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 nos aluminium bus bars, continuous external earthing with 2 nos copper strip of 25 x 3 mm size (one on each side) including GI clamping brackets, suspenders angle iron bracket steel fasteners connecting to earthing system etc. as required. 630 amps 50KA Rising Mains.

54

-

-

... More
Supply, installation, testing and commissioning as per IEC 61439 Part 6 indoor prefabricated sandwich type epoxy insulated compact (TPN with 100% neutral) Rising Mains IP54 enclosure with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating for use on 3 phase 4 wire 415 V 50Hz AC on wall, with high conductivity aluminium conductor with provision for tapping and fixing Tap off boxes.The bus bar shall be complete with flange end bends expansion joints end cover elbow copper flexible and connections wherever applicable as per site conditions made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 nos aluminium bus bars, continuous external earthing with 2 nos copper strip of 25 x 3 mm size (one on each side) including GI clamping brackets, suspenders angle iron bracket steel fasteners connecting to earthing system etc. as required. 250 amps 36KA Rising Mains.

45

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets,angle iron bracket steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished 100A/63A 50kA 4P MCCB in Tap off box

4

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets,angle iron bracket steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished 125A 50kA 4P MCCB in Tap off box

6

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets,angle iron bracket steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished 160A 50kA 4P MCCB in Tap off box

2

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets,angle iron bracket steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished 200A 50kA 4P MCCB in Tap off box

2

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets,angle iron bracket steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished 200A 36kA 4P MCCB in Tap off box

2

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets,angle iron bracket steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished 100A 36kA 4P MCCB in Tap off box

4

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets,angle iron bracket steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished 63A 36kA 4P MCCB in Tap off box

6

-

-

... More
Supplying, installation, testing & commissioning of following capacity End Feed Unit for the existing sandwich Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated including 630A 50KA TPN MCCB and necessary joints with clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 630 amps 50KA SC for 1 sec

2

-

-

... More
Supplying, installation, testing & commissioning of following capacity End Feed Unit for the existing sandwich Type bus trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated including 250A 36KA TPN MCCB and necessary joints with clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 250 amps 36KA SC for 1 sec

2

-

-

... More
Supply, erection, testing and commissioning of following capacity auto transfer switch with enclosure, bus bars and all accessories required for complete operation as per the drawing. The ATS should be double break contact system for high short time withstand. ATS shall be with UV/OV, Phase sequence, Single phasing and frequency protections.63A 4P ATS WITH ENCLOSURE

5

-

-

... More
Extra Low Voltage System Data

-

-

-

... More
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT6A Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

40

-

-

... More
CAT6 Cable - Supplying and laying of Category 6 LSZH cable including fluke testing through Conduits/Cable tray as directed by Engineer/Consultant in charge.

33600

-

-

... More
CAT 6A Cable - Supplying and drawing of Category 6A cable consists of 4 pairs of solid insulated copper 23AWG,LSZH,(complying IEEE802.3 AF and IEEE802.3 AT) Fluke testing with reports, labeling, as built drawings, with 25 years manufacturer warranty in the existing surface/recessed steel/ PVC conduit as required. as instructed by engineer in charge/consultant

2700

-

-

... More
OFC Cable - Supplying and drawing of 12 core MM (OM3/OM4) armored Optical Fiber Cable (OFC), LSZH through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

820

-

-

... More
RG6 Cable - Supplying and drawing of RoHS 2011/65/EU Compliant RG6 Co-axial cable Compliant less than 13.5 dB loss at 3000 MHz as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

1180

-

-

... More
RG11 Cable - Supplying and drawing of RoHS 2011/65/EU Compliant RG11 Co-axial cable less than 10 dB loss at 3000 MHz through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

160

-

-

... More
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT6 Information Outlets (Key stone) with Shuttered Face plate, Single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

360

-

-

... More
Outlet RG6 - Supply, fixing and commissioning of RG6 Outlet & Rg6 Satellite cable Socket with face plate, white, jack, suitable PVC / GI Modular Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

20

-

-

... More
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6A Patch Cable - 2 Meter length etc. of approved make as required for complete installation.

39

-

-

... More
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 2 Meter length etc. of approved make as required for complete installation.

247

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 1 Meter of approved make as required for complete installation.

455

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of Multi-Mode Fiber Patch Cable (LC) Duplex - 2 Meter of approved make as required for complete installation.

40

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6A, 24 port fully loaded patch panel with rear cable management including crimping Splicing & patching of cable with Fluke report. with all accessories required for complete installation as required as directed by the engineer in charge.

3

-

-

... More
Supply and Installation of 20 Pair MDF Box with Crone and necessary Patch cables to connect with patch panel.

7

-

-

... More
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6A Patch Cable - 1 Meter length etc. of approved make as required for complete installation.

44

-

-

... More
Supply & fixing IP65 rated Box for keeping connection inside box along with RJ45 Connectors for safe and secure termination -It should be protected from Dust and water -This RJ45 connector should get 25 years OEM Performance Warranty.

95

-

-

... More
Supply, erection, testing and commissioning of following pair krone Box with mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 300 Pair(150x2) MDF Krone along with necessary patch Cords to connect with PABX system

1

-

-

... More
Supplying and laying of following pair armored telephone cable through wall /tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 50 Pair Telephone Cable

70

-

-

... More
Supplying and laying of following 20pair armored telephone cable through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

410

-

-

... More
Supply and Installation of 30 Pair MDF Box with Crone and necessary Patch cables to connect with patch panel/ System.

1

-

-

... More
Supply and Installation of 50 Pair MDF Box with krone with necessary patch cables to connect with patch panel/System.

1

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

3280

-

-

-

-

-

... More
Supply, Installation, Testing & Commissioning IP based PBX . Supply, Installation, Testing and Commissioning of "IP PBX " with 150 Analog extensions 10 Ip extension and expandable up to minimum 500 Extensions, 1 ISDN PRI interface, 4 analogue trunk lines, 4 SIP trunk, 8 Port IVR , Web Interface,Call Dashboard, DISA, IVR, Call Hunt etc. including one Qty of IP/Digital Operator key phone & short key/ Direct Station Selection (DSS) Console and audio cable to connect with amplifier.

1

-

-

... More
Supply, Installation, Testing & Commissioning IP Phone with the basic features.

2

-

-

... More
Basic Analog Telephone

50

-

-

... More
CLOSED CIRCUIT TELEVISION

-

-

-

... More
Dome - Supply, Installation, testing and commissioning of IP based 2.8/3.6 mm to 9/12 mm varifocal lens or near, 2MP resolution, POE (Power over Ethernet), H.264 / H.265, Min 1/3" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 30 meters IR range, 120 dB WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge.NDAA Complied as per Tender specs

60

-

-

... More
Camera - Bullet - Supply, Installation, testing and commissioning of Motorized Varifocal Bullet Camera with Minimum 2 MP, IP 67,Power Over Ethernet (POE), H.264 / H.265, built-in IR LED, 2.8/3.6 mm to 9/12 mm or near , Minimum 30 meters IR range, SD Card Slot,120dB WDR, Alarm I/O, BLC with all connectors and necessary accessories for mounting in false ceiling/True Ceiling as required for complete installation as directed by Engineer in charge. CE/FCC approved, ONVIF S/G/T.NDAA Complaint. BIS Certified

13

-

-

... More
Network Video Recorder with Storage: Supply, installation, testing and commissioning of 64 Channel Network Video Recorder with Recording Storage for 30 days, supports minimum up to 12 MP Camera resolution, Supports minimum upto 12 TB per Slot ,ONVIF supporting, should support dual video HDMI output, Should Support H.265, H.264 & H265+ at real time, Should Support minimum 500 MBPS for Incoming and Outgoing ,Network Camera recording. (Consider the sufficient HDDs for 720p @ 20 FPS @H265 Compression for 30 days continues recording for all channels). Storage calculation details shall be submitted. Should Support analytical features like Face Detection, Perimeter Intrusion Detection, Line Crossing Detection, License Plate Detection -Wireless Mouse to be included for Operation.

2

-

-

... More
Indoor Dome Camera - IP network true day/night indoor Dome PAL color Camera with min 1/3" Progressive scan CMOS min 2 MP resolution image sensor, H.265, H.264 codec supported. Multi streaming , with built in 2.8 / 3.6 / 4 / 8mm lens as required,IP66, IK10, PoE, in indoor dome housing with built in WDR (120DB) ,BLC, 30mts IR distance or above, Memory Card Slot, PoE, Motion detection,Privacy masking, Alarm I/O, also with the capability to add manufacturer's power supply unit if required at site and with built in WEB Browser and required wall / ceiling mounting accessories as specified in the Tender Specifications. ONVIF Supported, with all mounting accessories as required.

28

-

-

... More
LED Display - Supply, installation, testing and commissioning of 40 inch full HD LED display including bracket 24 x 7 with HDMI input Setup including necessary connection, HDMI cable, rating tray etc. as required for complete installation with all accessories as required and directed by engineer in charge.

2

-

-

... More
Monitoring PC Station Intel Min i5 processor or greater with min 8 GB RAM ,2 GB Dedicated Graphics card,512 GB SSD, 1 TB HDD, Network Interface 10/100 MBNIC, Scroll Mouse & Keyboard, 1No. 21" LED CCTV Monitor, original Windows Softwire original OS (Windows ) software, min 2 Serial Ports, 1 Parallel port, 4 USB Ports, 2 Expansion slots. VMS/CMS software for CCTV integration.

1

-

-

... More
PUBLIC ADRESSING SYSTEM

-

-

-

... More
Ceiling Speaker-6W ceiling speaker with 100V Matching transformer-with Metal grille and spring clamp-

221

-

-

... More
Wall Mounted Speaker - Supply, fixing, testing and commissioning of Cabinet Speakers with inbuilt line matching transformer with power 12W Cost inclusive of necessary interconnection connection wire etc. required for complete installation.

41

-

-

... More
Power Amplifier - Supply, fixing, testing and commissioning of Power Amplifier of 480 Watts with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.

6

-

-

... More
Controller - Supply, fixing, testing and commissioning of Master zone controller with routing zone capacity of 12 zones with all accessories and necessary connections including necessary cables and jacks as required for complete installation. The work also include integration with Fire Alarm System (FAS) including to play the pre-recorded message in case of fire and evacuation as per Technical Specs.

1

-

-

... More
Call Stations - Supply, fixing, testing and commissioning of 6 Zone Calling Station with addition 6 Zone Calling PAD with mic as per tender specs as required for complete installation.

1

-

-

... More
Audio/Video player - Supply, installation, testing & commissioning of Audio/Video player with USB option with all accessories like jacks and codes for complete installation as required as directed by the Engineer in charge.

1

-

-

... More
Speaker Cable - Supplying and drawing of 2 Core, Twin Twisted, Armored Speaker cable,16 AWG for speakers with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

2240

-

-

... More
ACCESS CONTROL SYSTEM

-

-

-

... More
Supply, Installation, Testing & Commissioning of IP Based 4 Door Controller with minimum 4 Readers, min 8 inputs with enclosure, power supply and all the necessary accessories with software. supports 30,000 credentials and 30,000 PIN codes

4

-

-

... More
Supply, Installation, Testing & Commissioning of IP Based 2 Door Controller supports 2 Wiegand reader controller. 4 inputs and 4 output. Power plug and supports cable locks, for secured wiring, option of DIN rail mounting. Cable twist locks and zip-tie anchors for better cable management. tamper sensing, and power status LED. single/dual door modes, Full online/offline operation. 30,000 Users, 20,000 event history. UL certified with enclosure, power supply and all the necessary accessories including integration with Fire alarm system.

2

-

-

... More
Supply installation Testing and commissioning of Card based Access Reader-Contactless 13.56 MHz: minimum up to 7 cm, supporting Bluetooth, Wiegand, Weather-resistant, UV-resistant, IP65, epoxy-potted.

10

-

-

... More
Supply of Access Cards-MIFARE® Classic - 1K - ISO Card (PVC)

150

-

-

... More
Supply, Installation, Testing & commissioning of 600 lbs double leaf EM Lock with ZL bracket and all necessary accessories

8

-

-

... More
Supply, Installation, Testing & Commissioning of Access control system Software for managing access control system and time attendance system all basic details Attendance Report for min 500 users, Visitor Management ,Status Maps ,Card + Card mode , Card Design (Photo ID) ,User Counters ,Global Antipas back, Operators, Intrusion Integration. Single software Interface and Dual Software platform is acceptable for access and Attendance. All the Access control should be linked in one software and door should be controlled in case of any emergency.

1

-

-

... More
Supply, fixing, testing and commissioning of exit switch with Faceplate, suitable PVC / GI Modular Back Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by Site Engineer/Consultant

10

-

-

... More
Supply, fixing and commissioning of break glass with Faceplate, with suitable Backbox in recess/ surface mounted including necessary connections with all accessories required for complete installation as directed by Engineer in Charge.

10

-

-

... More
Biometric / Card Reader with on board TCP/IP facility with display. Biometric Controller with Display (Inbuilt controller with Finger and Card ,Live & Fake Fingerprint Detection ,min 1.5" Screen ,min 9,000 FP Templates * 13.56 Mhz Mifare card 1,00,000 Transactions Storage Capacity IP65 (Weather Proof) Wiegand , TCP/IP. Option should be there to connect with PMS/HMS as per requirement.

2

-

-

... More
Supply, Installation, Testing & commissioning of 600 lbs single door EM Lock, ZL Bracket with all necessary accessories

2

-

-

... More
Supplying and drawing of 4C X 1Sqmm Multistranded copper cable for Controller to EM Lock through surface / recessed medium class PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge / consultant and making good all damages made for installation.

260

-

-

... More
Supplying and drawing of 8C X 1 Sqmm Multi stranded Copper Cable for Controller to Reader with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

100

-

-

... More
ACTIVE COMPONENTS RACKS AND ACCESSORIES

-

-

-

... More
Supply, Installation, Testing and installation of Cat - 6, 24 port fully loaded patch panel with necessary cable manager for routing the cable inside rack with all accessories required for complete installation as required as directed by the engineer in charge.

37

-

-

... More
Supply, Installation, Testing and installation of 24 Port Manageable Core Switch (Layer 3) with following components with minimum 240 Gbps Back Plane Module, Throughput Aggregate Min. - 190 Mpps, Should have of 20 ports 10G SFP + and 4 Qty of 10G Copper ports, with all other required accessories to fix in the cabinet contains minimum 1-year onsite support, should include Management Port, as per the confirmation and requirement of the site Engineer/Consultant

2

-

-

... More
Supply, Installation, Testing and Commissioning of 24 Port Smart/Manageable PoE Switch -Cat - 6, POE, 24 x Gigabit Ethernet + 4 x 10G SFP+ , switch with 4Stack/upstream 10G port on SFP+, rack mounting brackets, with all accessories required for complete installation as required as directed by the engineer in charge. The switch should be capable to provide sufficient power budget to IP cameras as per the requirement.

1

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6, 48 port 10/100/1000 Mbps with 4 x10 G SFP+ uplink Port, Manageable/Smart Managed POE-370 Watts, switch with rack mounting brackets, with all accessories required for complete installation as required as directed by the engineer InCharge. Back Plane should be considered as per bandwidth requirement

12

-

-

... More
1G-MMF -Transceiver compatible with proposed Core Switch and Layer 2 Switch with all accessories required for the configuration and completion as per confirmation with the Engineer

28

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6, 24 port 10/100/1000 Mbps with minimum 4 SFP+, Manageable POE, switch with rack mounting brackets, with all accessories required for complete installation as required as directed by the engineer in charge. Back Plane and PoE should be considered as per bandwidth and Power requirement of the Camera. Minimum 5% additional PoE power than the actual power usage of the camera should be considered in the Switch.

7

-

-

... More
10G SFP+- compatible with core switch and Layer 2 Switch-10G SFP+ LC 300mtrs OM3 MMF Transceiver

12

-

-

... More
Wireless access points with dual radio, 5GHz 802.11ac 4x4 MIMO and 2.4GHz 802.11ac 2x2 MIMO (IEEE 802.11ac) with a coverage radius of Min. 25 Mtrs. standalone & Manageable by controller

3

-

-

... More
Supply, Installation, Testing and installation of 12 port Light Interface Unit (LIU) / Fiber Patch Panel, rack mountable with mounting brackets, loaded with Adaptors, Couplers Multi Mode (MM) pigtails with splicing and OTDR Report with all accessories required for complete installation as required as directed by the engineer in charge.

7

-

-

... More
od165916/2023_2024 : Supply, Installation, Testing and Commissioning of 24 port Light Interface Unit (LIU) / Fibre Patch Panel, rack mountable with mounting brackets, loaded with Adaptors, Couplers Multi Mode (MM LC type pigtails with splicing and OTDR Report with all accessories required for complete installation as required as directed by the engineer in charge.

3

-

-

... More
36U 800x800 Floor mount rack-glass door-rear door-3" caster set-4 fcooling fan-required numbers of pvc cable manager - blank panels as required to cover the vacant spaces-metal cable channel 100mm width x 1600mm height -8/12 socket Power distribution box with 32 Amp MCB as per requirement-industrial plug 32A with power cable 6Sqmm 3 meter length -Mounting hardware packet and Shelves as per the requirement.

2

-

-

... More
15U Wall mounted Rack with Front glass door,with handle Lock & key. Front/Rear 15U mounting angles, top, bottom open, including necessary exhaust / circulation fan, PDU with all other accessories required for complete installation as directed by the engineer in charge.

4

-

-

... More
SITC of 24U Wall/floor Mount Rack with power distribution unit, cable managers, fans and other accessories.

2

-

-

... More
Supply, installation, testing and commissioning of 42U Rack with Front glass door, Rear Perforated door with handle Lock & key, castors. Side and rear panels, Front / Rear 42U 800Wx1000D MM mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan with all other accessories required for complete installation as directed by the engineer in charge.

1

-

-

... More
Supply and fixing of Pre-Galvanized closed raceway with Cover ,horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories .The Tray shall be galvanized for corrosion protection .The trays should be tested for a max. safe working load of 1.5 times than the actual ,1.6 mm thickness with cover in ceiling and shafts, floor etc with complete MS supports and Galvanized accessories fabricated per site requirements. It should also include the cost of bends, tees etc as required. 400 x 60 x 1.6 mm thick

41

-

-

... More
Supply and fixing of Pre-Galvanized closed raceway with Cover ,horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories .The Tray shall be galvanized for corrosion protection .The trays should be tested for a max. safe working load of 1.5 times than the actual ,1.6 mm thickness with cover in ceiling and shafts, floor etc with complete MS supports and Galvanized accessories fabricated per site requirements. It should also include the cost of bends, tees etc as required. 200 x 60 x 1.6 mm thick

370

-

-

... More
Supply and fixing of Pre-Galvanized closed raceway with Cover ,horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories .The Tray shall be galvanized for corrosion protection .The trays should be tested for a max. safe working load of 1.5 times than the actual ,1.6 mm thickness with cover in ceiling and shafts, floor etc with complete MS supports and Galvanized accessories fabricated per site requirements. It should also include the cost of bends, tees etc as required.150X60X1.6mm thick

190

-

-

... More
SERVICE BLOCK

-

-

-

... More
Indoor/OUTDOOR BULLET -IP network true day/night IP67 rated outdoor Wall / Pole Mount Bullet PAL Colour Camera with min 1/3" Progressive scan CMOS/ Progressive scan CCD /CMOS - min 2 MP resolution image sensor, with min one H.264/H265 stream for recording & one H.264/H265 stream for live viewing. It shall have the capability to deliver two independent video streams and shall be possible to set independent FPS (30 fps for H.264) & Compression selection with built in fixed lens 2.8/3.2/3.6/4mm lens / near to that , with built in 120dB WDR , HLC /BLC circuitry, Min 30mts IR distance POE connectivity and also with external power supply with built in WEB Browser. ONVIF with all mounting accessories as required-

6

-

-

... More
Network Video Recorder with Storage: Supply, installation, testing and commissioning of 8 Channel Network Video Recorder with Recording Storage space server for 30 days, Supports 1080P resolution video recording at real time, NVR ONVIF supporting, Recording resolution of Min 4 MP, should support dual video HDMI output, H.265,H.264 at real time. (Consider the sufficient HDDs for 720p @ 20 FPS for 30 days continues recording for all channels).Storage calculation details shall be submitted.-Wireless Mouse to be included for Operation

1

-

-

... More
Supply, Installation, Testing and installation of Cat - 6, 8 port 10/100/1000 Mbps, layer 2, POE, switch with rack mounting brackets, minimum 2 numbers of SFP+, with all accessories required for complete installation as required as directed by the engineer in charge. The switch should be capable to provide sufficient power budget to IP cameras as per the requirement. Backplane capacity to be calculated and Switch should be selected accordingly.

1

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 1 Meter LSZH of approved make as required for complete installation.

6

-

-

... More
CAT6 Cable - Supplying and drawing of Category 6 cable consists of 4 pairs of solid insulated copper 23AWG LSZH (complying IEEE802.3 AF and IEEE802.3 AT) Fluke testing with reports, labeling, as built drawings,

360

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6,24 port fully loaded patch panel with rear cable management including crimping / Splicing & patching of cable Fluke testing including all accessories required for complete installation as required as directed by the engineer in charge.

1

-

-

... More
Supply & fixing IP65 rated Box for keeping connection inside box along with RJ45 Connectors for safe and secure termination -It should be protected from Dust and water -This RJ45 connector should get 25 years OEM Performance Warranty.

6

-

-

... More
Supply, installation, testing and commissioning of 15U Rack with Front glass door with handle Lock & key. Front/Rear mounting angles, top, bottom open, including necessary exhaust / circulation fan with all other accessories required for complete installation as directed by the engineer in charge

1

-

-

... More
Fire Protection System Fire Pump_Control Panel and Pump room Pipe

-

-

-

... More
MAIN PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Hydrant Pump Set: Electrical Driven, Capacity: 2280 LPM at 75 Meter Head, conforming to IS 1520,with Bronze Impeller, S. S. Shaft, Mechanical Seal, Squirrel Cage Induction Electric Motor, Suitable HP,3Ph, 50 Hz, suitable RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and necessary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

1

-

-

... More
SPRINKLER PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Sprinkler Pump Set: Electrical Driven, Capacity: 2280 LPM at 75 Meter Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, Squirrel Cage Induction Electric Motor,Suitable HP, 3Ph, 50 Hz, suitable RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and necessary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

1

-

-

... More
JOCKEY PUMP - Supply, installation, testing and commissioning of Jockey Pump: Electrical Driven, Capacity: 180 LPM at 80 Mtrs. Head, Vertical Multi Stage Inline Pump with S.S Impeller, Mechanical Seal, and with High Efficient IE-3 Rated Squirrel Gauge Induction Motor, Suitable HP, 3Ph, 50 Hz, 3000 RPM, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve,anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions

2

-

-

... More
DIESEL PUMP - Supply, installation, testing and commissioning of Stand By / Back Up Fire Pump, Horizontal long coupled, End Suction Pump, Engine Driven, suitable for Automatic operation and consisting of the following and complete in all respect as required; Capacity: 2280 LPM at 75 Meter Head conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, coupled to High Efficient Radiator Cooled Diesel Engine, Suitable HP, 2150 RPM, and with Control Panel with Auto Starting Facility, by activation of concerned Pressure Switch and thro. 12V/24 V Electric Starter, Battery of adequate rating and with Battery Charger, Battery Leads, Diesel Tank for 6 hrs operation, exhaust pipe extended up to 1 mtr outside pump house, duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, complete with necessary civil foundation, foundation bolts, compound gauge, water re-circulation arrangement,pressure relief valve, and all other necessary fixing accessories, all as per Technical Specifications

1

-

-

... More
Supply, erection, commissioning of additional length of Exhaust Pipes with MS Class B, long radius bend from silencer with necessary clamps, fixtures, civil works and thermal insulation with 50 mm thick rock wool and with 1.0 mm thick aluminum sheet cladding of following adequate size including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. The horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger.Exhaust pipe of required height shall be provided according to latest CPCB norms

50

-

-

... More
Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Incomings 400A, 50kA 4 Pole MCCB,Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500Amps Outgoings ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pumps 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets Jockey Pump 63 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote,auto/manual/OFF operation. - 2 sets Diesel Engine Control Control for diesel engine comprising -Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification

1

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 300 mm dia.

14

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 250 mm dia.

15

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia -200mm

25

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia- 150mm

15

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia- 100mm

5

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 80mm

5

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 65mm

5

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 50mm

12

-

-

... More
Providing, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete. Dia - 300mm.

2

-

-

... More
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12,Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 300mm

2

-

-

... More
Hydrant System_Fire Pipes Valves and Accessories

-

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia -200mm

76

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia- 150mm

1465

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia -100mm

160

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 80mm

215

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 65mm

170

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 50mm

515

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 40mm

500

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 32mm

675

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coal tar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.80 mm dia.

514

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 25mm

2320

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia.

337

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required-200 mm. dia

57

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia.

1180

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16,conforming to IS: 13095 with nuts, bolts etc. complete. 250mm

1

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. 200mm.

1

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. 150mm.

3

-

-

... More
Providing, fixing, testing and commissioning of Gun Metal Non Return Valve, PN-16, b Vertical / Horizontal Type , as per final requirement, conforming to IS: 13095 with nuts, bolts etc. complete. 50mm.

2

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze / gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 250 mm dia.

2

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 200 mm dia.

7

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze / gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia.

25

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze / gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia.

2

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze /gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 65 mm dia

3

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc.Dia - 80mm

1

-

-

... More
Providing, fixing, testing and commissioning of Ball Valve, PN-16 Forged Brass & Nickel / Chrome Plated, conforming to IS: 9890, UL Listed and FM approved with Screwed Female Ends to BS:21, and with non-corrosive handle / lever, including necessary accessories and connections. Dia - 50mm

18

-

-

... More
Providing, fixing, testing and commissioning of Ball Valve, PN-16 Forged Brass & Nickel / Chrome Plated, conforming to IS: 9890, UL Listed and FM approved with Screwed Female Ends to BS:21, and with non-corrosive handle / lever, including necessary accessories and connections. Dia - 25mm

8

-

-

... More
Providing, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete. Dia -150mm

1

-

-

... More
Supply, installation, testing and commissioning of Pressure Switches with pressure rating 4 to 14 Bar with a differential of 0.2 to 1.6 Bar (however; should be suitable for Fire Pumps) and with ¼” BSP (F) inlet connection and screwed cable entry for fixing cable gland. It shall also be complete with Stainless Steel Isolation Cock, Nipples, tail, connecting pipes etc.

5

-

-

... More
Supply, installation, testing and commissioning of 4" dia. Bourdon Type Pressure Gauge, with ISI Mark or of equivalent International Standards. Weather / Water Proof Type, Pressure Range: 0 to 16 Bar, with Stainless Steel Shut off Cock, Syphone Pipe, Snubber etc.

2

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

1

-

-

... More
Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark,Stainless Steel-304 body with 63mm. oblique instantaneous single outlet, 75mm. N.B. flanged inlet,Stainless Steel -304 spindle, complete with PVC blank cap, G.I. chain etc.

67

-

-

... More
Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided /rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm dia isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set

24

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)

128

-

-

... More
Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark.

64

-

-

... More
Supplying, installing and commissioning of fire brigade inlet, inlet connection of 4 way with 4 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main as well as to Fire water tank. Qouted rate shall be included with M.S. cabinet (painted - inside and outside) of suitable size with mounting supports etc. complete.

2

-

-

... More
Supply, installation, testing and commissioning of Fire Brigade Draw Off Outlet C.I. body, having 3 Gunmetal, 63mm. female instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 3 nos. of rubber blank caps and G.I. chains.

1

-

-

... More
Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement.

46

-

-

... More
Supply and fix at site in position Weather proof Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door,with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement

15

-

-

... More
Providing and fixing sight glass assembly of brass body and brass ball with chrome plated, steel handle,PN16 or above, UL Listed & FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems with grooved end connection ends. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass.

16

-

-

... More
Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including isolation valve and necessary accessories and connections

8

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories.68 Degree centigrade Pandent Sprinkler.

1150

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories. 68 Degree centigrade Upright Sprinkler.

808

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage, Standard Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in -charge, with necessary accessories and fittings. Pendant type - 79 Deg.C (For kitchen)

14

-

-

... More
Supply, installation, testing and commissioning of Hydraulically Operated Fire Sprinkler Alarm Valve (Installation Control Valve), Flanged / Grooved Ends (as per final requirement without any cost variation).complete with Constant Pressure Trim Assembly, Water Motor Gong, Control Valves, Pressure Switch,Pressure Gauges etc. Including all necessary fixing accessories, all as per Technical Specifications. The control cabling from Pressure Switches to concerned Monitor Module shall be measured with proposed Fire Alarm System. The Alarm Valve and the Total Parts / Components / Accessories shall be UL Listed / FM approved. Dia - 200mm

1

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 16 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System., all as per Technical Specifications. The control cabling from flow switches to concerned Module shall be measured with proposed Fire Alarm System.Dia - 150mm

16

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 16 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System, all as per Technical Specifications. The control cabling from flow switches to concerned Module shall be measured with proposed Fire Alarm System.65 mm dia

1

-

-

... More
Providing, Fixing, Testing and Commission Flexible Sprinkler Hose of adequate size; UL Listed, FM Approved, 25mm. (1") BSP Male Inlet, 15mm. (1/2") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, length: 1500 mm, and with all connecting systems and accessories

900

-

-

... More
Providing & Fixing 2 Piece Chrome Plated Friction Fit recessed escutcheon for pendant sprinklers, as per requirement.

1307

-

-

... More
Intelligent Addressable Fire Alarm System

-

-

-

... More
Supply, install, test and commission Intelligent Addressable Fire Alarm Control Panel (FACP) as per the technical specification and not limited to having Visual Display Unit (VDU) preferably 640-character LCD display with Battery Back-up for 24 hours for normal operation and 1 hours on alarm condition. The control panel, battery charger etc, shall be UL listed approved. The panel / panels should be equipped with Loop Cards of adequate capacity as per manufacturer recommendation to incorporate the devices and detectors for this project considering 20% spare capacity in each loop. The panels shall be networked together (in case of more than a panel) and capable of networking with other compatible panels. The panel should be expandable to add another Loop card.

1

-

-

... More
Supply, install, test and commission Intelligent Addressable Network Repeater Panel (NRP) with minimum Color display, This NRP shall act as an independent node communicating on the peer to peer network and shall not be dependent on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of NRP operation. The Unit shall be complete in all respect and the Cost of Panel shall inclusive of Network Communication Module(s) (NCM), for networking with the Main Fire Alarm Panels. Panel shall be UL listed and FM approved. All as per Technical Specifications

1

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Multi Sensor Detectors. The detectors shall have multiple sensitivity (adjustable at site) levels, programmable for timed automatic sensitivity selection complete with Standard Base, junction box and other accessories as required. Detectors shall be UL listed and FM Approved.

720

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Heat Detector and with rate of rise of temperature feature, programmable for timed automatic sensitivity selection with Standard Base, junction box and other accessories. Detectors shall be UL listed.

1

-

-

... More
Supply, installation, testing and commissioning of Response indicator for all detectors located above false ceiling

270

-

-

... More
Providing, fixing test and commission Intelligent Addressable Manual Call Station Point with addressable module that monitors and reports contact status, etc

62

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Weather / Water Proof / Corrosion Resistant type Manual Call Point having an integrally mounted addressable module that monitors and reports contact status, IP67 rated, complete .

5

-

-

... More
Providing, fixing, test and commission Conventional Type Horn/Strobe rated at 82 dB @3Mtr. for audible annunciation and 75Candela flashing at 1Hz. for visual indication.

61

-

-

... More
Providing, fixing, testing and commission Intelligent Addressable Input / Monitor Module, for interface with Flow Switches, Fire Pumps, Supervisory Switches, Alarm Valve, Water Tank Level etc.

85

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Control Module, for interface with Fire Alarm Annunciating System, Lift Panels, Public Address System etc.

20

-

-

... More
Providing, fixing,, test and commission Intelligent Addressable Relay Module, for interface with AHUs, Ventilation System, Smoke Management System, LPG System, Power Distribution etc. (This quantity shall be tentative / approximate only, shall change as per final design of the other systems and final requirement)

70

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected, all as per technical specifications.

50

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

200

-

-

... More
Supply, laying, testing and commissioning o 2Core x 1.5 mm2 FRLS Armoured Cables with Red Colour / Finish.

12250

-

-

... More
Fire Extinguishers

-

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.ABC Dry Chemical Powder, Store Pressure Type - 4 Kg.

30

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.ABC Dry Chemical, Store Pressure Type - 2 Kg.

80

-

-

... More
ABC powder type fire extinguisher with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc. complete, confirming to IS:15683.6 Kgs.

5

-

-

... More
Clean Agent Modular Type Ceiling mounted Fire Extinguisher 5 Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with Charge of Clean agent (Gas) is also known as HFC Blend A, It is a blend of Hydro Fluoro carbon and organic detossificant essence P26. The sprinkler body will comprise of temperature sensitive quartsoid bulb of temperature rating of 680. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling. The Extinguisher shall be externally epoxy powder coated as per IS: 5 Color Shade No. 538(For Server room)"5 Kgs

10

-

-

... More
FIRE Signages

-

-

-

... More
Signage Printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.25cm. height letters in red with white back ground and standard size (500x225 mm) as per conventional design/colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of screws and double tape or hanged from the false ceiling with the help of chain and screws etc. complete as required as per the technical specification.

86

-

-

... More
Floor Identification Signage ( ie, GROUND FLOOR, FIRST FLOOR, etc.) at each stair enclosure on every floor, indicating the floor number in words, of standard size (500x225mm) as per conventional design/colour code on 3mm thick aluminium screws and double tape of hanged from the false ceiling with the help of chain and screws etc. complete as required as per the technical specification.

36

-

-

... More
Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) standard size (500x225 mm as per conventional design / colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of chain and screws etc. complete as required as per the technical specification.

65

-

-

... More
Supply and installation of photoluminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER),of standard size (600x800mm minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws and double tape or hanged from the false ceiling with the help of chain and screws etc. complete as required as per the technical specification

92

-

-

... More
Providing and fixing in position the signages " Fire Hydrant " it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2' x 3'.

27

-

-

... More
Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size: 300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red / Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum), with 4 Hr. Battery Backup.Single Side Display

52

-

-

... More
Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size: 300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red / Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum), with 4 Hr. Battery Backup.Double Side Display

24

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
FIRE SEALANT for Internal Shafts - Supply and Fixing of load bearing Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57:Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1 g/l as per LEED 2009. Firestop installation should be done by trained applicators (HAFSC) and in accordance with manufacturer's guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemical anchoring along the length and breadh of the shaft and provide 2 layers of chicken mesh etc. The mortar shall be applied with a minimum thickness of 65 mm & having load bearing capacity of 200kg/sqm.Proper engineering judgement needs to be submitted through the manufacturer. Complete installation report through Software CFS DM shall also be submitted for inspection purpose

71

-

-

... More
Providing 150mm. Puddle Flange for Roof Level (Terrace) Fire Water Tank, Fabricated, Hot Dip Galvanised and Fix in Position, all as Per Tender Drawings and Technical Specifications.

1

-

-

... More
TALK-BACK SYSTEM

-

-

-

... More
Supply, installation, testing & commisioning of automatic control console of 8 zones micro process based complete with floor to floor announcing and talk back facilities with the following features and made functional: (a) Feather type key pads to select the zones. (b) Moulded plastic attractive enclosure. (c)Backlight Liquid Crystal Display(LCD) (d) User friendly interactive display. (e) Announcement selector - PH Switch. (f) Listen selector switch. (g) All Call switch to select all zones simultaneously for announcement (h) Zones Call Display On the LCD With Audio Alarm. Panel to be installed in the Fire

1

-

-

... More
Controller Unit with 120 W amplifier, Goose neck type microphone and with the following features: (i) Built in Power supply. (ii) Zone Selector switching Circuit (iii)Terminal blocks to terminate zones wires, amplifier wires etc., (iv) Zone Call processing Circuit etc and made functional. Panel to be installed in the Fire Control Room.

1

-

-

... More
Supply, installation, testing and commisioning of Public Address speaker with talk back facility 6 Watts with L M T and call switch, made out of powder coated CRCA sheet, wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting.

57

-

-

... More
Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armored Cables with Green / Blue Colour / Finish, as per Technical Specifications. (Approx. Quantity for Networking)

4000

-

-

... More
Providing, laying, test and commission 2Core x 1.5 mm2 FRLS Armoured Cables, Underground, laid in Trenches with required protection, all as per Technical Specifications. Cost for connected civil Work / Trenches shall measured and accounted separately. (Approx. Quantity)

200

-

-

... More
HVAC Works Water Chilling Plant

-

-

-

... More
Supply at site including local transport with full cover insurance, fire or any other contingencies, unload,store, handle, erect, balance, test and commission the entire water chilling plant as per specifications including all accessories as specified for water chilling plant. WATER COOLED SCREW CHILLER - (R-134A/410) OF MINIMUM CAPACITY 100 TR. Minimum Overall Chiller efficiency offered shall have COP 5.8 AS PER ECBC + Buildings 2017/ ASHRAE / ARI 550/590 & IPLV 7.1. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F, Comprising of Screw Compressor as per specifications. Drive motors of IE3 ratings 415+/- 10% Volts 50 Hz AC supply and starter panel with star delta starter. Water cooled condenser with all accessories. Automatic capacity control unit to regulate the capacity down to 25%.Micro-processor control panel. Building management system compatible software Data Link / Micro Gateway for integration with third -party BMS on Modbus / BACNET protocol, Safety controls as per spec. wiring and interlock between pumps shall be included in the chiller cost. The cost for additional incoming metering panel for each chiller to be included in the chiller. Water cooled chiller with all accessories:LOT-integral mounting frame for all the components, LOT-refrigerant piping & valves, LOTinsulation of chiller and suction line, LOT-first charge of refrigerant and lube oil, LOT-vibration isolation pads. LOT-Thermometer for water inlet and outlet and water flow switches. MCCB's as a part of the chiller. Copper cable & isolators for chiller to be included in the chiller cost. R.C.C foundation along with PCC/RCC sub base with fixing of foundation bolts and nuts, spring mounts and finishing the slabs as well as openings and finishing of civil structures. Condenser, Compressor and Evaporator shall be manufactured by OEM. Chiller shall be ASME 'U' stamped.

3

-

-

... More
PUMPS AND COOLING TOWER

-

-

-

... More
Supply, installation, testing & commissioning the chilled water primary pumps as per specification including all accessories as specified and as required. Including inertia base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long Coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti-vibration springs. guards etc. including insulation as per specifications. Pump efficiency shall be minimum 75% as per ECBC + Buildings 2017. Capacity: 240 USgpm, 1440 RPM (Suggested) Head: 45 feet, Motor efficiency shall be IE3.

3

-

-

... More
Supply, installation, testing & commissioning the chilled water secondary pumps as per specification including all accessories as specified and as required. Including inertia base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Pump efficiency shall be minimum 75 % as per ECBC + Buildings 2017. Capacity : 240 USgpm, 1440 RPM (Suggested), Head: 90 feet, Motor efficiency shall be minimum IE 3.

3

-

-

... More
Supply, Installation, Testing & commissioning of Variable Frequency Drive complete IP 20 VSPS control panel (IP 55 if panel is to be installed under open air) consisting of adjustable frequency drive (AFD) for each pump, one dedicated microprocessor based pump controller per zone housed within this enclosure panel with parallel pumping software duly down loaded and single / multiple differential pressure sensor / transmitters as per the site requirement. The entire system along with secondary pumps as described above must be sourced from single manufacturer only, to ensure unit responsibility. The VFD should be incorporated with RFI (radio frequency interface) filters which can control THDi [Total Harmonic Distortion Current] below 5%, auto bypass starter compactable to the third party bms. VFD shall be IEEE 519 complied and third party test certification shall be produced for IEEE519 Compliance

1

-

-

... More
Supply, Installation, testing & commissioning the condenser water pumps as per specification including all accessories as specified and as required. Including inertia base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq. Cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long Coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti-vibration springs. guards etc. including insulation as per specifications. Pump efficiency shall be minimum 75 % as per ECBC + Buildings 2017. Capacity: 400 USgpm, 1440 RPM (Suggested) Head: 70 feet, Motor efficiency shall be minimum IE 3.

3

-

-

... More
Supply, Installation, testing & commissioning the cooling towers as per specification including all accessories as specified and as required. COOLING TOWERS of actual capacity complete in all respects as per technical specifications and equipment schedule complete with FRP casing, FRP fan cylinder,PVC louvers, PVC drift eliminator polypropelene nozzles, drive assembly, HDG fan guard/bird screen,non-clogging nozzle type water distribution system. PVC fill, GI ladder, make up water, quick fill, drain overflow connections etc. as per specifications. Including R.C.C foundation along with PCC/RCC subbase, fixing with bolts and nuts and finishing the slabs or any opening, Control panel, VFD drive sensors and cabling to be considered.VFD shall operate with sensing the temperature difference from inlet and outlet of the cooling tower. Cooling towers shall meet or exceed the minimum efficiency requirements for ECBC+ buildings.100 TR - CTI/JCI approved induced draft, counter flow cooling tower with vertical air discharge. EWT = 97.5 degree F, LWT = 90 degree F, WET bulb = 82 degree F, Flow rate = 400 USgpm, Fan Motor efficiency shall be minimum IE 3, VFD shall comply with IEEE519 standard.

3

-

-

... More
DOUBLE SKIN AIR-HANDLING UNITS WITH VFD AND PLUG FANS and THERMAL BREAK

-

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/ powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU with heater banks shall comprise of strip heaters of mentioned capacity comprising -thermostat, humidistat, safety thermostat, contactors,Controls & control Wiring."20 TR 8000 CFM, 4 row. Double Skin Floor mounted Horizontal AHU with mixing Box

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab,CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHUwuith heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat,humidistat, safety thermostat, contactors, Controls & control Wiring."17 TR 6800 CFM, 4 row. Double Skin Floor mounted Horizontal AHU with mixing Box and fine filter& Ultraviolet Germicidal Irradiation lamp

4

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab,CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU with heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat,humidistat, safety thermostat, contactors, Controls & control Wiring. "20 TR 8000 CFM, 4 row. Double Skin Floor mounted Horizontal AHU with mixing Box and fine filter

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab,CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU with heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat,humidistat, safety thermostat, contactors, Controls & control Wiring. " "15 TR 6000 CFM, 4 row. Double Skin Floor mounted Horizontal AHU with mixing Box and fine filter

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab,CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU wuith heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat, humidistat, safety thermostat, contactors, Controls & control Wiring. "12 TR 4800 CFM, 4 row. Double Skin Floor mounted Horizontal AHU with mixing Box, 2 x 3 KW Heater

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab,CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU wuith heater banks shall comprise of strip heaters of mentioned capacity comprising -thermostat, humidistat, safety thermostat, contactors, Controls & control Wiring. "11 TR 4400 CFM, 4 row. Double Skin Floor mounted Horizontal AHU with mixing Box and fine filter

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab,CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU wuith heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat,humidistat, safety thermostat, contactors, Controls & control Wiring."10 TR 4000 CFM, 4 row. Double Skin Floor mounted Horizontal AHU with mixing Box

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab,CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU wuith heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat, humidistat, safety thermostat, contactors, Controls & control Wiring. "9 TR, 3600 CFM, 4 row. Double Skin Ceiling Suspended AHU with mixing Box"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab,CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU wuith heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat,humidistat, safety thermostat, contactors, Controls & control Wiring. "5 TR, 2000 CFM, 4 row., Double Skin Ceiling Suspended AHU, 3 KW Heater

1

-

-

... More
"Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab,CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU wuith heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat, humidistat, safety thermostat, contactors, Controls & control Wiring."4 TR 1600 CFM, 4 row. Double Skin Floor mounted Horizontal AHU with mixing Box "

1

-

-

... More
"Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU wuith heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat,humidistat, safety thermostat, contactors, Controls & control Wiring. "4 TR 2400 CFM, 6 row. Double Skin Ceiling Suspended AHU with VFD, 10 micron pre filters, Thermal break - for UPS Room

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section,coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static AHU wuith heater banks shall comprise of strip heatersof mentioned capacity comprising -thermostat,humidistat, safety thermostat, contactors, Controls & control Wiring. " "TREATED FRESH AIR UNIT WITH HEAT RECOVERY WHEEL, VFD, SUPPLY & RETURN FANS" "Supply at site, including, local transport, unload, store, handle, erect, balancing, testing and commission of the entire HRW as per specifications including all accessories as specified and as required. Summer Ambient conditions:DBT – 95 deg F, WBT- 82 Deg F Return Air condition: DBT- 75 Deg F , RH– 55% Supply Fan Static - 60 to 70 mm WG Return fan - 40 mm to 60 mm WG Efficiency 80- 85%.TFA - 27 TR AHU, 9.4 sq.ft./ 8 Row coil with 5000 CFM Supply fan, 4700 CFM Return fan and heater coil of 2 x 3KW.(Heater banks shall comprise of strip heaters of mentioned capacity comprising -thermostat, humidistat, safety thermostat, contactors, Controls & control Wiring.)

1

-

-

... More
FAN COIL UNITS AND VAV

-

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage IE 3 rated induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Ystrainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop,extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF). 1.25 TR Hideway FCU.

1

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage IE 3 rated induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF). 1.5 TR Hideway FCU.

6

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage IE 3 rated induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF). 2 TR Hideway FCU.

5

-

-

... More
VAV (Variable Air Volume)Vav unit for supply air OF rectangular ducts with thermostats and controls Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate.Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV-1650 CFM

1

-

-

... More
VAV (Variable Air Volume) "Vav unit for supply air for rectangular ducts WITH THERMOSTAT AND CONTROLS Casing and damper blade made of galvanized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 2400 CFM

1

-

-

... More
CHILLED WATER PIPING AND VALVES

-

-

-

... More
16.3.5 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 200mm dia. (75mm thick expanded polysterene)

250

-

-

... More
16.3.6 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 150mm dia. (50mm thick expanded polysterene)

20

-

-

... More
16.3.7 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of Nominal size - 125mm dia. (50mm thick expanded polysterene)

100

-

-

... More
16.3.8 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (50mm thick expanded polysterene)

125

-

-

... More
16.3.9 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 80mm dai. (50mm thick expanded polysterene)

30

-

-

... More
16.3.10 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 65mm dia.(50mm thick expanded polysterene)

295

-

-

... More
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)

275

-

-

... More
16.3.12 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 40mm dia. (50mm thick expanded polysterene)

300

-

-

... More
16.3.13 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 32mm dia. (50mm thick expanded polysterene)

120

-

-

... More
16.3.14 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 25mm dia. (50mm thick expanded polysterene)

360

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping,plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves,strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 20mm dia. (50mm thick expanded polysterene)

350

-

-

... More
Site fabricated pipe (MS class C) with adequate structural support and with PUF injection insulation & AL cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection.100 mm dia.

110

-

-

... More
Site fabricated pipe (MS class C) with adequate structural support and with PUF injection insulation & AL cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection. 200 mm dia.

75

-

-

... More
DRAIN WATER PIPING:Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same.32 mm dia. PVC

10

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same." 25 mm dia. PVC

100

-

-

... More
"DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same." 20 mm dia. PVC

150

-

-

... More
16.7.1.1 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 200 mm

5

-

-

... More
16.7.1.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 125 mm

2

-

-

... More
16.7.1.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 80 mm

2

-

-

... More
16.7.1.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 65 mm

4

-

-

... More
16.7.1.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 50mm

20

-

-

... More
16.7.1.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 40 mm

24

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation: Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven." 100 mm dia

20

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation: Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven.32 mm dia

17

-

-

... More
Supply, installation, testing & commissioning of the following type forged Ball Valve, PN-20 gunmetal / Brass, including all necessary accessories and connections. 25 mm dia.

44

-

-

... More
Supply, installation, testing & commissioning of the following type forged Ball Valve, PN-20 gunmetal /brass, including all necessary accessories and connections. 20 mm dia.

1

-

-

... More
16.7.3.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE 100 mm dia

6

-

-

... More
BALANCING VALVE WITH PROVISION FOR FLOW MEASURMENT: Supply, installation, testing & commissioning of Balancing valve with built in measuring facility, C.I Body with EPDM seal, long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water as specified. Balancing Valve with 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning;flanged connections; Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/-, necessary insulation as per specification Balancing valve with built in measuring facility 100 mm dia

3

-

-

... More
SUCTION GUIDE with strainer: Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required.Size: 100 mm dia.

6

-

-

... More
16.7.4.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 65 mm dia

1

-

-

... More
16.7.4.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of Ductile of 50 mm dia

7

-

-

... More
16.7.4.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 40 mm dia

4

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified Y- Strainer of 32 mm dia

2

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified Y- Strainer of 25 mm dia

1

-

-

... More
PRESSURE GAUGE - For chiller, pumps, AHU:Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type,made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection : Brass, NPS 12mm dia bottom-outlet type, Dial: Satin-faced, non-reflective aluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

48

-

-

... More
THERMOMETERS - For chiller, pumps, AHU: Supply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

48

-

-

... More
Supply, installation, testing & commissioning of differential pressure switch as per the specifications and as required.

3

-

-

... More
16.11.3.7 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.100mm dia.

3

-

-

... More
500 L Pressurized Tank:Design, supply, installation, testing and commissioning of Pressurised chilled water expansion tank with Make up connection for closed loop system along with necessary pneumatic devices and accessories and MS 'C' section supports in order to keep chilled water under pressure.The tank shall be precharged steel tank with replacable heavy duty butyl rubber bladder.The tank shall have 50mm system connection and 20mm drain and charging valve connection to facilitate on-site charging of tank.The tank shall be fitted with lifting rings and floor mounting skirt for vertical installation.The tank shall be constructed according to section 8 of ASME boiler and pressure vessel code and stamped 125psi working pressure.The contractor shall submit calculation regarding the above data. Pumps shall be of N+1 configuration. including with control wiring.

1

-

-

... More
Supply, installation, testing & commissioning of a common air separator on the chilled water return line located at the pump suction and suitable for Secondary pump water flow; the separator shall be complete with high capacity air vent, flanges, service valve, non return valve, isolation butterfly valve for makeup water inlet.Capacity suitable for 720 USGPM and 200 mm NB CHW Header line.

1

-

-

... More
AUTO AIR VENTS including Ball Valves:Supply & install of airvents / purge valves including 15mm Ball Valves at the highest points in chilled water piping complete each floor with pipes nipple welded to pipe, hex nipple, socket, U-pipe connection at outlet of air vent etc. as required.

35

-

-

... More
Supply and fix flexible connections with control rods for pumps and chiller.Size: 100 mm dia.

18

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type).65 mm dia.

1

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE:Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type).50 mm dia.

7

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE:Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type).40 mm dia.

4

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE:Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type).32 mm dia.

2

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE:Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type).25 mm dia.

1

-

-

... More
CONDENSER WATER PIPING AND VALVES

-

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same.200 mm dia.

125

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specifications. Opening as good as same. 125 mm dia.

100

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specifications. Opening as good as same.100 mm dia.

20

-

-

... More
Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven.BUTTERFLY VALVE (MANUAL): Size-125 mm

18

-

-

... More
Supplying, fixing, testing and commissioning of following non return valves, in the condenser water piping and adequately supported as per specifications. Non- Return Valve of 125 mm dia

3

-

-

... More
Supply, installation, testing & commissioning of the following suction guides as per the specifications and as requiredSize: 125 mm dia

3

-

-

... More
Supply and fix flexible connections with control rods for pumps, cooling tower & condenser. Size: 125 mm NB

12

-

-

... More
Supply, installation, testing & commissioning of Balancing Valve, with built in measuring facility with C.I Body, 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections;Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/- Size: 125 mm NB

6

-

-

... More
THERMOMETERS - For chiller, pumps, AHU: Supply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

12

-

-

... More
PRESSURE GAUGE - For chiller, pumps, AHU: Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type,made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection : Brass, NPS 12mm dia bottom-outlet type, Dial: Satin-faced, non-reflective aluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification.

12

-

-

... More
16.11.3.6 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.125mm dia

6

-

-

... More
DUCTING, GRILLS, DIFFUSER AND INSULATION

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

1550

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

1000

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

200

-

-

... More
Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

3.75

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

2.5

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600X600 SD: 225×225

1

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600X600 SD: 300x300

15

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600X600 SD: 375×375

240

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 RD: 225×225

1

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 300x300

15

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 375x375

245

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification.300 mm dia

355

-

-

... More
Supply, Fabrication, installation and testing of following size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification.350 mm dia

10

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 300X300X350H

1

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 350X350X400H

15

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 450X450X400H

240

-

-

... More
SITC of Factory made fresh air dampers with louvers and control lever, filter etc as required. (as per drawing)

18

-

-

... More
SITC of Factory made fresh air dampers having 20 micron filter with louvers and control lever. (for OT as per drawing)

2

-

-

... More
Supply, fix, balance and commissioning of louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, brass bushings complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges, fixing arrangement etc, as per specifications. Al. volume control duct damper

12

-

-

... More
Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link & micro switch to shut of corresponding AHU (including control cable.)

17

-

-

... More
Supply & fixing of 25 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3. Moisture Diffusion Resistance Factor or ‘μ’ value of the base insulation material shall be minimum 7,000, thermal conductivity shall be 0.035 W/mk. R value of the insulation material shall comply with the ECBC + building standards.

2750

-

-

... More
Acoustic insulation: Supply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140- 180kg/m3

320

-

-

... More
VENTILATION SYSTEM

-

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : "1300 cfm Exhaust blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : " 1200 cfm Exhaust blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : " 1250 cfm Exhaust blower

3

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 550 cfm Exhaust Blower

12

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen Motor efficiency , IE 3 :2200 cfm Exhaust Blower

2

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 :1600 cfm Exhaust blower

2

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 :1500 cfm Exhaust blower

1

-

-

... More
Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 :1000 cfm Exhaust blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 700 cfm Exhaust blower

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 650 cfm Exhaust Blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 500 cfm Exhaust Blower

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 450 cfm Exhaust Blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 400 cfm Exhaust Blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 350 cfm Exhaust Blower

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioningDirect driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 300 cfm Exhaust Blower

7

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 250 cfm Exhaust Blower.

9

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 200 cfm Exhaust Blower

9

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 150 cfm Exhaust blower

11

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 100 cfm Exhaust blower

14

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 80 cfm Exhaust blower.

61

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

520

-

-

... More
Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification Size: 100mm dia

600

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

0.5

-

-

... More
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated,supply and return air grilles and diffusers.SIZE :150 X 150 MM Exhaust Grill

415

-

-

... More
ADDITIONAL WORKS

-

-

-

... More
Automatic type Chemical dosing system, for condenser water piping system(contious treatment) as per specification and drawing. Total package of flushing, chemical pre-cleaning, passivation and treatment with chemicals etc. with necessary permanently installed equipment's and its controls. This package includes initial analysing of make up water sample. Then programming methods and duration.Accordingly, supply, install, tesingt commissioning and maintain for a specified period with dosing pumps , tanks, water meters corrosion coupon tanks, valves with required chemicals and its micro-processor based controller with program etc. as per specification. Maintaining the clean piping system without corrosion, scale or micro-biological activity for an optimum operational efficiency and handing over the entire system in a healthy condition at the end of contract. which is the suppliers responsibility.Cost for supply of chemicals required for 3 years (contact period) passivation to be considered

1

-

-

... More
Initial Chemical treatment , for chilled water piping system with necessary temporarily installed equipment's - one time flushing, chemical pre-cleaning passivation with suitable chemicals. to make chilled water free of corrosion, scale or micro-biological activity for an optimum operational efficiency and handing over the entire system in a healthy condition at the end of the contract which is the suppliers responsibility

1

-

-

... More
UNDER DECK INSULATION - FOR ICU, OPERATION THEATRE, MRI, CT, ISOLATION ROOMS: Supply & fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3

2200

-

-

... More
Roof(inside) insulation for exposed slabs/walls: Supply & fixing of 12 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3

525

-

-

... More
ELECTRICAL WORK

-

-

-

... More
AHU PANEL 1:- Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.Incomer:- a)1 No 100A FP ISOLATOR b)1 Set RYB Indication Lamp Outgoings:- a)6 Nos 32A, 25 kA, TM FP, MCCB 100A 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
AHU PANEL 2:- Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42,Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Testcertificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 63A FP ISOLATOR b)1 Set RYB Indication Lamp Outgoings:- b)4 Nos 32A, 25 kA, TM FP, MCCB 63A 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
AHU PANEL 3:- Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42,Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 100A FP ISOLATOR b)1 Set RYB Indication Lamp Outgoings:- a)6 Nos 32A, 25 kA, TM FP, MCCB b)1 Nos 50A, 25 kA, TM FP, MCCB 100A 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
AHU PANEL 4 and 5 :- Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 100A FP ISOLATOR b)1 Set RYB Indication Lamp Outgoings:- a)5 Nos 32A, 25 kA, TM FP, MCCB b)1 Nos 50A, 25 kA, TM FP, MCCB 100A 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

2

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3.5CX 25 Sq.mm Al Cable

20

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3CX6 Sq.mm Al Cable

265

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3CX4 Sq.mm Al Cable

225

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date." 3 core x 1.5 sq mm copper Armoured Control cable

450

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date." 2 core x 1.5sqmm copper Armoured Control cable

125

-

-

... More
"Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date." 6 core x1.5 sq mm copper Armoured Control cable

150

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

2290

-

-

... More
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4CX4 Sq.mm Al Cable

104

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3CX6 Sq.mm Al Cable

24

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3CX4 sq.mm Al Cable

24

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. " 3C X 1.5 sq. mm

18

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. " 2C X 1.5 sq. mm

12

-

-

... More
"Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. " 6C X 1.5 sq. mm

42

-

-

... More
90.16.1.2 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 2.65 mm copper conductor (12 SWG)

300

-

-

... More
90.16.5.2 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 2.65 mm (12 SWG)

100

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

100

-

-

... More
90.16.3.10 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm copper strip

60

-

-

... More
90.12.7.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp

36

-

-

... More
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

252

-

-

... More
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

30

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

36

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

6

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4CX4 Sq.mm Al Cable.

6

-

-

... More
Supplying and fixing of FP 25/32/40amps 415 volts "C" curve FP MCB with sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required.

4

-

-

... More
supply and fixing of lockable off push button near pumps and Cooling Tower. Material shall be thermoplastic with minimum IP 65 rating.

12

-

-

... More
BUILDING MANAGEMENT SYSTEM

-

-

-

... More
Central core Computer - PC (Intel i7 Processor), 8 GB RAM, 2 GB Graphics card, DVD Writer, 22" LED monitor, 1 TB HDD, Microsoft mouse, Keyboards, 2 serial, 1 parallel port/KB, Windows 10 operating system, antivirus software with 5 years license..

1

-

-

... More
A4 Colour Laser printer

1

-

-

... More
System Controller to interface field level controllers to IBMS Workstation Supply, Installation,Testing and Commissioning of Building Management System Graphic User Interface software with 3 user client license, user groups, user profiles and scopes, alarm handling, scheduling, trending, reporting engine, database system, system activity log, historical data management, real time zoom enabled vector graphics, system backup and restore, HTML based documentation and help, SMS/Email facility complete in all respects as per tender specification. Graphical Software complete to cater to hardware points as specified in the Data Point Summary as well as Third Party Software Integrated Systems. Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Chiller System - (50 points/chiller)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Secondary Pumps System (10 Points/Pump

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Variable Frequency Drives for AHU's (10 Points per VFD)

1

-

-

... More
Networkable DDC Controllers as per Data Point Summary (1- 5) with enclosure with all necessary wiring and accessories

1

-

-

... More
Immersion Type Temperature Sensor

4

-

-

... More
Level Switch for expansion tank ( 2 point) (depth of tank - 1 mtr.)

1

-

-

... More
Differential Pressure Switch

6

-

-

... More
Level Switch for cooling tower

3

-

-

... More
Controls for Chiller System: Outside Air Temperature & RH Sensor

1

-

-

... More
Differential Pressure Sensor

1

-

-

... More
Air Handling Units - :Supply, Installation, testing & commissioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC

5

-

-

... More
Air Handling Units Supply, Installation, testing & commissioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC

14

-

-

... More
Supply, Installation, testing & commissioning of Differential Pressure Switch across filter

8

-

-

... More
Supply, Installation, testing & commissioning of Return air Temperature Sensor

24

-

-

... More
Supply, Installation, testing & commissioning of RH Sensor Room type.

13

-

-

... More
Supply, Installation, testing & commissioning of Differential Pressure Switch across filter- Pre filter, fine filter as required.

18

-

-

... More
Supply, Installation, testing & commissioning of Differential Pressure Switch across filter- Pre filter, fine filter and Hepa filter as required.

21

-

-

... More
Supply, Installation, testing & commissioning of Air Differential Pressure sensor.

7

-

-

... More
SITC of Signal Cabling - 2 Core 1.0 sq.mm. shielded FRLS armoured cable.

2000

-

-

... More
SITC of Signal Cabling - 4 Core 1.0 sq.mm. shielded FRLS armoured cable.

3500

-

-

... More
SITC Signal Cabling - 8 Core 1.0 sq.mm. shielded FRLS armoured cable.

1200

-

-

... More
SITC of Communication Cabling - 2 Core 1.5 sq.mm. shielded FRLS armoured cable or CAT5E armoured cable.

800

-

-

... More
SITC of Power Cable - 3 C X 2.5 SQMM -ATC Armoured Cable.

400

-

-

... More
SITC of Cable tray 150 x 50 mm.

200

-

-

... More
Supplying and installing following size of pre galvenised iron floor race way including cover, GI bolts & nuts, etc. as required

150

-

-

... More
Elevator System Passenger cum Bed Lift

-

-

-

... More
26 Passenger cum Bed Lift-Design, fabrication, supply. installation, testing and commissioning of 26 Passenger cum Bed Lift – Gear less with Machine Room, Capacity / Weight 26 Pass (1768 Kg), Speed 1.5 MPS, electric traction type, Stainless steel (Including freight & landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with prerecorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. PMSM traction motor ( having efficiency equivalent to IE3 or better as in (IS 12615) of machine room elevator shall be of gearless type and placed inside the machine roomcomplete as per technical specifications. Having automatic centre/side opening stainless steel doors,Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details- 08 stops, 08 openings and entrance and exit at same side and suitable for travel height of 34 meter approximate. (Shaft Size 2400mm (width)x 3600mm (depth)) with door opening of 1200 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/ Code and complete in all respects as per technical specifications. Test reports from NABL accredited testing labs for all constituent compounds shall be produced.

2

-

-

... More
26Passenger cum Bed Lift-Design, fabrication, supply. installation, testing and commissioning of 26 Passenger cum Bed Lift – Gear less with Machine Room, Capacity / Weight 26 Pass (1768 Kg), Speed 1.5 MPS, electric traction type, Stainless steel (Includig freight & landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with prerecorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. PMSM traction motor ( having efficiency equivalent to IE3 or better as in IS 12615) of machine room elevator shall be of gearless type and placed inside the machine room complete as per technical specifications. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details- 08 stops, 08 openings and entrance and exit at same side and suitable for travel height of 34 meter approximate. (Shaft Size 2450mm (width)x 3600mm (depth)) with door opening of 1200 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/ Code and complete in all respects as per technical specifications. Test reports from NABL accredited testing labs for all constituent compounds shall be produced.

2

-

-

... More
GOODS CUM BED LIFT

-

-

-

... More
2T Goods cum Bed Lift-Design, fabrication, supply. installation, testing and commissioning of electric traction type, with machine room type , Stainless steel, 2T capacity goods cum bed Hospital elevator (Including freight & landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1 Mtr/sec, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons,overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor (having efficiency equivalent to IE3 or better as in IS 12615) of machine room elevator shall be of gear less type and placed inside the machine room complete as per technical specifications. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details -07 stops, 07 openings and entrance & exit at same side and suitable for travel height of 30 meter approximate. (Shaft Size 2500mm (width) x 3000mm (depth)) with door opening of 1500 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/Code and complete in all respects as per technical specifications. Test reports from NABL accredited testing labs for all constituent components shall be produced.

2

-

-

... More
Medical Gas Pipeline System

-

-

-

... More
SITC of Oxygen Manifold - 2 banks x 14 cylinders

1

-

-

... More
SITC of Fully Automatic Oxygen Control Panel with minimum flow rate of 2000 LPM - Imported

1

-

-

... More
SITC of Emergency Oxygen Manifold - 2 banks x 6 cylinders

1

-

-

... More
SITC of Oxygen Flowmeters with humidifier bottle

200

-

-

... More
SITC of Nitrous Oxide Manifold - 2 banks x 2 cylinders

1

-

-

... More
SITC of Fully automatic Gas Control Panel for Nitrous Oxide with a minimum flow rate of 500 LPM

1

-

-

... More
SITC of Emergency Nitrous Oxide Manifold - 1 bank x 1 cylinders

1

-

-

... More
SITC of Carbon Dioxide Manifold - 2 banks x 2 cylinders

1

-

-

... More
od188077/2023_2024 : SITC of Fully automatic Gas Control Panel for Carbon Di Oxide with minimum flow rate of 500 LPM<br>

1

-

-

... More
SITC of Emergency Carbon Dioxide Manifold - 1 bank x 1cylinders

1

-

-

... More
SITC of Duplex Compressed air plant system each compressor having minimum free air delivery of 2000 LPM with complete accessories as mentioned in technical specifications.(Imported)

1

-

-

... More
SITC of Duplex vacuum plant system each pump having minimum free air aspirated of 2000 LPM at 450 mmHg with complete accessories as mentioned in technical specifications. (Imported)

1

-

-

... More
SITC of Ward Vacuum Units

200

-

-

... More
SITC of Theatre Vacuum Units

7

-

-

... More
SITC of ICU Terminal Units - Imported - O2

154

-

-

... More
SITC of ICU Terminal Units - Imported - Air

77

-

-

... More
SITC of ICU Terminal Units - Imported - VAC

154

-

-

... More
SITC of Ward Terminal Units - Indigenous - O2

176

-

-

... More
SITC of Ward Terminal Units - Indigenous - N2O

2

-

-

... More
SITC of Ward Terminal Units - Indigenous - Air

2

-

-

... More
SITC of Ward Terminal Units - Indigenous - Air 7 bar

2

-

-

... More
SITC of Ward Terminal Units - Indigenous - Vac

176

-

-

... More
SITC of Matching Probe - O2

330

-

-

... More
SITC of Matching Probe - N2O

2

-

-

... More
SITC of Matching Probe - Air

79

-

-

... More
SITC of Matching Probe - Air 7 bar

2

-

-

... More
SITC of Matching Probe - VAC

330

-

-

... More
SITC of Master Plant Alarm Panel (post source), BMS compatible,

1

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 6 Services

7

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 4 Services

8

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 2 Services

12

-

-

... More
SITC of Copper pipe - per mtr. - 12mm

1925

-

-

... More
SITC of Copper pipe - per mtr. - 15mm

1928

-

-

... More
SITC of Copper pipe - per mtr. - 22mm

2223

-

-

... More
SITC of Copper pipe - per mtr. - 28mm

609

-

-

... More
SITC of Copper pipe - per mtr. - 35mm

253

-

-

... More
SITC of Copper pipe - per mtr. - 42mm

15

-

-

... More
SITC of Copper pipe - per mtr. - 54mm

235

-

-

... More
SITC of Copper pipe - per mtr. - 76mm

143

-

-

... More
SITC of Ball Valves - 15mm

34

-

-

... More
SITC of Ball Valves - 22mm

30

-

-

... More
SITC of Ball Valves - 28mm

8

-

-

... More
SITC of Ball Valves - 35mm

9

-

-

... More
SITC of Ball Valves - 42mm

2

-

-

... More
SITC of Ball Valves - 54mm

2

-

-

... More
SITC of Ball Valves - 76mm

1

-

-

... More
SITC of Bed Head Units - 1000 mm for Wards

44

-

-

... More
SITC of Bed Head Units - 1500 mm for ICU Category.

66

-

-

... More
SITC of Bed Head Panel - Running Meter

296

-

-

... More
SITC of Rigid Pendent

11

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.