INKEL Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 5,34,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_INKEL_215194_1Bid Award Id
ViewTender No
PMC/2018/01/23 Dated 04-07-2018Tender Authority
INKEL Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing, fabricating and fixing 2 Mtr. high chainlink fencing over 600 mm high random rubble masonry as per design and specification, Chain link fabric mesh of size 50x50mm made of GI wire of dia 4mm chain link with a framework of 50x50x6 mm MS angle between vertical posts of ISMC 75 at 2400 mm interval, which are embedded in cement concrete blocks 45x45x60cm of mix 1:2:4 (1Cement: 2 fine sand: 4 graded stone aggregate 20 mm nominal size) (above GL) with adequate footing depth as per drawing between the RR masonry. RR masonry (450 mm thick) and 600 mm from ground level for foundation and plinth in cement mortar (1:6). The random rubble masonry is to be pointed using cement mortar 1:3 to have a flush finish. One of the fencing frame shall be openable with necessary fittings. 1.5 mtr wide gate shall be provided with suitable locking arrangements. The MS framework for chain link fencing shall be hot dip galvanised. The rate shall be inclusive of all materials, labour, lead, lift, etc.including excavation works and fabrication and assembly works including all nuts, bolts and other miscellaneous items, etc. complete as per drawing and as directed by the Engineer-in-charge at all levels. (Note: All the MS items shall be hot dip galvanised)
130
-
-
Supplying and filling the substation yard with 20 mm size blue jelly of 100 mm thick and 6 mm size blue jelly of 50 mm thick including cost and conveyance of all materials, labour charges etc. complete.
25
-
-
Supplying and erection of galvanised stay set for 11KV over headlines complete with 19/ 20 mm dia X 1.8 metres long stay rod,anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stayclamps, turn buckle ( 20 mm X 600 mm ), 7/ 3.15 mm dia G.I.stay wire and 11 KV stay insulator etc in cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size) foundation including excavation and refilling etc.as required.
12
-
-
Supplying and errection of 11KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
24
-
-
Supplying and erection of 11KV disc insulator for 11KV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
36
-
-
Gang operated, triple pole, 11 KV Air Break Switch mounted on provided channel with adequate length of GI pipe for operating handle erected supported be external bush bearing. The operating handle should be provided with locking arrangement with lock & key at suitable height from ground level with necessary clamp. This should have hot dip galvanized hardware (Corrosion resistance) alignment ofthree arms must be perfect and GOAB operation must be smooth and simultaneous operating hands must be suitable for normal height of operator.
4
-
-
11 KV outdoot type Drop Out Fuse with 11 KV insulator complete with fuse holder fuse barrel with metal fitting fuse element mounted on MS Channel. DO fuse set of three nos of 11 KV should be erected on the provided channel with vertical mounting expansion type and consisting of base plate post insulators, suitable brace terminal connector conforming to IS 5790 / 1970 with all necessary hardware mounting.
4
-
-
11 KV Lightening Arresters with necessary ancillary material , complete erected on provided corss arm and connected to over head line. The lightening arrestors to be provided should be of Thyrite type and suitable for 11 KV supply. The cost included the set of 3 NOS of 11 KV lightening arrestors. The distance between the lightening arrestors should be as per the relevant IS.
4
-
-
Supply of ACSR DOG conductor of size 6/4.72 mm
105
-
-
Erection of ACSR conductor of 7/3.35mm to 7/4.00mm diameter and above including binding etc. as required.
105
-
-
11kV/LT OVER HEAD DISTRIBUTION
-
-
-
Supply,Fabrication, installation, testing and commissioning of A-Type angle iron pole comprising of 2 nos 100x100x8mmx13M height angle iron wleded together after providing 50x50x6mm angle iron spacers/steps of 0.5 m spacing and adquate length on opposite sides. An anticlimbing arrangement should be provided using MS suppoting structure wrapped with layers of barbed wire at height of 3 meter above ground level as anticlimbing arrangement and necessary earthing arrangement including earth wire. Each pole should has an F-clamp on pole top, for accomodating one pin insulator (Note: All the MS items shall be hot dip Galvanised). Number plate should be fixed on every pole or number should be painted. All the components shall be as per the drawing, technical specification and as directed by Engineer-in-Charge at all levels.
54
-
-
Erection of metallic pole of following length in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) RCC foundation including excavation of pits and backfilling etc. as required and as directed by the Engr in charge. (As per the drawing attached); Above 10.00 metre and upto 13.00 metre.
54
-
-
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 3.15 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation including excavation and refilling etc. as required.
30
-
-
Supplying and errection of 11KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
132
-
-
Supplying and erection of 11KV disc insulator for 11KV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
105
-
-
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required. (Note : All the MS item shall be as per the drawing and hot dip galvanised)
68
-
-
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11 kV over head line conductor complete with through nuts and bolts for clamping to the poles, 50 mm X 6mm MS flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins, bolts, nuts, washers etc. (Note : All the MS item shall be as per the drawing and hot dip galvanised)
29
-
-
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/ 33 KV as required.
97
-
-
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required (for Gaurd Wire). (Note : All the MS items shall be hot dip galvanised)
68
-
-
Fitting One Galvanised channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc as required .
68
-
-
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for single wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required. (Note : All the MS items shall be hot dip galvanised)
64
-
-
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
64
-
-
Supply of ACSR RACOON conductor of size 7/4.09mm
5280
-
-
Supply of of ACSR Rabbit conductor of size 7/3.35mm
7040
-
-
Erection of ACSR conductor of 7/3.35mm to 7/4.00mm diameter and above including binding etc. as required.
-
-
-
Supply of of ACSR weasel conductor of size 7/2.59 mm
1760
-
-
Erection of ACSR conductor of 7/2.11mm to 7/3.00mm diameter and above including binding etc. as required.
1760
-
-
Supply of cradle type line guard assembly having 1500mm width, made from GI wires of size not less than 8SWG. The mesh size shall not be more than 500mmx500mm. The cradle shall be confirming to standard engineering practise and IE rule 88.
1600
-
-
Erection of cradle guard as required.
1600
-
-
Supply and erection of LT line tightener for cradling line guard.
400
-
-
Supplying and erection of 100 mm X 80 mm LT pin insulator complete with G. I. Spindle and nuts etc. as required .
176
-
-
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (100 mm X 110 mm), G.I. bolts, nuts and washers, coach screws etc. as required.
140
-
-
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
37
-
-
1X72W LED Street light fitting with LED 72w lamp with driver, greater than 9000 lumens system light output, minimum 5 kV external drive surge protection, THD less than 10% PF greater than .95, with IP 66 protection including all necessary accessories in complete.
37
-
-
Supply all materials and installation of 6A MCB with PVC enclosure including minor civil works
37
-
-
Supply of 11kV Discharge Rod including all accessories required
2
-
-
Supply & Erection of LT line spacers and all accessories required
150
-
-
Supply & Erection of 0 SWG Copper conductor for interconnections.
40
-
-
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with CI/RCC cover plate having suitable lifting hook, watering pipe with charcoal/ coke and salt, marking of pits etc as required as per IS 3043 and as directed by the Engineer in charge.
54
-
-
Supply and installation of channel iron Cradling cross arm 75x40mm GI channel iron cross arms 1.5m length 10.2kg/cross arm with clamp, nuts & bolts, etc in complete. (Note : All the MS items shall be hot dip galvanised)
54
-
-
Supply of 9 Mtr Hot dip galvanised pole for Strut of ISMB 175x85mm on a suitable concrete foundation excluding the cost of foundation
3
-
-
Erection of steel tubular or rail pole strut in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
3
-
-
Supplying and laying of 32mm x 6mm GI Strip on Surface/0.5m below ground level as strip earth electrode, including connection/ terminating with GI nut, bolt spring, washer,etc. as required. (Jointing shall be done by overlapping and with 2 sets of GI nut bolt and spring washer spaced at 50mm).
50
-
-
DOUBLE POLE STRUCTURE
-
-
-
12 Mtr Hot dip galvanised DP Structure :- Fabrication, supply and erection of Hot dip galvanised 11KV/MV DP structure using 200x100 mm ISMB for poles and cross channel of ISMC 100x50mm and 65x65x6mm Channel supporting structure for 11KV components with MS angle cross bracings , supports, on a suitable concrete foundation complete excluding the cost of foundation. The item rate should be inclusive of all required cross-arms for mounting AB switch, etc in complete. All the components shall be as per the drawing and as directed by Engineer-in-Charge at all levels. (Note: All the MS items shall be hot dip galvanised).
2
-
-
Erection of Double pole structure in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation including cement concrete, excavation and refilling etc. as required and secured with holding clamps, bolts, nuts, etc. as required. All types of RCC/PCC Foundation works as per drawing/specification and as directed by Engineer-in-Charge at all levels.
2
-
-
Supplying and erection of galvanised stay set for 11KV over headlines complete with 19/ 20 mm dia X 1.8 metres long stay rod,anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stayclamps, turn buckle ( 20 mm X 600 mm ), 7/ 3.15 mm dia G.I.stay wire and 11 KV stay insulator etc in cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size ) foundation including excavation and refilling etc.as required.
4
-
-
Supplying and errection of 11KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
6
-
-
Supplying and erection of 11KV disc insulator for 11KV overhead lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
12
-
-
Gang operated, triple pole, 11 KV Air Break Switch mounted on provided channel with adequate length of GI pipe for operating handle erected supported be external bush bearing. The operating handle should be provided with locking arrangement with lock & key at suitable height from ground level with necessary clamp. This should have hot dip galvanized hardware (Corrosion resistance) alignment ofthree arms must be perfect and GOAB operation must be smooth and simultaneous operating hands must be suitable for normal height of operator.
2
-
-
DISTRIBUTION TRANSFORMER
-
-
-
S.I.T.C of OUTDOOR type 250kVA, 11/0.433kV oil cooled COPPER WOUND transformer including all accessories. The degree of protection shall be suitable for outdoor application. The transformer shall be designed to suit design temperature of 50deg. The Py voltage shall be varied by OFF LOAD Tap Changer, the tap shall be of +5 to -10% in steps of 2.5%. The primary shall be suitable for connecting 3C x 150Sqmm, 11 kV Al, Armd XLPE cable WITH HT BUSHES and Secondary shall be suitable for 2runs of 3.5Cx185sqmm cable. All standard accessories shall be provided like, name plate with tech details, lifting hooks, jacking pads, breather, bidirectional rollers, winding temperature indicators, relays, alarm and trip contacts etc., Painting shall be carried out as per IS, shade is 631, impedance of the transformer shall be as per IS. The equipment shall satisfy Indian standards, local governing authorities, fire etc., Rate shall be for the complete Transformer with connected civil works including foundation, GI ladder cable tray for cable routing etc. The contractor has to submit vendor's general arrangement, scheme drawings, all other details as per technical specification and approval & manufacturing clearance to be obtained from engineer in-charge.
4
-
-
TRANSFORMER CABLING
-
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor, 11KV grade armored HV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970; 11kV Grade, 3Cx150Sqmm Ar, Al.
60
-
-
Supply, installation, testing and commissioning of Cable End termination with heat shrinkable jointing kit complete with all accessories including lugs for following size XLPE Aluminium conductor cable of 11 KV grade as required; 11 KV (E) grade, 3 core 150 sqmm XLPE cable (Outdoor type).
4
-
-
Supply, installation, testing and commissioning of Cable End termination with heat shrinkable jointing kit complete with all accessories including lugs for following size XLPE Aluminium conductor cable of 11 KV grade as required; 11 KV (E) grade, 3 core 150 sqmm XLPE cable (Indoor type)
4
-
-
Laying of one number XLPE power cable of 11 kV grade of following size direct in ground including excavation,sand cushioning, protective covering with bricks and backfilling the trench etc. as required and as directed by the Engr in charge; Above 120sq.mm and upto 400sq.mm.
60
-
-
Main Boards & Distribution Boards
-
-
-
DISTRIBUTION TRANSFORMER PANEL BOARD
The enclosure shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti-acid & anti corrosive. The manufacturer of board / panel shall be type tested in accordance with IEC61439-2 and shall submit ASTA test report tested at CPRI. The gasket material shall be Polyurethane and shall be internally embedded. Power switchgear and controlgear assembly in accordance with IEC61439-Part 1 and Part 2. As standard main busbar system shall be EMC-complaint, with N/ PEN conductor in the area of phase conductors and with the same current carrying capacity as the phase conductors. For better safety the Polycarbonate enclosure shall be fire retardant & self-extinguishing in accordance with IEC60695-2-1, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960°C. The impact resistance strength of polycarbonate enclosures/ boards i.e. the Degree of Protection against mechanical load IK 08(5 Joule) in accordance with EN50298.
ThemoPlastic Polycarbonate - IP 65 water proof,dust proof,UV resistant,anti acid and anti corrosive, silicon and halogen free power distribution board, seven type tested as per IEC 61439-2 at CPRI with EMC - Complaint copper bus bars rated for 400A, the panel should be with canopy and floor mounting type. MAKE : HENSEL / Rittal.
Incomer
400A FP MCCB - 1 no, Provision for DTR metering for KSEB with necessary protections, RYB indicators - 1 Set.
Out going
160A TPN MCCB - 2 Nos., 125A TPN MCCB - 2 Nos and 63A TPN MCCB - 1 Nos, Provision for DTR metering for KSEB with necessary protections for all outgoings, fully wired as per standards and ready to use.
The contractor has to submit vendor's general arrangement & scheme drawings along with CPRI certificate and approval & manufacturing clearance to be obtained for Engineer in-charge. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits, Clearance & Creepage Distance, Mechanical Operation, etc.
4
-
-
SLDB
Supply installation teting and commissioning OUT DOOR Thermoplastic IP65 4-way FEEDER PILLAR with indication lamps with canopy, suitable steel support for floor mounting etc. including termination for Incoming and outgoing cables and earthing. MAKE : HENSEL / Rittal.
Incomer
63A 4P 16KA MCCB( model no. L&T DN2 250D Cat No.CM 92 108OOL10GOR OR Legrand DPX 125 Cat No. 625328) - 1No., 63A 4P Contactor - 1No. 0-24 Hrs Astronomical Timer- 1No. with bypass arrangement 63A MCCB.
Out going
32A 4P 10KA MCB - 1 Nos, 32A 10KA DPMCB - 3 Nos. 63A 4P Contactor - 1No. 0-24 Hrs Astronomical Timer- 1No. -1 no. The contractor has to submit vendor's general arrangement & scheme drawings along with CPRI certificate and approval & manufacturing clearance to be obtained for Engineer in-charge. The manufacturer of board / panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits, Clearance & Creepage Distance, Mechanical Operation, etc.
4
-
-
CABLING
-
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor. 1.1KV grade armoured. MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970;
3.5C x 185 Sqmm, Ar.Al
96
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor. 1.1KV grade armoured. MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970;
3.5C x 150 Sqmm, Ar.Al
60
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor. 1.1KV grade armoured. MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970;
3.5C x 50 Sqmm, Ar.Al
60
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor. 1.1KV grade armoured. MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970;
2C x 6 Sqmm, Ar.Al
74
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor. 1.1KV grade armoured. MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970;
3Cx2.5 Sqmm Ar, Cu cable.
148
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor. 1.1KV grade armoured. MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970;
2Cx35 Sqmm Ar, Al.
40
-
-
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing mansonry open duct as required;
Above 95 sq. mm and upto 185 sq. mm
40
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required;
Above 95 sq. mm and upto 185 sq. mm
70
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size in the existing RCC/HUME/METAL pipe as erquired;
Upto 35 sq. mm
140
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size in the existing RCC/HUME/METAL pipe as erquired;
Above 95 sq. mm and upto 185 sq. mm
10
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as requires;
Upto 35 sq. mm (clamped with 1mm thick saddle)
68
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as requires;
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
36
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required;
3.5C x 185 Sqmm, Ar.Al
16
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required;
3.5C x 150 Sqmm, Ar.Al
8
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required;
3.5C x 50 Sqmm, Ar.Al
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required;
2C x 6 Sqmm, Ar.Al
37
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required;
3Cx2.5 Sqmm Ar, Cu cable.
74
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required;
2Cx35 Sqmm Ar, Al.
8
-
-
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
8
-
-
Earthing
-
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
4
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Including welding,tinning, fastners etc. Complete
400
-
-
Providing and fixing 50 mm x 6 mm GI strip on surface or in recess for connections etc. as required. Including welding,tinning, fastners etc. Complete
150
-
-
Providing and fixing 75 mm x 10 mm GI strip on surface or in recess for connections etc. as required.
200
-
-
Providing and laying G.I tape 32mmx6mm for earth electrode directly in ground as required.
80
-
-
Earthing with CI Earth plate 1200mmx1200mmx11mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long, etc with charcoal/coke and salt as required.
16
-
-
SOLAR STREET LIGHTS
-
-
-
Single arm Solar Street light :- Supply at site and installation, testing and commissioning of stand alone All-in-one solar LED street light of following specifications;
Luminaire: 45W with output of 7200 lumens.
Solar panel : 250 Wp or suitable for satisfactory operation of the system.
Battery : 1500 Wh, BIS/IEC certified Lithium Ferro Phosphate, Maintenance free battery having minimum 2500 cycles life.
Pole : 7 Meter Octogonl pole, 4mm thickness, GI pole, including all accessories suitable for fitting Solar LED Luminaire.
Luminaire arm / fitting : 1 meter length, GI luminaire arm.
Microwave radar sensor for sensing the motion, externally visible status indicators, 10kV external drive surge protector, IP 65 protection, etc.
The street light should have relevant mechanisms for MPPT charging controller, protections on over charge and deep discharge for batteries, reverse polarity protection for panel and batteries and temperature compensated charging for batteries.
The solar panel must confirm to IEC 61215 standards and battery must confirm to IEC 61427 standards. The vendor should submit LM 79/80 report for light sources from NABL accredited lab.
Make : Crompton/Philips.
30
-
-
Erection of metallic pole of following length in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) RCC foundation including excavation of pits and backfilling etc. as required and as directed by the Engr in charge;
Above 5.0 metre and upto 8.0 metre
30
-
-
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with CI/RCC cover plate having suitable lifting hook, locking arrangement, watering pipe with charcoal/ coke and salt, marking of pits etc as required as per IS 3043 and as directed by the Engineer in charge.
10
-
-
Supplying and laying 10 SWG Copper wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
1200
-
-
CFC YARD, LANDSCAPING & COVERED PARKING AREA LIGHTING
-
-
-
Supply and installation of Smart LED WALL MOUNT with accessories(CROMPTON LBHP-10-CDL / PHILIPS MAKE BWS 150 LED200) with IP65 protection with all accessories in complete.
24
-
-
Supply and installation of LED single tube light fittings of 19 w (Osram Luxpower LED Batten) with extruded aluminium housing and all acessories in complete.
61
-
-
Supply and installation of Smart LED Bollard (CROMPTON LBSLSN-10-CDL / PHILIPS 16463) with all accessories in complete.
40
-
-
Supply and installation of Smart LED SPOT SPIKE (PHILIPS BGP310 3XLED SPIKE SPOT LIGHT) with spike and acessories
6
-
-
MCB DB FOR CFC YARD LIGHTING
-
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer) as required;
8way Double door TPN
3
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
3
-
-
Supplying and fixing following rating, four pole, 415 volts,63A isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
3
-
-
Supplying and fixing 20 amps rating, 240/415 volts, "C" curve, TPN miniature circuit breaker suitable for inductive load
21
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load.
9
-
-
Supply and fixing 32 Amps rating, 240/415V, 4 pole contactor with digital timer switch programmable type with accessories and connections and with metallic enclosure for street light timer control.
21
-
-
CABLING FOR CFC YARD LIGHTING
-
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor. 1.1KV grade armoured. MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970;
3.5Cx35 Sqmm Ar, Al.
100
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, and refilling the trench etc as required, but excluding sand cushioning and protective covering ;
Upto 35 sq. mm.
80
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size in the existing RCC/HUME/METAL pipe as erquired;
Upto 35 sq. mm.
10
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size on wall surface as required;
Upto 35 sq. mm (clamped with 1mm thick saddle).
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required;
3.5Cx35 Sqmm Ar, Al.
4
-
-
CFC YARD & TRUCK YARD LIGHT FITTINGS
-
-
-
Supply all materials and installtion of Single arm Standard 9M overall High GI Octagonal street lighting pole, with 1.5m over hung, 400x400x12mm thick base plate, Junction Box suitable for 2nos 4Cx4sqmm, 2nos of 3Cx2.5sqmm cu cable, MCB, cable entry pipe, civil foundation etc.with 75cms 50mm x 8mm thick angle iron with support bracket and acessories fixed at the pole top for fixing light fittings.
33
-
-
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required;
Above 8.0 metre and upto 10.0 metre
33
-
-
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
33
-
-
1X72W LED Street light fitting with LED 72w lamp with driver, greater than 9000 lumens system light output, minimum 5 kV external drive surge protection, THD less than 10% PF greater than .95, with IP 66 protection including all necessary accessories in complete.
33
-
-
Supply all materials and installation of 6A MCB in existing PVC enclosure including minor civil works
33
-
-
Supply all materials and laying of 3 core 2.5 sq.mm Ar. Copper cable with clamps on cable tray / ceiling/ metal duct.
330
-
-
Supply at site 4 core 2.5 sq.mm Ar. Copper cable
510
-
-
Supply at site 4 core 4 sq.mm Ar. Copper cable
900
-
-
Supply all materials and providing end termination of 3cx 2.5, 4x4 and 4c x 16 sq.mm copper cable.
132
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, and refilling the trench etc as required, but excluding sand cushioning and protective covering;
Upto 35 sq. mm
1250
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size in the existing RCC/HUME/METAL pipe as erquired;
Upto 35 sq. mm
60
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size on wall surface as required;
Upto 35 sq. mm (clamped with 1mm thick saddle)
50
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required;
Upto 35 sq. mm (clamped with 1mm thick saddle)
50
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
10
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Including welding,tinning, fastners etc. Complete
300
-
-
Providing and fixing 10SWG copper wire on surface or in recess for loop earthing as required Including welding,tinning, fastners etc. complete.
200
-
-
BIO-GAS PLANT CABLING
-
-
-
Supply installation testing and commissioning of dust and vermine proof wall mounted cubicle type metering board (Outdoor weather proof) fabricated out of 16 SWG CRS and powder coated with canopy, provision for Energy meter with CT including supply and installation of 100 A HRC fuse base with suitable fuse - 3 nos. and neutral link,125 A TPN isolator - 1 No. Panel should confirm to the KSEB and Electrical Inspectorate standards.
1
-
-
Supplying of XLPE insulated, heavy duty, aluminium conductor. 1.1KV grade armoured. MV cable of the following sizes as required, generally conforming to IS:1554/Part-I/1970;
4Cx10 Sqmm Ar, Al.
100
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, and refilling the trench etc as required, but excluding sand cushioning and protective covering;
Upto 35 sq. mm
70
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size in the existing RCC/HUME/METAL pipe as erquired;
Upto 35 sq. mm
10
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size on wall surface as required;
Upto 35 sq. mm (clamped with 1mm thick saddle)
10
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required;
Upto 35 sq. mm (clamped with 1mm thick saddle)
10
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required;
4Cx10 Sqmm Ar, Al.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements