INKEL Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

INKEL Limited - INKEL Tender

Works
Civil And Construction
Civil Works Buildings
Building Construction
Eprocure
Opening Date26 Apr 2023
Closing Date24 May 2023
Tender Amount₹ 1,08,99,30,840 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring, with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap).Note:Truck mounted/Rotary/TMR/Tubewell boring machine shall not be used.1000 mm dia piles

870

-

-

... More
Pile load test - Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Test reports should be submitted as per the IS norms.Single pile upto 325 tonne capacity.Initial test (Test Load 2.5 times the Safe Capacity)

1

-

-

... More
Pile load test - Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Test reports should be submitted as per the IS norms.Single pile upto 260 tonne capacity.Initial test (Test Load 2.5 times the Safe Capacity)

1

-

-

... More
Pile load test - Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Test reports should be submitted as per the IS norms.Single pile upto 115 tonne capacity.Initial test (Test Load 2.5 times the Safe Capacity)

1

-

-

... More
Pile load test - Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Test reports should be submitted as per the IS norms.Single pile upto 325 tonne capacity.Routine test (Test Load 1.5 times the Safe Capacity)

2

-

-

... More
Pile load test - Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Test reports should be submitted as per the IS norms.Single pile upto 260 tonne capacity.Routine test (Test Load 1.5 times the Safe Capacity)

2

-

-

... More
Pile load test - Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Test reports should be submitted as per the IS norms.Single pile upto 115 tonne capacity.Routine test (Test Load 1.5 times the Safe Capacity)

1

-

-

... More
Earth Work

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

22837.89

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

500

-

-

... More
2.7.3 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited

100

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

2129.2

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

2200.38

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

10335.91

-

-

... More
Conveying and depositing surplus earth for every additional 1Km lead and part thereof including loading and unloading as directed by Engineer- in-Charge.

10000

-

-

... More
Extra for conveying and depositing surplus earth beyond 50m and upto 1Km including loading and unloading as directed by Engineer- in-Charge.

13000

-

-

... More
Plain cement concrete works

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

562.65

-

-

... More
Reinforced cement concrete and Shuttering work

-

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design)All work upto plinth level

129

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design)All work above plinth level upto floor V level

896.51

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 340 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design).All work upto plinth level

2334.89

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Min cement content is 340kg/cum and no payment shall be made for extra cement).All work above plinth level upto floor V level

8806.36

-

-

... More
Providing M-40 grade concrete instead of M-30 grade BMC/RMC (Note:Minimum cement content shall be 360kg/cum for M-40)

2808.58

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

7649.94

-

-

... More
4.6.1 : Providing and fixing at or near ground level precast cement concrete in kerbs, slabs,edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)

6.72

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

2025.18

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

12767.77

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

23946.14

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

30132.89

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

8641.84

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

1246.98

-

-

... More
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards

4783.47

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

24365.56

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo - Mechanically Treated bars of grade Fe-500D or more

408005.9

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

1873152.22

-

-

... More
Block Work

-

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

5399.3

-

-

... More
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

4728.55

-

-

... More
6.3.2 : Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With Modular bricks

72.55

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

112.17

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

93.94

-

-

... More
Random rubble masonry using available rubble at site in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand)

97.68

-

-

... More
Supplying and packing 20mm stone aggregate between the retaining wall and earth fill along the building perimeter including watering, ramming, consolidating and dressing complete including lead, lift, stacking, transportation etc. as directed by the Engineer in charge - for retaining wall

215.55

-

-

... More
7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)

287.87

-

-

... More
Joinery Works

-

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

2710.87

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

388.08

-

-

... More
Providing and supplying Single glazing comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade(as per specification).

388.08

-

-

... More
25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

28.98

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

9729.83

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

17049.25

-

-

... More
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

654.12

-

-

... More
Providing and fixing 9mm thick heavy duty fiber cement board confirming to IS 14862:2000 with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge.

108

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With toughned glass of 6mm thickness

262.37

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

1153.44

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

586.25

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

275

-

-

... More
21.11.2 : Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm

158

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

300

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

1494

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

535.5

-

-

... More
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

165

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

197

-

-

... More
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm

575

-

-

... More
9.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm

575

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

222

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).

9.6

-

-

... More
Providing and fixing Stainless Steel Corner Patch Lock with Strike Plate of SSS finish for toughened glass door including all necessary fittings Or equivalent.

4

-

-

... More
Providing and fixing Stainless steel D type glass door handle with SSS polished finish of 25mmx450mm size.

4

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

250

-

-

... More
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

275

-

-

... More
9.106.2 : Providing and fixing PTMT handles with necessary screws etc. complete.150x34x24 mm weighing not less than 26 gms

590

-

-

... More
9.108.2 : Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms

590

-

-

... More
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

550

-

-

... More
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm

500

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

415

-

-

... More
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) locking arrangement for sliding windows including necessary screws and fittings of approved make as directed by Engineer-in-charge.

1210

-

-

... More
Providing and fixing roller for shutters of sliding aluminium windows with necessary screws etc.complete.As approved by Engineer-in-charge

4840

-

-

... More
Providing and fixing roller for Aluminium sliding door

200

-

-

... More
Providing and fixing 25mm panel lock (triangular) of required length for duct doors with necessary screws etc.complete.

100

-

-

... More
Providing and fixing aluminium square handle of length 15 to 20 cm for aluminium duct doors with necessary screws etc.complete.

100

-

-

... More
Providing and fixing in position frameless fixed glazing using 12mm toughened glass fitted with patch fittings of approved brand or manufacture as detailed in the draiwng of specified size including supplying and fixng necessary holdfats, screws for fixing cleats, toughened glass with all labour and materials complete as per drawings and as directed.

15.12

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.1500mmX2400mm

3

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 1000mmX2100mm

4

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1200mmX2100mm

17

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1500mmX2400mm

16

-

-

... More
Double Leaf SS 304 Finish Swing Door: Product Description : Size 1500mm (W) 2100 mm (H). with clear opening of 1880 mm x 2340 mm. 44 mm (THK) PUF infil door leaf Component Polyurethane Rigid CFC Free, Blowing Agent: Water. Dimensional stability at +100°C &-25°C (2%max) as per DIN53431. Density 45Kg/M3 with max deviation of 2kg/m3 as per DIN53420. Condensation resistance at 38°C and 88RH Max variation 2% in weight and volume . 0.6 mm SS 304 finish door leaf,double glazed vision panel with 4 mm clear glass (300 mm X 300 mm), Anodized door profile Aluminium Wall frame 80mm x 60mm Al 6063 anodized, 2.5 mm thick with GI reinforcment with conealed dead lock for passive leaf with Locking cylinder,closure, Ball Bearing Hinge 4 nos per leaf, D handle (back to back)- No organic material no decay.

1

-

-

... More
Single Leaf SS 304 Finish Swing Door: Product Description : Size 1000mm (W) 2100 mm (H). with clear opening of 1380 mm x 2340 mm. Passive leaf size 300 mm 44 mm (THK) PUF infill door leaf Component Polyurethane Rigid CFC Free, Blowing Agent: Water. Dimensional stability at +100°C & -25°C (2%max) as per DIN53431. Density 45Kg/M3 with max deviation of 2kg/m3 as per DIN53420.Condensation resistance at 38°C and 88RH Max variation 2% in weight and volume. 0.6 mm SS 304 finish door leaf, double glazed vision panel with 4 mm clear glass (300 mm X 300 mm), Anodized door profile Aluminium Wall frame 80mm x 60mm Al 6063 anodized, 2.5 mm thick with GI reinforcement with concealed dead lock for passive leaf with Locking cylinder, closure, Ball Bearing Hinge 4 nos as per leaf, D handle (back to back)- No organic material no decay.

1

-

-

... More
Frosted film - Supply and installation of 3M make frosted film pattern throughout all the internal glass panels wherever required of approx. 1.5 m height as per the approved pattern.

564.12

-

-

... More
Steel work and Fire Doors

-

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

15519.54

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

2050.9

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

233.64

-

-

... More
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes

23096.46

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

1105.6

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

2421.6

-

-

... More
10.3 : Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer .

6

-

-

... More
10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

106.2

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

20

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

86.4

-

-

... More
10.8.2 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 16.80 sqm in area

19.8

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

35.4

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

7057.98

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m2 . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

238

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately

168

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge. The glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments).

6.3

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

70

-

-

... More
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm

140

-

-

... More
Flooring and Waterproofing

-

-

-

... More
16.75 : Providing and laying C.C pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge ( The panel shuttering work shall be paid for separately)

76.33

-

-

... More
13.52.2 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work

1696.04

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

19348.99

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

237.46

-

-

... More
Providing and fixing I st quality ceramic glazed wall tiles of size 600x600 conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

19526.4

-

-

... More
Providing and laying Vitrified step tiles in single piece indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.

520.66

-

-

... More
Extra for using or fixing glazed/ Ceramic/ Vitrified wall tiles with cement based high polymer modified quick-set tile adhesive ( Water based) conforming to IS : 15477, in average 3 mm thickness.

19526.4

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all completas per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

1531.27

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

253.89

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

100

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

2517.45

-

-

... More
Grading roof for water proofing treatment with:12mm thick plastering in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and mixing with water proofing material in proportion recommended by the manufacturers

2624.47

-

-

... More
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer in- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

3361.02

-

-

... More
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer in- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

1764.53

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

1883.74

-

-

... More
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate

669.87

-

-

... More
False ceiling works and Expansion Joint

-

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending

6803.36

-

-

... More
12.52.2 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.

10674.14

-

-

... More
Aluminium Non perforated false ceiling - Providing & Fixing true horizontal level swing down suspended ceiling comprising of approved make Aluminum Clip in Swing Down with double pip self-leveling feature and special tabs to allow swing down of tile to enable plenum access with plain visual consisting of 600X600 mm clip in plain tiles of 0.7mm uniform thickness Aluminum with bevel edge in approved color precoated with primer coat at the rear side with Light Reflectance 60%.Tiles should have fire performance of Class A2-s1.d0 as per EN13501.The grade of aluminiumshall mandatorily be AA 3003. The AluminiumTile shall mandatorily be RoHS Compliant (Resistance of Hazardous Substance).Compliant certificate shall be provided on demand. The tile shall maintain uniform Thickness of 0.7mm across all areas of tiles with no deviation. The tile shall have paint thickness of 25 microns to enable better scratch resistance.The tile shall have the ability to combine the main light with extra illumination providing 77% light reflectance & enables to achieve light uniformity. The tile shall have g Ceiling Attenuation Class of 44db. It shall withstands upto 150 Scrub cycle using Scrubablity tester as per ASTM D 2486. The tile shall offer superior wash performance without compromising panel finish integrity using a washablity tester as per ASTM D 4828. Installation: To comprise 3000mm long 'C' channels spaced at 1200mm centers securely fixed to the structural soffit by support clamp & approved hangers. The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm spring tee bars shall be spaced at 600mm centers in a direction perpendicular to the C-channels and shall be secured at every intersection with C channel using a tee bar hanger. Use T bar connector to splice two pieces of spring tee bars. Tiles should be clipped in between two spring tee bars from below. This is a downward installation. All full panels can be removed and reinstalled without movement up into the plenum area. Perimeter trims of approved color secured to walls at 450mm maximum centers. Cut tiles to be secured to the wall angles using a spring clamp. The installation shall be undertaken as per the manufacturer's installation instructions and as directed by the Engineer-in-Charge.

1897.67

-

-

... More
Finishes

-

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

10325.19

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

73083.45

-

-

... More
Wall painting with acrylic emulsion paint(low VOC paint as per Griha norms V-2015) of approved brand and manufacture to give an even shade:Two or more coats on new work

50756.7

-

-

... More
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).

20812.97

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

61.63

-

-

... More
4.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)

116.65

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

64129.69

-

-

... More
13.5.1 : 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1 Cement : 4 coarse sand)

1121.69

-

-

... More
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

1166.43

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

14515.22

-

-

... More
Finishing walls with textured exterior paint (low VOC paint as per Griha norms V-2015) of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

2465.41

-

-

... More
Finishing walls with Acrylic Smooth exterior paint (low VOC paint as per Griha norms V-2015) of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

22188.54

-

-

... More
12.63 : Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittnce tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strictly as per manufacture's specifications and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer - in- charge.

1850.31

-

-

... More
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

500.38

-

-

... More
60.6 : PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.

364.73

-

-

... More
Finishing and Roofing

-

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

929

-

-

... More
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2

72.95

-

-

... More
Poly carbonate sheet roofing -Supply and installation of 2mm thick Poly-carbonate sheet roofing of approved make, embossed clear with UV protection coating/treatment and weight not less than 2400gms/ sqm. It shall be fire retardant and confirming to IS 14443. the rate shall include aluminium leak proofing and fixing management system with EPDM rubber gaskets, silicone sealant etc. complete as required and as per the direction of engineer in charge

180.66

-

-

... More
External Works

-

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

7

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

9

-

-

... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

3

-

-

... More
2.33.4 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth

2

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

500

-

-

... More
19.35.1 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportioof 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.

60

-

-

... More
19.35.2 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.600 mm dia RCC pipes.

25

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

1269.89

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-40 grade with approved color design and pattern.

5500.73

-

-

... More
16.90 : Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

241.4

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

21.37

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

209.6

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

10

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

50

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

10

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

30

-

-

... More
Site clearance

-

-

-

... More
Clearing and grubbing land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 200 mm in thickness In area of thorny jungle - By Mechanical Means

0.93

-

-

... More
Public Health Engineering (PHE) System Sanitary Fixtures

-

-

-

... More
Providing and fixing White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF Dual Cistern, overall size 765 x 370 x 650mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion/ rawl sleeves, gasket etc. complete, and fixing to wall, as per manufacturer's instruction and to the approval of Engineer-in-charge.

189

-

-

... More
Providing and fixing sanitary fixtures for handicapped toilet including one number Extended wall mount closet with soft close seat cover and cistern one wash basin, one pair mounting brackets,one number elbow operated pillar cock and all other related fittings like waste coupling one number hinged rail 76 cm & 4 nos. of grab rails 60cm etc designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge.

4

-

-

... More
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

4

-

-

... More
17.80 : Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge.

56

-

-

... More
8.10.2 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade

28

-

-

... More
Providing and fixing White Vitreous China Counter Top / Bottom Wash Basin, 400 x 550 mm or equal,compatible for a washing rate of 6 LPM or less, including 32mm. CP Waste Coupling, C.P. Brass Chain with rubber plug, and fixing to counter with suitable fixtures, all as per manufacturer's instruction and the direction of Engineer-in-charge.

129

-

-

... More
Providing and fixing White Vitreous China Wall Hung Wash basin, 550 x 400 mm or equal, including 32mm. CP Waste Coupling, C.P. Brass Chain with rubber plug, and fixing to counter with suitable fixtures, all as per manufacturer's instruction and the direction of Engineer-in-charge.

74

-

-

... More
Providing and fixing , 15mm. CP Pillar Tap, Self Closing Type with Pre Set time 5 to 6 Sec, with a controlled flow rate of 2.5 LPM at 3 Bar.(overall dimensions:110 x 120 /150mm. or equal ), complete with all necessary accessories for Domestic Wash Basins, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

203

-

-

... More
17.25.6 : Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:Surgeon type wash basin of 660x460 mm

44

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action Pillar Tap with extended lever handle, flow rate of 3.8 LPM at 3 Bar, complete with all necessary accessories for Wash Basins in Doctors / Treatment Rooms, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

44

-

-

... More
17.11.2 : Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm

68

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

3

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action, Wall Mounted type,Clinical Sink Tap with extended lever handle, flow rate of 3.8 LPM @ 3 Bar, complete with Wall Flange and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

53

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action, Wall Mounted type,Clinical Sink Mixer with extended lever handle, flow rate of 3.8 LPM @ 3 Bar, complete with Wall Flanges and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

18

-

-

... More
Providing and fixing CP Shower Set, Hot & cold CP aerator wall mixer unit with long bend pipe for overhead shower with all accessories including Head Shower, Shower Arm, etc.,including all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

36

-

-

... More
Providing and fixing CP Shower Set, for Cold Water only, low flow rate of 6 LPM or less, Commercial Range, complete with Concealed Valve & Exposed Control Unit, Head Shower,Shower Arm, etc., including all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

62

-

-

... More
Providing and fixing CP Long Body Tap, both Cold & Hot Water Supply, with a controlled flow rate of 6 LPM @ 3 Bar, 15mm. nominal bore, 185mm. long with wall flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

85

-

-

... More
Providing and fixing Health Faucet with a controlled flow rate of 3.8 LPM @ 3Bar, 15mm. CP Braided Hose, Hook and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

193

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

625

-

-

... More
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore

432

-

-

... More
Providing and Fixing ABS Body P-Trap with threaded union connections, flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge. For Wash Basin, 32mm, Size.

247

-

-

... More
Providing and Fixing ABS Body P-Trap with threaded union connections, flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge. For Clinical Sinks and Scrub, 40mm, Size

71

-

-

... More
Supplying, installing, testing & commissioning at site in position Grab Bar up to 600mm complete.

189

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

98

-

-

... More
17.72 : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms

112

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

98

-

-

... More
17.34.1 : Providing and fixing toilet paper holder:C.P. brass

4

-

-

... More
C. P. Robe Hook,60mm. Dia. x 45mm. High.

197

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

203

-

-

... More
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

112

-

-

... More
Internal Drainage

-

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal). 160mm OD

6

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm),Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal). 110mm OD

1920

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm),Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal). 75mm OD

1765

-

-

... More
50.18.9.17.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall

313

-

-

... More
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall

479

-

-

... More
50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall

50

-

-

... More
50.18.9.14.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall

162

-

-

... More
50.18.8.7.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2

311

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

319

-

-

... More
50.18.8.5.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2

50

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type A(IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm),Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Vent pipes -Internal). 75mm OD

25

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of 4kg/cm2 (IS:4985)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends,Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Vent pipes -Internal). 63mm OD

558

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 160mm OD" -Internal). 160mm OD

10

-

-

... More
"Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 110mm OD

1100

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 75mm OD"

504

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 160mm OD"

204

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 110mm OD

672

-

-

... More
"Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 75mm OD

530

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe of 4kg/cm2 (IS:4985)including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete. 63 mm OD(4kg/cm2)

252

-

-

... More
Deep Seal uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position Deep Seal (7”) uPVC Fabricated Multi Floor Trap, with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, Anchor fasteners etc. complete in all respects - 50/75 mm dia inlet/outlet (In Ceiling)

335

-

-

... More
uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost of cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken)

100

-

-

... More
Supplying, installing, testing & commissioning at site in position 110mm dia deep seal PVC P Trap with boss tee and access cap including all necessary fittings and supports complete.

20

-

-

... More
C.P. cast brass or stainless steel Square Flat cut lock anti cockroach grating cover - Providing and Fixing Heavy Duty Stainless Steel Square Flat cut lock anti Cockroach Trap Stainless Steel A ISI 304 with 125x125 mm. Grating, for 110mm. Floor Traps.

460

-

-

... More
Heavyduty stainless steel cover for Concealed Floor Trap for Urinal - Providing and Fixing 125x125mm dia Heavyduty stainless steel cover for Concealed Floor Trap ISI 304 Cover, for Urinal.

20

-

-

... More
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 110mm

10

-

-

... More
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 75mm

10

-

-

... More
17.35.1.3 : Providing and fixing soil, waste and vent pipes:100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

130

-

-

... More
17.38.1.3 : Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm diaHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

25

-

-

... More
17.39.1.3 : Providing and fixing plain bend of required degree.100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

8

-

-

... More
17.42.1.3 : Providing and fixing double equal plain junction of required degree.100x100x100x100 mmHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

3

-

-

... More
17.44.1.3 : Providing and fixing single equal plain junction of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

5

-

-

... More
17.49.1.3 : Providing and fixing double equal plain invert branch of required degree:100x100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

2

-

-

... More
17.50.1.3 : Providing and fixing single equal plain invert branch of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

8

-

-

... More
17.56.1.3 : Providing and fixing terminal guard:100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

1

-

-

... More
17.60.1.3 : Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outletHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

10

-

-

... More
17.57A.1.1 : Providing and fixing shielded coupling for Hubless centrifugally cast iron pipeSS 304 grade coupling with EPDM rubber gasket

100

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Dome Type with Cast Iron body,Aluminium Ring, Aluminium Dome, S.S. Screws etc. complete with Gratings, suitable for 110mm. of down pipes. 100mm dia. for 110mm. PVC Down Pipe

14

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Dome Type with Cast Iron body,Aluminium Ring, Aluminium Dome, S.S. Screws etc. complete with Gratings, suitable for 160mm. of down pipes. 150mm dia. for 160mm. PVC Down Pipe

5

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Side Wall Parapet Type in Cast Iron body,Aluminium Gratings, S.S. Screws etc. complete with Gratings, all as per Technical Specifications. 100mm dia. for 110mm. PVC Down Pipe

3

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Side Wall Parapet Type in Cast Iron body,Aluminium Gratings, S.S. Screws etc. complete with Gratings, all as per Technical Specifications. 150mm dia. for 160mm. PVC Down Pipe

1

-

-

... More
Water Supply

-

-

-

... More
18.8.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes

442

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

2776

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

25

-

-

... More
18.7.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15 mm nominal outer dia pipes

653

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

3756

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

864

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

462

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

125

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

236

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 65 mm nominal outer dia pipes

566

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 80 mm nominal outer dia pipes

50

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 20 mm nominal outer dia. Pipes.

854

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 25 mm nominal outer dia. Pipes.

275

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 32 mm nominal outer dia. Pipes.

354

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 40 mm nominal outer dia. Pipes.

190

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 50 mm nominal outer dia. Pipes.

460

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes.

360

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 80 mm nominal outer dia. Pipes.

580

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 100 mm nominal outer dia. Pipes.

35

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 100 mm nominal outer dia. Pipes.

70

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes.

70

-

-

... More
18.18.1 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:15 mm nominal bore

24

-

-

... More
18.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

431

-

-

... More
18.18.3 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore

23

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

30

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

10

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

10

-

-

... More
Supply, fix at site in position, test and commission, Forged Brass Ball Valves to IS: 554 / BS:21 / ISO: 7,PN;25, with Screwed Female Ends complete with all necessary accessories.40mm. (11/2")

4

-

-

... More
Supply, fix at site in position, test and commission, Forged Brass Ball Valves to IS: 554 / BS:21 / ISO: 7,PN:25, with Screwed Female Ends complete with all necessary accessories. 50mm. (2")

3

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN;25, Screwed Female ends, complete with all necessary accessories. 15mm. (1/2")

66

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN;25, Screwed Female ends, complete with all necessary accessories. 20mm. (3/4")

66

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN;25, Screwed Female ends, complete with all necessary accessories. 25mm. (1")

6

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN;25, Screwed Female ends, complete with all necessary accessories.32mm. (11/4")

9

-

-

... More
18.19.2.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end): 32 mm nominal boreHorizontal

2

-

-

... More
18.19.3.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreVertical

2

-

-

... More
18.19.4.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreVertical

2

-

-

... More
18.19.5.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end): 65 mm nominal boreVertical

14

-

-

... More
Providing and fixing Brass non-return valve of approved quality (screwed end):100 mm nominal bore Vertical

2

-

-

... More
Brass Automatic Air Release Valves - Providing, Fixing, testing and commissioning at site in positions Brass Automatic Air Release Valves, of approved quality and make on the top of the vertical water supply pipes as per specification and drawing - 3/4"(20mm) dia

70

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN 6) of approved make with PP float & nipple with brass threaded add, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 65mm dia (21/2”)

1

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN6) of approved make with PP float & nipple with brass threaded add, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 50mm dia (2”)

1

-

-

... More
SS ball valve 15mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - ½” (15mm) dia

4

-

-

... More
SS ball valve 20mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - ¾” (20mm) dia

45

-

-

... More
SS ball valve 25mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1” (25mm) dia

18

-

-

... More
SS ball valve 32mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve(screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings.- 1¼”(32mm) dia

6

-

-

... More
SS ball valve 40mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1½”(40mm) dia

2

-

-

... More
SS ball valve 50mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve(screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 2”(50mm) dia

1

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

2

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

4

-

-

... More
Providing and fixing C.I. Sluice Valve, PN-16, with IS: 14846 Mark, with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. 80mm PN-16

1

-

-

... More
Providing and fixing C.I. Sluice Valve, PN-10, with IS: 14846 Mark, with required flanges, rubber insertion , bolts, nuts, Washers etc. complete. 300mm PN-10

2

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect.80 mm dia

6

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect.100 mm dia

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum.Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10 meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection Output is compactable for SMART meters as per GRIHA Certification requirements. Water meter 40mm

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius &performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum.Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10 meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection Output is compactable for SMART meters as per GRIHA Certification requirements. Water meter 50mm

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum.Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10 meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection Output is compactable for SMART meters as per GRIHA Certification requirements. Water meter 65mm

3

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius &performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum.Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10 meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection Output is compactable for SMART meters as per GRIHA Certification requirements. Water meter 80mm

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum. Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10 meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection Output is compactable for SMART meters as per GRIHA Certification requirements. Water meter 100mm"

1

-

-

... More
Supplying, fixing testing and commissioning Stainless steel Butterfly Valve Grade 316(CF8M), PN-16,Wafer type, Lever Operated, Confirming to BIS: 5155 / IS 13095 / API 609, with required flanges, nuts,bolts etc., complete 65 mm dia

5

-

-

... More
Supplying, fixing testing and commissioning Stainless steel Butterfly Valve Grade 316(CF8M), PN-16,Wafer type, Lever Operated, Confirming to BIS: 5155 / IS 13095 / API 609, with required flanges, nuts,bolts etc., complete 80 mm dia

1

-

-

... More
CI Y Strainer 1 ¼” (32mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects.

2

-

-

... More
CI Y Strainer 1 ½” (40mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects.

1

-

-

... More
CI Y Strainer 2” (50mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects.

1

-

-

... More
CI Y Strainer 2 ½” (65mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects.

2

-

-

... More
CI Y Strainer 3” (80mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects -

2

-

-

... More
CI Y Strainer 4” (100mm) dia - Supply, Installation, Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects -

3

-

-

... More
"Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 100 mm. dia. (4") pipe."

15

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 80 mm. dia. (3") pipe"

330

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 65 mm. dia. (21/2") pipe."

760

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 50 mm. dia. (2") pipe.

350

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 40 mm. dia. (11/2") pipe."

48

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 32 mm. dia. (11/4") pipe.

24

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastrometric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 25 mm. dia. (1") pipe."

24

-

-

... More
"Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 20 mm. dia. (3/4") pipe."

24

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 65mm. (2 1/2") pipe.

12

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 50mm. (2") pipe.

43

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 40mm. (1 1/2") pipe.

55

-

-

... More
"Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 32mm. (1 1/4") pipe."

151

-

-

... More
"Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 25mm. (1") pipe.

234

-

-

... More
"Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 20mm. (3/4") pipe."

228

-

-

... More
"Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 15mm. (1/2") pipe.

234

-

-

... More
Valves (E&M)

-

-

-

... More
16.11.1.6 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 65 mm dia

18

-

-

... More
16.11.1.5 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 80 mm dia

18

-

-

... More
16.11.1.4 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 100 mm dia

6

-

-

... More
16.11.1.2 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) of 150 mm dia

1

-

-

... More
External Sewerage and Storm Water Drain

-

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 200mm OD

42

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 160mm OD

1009

-

-

... More
"Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 110mm OD

254

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying,Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 75mm OD"

125

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients,PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 315mm OD

90

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients,PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 250mm OD

143

-

-

... More
"Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 200mm OD"

90

-

-

... More
"Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation) 160mm OD"

50

-

-

... More
"Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation) 110mm OD"

30

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings,This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 65 mm nominal outer dia Pipes"

150

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2466) Fittings,This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 80 mm nominal outer dia Pipes"

20

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2466) Fittings,This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 100 mm nominal outer dia Pipes"

80

-

-

... More
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. 90 mm dia 10 kgf/cm2

1041

-

-

... More
Supply,installation, testing and commissioning of stainless steel coarse Screen (opening 10mm) suitable for screen chamber of size 500mmx500mm removable type including all material charges,labour transportation,loading unloading etc. Complete as per the direction of Engineer in charge

6

-

-

... More
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With Sewer bricks conforming to IS: 4885

41

-

-

... More
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design

400

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

1833

-

-

... More
Extra for excavating trenches for pipes above 80mm. But not exceeding 300mm.. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre). Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

90

-

-

... More
18.41.1A : Providing and filling sand of grading zone V or coarser grade, all - round the G.I. pipes in external workSub analysis item for sand filling component

115

-

-

... More
4.1.10 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

122

-

-

... More
Supply, installation, testing and commissioning at site Rain Water Filter Unit, Bag Filtration System,suitable for a Flow Rate of 135M³/ Hr, with Filter Bags and Accessories in FRP Fabricated Tank,1500mm. dia. x 1500mm.deep. Wall thickness 10mm. all as per Technical Specifications. The price is inclusive of connected Pipe Work. Civil work is to be counted separately.

1

-

-

... More
Civil Work for RCC Manhole

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

337.5

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

52.28

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

38.91

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

56.27

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

76.47

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

5627

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

422.5

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

315

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

4856

-

-

... More
Miscellaneous Items

-

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 160mm dia.

4

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 110mm dia.

642

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 75mm dia.

6

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 63mm dia.

62

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 50mm dia.

112

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 40mm dia.

10

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 32mm dia.

175

-

-

... More
600 X 600 mm (24" X 24") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Light Duty (5 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124. For OH Water tank

6

-

-

... More
600 X 900 mm (24" X 36") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Heavy Duty (25 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124. For UG Sump

8

-

-

... More
600 X 600 mm (24" X 24") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover with frame Heavy Duty (25 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124. For UG Sump

16

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 150mm (6")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 150mm(6") uPVC Astm Sch 80 Puddle flange

1

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 100mm (4")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -100mm(4") uPVC Astm Sch 80 Puddle flange

8

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 80mm (3")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 80mm(3") uPVC Astm Sch 80 Puddle flange

6

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 65mm (2½") uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -65mm (2½") uPVC Astm Sch 80 Puddle flange

16

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 50mm (2")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 50mm(2") uPVC Astm Sch 80 Puddle flange

3

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 40mm (1½")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 40mm (1½")uPVC Astm Sch 80 Puddle flange

2

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 32mm (1¼")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -32mm 1¼"uPVC Astm Sch 80 Puddle flange

1

-

-

... More
Plumbing Pumps and Heat Pumps

-

-

-

... More
Vertical multi stage centrifugal pumps (surface pump) for Domestic Water Supply - Supply, Installation,Testing and Commissioning 2 nos, Vertical multi stage centrifugal pumps (surface pump) set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 12 lps @ 60 mtr head, Head range 40 to 75 mtrs (14.5 lps to 7.08 lps), ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection, Hydraulic efficiency more than 67% motor efficiency more than 85% with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) Star Delta,having features of automatic pump change over in every Start/Stop, Dry run,Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function, Digital display,Pressure gauge, Float Switches, Auto/Manuel Operation. The price is inclusive of all connected electrical work.

1

-

-

... More
"Vertical multi stage centrifugal pumps (surface pump) for Flush Water Supply - Supply, Installation,Testing and Commissioning 2 nos, Vertical multi stage centrifugal pumps (surface pump) set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 5 lps @ 60 mtr head, Head range 48 to 80 mtrs (6.1 lps to 2.2 lps), ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection, Hydraulic efficiency more than 67% motor efficiency more than 85% with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) Star Delta,having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function, Digital display,Pressure gauge, Float Switches, Auto/Manuel Operation. The price is inclusive of all connected electrical work"

1

-

-

... More
SEWAGE & WASTE WATER TRANSFER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Cutter Pumps with IE3 Rated Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete as per Tender Drawings and Tender / Technical Specifications Cable length all Cutter Pumps shall be 10 Mtr. Minimum Capacity: 5LPS @ 20 Mtr. Head, 3Ph, Complete Set.

3

-

-

... More
SEWAGE & WASTE WATER TRANSFER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Cutter Pumps with IE3 Rated Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete as per Tender Drawings and Tender / Technical Specifications Cable length all Cutter Pumps shall be 10 Mtr. Minimum Capacity: 5.5LPS @ 20 Mtr. Head, 3Ph, Complete Set.

3

-

-

... More
"FILTER FEED PUMP SET. Supply, Testing and Commission Filter Feed Pump Set, Submersible Type for Pumping Raw Water to Water Treatment Plant, 2 Pump System with One Working + 1 One Cyclically Stand by Pumps, each Pump of Capacity: 20M³/Hr. @ 45Mtr. Head, having SS Impeller, Shafts, Casing, with 3Ph, complete with Microprocessor Based Control Panel, for Auto and Cyclic Operation, with all Protection (Digital display, Low &high voltage protection, dry run, phase reversal,pump over load, etc.), Level Sensors / Float Switches in Treated Water & Raw Water Tanks and Control Cabling / Wiring between Level Sensors / Float Switches and Control Panel, Delivery Manifold, Isolating Valves, Non Return valves, Pressure Gauge, Fittings, Stainless Steel (Grade:304) Lifting Chains,Accessories etc. all as per Technical Specifications. The Control Panel shall be capable operating the pumps (starts and stops) by sensing the level difference in water in the Treated Water Tank. Also; capable of ‘not starting or stopping the running pumps', when the water in the underground Raw Water Tank goes below the pre-set minimum level. The Pumps to be installed in the Underground Raw Water Tank and Common Control Panel in the Pump Room, in Basement Floor, approx. 100 Mtr. away from Raw Water Tank. The Underground Power Cabling between Pumps and Control Panel and Control Cabling between Control Panel & Level Sensor / Float Switch, in the Underground Raw Water Tank, shall be measured as a part of Electrical Work. The Quoted Price for the Pump Set shall be inclusive of all above requirement, necessary Level Sensors / Float Switches, Power Cabling, Control Cabling etc, except what measured as a part of Electrical Work, as detailed above.

1

-

-

... More
Supply, Testing and Commission Submersible Type Storm Water Transfer Dewatering Pump Set,complete set with 1 working + 1 Standby Submersible non- clog pump , Solids handling: 40mm , and with Common Control Panel for automatic operation and Manually change over facility. Capacity 12 M3/Hr. at 10 Mtrs. head, each, with Three Phase with float switches/level sensors etc. necessary control valves, Pressure Gauges fittings and accessories, for discharging rain water from collection pits in basement floor, to lower strata. The price shall inclusive of all connected electrical work as detailed in the technical specification.

1

-

-

... More
"Supplying, Installing, Testing & Commissioning at site hot water recirculation pump with suitable pressure switch, dry run protection & The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication( Modbus). Type : Thermostatic Controlled. Horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The shaft, impellers and chambers are made of stainless steel. The inlet and discharge parts are made of cast iron. It’s supporting up to 95 degree Celsius temperature, digital control panel with Time and Temperature settings facility. Flow for each pump in LPS : 2.3 Head in mtr : 14 Head Range : 8 - 16 mtr MOC : SS 304 Impeller Total no of pump: 1 SET ( 1Working + 1Standby )"

1

-

-

... More
Supply, installation, testing & commissioning of Solar assisted Heat pump, insulated pressurised SS storage tank, hot water expansion vessel, insulated piping between the system, valves & accessories required to complete the system in position with the following specification. 10,000 LPD, consisting of Solar Hot Water Panels of Aggregate Capacity: 5,000 LPD (50% of the total requirement), 58 Deg C required Insulated Hot Water Storage Tank suitable for 6 bar pressure SS 316 - 1no, 5000 Litre - Horizontal. COP of Heat pump 4 Circulation Pump between heat pump and storage tank, including control panel. Plumbing work Between storage tank and heat pump CPVC Pipe with suitable CPVC Fittings. Suitable Brass Fittings like NRV, Y Strainer, Air Vent, MTA, FTA, Flow Switches, Pipeline Insulation Electrical Work From Pump panel to heat pump 6 Square MM 4 core cable, 1.5 Square MM 3 core cable, 2.5 Square MM cable, Communication cable, 3 x 9Amps 3MP Contactors Coil Operated, PVC conduits for cables with suitable fittings etc., complete.

1

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

5000

-

-

... More
Water Treatment Plant

-

-

-

... More
Supply, Installation, testing and commission Water Pre-Treatment Plant Capacity: 20M3 /Hr, for continuous operation of 10 Hr, complete with High Pressure Sand Filter, Activated Carbon Filter,with Multiport valves, Chemical Dosing etc as per final requirement, connected Pipe Work etc, all as per Technical Specifications.Filter Feed Pumps shall be measured seperately.

1

-

-

... More
Sewage Treatment Plant

-

-

-

... More
Supply, installation, testing, commissioning and operation of Sewage Treatment Plant Electro -Mechanical Work, Capacity: 200KLD, as per KSPCB norms all as per the detailed specification

1

-

-

... More
HT & LT Electrical System Works HT Works

-

-

-

... More
RMU Design, Fabrication, Supply, Installation Testing and Commissioning of 11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated,Ring Main Unit outdoor type with 2 nos motorized Load Break Switch as incomer and 1 no. motorized Non drawout type VCB (fully rated earth switch) , 630 Amp continously rated Cu busbar complete with all accessories, protective relays, indicators, Hooter ,battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale,provision for padlocking for open, close, earth and test position etc. on a suitable foundation. The RMU must be both side extensible type and compatible for SCADA system.The rate quoted shall be inclusive of hoisting to its location,assembling of units,lining up, bolting the units and checking all control wiring complete as per single line diagram.

1

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. Supply - 3x300 Sqmm

535

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

480

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

15

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

40

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

5

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

3

-

-

... More
10.6.4 : Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm.

2

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 gradestone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

50

-

-

... More
HT Metering Cubicle OUTDOOR WITH TOD METER: Supply, erection, testing and commissioning of dust and vermin proof, floor mounted free standing cubicle type 11kV outdoor metering panel box IP67, fully compartmentalised complete with hinged and earthed front doors with 3 phase 4 way 110V (L-L), 5A, class: 0.2 S, TOD meter with RS485 port, of Electricity board approved make including all necessary accessories for fixing and connection complete as required getting tested and approved from statutory authorities, providing connection/inter-connections as required for complete installation and as instructed by engineer in charge/consultant. Also the panels unit shall comprise of 3 Nos CT&apos of 10VA burden, and class Cl: 0.2 S and ratio depending on contract demand including fixed type PT of ratio 11kV/110V, 25VA, Cl: 0.2S (1 No.) and seal off bushing ; ABC Termination, space heater with thermostat including 630A Aluminium busbars with support insulators and all other accessories as required for complete installation as required and instructed by engineer in charge as per KSEB standards

1

-

-

... More
11KV Indoor Type Package Substation

-

-

-

... More
SITC of Indoor type Package substation, consists of the following: ;Supply, receiving, storing, inspection, handling, assembling, installation in correct aligned position, effecting proper connections, testing and commissioning of Indoor package type substation with 2 Nos.750 KVA,11/0.433 kV Dry type transformer, 4 mm thick base frame and 2 mm thick wall of each compartment naturally cooled type, as per the following specifications. A. 11KV HT VCB PANEL ;Incoming a). VCB 11kV 630A 3P 350 MVA - 1 No. with 24V DC trip ; built in power pack with battery backup ; charger ;b). Numerical relay (51) - 2 Nos ;c). Numerical relay (51N) - 1 No ;d). CR CT 150/5A 10VA CL:5P10 - 1 Set ;e). Annunciation Relay (30) - 1 No. with indicator ;f). Hooter - 1 No. ;g). Lamps for Breaker ON, OFF, TRIP, Spring charged ; Trip Circuit Healthy, 230V Spring Charged Motor, push Button for ON, OFF, TCH - 1 Set ;h). PT -11KV/110V 3 Phase 100VA CL-0.5 for incomer panel with Voltmeter ; selector switch - 1 set ;i). Termination - suitable for 3c 300sqmm XLPE cable ;j). Phase Indication Lamps with protection fuses or MCB s ; ;HT Busbar: 630A 350MVA TP +E BUS BAR. Outgoing-1, 2 ;3 ;a. VCB 11kV 630A 3P 350 MVA - 1 Set.with 24V DC built in power pack with battery backup with charger ;b. Numerical relay (50) (51) - 2 Set ;c. Numerical relay (50) (50N) - 1 Set ;d. CR CT 75/5A 10VA CL:5P10 - 1 Set ;e. CR CT 75/5A 10VA CL:1 - 1 Set ;f. Hooter - 1 No. ;g. Analogue Ammeter (0-75A) with Selector Switch - 1 Set. ;h. Annunciation Relay (30) - 1 No. with 8 Window Annunciator ;i. Auxiliary relays for T/F temperature alarm and trip Master trip relay (86) - 1 Set ;k.Termination -direct busbar connection to transformer primary. ;l. Indication lamps for Breaker ON, OFF, TRIP, Spring charged and Trip Circuit Healthy, push button for ON , OFF ; TCH, 230V Spring Charger Motor - 1Sets.Transformer: Supply, Installation, Testing and Commissioning of 2nos 750 kVA,11kV/433V, 3 phase, Copper Winding, Air Natural Cooling,DYN-11 Indoor Dry Type Transformer, with OLTC Tapping from -10% to +10% in steps of 2.5%, With Incoming and Outgoing cable boxes suitable for XLPE cable as per IS 2026/IS 11171/IS 2026 Part 2 2021 with latest amendment upto date. Transformer losses for 50% and 100% load shall be specified as per BEE 2017,Star 3 rating. ;Ratio - 11/0.433kV, 50Hz, 3Phase ;Capacity - 2 x 750 kVA (Indoor type) ;H.V side:- Cable end box suitable for 3corex300sq.mm 11kV XLPE cable and suitable for air terminations. ;L.V side:-Bus duct suitable for 1250A,TPN,IP54 Al. Sandwich Bus duct ;1 set of three nos. Winding Temperature Indicator on all the three phases.Detachable neutral link fabricated out of 50x6mm Cu strip of minimum length 150mm suitably bolted at both end and inserted in the neutral earthing conductor from the transformer bushing. Neutral CT of ratio 250/5A, class 5P10 15VA of accuracy for earth fault relay in a metallic enclosure including control wiring from the transformer.

1

-

-

... More
Supply,Installation, testing and commissioning of emergency isolation push button mounted in standard I.P 65 weather proof break glass enclosure to isolate the power Supplying to the building in case of emergency when the face glass is broken. Cost shall be including necessary connection to the trip coil of the equipment using 2.5 sq.mm 2 core copper armoured cable

4

-

-

... More
Diesel Generator

-

-

-

... More
Supply, Installation, Testing and Commissioning of 625 kVA prime rated D.G set with acoustic enclosure and control panel, protection and digital metering, controls and interlocks, CT s and transducers for all metering and protection with suitable size breaker, including antivibration mountings, exhaust silencer conforming to latest environment protection regulations for emission and noise levels, water/coolant cooled, ( radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz, 3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications.The work should be as per Electrical Inspectorate / pollution control board standards.

2

-

-

... More
EXHAUST PIPES:Supplying and fixing exhaust gas piping of suitable dia, welded black M.S B class pipe confirming to IS:3589 and as per latest CPCB norm cut to required lengths including all MS works with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh ; aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.

90

-

-

... More
Panel Boards, Enclosures and Accessories

-

-

-

... More
Main Switch Board:Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type Main Switch Board of CRCA No. 14 gauge sheet construction with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 50x6 mm copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. All panels must be BMS compatible. The type of construction of panels must be form 4B. Incomer:- (KSEB Side)) 2 Nos 1250A, 50 kA, 4P, ACB EDO,& micro P Based with 3O/C, 1E/Releases ; S/T, O/V relay with primary trip ; CT at neutral earthing conductor) 2 Set RYB Indication Lamp) 2A SP MCB 10kAd) 4 Set 1250/5A CL:1, 15VA CT e) 2 Nos (0-1250)A Ammeter with Selector Switch f) 2 Nos (0-500)V Voltmeter with Selector Switch g) 2 Nos of 51G relay h) 2 Nos. of Multifunction Digital meter V,A,F,KW,KVA,PF i) 2 Nos. of 64R Relay j) 2 Nos. of Under Voltage/Over Voltage Relay Incomer:- (DG Side) a) 2 Nos 1250A, 50 kA, 4P, ACB EDO,µ P Based with O/C, E/F, Releases ; S/T, O/V relay with primary trip.b) 2 Set RYB Indication Lamp c) 2A SP MCB 10kA d) 4 Set 1250/5A CL:1, 15VA CT e)2 Nos (0-1250)A Ammeter with Selector Switch f)2 Nos (0-500)V Voltmeter with Selector Switch g)2 No. of Multifunction Digital meter V,A,F,KW,KVA,PF h)1 No 1250A, 50 kA, 4P, ACB EDO,& micro P Based as Buscoupler Outgoings:-a) 4 Nos 800A, 50 kA, 4P, ACB EDO,& micro P Based with O/C, E/F, Releases ; S/T, O/V relay b) 10 Nos 630A, 50 kA, TP+NL, MCCB & micro P Based c) 1 No 630A TPN, Isolator ;d) 15 Sets of ON-OFF-TRIP Lamps with 2A fuse ;e) Surge Protection Devices for Main Panel: Type 1- 2 set ;f) 4 nos. of MFDM supporting RS485, with 2A fuse and CT 800/5A, Cl:1,15VA ;g) 10 nos. of MFDM supporting RS485,with 2A fuse and CT 630/5A,Cl:1,15VA ;1250 A 415V, 50kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required ;Details to be as shown in SLD.

1

-

-

... More
DG SYNC. PANEL :Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type DG Sync PANEL of CRCA No. 14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads. 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads. The main earth bus shall be of size 50 X 6 mm copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. All panels must be BMS compatible. The type of construction of panels must be form 4B. ;Incomer:- ;a)DG Incomer 1,2 - 1000A, 50 kA, TP, EDO, ACB Microprocessor based with thermal O/L, voltage controlled O/C relay, over voltage, under voltage, negative sequence, low set stand by earth fault relays and ref/differential relay + Neutral contactor - 2 Set ;b)3 Set RYB Indication Lamp ;c) 2A SP MCB 10kA ;d) 1000/5A CL:1, 15VA CT ;e) (0-1000)A Ammeter with Selector Switch ;f)(0-500)V Voltmeter with Selector Switch ;g)Multifunction Digital meter V,A,F,KW,KVA,PF ;h)Synchronization Relay for DG Incomer (DEIF- model no: AGC 232 for DG controller /Equivalent) - 2 Nos ;i)300A ,AC3 duty ,3P NL Contactor ;j)51G relay ;k)kWH meter for DG-2 Nos. ;l)3200A, FP, 50kA, EDO Microprocessor based ACB as Buscoupler - 2 Nos. ;Outgoings:- ;a)1250A, 50kA, FP, EDO Microprocessor Based ACB - 3 Nos ;b)3 Sets of ON-OFF-TRIP Lamps with 2A fuse ;c)3 nos. of MFDM supporting RS485,with 2A fuse and CT ;3200A 415V, 50kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement.Details to be as shown in SLD.

1

-

-

... More
HVAC MAIN PANEL: Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type HVAC CHILLER PANEL of CRCA No. 14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)800A,36 kA TP +NL,Microprocessor based EDO, ACB - 1 No. with O/C, E/F Releases ; S/T ;b)1 Set RYB Indication Lamp ;c)3 Nos 2A SP MCB 10kA ;d)3 Nos 800/5A CL:1, 15VA CT ;e)1 No (0-800)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 400A, 36kA, TP+ NL Thermal Magnetic Based MCCB - 4 Nos. ;b) 320A, 36kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. ;c) 5nos. of MFDM supporting RS485,with 2A fuse and CT d) ON-OFF-TRIP Lamps with 2A fuse. 800A 433V,36 kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Details to be as shown in SLD.

1

-

-

... More
HVAC Pump Panel ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)Incomer - 320 A TP+ NL MCCB Isolator - 1 No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 320/5A CL:1, 10VA CT ;e)1 No (0-320)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a)100A, 16kA, TP+ NL Thermal Magnetic Based MPCB - 1 No. ;b)63A, 16kA, TP+ NL Thermal Magnetic Based MPCB - 5 Nos. ;c)32A, 16kA, TP+ NL Thermal Magnetic Based MPCB - 3 Nos. ;d)25A, 16kA, TP+ NL Thermal Magnetic Based MPCB - 4 Nos.e) 13 Sets of ON-OFF-TRIP Lamps with 2A fuse ;320A, 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
MEDICAL EQUIPMENT PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ; ;Incomer:- ;a) 630 A, , 36kA , TP+ NL, EDO Microprocessor based MCCB - 1 No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 630/5A CL:1, 10VA CT ;e)1 No (0-630)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 250A, 25kA, TP+ NL Thermal Magnetic Based MCCB - 3 Nos. ;b) 200A, 25kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. ;c) 100A, 25kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. ;d) 5 Sets of ON-OFF-TRIP Lamps with 2A fuse ;630A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
COMMON SERVICE PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a) 630 A TP+NL MCCB Isolator - 1 No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 630/5A CL:1, 10VA CT ;e)1 No (0-630)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 320A 25kA TP+ NL Microprocessor Based MCCB - 2 Nos. ;b) 250A 25kA TP+ NL Microprocessor Based MCCB - 3 Nos.;c) 200A 25kA TP+ NL Microprocessor Based MCCB - 2 Nos ;d) 80A 25kA TP+ NL Microprocessor Based MCCB - 2 Nos e) 63A 25kA TP+ NL Microprocessor Based MCCB - 1 No. ;c) 8 Sets of ON-OFF-TRIP Lamps with 2A fuse ;630A 433V, 36kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
LIFT PANEL 1: Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B.Incomer:-a)80 A, TP+NL MCCB Isolator - 1No.b)1 Set RYB Indication Lampc)12 Nos 2A SP MCB 10kAOutgoings:-a)63A, 100 mA, FP, RCBO - 1 Nos.b)25A DP 30mA, MCB +ELCB - 1 Nos. c)2 Nos 6A, SP, 10kA, MCBDetails to be as shown in SLD."

2

-

-

... More
LIFT PANEL 2: Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B.Incomer: a)Incomer - 200A, FP, MCCB Isolator - 1No.b)1 Set RYB Indication Lampc)12 Nos 2A SP MCB 10kAOutgoings:-a) 63A, 100 mA, FP, RCBO - 3 Nos.b) 25A DP 30mA, MCB +ELCB - 2 Nos. c) 2 Nos 6A, SP, 10kA, MCB200A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Details to be as shown in SLD."

1

-

-

... More
LIFT PANEL 3 ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)Incomer - 200A, FP, MCCB Isolator - 1No. ;b)1 Set RYB Indication Lamp ;c) 2A SP MCB 10kA ;Outgoings:- ;a)63A, 100 mA, FP, RCBO - 4 Nos. ;b)25A DP MCB - 3 Nos. ;200A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Details to be as shown in SLD.

1

-

-

... More
PLUMBING PANELSupply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4sq.mm flexible copper earth leads. The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. The type of construction of panels must be form 3B.Incomer:-a)Incomer - 320 A 4P MCCB Isolator - 1 No.b)1 Set RYB Indication Lampc)12 Nos 2A SP MCB 10kAd)3 Nos 320/5A CL:1, 10VA CTe)1 No (0-320)A Ammeter with Selector Switchf)1 No (0-500)V Voltmeter with Selector Switchg)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PFOutgoings:-a)125A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 2 Nos.b) 63A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 3 No. c) 50A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. d) 32A, 16kA, TP+ NL Thermal Magnetic Based MCCB - 5 Nos.f) 9 Sets of ON-OFF-TRIP Lamps with 2A fuse320A, 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD."

1

-

-

... More
MEDICAL GAS PLANT PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)200A FP 25kA thermal magnetic release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 200/5A CL:1, 10VA CT ;e)1 No (0-200)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a)50A 16kA TP+ NL MCCB, with thermal magnetic release - 4 Nos. ;b) 40A 16kA TP+ NL MCCB, with thermal magnetic release - 1 Nos. ;c) 32A 16kA TP+ NL MCCB, with thermal magnetic release - 2 No. ;200A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Details to be as shown in SLD.

1

-

-

... More
CSSD PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)250 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 250/5A CL:1, 10VA CT ;e)1 No (0-250)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a)100A 16kA TP+ NL MCCB, with thermal magnetic release - 3 Nos. ;b) 63A 16kA TP+ NL MCCB, with thermal magnetic release - 2 Nos. ;c) 40A 16kA TP+ NL MCCB, with thermal magnetic release - 1 No. ;d) 32A 16kA TP+ NL MCCB, with thermal magnetic release - 2 No. ; ;250A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Details to be as shown in SLD.

1

-

-

... More
LG 1 FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a) 250 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 250/5A CL:1, 10VA CT ;e)1 No (0- 250)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 200A 16kA TP+ NL Thermal Magnetic Based MCCB -2 Nos. ;b) 40A 16kA TP+ NL Thermal Magnetic Based MCCB - 5 Nos. ;c) 25A 16kA TP+ NL Thermal Magnetic Based MCCB - 3 No ; ;250A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
GF FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)125 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 125/5A CL:1, 10VA CT ;e)1 No (0- 125)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a)40A 16 kA TP+ NL Thermal Magnetic Based MCCB - 5 Nos. ;b) 25A 16kA TP+ NL Thermal Magnetic Based MCCB - 3 No.125 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
1F FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)125 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 125/5A CL:1, 10VA CT ;e)1 No (0- 125)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 40A 16 kA TP+ NL Thermal Magnetic Based MCCB - 5 Nos. ;b) 25A 16kA TP+ NL Thermal Magnetic Based MCCB - 3 No. ; ;125 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
2F FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)160 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 160/5A CL:1, 10VA CT ;e)1 No (0- 160)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a)40A 16kA TP+ NL Thermal Magnetic Based MCCB - 7 Nos. ;b) 25A 16kA TP+ NL Thermal Magnetic Based MCCB - 3 No. ; ;160 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD. ;

1

-

-

... More
3F FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)200 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 200/5A CL:1, 10VA CT ;e)1 No (0- 200)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 50A 16kA TP+ NL Thermal Magnetic Based MCCB - 2 Nos. ;b) 40A 16kA TP+ NL Thermal Magnetic Based MCCB - 6 Nos. ;c) 25A 16kA TP+ NL Thermal Magnetic Based MCCB - 3 No. ; ;200 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
4F FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)200 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 200/5A CL:1, 10VA CT ;e)1 No (0- 200)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 50A 16kA TP+ NL Thermal Magnetic Based MCCB - 1 No. ;b) 40A 16kA TP+ NL Thermal Magnetic Based MCCB - 6 Nos. ;c) 25A 16kA TP+ NL Thermal Magnetic Based MCCB - 3 No. ; ;200 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
5F FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)160 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 160/5A CL:1, 10VA CT ;e)1 No (0- 160)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 63A 16kA TP+ NL Thermal Magnetic Based MCCB - 3 Nos. ;b) 50A 16kA TP+ NL Thermal Magnetic Based MCCB - 1 No. ;c) 40A 16kA TP+ NL Thermal Magnetic Based MCCB -4 No. ;d) 25A 16kA TP+ NL Thermal Magnetic Based MCCB -3 No. ; ;160 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD. ;

1

-

-

... More
6F FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)250 A FP 25kA Thermal Magnetic Release MCCB - 1No ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 250/5A CL:1, 10VA CT ;e)1 No (0- 250)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 160A 16kA TP+ NL Thermal Magnetic Based MCCB - 1 No. ;b) 63A 16kA TP+ NL Thermal Magnetic Based MCCB - 4 Nos. ;c) 40A 16kA TP+ NL Thermal Magnetic Based MCCB - 2 Nos. ;d) 25A 16kA TP+ NL Thermal Magnetic Based MCCB -3 Nos. ; ;250 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
7F FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)250 A FP 25kA Thermal Magnetic Release MCCB - 1No ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 250/5A CL:1, 10VA CT ;e)1 No (0- 250)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 200A 16kA TP+ NL Thermal Magnetic Based MCCB -1 No. ;b) 160A 16kA TP+ NL Thermal Magnetic Based MCCB - 2 Nos. ;c) 120A 16kA TP+ NL Thermal Magnetic Based MCCB - 1 No. ;c) 63A 16kA TP+ NL Thermal Magnetic Based MCCB - 5 Nos. ;d) 40A 16kA TP+ NL Thermal Magnetic Based MCCB -1 No. ;e) 25A 16kA TP+ NL Thermal Magnetic Based MCCB -3 No. ; ;250 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
5F UPS FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)125 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 125/5A CL:1, 10VA CT ;e)1 No (0- 125)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 63A 16kA Thermal Magnetic TP+ NL MCCB -2 No. ;b) 40A 16kA Thermal Magnetic TP+ NL MCCB -5 No. ;c) 25A 16kA Thermal Magnetic TP+ NL MCCB -3 No. ; ;125 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
6F UPS FLOOR PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)200 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 200/5A CL:1, 10VA CT ;e)1 No (0- 200)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a)125A 16kA TP+ NL Thermal Magnetic Based MCCB - 2 Nos. ;b) 63A 16kA TP+ NL Thermal Magnetic Based MCCB -1 No. ;c) 40A 16kA TP+ NL Thermal Magnetic Based MCCB -4 Nos. ;d) 25A 16kA TP+ NL Thermal Magnetic Based MCCB -3 Nos. ; ;200 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
6F OT PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a)- 125 A FP 25kA Thermal Magnetic Release MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 125/5A CL:1, 10VA CT ;e)1 No (0-125)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a)63A 16kA Thermal Magnetic TP+ NL MCCB -9 No. ; ;125 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
UPS INPUT PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a) 500A, 36kA, FP TM Based MCCB - 1No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 500/5A CL:1, 10VA CT ;e)1 No (0-500)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 250A, 36kA, TP+ NL, MCCB - 3 Nos. ;500 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
UPS OUTPUT PANEL ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ;Incomer:- ;a) 250A, 36kA, FP TM Based MCCB - 3No. ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 250/5A CL:1, 10VA CT ;e)1 No (0-250)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings:- ;a) 200A FP 36kA TM Based MCCB - 1 No. ;b) 125A FP 36kA TM Based MCCB -2 Nos. ;c) 63 A FP 36kA TM Based MCCB -9 Nos. ; ;250 A 433V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
APFC PANEL -350 kVAr ;Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size 25x3 mm copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 3B. ; ;Adequate forced ventilation arrangement shall be provided by means of a cubicle type fan of capacity 225 m3/hr also with contactor thermostat control. Control fuses shall be provided for the fan circuit. Lamp indication shall be provided to indicate the working/ non- working states of the fan. ;The capacitor compartment shall be so constructed that in case of any capacitor failure, fluid leakage or fumes from the field capacitor shall not affect the capacitors in the other compartments. The inter-compartmental partition of capacitor chamber shall be perfectly done. The capacitor shall be rated for a voltage 480 V or above and conform to IS - 2834. ;Incomer ;a)1 No 800A 36kA 4P ACB ;b)1 Set RYB Indication Lamp ;c)12 Nos 2A SP MCB 10kA ;d)3 Nos 630/5A CL:1, 10VA CT ;e)1 No (0-800)A Ammeter with Selector Switch ;f)1 No (0-500)V Voltmeter with Selector Switch ;g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF ;Outgoings ;a)13 Nos. 63A TPN,36kA MCCB ;b)1 Nos. 40A TPN,36kA MCCB ;c)1 No. 32A TPN,36kA MCCB ;Capacitor: ;25kVAR Capacitor Duty Contactor - 13 Nos ;15kVAR Capacitor Duty Contactor - 1 No ;10kVAR Capacitor Duty Contactor - 1 No ;25kVAR Heavy Duty Capacitor Box Type Resin Filled -13 Nos ;15kVAR Heavy Duty Capacitor Box Type Resin Filled -1 No ;10kVAR Heavy Duty Capacitor Box Type Resin Filled -1 No ;7% detuned reactor – 15 nos. ;15 Stage APFC Relay - 1 No ;Complete with all Control Wiring Components such as Control Contactors, Selector Switch, Push Button with Elements, Control MCB s etc. as required.

2

-

-

... More
Distribution Boards

-

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required ;12 way (8+36) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO/MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

7

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

3

-

-

... More
90.11.1.13 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required required12 way (8+36) - three phase double cover (IP 42/43)

6

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - three phase double cover (IP 42/43)

43

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required required6 way (8+18) - three phase double cover (IP 42/43)

48

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required way (8+12) - three phase double cover (IP 42/43)

36

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door)

10

-

-

... More
2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door

10

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

12

-

-

... More
Supplying and fixing following rating 25A, FP, 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;

31

-

-

... More
Supplying and fixing following rating 32A, FP, 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;

27

-

-

... More
Supplying and fixing following rating 25A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;

5

-

-

... More
Supplying and fixing following rating 32A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;

21

-

-

... More
Supplying and fixing following rating 40A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;

43

-

-

... More
Supplying and fixing following rating 63A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;

6

-

-

... More
Supplying and fixing following rating 25A, DP, 240 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;

20

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1682

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, D curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;Single pole

1032

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

5

-

-

... More
2.10.2 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural

30

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

35

-

-

... More
Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;Triple pole ;

6

-

-

... More
Supplying and fixing 25 amps to 32 amps TPMCB 415 V, 10 kA, “D” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

23

-

-

... More
Supplying and fixing 40 amps to 63 amps TPMCB 415 V, 10 kA, “D” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required

40

-

-

... More
Supplying and fixing 63 amps TM 4P MCCB 25KA in the existing Vertical DB complete with connections, testing and commissioning etc. as required. ;

14

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

50

-

-

... More
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL.

1

-

-

... More
Supply and fixing of 32A TPN Isolator in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. ;

8

-

-

... More
Supply and fixing of 32A TPN Isolator ( W/P) in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. ;

6

-

-

... More
Supply and fixing of 32A DP Isolator in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. ;

4

-

-

... More
Supply and fixing of 40A DP Isolator (Car Charging) in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. ;

5

-

-

... More
Supply and fixing of 63A TPN Isolator in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. ;

5

-

-

... More
Supply and fixing of 63A TPN Isolator(W/P) in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. ;

4

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

10

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

8

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

114

-

-

... More
LT Cabling and Termination

-

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3.5CX400 ;

2340

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3.5CX300

234

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3.5CX240

324

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3.5CX185

328

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3.5CX150

198

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3.5CX120

162

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3.5CX95

36

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3.5CX70

484

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3.5CX50

144

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx35sq.mm Al Cable

484

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;4CX25

144

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;4CX16

2464

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;4CX10

3964

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;4CX6

601

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. ;3CX185

42

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3CX16 sq.mm Al Cable ;

48

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3cx04sq.mm CU Cable ;

50

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3cx2.5sq.mm CU Cable ;

75

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3C x 1.5sq.mm Cu Control Cable ;

52

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 6C x 1.5sq.mm Cu Control Cable ;

40

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4C x 1.5sq.mm Cu Control Cable ;

120

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4C x 2.5sq.mm Cu Control Cable ;

50

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 12C x 2.5sq.mm Cu Control Cable ;

320

-

-

... More
Supply laying and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages etc. as required and instructed by engineer in charge.e. 1C x 70 sq.mm Cu flexible Cable

486

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

880

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

20

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

40

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

120

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm.

120

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

90

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

50

-

-

... More
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

80

-

-

... More
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm

350

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

7040

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

1012

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

594

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

2308

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

150

-

-

... More
14.3 : Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres.

120

-

-

... More
14.4 : Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.

256

-

-

... More
14.5 : Deduct for not consolidation by ramming and watering while re-filling with sand and or good soil in cable/ pipe laying.

50

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

18

-

-

... More
14.15.4 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal)

450

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm

82

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

10

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

18

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

24

-

-

... More
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

4

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

8

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

6

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

24

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

4

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

52

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

30

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

92

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

292

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ;4C X 06 sq. mm (22mm) ;

12

-

-

... More
9.1.16 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 185 sq. mm (57mm)

4

-

-

... More
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

4

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3cx04sq.mm CU Cable ;

20

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. . 3cx2.5sq.mm CU Cable ;

60

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. .. 3C x 1.5sq.mm Cu Control Cable ;

36

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 6C x 1.5sq.mm Cu Control Cable ;

12

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. . 4C x 1.5sq.mm Cu Control Cable ;

12

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. . 4C x 2.5sq.mm Cu Control Cable ;

12

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 12C x 2.5sq.mm Cu Control Cable ;

12

-

-

... More
90.12.24.9 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 70 sq mm

54

-

-

... More
Providing, laying and fixing following dia RCC pipe NP4 class (Heavy duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. ;300 mm dia pipe for cable ;

45

-

-

... More
Earthing

-

-

-

... More
Supply of all materials and providing plate earth station with 1200 x 1200 x 12.5 mm. C.I. plate earth electrode, water pipe, earthing strips, clamps, funnel, Electrodes etc., excavation in all classes of soil,terminal filling with homogeneous mixture of charcoal and salt and back filling ,construction of Earthpit Inspection Chamber and Heavy duty C.I. Chequered plate for Earthpit Inspection Chamber cover. The rate quoted shall be including the excavation, construction of chamber, CI cover back filling

15

-

-

... More
Supply of UL Listed ; CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250 micron tested as per IEC 62561-2 ; is provided with universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided with Heavy duty earth chamber with dimension of 300mmx 300mmx 450mm of 5000kg load bearing capacity to ensure the safety of earthing system including all accessories as required for complete installation as instructed by engineer in charge. ;

6

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant. ;50x6 Cu strips tinned at the point of contact.

352

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant. ;25x6 Cu strips tinned at the point of contact.

198

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant. ;25x3 Cu strips tinned at the point of contact.

72

-

-

... More
Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant. ;50x6 Cu strips tinned at the point of contact.

238

-

-

... More
Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant. ;32x6 Cu strips tinned at the point of contact.

198

-

-

... More
Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant. ;25x6 Cu strips tinned at the point of contact.

275

-

-

... More
Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant. ;25x3 Cu strips tinned at the point of contact.

1925

-

-

... More
5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.

4

-

-

... More
5.20 : Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

18

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)

413

-

-

... More
Supplying and Providing earthing conductors with necessary sockets for terminations of the following sizes along with wiring/ cables and giving connection as required.10 SWG ;

50

-

-

... More
Lighting Protection

-

-

-

... More
2meter air terminal with accessories ;Providing and fixing Air terminals as per IEC -62305 part-3 and IS 2309 16mm rod tapered to 10 mm aluminium rod 2 meter rod: ;Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) 101 VL 3000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected. Fang fix clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. 2 no s of 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked.

7

-

-

... More
8mm solid aluminium round conductor: ;supply and providing 8mm solid aluminium round conductor, meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. ;Polyamide Conductor holder with holding base for parapet/Flat roof: ;With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. ;Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. ;a) Vertical run- Down conductor

850

-

-

... More
8mm solid aluminium round conductor: ;supply and providing 8mm solid aluminium round conductor, meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder with holding base for parapet/Flat roof: ;With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. ;Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. ;b) Horizontal run-Parapet application

420

-

-

... More
Providing and fixing of Conductor holder for 8mm solid aluminium round conductor: For concrete building Terrace application: Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). ;Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. With double conductor holder. Filling weight 1Kg (frost-resistant concrete). Sleeve made of polyethylene, black, bottom polypropylene, black. Base made of polyamide PA 6, black, UV-stabilised and weather-resistant. Base can be used on almost all roofing felt systems (bitumen, PVC). Conductor holder @ 1 meter distance.

30

-

-

... More
Providing and fixing of Ridge conductor holder for round conductor Rd 8 with tensioning spring - Stainless steel Conductor holder: With Bottom section and conductor holder stainless steel (V2A), grade 304 ;Clamping range 280-380 mm. Conductor holder @ 1 meter distance.

70

-

-

... More
Providing and fixing of cross connector/T connector: to route vertical down conductor /mesh formation made of stainless steel/hot dipped galvanised iron with necessary screws etc as required. It should meets the requirements of VDE 0185-305-3 (IEC/ EN 62305-3). And should be tested for minimum Lightning current carrying capacity - H/100 kA. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts ;

65

-

-

... More
Providing and fixing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. Made of round conductor Rd 8-Alu. Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade stainless steel. It should be tested for minimum Lightning current carrying capacity - H/100 kA. Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305) ;

16

-

-

... More
Providing and fixing of Equipotential bonding rail for outdoor use.

5

-

-

... More
Providing and fixing of Test Joint (Folding Clamp, Plate thickness to 5 mm) made of Stainless steel(V2A), grade 304. For conductor routing transverse and longitudinal to plate. Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305). It should be tested for minimum Lightning current carrying capacity - N/50 kA. Suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Enginee ;

27

-

-

... More
Providing and laying Galvanised Steel Flat 30X3 mm thick from earth electrode directly in ground as required. Hot Dip GI strip, corrosion resistant. Cross sectional area of 90mm square ;According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IEC 62305) Zinc coating: 500 g/m square (70 micron coating) Should be tested and use exclusively for lightning protection earthing system and ring equipotential bondin ;

400

-

-

... More
Providing and fixing of Cross connector for Flat: Meets the requirements of VDE 0185-305-3 (IEC/ EN 62305-3). It should be tested for minimum Lightning current carrying capacity - H/100 kA. Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate.

60

-

-

... More
Providing and fixing of flat conductor holder suitable for FL 30 with round pin. Made of hot dipped galvanised iron with crossbar and 2 hexagonal bolts (VA). ;

27

-

-

... More
Providing maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 14.2 mm with copper coating thickness of 250 microns with fault current withstand capability of 13 KA rms value for 1 second and I peak of 31 KA. Universal Clamp (14 25 RTC) made of SS 304 for clamping. Earth enhancing compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances The mineral compound is required to have 25 kg/pit of the total composite. Polypropylene ; Polyethylene (UFE)Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 250mmx 250mmx 250mm with a weight bearing capacity of 50KN ;

27

-

-

... More
Providing of Plastic Corrosion Protection strip: Approx. 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. ;

3

-

-

... More
Wiring and Accessories

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

2383

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

25

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

1258

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

1260

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

1858

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

821

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

821

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

27836

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

37208

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

10417

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

500

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

500

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

100

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

20

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

894

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

582

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

180

-

-

... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

602

-

-

... More
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

50

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

398

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

2025

-

-

... More
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

132

-

-

... More
1.57 : Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

25

-

-

... More
Light Fixtures

-

-

-

... More
Supply of 2x 2 LED Recess mounted light fixture 24W with System efficacy of 120 lm/W and system lumen output 2880 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 2KV internal surge protection, power factor 0.95,THD10%, rated life of 50,000 hours with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Philips- RC380B LED30S-5700 G5 L60W60 PSU OD, Wipro- CRCO10R024HP57HE G2, Bajaj:BZRSQL 24W XE WH."

962

-

-

... More
Supply of 2x2 LED Recess mounted light fixture 36W with UGR19 System efficacy of more than 100lm/W and system lumen output 3600lm.Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 2KV internal Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Philips: RC380B LED36S-5700 G5 L60W60 PSU OD, CRCO10R030HP57UGG2, Bajaj: BZRSQL 30L XE WH OD SD

444

-

-

... More
Supply of 2x 2 LED Recess mounted light fixture 30 W with System efficacy of 120 lm/W and system lumen output 2880 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 2KV internal surge protection, power factor 0.95,THD10%, rated life of 50,000 hours with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Philips- RC380B LED36S-5700 G5 L60W60 PSU OD, Wipro- CRCO10R030HP57HE G2, Bajaj:BZRSQL 36W XE WH."

450

-

-

... More
Supply of 2x 2 LED Recess mounted 42W Clean Room light fixture Bottom Opening with Screwless frame System efficacy of 100 lm/W and system lumen output 2880 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 2KV internal surge protection, power factor 0.95,THD10%, rated life of 50,000 hours with a CRI of 80 or above,ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Philips-CR652B LED33S CR CW CA, Wipro LC20-551-XXX-57-G2M Bajaj: BPRF 36W WH LED.Integral, SMD 2x2 LED ,IP 65

317

-

-

... More
Supply of LED Downlights Recess /Surface mounted 15W LED luminaire of Die Cast Aluminium Housing, driver with minimum 4KV Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 100 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture.Makes: Philips- DN295B LED6S-5700 PSU WH, Wipro- LD06 171 XXX 57 XX/ SM G1 Bajaj: BGSLO SLEEK 6W WH RD.

392

-

-

... More
Supply of LED Downlights Surface mounted 18W LED luminaire of Die Cast Aluminium Housing, driverwith minimum 2KV Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 100 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Philips- DN295BLED6S-5700 PSU WH, Wipro- LD06 221 XXX 57 XX/ SM G1 Bajaj: BGSLO SLEEK 6W WH RD.

39

-

-

... More
"Supply of LED Tube Lights of 20W with Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 2KV Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia-Japan/ Cree-USA / Bridgelux-USA / Lumiled-USA / Citizen-Japan / Osram should be provided and including all necessary accessories as required for the light fixture.Makes: Philips- BN308C LED20S-6500 L120 PSU WH, Wipro- LL24-251-XXX-57-XX, Bajaj: BCLAB 20W

30

-

-

... More
Supply of LED Tube Lights of 40W(+/- 10% Tolerance) with Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 2KV Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture.. Makes: Philips- BN308C LED40S-6500 L120 PSU WH, Wipro- LL24-541-XXX-57-XX, Bajaj: BCLAB 40W

416

-

-

... More
Supply of LED Mirror Lights of 10W(+/- 10% Tolerance) with polycarbonate diffuser having driver of minimum 2KV Surge protection, power factor 0.9,THD10%, system efficacy greater than or equal to 80 lm, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. Makes: Philips, Wipro, Bajaj.

74

-

-

... More
SITC of Bulkhead of 10W(+/- 10% Tolerance) with polycarbonate diffuser having driver of minimum 2KV Surge protection, power factor 0.9,THD10%, system efficacy greater than or equal to 80 lm, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. Makes: Philips, Wipro, Bajaj

90

-

-

... More
Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 8 Meters.

10

-

-

... More
Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

10

-

-

... More
Supply, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. ;1200mm sweep - 5star rated BLDC Ceiling fan complete with 300mm down rod , canopies, shackles and blades and resistance type regulator working on 230V/240V single phase A/C

582

-

-

... More
SITC of Wall fan

5

-

-

... More
SITC of Industrial Type 400mm Sweep Exhaust fan

5

-

-

... More
SITC of LED Aviation Light

1

-

-

... More
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required

240

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

3214

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

1490

-

-

... More
EXTERNAL FEEDER PILLAR ;Supply and installation of Thermoplastic polycarbonate Junction Box IP67. Junction box should be made of thermoplastic Polycarbonate, having IP 67 degree of protection and 5pole terminals suitable to terminate up to 2.5sqmm. The color of Junction boxes shall be Siemens Grey RAL7035. The gasket should be internally embedded, and made of Polyurethane The boxes shall be tested as per IEC 60670-2 / 60670-22. The boxes shall have self- threaded holes ; provision for mounting din rail, The boxes should withstand temperature of -40c to +120c, The glow wire test should be conducted at 960c, and material should be flame retardant ; self- extinguishing. UL subject 94, V-0. The boxes should be free of toxic substances like halogen and silicon, The boxes should have suitable pre-molded knock out, suitable size IP68 polyamide glands shall be provided for in and out cables / wires. Incomer: 63A,TPN Isolator,63A ,30mA RCCB,Outgoing: 15 nos. 6/10/16/20A SP MCBs , 10KA.

1

-

-

... More
Rising Mains, BBT and Tap Off Boxes

-

-

-

... More
Supply, erection, testing and commissioning of following capacity auto transfer switch ATys M 3s C30 with enclosure, bus bars and all accessories required for complete operation as per the drawing. The ATS should be double break contact system for high short time withstand. ATS shall be with UV/OV, Phase sequence, Single phasing and frequency protections. ;250A 4P ATS ;

4

-

-

... More
Supply, erection, testing and commissioning of following capacity auto transfer switch ATys M 3s C30 with enclosure, bus bars and all accessories required for complete operation as per the drawing. The ATS should be double break contact system for high short time withstand. ATS shall be with UV/OV, Phase sequence, Single phasing and frequency protections. ;200A 4P ATS ;

4

-

-

... More
Supply, erection, testing and commissioning of following capacity auto transfer switch ATys M 3s C30 with enclosure, bus bars and all accessories required for complete operation as per the drawing. The ATS should be double break contact system for high short time withstand. ATS shall be with UV/OV, Phase sequence, Single phasing and frequency protections. ;160A 4P ATS ;

4

-

-

... More
Supply, erection, testing and commissioning of following capacity auto transfer switch ATys M 3s C30 with enclosure, bus bars and all accessories required for complete operation as per the drawing. The ATS should be double break contact system for high short time withstand. ATS shall be with UV/OV, Phase sequence, Single phasing and frequency protections. ;125A 4P ATS ;

6

-

-

... More
Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated Sandwich Type, epoxy insulated, compact, sandwitched outdoor type (TPN) bus trunking on wall / ceiling / structure, with high conductivity aluminium conductor in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with bends, expansion joints, fire barriers at wall/ceiling crossing, copper flexible end connections, elbows. The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 5 mm copper strip (Cu strip shall go inside LT panels and end termination boxes) on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The bus duct shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical bus trunking shall be furnished. Rate shall be quoted for including bends, copper flexible, supports, hangers, flanged ends, adaptor box with terminal kits and all accesories required for complete installation. ;1250A Al TPN, 50 kA, IP54 Feeder busduct ;

80

-

-

... More
Supply, installation, testing and commissioning of following capacity type tested as per IEC 61439 Part 6, pre-fabricated Sandwich type, epoxy insulated, compact, sandwitched indoor type (TPN) rising mains on wall, with high conductivity aluminium conductor in convenient sections suitable for 3 phase 4 wire 50Hz, 415V, AC supply. The bus bar shall be complete with expansion joints, fire barriers at each floor crossing, copper flexible end connections. end cap etc . The housing shall be constructed from 1.6mm (min) thick electro galvanised sheet steel enclosure, IP54 with epoxy coated. The busduct shall be complete with 4 nos aluminium busbar. Earthing with 2 runs of copper earth of size 25 x 5 mm copper strip on each side including clamping bracket, angle iron bracket, steel fastners, connecting to earthing system etc as required, including supports for bus bars. The rising mains shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of identical rising mains shall be furnished including all accesories required for complete installation. ;630A,50kA Al TPN IP54 Rising Mains ;

210

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. ;250 A 50kA TPN MCCB in Tap off box ;

4

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. ;125 A 50kA TPN MCCB in Tap off box

6

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. ;200 A 50kA TPN MCCB in Tap off box

4

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. ;160 A 50kA TPN MCCB in Tap off box

4

-

-

... More
Cable Tray

-

-

-

... More
4.1.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

285

-

-

... More
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2260

-

-

... More
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

1025

-

-

... More
4.1.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

125

-

-

... More
4.2.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required600 mm width X 50 mm depth X 2.0 mm thickness

10

-

-

... More
4.2.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required300 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
4.2.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required150 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
4.2.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required100 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
4.3.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

10

-

-

... More
4.3.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
4.3.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
4.3.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
4.4.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

5

-

-

... More
4.4.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

45

-

-

... More
4.4.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

45

-

-

... More
4.4.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
4.5.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

10

-

-

... More
4.5.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

75

-

-

... More
4.5.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

75

-

-

... More
4.5.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
UPS

-

-

-

... More
100 X 3 KVA (Parallel Redundant System) with Three Phase Input and Output :- The Three Phase input Voltage shall be 4wire, 415V, variable between +20% to –20%; 50Hz +/- 6%. The UPS System shall deliver Clean; ripple free output waveform in presence as well as failure of supply mains. The current and voltage harmonic distortions generated by the UPS systems shall be with in acceptable limits as per international and national norms. (Ripple [without Battery 1 %]), (THD 2% max, for 100% Linear load 5% max, for 100% Non-Linear load)" UPS system shall be Double conversion, Microprocessor based True On Line system with individual battery banks having in-built galvanic Isolation Transformer at output and own Cooling arrangements. UPS system shall be with LCD Display, 3 input and 3 output; with PWM IGBT based DSP control, 20 Minutes external SMF battery backup and auto by-pass. Specification for 100 X 3 KVA Online UPS (PRS) "INPUT : Input Voltage Range -3, 4 Lines + Ground, 415V ± 20% Power factor - 0.98 Frequency Range - 50 Hz, ± 10% Topology - IGBT based DSP control" "OUTPUT: Voltage Range - 415V ± 0.5% Frequency Range - 50 Hz, ± 0.05% O/P Power factor - Minimum 0.9 THD (Linear Load) - 2% THD (Non Linear Load) - 5% Crest Factor - 3:1 Efficiency - 95% Over load capacity - 110% - 5min , 150% - 30s" Battery Backup Required Battery backup time required is 20 Min. using External Exide / HBL / Quanta Make SMF Batteries for each UPS. The product of the offered battery Ah capacity and the total rated DC Bus voltage shall be a minimum of 120,000 (for SMF battery). "1. The entire UPS Systems shall be Tested, Supplied, and Erected and commissioned by supplier including all the components of the system such as Paralleling Kit, Batteries, Battery Rack, Interconnecting wires and Socket / Outlets. 2. The UPS System shall be rated continuously to deliver 100% of rated output at power factor of 0.9 lag to unity within KVA & KW rating. 3. Following original accessories / protective devices shall be provided for the UPS System. [a] Overload and Short Circuit Protection for Input and Load sides [b] Over voltage & under voltage Protection for UPS and Load [c] Low Battery [d] Over Temperature [e] LED Indications for Battery, Mains and Input Supply ON, Inverter ON, Static bypass. 4. The following connectors of adequate rating shall be provided for the UPS system [a] Power Outlet for connection to Load [b] Terminal connectors for connection to external Batteries [c] Connection to computer system for UPS Monitoring 5. The UPS and Battery System shall be suitable for installation in a Saline tropical area with relative humidity up to 95% and at altitudes of up to 1000 Mtrs above MSL without degradation. The ambient temperature is variable between +18deg.Centigrade to + 40deg. Centigrade. 6. The design of the UPS System and all components shall be tropicalised so as to ensure efficient and trouble free operation in the local climate. UPS Systems shall be despatched only after completing all Routine tests strictly complying to IEC 62040 – PART III . The complete set of test certificates shall be send to the Consultant before despatching the equipment. All tests shall be conducted to the entire satisfaction of the Engineer in Charge / Consultant. Any additional tests indicated by the Consultant if any / tests results he may think as unsatisfactory, shall be done without extra charges.

1

-

-

... More
Miscellanoue

-

-

-

... More
Supply and providing 6mm thick MS chequered plates duly painted. Plates to be cut size as per site requirement. ;

80

-

-

... More
Supply and providing First Aid Box. ;

2

-

-

... More
Supplying, Fixing First Aid Chart duly framed and placed in a conspicuous location for clear vision. ;

8

-

-

... More
Supply fixing Approved Electrical Scheme/ Layouts printed in 6mm thick Transperent Acrylic sheet fixed with suitable SS Studs in walls as directed by Engineer in charge. ;

10

-

-

... More
Painting letters or figures of 2.5cm/4.5cm sizes with enamel paint as identification mark to SB, DB, panel board etc as required ;

1

-

-

... More
Supplying and Providing 15 long rubber hand gloves 15 kV ;

3

-

-

... More
Supply and providing ISI marked electrical 3.3kV Grade 2m x 1m x 6mm thick anti-skid insultion mat as per IS ;

60

-

-

... More
Supply and Providing ISI marked electrical 11kV Grade 2m x 1m x 12 mm thick anti-skid insulation mat as per IS ;

20

-

-

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters FIRE in black and gold. Cost shall be inclusive of providing MS stand for 2 nos of fire buckes, or , duly painted over a coat of primer. ;

12

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. ;

5

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. ;

12

-

-

... More
Extra Low Voltage (ELV) System Data

-

-

-

... More
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT6 Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc.including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

294

-

-

... More
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT 6A Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

34

-

-

... More
CAT6 Cable - Supplying and drawing of Category 6 cable consists of 4 pairs of solid insulated copper 23AWG, surface/ recessed medium class PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation

19895

-

-

... More
CAT 6A Cable - Supplying and drawing of Category 6A cable consists of 4 pairs of solid insulated copper 23AWG, surface/ recessed medium class PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation

1979

-

-

... More
OFC Cable - Supplying and drawing of 6 core SM armored Optical Fibre Cable (OFC) through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

966

-

-

... More
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 2 Meter length etc. of approved make as required for complete installation.

294

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 1 Meter of approved make as required for complete installation.

294

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of Fibre Patch Cable - 2 Meter of approved make as required for complete installation.

31

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of CAT6A Patch Cable - 1 Meter of approved make as required for complete installation.

34

-

-

... More
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6A Patch Cable - 2 Meter length etc. of approved make as required for complete installation

34

-

-

... More
Voice

-

-

-

... More
Information Outlet RJ 11 - Supply, fixing, testing and commissioning of RJ11 Information Outlets (Keystone) with shuttered Faceplate, single port, white, jack, suitable PVC / GI Modular Box etc. includingnecessary connections with all accessories required for complete installation as directed by the Engineer in charge.

227

-

-

... More
Cable - Supplying and drawing of following pair telephone cable consists of 0.5 mm dia FR, PVC Compound annealed copper conductor, unarmored telephone cable in surface / recessed medium class FRLS PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

10898

-

-

... More
Cable - Supplying and laying of following pair armoured telephone cable through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 10 Pair Telephone Cable

260

-

-

... More
Cable - Supplying and laying of following pair armoured telephone cable through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 20 Pair Telephone Cable

325

-

-

... More
Cable - Supplying and laying of following pair armoured telephone cable through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 50 Pair Telephone Cable

156

-

-

... More
krone Box - Supply, erection, testing and commissioning of following pair krone Box with mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 10pair

4

-

-

... More
krone Box - Supply, erection, testing and commissioning of following pair krone Box with mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 20pair

6

-

-

... More
krone Box - Supply, erection, testing and commissioning of following pair krone Box with mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 50pair

3

-

-

... More
krone Box - Supply, erection, testing and commissioning of following pair krone Box with mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 300 Pair MDF Krone

1

-

-

... More
Supply, Installation, Testing and Commissioning of "PBX with 227 Analog extensions expandable up to 400, 20 SIP/ IP license with minimum of 20 concurrent calls, 1 PRI interface, 4 analogue trunk lines, Failover Function, Web Interface, Call Dashboard, DISA, IVR, Call Hunt etc. including two numbers master console phone & short key / Direct Station Selection (DSS) Console. "Built-In Auto Answer TDM/IP Coverage ISDN Compatibility Voice Mail Integration Paging Announcement Programmable Function Keys"" Call Waiting"

1

-

-

... More
Supply, installation, testing and commissioning of Basic user phone with necessary connection as required for complete installation as directed by the engineer in charge

227

-

-

... More
Surge Protection Device For EPABX: Supply, Installation, Testing and commissioning of SPD with enclosure, the surge protection device shall be suitable to protect telephone lines designed to with stand both lightning current and switching surges. Technology: GD tube, Nominal Voltage: 180 V, Pulsed Current (10/350 μs ) Iimp: 1 KA, Nominal Discharge Current (8/20 μs )/phase In: 5KA, Maximum discharge current: 10 KA,Voltage Protection Level(sym)700V, Response time1n sec

1

-

-

... More
Closed Circuit Television (CCTV)

-

-

-

... More
Camera for General Area - Dome - Supply, Installation, testing and commissioning of IP based 3.6 mm fixed lens, 2MP resolution, H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge.

94

-

-

... More
Camera for Lift - Dome - Supply, Installation, testing and commissioning of IP based 2.8 mm fixed lens, 2MP resolution, H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet).

8

-

-

... More
Camera for Corridor - Dome - Supply, Installation, testing and commissioning of IP based 2.8/3.6 mm to 9/12 mm verifocal lens, 2MP resolution, H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet).

19

-

-

... More
Camera - Bullet - Supply, Installation,testing and commissioning of Varifocal Bullet Camera with 2 MP, H.264 / H.265, built-in IR LED, 2.8/3.6 mm to 9/12 mm, 20 to 30 meters IR range, IP 66 with all connectors and necessary accessories for mounting in false ceiling/True Ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet).

14

-

-

... More
Network Video Recorder with Storage: Supply, installation, testing and commissioning of Channel Network Video Recorder with Recording Storage space server for 30 days, Supports 64 channels 720 P resolution video recording at real time, NVR ONVIF supporting, Recording resolution of Max 4 MP, should support dual video HDMI output, H.265,H.264 at real time. Video storage expansion for recording for complete installation with all accessories as required and directed by engineer in charge. (Consider the sufficient HDDs for 720p @ 20 FPS for 30 days continues recording for all channels). Storage calculation details shall be submitted

3

-

-

... More
LED Display - Supply, installation, testing and commissioning of 43 inch full HD LED display for video wall arrangement for 24 x 7 Setup including necessary connection, HDMI cable, rating tray etc. as required for complete installation with all accessories as required and directed by engineer in charge.

4

-

-

... More
Supply, installation, testing and commissioning of workstation with Intel I5 or above, 4 GB ram and 2 TB HDD with software for CCTV integration

2

-

-

... More
Active Components, Racks and Accessories

-

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6, shuttered type, 24 port fully loaded patch panel with necessary cable manager for routing the cable inside rack with all accessories required for complete installation as required as directed by the engineer in charge.

27

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6, 8 port 10/100/1000 Mbps, layer 2, POE, switch with rack mounting brackets, input connector shall be as per IEC-320-C14 with all accessories required for complete installation populated with 1G single SFP module for uplink as required as directed by the engineer in charge. The switch should be capable to provide sufficient power budget to IP cameras as per the requirement.

1

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6, 16 port 10/100/1000 Mbps, layer 2, POE, switch with rack mounting brackets, input connector shall be as per IEC-320-C14 with all accessories required for complete installation populated with 1G single SFP module for uplink as required as directed by the engineer in charge. The switch should be capable to provide sufficient power budget to IP cameras as per the requirement.

6

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6, 24 port 10/100/1000 Mbps, layer 2, POE, switch with rack mounting brackets, input connector shall be as per IEC-320-C14 with all accessories required for complete installation populated with 1G single SFP module for uplink as required as directed by the engineer in charge. The switch should be capable to provide sufficient power budget to IP cameras as per the requirement

19

-

-

... More
Supply, Installation, Testing and commissioning of 6 port Light Interface Unit (LIU) / Fibre Patch Panel, rack mountable with mounting brackets, loaded with Adaptors, Couplers Single Mode (SM) pigtails with splicing with all accessories required for complete installation as required as directed by the engineer in charge

9

-

-

... More
Supply, Installation, Testing and commissioning of 12 port Light Interface Unit (LIU) / Fiber Patch Panel, rack mountable with mounting brackets, loaded with Adaptors, Couplers Single Mode (SM) pigtails with splicing with all accessories required for complete installation as required as directed by the engineer in charge

5

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6, 24 port Layer 3 Managable Core switch with rack mounting brackets, input connector shall be as per IEC-320-C14 with all accessories required for complete installation populated with 1G single SFP module as required as directed by the engineer in charge

1

-

-

... More
Supply, installation, testing and commissioning of 4U Rack with Front glass door, Rear Perforated door with handle Lock & key. Front/Rear 4U mounting angles, top, bottom open, RAL 9005, including necesary exhaust/circulation fan with all accessories required for complete installation as directed by the engineer in charge.

1

-

-

... More
Supply, installation, testing and commissioing of 6U Rack with Front glass door, Rear Perforated door with handle Lock & key. Front/Rear 6U mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan with all accessories required for complete installation as directed by the engineer in charge.

3

-

-

... More
Supply, installation, testing and commissioning of 9U Rack with Front glass door, Rear Perforated door with handle Lock & key. Front/Rear 9U mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan with all other accessories required for complete installation as directed by the engineer in charge

4

-

-

... More
Supply, installation, testing and commissioning of 12U Rack with Front glass door, Rear Perforated door with handle Lock & key. Front/Rear 12U mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan with all other accessories required for complete installation as directed by the engineer in charge.

4

-

-

... More
Supply, installation, testing and commissioning of 16U Rack with Front glass door, Rear Perforated door with handle Lock & key. Front/Rear 16U mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan with all other accessories required for complete installation as directed by the engineer in charge.

1

-

-

... More
Supply, installation, testing and commissioning of 42U Rack DK_PS frame with Front glass door, Rear Perforated door with handle Lock & key, castors. Side and rear panels, Front / Rear 42U 800Wx1000D MM mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan with all other accessories required for complete installation as directed by the engineer in charge.

2

-

-

... More
Supply of Perforated Cable tray with horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr 100 mm width x 60mm Height

1255

-

-

... More
Supply of Perforated Cable tray with horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr 150 mm width x 60mm Height

308

-

-

... More
Supply of Perforated Cable tray with horizontal & vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanised for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The perforated tray shall be supplied with the standard length of 3 Mtr (For Data, Voice, CCTV & PA) 200 mm width x 60mm Height .

77

-

-

... More
Access Control System (ACS)

-

-

-

... More
Supply, Installation, Testing & commissioning of proximity card readers

6

-

-

... More
Supply, Installation, Testing & Commissioning of IP Based 2 Door Controller with minimum 2 Readers, 8inputs, and 4 Relay outputs with enclosure, power supply and all the necessary accessories

6

-

-

... More
Supply, Installation, Testing & commissioning of 600 lbs single door EM Lock with all necessary accessories.

6

-

-

... More
Supply, Installation, Testing & Commissioning of Access control system Software for managing access control system

1

-

-

... More
Supply, fixing, fluke testing and commissioning of exit switch with Faceplate, suitable PVC / GI Modular Back Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

6

-

-

... More
Supply, fixing, fluke testing and commissioning of break glass with Faceplate, suitable PVC / GI Modular Back Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

6

-

-

... More
Supplying and drawing of 2C X 1Sqmm Multistranded Copper Cable for Controller to Exit Switch through surface / recessed medium class PVC conduit through wall/tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

240

-

-

... More
Supplying and drawing of 8C X 1Sqmm Multistranded Copper Cable for Controller to Reader through surface / recessed medium class PVC conduit through wall/tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

120

-

-

... More
Supplying and drawing of 4C X 1Sqmm Multistranded copper cable for Controller to EM Lock through surface / recessed medium class PVC conduit through wall/tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

120

-

-

... More
Public Addressing System

-

-

-

... More
Speaker Cable - Supply and drawing of 2 Core, Twin Twisted, ATC tinned copper, overall sheathed, Armoured Speaker cable, 16 AWG for speakers through surface / Tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

7855

-

-

... More
Audio / Video player - Supply, installation, testing & commissioning of Audio/Video player with USB option with all accessories like jacks and codes for complete installation as required as directed by the Engineer in charge.

1

-

-

... More
Call Stations - Supply, fixing, testing and commissioning of 6 Zone Calling Station with mic as per the drawing as required for complete installation.

1

-

-

... More
Controller - Supply, fixing, testing and commissioning of Master zone controller with routing zone capacity of additional 6 zones with all accessories and necessary connections including necessary cables and jacks as required for complete installation. The work also include integration with Fire Alarm System (FAS) including to play the pre recorded message in case of fire and evacuation.

1

-

-

... More
Power Amplifier - Supply, fixing, testing and commissioning of Power Amplifier of 480 Watts with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.

8

-

-

... More
Power Amplifier - Supply, fixing, testing and commissioning of Power Amplifier of 240 Watts with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.

4

-

-

... More
Mixing Amplifier - Supply, fixing, testing and commissioning of 240 Watts Mixer Amplifier with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.

1

-

-

... More
Wall Mounted Speaker - Supply, fixing, testing and commissioning of Cabinet Speakers with inbuilt line matching transformer with power 12W with a volume controller to adjust the volume individually as per the requirement with all accessories for complete instllation as required. The volume controller shall be fixed speratly as per the site condition for individual control. Cost inclusive of necessary interconnection including conduit, connection wire etc required for complete installation.

172

-

-

... More
Ceiling Mounted Speaker - Supply, fixing, testing and commissioning of ceiling mount Metal Grille Speakers with inbuilt line matching transformer with power 6W with required accessories for installation as required.

427

-

-

... More
Fire Protection System Fire Pump_Control Panel and Pump room Pipe

-

-

-

... More
MAIN PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Hydrant Pump Set: Electrical Driven, Capacity: 2850 LPM at 95 Meter Head, conforming to IS 1520,with Bronze Impeller, S. S. Shaft, Mechanical Seal, High Efficient IE-3 rated Squirrel Cage Induction Electric Motor, Suitable HP, 3Ph, 50 Hz, Suitable RPM, TEFC confirming to IS-325, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts,compound gauge, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per Prevailing Rules, Standards, Requirement and Site Conditions.

1

-

-

... More
SPRINKLER PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Sprinkler Pump Set: Electrical Driven, Capacity: 2850 LPM at 95 Meter Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, High Efficient IE-3 rated, Squirrel Cage Induction Electric Motor, Suitable HP, 3Ph, 50 Hz,Suitable RPM, TEFC confirming to IS-325, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. , Prevailing Rules, Standards, Requirement and Site conditions.

1

-

-

... More
DIESEL PUMP - Supply, installation, testing and commissioning of Stand By / Back Up Fire Pump,Horizontal long coupled, End Suction Pump, Engine Driven, suitable for Automatic operation and consisting of the following and complete in all respect as required; Capacity: 2850 LPM at 95 Meter Head conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, coupled to High Efficient Radiator Cooled Diesel Engine, Suitable HP, Suitable RPM, and with Control Panel with Auto Starting Facility, by activation of concerned Pressure Switch and thro. 12V/24 V Electric Starter, Battery of adequate rating and with Battery Charger, Battery Leads, Diesel Tank for 6 hrs operation, exhaust pipe extended up to rooftop of highest building nearby as per CPCB norms, duly insulated with 50 mm thick rockwool with 1.0 mm thick aluminium sheet cladding, expansion bellows,residential silencer, instruments and protection as per specification, complete with necessary civil foundation, foundation bolts, compound gauge, pressure relief valve, and all other necessary fixing accessories, all as per Technical Specifications.

1

-

-

... More
JOCKEY PUMP - Supply, installation, testing and commissioning of Jockey Pump: Electrical Driven,Capacity: 180 LPM at 101 Mtrs. Head, Vertical Multi Stage Inline Pump with S.S Impeller, Mechanical Seal conforming to IS 1520, and with High Efficient IE-3 Rated Squirrel Gauge Induction Motor, Suitable HP, 3Ph, 50 Hz, Suitable RPM, TEFC confirming to IS-325, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

2

-

-

... More
Supply, erection, commissioning of additional length of Exhaust Pipes with long radius bend from silencer with necessary clamps, fixtures, civil works and thermal insulation with 50 mm thick rock wool and with 1.0 mm thick aluminum sheet cladding of following adequate size including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. The horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe of required height shall be provided according to latest CPCB norms

60

-

-

... More
MOTOR CONTROL PANEL - Fabrication, supply, erection, testing and commissioning of cubicle type,dust and vermin proof, floor mounted, front operated Common Control Panels for Main Fire Pumps & Jockey Pumps, made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates (top entry) made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. The panel shall be IP: 54 protection, complete with Main Isolator, Bus Bar Chamber, Volt Meter, Ammeter, Individual Star- Dealt Starters for Main Pumps, DOL Starter for Jockey Pump, Contactors, Auxiliary Contacts, Timers for automatic operation and to avoid freequent re-starts, Indicating Lamps, Fuses, Auto / Manual Selector Switches for all Fire Pumps, Manual On / Off Buttons for Jockey Pump & Manual On Buttons for Main Pumps, all internal wiring etc. The price for Control Panel shall be inclusive of, Control Cabling, in Steel Conduits, for automatic starting of Main Pumps & Automatic start and stop for Jockey Pump and Earthing of the Panel, all as per Technical Specifications, Schematic Drawing, Prevailing Rules, Standards, Requirement and Site Conditions. The Panel shall be to the approval of Kerala State Electrical Inspectorate. "Main Fire Pump - 1 No. Sprinkler Pump - 1 No. Jockey Pump - 2 Nos. " Incomer - 630A, FP, Switch Disconnector (Trip Free Switch) 1-No. 630A, 415V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh Class B + C / Class 1 + 2 Surge arrestor device with necessary MCCB for protection of same - 1 Set. RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoing 250A, TP+NL, Switch Disconnector + Star delta starter with all accessories Without overload relays / protection - 2 Set. 32A, TP+NL, MCCB Isolator + DOL Starter with all accessories with overload realy and single phase preventor - 2 Set.

1

-

-

... More
Providing, fixing, pressure testing and commissioning of Fire Line Pipe Work for Fire Pump Room, as per the Tender Drawings, with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty But Welded Fittings (confirming to IS:1239) Part - II,such as tees, elbows, reducers, check nuts, unions, flanges, nipples, neoprene gaskets, bolts, nuts,washers etc. including cutting, threading, welding, joining etc. by using suitable and strong enough supports, as per requirement, providing Puddle Flanges, higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound /sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per Technical Specification to the approval of the Engineer - in - charge and Consultant. Dia - 250mm - Suction Lines, Suction Header & Delivery Header, Puddle Flanges, Vortex Plates, including all connection accessories, Elbows connection Tess etc., all as per Tender Drawings.

32

-

-

... More
Providing, fixing, pressure testing and commissioning of Fire Line Pipe Work for Fire Pump Room, as per the Tender Drawings, with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty But Welded Fittings (confirming to IS:1239) Part - II,such as tees, elbows, reducers, check nuts, unions, flanges, nipples, neoprene gaskets, bolts, nuts,washers etc. including cutting, threading, welding, joining etc. by using suitable and strong enough supports, as per requirement, providing Puddle Flanges, higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound /sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system Dia - 200mm - Puddle Flange and Connection Pieces for Suction Lines for Fire Pumps.

25

-

-

... More
Providing, fixing, pressure testing and commissioning of Fire Line Pipe Work for Fire Pump Room, as per the Tender Drawings, with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty But Welded Fittings (confirming to IS:1239) Part - II,such as tees, elbows, reducers, check nuts, unions, flanges, nipples, neoprene gaskets, bolts, nuts,washers etc. including cutting, threading, welding, joining etc. by using suitable and strong enough supports, as per requirement, providing Puddle Flanges, higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound /sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system. Dia - 150mm - Delivery Line for Main Fire Pumps with Fabricated Connection Pieces / Accessories

14

-

-

... More
Providing, fixing, pressure testing and commissioning of Fire Line Pipe Work for Fire Pump Room, as per the Tender Drawings, with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty But Welded Fittings (confirming to IS:1239) Part - II,such as tees, elbows, reducers, check nuts, unions, flanges, nipples, neoprene gaskets, bolts, nuts,washers etc. including cutting, threading, welding, joining etc. by using suitable and strong enough supports, as per requirement, providing Puddle Flanges, higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound /sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system.. Dia - 100mm - Test / Drain Line with Puddle Flange for Pump Room

5

-

-

... More
Providing, fixing, pressure testing and commissioning of Fire Line Pipe Work for Fire Pump Room, as per the Tender Drawings, with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty But Welded Fittings (confirming to IS:1239) Part - II,such as tees, elbows, reducers, check nuts, unions, flanges, nipples, neoprene gaskets, bolts, nuts,washers etc. including cutting, threading, welding, joining etc. by using suitable and strong enough supports, as per requirement, providing Puddle Flanges, higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound /sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system. brDia - 65mm - Suction Line for Jockey Pumps with Fabricated Connection Pieces / Accessories

5

-

-

... More
Providing, fixing, pressure testing and commissioning of Fire Line Pipe Work for Fire Pump Room, as per the Tender Drawings, with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty But Welded Fittings (confirming to IS:1239) Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples, neoprene gaskets, bolts, nuts, washers etc. including cutting, threading, welding, joining etc. by using suitable and strong enough supports, as per requirement, providing Puddle Flanges, higher sizes of Sleeves / Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system. Dia - 50mm - Delivery Line for Jockey Pumps with Fabricated Connection Pieces / Accessories

12

-

-

... More
Hydrant System_Fire Pipes Valves and Accessories

-

-

-

... More
Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Heavy Duty Ductile Iron Grooved Fittings, for pipes above 50mm. dia, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with Two Coats of approved 2 Pack Epoxy Zinc Phosphate Primer and Two Coats of Compatible Fire Red Enamel Top Coat Painting System. All Pipe Fittings shall be UL Listed and FM Approved Dia - 150mm

1764

-

-

... More
Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Heavy Duty Ductile Iron Grooved Fittings, for pipes above 50mm. dia, such as tees, elbows, reducers, check nuts,unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading,grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with Two Coats of approved 2 Pack Epoxy Zinc Phosphate Primer and Two Coats of Compatible Fire Red Enamel Top Coat Painting System. All Pipe Fittings shall be UL Listed and FM Approved. Dia - 100mm

90

-

-

... More
Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Heavy Duty Ductile Iron Grooved Fittings, for pipes above 50mm. dia, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading,grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with Two Coats of approved 2 Pack Epoxy Zinc Phosphate Primer and Two Coats of Compatible Fire Red Enamel Top Coat Painting System, . All Pipe Fittings shall be UL Listed and FM Approved. Dia - 80mm

198

-

-

... More
Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Heavy Duty Ductile Iron Grooved Fittings, for pipes above 50mm. dia, such as tees, elbows, reducers, check nuts,unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading,grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with Two Coats of approved 2 Pack Epoxy Zinc Phosphate Primer and Two Coats of Compatible Fire Red Enamel Top Coat Painting System. All Pipe Fittings shall be UL Listed and FM Approved. Dia - 65mm

354

-

-

... More
Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Heavy Duty Ductile Iron Grooved Fittings, for pipes above 50mm. dia, such as tees, elbows, reducers, check nuts,unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading,grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with Two Coats of approved 2 Pack Epoxy Zinc Phosphate Primer and Two Coats of Compatible Fire Red Enamel Top Coat Painting System. All Pipe Fittings shall be UL Listed and FM Approved. Dia - 50mm

1098

-

-

... More
Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Heavy Duty Ductile Iron Grooved Fittings, for pipes above 50mm. dia, such as tees, elbows, reducers, check nuts,unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading,grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with Two Coats of approved 2 Pack Epoxy Zinc Phosphate Primer and Two Coats of Compatible Fire Red Enamel Top Coat Painting System. All Pipe Fittings shall be UL Listed and FM Approved. Dia- 40mm

2166

-

-

... More
Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Heavy Duty Ductile Iron Grooved Fittings, for pipes above 50mm. dia, such as tees, elbows, reducers, check nuts,unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading,grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with Two Coats of approved 2 Pack Epoxy Zinc Phosphate Primer and Two Coats of Compatible Fire Red Enamel Top Coat Painting System. All Pipe Fittings shall be UL Listed and FM Approved. Dia- 32mm

972

-

-

... More
Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589 / 1239 Part - I (wherever applicable) and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Heavy Duty Ductile Iron Grooved Fittings, for pipes above 50mm. dia, such as tees, elbows, reducers, check nuts,unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with Two Coats of approved 2 Pack Epoxy Zinc Phosphate Primer and Two Coats of Compatible Fire Red Enamel Top Coat Painting System, all as per Technical Specifications. All Pipe Fittings shall be UL Listed and FM Approved, as per Technical Specifications Dia- 25mm

5688

-

-

... More
"Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8239 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer’s technical details. i. Internal lining with Cement Mortar ii. External Coating with a layer of metallic zinc + a layer of and bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall be inclusive of earthwork excavation and providing Masonary / PCC / RCC Thrust Blocks as per requirement." Dia - 150mm

871

-

-

... More
"Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8239 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and manufacturer’s technical details. i. Internal lining with Cement Mortar ii. External Coating with a layer of metallic zinc + a layer of and bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall be inclusive of earthwork excavation and providing Masonary / PCC / RCC Thrust Blocks as per requirement." Dia - 100mm

817

-

-

... More
Supplying, installing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16,conforming to IS: 5312 with required companion flanges nuts, bolts etc. complete. Dia - 250mm

1

-

-

... More
Supplying, installing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16,conforming to IS: 5312 with required companion flanges nuts, bolts etc. complete. Dia - 150mm

4

-

-

... More
Supplying, installing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16,conforming to IS: 5312 with required companion flanges nuts, bolts etc. complete. Dia - 65mm

2

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar,Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 250mm

1

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar,Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 200mm

4

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar,Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 150mm

35

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar,Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 100mm

1

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 80mm

1

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar,Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 65mm

2

-

-

... More
Providing, fixing, testing and commissioning of Ball Valve, PN-16 Forged Brass & Nickel / Chrome Plated,conforming to IS: 9890, UL Listed and FM approved with Screwed Female Ends to BS:21, and with noncorrosive handle / lever, including necessary accessories and connections. Dia - 50mm

24

-

-

... More
Providing, fixing, testing and commissioning of Ball Valve, PN-16 Forged Brass & Nickel / Chrome Plated,conforming to IS: 9890, UL Listed and FM approved with Screwed Female Ends to BS:21, and with noncorrosive handle / lever, including necessary accessories and connections. Dia - 25mm

40

-

-

... More
Providing, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh, suitable flanges,nuts, bolts, gaskets etc. complete. Dia - 250mm

2

-

-

... More
Providing, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh, suitable flanges,nuts, bolts, gaskets etc. complete. Dia - 200mm

1

-

-

... More
Providing, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh, suitable flanges,nuts, bolts, gaskets etc. complete. Dia - 150mm

2

-

-

... More
Providing, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh, suitable flanges,nuts, bolts, gaskets etc. complete. Dia - 65mm

2

-

-

... More
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12,Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 250mm

2

-

-

... More
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12,Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and withn required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 200mm

3

-

-

... More
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12,Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and withquired flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 150mm

1

-

-

... More
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12,Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 100 mm

6

-

-

... More
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12,Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 80 mm

3

-

-

... More
Supply, installation, testing and commissioning of Pressure Switches with pressure rating 4 to 14 Bar with a differential of 0.2 to 1.6 Bar (however; should be suitable for Fire Pumps) and with ¼” BSP (F) inlet connection and screwed cable entry for fixing cable gland. It shall also be complete with Stainless Steel Isolation Cock, Nipples, tail, connecting pipes etc.

5

-

-

... More
Supply, installation, testing and commissioning of 4" dia. Bourdon Type Pressure Gauge, with ISI Mark or of equivalent International Standards. Weather / Water Proof Type, Pressure Range: 0 to 16 Bar, with Stainless Steel Shut off Cock, Syphone Pipe, Snubber etc.

3

-

-

... More
"AIR CUSHION VESSEL Supplying, Installation, Testing & Commissioning of air cushion tank (air vessel) of continuous welded construction, fabricated out of at least 8mm thick steel with dished ends,and supporting legs, Capable of carrying 16Bar Pressure, 250mm dia & 1200mm high complete with necessary air release valve, safety valve, pressure gauge, flange connection to the wet riser piping with necessary piping to meet the functional requirement of the system.

2

-

-

... More
Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark,Stainless Steel-304 body with 63mm. oblique instantaneous single outlet, 75mm. N.B. flanged inlet,Stainless Steel -304 spindle, complete with PVC blank cap, G.I. chain etc.

74

-

-

... More
Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided /rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm dia isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set

44

-

-

... More
Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fiber. conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg/Cm2 and Burst Pressure 38 Kg/Cm2. The Fire Hose shall be with IS: 636 Type-A marking and 63mm.dia.x15Mtr.long with pair of 63mm. male and female instantaneous couplings, Stainless steel-304, having IS: 903 mark and duly S. S. wire wounded. The hose shall be rolled and hung to suitable M. S. support in the Fire Station.

148

-

-

... More
Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark.

74

-

-

... More
Supplying, installing and commissioning of fire brigade inlet, inlet connection of 4 way with 4 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main as well as to Fire water tank. Qouted rate shall be included with M.S. cabinet (painted - inside and outside) of suitable size with mounting supports etc. complete

2

-

-

... More
Supply, installation, testing and commissioning of Fire Brigade Draw Off Outlet C.I. body, having 3 Gunmetal, 63mm. female instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 3 nos. of rubber blank caps and G.I. chains.

1

-

-

... More
Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement.

44

-

-

... More
Supply and fix at site in position Weather proof Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door,with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement

30

-

-

... More
Providing and fixing sight glass assembly of brass body and brass ball with chrome plated, steel handle,PN16 or above, UL Listed & FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems with grooved end connection ends. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass.

40

-

-

... More
Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including isolation valve and necessary accessories and connections.

8

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage, Standard Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge,with necessary accessories and fittings. Pendant type - 68 / 79 Degree C Rating

2134

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage, Standard Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge,with necessary accessories and fittings. Upright type - 68 / 79 Degree C Rating

811

-

-

... More
Supply, installation, testing and commissioning of Hydraulically Operated Fire Sprinkler Alarm Valve (Installation Control Valve), Flanged / Grooved Ends (as per final requirement without any cost variation).complete with Constant Pressure Trim Assembly, Water Motor Gong, Control Valves, Pressure Switch,Pressure Gauges etc. Including all necessary fixing accessories, all as per Technical Specifications. The control cabling from Pressure Switches to concerned Monitor Module shall be measured with proposed Fire Alarm System. The Alarm Valve and the Total Parts / Components / Accessories shall be UL Listed /FM approved. Dia - 200mm

1

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 16 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System., all as per Technical Specifications. The control cabling from flow switches to concerned Module shall be measured with proposed Fire Alarm System. Dia - 150mm

19

-

-

... More
Providing, Fixing, Testing and Commission Flexible Sprinkler Hose of adequate size; UL Listed, FM Approved, 25mm. (1") BSP Male Inlet, 15mm. (1/2") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, length: 1500 mm, and with all connecting systems and accessories.

2134

-

-

... More
Providing & Fixing 2 Piece Chrome Plated Friction Fit recessed escutcheon for pendant sprinklers, as per requirement

2134

-

-

... More
Intelligent Addressable Fire Alarm System

-

-

-

... More
Supply, install, test and commission Intelligent Addressable Fire Alarm Control Panel (MCP) as per the technical specification and not limited to having Visual Display Unit (VDU) preferably 640 character LCD display with Battery Back up for 24 hours for normal operation and 1 hours on alarm condition. The control panel, battery charger etc, shall be UL listed approved. The panel / panels should be equipped with Loop Cards of adequate capacity as per manufacturer reccomendation to incorporate the devices and detectors for this project considering 20% spare capacity in each loop. The panels shall be networked together (in case of more than a panel) and capable of networking with other compatible panels. The panel should be expandable to add another Loop card.

2

-

-

... More
Supply, installation, testing and commission Intelligent Addressable Network Repeater Panel (NRP) with minimum Color display, capable of mapping all monitoring devices/detectors on Fire Alarm Network. This NRP shall act as an independent node communicating on the peer to peer network and shall not be dependent on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of NRP operation. The Unit shall be complete in all respect and the Cost of Panel shall inclusive of Network Communication Module(s) (NCM), for networking with the Main Fire Alarm Panels.

1

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Multi Sensor Detectors. The detectors shall have multiple sensitivity (adjustable at site) levels, programmable for timed automatic sensitivity selection complete with Standard Base, junction box and other accessories as required. Detectors shall be UL listed and FM Approved.

1212

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Heat Detector and with rate of rise of temperature feature, programmable for timed automatic sensitivity selection with Standard Base, junction box and other accessories. Detectors shall be UL listed.

5

-

-

... More
Providing, fixing test and commission Intelligent Addressable Manual Call Station Point with addressable module that monitors and reports contact status, etc

82

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Weather / Water Proof / Corrosion Resistant type Manual Call Point having an integrally mounted addressable module that monitors and reports contact status, IP67 rated, complete

2

-

-

... More
Providing, fixing, test and commission Conventional Type Horn/Strobe rated at 82 dB @3Mtr. for audible annunciation and 75Candela flashing at 1Hz. for visual indication.

113

-

-

... More
Providing, fixing, testing and commission Intelligent Addressable Input / Monitor Module, for interface with Flow Switches, Fire Pumps, Supervisory Switches, Alarm Valve, Water Tank Level etc.

53

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Control Module, for interface with Fire Alarm Annunciating System, Lift Panels, Public Address System etc.

38

-

-

... More
Providing, fixing,, test and commission Intelligent Addressable Relay Module, for interface with AHUs,Ventilation System, Smoke Management System, LPG System, Power Distribution etc. (This quantity shall be tentative / approximate only, shall change as per final design of the other systems and final requirement)

16

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected, all as per technical specifications.

67

-

-

... More
Supply, laying, testing and commissioning o 2Core x 1.5 mm2 FRLS Armoured Cables with Red Colour /Finish.

22011

-

-

... More
Fire Extinguishers

-

-

-

... More
Supply, installation, testing & commissioning of Portable Fire Extinguisher as per BIS 2190 and IS:15683:2018 and with relevant ISI Stamping/Marking. ABC Dry Chemical Store Pressure Type - 4 kg

39

-

-

... More
Supply, installation, testing & commissioning of Portable Fire Extinguisher as per BIS 2190 and IS:15683:2018 and with relevant ISI Stamping/Marking. ABC Dry Chemical Store Pressure Type -2kG

118

-

-

... More
"Clean Agent Modular Type Ceiling mounted Fire Extinguisher 5 Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with Charge of Clean agent (Gas) is also known as HFC Blend A, It is a blend of Hydro Fluoro carbon and organic detossificant essence P26. The sprinkler body will comprise of temperature sensitive quartsoid bulb of temperature rating of 680. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling. The Extinguisher shall be externally epoxy powder coated as per IS: 5 Color Shade No. 538 (For Server room)" 5Kgs

22

-

-

... More
Fire Signages

-

-

-

... More
Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.25cm height letters in red with white back ground.The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points.

94

-

-

... More
Floor identification signage ( ie, GROUND FLOOR, FIRST FLOOR, etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 cm with contrasting colour from back ground.Size shall be 15cm x 30cm.

44

-

-

... More
Floor identification signage ( ie, GROUND FLOOR, FIRST FLOOR, etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 cm with contrasting colour from back ground.Size shall be 15cm x 30cm.

88

-

-

... More
Providing and fixing in position the signage " FIRE ORDER" on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2' x 3'.

94

-

-

... More
Providing and fixing in position the signages " Fire Hydrant Chamber" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2' x 3'.

70

-

-

... More
Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size:300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red /Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum), with 4 Hr. Battery Backup. Single Side Display

90

-

-

... More
Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size:300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red /Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum), with 4 Hr. Battery Backup. 'Double Side Display

24

-

-

... More
Miscellaneous Items

-

-

-

... More
FIRE SEALANT for Fire and ELV Shafts - Supply and Fixing of load bearing Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1 g/l as per LEED 2009. Firestop installation should be done by trained applicators (HAFSC) and in accordance with manufacturer's guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemical anchoring along the length and breadh of the shaft and provide 2 layers of chicken mesh etc. The mortar shall be applied with a minimum thickness of 65 mm & having load bearing capacity of 200kg/sqm. Proper engineering judgement needs to be submitted through the manufacturer. Complete installation report through Software CFS DM shall also be submitted for inspection purpose.

195

-

-

... More
Supply, fabrication at site and fixing of dual Chequered plates-6mm with rock wool insulation stacked in between chequered plates for thermal insulation, in HVAC ducting, chilled water piping and internal plumbing shafts ,the work also includes make cut outs for such services including closing the gap with intumescent seal. The thickness of rock wool shall be suitable to slab thickness(100-125mm).All accessories including Angle iron supports to bear the load(100 kg) of the above arrangement shall be provided.

125

-

-

... More
Talkback System

-

-

-

... More
Supply, installation, testing & commisioning of automatic control console of 8 zones micro process based complete with floor to floor announcing and talk back facilities with the following features and made functional: (a) Feather type key pads to select the zones. (b) Moulded plastic attractive enclosure. (c )Backlight Liquid Crystal Display(LCD) (d) User friendly interactive display. (e) Announcement selector - PH Switch. (f) Listen selector switch. (g) All Call switch to select all zones simultaneously for announcement (h) Zones Call Display On the LCD With Audio Alarm. Panel to be installed in the Fire

1

-

-

... More
Controller Unit with 120 W amplifier, Goose neck type microphone and with the following features: (i) Built in Power supply. (ii) Zone Selector switching Circuit (iii)Terminal blocks to terminate zones wires,amplifier wires etc., (iv) Zone Call processing Circuit etc and made functional. Panel to be installed in the Fire Control Room.

1

-

-

... More
Supply, installation, testing and commisioning of Public Address speaker with talk back facility 6 Watts with L M T and call switch, made out of powder coated CRCA sheet, wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting.

82

-

-

... More
Supply, Installation, Testing and Commissioning of FRLS 2CX1.5mm SQmm Armoured cable.

4200

-

-

... More
Heating Ventilation & Air-Conditioning (HVAC) Works Water Chilling Plant

-

-

-

... More
Supply at site including local transport with full cover insurance, fire or any other contingencies, unload,store, handle, erect, balance, test and commission the entire water chilling plant as per specifications including all accessories as specified for water chilling plant. WATER COOLED TWIN SCREW CHILLER- (R-134A/410) EACH WITH SEMI SEALED / SEALED, SINGLE / MULTIPLE COMPRESSOR OF MINIMUM CAPACITY 150 TR. Minimum Overall Chiller efficiency offered shall have COP 5.8 AS PER ECBC + Buildings 2017/ ASHRAE / ARI 550/590 & IPLV 7.1. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F Comprising of Screw Compressor as per specifications. Drive motors of suitable ratings 415+/- 10% Volts 50 Hz AC supply and starter panel with VFD starter. Water cooled condenser with all accessories. Automatic capacity control unit to regulate the capacity down to 25%. Micro-processor control panel. Building management system compatible software Data Link / MicroGateway for integration with third -party BMS on Modbus / BACNET protocol, Safety controls as per spec. wiring and interlock between pumps shall be included in the chiller cost. The cost for additional incoming metering panel for each chiller to be included in the chiller." "Water cooled chiller with all accessories: LOT-integral mounting frame for all the components, LOT refrigerant piping & valves, LOT-insulation of chiller and suction line, LOT-first charge of refrigerant and lube oil, LOT-vibration isolation pads. LOT-Thermometer for water inlet and outlet and water flow switches. MCCB's as a part of the chiller. Copper cable & isolators for chiller to be included in the chiller cost. Isolators at the incoming side including capacitor power supply and earthing will be terminated by other agencies. Power supply and earthing will be terminated in the isolator by other agencies. R.C.C foundation along with PCC/RCC sub base with fixing of foundation bolts and nuts, spring mounts and finishing the slabs as well as openings and finishing of civil structures.

3

-

-

... More
Pumps and Cooiling Tower

-

-

-

... More
Supply, installation, testing & commissioning the chilled water primary pumps asper specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Pump efficiency shall be as per ECBC + Buildings 2017. Capacity : 360 USgpm, 1440 RPM (Suggested) Head : 45 feet Motor, IE 3

4

-

-

... More
Supply, installation, testing & commissioning the chilled water secondary pumps as per specificationincluding all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Pump efficiency shall be as per ECBC + Buildings 2017. Capacity :360 USgpm, 1440 RPM (Suggested) Head : 80 feet Motor, IE 3

4

-

-

... More
Supply, Installation, testing & commissioning the condenser water pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Pump efficiency shall be as per ECBC + Buildings 2017. Capacity : 600 USgpm, 1440 RPM (Suggested) Head : 70 feet Motor, IE 3

4

-

-

... More
Supply, Installation, testing & commissioning the cooling towers as per specification including all accessories as specified and as required. COOLING TOWERS of actual capacity complete in all respects as per technical specifications and equipment schedule complete with FRP casing, FRP fan cylinder, PVC louvers, PVC drift eliminator polypropelene nozzles, drive assembly, HDG fan guard/bird screen, non-clogging nozzle type water distribution system. PVC fill, aluminium ladder with railings, make up water, quick fill, drain over flow connections etc. as per specifications. Including R.C.C foundation along with PCC/RCC sub base, fixing with bolts and nuts and finishing the slabs or any opening etc. 150 TR - CTI/JCI approved induced draft, cross flow cooling tower with vertical air\ discharge. EWT = 97.5 degree F LWT = 90 degree F WET bulb = 82 degree F Flow rate = 600 USgpm Fan Motor: IE 3, suitable 3 Motor, VFD Driven

3

-

-

... More
"Supply, Installation, Testing & commissioning of Variable Frequency Drive complete IP 20 VSPS control panel (IP 55 if panel is to be installed under open air) consisting of adjustable frequency drive (AFD) for each pump, one dedicated microprocessor based pump controller per zone housed within this enclosure panel with parallel pumping software duly down loaded and single / multiple differential pressure sensor / transmitters as per the site requirement. The entire system along with secondary pumps as described above must be sourced from single manufacturer only, to ensure unit responsibility. The VFD should be incorporated with RFI (radio frequency interface) filters which can control THDi [Total Harmonic Distortion Current] below 5%, auto bypass starter compactable to the third party bms"

1

-

-

... More
Double Skin Air -Handling Units with VFD, Plug Fans and Thermal Break

-

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "27 TR, 10800 cfm, 21.6 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "20 TR, 8000 cfm, 16 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units" "17 TR, 6800 cfm, 13.6 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "16 TR, 6400 cfm, 12.8 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "11 TR, 4400 cfm, 8.8 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFDstarter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "10 TR, 4000 cfm, 8 sqft./ 4row (Double Skin Floor mounted Horizontal AHU)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFDstarter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "9 TR, 3600 cfm, 7.2 sqft./ 6 row (Double Skin Floor mounted Horizontal AHU with mixing Box, 2 x 3 KW Heater)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "8 TR, 3200 cfm, 6.4 sqft./ 6row (Double Skin Floor mounted Horizontal AHU with mixing Box 2 x 3 KW Heater)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drivesanti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks atthe the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "8 TR, 3200 cfm, 6.4 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for isolation rooms/ ICU AHU shall be with UV irradiation units "9 TR, 3600 cfm, 7.2 sqft./ 4row (Double Skin Ceiling Suspended AHU with mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "11 TR, 4400 cfm, 8.8 sqft./ 4row (Double Skin Ceiling Suspended AHU with mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "7 TR, 2800 cfm, 5.6 sqft./ 4row (Double Skin Ceiling Suspended AHU with mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "4 TR, 1600 cfm, 3.2 sqft./ 4row (Double Skin Ceiling Suspended AHU with mixing Box)"

2

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "3 TR, 1200 cfm, 2.4 sqft./ 4row (Double Skin Ceiling Suspended AHU with mixing Box, Fine Filter, 3 KW Heater)"

2

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "24 TR, 9600 cfm, 19.2 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with Fine Filter and mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "21 TR, 8400 cfm, 16.8 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with Fine Filter and mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "20 TR, 8800 cfm, 16 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with Fine Filter, mixing Box, 2 x 3 KW Heater)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "18 TR, 7200 cfm, 14.4 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with Fine filter and mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "17 TR, 6800 cfm, 13.6 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with Fine filter and mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "7 TR, 2800 cfm, 5.6 sqft./ 4 row (Double Skin Floor mounted Horizontal AHU with Fine filter and mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "4 TR, 1600 cfm, 3.2 sqft./ 4 row (Double Skin Floor mounted Horizontal AHU with Fine filter and mixing Box)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD' s shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "8 TR, 3200 cfm, 6.4 sqft./ 8 Row (Double Skin Floor mounted Horizontal AHU with mixing Box, 10 Micron Pre filters, 5 Micron fine filters, heater capacity 2 x 3 KW, Thermal Break)

9

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass mstarter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "11 TR, 4700 cfm, 9.4 sqft./6 Row (Double Skin Floor mounted Horizontal AHU with mixing Box, heater capacity 2 x 3 KW, Fine filter, Thermal Break)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units "7 TR, 4000 cfm, 8 sqft./ 6 Row (Double Skin Floor mounted Horizontal AHU with mixing Box, heater capacity 2 x 3 KW, Fine filter, Thermal Break)"

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specificationincluding all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with bypass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping." "Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. " "Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for: Operation theater AHU's 100 mm Static Cathlab, CT/MRI- 65 mm Static AHU's with fine filters - 55 mm Static all other AHU's - 50 mm Static, for Isolation rooms/ ICU AHU shall be with UV irradiation units 5 TR 2000 CFM 4 sqft / 6 row. (Double Skin Floor mounted Horizontal AHU with mixing Box, heater capacity 2 x 3 KW, Fine filter, Thermal Break

1

-

-

... More
TREATED FRESH AIR UNIT WITH HEAT RECOVERY WHEEL, VFD, SUPPLY & RETURN FANS "Supply at site, including, local transport, unload, store, handle, erect, balance and commission of the entire HRW as per specifications including all accessories as specified and as required. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F Return Air condition: DBT- 75 Deg F , RH– 55% Supply Fan Static - 60 to 70 mm WG Return fan - 40 mm to 60 mm WG Efficiency 80- 85%" "TFA -1 TFA - 28 TR HRW AHU, 10 sq.ft./ 8 Row coil with 5000 CFM Supply fan, 4800 cfm Return fan and Heater coil of 2 x 3 kw"

1

-

-

... More
Fan Coil Units, Split Units and VAV

-

-

-

... More
Fan Coil Units with valve station Supply, installing, testing and commissioning of Fan Coil Units eachcomplete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fansection with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor,extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop,providing and fixing GM ball valve (withSS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 1 TR Hideaway FCU

5

-

-

... More
Fan Coil Units with valve station Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 1.25 TR Hideaway FCU

2

-

-

... More
Fan Coil Units with valve station Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 1.5 TR Hideaway FCU

8

-

-

... More
Fan Coil Units with valve station Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 2 TR Hideaway FCU

24

-

-

... More
Fan Coil Units with valve station Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 2.5 TR Hideaway FCU

1

-

-

... More
Split Unit Supply, installing, testing and commissioning of Split Package air-conditioners each complete with scroll compressor, air cooled condenser, GSS casing, filters, cooling coils, fan motors, insulated copper refrigerant piping as per drawing, control wiring, refrigerant controls and accessories, including Microprocessor control with indication lamps for the operation of the system with thermostat fixed in the respective rooms to adjust the temperature according to the equipment's requirements with micro processor control panel for each machine. Tenders to elaborate the features of Micro-processor\ panel. GI painted frame works for outdoor units & making good of civil works. Including Insulated refrigent piping with 19 mm thick nitrile ruber insulation. 2 TR Hiwall Split Unit

2

-

-

... More
VAV (Variable Air Volume) "Vav unit for supply air for rectangular ducts WITH THERMOSTAT AND CONTROLS Casing and damper blade made of galvanized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 600 cfm

1

-

-

... More
VAV (Variable Air Volume) "Vav unit for supply air for rectangular ducts WITH THERMOSTAT AND CONTROLS Casing and damper blade made of galvanized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 1150 cfm

2

-

-

... More
VAV (Variable Air Volume) "Vav unit for supply air for rectangular ducts WITH THERMOSTAT AND CONTROLS Casing and damper blade made of galvanized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 1800 cfm

1

-

-

... More
VAV (Variable Air Volume) "Vav unit for supply air for rectangular ducts WITH THERMOSTAT AND CONTROLS Casing and damper blade made of galvanized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 2000 cfm

1

-

-

... More
VAV (Variable Air Volume) "Vav unit for supply air for rectangular ducts WITH THERMOSTAT AND CONTROLS Casing and damper blade made of galvanized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. " VAV - 2100 CFM

1

-

-

... More
Chilled Water Piping, Drain Water Piping and Valves

-

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows,reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. 250 mm dia.

20

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. 200 mm dia.

210

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. 150 mm dia

100

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows,reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. 125 mm dia

110

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same." 100 mm dia

120

-

-

... More
"Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same." 80 mm dia

175

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall bebonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same." 65 mm dia

335

-

-

... More
"Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same." 50 mm dia

300

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same." 40 mm

610

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same." 32 mm dia

110

-

-

... More
"Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same." 25 mm dia

300

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre-insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Underground piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with Vcut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same." 20 mm dia

700

-

-

... More
Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection - 250mm dia

70

-

-

... More
Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection. 125 mm dia.

110

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 32 mm dia. PVC

200

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 25 mm dia. PVC

300

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 250 mm dia.

5

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 200 mm dia.

2

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 150 mm dia

2

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 125 mm dia

24

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 100 mm dia.

2

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 80 mm dia.

2

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 65 mm dia.

12

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 50 mm dia

20

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 40 mm dia.

52

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 32 mm dia

21

-

-

... More
Supply, installation, testing & commissioning of the following type forged Ball Valve, PN-20 gunmetal/cast alloy, including all necessary accessories and connections. 25 mm dia

81

-

-

... More
Supply, installation, testing & commissioning of the following Non Return Valves as per the specifications and as required. Non Return valves up to 65mm size shall be of gun metal with screwed female ends. Valves of 65mm and above shall be of CI with flanged ends. PN 16 pressure rating, EPDM seal. Non- Return Valve of size:- 125 mm dia

8

-

-

... More
BALANCING VALVE WITH PROVISION FOR FLOW MEASURMENT: Supply, installation, testing & commissioning of Balancing valve with built in measuring facility, C.I Body with EPDM seal, long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water as specified. Balancing Valve with 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections; Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/-, necessary insulation as per specification. 125 mm dia.

3

-

-

... More
SUCTION GUIDE with strainer: Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required. 125 mm dia.

8

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications in the connected piping and adequately supported as per specifications: 65 mm dia

3

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications in the connected piping and adequately supported as per specifications: 50 mm dia

7

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications in the connected piping and adequately supported as per specifications: 40 mm dia

17

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications in the connected piping and adequately supported as per specifications: 32 mm dia.

4

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications in the connected piping and adequately supported as per specifications: 25 mm dia

5

-

-

... More
PRESSURE GAUGE: Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type made of Stainless steel or cast aluminium case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection : Brass, NPS 12mm dia bottom-outlet type, Dial: Satinfaced, non-reflective aluminium with permanently etched scale markings, Pointer: Red or other darkcolour metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification.

94

-

-

... More
THERMOMETERS: Supply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminium, or brass for thermo well installation and of length to suit installation, Stainless Steel U-Siphon as per specification.

94

-

-

... More
Supply, installation, testing & commissioning of differential pressure switch as per the specifications and as required.

3

-

-

... More
Supply, installation, testing & commissioning of the following motorized cut off valves as per the specifications and as required. Cl Body, minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, capable of accepting upto 10 V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required. 125 mm dia.

3

-

-

... More
500 L Pressurized Tank : Design, supply, installation, testing and commissioning of Pressurised chilled water expansion tank with insulation, Make up connection for closed loop system along with necessary pneumatic devices and accessories and MS 'C' section supports in order to keep chilled water under pressure. The tank shall be precharged steel tank with replaceable heavy duty butyl rubber bladder. The tank shall have 50mm system connection and 20mm drain and charging valve connection to facilitate onsite charging of tank. The tank shall be fitted with lifting rings and floor mounting skirt for vertical installation. The tank shall be constructed according to section 8 of ASME boiler and pressure vessel code and stamped 125psi working pressure. The contractor shall submit calculation regarding the above data. Pumps shall be of N+1 configuration. including with control wiring

1

-

-

... More
"Supply, installation, testing & commissioning of a common air separator on the chilled water return line located at the pump suction and suitable for Secondary pump water flow; the separator shall be complete with high capacity air vent, flanges, service valve, non return valve, isolation butterfly valve for makeup water inlet. Capacity suitable for 1080 USGPM and 250mm NB CHW Header line"

1

-

-

... More
AUTO AIR VENTS: Supply & install of air vents / purge valves at the highest points in chilled water piping complete each floor with pipes nipple welded to pipe, hex nipple, socket, U-pipe connection at outlet of air vent etc. as required.

50

-

-

... More
Supply and fix flexible connections with control rods for pumps and chiller. Size: 125 mm dia."

22

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification 65 mm dia.

3

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification 50 mm dia

7

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification 40 mm dia

17

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification 32 mm dia

4

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compatible Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification 25 mm dia

5

-

-

... More
Condenser Water Piping and Valves

-

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specifications. Opening as good as same. 250 mm dia

260

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specifications. Opening as good as same. 250 mm dia

120

-

-

... More
Supply, installation, testing & commissioning of the following type Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. 150 mm

20

-

-

... More
Supply, installation, testing & commissioning of the following Non Return Valves as per the specifications and as required. Non Return valves up to 65mm size shall be of gun metal with screwed female ends. Valves of 65mm and above shall be of CI with flanged ends. PN 16 pressure rating, EPDM seal. 150 mm dia

4

-

-

... More
Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required. 150 mm dia

4

-

-

... More
Supply and fix flexible connections with control rods for pumps, cooling tower & condenser. " 150 mm NB

14

-

-

... More
Supply, installation, testing & commissioning of Balancing Valve, with built in measuring facility with C.I Body, 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections; Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/- 150 mm NB

6

-

-

... More
Supply, installation, testing and commissioning of 4" Dial type thermometers with Stem with Copperplated steel, aluminium, or brass for thermo well installation and of length to suit installation, Stainless Steel U-Siphon as per specification

14

-

-

... More
Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection: Brass, NPS 12mm dia bottom-outlet type, Dial: Satin-faced, nonreflective braluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification.

14

-

-

... More
Supply, installation, testing & commissioning of differential pressure switch as per the specifications and as required.

3

-

-

... More
Supply, installation, testing & commissioning of the following motorized cut off valves as per the specifications and as required. Cl Body, Nylon coated DI disc, EPDM seal, minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required. 150 mm dia

6

-

-

... More
Ducting, Grills, Diffusers and Insulation

-

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 - 0.63 mm thick sheet

3300

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 - 0.80 mm thick sheet

1500

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 - 1.00 mm thick sheet

350

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006 - 1.25 mm thick sheet

10

-

-

... More
Supply, fabricate, handle, erect, balancing and commissioning of below thickness factory fabricated Aluminium ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces, slip on flanges, rubber gaskets, elbows, hangers, supports etc. etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as required. and as per specification. Thickness 0.80 mm Al. Sheet ducting

1150

-

-

... More
Supply, fabricate, handle, erect, balancing and commissioning of below thickness factory fabricated Aluminium ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces, slip on flanges, rubber gaskets, elbows, hangers, supports etc. etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as required. and as per specification. Thickness 1.00 mm Al. Sheet ducting

100

-

-

... More
Supply, fabricate, handle, erect, balancing and commissioning of below thickness factory fabricated Aluminium ducting as per drawing, complete with all fittings such as tee bends, special off-chutes, turning vanes, splitter dampers, ins.doors, transformation pieces, slip on flanges, rubber gaskets, elbows, hangers, supports etc. etc. as reqd. as per IS 655 including suspension and supporting arrangement for plenums, ducts, complete as required. and as per specification. Thickness 1.25 mm Al. Sheet ducting

100

-

-

... More
"TOTAL HEPA FILTRATION AREA – 5.4 Sq.mt: Ultra Clean Ventilation arrangement of A/C inside the Lab comprising of SS supply plenum including the 1.5"" flanges on all sides., material SS 304, 0.8mm, 2B finish. HEPA filters 0.3microns, efficiency 99.97% EU13 Sizes of - 1200X900X150 - 4 Nos, 900 x 600 x 150mm- 2 Nos. The HEPA filters will be fixed to the plenum using M6 SS rode, 304 Q type SS bolts and nuts). SS perforated sheets Mat finish. " Hepa filters (550 cfm x 4 nos.+ 500 x 2 Nos.) - OT

9

-

-

... More
Supply installing, testing and commissioning of (Factory Fabricated) HEPA filters of efficiency 99.9% down to 0.3 microns in filter plenum of 18 Gauge with rubber Gaskets In SS suitable frame work with 70% perforated grille "TOTAL HEPA FILTRATION AREA – 5.4 Sq.mt: Ultra Clean Ventilation arrangement of A/C inside the Lab comprising of SS supply plenum including the 1.5"" flanges on all sides., material SS 304, 0.8mm, 2B finish. HEPA filters 0.3microns, efficiency 99.97% EU13 Sizes of - 1200X900X150 - 4 Nos, 900 x 600 x 150mm- 2 Nos. The HEPA filters will be fixed to the plenum using M6 SS rode, 304 Q type SS bolts and nuts). SS perforated sheets Mat finish. Hepa filters 400 cfm - Burn ICU

11

-

-

... More
Supply, install, testing and commissioning of strip heaters comprising thermostat, humidistat, safety thermostat, contactors. Minimum capacity of strip heaters shall be 3 kW. 3 KW - Burn ICU

7

-

-

... More
Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications

3

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 225X225

5

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 300X300

340

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 375X375

130

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 225X225

15

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 300X300

345

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 375X375

135

-

-

... More
Supply installing, testing and commissioning of perforated aluminium grille for return with VCD and 10 Micron Filter in OT

30

-

-

... More
Supply, Fabrication, installation and testing of following size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification. 300 mm dia

550

-

-

... More
Supply, Fabrication, installation and testing of following size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification. 350 mm dia

225

-

-

... More
Supply installing, testing and commissioning of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 300 X 300 X 350 H

5

-

-

... More
Supply installing, testing and commissioning of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 350 X 350 X 450 H

340

-

-

... More
Supply installing, testing and commissioning of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 450 X 450 X 450 H

130

-

-

... More
Supply installing, testing and commissioning of Factory made fresh air dampers with louvers and control lever, filter etc. as required. (As per drawing)

26

-

-

... More
Supply installing, testing and commissioning of Factory made fresh air dampers having 20 micron filter with louvers and control lever. (For OT as per drawing)

1

-

-

... More
"Supply, fixing, balance and commissioning of louver type smooth supply air duct dampers made of extruded aluminium linkage, lever, brass bushings complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges, fixing arrangement etc., as per specifications. Al Volume control duct damper "

20

-

-

... More
Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link & micro switch to shut of corresponding AHU (including control cable.)

15

-

-

... More
Thermal insulation: Supply & fixing of 8/9 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3

2700

-

-

... More
Acoustic insulation: Supply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation open cell with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140- 180kg/m3

850

-

-

... More
Non AC area duct insulation: Supply & fixing of 19 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45- 55kg/m3

2850

-

-

... More
Ventilation System

-

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen, Motor : IE 3 3400 cfm Exhaust Blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen, Motor : IE 3 2800 cfm Exhaust Blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen, Motor : IE 3 2500 cfm Exhaust Blower

2

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen, Motor : IE 3 2300 cfm Exhaust Blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen, Motor : IE 3 2000 cfm Exhaust Blower

4

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioningDirect driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 1400 cfm Exhaust Blower

16

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 1100 cfm Exhaust blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 1000 cfm Exhaust blower

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 900 cfm Exhaust blower

3

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 800 cfm Exhaust blower

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 750 cfm Exhaust blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 450 cfm Exhaust blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 400 cfm Exhaust blower

11

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 350 cfm Exhaust blower

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 250 cfm Exhaust blower

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 200 cfm Exhaust blower

6

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 150 cfm Exhaust blower

42

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 100 cfm Exhaust blower

10

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 80 cfm Exhaust blower

17

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

1300

-

-

... More
Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc. as per standards and specification. Size: 100mm dia.

900

-

-

... More
Supply and fixing the following aluminium grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers. Design to be approved. Supply / Return air grille / diffuser with VCD

10

-

-

... More
Supply and fixing the following aluminium grilles and diffusers as per specifications. Machine made, powder coated, 150 x 150 exuast Grilles

500

-

-

... More
Additional Works

-

-

-

... More
UNDER DECK INSULATION - Supply & fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45 - 55kg/m3

2850

-

-

... More
Roof (inside) insulation for exposed slabs / walls: Supply & fixing of 12 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3.

700

-

-

... More
PIPE CLEANING AND CHEMICAL WATER TREATMENT FOR CONDENSER WATER: Automatic type Chemical dosing system, for condenser water piping system as per specification and drawing. Total package of flushing, chemical pre-cleaning, passivation and continuous maintenance treatment with chemicals etc. with necessary permanently installed equipment's and its controls. This package includes initial analysing of make up water sample. Then programming methods and duration. Accordingly, supply, install, test commission and maintain for a specified period with dosing pumps , tanks, water meters corrosion coupon tanks, valves with required chemicals and its micro-processor based controller with program etc. as per specification. Maintaining the clean piping system without corrosion, scale or micro-biological activity for an optimum operational efficiency and handing over the entire system in a healthy condition at the end of the contract which is the suppliers responsibility.

1

-

-

... More
Electrical Works

-

-

-

... More
MAIN PUMP PANEL Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. The panel shall complete with incomer & outgoing, Bus Bar Chamber, Volt Meter, Ammeter, fully automatic Star / delta / DOL starters for pumps as per the approved drawing & technical specification, Contactors, Auxiliary contacts, Indicating Lamps, Fuses, Auto / Manual Selector Switches, Manual On / Off Buttons, all internal wiring etc. as per the approved drawing and technical specification. The price for control panel shall be inclusive of all control cabling for functioning as per the design requirement and Earthing of the panel, all as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions. The panel shall be BMS compactible and CPRI approved. Incomer - 320A, 36 kA, FP MCCB Isolator - 1 Set. 320A 433V, 36kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 100A, 25/36kA, TP+NL, Thermal Magnetic release MCCB- 1 No. 63A, 25kA, TP+NL, Thermal Magnetic release MCCB + Starter + Accessories - 4 Set. 32A, 25kA, TP+NL, Thermal Magnetic release MCCB Starter + Accessories - 7 Set. 100A, 25kA, TP+NL, Thermal Magnetic release MCCB - Spare 63A, 25kA, TP+NL, Thermal Magnetic release MCCB - Spare

1

-

-

... More
AHU PANEL - 1 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL , Thermal Magnetic release MCCB - 14 Nos.

1

-

-

... More
AHU PANEL - 2 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 32A, FP, MCCB Isolator - 1 No. 32A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 3 Nos.

1

-

-

... More
AHU PANEL - 3 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 8 Nos

1

-

-

... More
AHU PANEL - 4 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 160A, FP, MCCB Isolator - 1 No. 160A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 12 Nos. 10A, TP+NL, MPCB - 2 No.

1

-

-

... More
AHU PANEL - 5 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 100A, FP, MCCB Isolator - 1 No. 100A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage,current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh. RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 10 Nos.

1

-

-

... More
AHU PANEL - 6 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 160A, FP, MCCB Isolator - 1 No. 160A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 12 Nos.

1

-

-

... More
AHU PANEL - 7 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 13 Nos. 16A, 16kA, TP+NL, Thermal Magnetic release MCCB - 4 No.

1

-

-

... More
AHU PANEL - 8 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 32A, 16kA, TP+NL, Thermal Magnetic release MCCB - 2 Nos. 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 1 Nos

1

-

-

... More
AHU PANEL - 9 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated bMV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 32A, 16kA, TP+NL, Thermal Magnetic release MCCB - 2 Nos. 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 1 Nos.

1

-

-

... More
LT Ccable works

-

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 4CX6 Sq.mm Al Cable

100

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 4CX4 Sq.mm Al Cable

1500

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3.5CX25 Sq.mm Al Cable

20

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3CX16 Sq.mm Al Cable

100

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3CX6 Sq.mm Al Cable

80

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3CX4 Sq.mm Al Cable

150

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 3 core x 1.5 sq mm copper Armoured Control cable

100

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date." 2 core x 1.5 sqmm copper Armoured Control cable

100

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date." 6 core x1.5 sq mm copper Armoured Control cable

250

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

2400

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required including end termination using copper lugs as per the requirement.. 2C x 1.5 sq. mm

100

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required including end termination using copper lugs as per the requirement.. 3C x 1.5 sq. mm

100

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required including end termination using copper lugs as per the requirement.. 6C x 1.5 sq. mm

250

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4CX6 Sq.mm Al Cable

8

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4CX4 Sq.mm Al Cable

70

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

6

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3CX6 Sq.mm Al Cable

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3CX4 Sq.mm Al Cable

64

-

-

... More
"Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 3C X 1.5 sq. mm

6

-

-

... More
"Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 2C X 1.5 sq. mm

6

-

-

... More
"Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 6C X 1.5 sq. mm

14

-

-

... More
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant. Copper wire No.10 SWG

1500

-

-

... More
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant. Copper wire No.8 SWG

100

-

-

... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

100

-

-

... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm copper strip

60

-

-

... More
Supplying and fixing of Lockable off push button near pumps & CT

15

-

-

... More
SITC of Control box & DIGITAL DISPLAY PANEL inside the Operation theater with indication lamp, ON/OFF of AHU control, thermostat control of OT, cooling & heating mode, humidity control etc. Digital display of RH/TEMPERATURE, pressure (including pressure sensor & necessary control), wiring from AHU to unit etc. as per dwg / picture attached"

9

-

-

... More
Building Management System

-

-

-

... More
Central core Computer - PC (Intel i7 Processor), 8 GB RAM, 2 GB Graphics card, DVD Writer, 22" LED monitor, 1 TB HDD, Microsoft mouse, Keyboards, 2 serial, 1 parallel port/KB, Windows 8 operating system, antivirus software

1

-

-

... More
A4 Colour Laser printer

1

-

-

... More
"System Controller to interface field level controllers to IBMS Workstation Supply, Installation, Testing and Commissioning of Building Management System Graphic User Interface software with 3 user client license, user groups, user profiles and scopes, alarm handling, scheduling, trending, reporting engine, database system, system activity log, historical data management, real time zoom enabled vector graphics, system backup and restore, HTML based documentation and help, SMS/Email facility complete in all respects as per tender specification. Graphical Software complete to cater to hardware points as specified in the Data Point Summary as well as Third Party Software Integrated Systems. Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer)"

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Chiller System - (50 points/chiller)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Secondary Pumps System (10 Points/Pump)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Variable Frequency Drives for AHU's (10 Points per VFD)

1

-

-

... More
Controls for Chiller System: Networkable DDC Controllers as per Data Point Summary (1- 5) with enclosure with all necessary wiring and accessories

1

-

-

... More
Controls for Chiller System: Immersion Type Temperature Sensor

4

-

-

... More
Controls for Chiller System: Outside Air Temperature & RH Sensor

1

-

-

... More
Controls for Chiller System: Level Switch for expansion tank ( 2 point) (depth of tank - 1 mtr.)

1

-

-

... More
Controls for Chiller System: Differential Pressure Switch

8

-

-

... More
Controls for Chiller System: Level Switch for cooling tower

3

-

-

... More
Controls for Chiller System: Differential Pressure Sensor

1

-

-

... More
Control for Air Handling Units - : Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC

9

-

-

... More
Control for Air Handling Units Supply, Installation, testing & commissioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC "

18

-

-

... More
Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 3 AHU / DDC

1

-

-

... More
Air Handling Units - 12 Nos.: Supply, Installation, testing & commissioning of Differential Pressure Switch across filter

12

-

-

... More
Air Handling Units - 12 Nos.: Supply, Installation, testing & commsssioning of Return air Temperature Sensor

12

-

-

... More
Air Handling Units with Heater - 3 Nos: Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter

3

-

-

... More
Air Handling Units with Heater - 3 Nos: Supply, Installation, testing & commsssioning of Return air Temperature Sensor

3

-

-

... More
Air Handling Units with Heater - 3 Nos.: Supply, Installation, testing & commsssioning of RH Sensor Room type

3

-

-

... More
Air Handling Units with Fine filter- 6 Nos. Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter- Pre filter, fine filter as required

12

-

-

... More
Air Handling Units with Fine filter- 6 Nos.: Supply, Installation, testing & commsssioning of Return air Temperature Sensor

6

-

-

... More
Air Handling Units with Fine filter, heater - 5 Nos.: Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter- Pre filter, fine filter as required

10

-

-

... More
Air Handling Units with Fine filter, heater - 5 Nos.: Supply, Installation, testing & commsssioning of Return air Temperature Sensor

5

-

-

... More
Air Handling Units with Fine filter, heater - 5 Nos.: Supply, Installation, testing & commsssioning of RH Sensor Room type

5

-

-

... More
Air Handling Units for OT - 9 Nos: Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter- Pre filter, fine filter and Hepa filter as required

27

-

-

... More
Air Handling Units for OT - 9 Nos: Supply, Installation, testing & commsssioning of Return air Temperature Sensor

9

-

-

... More
Air Handling Units for OT - 9 Nos: Supply, Installation, testing & commsssioning of RH Sensor Room type

9

-

-

... More
Air Handling Units for OT - 9 Nos.: Supply, Installation, testing & commissioning of Air Differential Pressure sensor

9

-

-

... More
AHU WITH HEAT RECOVERY WHEEL - 1 No: Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter as required

1

-

-

... More
AHU WITH HEAT RECOVERY WHEEL - 1 No: Supply, Installation, testing & commissioning of Return air Temperature Sensor

1

-

-

... More
AHU WITH HEAT RECOVERY WHEEL - 1 No: Supply, Installation, testing & commsssioning of RH Sensor Room type

1

-

-

... More
Signal Cabling - 2 Core 1.0 sq.mm. shielded FRLS armoured cable

2500

-

-

... More
Signal Cabling - 4 Core 1.0 sq.mm. shielded FRLS armoured cable

4200

-

-

... More
Signal Cabling - 8 Core 1.0 sq.mm. shielded FRLS armoured cable

1250

-

-

... More
Communication Cabling - 2 Core 1.5 sq.mm. shielded FRLS armoured cable or CAT5E armoured cable

1500

-

-

... More
SITC of Power Cable - 3 C X 2.5 SQMM -ATC Armoured Cable

600

-

-

... More
SITC of Cable tray 150 x 150 mm - 1.6mm

150

-

-

... More
Supplying and installing following size of pre galvenised iron floor race way including cover, GI bolts & nuts, etc. as required

150

-

-

... More
Medical Gas Pipeline System

-

-

-

... More
SITC of Oxygen Manifold - 2 banks x 14 cylinders

1

-

-

... More
SITC of Fully Automatic Oxygen Control Panel with minimum flow rate of 2000 LPM

1

-

-

... More
SITC of Emergency Oxygen Manifold - 2 banks x 6 cylinders

1

-

-

... More
SITC of Oxygen Flowmeters with humidifier bottle

344

-

-

... More
SITC of Nitrous Oxide Manifold - 2 banks x 1 cylinders

1

-

-

... More
SITC of Fully automatic Gas Control Panel for Nitrous Oxide with a minimum flow rate of 500 LPM

1

-

-

... More
SITC of Emergency Nitrous Oxide Manifold - 1 bank x 1 cylinders

1

-

-

... More
SITC of Carbon Dioxide Manifold - 2 banks x 1 cylinders

1

-

-

... More
SITC of Fully automatic Gas Control Panel for Carbon Di Oxide with minimum flow rate of 300 LPM

1

-

-

... More
SITC of Emergency Carbon Dioxide Manifold - 1 bank x 1cylinders

1

-

-

... More
SITC of Duplex Compressed air plant system each compressor having minimum free air delivery of 2000 LPM with complete accessories as mentioned in technical specifications.(Imported)

1

-

-

... More
SITC of Duplex vacuum plant system each pump having minimum free air aspirated of 2500 LPM at 450 mmHg with complete accessories as mentioned in technical specifications. (Imported)

1

-

-

... More
Ward Vacuum Units

334

-

-

... More
Theatre Vacuum Units

10

-

-

... More
SITC of ICU Terminal Units - Imported - O2

206

-

-

... More
SITC of ICU Terminal Units - Imported - Air

103

-

-

... More
SITC of ICU Terminal Units - Imported - VAC

205

-

-

... More
SITC of Ward Terminal Units - Indigenous - O2

231

-

-

... More
SITC of Ward Terminal Units - Indigenous - N2O

2

-

-

... More
SITC of Ward Terminal Units - Indigenous - Air

2

-

-

... More
SITC of Ward Terminal Units - Indigenous - Air 7 bar

2

-

-

... More
SITC of Ward Terminal Units - Indigenous - Vac

234

-

-

... More
SITC of Matching Probe - O2

437

-

-

... More
SITC of Matching Probe - N2O

2

-

-

... More
SITC of Matching Probe - Air

105

-

-

... More
SITC of Matching Probe - Air 7 ba

2

-

-

... More
SITC of Matching Probe - VAC

439

-

-

... More
SITC of Master Plant Alarm Panel (post source), BMS compatible,

1

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 6 Services

10

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 4 Services

15

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 2 Services

19

-

-

... More
SITC of Copper pipe - per mtr. - 12mm

2640

-

-

... More
SITC of Copper pipe - per mtr. - 15mm

2964

-

-

... More
SITC of Copper pipe - per mtr. - 22mm

3741

-

-

... More
SITC of Copper pipe - per mtr. - 28mm

1200

-

-

... More
SITC of Copper pipe - per mtr. - 35mm

224

-

-

... More
SITC of Copper pipe - per mtr. - 42mm

41

-

-

... More
SITC of Copper pipe - per mtr. - 54mm

151

-

-

... More
SITC of Copper pipe - per mtr. - 76mm

75

-

-

... More
SITC of Ball Valves - 15mm

15

-

-

... More
SITC of Ball Valves - 22mm

15

-

-

... More
SITC of Ball Valves - 28mm

13

-

-

... More
SITC of Ball Valves - 35mm

9

-

-

... More
SITC of Ball Valves - 42mm

3

-

-

... More
SITC of Ball Valves - 54mm

4

-

-

... More
SITC of Ball Valves - 76mm

1

-

-

... More
SITC of Bed Head Units - 1000 mm for Wards

24

-

-

... More
SITC of Bed Head Units - 1500 mm for ICU Category.

59

-

-

... More
SITC of Bed Head Panel - Running Meter

460

-

-

... More
SITC of Rigid Pendent

44

-

-

... More
Vertical Transport System 26 Passenger cum Bed Lifts

-

-

-

... More
LIFT-1,2,4,5 Supply installation testing and commissioning of 26 Passenger cum Bed Lift – Gearless with Machine Room, Capacity / Weight 26 Pass (1768 Kg), Speed 1.5 MPS, with ACVVVF microprocessor based control system,Travel 38.0 Meter approx.,Stops /openings 10 Stops / 10 Openings suitable for Shaft Size 2500 (W) x 3200 mm (D), with Simplex operation, Machine Room Location above the Hostway, CAR with 2mm Thick PVC Vinyl Flooring,Car Enclosure, Stainless Steel Hairline finish SS-304 enclosure with mirror on rear side panel. SS mirror finish handrails full length on one side as per car size. And of dimensions 1600 mm (W) X 2400 mm (D) X 2350mm (H) Car doors. 1200 mm (W) x 2100 mm (H) 2 panel automatic Telescopic / Centre opening doors with AC VVVF operation. SS-304 Decorative Stainless steel Hairline finish with Multi-beam infra-red/ultrasonic door detector. The lift shall be with recessed LED lights (warm white CCT 4000K) to give 150 lux lighting level; Battery-operated emergency light; Two no’s Blower fans with concealed vents. The ventilation and light shall be automatically cut off when the elevator is not in use; complete as per Technical Specifications.including all necessary safety features and in accordance with the particulars of lift service requirement.

4

-

-

... More
LIFT-7 Supply installation testing and commissioning of 26 Passenger cum Bed Lift – Gear less with Machine Room, Capacity / Weight 26 Pass (1768 Kg),Speed 1.5 MPS, with ACVVVF microprocessor based control system,Travel 34.0 Meter approx.,Stops /openings 09 Stops / 09 Openings suitable for Shaft Size 2500 (W) x 3000 mm (D), with Simplex operation, Machine Room Location above the Hostway, CAR with 2mm Thick PVC Vinyl Flooring,Car Enclosure, Stainless Steel Hairline finish SS-304 enclosure with mirror on rear side panel. SS mirror finish handrails full length on one side as per car size. And of dimensions 1600 mm (W) X 2400 mm (D) X 2350mm (H) Car doors. 1200 mm (W) x 2100 mm (H) 2 panel automatic Telescopic / Centre opening doors with AC VVVF operation. SS-304 Decorative Stainless steel Hairline finish with Multi-beam infra-red/ultrasonic door detector. The lift shall be with recessed LED lights (warm white CCT 4000K) to give 150 lux lighting level; Battery-operated emergency light; Two no’s Blower fans with concealed vents. The ventilation and light shall be automatically cut off when the elevator is not in use; complete as per Technical Specifications.including all necessary safety features and in accordance with the particulars of lift service requirement.

1

-

-

... More
Goods Cum Bed Lift

-

-

-

... More
LIFT-3,6 Supply installation testing and commissioning of 2T Goods cum Bed Lift – Gear less with Machine Room, Capacity / Weight 2T, Speed 1.0 MPS, with ACVVVF microprocessor based control system,Travel 38.0 Meter approx.,Stops /openings 10 Stops / 10 Openings suitable for Shaft Size 2500 (W) x 3200 mm (D), with Simplex operation, Machine Room Location above the Hostway, CAR with 2mm Thick PVC Vinyl Flooring, Car Enclosure, Stainless Steel Hairline finish SS-304 enclosure with mirror on rear side panel. SS mirror finish handrails full length on one side as per car size. And of dimensions 1600 mm (W) X 2400 mm (D) X 2350mm (H) Car doors. 1200 mm (W) x 2100 mm (H) 2 panel automatic Telescopic / Centre opening doors with AC VVVF operation. SS-304 Decorative Stainless steel Hairline finish with Multi-beam infra-red/ultrasonic door detector. The lift shall be with recessed LED lights (warm white CCT 4000K) to give 150 lux lighting level; Battery-operated emergency light; Two no’s Blower fans with concealed vents. The ventilation and light shall be automatically cut off when the elevator is not in use; complete as per Technical Specifications.including all necessary safety features and in accordance with the particulars of lift service requirement.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.