INKEL Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

INKEL Limited - INKEL Tender

Works
Eprocure
Opening Date22 Feb 2021
Closing Date8 Apr 2021
Tender Amount₹ 1,52,54,65,736 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

1953

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

59.5

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

50

-

-

... More
Sub Head -Plain cement concrete works

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

202.97

-

-

... More
Sub Head - Reinforced cement concrete and Shuttering work

-

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design).All work upto plinth level

466.13

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design).All work above plinth level upto floor V level

1465.92

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 340 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design).All work upto plinth level

2513.22

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 340 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design).All work above plinth level upto floor V level

9304.36

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

4976.36

-

-

... More
4.6.1 : Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)

14.21

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

411.09

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

5078.67

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

28239.56

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

41989.68

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

12284.8

-

-

... More
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards

7503.44

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

1248.14

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

76.47

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

31960

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete at all levels Thermo - Mechanically Treated bars of grade Fe-500D or more

2260576.05

-

-

... More
Sub Head- Block Work

-

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor Vlevel with RCC band at sill level and lintel level with approved block laying polymermodified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

7337.21

-

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in Plinth level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).(Upto Ground Floor Level)

1566.23

-

-

... More
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

2614.43

-

-

... More
6.2.2 : Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand)

237.63

-

-

... More
6.3.2 : Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With Modular bricks

184.64

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

24

-

-

... More
Sub Head - Steel work and Fire Doors

-

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

27004.19

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

5246.37

-

-

... More
13.85.2 : Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With ready mixed red oxide zinc chromatic on steel / iron works having VOC content less than 250 grams/ litre

147.31

-

-

... More
10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

133.92

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

26

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shutters Exceeding 10.00 sqm and upto 16.80 sqm in the area

112.32

-

-

... More
10.8.2 : Extra for providing mechanical device chain and crank operation for operating rolling shutters Exceeding 16.80 sqm in area

21.6

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

11.52

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

9951.72

-

-

... More
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes

62213.82

-

-

... More
Sub Head - Flooring and Waterproofing

-

-

-

... More
16.75 : Providing and laying C.C pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge ( The panel shuttering work shall be paid for separately)

442.72

-

-

... More
13.52.2 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work

8854.4

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

34127.36

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

1579.43

-

-

... More
Providing and fixing I st quality ceramic glazed wall tiles of size 600x600 conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(Note - Basic Price of tile - Rs 380/sqm Any savings/reduction in basic price shall be accounted in the bill on pro rata basis)

36631.18

-

-

... More
Providing and laying Vitrified step tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement matching pigments etc. complete.

612.19

-

-

... More
Extra for using or fixing glazed/ Ceramic/ Vitrified wall tiles with cement based high polymer modified quick-set tile adhesive ( Water based) conforming to IS : 15477, in average 3 mm thickness.

36631.18

-

-

... More
8.12 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvillinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge.a. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

1696.06

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade.Area of slab over 0.50 sqm

121.45

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

3351.15

-

-

... More
8.13.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.

100

-

-

... More
Grading roof for water proofing treatment with 12mm thick plastering in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and mixing with water proofing material in proportion recommended by the manufacturers

4533.85

-

-

... More
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels /subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

4525.26

-

-

... More
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

1695.3

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

3342.61

-

-

... More
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate

628.18

-

-

... More
Sub Head - Expansion Joint

-

-

-

... More
Providing and fixing in position 25mm to 30 mm thick bitumen impregnated fibre board conforming to IS: 1838, including cost of primer, sealing compound in expansion joints between Beams, Slabs and Columns at all level

35.94

-

-

... More
Labour material and supervision charges for filling 25 mm baker road and PU sealant, providing synthetic expansion tape-Mapei band Tape 170 or equivalent on floor using Adesilex PG 2 of Mapei(in 1:3 ratio) or equivalent and filling PU sealant upto floor finish level and provide Aluminium 3.15 mm thick strips- 200 mm wide All complete as per manufacture specification.

184.1

-

-

... More
5.29.2.1 : Providing and fixing sheet covering over expansion joints with iron screws as per design.Aluminium fluted strips 3.15 mm thick150 mm wide

184.1

-

-

... More
Anchoring of reinforcement bars in already casted concrete by drilling the required diameter holes at the required depth and as per the design diameter and applying anchoring chemical of Hilti Re-500 or equivalent after cleaning the hole from all debriesand fixing the reinforcement bars in the chemical etc.complete.8mm dia bar, 12 mm dia hole dia and 8cm depth

768

-

-

... More
Anchoring of reinforcement bars in already casted concrete by drilling the required diameter holes at the required depth and as per the design diameter and applying anchoring chemical of Hilti Re-500 or equivalent after cleaning the hole from all debriesand fixing the reinforcement bars in the chemical etc.complete.10mm dia bar, 14 mm dia hole dia and 10cm depth

2832

-

-

... More
Anchoring of reinforcement bars in already casted concrete by drilling the required diameter holes at the required depth and as per the design diameter and applying anchoring chemical of Hilti Re-500 or equivalent after cleaning the hole from all debriesand fixing the reinforcement bars in the chemical etc.complete.12mm dia bar, 16 mm dia hole dia and 12cm depth

837

-

-

... More
Anchoring of reinforcement bars in already casted concrete by drilling the required diameter holes at the required depth and as per the design diameter and applying anchoring chemical of Hilti Re-500 or equivalent after cleaning the hole from all debriesand fixing the reinforcement bars in the chemical etc.complete.16mm dia bar, 20 mm dia hole dia and 16cm depth

167

-

-

... More
Sub Head - Finishes

-

-

-

... More
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).

36832.95

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

177.7

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - At all levels 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size)

332.95

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

120222.82

-

-

... More
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

6796.49

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

5966

-

-

... More
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

3981.53

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

35833.49

-

-

... More
Sub Head - External Works

-

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

25

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

25.2

-

-

... More
15.6 : Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B work.

80000

-

-

... More
24.2 : Providing and fixing double scaffolding system (Cup lock type ) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube chakkus, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and / or pointing and / or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-Charge. Note: - ( 1) The evaluational area of the scaffolding shall be measured for payment purpose, (2) The payment will be made once only for execution of all items of such works.

1686

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

9.9

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

4500

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

100

-

-

... More
2.10.1.3 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

450

-

-

... More
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m.Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

150

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

500

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

100

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

979.14

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

150

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

135

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

4600

-

-

... More
19.35.1 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.

250

-

-

... More
19.35.2 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.600 mm dia RCC pipes.

200

-

-

... More
16.1 : Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

9500

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

3072.34

-

-

... More
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design& pattern.

3251.67

-

-

... More
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

12110

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

389.52

-

-

... More
16.90 : Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

460

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

634.65

-

-

... More
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

246.31

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size of Grade C having average compressive strength 4N/mm^2 and individual compressive strength 3.2N/mm^2 as specified in IS 2185 part I of 2005 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

303.93

-

-

... More
Dry stone pitching for rainwater collection pond- Dry stone pitching 300mm thick laid in courses and required profile with hammer dressed stones having no side less than 150mm, with minimum depth of 200mm including preparing the bedding surface etc. all complete for all heights including providing concrete bands, pointing with CM 1:6 etc. as directed by the Engineer in charge / drawing.

780

-

-

... More
Dry RR Masonry for rainwater collection pond - Dry random rubble masonry using approved quality rubble, at all heights with necessary binding stones etc. in line and levels, pointing with CM 1:6 as instructed by the Engineer in charge. The rate shall include cost of all materials, labour, transportation, scaffolding charge etc. complete for all heights as per the drawing.

142.2

-

-

... More
Sub Head - Roofing works

-

-

-

... More
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2

728.52

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

3110.69

-

-

... More
JOINERY AND FINISHES - Sub Head Joinery & Structural Glazing

-

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sectionsas per the architectural drawings and approved shop drawings , the aluminiumquality as per grade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colour and shadeas approved by the Engineer-in-Charge. ( The item includes cost of material suchas cleats, sleeves, screws etc. necessary for fabrication of extruded aluminiumframe work. Nothing extra shall be paid on this account).

19626.48

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi(grid) unitized system of structural glazing (with open joints) for linear as well ascurvilinear portions of the building for all heights and all levels, including:a) Structural analysis & design and preparation of shop drawings for the specifieddesign loads conforming to IS 875 part III (the system must passed the proof testat 1.5 times design wind pressure without any failure), including functional designof the aluminum sections for fixing glazing panels of various thicknesses, aluminiumcleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clampsetc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmokeseals, microwave cured EPDM gaskets for water tightness, pressureequalisation & drainage and protection against fire hazard including:b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3Dimentional movement for achieving perfect verticality and fixing structural glazingsystem rigidly to the RCC/ masonry/structural steel framework of building structureusing stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetalliccontacts with nuts and washers etc. of stainless steel grade 316, of the requiredcapacity and in required numbers.c) Providing and filling, two part pump filled, structural silicone sealant and onepart weather silicone sealant compatible with the structural silicone sealant ofrequired bite size in a clean and controlled factory / work shop environment ,including double sided spacer tape, setting blocks and backer rod, all of approvedgrade, brand and manufacture, as per the approved sealant design, within and allaround the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thickand of sizes, shapes and profiles, as required as per the site conditions, to seal thegap between the building structure and all its interfaces with curtain glazing tomake it watertight.e) Making provision for drainage of moisture/ water that enters the curtain glazingsystem to make it watertight, by incorporating principles of pressure equalization,providing suitable gutter profiles at bottom (if required), making necessary holesof required sizes and of required numbers etc. complete. This item includes costof all inputs of designing, labour for fabricating and installation of aluminium grid,installation of glazed units, T&P, scaffolding and other incidental charges includingwastages etc., enabling temporary structures and services, cranes or cradles etc.as described above and as specified. The item includes the cost of getting all thestructural and functional design including shop drawings checked by a structuraldesigner, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of theindividual components for testing in an approved laboratory, field tests on theassembled working structural glazing as specified, cleaning and protection till thehanding over of the building for occupation. In the end, the Contractor shall providea water tight structural glazing having all the performance characteristics etc. allcomplete as required, as per the Architectural drawings, as per item description,as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extrudedaluminium section capping for fixing in the grooves of the curtain glazing andvermin proof stainless steel wire mesh shall be paid for separately under relevantitems under this sub-head. However, for the purpose of payment, only the actualarea of structural glazing (including width of grooves ) on the external face shallbe measured in sqm. up to two decimal places.Note:-2. The following performance test are to be conducted on structural glazingsystem if area of structural glazing exceeds 2500 Sqm from the certified laboratoriesaccreditated by NABL(National Accreditation Board for Testing and CalibrationLaboratories), Department of Science & Technologies, India. Cost of testing ispayable separately. The NIT approving authority will decide the necessity of testingon the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing systemTests to be conducted in the NBL Certified laboratories1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to+300pa) as perASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testingmethod for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testingmethod for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testingmethod for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method forQualitative test” Tests to be conducted on site6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)upto 2000ml”

2768.57

-

-

... More
25.3 : Providing, assembling and supplying vision glass panels (IGUs) comprising ofhermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel unitsof size and shape as required and specified, comprising of an outer heatstrengthened float glass 6mm thick, of approved colour and shade with reflectivesoft coating on surface # 2 of approved colour and shade, an inner Heat strengthnedclear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primaryseal and secondary seal (structural silicone sealant) etc. all complete for the requiredperformances, as per the Architectural drawings, as per the approved shopdrawings, as specified and as directed by the Engineer-in-Charge. The IGUs shallbe assembled in the factory/ workshop of the glass processor. (Payment for fixingof IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment,only the actual area of glass on face # 1 of the glass panels (excluding the areas ofthe grooves and weather silicone sealant) provided and fixed in position, shall bemeasured in sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating onface # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved makehaving properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflectioninternal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performanceglass shall be decided by technical sanctioning authority as per the site requirement

1507.53

-

-

... More
Supply &Installation aluminum louvers of Hindalco section 85191 or equivalent. The Fins should be fixed at 200mm module based on the requirement to the suitable Installation frame of aluminium(Powder coated aluminium minimum thickness of powder coating 50 micron) extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings .The maximum length of the fin shall be determined based on the wind load calculation and deflection.

1556.33

-

-

... More
Providing and supplying Single glazing comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with transmission 31% min,external reflection 14% and internal reflection 17% so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass shall be measured in sqm. (Payment for fixing of Glass panels in the curtain glazing is included in cost of relevent item*).

1176.8

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

14286.3

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

24748.64

-

-

... More
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

1234.28

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

2007

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

861.39

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

575

-

-

... More
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) locking arrangement for sliding windows including necessary screws and fittings of approved make as directed by Engineer-in-charge.

2196

-

-

... More
Providing and fixing roller for shutters of sliding aluminium windows with necessary screws etc.complete.As approved by Engineer-in-charge

8784

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

830

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

2313

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

914.31

-

-

... More
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

246

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

110

-

-

... More
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm

1047

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm

1047

-

-

... More
21.18 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

264.66

-

-

... More
Providing and fixing Stainless steel D type glass door handle with SSS polished finish of 25mmx450mm size.

125

-

-

... More
Providing and fixing Stainless Steel Corner Patch Lock with Strike Plate of SSS finish for toughened glass door including all necessary fittings Or equivalent.

125

-

-

... More
Automatic 6.0 mtr std-Bi Parting Sliding door (TAM-PS-01) with accessories including : Automatic Track with operational kit Sensor-2, Glass Clamp-2(1 .5Mtr each),Floor guides,seals,Safety Beam

2

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.2400mmX2400mm

1

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.2000mmX2400mm

12

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1500mmX2400mm

34

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1200mmX2400mm

6

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1000mmX2100mm

3

-

-

... More
Double Leaf SS 304 Finish Swing Door: Product Description : Size 2000mm (W) 2400 mm (H). with clear opening of 1880 mm x 2340 mm. 44 mm (THK) PUF infil door leaf Component Polyurethane Rigid CFC Free, Blowing Agent: Water. Dimensional stability at +100 deg C &25degC (2%max) as per DIN53431. Density 45Kg/M3 with max deviation of 2kg/m3 as per DIN53420. Condensation resistance at 38degC and 88RH Max variation 2% in weight and volume . 0.6 mm SS 304 finish door leaf,double glazed vision panel with 4 mm clear glass (300 mm X 300 mm), Anodized door profile Aluminium Wall frame 80mm x 60mm Al 6063 anodized, 2.5 mm thick with GI reinforcment with conealed dead lock for passive leaf with Locking cylinder,closure, Ball Bearing Hinge 4 nos per leaf, D handle (back to back)- No organic material no decay.

3

-

-

... More
Double Leaf SS 304 Finish Swing Door: Product Description : Size 1500mm (W) 2400 mm (H). with clear opening of 1380 mm x 2340 mm. Passive leaf size 300 mm 44 mm (THK) PUF infil door leaf Component Polyurethane Rigid CFC Free,Blowing Agent: Water. Dimensional stability at +100degC &25degC (2%max) as per DIN53431. Density 45Kg/M3 with max deviation of 2kg/m3 as per DIN53420.Condensation resistance at 38degC and 88RH Max variation 2% in weight and volume. 0.6 mm SS 304 finish door leaf, double glazed vision panel with 4 mm clear glass (300 mm X 300 mm), Anodized door profile Aluminium Wall frame 80mm x 60mm Al 6063 anodized, 2.5 mm thick with GI reinforcment with conealed dead lock for passive leaf with Locking cylinder, closure, Ball Bearing Hinge 4 nos per leaf, D handle (back to back)- No organic material no decay.

3

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.2000mmx2400mm

10

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.1500mmX2400mm

9

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 1200mmX2400mm

1

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 1200mmX2100mm

13

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 1000mmX2100mm

6

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 900mmX2100mm

9

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 800mmX2100mm

1

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 2000mmX2200mm

4

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

533

-

-

... More
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

492

-

-

... More
Providing and fixing in position frameless fixed glazing using 10mm toughened glass fitted with patch fittings of approved brand or manufacture as detailed in the draiwng of specified size including supplying and fixng necessary holdfasts, screws for fixing cleats, toughened glass with all labour and materials complete as per drawings and as directed.

786.24

-

-

... More
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

1940

-

-

... More
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm

110

-

-

... More
9.106.2 : Providing and fixing PTMT handles with necessary screws etc. complete.150x34x24 mm weighing not less than 26 gms

888

-

-

... More
9.108.2 : Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms

888

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

779

-

-

... More
Providing and fixing 1 mm thick M.S. sheet door with shutter frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings with outer frame of size 50x50x6 mm complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

628.88

-

-

... More
10.25.1 :Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

1934.8

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

1.51

-

-

... More
9.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shutters

113.76

-

-

... More
9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

85.32

-

-

... More
50.9.15.2 : Supplying and fixing 300 mm Aluminium aldrop

35

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

35

-

-

... More
13.48.2 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture

295.78

-

-

... More
Frosted film - Supply and installation of 3M make frosted film pattern throughout all the internal glass panels wherever required of approx. 1.5 m height as per the approved pattern.

971.5

-

-

... More
9.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded

613.8

-

-

... More
9.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperately

316.44

-

-

... More
9.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).

3.15

-

-

... More
9.139 : Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

35

-

-

... More
9.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm

72

-

-

... More
6.40 : Providing and laying Gypsum panel partitions 100 mm thick with water proof Gypsum panels of size 666x500x100 mm, made of calcite phosphor Gypsum fixed with tongue and groove, jointed with bonding plaster as per manufacturers specifications in superstructure above plinth level up to floor V level. Gypsum blocks will have a minimum compressive strength of 9.3 kg/cm2

1036.22

-

-

... More
Sub Head:False Ceiling Works

-

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending

11459.23

-

-

... More
12.52.2 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm drop; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.

14929.47

-

-

... More
ALUMINUM METAL false ceiling work: Providing & Fixing False ceiling of Armstrong ALUMINUM Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles in 0.7 mm thick Aluminum pre coated to Global white color to be laid on Armstrong grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm & 600 mm Cross Tees. The tile shall maintain uniform Thickness of 0.7mm across all areas. The tile shall have paint thickness of 25 microns to enable better scratch resistance and shall have the ability to combine the main light with extra illumination providing 77% light reflectance & enables to achieve light uniformity. The tile shall have g Ceiling Attenuation Class of 44db. To comprise main runner spaced at 1200mm centers securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centers.

1444.64

-

-

... More
12.52.3 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit.

3920.12

-

-

... More
12.52.4 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plaster board having glass fibre conforming to IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of 0.79, with 50 mm resin bonded glass wool backing.

540.63

-

-

... More
12.58.1 : Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long space between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening of services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 Kg/ sq. cm, bending strength 100 Kg/sq. cm, of size 595x595 mm, having perforation of dia, 10 mm with minimum perforated area 18% with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 Kg/cum backing.

2219.56

-

-

... More
Sub Head:Roofing

-

-

-

... More
Poly carbonate sheet roofing -Supply and installation of 2mm thick Poly-carbonate sheet roofing of approved make, embossed clear with UV protection coating/treatment and weight not less than 2400 gms/ sqm. It shall be fire retardant and confirming to IS 14443. the rate shall include aluminium leak proofing and fixing management system with EPDM rubber gaskets, silicone sealant etc. complete as required and as per the direction of engineer in chargeexcluding purlins, rafters and trusses and including cutting to size and shape wherever required.

536.62

-

-

... More
Providing and supplying Single glazing comprising of 6 mm ET 125 Heat Strengthened+ 1.52 PVB + 6 mm Clear Toughened monolithic float glass of approved colour and shade with transmission 28% min,external reflection 28% and internal reflection 9%., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass shall be measured in sqm. -For central cut out skylight portion of roof.)The joints of glass shall be water proofed with clear silicant filling of approved brand. Cost of steel work shall be paid separately.

203.15

-

-

... More
10.16.2 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes

14795.4

-

-

... More
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2

133.51

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

355.09

-

-

... More
Sub Head:Finishes

-

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

51043.96

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

110553.02

-

-

... More
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

99082.81

-

-

... More
PUBLIC HEALTH ENGINEERING (PHE) SYSTEM - Subhead : SANITARY FIXTURES

-

-

-

... More
Providing and fixing White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF Dual Cistern, overall size 765 x 370 x 650mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion/ rawl sleeves, gasket etc. complete, and fixing to wall, as per manufacturer's instruction and to the approval of Engineer-in-charge.

365

-

-

... More
Providing and fixing sanitary fixtures for handicapped toilet including one number Extended wall mount closet with soft close seat cover and cistern one wash basin, one pair mounting brackets,one number elbow operated pillar cock and all other related fittings like waste coupling one number hinged rail 76 cm & 4 nos. of grab rails 60cm etc designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge.

13

-

-

... More
Supplying, installing, testing & commissioning at site in position white / colour vitreous china wash basin (480x365x205mm) with C.I./MS brackets painted white, C.P brass waste coupling of standard pattern, 32mm dia C.P, basin Pillarcock with aerator, including cutting & making good the walls wherever required complete. Wash basin below counter type with aerator PillarCock.

235

-

-

... More
17.7.4 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brasspillar taps

156

-

-

... More
17.7.9 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon Type wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps with elbow operated levers ISI marked

86

-

-

... More
17.80 : Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx.size 610x390x370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer - in-charge.

105

-

-

... More
8.10.2 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade

18

-

-

... More
Hot & cold CP aerator wall mixer unit - Providing, Fixing, testing and commissioning Of Hot & cold CP wall mixer unit with long bend pipe for overhead shower with all accessories.

71

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

150

-

-

... More
17.72 : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms

140

-

-

... More
50.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

378

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

120

-

-

... More
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore

868

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

340

-

-

... More
17.10.1.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm

10

-

-

... More
17.11.2 : Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm

110

-

-

... More
Providing, fixing, testing, and commissioning at site Kitchen Sink Cock with aerator, Wall Mounted Type 15mm. nominal bore, overall dimensions: 208x237mm, including all necessary accessories, all as per manufacturer's instruction and to the approval of the Engineer-in-charge.

20

-

-

... More
Providing, fixing, testing, and commissioning at site Single Lever Surgical Purpose Elbow Action Sink Mixer (Wall Mounted)with aerator Extended Operating Lever, Connecting legs & wall flanges, 15mm. nominal bore, including all necessary accessories, all as per manufacturer's instruction and to the approval of the Engineer-in-charge.

110

-

-

... More
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore

49

-

-

... More
18.22.1 : Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter

120

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

1246

-

-

... More
17.34.1 : Providing and fixing toilet paper holder:C.P. brass

4

-

-

... More
Supplying, installing, testing & commissioning at site in position Grab Bar up to 600mm complete.

10

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

317

-

-

... More
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

205

-

-

... More
C. P. Robe Hook,60mm. Dia. x 45mm. High.

410

-

-

... More
17.28.1.2 : Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC. waste fittings complete.Semi rigid pipe40 mm dia

477

-

-

... More
Providing,fixing testing and commissioning 1½"x 40x300 Plastic P Trap (P Trap) for Sink. Adjusting pipe 120mm, drain elbow 220mm.

120

-

-

... More
Subhead : INTERNAL DRAINAGE

-

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal). 160mm OD

125

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal). 110mm OD

3450

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal). 75mm OD

3000

-

-

... More
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall

2023

-

-

... More
50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall

300

-

-

... More
50.18.9.14.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall

300

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

477

-

-

... More
50.18.8.5.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2

230

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type A (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Vent pipes -Internal). 75mm OD

100

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of 4kg/cm2 (IS:4985)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Vent pipes -Internal). 63mm OD

275

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 160mm OD

300

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 110mm OD

1325

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 75mm OD

30

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 160mm OD

450

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 110mm OD

550

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 75mm OD

710

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe of 4kg/cm2 (IS:4985)) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 63 mm OD(4kg/cm2)

84

-

-

... More
Deep Seal uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position Deep Seal (7”) uPVC Fabricated Multi Floor Trap, with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, Anchor fasteners etc. complete in all respects - 50/75 mm dia inlet/outlet (In Ceiling)

850

-

-

... More
uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost o cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken)

90

-

-

... More
Supplying, installing, testing & commissioning at site in position 110mm dia deep seal PVC P Trap with boss tee and access cap including all necessary fittings and supports complete.

41

-

-

... More
C.P. cast brass or stainless steel Square Flat cut lock anti cockroach grating cover - Providing and Fixing Heavy Duty Stainless Steel Square Flat cut lock anti Cockroach Trap Stainless Steel A ISI 304 with 125x125 mm. Grating, for 110mm. Floor Traps.

940

-

-

... More
Heavyduty stainless steel cover for Concealed Floor Trap for Urinal - Providing and Fixing 125x125mm dia Heavyduty stainless steel cover for Concealed Floor Trap ISI 304 Cover, for Urinal.

41

-

-

... More
Heavyduty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable insert keys for opening, if required.

51

-

-

... More
Low noise level soil & waste system 160mm Dia - Providing, Fixing, testing Low noise level soil & waste system as per EN 12056, DIN 4109, as approved in proper line and level jointing With push fit rubber ring socket fittings complete with holder bats or dash fasteners fixed to walls or ceiling or run on floor or in trenches at require slopes and necessary special heavy Detachable Hot Dip Galvanized M.S. Brackets, Hangers, clamps and bricks / RCC pedestals as directed, including clamps, bracket, supports in MS making good walls etc. The rates for pipes shall be inclusive of all the specials, and fittings like elbow, rodding eye etc., The diameter of pipe shall be of the following nominal bore.(Pipes and fittings shall consist of polypropylene mineral reinforce with sound insulation density not less than 1.9gm/cm3). Astral Silencio shall have a B2 fire classification according to EN 4102 and shall be hot water resistant up to 95°C short term loading (90°C long term loading) with a chemical resistance of pH 2-12 and complete sound protection system according to DIN 4109. Galvanized clamps and brackets, legend boards shall be included in the price.

200

-

-

... More
Low noise level soil & waste system 110mm Dia - Providing, Fixing, testing Low noise level soil & waste system as per EN 12056, DIN 4109, as approved in proper line and level jointing With push fit rubber ring socket fittings complete with holder bats or dash fasteners fixed to walls or ceiling or run on floor or in trenches at require slopes and necessary special heavy Detachable Hot Dip Galvanized M.S. Brackets, Hangers, clamps and bricks / RCC pedestals as directed, including clamps, bracket, supports in MS making good walls etc. The rates for pipes shall be inclusive of all the specials, and fittings like elbow, rodding eye etc., The diameter of pipe shall be of the following nominal bore.(Pipes and fittings shall consist of polypropylene mineral reinforce with sound insulation density not less than 1.9gm/cm3). Astral Silencio shall have a B2 fire classification according to EN 4102 and shall be hot water resistant up to 95°C short term loading (90°C long term loading) with a chemical resistance of pH 2-12 and complete sound protection system according to DIN 4109. Galvanized clamps and brackets, legend boards shall be included in the price.

150

-

-

... More
Low noise level soil & waste system 75mm Dia - Providing, Fixing, testing Low noise level soil & waste system as per EN 12056, DIN 4109, as approved in proper line and level jointing With push fit rubber ring socket fittings complete with holder bats or dash fasteners fixed to walls or ceiling or run on floor or in trenches at require slopes and necessary special heavy Detachable Hot Dip Galvanized M.S. Brackets, Hangers, clamps and bricks / RCC pedestals as directed, including clamps, bracket, supports in MS making good walls etc. The rates for pipes shall be inclusive of all the specials, and fittings like elbow, rodding eye etc., The diameter of pipe shall be of the following nominal bore.(Pipes and fittings shall consist of polypropylene mineral reinforce with sound insulation density not less than 1.9gm/cm3). Astral Silencio shall have a B2 fire classification according to EN 4102 and shall be hot water resistant up to 95°C short term loading (90°C long term loading) with a chemical resistance of pH 2-12 and complete sound protection system according to DIN 4109. Galvanized clamps and brackets, legend boards shall be included in the price.

35

-

-

... More
Low noise level soil & waste system 50mm Dia - Providing, Fixing, testing Low noise level soil & waste system as per EN 12056, DIN 4109, as approved in proper line and level jointing With push fit rubber ring socket fittings complete with holder bats or dash fasteners fixed to walls or ceiling or run on floor or in trenches at require slopes and necessary special heavy Detachable Hot Dip Galvanized M.S. Brackets, Hangers, clamps and bricks / RCC pedestals as directed, including clamps, bracket, supports in MS making good walls etc. The rates for pipes shall be inclusive of all the specials, and fittings like elbow, rodding eye etc., The diameter of pipe shall be of the following nominal bore.(Pipes and fittings shall consist of polypropylene mineral reinforce with sound insulation density not less than 1.9gm/cm3). Astral Silencio shall have a B2 fire classification according to EN 4102 and shall be hot water resistant up to 95°C short term loading (90°C long term loading) with a chemical resistance of pH 2-12 and complete sound protection system according to DIN 4109. Galvanized clamps and brackets, legend boards shall be included in the price.

50

-

-

... More
Low noise level soil & waste system 110mm Dia - Providing, Fixing, testing Low noise level soil & waste system as per EN 12056, DIN 4109, as approved in proper line and level jointing With push fit rubber ring socket fittings complete including clamping with Position, including cutting and making good the walls and floors as required at site. The rates for pipes shall be inclusive of all the specials, and fittings like elbow, rodding eye etc., The diameter of pipe shall be of the following nominal bore.(Pipes and fittings shall consist of polypropylene mineral reinforce with sound insulation density not less than 1.9gm/cm3). Astral Silencio shall have a B2 fire classification according to EN 4102 and shall be hot water resistant up to 95°C short term loading (90°C long term loading) with a chemical resistance of pH 2-12 and complete sound protection system according to DIN 4109. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.

210

-

-

... More
Supplying, installing & testing at site in position Deep Seal Polypropylene floor trap (ht 7") - (sound level 13dB @4L/sec) supporting on GI slotted rails (1.6mmthick) full threaded rod, Anchor fasteners etc. with all necessary fittings of approved make.

15

-

-

... More
Supplying, installing & testing at site in position Polypropylene P Trap - (sound level 13dB @4L/sec)of size 110mm dia of approved make for Drainage, complete with all necessary fittings of approved make as per drawings to the satisfaction of the project manager.

20

-

-

... More
17.35.1.3 : Providing and fixing soil, waste and vent pipes:100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside &outside IS:15905

175

-

-

... More
17.38.1.3 : Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm diaHubless centrifugally cast (spun) iron epoxy coated inside & outside asper IS:15905

40

-

-

... More
17.39.1.3 : Providing and fixing plain bend of required degree.100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside &outside IS:15905

18

-

-

... More
17.42.1.3 : Providing and fixing double equal plain junction of required degree.100x100x100x100 mmHubless centrifugally cast (spun) iron pipes epoxy coated inside &outside IS:15905

6

-

-

... More
17.44.1.3 : Providing and fixing single equal plain junction of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outsideas per IS:15905

15

-

-

... More
17.49.1.3 : Providing and fixing double equal plain invert branch of required degree:100x100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as perIS:15905

2

-

-

... More
17.50.1.3 : Providing and fixing single equal plain invert branch of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as perIS:15905

8

-

-

... More
17.56.1.3 : Providing and fixing terminal guard:100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as perIS:15905

1

-

-

... More
17.60.1.3 : Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outletHubless centrifugally cast (spun) iron epoxy coated inside & outside as perIS:15905

18

-

-

... More
17.57A.1.1 : Providing and fixing shielded coupling for Hubless centrifugally cast iron pipeSS 304 grade coupling with EPDM rubber gasket

130

-

-

... More
12.44 : Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.

45

-

-

... More
Subhead : WATER SUPPLY

-

-

-

... More
18.8.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes

735

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

5850

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

300

-

-

... More
18.7.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15 mm nominal outer dia pipes

650

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

7750

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

2625

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

1500

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

830

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

285

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 20 mm nominal outer dia. Pipes.

500

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 25 mm nominal outer dia. Pipes.

300

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 32 mm nominal outer dia. Pipes.

400

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 40 mm nominal outer dia. Pipes.

300

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 50 mm nominal outer dia. Pipes.

625

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes.

690

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 80 mm nominal outer dia. Pipes.

500

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 100 mm nominal outer dia. Pipes.

130

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes.

200

-

-

... More
18.18.1 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:15 mm nominal bore

50

-

-

... More
18.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

1150

-

-

... More
18.18.3 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore

115

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

65

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

25

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

16

-

-

... More
18.19.2.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):32 mm nominal boreHorizontal

2

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

2

-

-

... More
Brass Automatic Air Release Valves - Providing, Fixing, testing and commissioning at site in positions Brass Automatic Air Release Valves, of approved quality and make on the top of the vertical water supply pipes as per specification and drawing - 3/4"(20mm) dia

20

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN 6) of approved make with PP float & nipple with brass threaded insert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 40mm dia (1 ½”)

1

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN6) of approved make with PP float & nipple with brass threaded insert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 50mm dia (2”)

1

-

-

... More
SS ball valve 15mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - ½” (15mm) dia

120

-

-

... More
SS ball valve 20mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - ¾” (20mm) dia

100

-

-

... More
SS ball valve 25mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - 1” (25mm) dia

10

-

-

... More
SS ball valve 32mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - 1¼”(32mm) dia

5

-

-

... More
SS ball valve 40mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - 1½”(40mm) dia

5

-

-

... More
SS ball valve 50mm dia - Providing, Fixing at site in position full way lever operated forged SS ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings. - 2”(50mm) dia

6

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect.50 mm dia

3

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect.65 mm dia

7

-

-

... More
HEAVY DUTY WITH PULSE OUTPUT -Water Meter conforming to ISO 4064 (1) Class B, Cold water meter with flanged ends, Body made of Epoxy Coated Cast Iron body with Metal Protective Lid, Magnetic coupled, Dry Dial with Straight Reading in KILO Litres, with completely removable and interchangeable internal mechanism. Highly Durable with Low Head Loss and sensitive to Low Flow Rate. Suitable for Horizontal Installation only & Have a ReAd Switch For pulse output. Output is compactable for SMART meters.Water meter 40mm

3

-

-

... More
CLASS-‘B’-HEAVY DUTY-WITH PULSE OUT PUTWater Meter conforming to ISO 4064(1) Standards. BRASS BODY (SCREW TYPE) with BRASS REGISTRATION BOX Inferential Super Dry Dial Straight Reading in KILO Litres, Horizontal flow, Magnetically Coupled Water Meters as per IS:779 ISI marked & Conforming to ISO:4064(I) Class B standards with IP 68 Protection Class & Have a Reed Switch For pulse output. Output is compactable for SMART meters..Water meter 50mm

1

-

-

... More
CLASS-‘B’-HEAVY DUTY-WITH PULSE OUT PUTWater Meter conforming to ISO 4064(1) Standards. BRASS BODY (SCREW TYPE) with BRASS REGISTRATION BOX Inferential Super Dry Dial Straight Reading in KILO Litres, Horizontal flow, Magnetically Coupled Water Meters as per IS:779 ISI marked & Conforming to ISO:4064(I) Class B standards with IP 68 Protection Class & Have a Reed Switch For pulse output. Output is compactable for SMART meters.Water meter 65mm

1

-

-

... More
CLASS-‘B’-HEAVY DUTY-WITH PULSE OUT PUTWater Meter conforming to ISO 4064(1) Standards. BRASS BODY (SCREW TYPE) with BRASS REGISTRATION BOX Inferential Super Dry Dial Straight Reading in KILO Litres, Horizontal flow, Magnetically Coupled Water Meters as per IS:779 ISI marked & Conforming to ISO:4064(I) Class B standards with IP 68 Protection Class & Have a Reed Switch For pulse output. Output is compactable for SMART meters.Water meter 80mm

1

-

-

... More
Subhead : VALVES,STRAINER AND INSULATION (E&M)

-

-

-

... More
16.11.1.6 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 65 mm dia

12

-

-

... More
16.11.1.5 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 80 mm dia

10

-

-

... More
16.11.1.4 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 100 mm dia

9

-

-

... More
16.11.1.2 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) of 150 mm dia

4

-

-

... More
CI Y Strainer 2 ½” (65mm) dia - Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects.

1

-

-

... More
CI Y Strainer 3” (80mm) dia -Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects -

2

-

-

... More
CI Y Strainer 4” (100mm) dia - Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects -

2

-

-

... More
50mm dia. (32mm thick nitrile rubber insulation)

120

-

-

... More
40mm dia. (32mm thick nitrile rubber insulation)

385

-

-

... More
32mm dia. (19mm thick nitrile rubber insulation)

700

-

-

... More
25mm dia. (19mm thick nitrile rubber insulation)

1225

-

-

... More
20mm dia. (19mm thick nitrile rubber insulation)

3100

-

-

... More
Subhead : EXTERNAL SEWERAGE & STORM WATER DRAIN

-

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 200mm OD

845

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 160mm OD

1110

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 110mm OD

475

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying,Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 75mm OD

60

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 200mm OD

100

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation) 160mm OD

200

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation) 110mm OD

100

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 20 mm nominal outer dia Pipes

75

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 25 mm nominal outer dia Pipes

50

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 32 mm nominal outer dia Pipes

100

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 40 mm nominal outer dia Pipes

20

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 50 mm nominal outer dia Pipes

140

-

-

... More
Providing and fixing uPVC Pipes, 10kg/cm² and with PN-10 Fittings, This includes jointing of pipes & fittings with one step Heavy duty uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 110 mm nominal outer dia Pipes

140

-

-

... More
Supply,installation, testing and commissioning of stainless steel coarse Screen (opening 10mm) suitable for screen chamber of size 500mmx500mm removable type including all material charges,labour transportation,loading unloading etc. Complete as per the direction of Engineer in charge.

4

-

-

... More
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With Sewer bricks conforming to IS: 4885

30

-

-

... More
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)Complete as per design

400

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

2890

-

-

... More
18.41.1A : Providing and filling sand of grading zone V or coarser grade, all - round the G.I. pipes in external workSub analysis item for sand filling component

115

-

-

... More
4.1.10 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

115

-

-

... More
Subhead : CIVIL WORK FOR RCC MANHOLE

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

318.24

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

40.28

-

-

... More
Carriage of materials by mechanical transport including loading, unloading and stacking beyond 50m initial lead up to 5km, including all lifts including all lifts involved as directed by Engineer in charge. Excavated Earth/Rock

25.58

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

28.91

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement,including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.).All works upto plinth level

33.27

-

-

... More
5.12 : Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

51.47

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

3327

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

292.5

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

186

-

-

... More
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

1800

-

-

... More
Subhead : MISCELLANEOUS ITEMS

-

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 160mm dia.

4

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 110mm dia.

1266

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 75mm dia.

10

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 50mm dia.

620

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 40mm dia.

10

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - 32mm dia.

175

-

-

... More
600 X 600 mm (24" X 24") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Light Duty (2.5 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124. For OH Water tank

6

-

-

... More
600 X 900 mm (24" X 36") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Heavy Duty (25 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124. For UG Sump

8

-

-

... More
600 X 600 mm (24" X 24") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover with frame Heavy Duty (25 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124. For UG Sump

6

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 150mm (6")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 150mm(6") uPVC Astm Sch 80 Puddle flange

4

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 100mm (4")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 100mm(4") uPVC Astm Sch 80 Puddle flange

8

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 80mm (3")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 80mm(3") uPVC Astm Sch 80 Puddle flange

9

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 65mm (2½") uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 65mm (2½") uPVC Astm Sch 80 Puddle flange

4

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 50mm (2")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 50mm(2") uPVC Astm Sch 80 Puddle flange

12

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 40mm (1½")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -40mm (1½")uPVC Astm Sch 80 Puddle flange

2

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 32mm (1¼")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 32mm 1¼"uPVC Astm Sch 80 Puddle flange

6

-

-

... More
Subhead : PLUMBING PUMPS AND HEAT PUMPS

-

-

-

... More
Vertical multi stage centrifugal pumps (surface pump) for Domestic Water Supply - Supply, Installation, Testing and Commissioning 2 nos, Vertical multi stage centrifugal pumps (surface pump) set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 12 lps @ 60 mtr head, Head range 40 to 75 mtrs (14.5 lps to 7.08 lps), ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection, Hydraulic efficiency more than 67% motor efficiency more than 85% with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) Star Delta,having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function, Digital display,Pressure gauge, Float Switches, Auto/Manuel Operation . The total system shall be assembled and tested at factory as per the duty conditions. (For Domestic Water from sump to OHT)

1

-

-

... More
Monoblock pump for Flush Water - Supply, Installation, Testing and Commissioning 2 nos, monoblock pump set, having SS/CI/BRONZE Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 5 lps @ 60 mtr head, Head range 53 to 68 mtrs ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection, Hydraulic efficiency more than 67% motor efficiency more than 85% with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) Star Delta,having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function, Digital display,Pressure gauge, Float Switches, Auto/Manuel Operation . The total system shall be assembled and tested at factory as per the duty conditions.

1

-

-

... More
Monoblock pump for Flush Water - Supply, Installation, Testing and Commissioning 2 nos, monoblock pump set, having SS/CI/BRONZE Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 5 lps @ 28 mtr head, Head range 19 to 42 mtrs ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection, Hydraulic efficiency more than 67% motor efficiency more than 85% with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) Star Delta,having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function, Digital display,Pressure gauge, Float Switches, Auto/Manuel Operation . The total system shall be assembled and tested at factory as per the duty conditions.

1

-

-

... More
Sewage Solid handling pumps - Supply, testing and commissioning of Submersible non clog Sewage Solid handling pumps. Control Panel for Controlling 2 Pumps, having SS Shaft and CI/SS Casing & Impeller, IP 68 Protection Each pumps should be capable to deliver 5 lps @ 10mtr head for each pump, solid handling 50mm with Wall mounting Microprocessor based common control Panel to operate the pumpset as ( 1Working + 1Standby ) having features of Cyclic Timer for Cascading Operation and Float Switch/Probe Suitable for Automatic Operation. The Panel should have the following Protection for Single Phase Prevention, Over Load Protection, Over /Under Voltage Protection, Dry Running Protection, Transient Surge Protection, with Auto/Manual Operation & Auto coupling . The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication(Modbus). (For Soil Tranfer Pump)

1

-

-

... More
Hydro Pneumatic system for Domestic Water Supply - Providing, Fixing, testing and commissioning Hydro Pneumatic system with 3 Nos Vertical Multistage pump set with SS Shaft, Casing, Impeller. Each pump capable to deliver 5LPS @ 20mtr head, and with 2.2kW/ 3 HP motor with 3 phase connection . Suction and Delivery of each pumps to be connected to GI manifolds of suitable size with isolation ball valves at suction & delivery and NRV at delivery of each pump. A common control panel to operate the pump set as 1 working + 1 assist + 1 standby, according to the demand. Control panel Should be with fixed speed Microprocessor with cycle based cascading system shall be of Multi Variable Speed Drive( VFD ), HMI,Star/Delta, Dry Run Protection, Overload protection, Phase reversal protection etc . The entire system to be supplied with all the pump sets and control panel assembled in a common GI Skid completely assembled and tested at factory for the duty points along with MS pressure vessel 60 ltr .

1

-

-

... More
FILTER FEED PUMP SET. Supply, Testing and Commission Filter Feed Pump Set, Submersible Type for Pumping Raw Water to Water Treatment Plant, 2 Pump System with One Working + 1 One Cyclically Stand by Pumps, each Pump of Capacity: 20M³/Hr. @ 45Mtr. Head, having SS Impeller, Shafts, Casing, with 3Ph, complete with Microprocessor Based Control Panel, for Auto and Cyclic Operation, with all Protection (Digital display, Low &high voltage protection, dry run, phase reversal, pump over load, etc.), Level Sensors / Float Switches in Treated Water & Raw Water Tanks and Control Cabling / Wiring between Level Sensors / Float Switches and Control Panel, Delivery Manifold, Isolating Valves, Non Return valves, Pressure Gauge, Fittings, Stainless Steel (Grade:304) Lifting Chains, Accessories etc. all as per Technical Specifications. The Control Panel shall be capable operating the pumps (starts and stops) by sensing the level difference in water in the Treated Water Tank. Also; capable of ‘not starting or stopping the running pumps', when the water in the underground Raw Water Tank goes below the pre-set minimum level. The Pumps to be installed in the Underground Raw Water Tank and Common Control Panel in the Pump Room, in Basement Floor, approx. 100 Mtr. away from Raw Water Tank. The Underground Power Cabling between Pumps and Control Panel and Control Cabling between Control Panel & Level Sensor / Float Switch, in the Underground Raw Water Tank, shall be measured as a part of Electrical Work. The Quoted Price for the Pump Set shall be inclusive of all above requirement, necessary Level Sensors / Float Switches, Power Cabling, Control Cabling etc, except what measured as a part of Electrical Work, as detailed above.

1

-

-

... More
Supplying, Installing, Testing & Commissioning at site hot water recirculation pump with suitable pressure switch, dry run protection & The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication( Modbus). Type : Thermostatic Controlled. Horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The shaft, impellers and chambers are made of stainless steel. The inlet and discharge parts are made of cast iron. It’s supporting up to 95 degree Celsius temperature, digital control panel with Time and Temperature settings facility. Flow for each pump in LPS : 2.3 Head in mtr : 14 Head Range : 8 - 16 mtr MOC : SS 304 Impeller Total no of pump: 1 SET ( 1Working + 1Standby )

1

-

-

... More
Supplying, Installing, Testing & Commissioning at site hot water recirculation pump with suitable pressure switch, dry run protection & The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication( Modbus). Type : Thermostatic Controlled. Horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The shaft, impellers and chambers are made of stainless steel. The inlet and discharge parts are made of cast iron. It’s supporting up to 95 degree Celsius temperature, digital control panel with Time and Temperature settings facility. Flow for each pump in LPS : 1.1 Head in mtr : 10 Head Range : 9 - 18 mtr Total no of pump: 1 SET ( 1Working + 1Standby )

2

-

-

... More
Supplying, Installing, Testing & Commissioning at site hot water recirculation pump with suitable pressure switch, dry run protection & The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication( Modbus). Type : Thermostatic Controlled. Horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The shaft, impellers and chambers are made of stainless steel. The inlet and discharge parts are made of cast iron. It’s supporting up to 95 degree Celsius temperature, digital control panel with Time and Temperature settings facility. Flow for each pump in LPS : 1.8 Head in mtr : 15 Head Range : 8 - 16 mtr Total no of pump: 1 SET ( 1Working + 1Standby )

1

-

-

... More
Supply, installation, testing & commissioning of Solar assisted Heat pump, insulated pressurised SS storage tank, hot water expansion vessel, insulated piping between the system, valves & accessories required to complete the system in position with the following specification. Solar and Heat Pump each output capacity 1000 LPH 58 Deg C required Insulated Hot Water Storage Tank suitable for 6 bar pressure SS 316 - 1no, 4000 Litre - Horizontal. COP of Heat pump 4 Circulation Pump between heat pump and storage tank, including control panel. Plumbing work Between storage tank and heat pump CPVC Pipe with suitable CPVC Fittings. Suitable Brass Fittings like NRV, Y Strainer, Air Vent, MTA, FTA, Flow Switches, Pipeline Insulation Electrical Work From Pump panel to heat pump 6 Square MM 4 core cable, 1.5 Square MM 3 core cable, 2.5 Square MM cable, Communication cable, 3 x 9Amps 3MP Contactors Coil Operated, PVC conduits for cables with suitable fittings etc., complete.

1

-

-

... More
Supply, installation, testing & commissioning of Heat pump - Insulated storage tank, hot water expansion vessel, insulated piping between the system, valves & accessories required to complete the system in position with the following specification. Heat Pump ( Working 400 LPH + Back Up 6KW Heating Coil ) - 60 Deg C. Insulated Hot Water Storage Tank suitable for 6 bar pressure Horizontal Glasslined Hot Water Tank 1000 Litre. COP of Heat pump = 4 Plumbing work Inlet and Outlet Headers DN40 CPVC Pipe with suitable CPVC Fittings. Suitable Brass Fittings like NRV, Y Strainer, Air Vent, MTA, FTA, Flow Switches, Pipeline Insulation Electrical Work From electric point to heat pump 6 Square MM 4 core cable, 1.5 Square MM 3 core cable, 2.5 Square MM cable, Communication cable, 3 x 9Amps 3MP Contactors Coil Operated, PVC conduits for cables with suitable fittings etc., Complete

2

-

-

... More
Supply, installation, testing & commissioning of Heat pump -Insulated storage tank, hot water expansion vessel, insulated piping between the system, valves & accessories required to complete the system in position with the following specification. Heat Pump ( Working 600 LPH + Back Up 9KW Heating Coil ) - 60 Deg C. Insulated Hot Water Storage Tank suitable for 6 bar pressure Horizontal Glasslined Hot Water Tank - 1no, 1500 Litre in-Built in Heat pump. COP of Heat pump = 4 Plumbing work Inlet and Outlet Headers DN40 CPVC Pipe with suitable CPVC Fittings. Suitable Brass Fittings like NRV, Y Strainer, Air Vent, MTA, FTA, Flow Switches, Pipeline Insulation Electrical Work From electric point to heat pump 6 Square MM 4 core cable, 1.5 Square MM 3 core cable, 2.5 Square MM cable, Communication cable, 3 x 9Amps 3MP Contactors Coil Operated, PVC conduits for cables with suitable fittings etc., Complete

1

-

-

... More
Subhead : WATER TREATMENT PLANT

-

-

-

... More
Supply, Installation, testing and commission Water Pre-Treatment Plant Capacity: 20M3 /Hr, for continuous operation of 10 Hr, complete with High Pressure Sand Filter, Activated Carbon Filter,with Multiport valves, Chemical Dosing etc as per final requirement, connected Pipe Work etc, all as per Technical Specifications.Filter Feed Pumps shall be measured seperately.

1

-

-

... More
Subhead : SEWAGE TREATMENT PLANT - 300 KLD

-

-

-

... More
Supply, installation, testing, commissioning and operation of Sewage Treatment Plant of 300 KLD capacity as per the detailed specification in Part C detailed below

1

-

-

... More
HT & LT ELECTRICAL WORKS - Subhead : Electrical System

-

-

-

... More
1010KVA DIESEL GENERATORSupply, Installation, Testing &commissioning of ;Silent Type; Diesel Generating Sets along with acoustic enclosure having Prime Power Rating of 800KW at 1500 RPM 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 Phase system for 0.85 Load factor (Detailed Technical Specification Attached)

2

-

-

... More
500KVA DIESEL GENERATOR;Supply, Installation, Testing &commissioning of Silent Type' Diesel Generating Sets along with acoustic enclosure having Prime Power Rating of 400KW at 1500 RPM 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 Phase system ; for 0.85 Load factor (Detailed Technical Specification Attached)

2

-

-

... More
EXHAUST PIPES;Supplying and fixing exhaust gas piping of suitable dia, welded black M.S B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust.For 1010kVA DG Set

240

-

-

... More
EXHAUST PIPES;Supplying and fixing exhaust gas piping of suitable dia, welded black M.S B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.For 500kVA DG Set

120

-

-

... More
3Nos. x 120KVA UPS;SITC of 3Nos. of 120 KVA UPS at 0.9 PFof 415V, (+10%-15%), 3phase input and 3 phase output with 30minutes battery backup for individual UPS operates in Parallel Redundant System, including surge protection system with necessary copper cabling between UPS and batteries (SMF batteries of Reputed Make)/ battery breaker, inbuilt Isloation Transformer or provision for transformer at outside, BMS compatibility, SNMP Card for network monitoring, Static power converters, Radio interference suppression, harmonic filter & all accessories required to complete the system configuration with high performance and less wave form distortion. It shall be 100% generator compatabile, with efficiency 94% and output power factor 0.9, display/ control panel, non compensated LC filter, high efficiency, static bypass, with all required accessories including all labour charges etc. complete as per the specification and requirement of site conditions.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. The system shall be true online double - conversion DSP based UPS system connected in parallel redundant load sharing configuration with each UPS unit having inbuilt parallel kit and also each UPS shall be with automatic &manual bypass switch capable of working in standalone configuration also. The system shall have IGBT rectifier and inverter as required. The acoustic noise of the system should be less than 60dB. UPS shall be housed in a sheet steel enclosure fabricated out of 2mm thick CRCA sheet indoor IP20 Degree of protection. The enclosure shall be treated using 7 tank process and shall be given powder coated finish.

1

-

-

... More
3Nos. x 60KVA UPS SITC of 3Nos. of 60 KVA UPS at 0.9 PFof 415V, (+10%-15%), 3phase input and 3 phase output with 30minutes battery backup for individual UPS operates in Parallel Redundant System, including surge protection system with necessary copper cabling between UPS and batteries (SMF batteries of Reputed Make)/ battery breaker, inbuilt Isloation Transformer or provision for transformer at outside, BMS compatibility, SNMP Card for network monitoring, Static power converters, Radio interference suppression, harmonic filter &all accessories required to complete the system configuration with high performance and less wave form distortion. It shall be 100% generator compatabile, with efficiency 94% and output power factor 0.9, display/ control panel, non compensated LC filter, high efficiency, static bypass, with all required accessories including all labour charges etc. complete as per the specification and requirement of site conditions.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. The system shall be true online double - conversion DSP based UPS system connected in parallel redundant load sharing configuration with each UPS unit having inbuilt parallel kit and also each UPS shall be with automatic & manual bypass switch capable of working in standalone configuration also. The system shall have IGBT rectifier and inverter as required. The acoustic noise of the system should be less than 60dB. UPS shall be housed in a sheet steel enclosure fabricated out of 2mm thick CRCA sheet indoor IP20 Degree of protection. The enclosure shall be treated using 7 tank process and shall be given powder coated finish

1

-

-

... More
3Nos. x 30KVA UPSSITC of 3Nos. of 30 KVA UPS at 0.9 PFof 415V, (+10%-15%), 3phase input and 3 phase output with 30minutes battery backup for individual UPS operates in Parallel Redundant System, including surge protection system with necessary copper cabling between UPS and batteries (SMF batteries of Reputed Make)/ battery breaker, inbuilt Isloation Transformer or provision for transformer at outside, BMS compatibility, SNMP Card for network monitoring, Static power converters, Radio interference suppression, harmonic filter & all accessories required to complete the system configuration with high performance and less wave form distortion. It shall be 100% generator compatabile, with efficiency 94% and output power factor 0.9, display/ control panel, non compensated LC filter, high efficiency, static bypass, with all required accessories including all labour charges etc. complete as per the specification and requirement of site conditions.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. The system shall be true online double - conversion DSP based UPS system connected in parallel redundant load sharing configuration with each UPS unit having inbuilt parallel kit and also each UPS shall be with automatic & manual bypass switch capable of working in standalone configuration also. The system shall have IGBT rectifier and inverter as required. The acoustic noise of the system should be less than 60dB. UPS shall be housed in a sheet steel enclosure fabricated out of 2mm thick CRCA sheet indoor IP20 Degree of protection. The enclosure shall be treated using 7 tank process and shall be given powder coated finish.

1

-

-

... More
Supply, installation, testing and commissioning of dust and vermin proof floor mounted free standing cubicle type, 11kV, extensible panel board made out of 14 SWG thick CRCA sheet fully compartmentalized complete with hinged and earthed front doors interlocked with the earth switch, comprising of One numbers of 630A VCB as incomer and four numbers of 630A VCB as outgoings as per the specification details below including providing station class polymeric type surge arrestor (10kA) for incomer with necessary switch for protection of same. Outgoings to be provided with over current + Earth fault relays with high set element, auto relays for door-interlock, provided with winding temperature alarm/trip etc.Each VCB panel also include POWER PACK/UPS of required capacity for auxiliary power supply unit with all accessories required for complete installation as required and providing all connection and interconnections as required and as instructed by engineer in charge/consultant.;INCOMER:1no:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection & metering.;Draw out type resin cast P.T with inbuilt fuses of ratio 11kV/110V, CL : 0.5, must be provided. Bus bar compartment shall have suitable capacity non-hygroscopic and high dielectric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. Metering compartment for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release (Not required), RYB indication lamps, cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar & CB truck enclosures and powder coating complete panel as per IS-2516 & IS 3427 with latest amendments complete as required with manually charged spring closing system. It shall also be provided with Instantaneous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. CT Rating as per the Electrical Scheme.OUTGOING:4 Nos:-11kV 630A, 3phase 50Hz, 350MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection. Draw out type resin cast P.T with inbuilt fuses of ratio 11kV/110V, CL : 0.5, must be provided. Bus bar compartment shall have suitable capacity non-hygroscopic and high dielectric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. Metering compartment for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release (Not required), RYB indication lamps, cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar & CB truck enclosures and powder coating complete panel as per IS-2516 & IS 3427 with latest amendments complete as required with manually charged spring closing system. It shall also be provided with Instantaneous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. CT Rating as per the Electrical Scheme.

1

-

-

... More
2000KVA - 11kV/433V Cast Resin (Dry type) Laser Scribed TransformerSupply, installation, testing &commissioning of 1No. of 2000kVA 11kV/433V indoor cast resin dry type transformer with laser scribed core and copper winding, connected Delta on HT side and Star on LT side with tapping +5% to -15% in steps of 1.25% by tap links, include separate winding temperature indicator for each phase and core in theTransformer. Insulation Class F Transformer should have cable end box on HV side and suitable adaptor box on LV side for connecting 3200A AL BBT, with all accessories, complete as required and losses as per ECBC, IE rules specifications. The transformer shall confirm to IS 2026, 11171/1985 with latest amendment etc complete. (Detailed Technical Specification Attached)

2

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity outdoor type Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints &expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos CU strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. ;1600 amps 50 KA Sc for 1 sec

60

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity outdoor type Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos CU strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. 3200 amps 65 KA Sc for 1 sec

60

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Indoor type Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos CU strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. ;2000 amps 50 kA Sc for 1 sec

100

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity outdoor type Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos CU strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. ;1250 amps 50 KA Sc for 1 sec

30

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Indoor type Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints &expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos CU strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.3200 amps 65 KA Sc for 1 sec

200

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Indoor type Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints &expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos CU strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. ;1000 amps 50 KA Sc for 1 sec

40

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Indoor type Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos CU strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. 1600 amps 50 kA Sc for 1 sec

30

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Indoor type Sandwich Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints &expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos CU strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. ;1250 amps 50 KA Sc for 1 sec

100

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Indoor type Sandwich Type rising main for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply in convenient section complete with 4 Nos aluminium bus bars, necessary joints, elbow joints & expansion joints and bends, adopter box and copper flexible for joints, continuous earthing with 2 Nos CU strip of suitable size( one on each side) including G.I clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. ;1250 amps 50 kA SC for 1 sec;

220

-

-

... More
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Indoor type N feed unit suitable for Sandwich Type rising main for use on 3 phase 4 wire 415 volts, 50 Hz A.C.supply made with 0.6 mm thick electro galvanised sheet steel enclosure IP54 complete with necessary joints including clamping brackets ,angle iron bracket,steel fasteners ,connecting to earth system etc as required.the end feed unit shall comply with IEC and BS standard .the routine test certificate as per IS/IEC and type test certificate of end feed unit shall be furnished1250 amps 50 kA FP,EDO,thermal magnetic release ACB

4

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. ;630A, 25kA, FP, Thermal Magnetic MCCB in Tap off box

8

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. ;400A, 25kA, FP, Thermal Magnetic MCCB in Tap off box

28

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. ;200A, 25kA, FP, Thermal Magnetic MCCB in Tap off box

2

-

-

... More
Fabrication, supply, erection, testing and commissioning of TTA type, Indoor Cubicle , dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.The panel shall be with PLC components with load manager for interlocking of incoming breakers & bus couplers, UPS for PLC and all connections and interconnections required for PLC Logic Operations for interlocking of breakers as indicated in schematic.MSB (Extensible)Incomer A & D : 3200, FP, MP, EDO, 65kA ACB with 3 O/C and 1 E/F release. standby low set E/F Protection using CT at Neutral earthing conductor "Metering & Relay;(a) Multifunction energy meter / LM with communication port to display the Voltage ,Current ,Power ,Frequency ,Power factor, THD and Maximum Demand with the necessary CT's;(b) Low set earth fault protection relay (51G )with suitable CT;(c) Restricted Earth fault Relay (64) with 10%-40% setting range with suitable CT t;(d)Winding Temp.Alarm & Trip (26 WT);(d) 2nos suitable CT for APFC Relay;(e) Over Voltage Relay (59) (g) RYB indication lamp with 2A MCBs;(h) ON OFF Trip Indication 2A MCBs(g)Annunciator<br>Incomer B & ;3200, FP, MP, EDO, 65kA ACB with overload & E/F release & standby low set E/F protection using CT at neutral earthing conductor&;Meters & Relays:t;(h) RYB indication lamp with 2A MCBs<br>Bus coupler C : 3200A FP 415V,65kA EDO ACB <br>Surge Protection Device:This panel should include Bus bar mounting Surge Protection Device Class B & Class C/ Class 1 & Class 2 Tested as per IEC 61643 Part 11:2011 ; UL 1449 4th edition . Nominal voltage -230V 50/60Hz, MCOV of 350 V , Total Impulse current-100 kA (10/350µ sec) & Total Max Discharge current 800kA (8/20µ sec), Voltage protection level 1.2 kV . The Surge Protection Devices should have TOV withstand for 120 Min : 528 V and with out Follow Current & Leakage Current. Protective Elements are a single, heavy duty, distribution grade Metal Oxide Varistor (MOV) disk, assembled under pressure in an environmentally sealed aluminum casing. & the Protection Modes for : L & N to PE . The connections (Three Lines & Neutral) should be directly connected to Protective Earth Terminal for better response time. Short- Circuit Current rating (Isccr) – 65 kA/50 Hz . With in built Back up fuse. Total Response time <1 nano sec . <br>PLC Based Controller for interlocking and Auto switching<br>Out going:<br>630A TPN ISO-1 No<br>2000A,50kA FP EDO MP ACB -2<br>1250A,50kA FP EDO MP ACB -9<br>1000A,50kA FP EDO MP ACB -2<br>800A,50kA FP EDO MP ACB -8<br>630A,50kA TPN MP MCCB -10<br>All MCCB's are microprocessor based with Rotary operated handle and necessary accessories;Busbar: 1 Set TPN AL bus bars suitably rated for 3200A

1

-

-

... More
DG SYNCH PANEL-1 Fabrication, supply, erection, testing and commissioning of TTA, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. ;The panel shall be with PLC components for Synchronization of 2Nos. of 1010KVA DG Sets and 2 Nos of 500kVA DG Sets, Auto Load Sharing, AMF which includes synchronizing relays, UPS for PLC and all connections and interconnections required for synchronizing and load sharing for 4 nos. of DG sets and individual Generator selection and control facilities as well as mimic diagram. Details as per Technical specification attached.

1

-

-

... More
MAIN UPS PANEL;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomers :800A 50kA FP EDO MP ACB. - 2NoMeters: ;(a)Digital meter with displays of voltage ¤t with necessary CTs-2 set;(b)RYB indication lamp with 2A SP MCB - 1No.Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as RequiredOut going :630A TP+N TM MCCB(Ics 36kA) -2 Nos;320A TP+N TM MCCB(Ics 36kA) -4 Nos&Busbar: 1 Set TPN Al. bus bars suitably rated for 800A

1

-

-

... More
HVAC PANEL-2 - (PHASE-II)Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Incomers :1250A 50kA FP EDO MP ACB. - 2No; Meters: (a)Digital meter with displays of voltage & current with necessary CTs-2 set ;(b)RYB indication lamp with 2A SP MCB - 1No. ;Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required Out going :1000A TP+N MP ACB(Ics 36kA) -3 Nos 630A TP+N MP MCCB(Ics 36kA) -1 Nos;Busbar: 1 Set TPN Al. bus bars suitably rated for 1250A

1

-

-

... More
HVAC PANEL-1 Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.Incomers : 2000A 50kA FP EDO MP ACB. - 2NoMeters: ;(a)Digital meter with displays of voltage & current with necessary CT's-2 set (b)RYB indication lamp with 2A SP MCB - 1No.;Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required Out going :1000A 36kA TPN MP ACB-4 nos 630A TP+N MP MCCB(Ics 36kA) -3 Nos ;Busbar: 1 Set TPN Al. bus bars suitably rated for 2000A

1

-

-

... More
COMMON PANELFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomers :1000A 50kA FP EDO MP ACB. - 1No Meters: (a)Digital meter with displays of voltage & current with necessary CT'<br>(b)RYB indication lamp with 2A SP MCB - 1No.;Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required<br>Out going :;500A TP+N MP MCCB(Ics 36kA) -1 Nos;320A TP+N MP MCCB(Ics 36kA) -5 Nos;250A TP+N MP MCCB(Ics 36kA) 2Nos;Busbar: 1 Set TPN Al. bus bars suitably rated for 1000A

1

-

-

... More
MEDICAL PANEL-1;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :;1250A 50kA FP EDO MP ACB. -1No;Meters: (a)Digital meter with displays of voltage & current with necessary CT&;s-1 set (b)RYB indication lamp with 2A SP MCB - 1No.Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Requiredt;Out going : ;320A TP+N MP MCCB(Ics 36kA) -10 Nos;Busbar: 1 Set TPN Al. bus bars suitably rated for 1250A

1

-

-

... More
;MEDICAL PANEL-2 - (PHASE-II);Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.Incomer :1000A 50kA FP EDO MP ACB. -1No;;Meters: ;(a)Digital meter with displays of voltage & current with necessary CT;s-1 set;(b)RYB indication lamp with 2A SP MCB - 1No.&;Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Requiredt;Out going : ;320A TP+N MP MCCB(Ics 36kA) -9 Nos;Busbar: 1 Set TPN Al. bus bars suitably rated for 1000A

1

-

-

... More
APFC PANEL-400KVAR;Fabrication, supply, erection, testing and commissioning of PTTA Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.APFC PANEL - With inbuilt solid state automatic power factor correction arrangement having microprocessor based control circuit and contactor switching power circuit having a required capacity of 400KVAR having capacitor bank in steps of [(4x50KVAR)+(6x25 KVAR)+(3x10 KVAR)]+fixed capacitor of (1x20KVAR), including main MCCB, MCBs APFC relay, contactors, Reactors, capacitors, indicating lamps, etc.complete with all necessary hardware &accessories &;Incomer:800A FP MCCB 50kA - 1 No.Meters &relays.(a)Multifunction digital meter with displays for (V,I)with necessary CT;s-1 No.(b)RYB indication lamp with 2A SP MCB - 1 No.14 stage APFC relay 1 -N o;Outgoing:-;160A TP MP MCCB ,36kA - 4 Nos.;63A TP MP MCCB, 36kA - 10Nos.;Capacitor Bank: 50 kVAR(APP -525v) with capacitor duty contactor &; 7% detuned reactor - 4 No.Capacitor Bank: 25 kVAR(APP -525v) with capacitor duty contactor & 7% detuned reactor - 6 No.Capacitor Bank: 10 kVAR(APP -525v) with capacitor duty contactor & 7% detuned reactor - 3 No.;Capacitor Banks: 20kVAR(APP -525v) - 1 Nos.;All MCCB are with Rotary operated handle and all necessary accessories.;ON/Off indication lamp for each capacitor bank and necssary cooling fan to be provided&;Busbar: 1 Set TPN AL busbar suitably rated for 800A

4

-

-

... More
MAIN LIFT PANELFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :320 A, 36 kA, TPN TM MCCB - 1 no.Meters &relays.;(a)Multifunction digital meter with displays for (V,I)with necessary CT;s-1 No.;(b)RYB indication lamp with 2A SP MCB - 1 SetOut Goings :160 A 16 kA, TPN MP Based MCCB - 4no125 A 16 kA, TPN MP Based MCCB - 1 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 320A

1

-

-

... More
;EMERGENCY PANEL&;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :250 A, 4P ATS - 1 no+250 A 25 kA, FP TM MCCB1 no.;Meters &relays.(b)RYB indication lamp with 2A SP MCB - 2 Set;Out Goings :;125 A 25 kA, TPN TM MCCB - 3 no.100 A 25 kA, TPN TM MCCB - 4no.Surge Arrester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mounting type etc. Complete with Backup Fuse as RequiredBusbar: 1 Set TPN AL bus bars suitably rated for 250A

1

-

-

... More
EMERGENCY LIFT PANEL;Fabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;;Incomer :125 A,25 kA FPTM based MCCB - 1 no.;Meters &; relays.;(b)RYB indication lamp with 2A SP MCB - 1 SetOut Goings :;63 A 16 kA, TP+N TM MCCB - 5 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 125A

1

-

-

... More
;LIFT PANEL-2Fabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.Incomer :<br>125 A, 25 kA FP TM MCCB - 1 no.t;Meters &relays.;(b)RYB indication lamp with 2A SP MCB - 1 SetSurge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required;Out Goings :;63 A , 16 kA ,TP+N MCCB - 2 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 125A

1

-

-

... More
LIFT PANEL-3Fabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer :;160 A, 25 kA TPN TM MCCB - 1 no.Meters & relays.(b)RYB indication lamp with 2A SP MCB - 1 Set;Surge Arrester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mounting type etc. Complete with Backup Fuse as Required;Out Goings :;63 A , TPN MCCB Isolator - 4 no.Bus bar: 1 Set TPN AL bus bars suitably rated for 160A

1

-

-

... More
LIFT PANEL-4<br>Fabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.Incomer :;160 A, 25 kA FP TM MCCB - 1 no.;Meters &relays.;(b)RYB indication lamp with 2A SP MCB - 1 SetSurge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required Out Goings :63 A , TPN MCCB - 3 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 160A LIFT PANEL-4;Fabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer 160 A, 25 kA FP TM MCCB - 1 no.t;Meters & relays.t(b)RYB indication lamp with 2A SP MCB - 1 SetSurge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required;Out Goings :63 A , TPN MCCB - 3 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 160A

1

-

-

... More
LIFT PANEL-5Fabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout providedIncomer :160 A, 25 kA FP TM MCCB - 1 no.;Meters &a relays.;(b)RYB indication lamp with 2A SP MCB - 1 Set;Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required;Out Goings ;63 A , TP+N MCCB - 4 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 160A

1

-

-

... More
LIFT SUB PANELSFabrication, supply, erection, testing and commissioning of Indoor Cubicle Type, dust and vermin proof, Wall/floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :;63 A, 16 kA FP MCCB Isolator- 1 no.Meters &; relays.;(b)RYB indication lamp with 2A SP MCB - 1 Sett;Out Goings :63 A , 300 mA 4P RCBO - 1 no.;25 A, 30 Ma 2P RCBO - 1 no.;6A, 30 mA SP MCB - 4 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 63A

16

-

-

... More
PLUMBING PANEL-1t;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer :250 A, TPN Isolator - 1 no.;Meters &; relays;(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.(b)RYB indication lamp with 2A SP MCB - 1 SetSurge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required;Out Goings 100 A 16 kA, TPN MP Based MCCB - 3 no.63 A 16 kA, TPN TM MCCB - 1 no.&32 A 16 kA, TPN TM MCCB - 4 no.;16 A 16 kA, TPN TM MCCB - 5 no;Busbar: 1 Set TPN AL bus bars suitably rated for 250A

1

-

-

... More
PLUMBING PANEL-2&;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer :&t;320 A, TPN Isolator - 1 no.;Meters & relays.<br>(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.<br>(b)RYB indication lamp with 2A SP MCB - 1 SetSurge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required;Out Goings :;100 A 16 kA, TPN MP Based MCCB - 2 no.;100 A 16 kA, TPN TM MCCB - 1 no.;63 A 16 kA, TPN TM MCCB - 2 no.;16 A 16 kA, TPN TM MCCB - 4 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 320A

1

-

-

... More
POWER LAUNDRY PANELFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalize as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.Incomer - 250A FP 25kA Thermal Magnetic Release MCCB - 1No.250A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. ;Prewired digital meter module including all meters and indicating lamps - 1 No;Cable alley - 2 NosClass B+C / Class 1 + 2 Surge arrester device with necessary MCB for back-up protection - 1 No.Outgoings100A, 16kA, TP+NL, Thermal Magnetic Release Based MCCB - 4 Nos.63A, 16kA, TP+NL, Thermal Magnetic Release Based MCCB - 2 No.;Supply, Installation, testing and commissioning.

1

-

-

... More
MEDICAL GAS PLANT PANEL Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer - 125A FP 25kA Thermal Magnetic Release MCCB - 1No.;125A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Prewired digital meter module including all meters and indicating lamps - 1 No;Cable alley - 2 NosClass B+C / Class 1 + 2 Surge arrester device with necessary MCB for back-up protection - 1 No.t;Outgoings40A, 16kA, TP+NL, Termal Magnetic Release Based MCCB - 2 Nos.32A, 16kA, TP+NL, Termal Magnetic Release Based MCCB - 4 NosSupply, Installation, testing and commissioning

1

-

-

... More
CSSD PANEL Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer - 250A FP 25kA Thermal Magnetic Release MCCB - 1No.250A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. ;Prewired digital meter module including all meters and indicating lamps - 1 NoCable alley - 2 NosClass B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No.;Outgoings100A, 16kA, TP+NL, Thermal Magnetic Release Based MCCB - 4 Nos63A, 16kA, TP+NL, Thermal Magnetic Release Based MCCB - 2 Nos.;Supply, Installation, testing and commissioning.

1

-

-

... More
EMERGENCY LIGHTING PANEL: Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.&;Incomer : 63 A,25 kA TM FP MCCB - 3 Nos;Meters & relays.(a)Multifunction digital meter with displays for (V,I)with necessary CT&s-3 No.(b)RYB indication lamp with 2A SP MCB - 03 Set;Out Goings :;32 A 16 kA, TP+N MP Based MCCB - 12 no.;Busbar: 1 Set FP AL bus bars suitably rated for 63A

1

-

-

... More
MEDICAL UPS I/P PANELFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.&Incomer :630 A, 36kA FP TM Based MCCB - 2 no;Meters &;(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-2 No.;(b)RYB indication lamp with 2A SP MCB - 2 Sett;Out Goings :250 A 25 kA, TP+N MP Based MCCB - 5 no;Busbar: 1 Set FP AL bus bars suitably rated for 630A

1

-

-

... More
;MEDICAL UPS O/P PANELFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.Incomer :<br>250 A, 25kA FP TM Based MCCB - 5 no.Meters & relays.(a)Multifunction digital meter with displays for (V,I)with necessary CT;s- 4 No.t;(b)RYB indication lamp with 2A SP MCB - 4 Set&t;Out Goings ;250 A 16 kA, TP+N MP Based MCCB - 2 no.160 A 16 kA, TP+N TM MCCB - 2 no.100 A 16 kA, TP+N TM MCCB - 3 no.63 A 16 kA, TP+N TM MCCB - 4 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 630A

1

-

-

... More
IT UPS I/P PANEL;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :320 A, 36kA FP MP Based MCCB - 2 no.;Meters &relays.(a)Multifunction digital meter with displays for (V,I)with necessary CT;s-2 No.(b)RYB indication lamp with 2A SP MCB - 2 Set;Out Goings :;125 A 25 kA, TP+N MP Based MCCB - 5 no.Busbar: 1 Set TPN AL bus bars suitably rated for 320A

1

-

-

... More
IT UPS O/P PANELFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer :;160 A, 25kA TPN TM MCCB - 3 no.Meters & relays.;(a)Multifunction digital meter with displays for (V,I)with necessary CT&rs -3 No.t;(b)RYB indication lamp with 2A SP MCB - 3 Set&t;Out Goings :100 A 16 kA, TPN MP TM MCCB - 2 no.;80 A 16 kA, TPN MP Based MCCB - 1 no.63 A 16 kA, TPN MP Based MCCB - 3 no.32 A 16 kA, TPN MP Based MCCB - 6 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 320A

1

-

-

... More
LG1-SSB;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;;Incomer :400 A, 36 kA, 4P TM MCCB - 1 no.Meters ; relays.;(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.(b)RYB indication lamp with 2A SP MCB - 1 Set.t;Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as RequiredOut Goings :160 A 25 kA, TP+N MP MCCB - 1 no.125 A 25 kA, TP+N MP MCCB - 1 no.100 A 25 kA, TP+N MP Based MCCB - 1 no.;63 A 25 kA, TP+N TM MCCB - 1 no.63 A 25 kA, TP+N MP Based MCCB - 4 no.50 A 25 kA, TP+N TM MCCB - 3 no40 A 25 kA, TP+N TM MCCB - 1 no.Busbar: 1 Set TPN AL bus bars suitably rated for 400A

1

-

-

... More
LG2-SSB;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.&ncomer :t;200 A, 36 kA, FP TM MCCB - 1 no.Meters & relays(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.;(b)RYB indication lamp with 2A SP MCB - 1 Set&lOut Goings :;160 A 25kA, TP+N MP MCCB - 1 no.100 A 25 kA, TP+N TM MCCB - 1 no.;80 A 25 kA, TP+N TM MCCB - 1 no.63 A25 kA, TP+N TM MCCB - 3 no.;50 A 25 kA, TP+N TM MCCB - 1 no.;40 A 25 kA, TP+N TM MCCB - 1 no.;Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required;Busbar: 1 Set TPN AL bus bars suitably rated for 200A

1

-

-

... More
GF-SSBt;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :t;630 A, 36 kA, 4P TM MCCB - 1 noMeters & relays.t;(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.;(b)RYB indication lamp with 2A SP MCB - 1 Set.<br>Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required<br>Out Goings :200 A 25 kA, TP+N MP MCCB - 3 no.160 A 25 kA, TP+N MP MCCB - 7 no.00 A 25 kA, TP+N MP MCCB - 4 no.;100 A 25 kA, TP+N TM MCCB - 2 no.&t;80 A 25 kA, TP+N MP MCCB - 7 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 630A

1

-

-

... More
;1F-SSB<Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :;400 A, 36 kA, FP TM MCCB - 1 no;Meters & relays.t;(a)Multifunction digital meter with displays for (V,I)with necessary CT&s-1 No.;(b)RYB indication lamp with 2A SP MCB - 1 Set.Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required;Out Goings :t;200 A 25 kA, TP+N MP MCCB - 1 no.<br>160 A 25 kA, TP+N MP MCCB - 1 no.160 A 25 kA, TP+N TM MCCB - 3 no.t;63 A 25 kA, TP+N MP MCCB - 2 no.63 A 25kA, TP+N TM MCCB - 2 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 400A

1

-

-

... More
;2F-SSB&Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.&ncomer :;400 A, 36 kA, FP TM MCCB - 1 no.t;Meters & relays.(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.;(b)RYB indication lamp with 2A SP MCB - 1 Set.<br>Surge Arrester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mounting type etc. Complete with Backup Fuse as Required&;Out Goings :160 A 16 kA, TPN MP MCCB - 1 no.160 A 16 kA, TPN TM MCCB - 1 no.100 A 16 kA, TPN MP MCCB - 1 no.&;100 A 16 kA, TPN TM MCCB - 2 no.;63 A 16 kA, TPN TM MCCB - 2 no.63 A 16 kA, TPN MP MCCB - 2 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 400A ;

1

-

-

... More
3F-SSB&;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.Incomer :;400 A,36 kA, FP TM MCCB - 1 no.Meters & relays.;(a)Multifunction digital meter with displays for (V,I)with necessary CTs-1 No.;(b)RYB indication lamp with 2A SP MCB - 1 Set.;Out Goings :;200 A 25 kA, TP+N TM MCCB - 1 no.;125 A 25 kA, TP+N TM MCCB - 2 no100 A 25 kA, TP+N TM MCCB - 2 no100 A 25 kA, TP+N MP MCCB - 1 no.;63 A 25 kA, TP+N MP MCCB - 2 no.;50 A 25 kA, TP+N TM MCCB - 2 no.;Surge Arrester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mounting type etc. Complete with Backup Fuse as Required;Busbar: 1 Set TPN AL bus bars suitably rated for 400A

1

-

-

... More
4F-SSBFabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :;400 A, 36 kA, FP TM MCCB - 1 nO;Meters &relays.&;(a)Multi function digital meter with displays for (V,I)with necessary CTS-1 No.t;(b)RYB indication lamp with 2A SP MCB - 1 SetOut Goings :;200 A 16 kA, TPN MP MCCB - 1 no.;160 A 16 kA, TPN TM MCCB - 1 no.&125 A 16 kA, TPN TM MCCB - 1 no.;100 A 16 kA, TPN MP MCCB - 2 no.;50 A 16 kA, TPN TM MCCB - 4 no;50 A 16 kA, TPN MP MCCB - 1 no.;Surge Arrester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mounting type etc. Complete with Backup Fuse as Required;Busbar: 1 Set TPN AL bus bars suitably rated for 400A

1

-

-

... More
5F-SSB<Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer :;630 A, 36 kA, FP TM MCCB - 1 no.t;Meters &a; relays.<br>(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No;(b)RYB indication lamp with 2A SP MCB - 1 Set.Surge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Required<br>Out Goings :<br>200 A 25 kA, TP+N MP Based MCCB - 3 no.<br>160 A 25 kA, TP+N MP Based MCCB - 1 no.125 A 25 kA, TP+N TM MCCB - 1 no.;100 A 25 kA, TP+N TM MCCB - 3 no.;100 A 25 kA, TP+N MP MCCB - 2 no. Busbar: 1 Set TPN AL bus bars suitably rated for 630A

1

-

-

... More
GF-IT UPS SUB PANEL ;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.Incomer :80 A, 16 kA, FP TM MCCB - 1 not;Meters &; relays.(a)Multifunction digital meter with displays for (V,I)with necessary CT-1 No.(b)RYB indication lamp with 2A SP MCB - 1 Set.Out Goings40 A 16 kA, TPN TM MCCB - 3 no.t;32 A 16 kA, TPN TM MCCB - 5 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 80A

1

-

-

... More
1F-IT UPS SUB PANEL Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :;100 A, 16 kA, FP TM MCCB - 1 no.;Meters & relays.(a)Multi function digital meter with displays for (V,I)with necessary CT’s-1 No.gt;(b)RYB indication lamp with 2A SP MCB - 1 Set.;Out Goings :;32 A 16 kA, TPN TM MCCB - 10 no.;Busbar: 1 Set TPN TM AL bus bars suitably rated for 100 A

1

-

-

... More
;2F-IT UPS SUB PANEL Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer :<br>100 A, 16 kA, FP TM MCCB - 1 no.<br>Meters & relays.&;(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.(b)RYB indication lamp with 2A SP MCB - 1 Set.<br>Out Goings :<br>32 A 16 kA, TPN TM MCCB - 7 no.<br>Busbar: 1 Set TPN TM AL bus bars suitably rated for 100 A

1

-

-

... More
;1F-MEDICAL UPS SUB PANEL<br>Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer :<br>100 A, 16 kA, TPN TM MCCB - 1 no.<br>Meters & relays.<br>(a)Multifunction digital meter with displays for (V,I)with necessary CT;s-1 No.;(b)RYB indication lamp with 2A SP MCB - 1 Set.;Out Goings :<br>40 A 16 kA, TPN TM MCCB - 3 no.<br>32 A 16 kA, TPN TM MCCB - 2 no.&Busbar: 1 Set TPN AL bus bars suitably rated for 100 A

1

-

-

... More
;2F-MEDICAL UPS SUB PANEL<br>Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer :<br>160 A, 16 kA, TPN TM MCCB - 1 no;Meters & relays.<br>(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.<br>(b)RYB indication lamp with 2A SP MCB - 1 Set.<br>Out Goings :t;40 A 16 kA, TPN TM MCCB - 8 not;Busbar: 1 Set TPN AL bus bars suitably rated for 160 A

1

-

-

... More
;3F-MEDICAL UPS SUB PANEL<br>Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :<br>80 A, 16 kA, FP TM MCCB - 1 no.t;Meters &a; relays.<br>(a)Multi function digital meter with displays for (V,I)with necessary CT’s-1 Nogt;(b)RYB indication lamp with 2A SP MCB - 1 Set.;Out Goings :;40 A 10 kA, TPN TM MCCB - 1 no.<br>32 A 10 kA, TPN TM MCCB - 4 no.<br>Busbar: 1 Set FP AL bus bars suitably rated for 80 A

1

-

-

... More
5F-MEDICAL UPS SUB PANEL;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided."<br>Incomer :250 A, 16kA 4P Automatic Transfer Switch - 1 no.t;Meters & relays.;(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.(b)RYB indication lamp with 2A SP MCB - 2 Set.;Out Goings :t;125 A 16 kA,TPN TM MCCB - 3 no63 A 16 kA, TPN TM MCCB - 2 no;40 A 16 kA, TPN TM MCCB - 4 no.&32 A 16 kA, TPN TM MCCB - 2 no.;Busbar: 1 Set TPN AL bus bars suitably rated for 250 A ;

1

-

-

... More
1F-POWER SUB PANEL;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all assecories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.&Incomer :;160 A, 16kA, TPN TM MCCB - 1 noMeters & relays.;(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.;(b)RYB indication lamp with 2A SP MCB - 1 Set.<br>Out Goings :&l;50 A 16 kA, TPN TM MCCB - 6 no.32 A 16 kA, TPN TM MCCB - 2 not;Busbar: 1 Set TPN AL bus bars suitably rated for 160A

1

-

-

... More
;Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.;Incomer :125A, 25kA 4P TM MCCB - 1 no.;Meters & relays.;(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No;(b)RYB indication lamp with 2A SP MCB - 1 Set.;Out Goings 63 A 16 kA, TPN TM MCCB - 6 no..Busbar: 1 Set FP AL bus bars suitably rated for 125A

6

-

-

... More
5F OT Panel 1 &2 Fabrication, supply, erection, testing and commissioning of TTA PANEL, Indoor Cubicle Type, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized as per Form 4B Construction complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel for cable end termination including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided.&Incomer :125 A, 16 kA, FP TM MCCB - 1 no.&l;Meters &relays;;(a)Multifunction digital meter with displays for (V,I)with necessary CT’s-1 No.;(b)RYB indication lamp with 2A SP MCB - 1 SetSurge Arester Class B+C / Class 1+2 as per IEC 61643(IP 20) Din rail Mouting type etc. Complete with Backup Fuse as Requiredt;Out Goings :;63 A 16 kA, TPN MP based MCCB - 8 no.Busbar: 1 Set FP AL bus bars suitably rated for 125A

2

-

-

... More
Supply, erection, testing and commissioning of following capacity auto transfer switch ATys M 3s C30 with enclosure, bus bars and all accessories required for complete operation as per the drawing. The ATS should be double break contact system for high short time withstand. ATS shall be with UV/OV, Phase sequence, Single phasing and frequency protections;630A 4P ATS

2

-

-

... More
Supply, erection, testing and commissioning of following capacity auto transfer switch with enclosure, bus bars and all accessories required for complete operation as per the drawing. The ATS should be double break contact system for high short time withstand. ATS shall be with UV/OV, Phase sequence, Single phasing and frequency protections.400A 4P ATS

6

-

-

... More
Supply, erection, testing and commissioning of following capacity auto transfer switch with enclosure, bus bars and all accessories required for complete operation as per the drawing. The ATS should be double break contact system for high short time withstand. ATS shall be with UV/OV, Phase sequence, Single phasing and frequency protections. ;200A 4P ATS

1

-

-

... More
Subhead : CABLES & TERMINATION

-

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. ;3.5cx400sq.mm Al Cable

2134

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx300sq.mm Al Cable

44

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. ;3.5cx240sq.mm Al Cable

2740

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date3.5cx185sq.mm Al Cable

1320

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. ;3.5cx150sq.mm Al Cable

545

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date.3.5cx120sq.mm Al Cable

88

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. ;3.5cx95sq.mm Al Cable

700

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date.;3.5cx70sq.mm Al Cable

1980

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. ;3.5cx50sq.mm Al Cable

1072

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date.;4cx35sq.mm Al Cable

528

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date.4cx25sq.mm Al Cable

2525

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 4cx16sq.mm Al Cable

7710

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. ;4cx10sq.mm Al Cable

14778

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date.3cx10sq.mm CU Cable

280

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date.3cx04sq.mm CU Cable

150

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date.;3cx2.5sq.mm CU Cable

100

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date.4cx16sq.mm CU Cable

150

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date.4cx10sq.mm CU Cable

958

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 4C x 2.5sq.mm Cu Control Cable

450

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 2C x 1.5sq.mm Cu Control Cable

150

-

-

... More
Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc. as required and instructed by engineer in charge.1C x 95sq.mm Copper Flexible Cable

2650

-

-

... More
Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc. as required and instructed by engineer in charge;1C x 70sq.mm Copper Flexible Cable

440

-

-

... More
Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc. as required and instructed by engineer in charge.1C x 50sq.mm Copper Flexible Cable

1550

-

-

... More
Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc. as required and instructed by engineer in charge.;1C x 35sq.mm Copper Flexible Cable

150

-

-

... More
Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc. as required and instructed by engineer in charge.;1C x 25sq.mm Copper Flexible Cable

1330

-

-

... More
Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc. as required and instructed by engineer in charge.1C x 16sq.mm Copper Flexible Cable

600

-

-

... More
Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc. as required and instructed by engineer in charge.1C x 10sq.mm Copper Flexible Cable

180

-

-

... More
Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc. as required and instructed by engineer in charge.<br>1C x 06sq.mm Copper Flexible Cable

150

-

-

... More
Supply drawings and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages etc. as required and instructed by engineer in charge.;1C x 04sq.mm Copper Flexible Cable

300

-

-

... More
Supply of following 11kV (E) grade XLPE insulated PVC sheathed armoured aluminium conductor HT power cable, insulation screened with extruded semi conducting compound in combination with copper tape suitable for 11kV earthed system confirming to relavent standard.: ;3cx300sq.mm XLPE Cable

1800

-

-

... More
Supply &laying of DWC pipe in ground level excluding excavation 110/94 mm or nearest size.

1500

-

-

... More
Subhead : END TERMINATION

-

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

6

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

4

-

-

... More
10.6.4 : Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

6

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

84

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

4

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

54

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

22

-

-

... More
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

8

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

2

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

14

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

34

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

24

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

16

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

68

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

124

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

510

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

14

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.2C X 1.5 sq. mm

12

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 4C X 1.5 sq. mm

16

-

-

... More
upplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 4C X 16 sq. mm (28mm)

6

-

-

... More
Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 4C X 10 sq. mm (25mm)

24

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required.;3C X 04 sq.mm

20

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 3C X 2.5 sq.

16

-

-

... More
90.12.24.10 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.

84

-

-

... More
90.12.24.9 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.

4

-

-

... More
90.12.24.8 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.

64

-

-

... More
90.12.24.7 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.

16

-

-

... More
90.12.24.6 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.

56

-

-

... More
90.12.24.5 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.

6

-

-

... More
90.12.24.4 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.

24

-

-

... More
90.12.24.3 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.

8

-

-

... More
90.12.24.2 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.

12

-

-

... More
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm

3750

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

750

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

142

-

-

... More
7.1.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

120

-

-

... More
7.2.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm

180

-

-

... More
7.6.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm

450

-

-

... More
7.6.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm

190

-

-

... More
7.6.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm

111

-

-

... More
7.6.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm

550

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

23579

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

2812

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

1700

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

4068

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate withinscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixingthe same in ground as required.

200

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

600

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

200

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

400

-

-

... More
8.2.2 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etcAbove 120 sq. mm and upto 400 sq. mm

600

-

-

... More
14.4 : Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.

400

-

-

... More
14.3 : Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres.

150

-

-

... More
14.5 : Deduct for not consolidation by ramming and watering while re-filling with sand and or good soil in cable/ pipe laying.

150

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia

30

-

-

... More
14.15.4 : Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal)

120

-

-

... More
Subhead : POINT WIRING

-

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

45

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

3960

-

-

... More
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

43962

-

-

... More
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm

73800

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

31104

-

-

... More
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm

1800

-

-

... More
1.22.2 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.100 mm X 100 mm X 60 mm deep

45

-

-

... More
1.22.15 : Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.250 mm X 300 mm X 60 mm deep

30

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

400

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

180

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

400

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

180

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

350

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

180

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

165

-

-

... More
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

200

-

-

... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

190

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).

1790

-

-

... More
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

1637

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.

710

-

-

... More
Supply and Fixing the following modular switches &accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) ;Step Fan regulator - type 2 M

150

-

-

... More
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

2982

-

-

... More
1.57 : Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. lCD

20

-

-

... More
Subhead : DISTRIBUTION BOARDS

-

-

-

... More
90.11.1.16 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

10

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

25

-

-

... More
90.11.1.13 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

4

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

44

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

62

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

53

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

7

-

-

... More
2.3.1 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door

1

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

36

-

-

... More
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

44

-

-

... More
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

62

-

-

... More
2.24.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB

53

-

-

... More
2.23.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 8 way, Double door SPN MCBDB

7

-

-

... More
2.23.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 6 way, Double door SPN MCBDB

1

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

15

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

14

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. <br>32 amps

7

-

-

... More
Supplying and fixing following rating 25A, FP, 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

43

-

-

... More
Supplying and fixing following rating 32A, FP, 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Supplying and fixing following rating 25A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

6

-

-

... More
Supplying and fixing following rating 32A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

73

-

-

... More
Supplying and fixing following rating 40A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

3

-

-

... More
Supplying and fixing following rating 63A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

37

-

-

... More
Supplying and fixing following rating 25A, DP, 240 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete wih connections, testing and commissioning etc. as required.

5

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1959

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, ""D"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;Single pole

1044

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

2

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

148

-

-

... More
Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ;Triple pole

12

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

737

-

-

... More
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required

150

-

-

... More
15.4.3 : Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required3 output (1output per phase) and suitable for three phase supply

1

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in MS Enclosure complete with connections, testing and commissioning etc. as required. 100 amps FP Isolator

3

-

-

... More
Supplying and fixing following rating, TPN, 415 volts, MCCB in MS Enclosure complete with connections, testing and commissioning etc. as required. ;125 amps TPN MCCB

3

-

-

... More
Supplying and fixing following rating, TPN, 415 volts, MCCB in MS Enclosure complete with connections, testing and commissioning etc. as required. ;160 amps TPN MCCB

6

-

-

... More
Supplying and fixing following rating, TPN, 415 volts, MCCB in MS Enclosure complete with connections, testing and commissioning etc. as required. 200 amps TPN MCCB

7

-

-

... More
Supplying and fixing following rating, TPN, 415 volts, MCCB in MS Enclosure complete with connections, testing and commissioning etc. as required. 250 amps TPN MCCB;

2

-

-

... More
Subhead : CONDUITS & CABLE TRAYS

-

-

-

... More
1.20.1 : Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.20 mm

1450

-

-

... More
1.20.2 : Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm

900

-

-

... More
1.20.3 : Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.32 mm

380

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

90000

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

75000

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

3500

-

-

... More
Supplying and installing perforated Hot Dipped Galvanised Perforated cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, Rate is inclusive of factory fabricated Tee's, Reducer, Bends etc. as required.300 mm width X 50 mm depth X 1.6 mm thickness

2170

-

-

... More
Supplying and installing perforated Hot Dipped Galvanised Perforated cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, Rate is inclusive of factory fabricated Tee's, Reducer, Bends etc. as required.450 mm width X 50 mm depth X 2.0 mm thickness

1405

-

-

... More
Supplying and installing perforated Hot Dipped Galvanised Perforated cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, Rate is inclusive of factory fabricated Tee's, Reducer, Bends etc. as required.<br>600 mm width X 50 mm depth X 2.0 mm thickness

410

-

-

... More
Providing and fixing the following 14 SWG Hot Dip Galvanised Ladder tray (Bolted/Fabricated) along with necessary GI suspenders (not more than 1000 MM long) at equal intervals of 900 mm as directed. Including providing cost of GI supports, nuts, bolts, washers and dash fasteners as required. The installation shall be complete in all respects (All accessories like tees, bends vertical / horizontal shall be factory fabricated and cost of these to be included in the rate).;450 mm width X 50 mm depth X 2.0 mm thickness

1280

-

-

... More
Providing and fixing the following 14 SWG Hot Dip Galvanised Ladder tray (Bolted/Fabricated) along with necessary GI suspenders (not more than 1000 MM long) at equal intervals of 900 mm as directed. Including providing cost of GI supports, nuts, bolts, washers and dash fasteners as required. The installation shall be complete in all respects (All accessories like tees, bends vertical / horizontal shall be factory fabricated and cost of these to be included in the rate.<br>600 mm width X 50 mm depth X 2.0 mm thickness

520

-

-

... More
Providing and fixing the following 14 SWG Hot Dip Galvanised Ladder tray (Bolted/Fabricated) along with necessary GI suspenders (not more than 1000 MM long) at equal intervals of 900 mm as directed. Including providing cost of GI supports, nuts, bolts, washers and dash fasteners as required. The installation shall be complete in all respects (All accessories like tees, bends vertical / horizontal shall be factory fabricated and cost of these to be included in the rate.;900 mm width X 75 mm depth X 2.0 mm thickness

260

-

-

... More
Providing and fixing the following 14 SWG Hot Dip Galvanised Ladder tray (Bolted/Fabricated) along with necessary GI suspenders (not more than 1000 MM long) at equal intervals of 900 mm as directed. Including providing cost of GI supports, nuts, bolts, washers and dash fasteners as required. The installation shall be complete in all respects (All accessories like tees, bends vertical / horizontal shall be factory fabricated and cost of these to be included in the rate;1200 mm width X 75 mm depth X 2.0 mm thickness

215

-

-

... More
Supplying and installing Hot Dipped Galvanised Cable Tray Cover (galvanisation thickness not less than 50 microns), in convenient sections, joined with connectors, GI Nuts, Bolts etc….. as required.;Cover for 600 mm width X 50 mm depth X 2.0 mm thickness

150

-

-

... More
Supplying and installing Hot Dipped Galvanised Cable Tray Cover (galvanisation thickness not less than 50 microns), in convenient sections, joined with connectors, GI Nuts, Bolts etc….. as required.;Cover for 450 mm width X 50 mm depth X 2.0 mm thickness

400

-

-

... More
Supplying and installing Hot Dipped Galvanised Cable Tray Cover (galvanisation thickness not less than 50 microns), in convenient sections, joined with connectors, GI Nuts, Bolts etc….. as required.Cover for 300 mm width X 50 mm depth X 2.0 mm thickness

800

-

-

... More
Supplying and installing of Pre Galvanised Raceway with Cover, in convenient sections, joined with connectors, Rate inclusive of GI Suspenders & Supports, GI Nuts, Bolts etc….. as required.300mm width X 50 mm depth X 1.6 mm thickness for Raceways and 1.6mm for Cover;

530

-

-

... More
Supplying and installing of Pre Galvanised Raceway with Cover, in convenient sections, joined with connectors, Rate inclusive of GI Suspenders &Supports, GI Nuts, Bolts etc….. as required.450mm width X 50 mm depth X 2.0 mm thickness for Raceways and 1.6mm for Cover

90

-

-

... More
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories like cable divider, angles, couplers, cross, end caps etc.... conforming to IEC 61084/ BS 476; 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.

200

-

-

... More
Subhead : LIGHT FIXTURES

-

-

-

... More
SITC of recess mounted 2x2 24W(+/- 10% Tolerance) LED luminaire of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 110 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Philips- RC380B LED30S-5700 G5 L60W60 PSU OD, Wipro-CRCO10R024HP57HE;Note: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

2572

-

-

... More
SITC of recess mounted 2x2 , 31W(+/- 10% Tolerance) LED luminaire of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor 0.9,THD;10%, rated life of 50,000 hours, system efficacy greater than or equal to 110 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Philips- RC380B LED36S-5700 G5 L60W60 PSU OD, Wipro-CRCO10R030HP57HENote: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects

356

-

-

... More
SITC of recess mounted 33W(+/- 10% Tolerance) LED luminaire of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- RC740B LED30S/857 W60L60 PSU W, Wipro- LM29-451-XXX-57-XX&lNote: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

30

-

-

... More
SITC of recess mounted LED Cleanroom fitting 40W 2x2' ,(+/- 10% Tolerance) of CRCA powder coated housing, driver with minimum 4KV Surge protection, power factor 0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 80 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. Makes: Philips-CR652B LED33S CR CW CA, Wipro LC20-551-XXX-57-XX Recess mounted;Note: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

111

-

-

... More
SITC of recess mounted Downlights of 6W(+/- 10% Tolerance) LED luminaire of Die Cast Aluminium Housing, driver with minimum 4KV Surge protection, power factor ;0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture.. Makes: Philips- DN295B LED6S-6500 PSU WH, Wipro- CRDL11R008HP57;Note: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

775

-

-

... More
;SITC of recess mounted Downlights of 18W(+/- 10% Tolerance) LED luminaire of Die Cast Aluminium Housing, driver with minimum 4KV Surge protection, power factor ;0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. . Makes: Philips- DN194B LED16S-6500 PSU WH S2, Wipro- CRDL11R023HP57;Note: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

1633

-

-

... More
SITC of Surface mounted Downlights of 15W(+/- 10% Tolerance) LED luminaire of driver with minimum 4KV Surge protection, power factor ;0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- SM250C LED16S- 6500 PSU WH, Wipro- LD81-131-XXX-60-SMNote: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

193

-

-

... More
SITC of LED TubeLights of 20W(+/- 10% Tolerance) with Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor0.9,THD;10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- BN308C LED20S-6500 L120 PSU WH, Wipro- LL24-251-XXX-57-XX;Note: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.;

549

-

-

... More
SITC of LED TubeLights of 40W(+/- 10% Tolerance) with Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor0.9,THD10%, rated life of 50,000 hours, system efficacy greater than or equal to 90 lm, with a CRI of 80 or above, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridgelux, USA / Lumiled USA / Citizen Japan / Osram should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips- BN308C LED40S-6500 L120 PSU WH, Wipro- LL24-541-XXX-57-XXNote: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

113

-

-

... More
SITC of LED Mirror Lights of 5W(+/- 10% Tolerance) with polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor 0.9,THD;10%, system efficacy greater than or equal to 80 lm, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips, WiproNote: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

251

-

-

... More
SITC of Bulkhead of 10W(+/- 10% Tolerance) with polycarbonate diffuser having driver of minimum 4KV Surge protection, power factor 0.9,THD10%, system efficacy greater than or equal to 80 lm, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. (Test Reports for the above credentials shall be submitted and minimum 5 Year Warranty for the fixture should be provided by the contractor). Makes: Philips, Wipro;Note: Light fixtures complete with all necessary accessories including PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

145

-

-

... More
Fan Fixture:SITC of Ceiling fan of 1200mm sweep,energy efficient,five star rated BLDC motor high speed.PF above 0.95, including down rod of standard length (upto 30cm)

150

-

-

... More
Supply Installation Testing & commissioning of 400mm Sweep Wall fan including all the accessories as required.

30

-

-

... More
Subhead : EXTERNAL LIGHTING

-

-

-

... More
90.15.2.3 : Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters

2

-

-

... More
90.15.3.8 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 8 Meters

18

-

-

... More
90.15.3.7 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 8 Meters

50

-

-

... More
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

100

-

-

... More
90.15.4.9 : Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

12

-

-

... More
SITC of 8W (+/-10% tolerance) IP/=65, Bollard LED luminaire having/= 500 lm system output (Luminaire lumen output) for landscape lighting. ANSI rated LEDs from reputed makes should be provided. Luminaire efficacy should be greater than or equal to 70 lumens/watt and with minimum 4 KV surge protection. Catalogue Number : Wipro , Philips. ;Note: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.

90

-

-

... More
Subhead : EARTHING

-

-

-

... More
Supply and installation of Plate Earthing with 1200mmx1200mmx12mm CI plate (conforming to IS:3043-1987) complete with RCC inspection chamber of size 1000x600x500mm with RCC cover, GI class B pipe of 50 mm dia extending upto middle of the plate and clamping to the plate with GI clamps and bolts, funnel having 20G GI wire mesh, identification of earth pit with yellow paint below the chamber cover, mixtures of charcoal around electrode including digging of pit up to permanent moisture level but not less than 3 metre depth and back filling. (value of earth resistance should be less than 1 ohm ).

14

-

-

... More
Supply of UL Listed &CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250 micron tested as per IEC 62561-2 & is provided with universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided with Heavy duty earth chamber with dimension of 300mmx 300mmx 450mm of 5000kg load bearing capacity to ensure the safety of earthing system including all accesories as required for complete installation as instructed by engineer in charge.

24

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant.;50x10 Cu strips tinned at the point of contact.

580

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultan;32x6 Cu strips tinned at the point of contact.

20

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultantt25x6 Cu strips tinned at the point of contact.

30

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant.;25x3 Cu strips tinned at the point of contact.

200

-

-

... More
Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant. 50x10 Cu strips tinned at the point of contact.

320

-

-

... More
Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.;25x6 Cu strips tinned at the point of contact.

45

-

-

... More
Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.;25x3 Cu strips tinned at the point of contact

5300

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

5400

-

-

... More
Subhead : LIGHTNING PROTECTION SYSTEMS

-

-

-

... More
3 meter air terminal with acessories&;Providing and fixing Air terminals as per IEC -62305 part-3 and IS 2309 16mm rod tapered to 10 mm aluminum rod 3 meter rod:Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) 101 VL 3000: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. System consist of Fang Fix with base and clamp on the top air terminal is erected.Fang fix clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform. 2 nos of 16 KG stone of 365 mm diameter, high level of stability. Quick and easy mounting of interception rod using anchors. Concrete, frost-resistant, can be stacked

18

-

-

... More
;8mm solid aluminum round conductor:supply and providing 8mm solid aluminium round conductor, meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area.Polyamide Conductor holder with holding base for parapet/Flat roof:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance.;a) Vertical run- Down conductor

1400

-

-

... More
8mm solid aluminum round conductor:supply and providing 8mm solid aluminium round conductor, meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IEC 62305) RD 8/ALU: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) With 50 sq.mm cross sectional area. Polyamide Conductor holder with holding base for parapet/Flat roof:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance."b) Horizontal run-Parapet application

1850

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt spring washer spaced at 50mm)

450

-

-

... More
Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate.

60

-

-

... More
Providing and fixing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts .

95

-

-

... More
Providing and fxing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Connectors: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece).

57

-

-

... More
Providing and fixing of Equipotential bonding rail for outdoor use.

27

-

-

... More
Providing and fixing of test joint suitable for 10mm dia copper coated solid steel round conductor with 100 microns of copper bonding (if pure copper conductor 25x3 mm solid tape also can be used) and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm.

27

-

-

... More
Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric.

27

-

-

... More
SITC of CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 20mm with copper coating thickness of 250micron tested as per IEC 62561-2 & is provided with universal clamp made of SS to connect rod with flat conductor. Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. The above arrangements shall be provided with Heavy duty earth chamber of dimension 300mmx 300mmx 170mm with 5000kg load bearing capacity to ensure the safety of earthing system.

27

-

-

... More
Subhead : MISCELLANEOUS WORKS

-

-

-

... More
Supply and providing 6 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 5429/1969.

150

-

-

... More
Supply and providing First Aid Box.

2

-

-

... More
Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision

2

-

-

... More
Supply &fixing Approved Electrical Scheme/ Layouts printed in 6mm thick Transperent Acrylic sheet fixed with suitable SS Studs in walls as directed by Engineer in charge.

12

-

-

... More
Supply and providing 6mm Thick MS chequered plate including cutting, welding, painting etc. as required for cable duct covering etc.

180

-

-

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters ;FIRE in black and gold. Cost shall be inclusive of providing MS stand for 2 nos of fire buckes, or , duly painted over a coat of primer.

2

-

-

... More
Supply of 1 pair 11 KV rubber hand gloves of approved make.

2

-

-

... More
Supply and providing 12 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 11 kV dielectric strength conforming to IS 5429/1969

80

-

-

... More
EXTRA LOW VOLTAGE SYSTEM - Subhead : Networking

-

-

-

... More
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable

82595

-

-

... More
Supplying and drawn of UTP 4 pair CAT-6A LAN cable in the existing surface/recessed steel/PVC conduit as required - 1 run of Cable

7800

-

-

... More
Supplying, fixing testing &commissioning of CAT-6 information oultets and accessories on wall surface/recess etc complete as required.

1203

-

-

... More
Supplying, fixing testing &commissioning of CAT-6A information oultets and accessories on wall surface/recess etc complete as required.

120

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)

1203

-

-

... More
Supplying and fixing of CAT-6 24 port Front Managable Straight Loaded Patch panels

84

-

-

... More
Supplying and fixing of CAT-6A 24 port Front Managable Straight Loaded Patch panels

8

-

-

... More
Supplying and fixing of Front Managable Straight Loaded Telephone Patch panels

24

-

-

... More
Providing and fixing 3 feet long CAT-6 UTP Patch Cords

1400

-

-

... More
Providing and fixing 3 feet long CAT-6A UTP Patch Cords

120

-

-

... More
SITC of 42U Wall Mount Rack with power distribution unit, cable managers, fans and other accessories.

2

-

-

... More
SITC of 24U Wall/floor Mount Rack with power distribution unit, cable managers, fans and other accessories.

8

-

-

... More
SITC of 15U Wall Mount Rack with power distribution unit, cable managers, fans and other accessories.

23

-

-

... More
SITC of 06U Wall Mount Rack with power distribution unit, cable managers, fans and other accessories.

4

-

-

... More
Supply, installation and testing commissioning of Fully Managed 24 Port CAT 6 Network Switch with minimum of 2 SFP Uplink

44

-

-

... More
Supply, installation and testing commissioning of Fully Managed 12 Port CAT 6 Network Switch with minimum of 2 SFP Uplink

6

-

-

... More
Supply, installation and testing commissioning of Fully Managed 24 Port 10GBASE CAT 6A stackable Network Switch with minimum of 2x10G SFP Uplink

7

-

-

... More
Supply Installation Testing & Commissioning of Managed 24 Port Giga PoE intelligent Ethernet Switch with 370Watt PoE Power at 24 x 10/100/1000 Base-T PoE Fast Ethernet ports and with min 2SFP Giga Ports (provision for Fiber Giga connectivity)

11

-

-

... More
Supply Installation Testing & Commissioning of Managed 12 Port Giga PoE Intelligent Ethernet Switch with minimum of 124Watt PoE Power at 12 x 10/100/1000 Base-T PoE Fast Ethernet ports and with min 2SFP Giga Ports (provision for Fiber Giga connectivity)

24

-

-

... More
SITC 10G SFP Module for Access Switches

7

-

-

... More
SITC 1G SFP Module for Access Switches

85

-

-

... More
SITC of POE Based Wireless-N Access Point

12

-

-

... More
Supply & Laying of 12 core unarmoured Multimode Optical Fibre Cable.

4800

-

-

... More
Supply fixing splicing Termination & commissioning of 12 Port Fully loaded LIU Rack mountable (with Pigtail) including all the accessories like, LC duplex for 6mm fibre cassette for pigtails, blanking plate for modular drawer etc... as required for the proper functioning of the system.

33

-

-

... More
Supply fixing splicing Termination & commissioning of High Density 480 Core Fully loaded LIU Rack mountable (with Pigtail) including all the accessories like, LC duplex for 6mm fibre cassette for pigtails, blanking plate for modular drawer etc... as required for the proper functioning of the system.

1

-

-

... More
SITC of LC-LC Patch Cord

92

-

-

... More
Subhead : Telephone system

-

-

-

... More
Supply, installation, testing & commissioning of IP PBX Equipped with below configuration. • 340 Analogue extension expandable up 400. • 2 PRI interface • 4 port welcome message and Auto Attendant up 4 level • Voice mail box 250 (8 port 200hours capability) • Minimum 30 Nos IP/SIP Extension number • Operator console (24 key KTS +DSS) • 01 PC biased operator console

1

-

-

... More
SITC of 10 Pair (0.5mm) Armoured Telephone cable

1705

-

-

... More
SITC of 20 Pair (0.5mm) Armoured Telephone cable

2630

-

-

... More
SITC of 50 Pair (0.5mm) Armoured Telephone cable

420

-

-

... More
SITC of IP Telephone

30

-

-

... More
SITC of Analogue Telephone

150

-

-

... More
SITC of 20Pair Krone Box

7

-

-

... More
SITC of 40 Pair Krone Box

1

-

-

... More
Subhead : CCTV

-

-

-

... More
Camera - Bullet - Supply, Installation,testing and commissioning of Varifocal Bullet Camera with 2 MP, H.264 / H.265, built-in IR LED, 2.8/3.6 mm to 9/12 mm, 20 to 30 meters IR range, IP 66 with all connectors and necessary accessories for mounting in false ceiling/True Ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet)

51

-

-

... More
Camera for Corridor - Dome - Supply, Installation, testing and commissioning of IP based 2.8/3.6 mm to 9/12 mm verifocal lens, 2MP resolution, H.264 / H.265, 1/2.8" Progressive Scan CMOS Day/Night, IR dome POE enabled camera, 20 to 30 meters IR range, 120 dB digital WDR with all connectors and necessary accessories for mounting in false ceiling as required for complete installation as directed by Engineer in charge. PoE (Power over Ethernet)

145

-

-

... More
Supply, Installation, Testing Commissioning of Storage and Video management Software (Detailed Technical Specification Attached)

2

-

-

... More
Supply, installation, Testing and Commissioing of 40'' Flat Screen HD Professional LFD(24X7) with Interfaces include HDMI, DVI, D-sub, Component and Composite input as well as RS-232C and RJ45 for extensive connectivity, remote control and wall mount unit / floor stand complete with making connections etc complete as reqd.

2

-

-

... More
Supply, Installation, Testing Commissioning of Workstation (Detailed Technical Specification Attached)

1

-

-

... More
Subhead : Access Control System

-

-

-

... More
Supply Installation Testing and Comissioning of 4 reader controller with Built in Web server , Upgradeable firmware flash; Having communication options of RS232,RS484& Ethernet; Built in PCI interface , Support Anti Pass back(Global & Local) , Support 128 unique card format & 8 site code, up to 75 bit card format for security purpose. Given controller should also support 127 Time zone ,128 Access levels & 255 holidays. • Four-reader controller • Built-In Linux Web server • Flash upgradeable firmware • Multiple communication options • RS232, RS485, Ethernet • Built-In PCI interface • Anti-pass back (APB) control • UL294 listing/CE Certification

24

-

-

... More
Supply Installation Testing and Comissioning of Multi Class Card Reader, Secure Identity Object™ (SIO) on iCLASS Seos, iCLASS SE/SR, MIFARE DESFire EV1 and MIFARE Classic Standard iCLASS Access Control Application ISO14443A (MIFARE, DESFire, NFC) CSN, UL294/cUL, FCC Certification, CE, ROHS ,OPERATING TEMPERATURE -31°F to 150°F (-35°C to 65°C); BLE: -15° to 150°F (-25° to 65°C) OPERATING HUMIDITY 5 to 95% relative humidity (non-condensing) OPERATING VOLTAGE RANGE 5 — 16 VDC, PANEL INTERFACES Wiegand IP RATING IP55

94

-

-

... More
Supply, installation, testing and commissioning of Multiclass Class Contactless Smart Card, 8KB Memory, Composite card body with Lanyard to hold the cards as per specification.

120

-

-

... More
Supply, Installation, Testing and Commssioining of EMERGENCY BREAK GLASS UNIT with accessories

47

-

-

... More
Supply, Installation, Testing and Commssioining of Electromagnetic Lock with required mounting brackets for single door

11

-

-

... More
Supply, Installation, Testing and Commssioining of Electromagnetic Lock with required mounting brackets for double door

36

-

-

... More
Supply, Installation, Testing and Commssioining of Access Control Software & Time Attendance Software :- i)Multi User supports Basic Time & Attendance, anti passback features. ii) All standard access control, audit trails, time & attendance feature, alarm reports, atleast 2 Lac user handing capacity iii) Access Control software license suitable for total number of card reader indicated above with a provision of 30 % spare and future expansion capacity. Software license not to be restricted to number of readers and users

1

-

-

... More
Supply Laying Installation commissioning of Shielded 2 Core 1.0 Sq.mm unarmoured copper cable

4700

-

-

... More
Supply Laying Installation commissioning of Shielded 6 Core 1.0 Sq.mm unarmoured copper cable

4700

-

-

... More
FIRE PROTECTION AND LIFE SAFETY SYSTEM - Subhead : PUMPS, PANELS AND ACCESSORIES

-

-

-

... More
MAIN PUMP - ELECTRICAL MAIN PUMP - Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Hydrant Pump Set: Electrical Driven, Capacity: 2280 LPM at 100 Meter Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, High Efficient IE-3 rated, Squirrel Cage Induction Electric Motor, Suitable HP, 3Ph, 50 Hz, suitable RPM as per manufacturer reccomendation, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

1

-

-

... More
SPRINKLER PUMP - ELECTRICAL Supply, installation, testing and commissioning of Horizontal long coupled End Suction Fire Sprinkler Pump Set: Electrical Driven, Capacity: 2280 LPM at 100 Meter Head, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, High Efficient IE-3 rated, Squirrel Cage Induction Electric Motor, Suitable HP, 3Ph, 50 Hz, suitable RPM as per manufacturer reccomendation, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions

1

-

-

... More
DIESEL PUMP: Supply, installation, testing and commissioning of Stand By / Back Up Fire Pump, Horizontal long oupled, End Suction Pump, Engine Driven, suitable for Automatic operation and consisting of the following and complete in all respect as required; Capacity: 2280 LPM at 100 Meter Head conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, coupled to High efficient Radiator Cooled Diesel Engine, Suitable HP, suitable RPM as per manufacturer eccomendation, and with Control Panel with Auto Starting Facility, by activation of concerned pressure Switch and thro. 12V/24 V Electric Starter, Battery of adequate rating and with Battery Charger, Battery Leads, Diesel Tank for 6 hrs operation, exhaust pipe extended up to 1 mtr outside pump house, duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, complete with necessary civil foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, and all other necessary fixing accessories, all as per Technical Specifications.

1

-

-

... More
EXHAUST PIPES: Supplying and fixing exhaust gas piping of suitable dia matching the Diesel Fire pump, welded black M.S 'B' class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh & aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be nstalled with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to engine and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.

60

-

-

... More
JOCKEY PUMP: Supply, installation, testing and commissioning of Jockey Pump: Electrical Driven, Capacity: 180 LPM at 105 Mtrs. Head, Vertical Multi Stage Inline Pump with S.S Impeller, Mechanical Seal, and with High Efficient IE-3 Rated Squirrel Gauge Induction Motor, Suitable HP, 3Ph, 50 Hz, suitable RPM as per manufacturer recceomndation, TEFC, complete with necessary concrete foundation duly plastered, MS fabricated common base plate with foundation bolts, compound gauge, water recirculation arrangement, pressure relief valve, anti-vibration mounts, as per requirement and nececssary earthing of Electric Motors, etc. all as per the Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

2

-

-

... More
MOTOR CONTROL PANEL - Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated Common Control Panels for Main Fire Pumps & Jockey Pumps, made out of 16 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates (top entry) made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. The panel shall be IP: 54 protection,complete with Main Isolator, Bus Bar Chamber, Volt Meter, Ammeter, Individual Star- Dealt Starters for Main Pumps, DOL Starter for Jockey Pump, Contactors, Auxiliary Contacts, Timers for automatic operation and to avoid freequent re-starts, Indicating Lamps, Fuses, Auto / Manual Selector Switches for all Fire Pumps, Manual On / Off Buttons for Jockey Pump & Manual On Buttons for Main Pumps, all internal wiring etc. The price for Control Panel shall be inclusive of, Control Cabling, in Steel Conduits, for automatic starting of Main Pumps & Automatic start and stop for Jockey Pump and Earthing of the Panel, all as per Technical Specifications, Schematic Drawing, Prevailing Rules, Standards, Requirement and Site Conditions. The Panel shall be to the approval of Kerala State Electrical Inspectorate. Incomer - 630A, FP, MCCB Isolator - 1No. 630A, 415V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. brMulti function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAhbrClass B + C / Class 1 + 2 Surge arrestor device with necessary MCCB for protection of same - 1 Set. RYB phase indicating LED lamps with control fuses and switches - 1 set Outgoingbr250A, TP+NL, MCCB Isolator + Star delta starter with all accessories Without overload relays / protection - 2 Set.br25-63A, TP+NL, MCCB Isolator + DOL Starter with all accessories with overload realy and single phase preventor - 2 Set. Supply, Installation, Testing & Commissioning

1

-

-

... More
Supply and Laying of below sized XLPE insulated PVC sheathed Aluminium conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3.5C x 185 sq mm

60

-

-

... More
Supply and Laying of below sized XLPE insulated PVC sheathed Aluminium conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections. 3C x 10 sq mm

60

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 185 sq. mm (57mm)

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 10 sq. mm (22mm)

4

-

-

... More
AIR CUSHION VESSEL Supplying, Installation, Testing & Commissioning of air cushion tank (air vessel) of continuous welded construction, fabricated out of atleast 8mm thick steel with dished ends, and supporting legs, Capable of carrying 15Bar Pressure, 250mm dia & 1200mm high complete with necessary air release valve, safety valve, pressure gauge, flange connection to the wet riser piping with necessary piping to meet the functional requirement of the system.

1

-

-

... More
AIR RELEASE VALVE Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including necessary accessories and connections.

22

-

-

... More
PRESSURE GAUGE: Supply installation testing and commissioning of 4"" dia. Pressure Gauge, with ISI Mark or of equivalent International Standards.Weather / Water Proof, Type with gunmetal /brass shut off cock.

4

-

-

... More
PRESSURE SWITCH Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC etc. complete as required

5

-

-

... More
ALARM CHECK VALVE Supply, installation, testing and commissioning of Alarm check valve with CI Body and Clapper, torsion Spring & Nut of Stainless Steel for 6" (150mm Dia) featured with grooved seat alarm port, external by pass, and vertically installed Alarm Check Valve having Working pressure of 175psig, Flow Rate of 3000lit/min, UL Certified, should have the following accessories like Pressure gauages, Pressure Operated switches, Drain Valve, Alarm Test Units, water motor gong, retard chamber inclusive

1

-

-

... More
Supply and providing 3mm Thick MS chequered plate including cutting, welding, painting etc. as required for shaft covering.

15

-

-

... More
Subhead : FIRE PIPES, VALVES AND ACCESSORIES

-

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 250 mm Dia

26

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 200 mm Dia

45

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 150 mm Dia

2360

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 100 mm Dia

1273

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 80 mm Dia

1195

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 65 mm Dia

1285

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 50 mm Dia

2203

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 40 mm Dia

1475

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 32 mm Dia

2520

-

-

... More
Hydrant, Sprinkler System Plant Room : Providing, fixing, pressure testing and commissioning of Above Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I. The pipe with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50 mm diameter. The pipe with Galvanized Grooved Fittings for pipes above 50mm diameter. The pipe with But Welded fittings for pump room for all sizes. Piping shall be with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification. 25 mm Dia

4566

-

-

... More
Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, Gear Operated type, confirming to BS:5155 /ASTM A-536, grade 65-45-12, with Supervisory / Tamper Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. 200 mm Dia

2

-

-

... More
Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, Gear Operated type, confirming to BS:5155 /ASTM A-536, grade 65-45-12, with Supervisory / Tamper Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. 150 mm Dia

78

-

-

... More
Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, Gear Operated type, confirming to BS:5155 /ASTM A-536, grade 65-45-12, with Supervisory / Tamper Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. 100 mm Dia

22

-

-

... More
Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, Gear Operated type, confirming to BS:5155 /ASTM A-536, grade 65-45-12, with Supervisory / Tamper Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. 80 mm Dia

2

-

-

... More
Supply, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, Gear Operated type, confirming to BS:5155 /ASTM A-536, grade 65-45-12, with Supervisory / Tamper Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete.: 50 mm Dia

2

-

-

... More
Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. 200 mm Dia

2

-

-

... More
Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. 150 mm Dia

13

-

-

... More
Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. 100 mm Dia

2

-

-

... More
Supply, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. 80 mm Dia

2

-

-

... More
Supply, fixing, testing and commissioning of Forged Ball Valve, PN-20 gunmetal /cast alloy, including necessary accessories and connections a) 25 mm Dia

97

-

-

... More
Supply, fixing, testing and commissioning of Forged Ball Valve, PN-20 gunmetal /cast alloy, including necessary accessories and connections b) 50 mm Dia

66

-

-

... More
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8239 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer’s technical details. i. Internal lining with Cement Mortar. ii. External Coating with a layer of metallic zinc + a layer of and bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall be inclusive of earthwork escavation and providing Masonary / PCC / RCC Thrust Blocks as per requirement. 200mm Dia

100

-

-

... More
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8239 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer’s technical details. i. Internal lining with Cement Mortar. ii. External Coating with a layer of metallic zinc + a layer of and bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall be inclusive of earthwork escavation and providing Masonary / PCC / RCC Thrust Blocks as per requirement. 150 mm Dia

768

-

-

... More
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8239 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer’s technical details. i. Internal lining with Cement Mortar. ii. External Coating with a layer of metallic zinc + a layer of and bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall be inclusive of earthwork escavation and providing Masonary / PCC / RCC Thrust Blocks as per requirement. 100 mm Dia

55

-

-

... More
Providing, fixing, pressure testing and commissioning of Under Ground Fire Hydrant Pipe Work with Ductile Iron Pipes conforming to IS: 8239 / BIS EN: 545, Working Pressure 16 Bar (Class K-9), with Socket and Spigot. Pipe Fitting shall of Class K12. All the Pipes and Fittings shall with following protective coats / lining as per Standards and Manufacturer’s technical details. i. Internal lining with Cement Mortar. ii. External Coating with a layer of metallic zinc + a layer of and bitumen coating. iii. Further protection with loose & air / water tight polythene sleeves. The cost for underground pipe work shall be inclusive of earthwork escavation and providing Masonary / PCC / RCC Thrust Blocks as per requirement. 80 mm Dia

55

-

-

... More
Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark, Stainless Steel-304 body with 63mm. oblique instantaneous single outlet, 75mm. N.B. flanged inlet, Stainless Steel -304 spindle, complete with PVC blank cap, G.I. chain etc.

91

-

-

... More
Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark.

91

-

-

... More
Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fiber. conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg/Cm2 and Burst Pressure 38 Kg/Cm2. The Fire Hose shall be with IS: 636 Type-A marking and 63mm. dia.x15Mtr.long with pair of 63mm. male and female instantaneous couplings, Stainless steel-304, having IS: 903 mark and duly S. S. wire wounded.

182

-

-

... More
Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided /rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm. isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set.

70

-

-

... More
Supply, installation, testing and commissioning of M.S. CRCA sheet fabricated 16 SWG Fire Hydrant hose boxes suitable for storing 2 Nos.15M hoses and 1 No. Branch pipe of 63mm dia size. Boxes will be duly painted with two coats zinc primer and finish fire red colour enamel paint outside with locking arrangement for Double leaf front glass doors having 4mm thick glass, complete as per specifications

72

-

-

... More
Supply and fix at site in position Weather Proof Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate Two 15m length of delivery hose and branch pipe, acrylic fronted double door with lock 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and pole for mounting, all as per requirement.

19

-

-

... More
Supply, installation, testing and commissioning of Fire Brigade Inlet Breeching, C.I. body, having 4 Gunmetal, 63mm. male instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 4 nos. of rubber blank caps and G.I. chains.

3

-

-

... More
Supply, installation, testing and commissioning of Fire Brigade Draw Off Outlet C.I. body, having 4 Gunmetal, 63mm. female instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 4 nos. of rubber blank caps and G.I. chains

1

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage , Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings.brPendant Type, 68 / 79 Degree C Rating

3531

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage , Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings.brPendant Type, 93 Degree C Rating

51

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage , Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings.brUpright Type, 68 Degree C Rating.

3296

-

-

... More
ROSETTE PLATE - Providing & Fixing 2 Piece Chrome Plated Friction Fit recessed escutcheon for pendant sprinklers, as per requirement.

3474

-

-

... More
Providing, Fixing, Testing and Commission Flexible Sprinkler Hose; UL Listed, FM Approved, 25mm. (1") BSP Male Inlet, 15mm. (1/2") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, length: 1500 mm, and with all connecting systems and accessories.

3474

-

-

... More
Providing, fixing, testing and commissioning of SLUICE VALVE Ductile Iron, PN-16, TYPE: RISING STEM, PROD STD: IS 14846, Body-DUCTILE IRON (ASTM A 536), SEAT: Cu-Alloy, Stem: SS.410, Ends :FLANGED AS PER IS 1538/PN 16, PRESS. RATING : BODY: 21kg/cmsq, SEAT: 16 kg/cmsq. as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. 200 mm"

2

-

-

... More
Subhead : FIRE ALARM SYSTEM

-

-

-

... More
Fire Alarm Control Panel - Supply, installation, testing and commissioning of 32 Bit Microprocessor based Multi-loop, True Peer-to-Peer Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 event plus 1000 alarm log history events, QWERTY keypad/Soft programming. The panel should be equipped with Loop Cards of adequate capacity to incorporate the devices and detectors for the project as per the manufacturer recommendation considering 20% spare capacity in each loop. The panel shall work in degrade mode to give a general alarm even in case of CPU failure. FACP shall have Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The FACP shall be provided with Modbus/Bacnet for integrating to Building Management System. All the FACPs shall be networked over RS485 or proprietary protocol with minimum network speed of 256 kbps on Copper wire communication. There shall be options in the fire alarm system to upgrade the networking to fiber optic supporting minimum 1 Mbps network speed. Software Integration of all FACP's shall be provided for Monitoring and Controlling of all FACPs in the network. Failure of any one network node (FACP, GUI, Modbus etc) shall not affect the functioning of other nodes. The complete FACP and all accessories including peripheral devices shall be UL Listed and FM approved. The FACP should be integrated with PC based Fire Graphic Station with Graphic User Interface software, alarm handling, SMS/email facility etc...."

3

-

-

... More
REPEATER PANEL: Supply, installation, testing and commissioning of active repeater panel. It shall be powered from the Main FACP & shall be supplied with necessary interface cards for connecting to FACP. The Panel shall have minimum 2 x 40 characters back lit LCD display with necessory battery backup for 48 hrs operation. The panel shall be UL listed and FM approved.

1

-

-

... More
Addressable Manual Call Point (Pull down / Break Glass Type). Addressing shall be with user friendly Rotary and dip switch/electronically addressable. The MCP shall be UL Listed and FM Approved

68

-

-

... More
SITC of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 2% obs/ft. The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall adapt to its environment by utilizing a built-in microprocessor to determine its environment and choose the appropriate sensing settings for early detection and reduction in false alarm. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal/dip switch/Electronically Addressable. The detector shall be UL Listed and FM Approved. (a) Above ceiling

1545

-

-

... More
SITC of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 2% obs/ft. The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall adapt to its environment by utilizing a built-in microprocessor to determine its environment and choose the appropriate sensing settings for early detection and reduction in false alarm. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal/dip switch/Electronically Addressable. The detector shall be UL Listed and FM Approved (b) Below ceiling

1705

-

-

... More
SITC of Addressable Rate of Rise Heat Detector rated at 9.4 deg C/min. The detector shall have LED for 360 deg viewing. Addressing shall be with user friendly Rotary and dip switch/electronically addressables.The detector shall be UL Listed and FM Approved

58

-

-

... More
SITC of Addressable Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 75cd flashintg at 1 Hz for visual indication. The sounder shall be UL Listed and FM approved.

66

-

-

... More
SITC of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal/Dip switches/Electronically Addressable. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved.

16

-

-

... More
SITC of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide DPDT contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal/DIP switches/Electronically Addressable. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved.

47

-

-

... More
SITC of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal/DIP switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved.

69

-

-

... More
SITC of Addressable Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved.

172

-

-

... More
Providing, fixing, test and commission External Power Supply Unit, 24V, 5Amps. DC, with 7Ah. Battery Back up, for sounders, sounder bases, Strobes etc, as detailed in the technical specifications.

16

-

-

... More
Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armored Cables with Red Colour, as per requirement and Technical Specifications.

55000

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with above 20 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System. The control cabling from flow switches to Fire Sprinkler Annunciating Panel shall be measured separately.

69

-

-

... More
Subhead : TALK BACK ANNOUNCING CONSOLE

-

-

-

... More
Providing, fixing, test and commission 36 Zone Simplex type talk back master control Console having zone wise selection in powder coated 16 swg CRCA sheet housing, complete with 8 to 96 zone expandable system, AC and DC meter to measure supply, push to talk facility by call/call back facilities and Mike LED display unit for location display, in built battery charger and battery space along with Amplifier, 500 W RMS Output including necessary control wires, jack ets as per specification and required.

1

-

-

... More
Providing, fixing, testing and commissioning of 6 Watt Wall Mounted type Talk Back System Speaker with Call Switch, in suitable and approved housing to approved colour /shade, all as per specification.

72

-

-

... More
Providing, fixing, laying, test and commissioning 2Core x 1.5 mm2 FRLS Armoured Cables, as per Technical Specifications.

4000

-

-

... More
Subhead : SIGNAGES

-

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (a) Fire Lift sign board (12" x 4")

30

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (b) Passenger/Fire Lift sign board (12" x 4")

112

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (c) Fire Duct sign board (12" x 4")

81

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (d) Fire Exit Light, Laser type, with High Glow LED, size: 12” x 6” Size, Ceiling Mounting type with hanging clamps, on/off switch, Red/ Green Colour option, power consumption: 18 Watt, with 2 Hr. battery backup.

40

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (e) Electrical Duct sign board (12" x 4")

45

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (f) Main Staircase sign board (12" x 4")

27

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (g) Fire Staircase sign board (12" x 4")

45

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (h) Floor Display sign board (12" x 4")

54

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (i) Fire Assembly Point (16" x 16")

1

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (j) Pump Room sign board (12" x 4")

1

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (k) Fire Control Room sign board (12" x 4")

1

-

-

... More
Subhead : FIRE EXTINGUISHER

-

-

-

... More
Supply, installation, testing & commissioning of Portable Fire Extinguisher as per BIS 2190 and IS: 15683:2018 and with relevant ISI Stamping/Marking. ABC Dry Chemical Store Pressure Type - 4 Kg.

104

-

-

... More
Supply, installation, testing & commissioning of Clean Agent Modular Type Fire Extinguisher 5Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with charge of HFC Blend A, It is a blend of Hydro Fluoro Carbon and organic detossificant essence P26. The sprinkler body will comprise of temperature sencitive quartsoid bulb of temperature rating of 68 deg C. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling. Fire Extinguisher manufatured as per BIS 2190 and IS: 15683:2018 and with relevant ISI Stamping/Marking.

45

-

-

... More
Subhead : FIRE RATED DOORS

-

-

-

... More
Providing and fixing 48mm thick fire resistant door for 120 minutes fire rating conforming to BS476 Part- 22 & IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, made out of 1.2mm thick galanized steel sheets, double skin door shell with suitable mounting on door frame, The door frames are manufactured from 1.6mm thick galvanised steel sheet (zinc coating not less than 120 gsm/m2 sandwiching with FR insulation material in between, formed to double rebate profile of minimum size 143mmx60mm (+/-0.3mm). The frame shall have GI Anchor fastners of suitable size for fixing in the opening along with factory made template for SS Ball Bearing Hinges for fixing the fire rated shutters/doors. The door frames and doors shutter shall be powder coated with approved fire ressistant paint & Primers etc... all complete as per direction of Engineer-in-charge.

256

-

-

... More
Providing and fixing fire vision panel of requierd size with clear, toughened, interlayered, non-wired, 120minutes fire ressistant glass panes of 5mm thick on sides of the door shutters including GI U beading & Ceramic tape as required

2.4

-

-

... More
Providing and fixing SS Door Closure on the fire door shutters as required

60

-

-

... More
Providing & fixing Dead Lock with 70mm cylinder on fire door shutters as required.

40

-

-

... More
Providing & fixing of SS Pull Handle of 300mm in size.

60

-

-

... More
Providing and fixing panic bar-Single Leaf, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.

20

-

-

... More
Providing and fixing panic bar-Double Leaf, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.

40

-

-

... More
Subhead : FIRE SEALANT APPLICATION

-

-

-

... More
Supply and Fixing of load bearing Fire stop mortart system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1 g/l as per LEED 2009. Firestop installation should be done by trained applicators and in accordance with manufacturer's guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemical anchoring along the length and breadh of the shaft and provide 2 layers of chicken mesh etc.,as the base for fire mortar at 65mm thickness having load bearing capacity of 200kg/sq.mtr, For shaft size more than 0.64 sqmtr proper engineering judgement needs to be submitted through the manufacturer. Applicator needs to submit complete installation report for inspection purpose.

266

-

-

... More
Subhead : PUBLIC ANNOUNCING SYSTEM

-

-

-

... More
"SITC of 8 zone IP based, digital Voice Alarm controller expandable upto 128 zones. The voice alarm controller shall support multi channel audio and shall be able to connect directly over Ethernet (no other protocol accepted). It shall be having in-built memory of minimum 500 Mb and shall be able to broadcast the messages to any zone in the network as per the configuration. It should have functions like the audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. It shall include PTT microphone for emergency manual announcements. The voice alarm controller shall be integrated with addressable fire alarm system for zone wise evacuation at the event of an emergency. The Voice alarm controller should also have the following functions: 255 Priorities Time schedule broadcasts Capable of amplifier redundancybr . 8 trigger inputs/outputsbr . Hospital codes (Code Blue/Red/Pink/White etc) broadcasting (customizable as per customer). PA System Management software with one server & client licence. It should connect with upto minimum 20 controllers. Administrator can decide No. of users and define user authorities freely. It Can display all equipment status and indicate fault alarm location. It Can record and read history operation and fault logs. It Support Text-to-Speech (TTS) function. It shall support uploading of floor maps for effective management with broadcast details etc. Audio files stored on the server can be played in any zone on the system network. This shall be provided with desktop PC of same specification as that mentioned in fire alarm GUI. Controller Requires Network Resource Interface, 4 channels network audio source, with maximum of 32 dry contacts in and 8 try contacts out. (Price of desktop PC Exclusive)

5

-

-

... More
SITC of 480 W Power Amplifier Speaker Output 4~16 Low-Z output, 480W,70V(10.7), 100V (21.7) Frequency response of 60 Hz~15 kHz ( ± 3 dB ), S/N 80dB, Protection like - AC Fuse × 15 A AC FUSE×1, Current limiter, short circuit and thermal protection circuits. It should have D/A converter and all accessories required.

1

-

-

... More
SITC of 480 W Power Amplifier Speaker Output 4~16 Low-Z output, 480W,70V(10.7), 100V (21.7) Frequency response of 60 Hz~15 kHz ( ± 3 dB ), S/N 80dB, Protection like - AC Fuse × 15 A AC FUSE×1, Current limiter, short circuit and thermal protection circuits. It should have D/A converter and all accessories required.

20

-

-

... More
SITC of Metal Grille 6W Ceiling Speaker with max SPL 1M/1W 96dB . Frequency response of 80Hz- 20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W

780

-

-

... More
SITC of Metal Grille 6W Ceiling Speaker with max SPL 1M/1W 96dB . Frequency response of 80Hz- 20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W

120

-

-

... More
Speaker Cable - Supplying and drawing of 2 Core x 1.5sq.mm flexible armored Speaker cable for speakers through existing PVC conduit with all accessories as required for complete installation and as instructed by engineer in charge/ consultant and making good all damages made for installation.

35000

-

-

... More
HEATING, VENTILATION AND AIR CONDITIONING (HVAC) AND IBMS WORKS - Sub head : WATER CHILLING PLANT

-

-

-

... More
Supply at site including local transport with full cover insurance, fire or any other contigencies, unload, store, handle, erect, balance, test and commission the entire water chilling plant as per specifications including all accessories as specified for water chilling plant. WATER COOLED TWIN SCREW CHILLER - (R-134A/410) EACH WITH SEMI SEALED / SEALED, SINGLE / MULTIPLE COMPRESSOR OF MINIMUM CAPACITY 400 TR. Minimum Overall Chiller efficiency offered shall have COP ≥ 6.2 / IPLV ≥ 8.1 at ANSI / AHRI 550/590 condition reference to ECBC + Buildings 2017. Summer Ambient conditions: DBT- 95 deg F, WBT- 82 Deg F Comprising of Screw Compressor as per specifications. Drive motors of suitable ratings 415+/- 10% Volts 50 Hz AC supply and starter panel with soft starter. Water cooled condensor with all accessories. Automatic capacity control unit to regulate the capacity down to 25%. Micro-processor control panel. Building management system compatible software Data Link / Micro Gateway for integration with third -party BMS on Modbus / BACNET protocol, Safety controls as per spec. wiring and interlock between pumps shall be included in the chiller cost. The cost for additional incoming metering panel for each chiller to be included in the chiller.Water cooled chiller with all accessories: LOT-integral mounting frame for all the components. LOT-refrigerant piping & valves, LOT-insulation of chiller and suction line, LOT-first charge of refrigerant and lube oil, LOT-vibration isolation pads. LOT-Thermometer for water inlet and outlet and water flow switches. MCCBs as a part of the chiller. Copper cable & isolators for chiller to be included in the chiller cost. Isolators at the incoming side including capacitor power supply and earthing will be terminated by other agencies. Power supply and earthing will be terminated in the isolater by other agencies. The scope also includes, R.C.C foundation along with PCC/RCC sub base with fixing of foundation bolts and nuts, spring mounts and finishing the slabs as well as openings and finishing of civil structures.

4

-

-

... More
Supply at site including local transport with full cover insurance, fire or any other contigencies, unload, store, handle, erect, balance, test and commission the entire water chilling plant as per specifications including all accessories as specified for water chilling plant. WATER COOLED TWIN SCREW CHILLER WITH VFD - (R-134A/410) EACH WITH SEMI SEALED / SEALED, SINGLE / MULTIPLE COMPRESSOR OF MINIMUM CAPACITY 400 TR. Minimum Overall Chiller efficiency offered shall have COP ≥ 6.2 at ANSI/AHRI 550/590 condition reference to ECBC + Buildings 2017 / IPLV ≥ 9.5 Summer Ambient conditions: DBT-95 deg F, WBT- 82 Deg F Comprising of Screw Compressor as per specifications. Drive motors of suitable ratings 415+/- 10% Volts 50 Hz AC supply and starter panel with soft starter. Water cooled condensor with all accessories. Automatic capacity control unit to regulate the capacity down to 25%. Micro-processor control panel. Building management system compatible software Data Link / Micro Gateway for integration with third -party BMS on Modbus / BACNET protocol, Safety controls as per spec. wiring and interlock between pumps shall be included in the chiller cost. The cost for additional incoming metering panel for each chiller to be included in the chiller. Water cooled chiller with all accessories. LOT-integral mounting frame for all the components, LOT-refrigerant piping &valves LOT-insulation of chiller and suction line, LOT-first charge of refrigerant and lube oil, LOT-vibration isolation pads. LOT-Thermometer for water inlet and outlet and water flow switches. MCCBs as a part of the chiller. Copper cable & isolators for chiller to be included in the chiller cost. Isolators at the incoming side including capacitor power supply and earthing will be terminated by other agencies. Power supply and earthing will be terminated in the isolater by other agencies. The scope also includes, R.C.C foundation along with PCC/RCC sub base with fixing of foundation bolts and nuts, spring mounts and finishing the slabs as well as openings and finishing of civil structures

1

-

-

... More
Sub head : PUMPS AND COOLING TOWER

-

-

-

... More
Supply, installation, testing &commissioning the chilled water primary pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required&lHorizontal Split casing Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications: Capacity : 960 USgpm, 1440rpm Head : 45 feet Motor : Efficiency class: IE 3,

5

-

-

... More
Supply, installation, testing & commissioning the chilled water secondary pumps as per specification including all accessories as specified and as required. Including Factory made base frame &fixing foundation with necessary fittings as required. Horizontal Split casing Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications: Capacity : 960 USgpm, 1440rpm Head : 100 feet Motor : Efficiency class: IE 3.

5

-

-

... More
Supply, Installation, Testing &commissioning of Variable Frequency Drive complete IP 20 VSPS control panel (IP 55 if panel is to be installed under open air) consisting of adjustable frequency drive (AFD) for each pump, one dedicated microprocessor based pump controller per zone housed within this enclosure panel with parallel pumping software duly down loaded and single / multiple differential pressure sensor / transmitters as per the site requirement. The entire system along with secondary pumps as described above must be sourced from single manufacturer only, to ensure unit responsibility. The VFD should be incorporated with RFI (radio frequency interface) filters which can control THDi [Total Harmonic Distortion Current] below 5%, auto bypass starter compactable to the third party bms

1

-

-

... More
Supply, Installation, testing & commsssioning the condenser water pumps as per specification including all accessories as specified and as required. Including Factory made base frame &fixing foundation with necessary fittings as required. Horizontal Split casing Condenser water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications: Capacity : 1600 USgpm, 1440rpm Head : 70 feet Supply, installation, testing commissioning the chilled water secondary pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required. Horizontal Split casing Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications: Capacity : 960 USgpm, 1440rpm. Head : 100 fee Motor : Efficiency class: IE 3,

5

-

-

... More
Supply, Installation, testing &commissioning the cooling towers as per specification including all accessories as specified and as required. COOLING TOWERS of actual capacity complete in all respects as per technical specifications and equipment schedule complete with FRP casing, FRP fan cylinder, PVC louvers, PVC drift eliminator polypropelene nozzles, drive assembly, HDG fan guard/bird screen, non-clogging nozzle type water distribution system. PVC fill, aluminium ladder with railings, make up water, quick fill, drain over flow connections etc. as per specifications. Including R.C.C foundation along with PCC/RCC sub base, fixing with bolts and nuts and finishing the slabs or any opening etc. 400 TR - CTI/JCI approved induced draft, cross flow cooling tower with vertical air discharge. EWT = 97.5 degree F LWT = 90 degree F WET bulb = 82 degree F Flow rate = 1600 US gpm Motor suggested - 20 HP

5

-

-

... More
Sub head : DOUBLE SKIN AIR-HANDLING UNITS WITH VFD AND PLUG FANS AND THERMAL BREAK

-

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHU's - 50 mm Static 35 TR, 14000 cfm, 28 sqft./ 4row (Double Skin Floor mounted Horizontal AHU with mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHU's - 50 mm Static 38 TR, 15200 cfm, 30.4 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 34 TR, 13600 cfm, 27.2 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHU's - 50 mm Static 33 TR, 13200 cfm, 26.4 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHU's - 50 mm Static 33 TR, 11920 cfm, 23.84 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 33 TR, 12280 cfm, 24.56 sqft./ 4row(Double Skin Floor mounted Horizontal AHU)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHU's - 50 mm Static 32 TR, 12800 cfm, 25.6 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

4

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHU's - 50 mm Static 30 TR, 12000 cfm, 24 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

3

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 30 TR, 11120 cfm, 22.24 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHU's - 50 mm Static 30 TR, 11160 cfm, 22.32 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 30 TR, 10400 cfm, 20.8 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 28 TR, 11280 cfm, 22.56 sqft./ 4row(Double Skin Floor mounted Horizontal AHU)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 28 TR, 11080 cfm, 22.16 sqft./ 4row;(Double Skin Floor mounted Horizontal AHU)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 24 TR, 9200 cfm, 18.4 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 22 TR, 8800 cfm, 17.6 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 22 TR, 8200 cfm, 16.4 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 22 TR, 8800 cfm, 17.6 sqft./ 4row(Double Skin Floor mounted Horizontal AHU)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 20 TR, 8000 cfm, 16 sqft./ 4row(Double Skin Floor mounted Horizontal AHU with mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 20 TR, 8000 cfm, 16 sqft./ 4row(Double Skin Floor mounted Horizontal AHU)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 18 TR, 7200 cfm, 14.4 sqft./ 6 row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 17 TR, 6800 cfm, 13.6 sqft./ 4 row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 16 TR, 6400 cfm, 12.8 sqft./ 4 Row(Double Skin Floor mounted Horizontal AHU with mixing Box)

3

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 14 TR, 5600 cfm, 11.2 sqft./ 4 Row(Double Skin Floor mounted Horizontal AHU with mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 14 TR, 5080 cfm, 10.16 sqft./ 4 Row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 12 TR 4440 CFM 8.8 sqft / 4 row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 12 TR 4130 CFM 8.26 sqft / 4 row.(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 11 TR 4400 CFM 8.8 sqft / 4 row(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
SITC of 11 TR 3920 CFM 7.8 sqft / 4 row. (Double Skin Floor mounted Horizontal AHU with mixing Box)(Detailed Technical Specification attached)

1

-

-

... More
SITC of 11 TR 3680 CFM 7.8 sqft / 4 row. (Double Skin Floor mounted Horizontal AHU with mixing Box)(Detailed Technical Specification attached)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 10 TR 4000 CFM 8 sqft / 4 row.(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 10 TR 4500 CFM 9 sqft / 4 row.(Double Skin Floor mounted Horizontal AHU with mixing Box, 3 KW heater)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 9TR 3600 CFM 7.2 sqft / 4 row.(Double Skin Floor mounted Horizontal AHU with mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 8 TR 3200 CFM 6.4 sqft/ 4 row.(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 7 TR 3500 CFM 7 sq.ft/ 4 row. Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 6 TR 2400 CFM 4.8 sqft/ 4 row.(Double Skin Floor mounted Horizontal AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 16 TR, 6400 cfm, 12.8 sqft./ 4 Row(Double Skin Ceiling suspended AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 10 TR 4000 CFM 8 sqft/ 6 row.(Double Skin ceiling suspended AHU with 2 X 3 KW Heater, mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 9TR 3600 CFM 7.2 sqft / 4 row.(Double Skin ceiling suspended AHU with Mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 9 TR, 2740 cfm, 5.48 sqft./ 6 Row(Double Skin ceiling suspended AHU with Mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 8 TR, 3200 cfm, 6.4 sqft./ 4 Row(Double Skin ceiling suspended AHU with Mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 8 TR, 2260 cfm, 4.52 sqft./ 6 Row(Double Skin ceiling suspended AHU with Mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 7 TR 2800 CFM 5.6 sqft/ 4 row.(Double Skin ceiling suspended AHU with Mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static. 6 TR 2400 CFM 4.8/ 4 row.(Double Skin ceiling suspended AHU with mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 5 TR, 2000 cfm, 4 sqft./ 4 Row (Double Skin ceiling suspended AHU with Mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 4 TR 1600 CFM 3.2/ 4 row.(Double Skin ceiling suspended AHU with Mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 9TR 3600 CFM 7.2/ 4 row.(Double Skin ceiling suspended AHU)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 8 TR 3200 CFM 6.4/ 4 row.(Double Skin ceiling suspended AHU)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 7 TR 2800 CFM 5.6/ 4 row.(Double Skin ceiling suspended AHU)

3

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 6 TR 2400 CFM 4.8/ 4 row. (Double Skin ceiling suspended AHU)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 5 TR, 2000 cfm, 4 sqft./ 4 Row (Double Skin ceiling suspended AHU)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 4 TR 1600 CFM 3.2/ 4 row.(Double Skin ceiling suspended AHU)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 27 TR, 10520 cfm, 21.04 sqft./ 4 row(Double Skin Floor mounted Horizontal AHU with fine filter, mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 18 TR, 7200 cfm, 14.4 sqft./ 4 row (Double Skin Floor mounted Horizontal AHU with fine filter, mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 11 TR 4400 CFM 8.8 sqft./ 4 row.(Double Skin Floor mounted Horizontal AHU with fine filter, mixing Box)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 9TR 3600 CFM 7.2 sqft./ 4 row.(Double Skin Floor mounted Horizontal AHU with fine filter, mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 6 TR 2400 CFM 4.8 sqft./ 4 row.(Double Skin Floor mounted Horizontal AHU with fine filter, mixing Box)

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 10 TR, 4400 cfm, 8.8 sqft./ 6 Row - LG 1 CT /FUTURE PET(Double skin floor mounted AHU with VFD, Mixing Box, 6 Row, 10 micron filter, 4400 CFM (Fine filter & 2 x 3 KW heater in Plenumn)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 14 TR, 6400 cfm, 12.8 sqft./ 6 Row -LG 1 CT &Double skin floor mounted Double Decker (1w + 1standby) AHU with VFD, 6 Row, 10 micron filter, 6400 CFM (Fine filter & 2 x 3 KW heater in Plenumn) ;

1

-

-

... More
Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.<br>Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU.<br>" Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost.<br>Fixing with bolts and nuts and finishing the slabs or any opening etc good as same"<br>"Notes: Fine filter efficiency 99.9% down to 5 micron.<br>External Static Pressure for:<br>Operation theater AHU's 100 mm Static<br>Cathlab, CT/MRI- 65 mm Static<br>AHU's with fine filters - 55 mm Static<br>all other AHU's - 50 mm Static"

2

-

-

... More
Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost.Fixing with bolts and nuts and finishing the slabs or any opening etc good as same"<br>"Notes: Fine filter efficiency 99.9% down to 5 micron.<br>External Static Pressure for:<br>Operation theater AHU 100 mm Static Cathlab, CT/MRI- 65 mm Static<br>AHU's with fine filters - 55 mm Static all other AHUs - 50 mm Static;6 TR, 2400 cfm, 6 sqft./ 8 Row - LG 1 Brachy ;(Double Skin Floor mounted Horizontal AHU with mixing box, 10 micron pre filters, 5 micron fine filters, heater capacity 2 x 3KW, Thermal break)

1

-

-

... More
Supply, Installation, testing & commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost.& Fixing with bolts and nuts and finishing the slabs or any opening etc good as same;Notes: Fine filter efficiency 99.9% down to 5 micron.<br>External Static Pressure for:<br>Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Statict;AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static;10 TR, 4000 cfm, 8 sqft./ 6 Row - Medical accelerator (Double Skin Floor mounted Double decker (1w + 1standby) AHU with 10 micron pre filters, Thermal break) (fine filters, heater capacity 2 x 3KW in plenumn)"

4

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 5 TR, 2000 cfm, 4 sqft./ 6 Row - Ground - Procedure Double skin ceiling suspended AHU with fine filter, 2 x 3 KW heaters, mixing box, thermal break.

1

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 10 TR, 4200 cfm, 8.4 sqft./ 6 Row - Ground MRI/CT (Double skin floor mounted AHU with VFD, Mixing Box, 6 Row, 10 micron filter, 4200 CFM (Fine filter & 2 x 3 KW heater in Plenumn)

2

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 7 TR, 3200 cfm, 6.4 sqft./ 8 Row - FIFTH - OT(Double Skin Floor mounted Horizontal AHU with mixing box, 10 micron pre filters , 5 micron fine filters, heater capacity 2 x 3KW, Thermal break)

3

-

-

... More
Supply, Installation, testing &commissioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFDs shall be used. All AHUs will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU.Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHUs to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the the inlete and outlet of coiling coils for pressure gauges (only provision), duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective pannel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc good as same Notes: Fine filter efficiency 99.9% down to 5 micron. External Static Pressure for Operation theater AHUs 100 mm Static Cathlab, CT/MRI- 65 mm Static AHUs with fine filters - 55 mm Static all other AHUs - 50 mm Static 8 TR, 3200 cfm, 6.4 sqft./ 8 Row - FIFTH - OT(Double Skin Floor mounted Horizontal AHU with mixing box, 10 micron pre filters , 5 micron fine filters, heater capacity 2 x 3KW, Thermal break.

2

-

-

... More
Sub head: TREATED FRESH AIR UNIT WITH HEAT RECOVERY WHEEL, VFD, SUPPLY AND RETURN FANS AND FAN COIL UNITS WITH VALVE STATION

-

-

-

... More
Supply at site, including, local transport, unload, store, handle, erect, balance and commission of the entire HRW as per specifications including all accessories as specified and as required. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F Return Air condition: DBT- 75 Deg F , RH– 55% Supply Fan Static - 60 to 70 mm WG Return fan - 40 mm to 60 mm WG Efficiency 80- 85% TFA -1,2 - HRW at LINAC AHU Room and LOWER GROUND FLOORTFA - 15 TR AHU, 6 sq.ft./ 8 Row coil with 3000 CFM Supply fan, 2700 CFM Return fan and heater of 2 x 3KW.

2

-

-

... More
Supply at site, including, local transport, unload, store, handle, erect, balance and commission of the entire HRW as per specifications including all accessories as specified and as required. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F Return Air condition: DBT- 75 Deg F , RH– 55% Supply Fan Static - 60 to 70 mm WG Return fan - 40 mm to 60 mm WG Efficiency 80- 85% TFA -3 LOWER GROUND, GROUND, FIRST, SECOND, - LEFT SIDE<br>TFA - 56 TR AHU, 22 sq.ft./ 8 Row coil with 11000 CFM Supply fan, 7500 cfm Return fan with Heater.

1

-

-

... More
Supply at site, including, local transport, unload, store, handle, erect, balance and commission of the entire HRW as per specifications including all accessories as specified and as required. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F Return Air condition: DBT- 75 Deg F , RH– 55% Supply Fan Static - 60 to 70 mm WG Return fan - 40 mm to 60 mm WG Efficiency 80- 85% TFA - 31 TR AHU, 12.4 sq.ft./ 8 Row coil with 6200 CFM Supply fan, 6580 cfm Return fan with Heater.

1

-

-

... More
Supply at site, including, local transport, unload, store, handle, erect, balance and commission of the entire HRW as per specifications including all accessories as specified and as required. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F Return Air condition: DBT- 75 Deg F , RH– 55% Supply Fan Static - 60 to 70 mm WG Return fan - 40 mm to 60 mm WG Efficiency 80- 85% TFA - 65 TR AHU, 25.5 sq.ft./ 8 Row coil with 12750 CFM Supply fan, 7500 cfm Return fan with Heater

1

-

-

... More
Supply at site, including, local transport, unload, store, handle, erect, balance and commission of the entire HRW as per specifications including all accessories as specified and as required. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F Return Air condition: DBT- 75 Deg F , RH– 55% Supply Fan Static - 60 to 70 mm WG Return fan - 40 mm to 60 mm WG Efficiency 80- 85% TFA - 65 TR AHU, 24.7 sq.ft./ 8 Row coil with 12000 CFM Supply fan, 8000 cfm Return fan with Heater

1

-

-

... More
Supply at site, including, local transport, unload, store, handle, erect, balance and commission of the entire HRW as per specifications including all accessories as specified and as required. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F Return Air condition: DBT- 75 Deg F , RH– 55% Supply Fan Static - 60 to 70 mm WG Return fan - 40 mm to 60 mm WG Efficiency 80- 85% TFA -7 TERRACE FLOOR - OT TFA - 23 TR AHU, 9.2 sq.ft./ 8 Row coil with 4600 CFM Supply fan, 4150 cfm Return fan with Heater

1

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin &with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)0.75 TR Hideway FCU

3

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 1 TR Hideway FCU

150

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 1.25 TR Hideway FCU

24

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)]1.5 TR Hideway FCU

60

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 2 TR Hideway FCU

24

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 2.5 TR Hideway FCU

5

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF)<br>3 TR Hideway FCU

5

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE (ON/OFF) 3.5 TR High static FCU

8

-

-

... More
Sub head : CASSETTE TYPE UNITS

-

-

-

... More
Supply, installing, testing and commissioning of following cassette units with drain pump &fresh air provision as per specification including all accessories as specified and as required 0.75 TR Cassette unit

2

-

-

... More
Supply, installing, testing and commissioning of following cassette units with drain pump &fresh air provision as per specification including all accessories as specified and as required 1 TR Cassette unit

2

-

-

... More
Supply, installing, testing and commissioning of following cassette units with drain pump &fresh air provision as per specification including all accessories as specified and as required 1.75 TR four way cassette unit

2

-

-

... More
Supply, installing, testing and commissioning of following cassette units with drain pump &fresh air provision as per specification including all accessories as specified and as required 2 TR four way cassette unit

4

-

-

... More
Supply, installing, testing and commissioning of following cassette units with drain pump &fresh air provision as per specification including all accessories as specified and as required 3.5 TR four way cassette unit

1

-

-

... More
Sub head : CHILLED WATER PIPING AND VALVES

-

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 450 mm dia.

175

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 400 mm dia.

150

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 350 mm dia.

10

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 300 mm dia.

65

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) ;250 mm dia.

175

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 200 mm dia.

140

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 150 mm dia.

150

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 125 mm dia.

200

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 100 mm dia.

480

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 80 mm dia.

625

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 65 mm dia.

1070

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) ;50 mm dia.

1190

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 40 mm dia.

1300

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 32 mm dia.

995

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 25 mm dia.

1350

-

-

... More
Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 20 mm dia.

2650

-

-

... More
Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection. 450 mm dia.

180

-

-

... More
SiteSite fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection. 250 mm dia.

185

-

-

... More
Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection. 25 mm dia. GI

150

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 32 mm dia. PVC

175

-

-

... More
Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 25 mm dia. PVC

500

-

-

... More
Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 450 mm dia.

2

-

-

... More
Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 300 mm dia.

2

-

-

... More
Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 250 mm dia.

32

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation:Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 200 mm dia.

2

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation:Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 200 mm dia.

4

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation:Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 125 mm dia.

6

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation:Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 100 mm dia.

27

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation:Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 80 mm dia.

23

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation:Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 65 mm dia.

84

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation:Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 50 mm dia.

48

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation:Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 40 mm dia.

88

-

-

... More
Supplying, fixing, testing and commissioning of following Ball valves and Drain valves for AHUs, plant room, shaft riser &chilled water piping adequately supported as per specifications. 32 mm dia

48

-

-

... More
Supplying, fixing, testing and commissioning of following Ball valves and Drain valves for AHUs, plant room, shaft riser &chilled water piping adequately supported as per specifications. 25 mm dia

37

-

-

... More
Supplying, fixing, testing and commissioning of following Ball valves and Drain valves for AHUs, plant room, shaft riser &chilled water piping adequately supported as per specifications. 20 mm dia

8

-

-

... More
Supply, installation, testing &commissioning of the following non return valves as per the specifications and as required. Non Return valves up to 65mm size shall be of gun metal with screwed female ends. Valves of 65mm and above shall be of CI with flanged ends. PN 16 pressure rating, EPDM seal. Non- Return Valve of size:- 200 mm dia.

10

-

-

... More
BALANCING VALVE WITH PROVISION FOR FLOW MEASURMENT:Supply, installation, testing &commissioning of Balancing valve with built in measuring facility, C.I Body with EPDM seal, long pitch with protected out pipe insulation PN 16 pressure rating for chilled water as specified. Balancing Valve with 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections; Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/-, necessary insulation as per specification. Balancing valve with built in measuring facility 200 mm dia

5

-

-

... More
SUCTION GUIDE with strainer:Supply, installation, testing &commissioning of the following suction guides as per the specifications and as required. Size: 200 mm dia.

10

-

-

... More
Y STRAINER FOR AHUs: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 100 mm dia

3

-

-

... More
Y STRAINER FOR AHUs: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 80 mm dia

1

-

-

... More
Y STRAINER FOR AHUs: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 65 mm dia

26

-

-

... More
Y STRAINER FOR AHUs: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 50 mm dia

21

-

-

... More
Y STRAINER FOR AHUs: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 40 mm dia

41

-

-

... More
Y STRAINER FOR AHUs: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 32 mm dia

23

-

-

... More
Y STRAINER FOR AHUs: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of 25 mm dia

10

-

-

... More
PRESSURE GAUGE - For chiller, pumps, AHU: Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection: Brass, NPS 12mm dia bottom-outlet type, Dial: Satin-faced, non-reflective aluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification.

278

-

-

... More
THERMOMETERS - For chiller, pumps, AHU: Supply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification.

278

-

-

... More
Supply, installation, testing &commissioning of differential pressure switch as per the specifications and as required.

5

-

-

... More
Supply, installation, testing & commissioning of the following motorized cut off valves as per the specifications and as required. Cl Body, minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required. Size: 200 mm dia.

5

-

-

... More
1500 L Pressurized Tank: Design, supply, installation, testing and commissioning of Pressurised chilled water expansion tank with insulation, Make up connection for closed loop system along with necessary pneumatic devices and accessories and MS 'C' section section supports in order to keep chilled water under pressure. The tank shall be precharged steel tank with replacable heavy duty butyl rubber bladder. The tank shall have 50mm system connection and 20mm drain and charging valve connection to facilitate on-site charging of tank. The tank shall be fitted with lifting rings and floor mounting skirt for vertical installation. The tank shall be constructed according to section 8 of ASME boiler and pressure vessel code and stamped 125psi working pressure.The contractor shall submit calculation regarding the above data. Pumps shall be of N+1 configuration. including with control wiring.

1

-

-

... More
Supply, installation, testing &commissioning of a common air separator on the chilled water return line located at the pump suction and suitable for Secondary pump water flow; the separator shall be complete with high capacity air vent, flanges, service valve, non return valve, isolation butterfly valve for makeup water inlet. Capacity suitable for 3840 USGPM and 450mm NB CHW Header line.

1

-

-

... More
AUTO AIR VENTS including Ball Valves: Supply &install of airvents / purge valves including 15mm Ball Valves at the highest points in chilled water piping complete each floor with pipes nipple welded to pipe, hex nipple, socket, U-pipe connection at outlet of air vent etc. as required.

125

-

-

... More
Supply and fix flexible connections with control rods for pumps and chiller. Size: 200 mm dia.

30

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 &DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification. 100 mm dia.

3

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification. 80 mm dia.

1

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification. 65 mm dia.

26

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification. 50 mm dia.

21

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification. 40 mm dia.

41

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification. 32 mm dia.

23

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification. 25 mm dia.

10

-

-

... More
Sub Head : CONDENSER WATER PIPING AND VALVES

-

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 500 mm dia

250

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 250 mm dia.

185

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 125 mm dia.

100

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same. (Note: Wall openings for pipes & ducts, AHU Room and making good of opening to the complete satisfaction, pedestal for equipment are under the scope of HVAC contractor.) 100 mm dia.

200

-

-

... More
Supply, installation, testing &commissioning of the following butterfly valves as per the specifications and as required. BUTTERFLY VALVE (MANUAL): Size- 250 mm

30

-

-

... More
Supplying, fixing, testing and commissioning of following non return valves, in the condenser water piping and adequately supported as per specifications. Non- Return Valve of 250 mm dia

5

-

-

... More
Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required. Size: 250 mm dia

5

-

-

... More
Supply and fix flexible connections with control rods for pumps, cooling tower &condenser. Size: 250 mm NB

20

-

-

... More
Supply, installation, testing &commissioning of Balancing Valve, with built in measuring facility with C.I Body, 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections;Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/- Size: 250 mm NB.

10

-

-

... More
Supply, installation, testing and commissioning of 4"Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

30

-

-

... More
Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection: Brass, NPS 12mm dia bottom-outlet type, Dial: Satin-faced, non-reflective aluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification.

30

-

-

... More
Supply, installation, testing &commissioning of differential pressure switch as per the specifications and as required.

5

-

-

... More
Supply, installation, testing &commissioning of the following motorized cut off valves as per the specifications and as required. Cl Body, Nylon coated DI disc, EPDM seal, minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required. Size: 250 mm dia.

10

-

-

... More
Sub Head : DUCTING, GRILLS, DIFFUSER AND INSULATION

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

12350

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

7600

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

2415

-

-

... More
16.12.1.4 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

110

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major & Minor OTs, CT/MRI, Bunker, Cath Lab etc. Thickness 0.80 mm Al. Sheet ducting

1955

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major &Minor OTs, CT/MRI, Bunker, Cath Lab etc. Thickness 1.00 mm Al. Sheet ducting

1765

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major &Minor OTs, CT/MRI, Bunker, Cath Lab etc. Thickness 1.25 mm Al. Sheet ducting

100

-

-

... More
Supply installing, testing and commissioning of fine filters of efficiency 99.9% down to 5 microns in filter plenum in suitable frame work for OT, Medical accelerator, MRI/CT: Fine filters - for Lower Ground Medical accelerator as per dwg, 4000 cfm

4

-

-

... More
Supply installing, testing and commissioning of fine filters of efficiency 99.9% down to 5 microns in filter plenum in suitable frame work for OT, Medical accelerator, MRI/CT: Fine filters - for GF - MRI/CT as per dwg, 4800 cfm

1

-

-

... More
Supply installing, testing and commissioning of fine filters of efficiency 99.9% down to 5 microns in filter plenum in suitable frame work for OT, Medical accelerator, MRI/CT: Fine filters - for GF - MRI as per dwg, 4200 cfm

1

-

-

... More
Supply installing, testing and commissioning of fine filters of efficiency 99.9% down to 5 microns in filter plenum in suitable frame work for OT, Medical accelerator, MRI/CT: Fine filters - for LGF 1 - PET CT as per dwg, 4400 cfm

2

-

-

... More
Supply installing, testing and commissioning of fine filters of efficiency 99.9% down to 5 microns in filter plenum in suitable frame work for OT, Medical accelerator, MRI/CT: Fine filters - for LGF 1 - CT as per dwg, 6400 cfm

1

-

-

... More
Supply installing, testing and commissioning of (Factory Fabricated) HEPA filters of efficiency 99.9% down to 0.3 microns in filter plenum of 18 Gauge with rubber Gaskets In SS suitable frame work with 70% perforated grille TOTAL HEPA FILTRATION AREA -5.4 Sq.mt: Ultra Clean Ventilation arrangement of A/C inside the Lab comprising of SS supply plenum including the 1.5" flanges on all sides., material SS 304, 0.8mm, 2B finish. HEPA filters 0.3microns, efficiency 99.97% EU13 Sizes of - 1200X900X150 - 4 Nos, 900 x 600 x 150mm- 2 Nos. The HEPA filters will be fixed to the plenum using M6 SS rode, 304 Q type SS bolts and nuts). SS perforated sheets Mat finish. Hepa filters (550 cfm x 4 nos.+ 500 x 2 Nos.)

6

-

-

... More
Supply, install, testing and commissioning of strip heaters comprising thermostat, humidistat, safety thermostat, contactors. Minimum capacity of strip heaters shall be 3 kW 3 KW

14

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

25

-

-

... More
16.16.a : Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

65

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 300x300

989

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 375x375

700

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 450x450

31

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 525x525

1

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 600x600

1

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 RD: 225X225

8

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 300x300

1026

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 375x375

713

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 450x450

23

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 525x525

1

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 600X600

1

-

-

... More
Supply installing, testing and commissioning of perforated aluminium grille for return with VCD and 10 Micron Filter in OT

38

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards andspecification. 250 mm dia

100

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification. 300 mm dia

2000

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification 350 mm dia

850

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification. 400 mm dia

100

-

-

... More
Supply, Fabrication, installation and testing of the insulated flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification - for exhaust 150 mm dia.

1450

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 300 X 300 X 350H

1

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 350 X 350 X 450H

989

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 450 X 450 X 450H

700

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 600 X 600 X 450H

33

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 600 X 150 X 450H

1

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes750 X 150 X 450H

1

-

-

... More
SITC of Factory made fresh air dampers with louvers and control lever, filter etc as required. (as per drawing)

16

-

-

... More
SITC of Factory made fresh air dampers having 20 micron filter with louvers and control lever. (for OT as per drawing)

3

-

-

... More
Supply, fix, balance and commissioning of louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, brass bushings complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges, fixing arrangement etc, as per specifications. Al. volume control duct damper.

110

-

-

... More
Supply and fix UL 555 certified, 1 1/2 hour fire hour fire rated fire dampers in air ducts (main line) with fusible link µswitch to shut of corresponding AHU (including control cable).

80

-

-

... More
VAV (Variable Air Volume) unit: SITC of VAVs of following CFMs for supply air in rectangular ducts including thermostat and controls. Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 1200 cfm

2

-

-

... More
VAV (Variable Air Volume) unit: SITC of VAVs of following CFMs for supply air in rectangular ducts including thermostat and controls. Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 1400 cfm

4

-

-

... More
VAV (Variable Air Volume) unit: SITC of VAVs of following CFMs for supply air in rectangular ducts including thermostat and controls. Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 1600 cfm

4

-

-

... More
Thermal insulation: Supply &fixing of 8 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3.

14650

-

-

... More
Acoustic insulation:Supply &fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140-180kg/m3

3550

-

-

... More
Non ac area duct insulation: Supply & fixing of 19 mm thick Class O nitrile rubber insulation with adhesive as per the recommendation of the manufacturer with density 45-55kgm3

8050

-

-

... More
Sub head: VENTILATION SYSTEM

-

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen 1250 cfm Exhaust Blower with NRD, fine Filter for active toilet, hot lab etc - Static 35 mm

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen 3300 cfm Exhaust blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 3000 cfm Exhaust blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 2700 cfm Exhaust blower

3

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 2600 cfm Exhaust blower

3

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 2500 cfm Exhaust blower

3

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 2100 cfm Exhaust blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 2000 cfm Exhaust blower

2

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 1800 cfm Exhaust blower

2

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 1750 cfm Exhaust blower

2

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 1700 cfm Exhaust blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 1500 cfm Exhaust blower

4

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 1400 cfm Exhaust blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 850 cfm Exhaust blower

2

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 800 cfm Exhaust blower

3

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 750 cfm Exhaust blower

4

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 450 CFM Exhaust blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 600 CFM Exhaust blower

2

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 400 cfm Exhaust blower

8

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 350 cfm Exhaust blower

7

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 300 cfm Exhaust blower

2

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 250 cfm Exhaust blower

4

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 200 cfm Exhaust blower

6

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 150 cfm Exhaust blower

6

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 100 cfm Exhaust blower

48

-

-

... More
Axial Fans - for Toilet, Plant room exhaust &Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single/three phase motor and flexible connection to connect with ducting / plenum, louvers with birdscreen. 80 cfm Exhaust blower

49

-

-

... More
VENTILATION SYSTEM (AHU SECTION) Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work with fan section TEFC sq.cage induction motor of required rating including mounting and fixing arrangements DIDW Centrifugal fan and motor pulley, V-belts and belt guard., and anti vibration springs/ isolator bearings etc. Insulation of all section with fire retardant insulation material as per manufactures standard. Accessories such as: Double canvas connections of fire retardant quality for connecting units to ducting/plenum. Double inlet Double width Centrifugal backward curved Exhaust fans (100 mm static) 20000 cfm Exhaust blower with AIR washer water base - kitchen.

1

-

-

... More
VENTILATION SYSTEM (AHU SECTION) Pre-Plasticised Sheet/ powder coated , Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work with fan section TEFC sq.cage induction motor of required rating including mounting and fixing arrangements DIDW Centrifugal fan and motor pulley, V-belts and belt guard., and anti vibration springs/ isolator bearings etc. Insulation of all section with fire retardant insulation material as per manufactures standard. Accessories such as: Double canvas connections of fire retardant quality for connecting units to ducting/plenum. Double inlet Double width Centrifugal backward curved Exhaust fans (100 mm static) 8500 cfm Fresh air blower

2

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

850

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

42

-

-

... More
Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification. Size: 100mm dia.

1050

-

-

... More
FIRE DAMPERS: Supply and fix UL 555 certified 2 hour fire rated fire dampers with fusible link µswitch including control cable.

3

-

-

... More
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers. Design to be approved (material : Al) Supply air grille/diffuser with vcd

5

-

-

... More
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers. Design to be approved (material : Al) Return air grille/diffuser with vcd

30

-

-

... More
Sub head: ADDITIONAL WORKS

-

-

-

... More
Acoustic Lining of AHU Rooms without Mixing Box /Boxing Insulation for Ceiling suspended AHU Supply & fixing of 15 mm thick acoustic nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 140-180kg/m3.

1050

-

-

... More
UNDER DECK INSULATION - FOR ICU, OPERATION THEATRE, MRI, CT, ISOLATION ROOMS: Supply&fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3.

6400

-

-

... More
Roof(inside) insulation for exposed slabs/walls:Supply fixing of 12 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3.

5700

-

-

... More
PIPE CLEANING AND CHEMICAL WATER TREATMENT FOR CONDENSER WATER: Automatic type Chemical dosing system, for condenser water piping system as per specification and drawing.Total package of flushing, chemical pre-cleaning, passivation and continuos maintenance treatement wih chemicals etc with necessary permanently installed equipments and its controls. This package includes initial analysing of make up water sample.Then programming methods and duration. Accordingly, supply, install, test commission and maintain for a specified period with dosing pumps , tanks, water meters corrosion coupon tanks, valves with required chemicals and its micro-processor based controller with program etc as per specification.Maintaing the clean piping system without corrosion, scale or micro-biological activity for an optimum operational efficiency and handing over the entire system in a healthy condition at the end of the contract which is the suppliers responsibility.

1

-

-

... More
AIR CURTAIN for Entry &Exit: Supply, installing, testing and commissioning of air curtains with GI coated covering, controller & door sensors, all required accessories, maximum velocity (11 m/s), 2 meter wide horizontal air curtains , maximum throw level upto 4mtr of the door height, energy efficient 1phase EC motors & have IP protection 20.

2

-

-

... More
Sub head: ELECTRICAL WORKS

-

-

-

... More
MAIN PUMP PANEL 1:Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. The panel shall complete with incomer & outgoing, Bus Bar Chamber, Volt Meter, Ammeter, fully automatic Star / delta / DOL starters for pumps as per the approved drawing & technical specification, Contactors, Auxiliary contacts, Indicating Lamps, Fuses, Auto / Manual Selector Switches, Manual On / Off Buttons, all internal wiring etc as per the approved drawing and tecnical specification. The price for control panel shall be inclusive of all control cabling for functioning as per the design requirement and Earthing of the panel, all as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions. The panel shall be BMS compatible and CPRI approved. Incomer - 630A, 36 kA, FP thermal magnetic release MCCB + Energy Meter with all accessories - 1 Set.630A 433V, 36kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh. RYB phase indicating LED lamps with control fuses and switches -1Set. Outgoings: 400A, 25/36kA, TP+NL, Thermal Magnetic release MCCB- 2 No. 63A, 25kA, TP+NL, Thermal Magnetic release MCCB + Startor + Accessories - 5 Set. 63A, 25kA, TP+NL, Thermal Magnetic release MCCB as spare - 1 No. Supply, Installation, testing and commisioning.

1

-

-

... More
MAIN PUMP PANEL 2:Fabrication, supply, erection, testing and commissioning of Type Tested Assembly (TTA) cubicle type (panel and all switch gears should be type tested and certification should be submitted) as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. The panel shall complete with incomer & outgoing, Bus Bar Chamber, Volt Meter, Ammeter, fully automatic Star / delta / DOL starters for pumps as per the approved drawing & technical specification, Contactors, Auxiliary contacts, Indicating Lamps, Fuses, Auto / Manual Selector Switches, Manual On / Off Buttons, all internal wiring etc as per the approved drawing and tecnical specification. The price for control panel shall be inclusive of all control cabling for functioning as per the design requirement and Earthing of the panel, all as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions. The panel shall be BMS compatible and CPRI approved. Incomer - 630A, 36 kA, FP thermal magnetic release MCCB + Energy Meter with all accessories - 1 Set. 630A 433V, 36kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:25A, 25kA, TP+NL, Thermal Magnetic release MCCB + Startor + Accessories - 5 Set. 63A, 25kA, TP+NL, Thermal Magnetic release MCCB + Startor + Accessories - 5 Set. 125A, 16kA, TP+NL, Thermal Magnetic release MCCB as spare - 1 No. 63A, 16kA, TP+NL, Thermal Magnetic release MCCB as spare - 1 No. Supply, Installation, testing and commissioning

1

-

-

... More
AHU PANEL / SM DB 1:Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 160A, FP, MCCB Isolator. 160A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement.<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:16-63A, 16kA, TP+NL , Thermal Magnetic release MCCB - 10 Nos. 6-10A, TP+NL MCB - 3 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 2:Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 125A, FP, MCCB Isolator - 1 No. 125A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement.<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches -1Set. Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 8 Nos. Supply, Installation, testing and commisioning.

1

-

-

... More
AHU PANEL / SM DB 3:Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 160A, FP, MCCB Isolator - 1 No. 160A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement.Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:16-25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 14 Nos. 6-10A, TP+NL, MCB - 2 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 14 Nos. 6-10A, TP+NL, MCB - 1 No. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 5 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement.<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh. RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 18 Nos. 6-10A, TP+NL, MCB - 2 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 6 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 13 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 7 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 15 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 8 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 100A, FP, MCCB Isolator - 1 No. 100A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 6-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 6 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 9:Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 160A, FP, MCCB Isolator - 1 No. 160A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 12 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 8 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 11 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 160A, FP, MCCB Isolator - 1 No. 160A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh& RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings-16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 7 Nos. Supply, Installation, testing and commisioning.

1

-

-

... More
AHU PANEL / SM DB 12 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:6-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 10 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 13:Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh. RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings: 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 6 Nos. Supply, Installation, testing and commisioning.

1

-

-

... More
AHU PANEL / SM DB 14 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 160A, FP, MCCB Isolator - 1 No. 160A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 12 Nos. 6-10A, TP+NL, MCB - 7 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 15 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 16 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 16:Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 160A, FP, MCCB Isolator - 1 No. 160A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1Set. Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 12 Nos. 6-10A, TP+NL, MCB - 1 Nos. Supply, Installation, testing and commisioning.

1

-

-

... More
AHU PANEL / SM DB 17 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 15 Nos. 6-10A, TP+NL, MCB - 1 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 18 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 200A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 12 Nos. 6-10A, TP+NL, MCB - 1 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 19 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 100A, FP, MCCB Isolator - 1 No. 100A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 6 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 20 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 63A, FP, MCCB Isolator - 1 No 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 S Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 3 Nos. 6-10A, TP+NL, MCB - 2 Nos. Supply, Installation, testing and commisioning

1

-

-

... More
AHU PANEL / SM DB 21 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 63A, FP, MCCB Isolator - 1 No.63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 4 Nos. 6-10A, TP+NL, MCB - 2 Nos.

1

-

-

... More
AHU PANEL / SM DB 22 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 100A, FP, MCCB Isolator - 1 No. 100A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement.<br>Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 7 Nos.

1

-

-

... More
AHU PANEL / SM DB 23 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 100A, FP, MCCB Isolator - 1 No. 100A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh.RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings-16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 2 Nos. 6-10A, TP+NL, MCB - 7 Nos.

1

-

-

... More
AHU PANEL / SM DB 24: Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1Set. Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 3 Nos.

1

-

-

... More
AHU PANEL / SM DB 25 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 160A, FP, MCCB Isolator - 1 No. 160A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 5 Nos.

1

-

-

... More
AHU PANEL / SM DB 26 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 3 Nos.

1

-

-

... More
AHU PANEL / SM DB 27 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings:16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 5 Nos.

1

-

-

... More
AHU PANEL / SM DB 28 Fabrication, supply, erection, testing and commissioning of cubicle type as per IEC 61439 and internal arc test as per IEC 61641, dust and vermin proof, floor/wall mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as required. All opening parts of the panel shall be sealable. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency,Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 16-63A, 16kA, TP+NL, Thermal Magnetic release MCCB - 4 Nos.

1

-

-

... More
Supplying and fixing FP sheet steel enclosure on surface/ recess along with 25/32/40amps 415 volts C curve FP MCB complete with connections, testing and commissioning etc. as required.

191

-

-

... More
Lockable off push button near pumps & CT.

19

-

-

... More
Remote ON/OFF Push button station with indication for AHUs

2

-

-

... More
SITC of Control box &DIGITAL DISPLAY PANEL inside the Operation theater with indication lamp, ON/OFF of AHU control, thermostat control of OT, cooling & heating mode, humidity control etc. Digital display of RH/TEMPERATURE, pressure (including pressure sensor & necessary control), wiring from AHU to unit etc. as per dwg / picture attached

6

-

-

... More
Sub head: CABLES AND TERMINATIONS

-

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 3.5cx150sq.mm Al Cable

72

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 3cx35sq.mm Al Cable

776

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 3cx16sq.mm Al Cable

1080

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 4cx10sq.mm Al Cable

8250

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 3 core x 1.5 sq mm copper Armoured Control cable

550

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 3 core x 1.5 sq mm shielded Armoured cu cable

240

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 2 core x 1.5sqmm copper Armoured Control cable

400

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 6 core x1.5 sq mm copper Armoured Control cable

300

-

-

... More
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

4

-

-

... More
9.1.10 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 35 sq. mm (28mm)

24

-

-

... More
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

24

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

496

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 3C X 1.5 sq. mm"

42

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 2C X 1.5 sq. mm

36

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 6C X 1.5 sq. mm

80

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

11596

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

72

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

10400

-

-

... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using necessary clamps duly painted or heavy duty spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required and as directed by engineer in charge 25 x3 mm copper strip

280

-

-

... More
90.16.3.12 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 6 mm copper strip

60

-

-

... More
Sub head: BUILDING MANAGEMENT SYSTEM

-

-

-

... More
Central core Computer - PC (Intel i7 Processor), 8 GB RAM, 2 GB Graphics card, DVD Writer, 22 LED monitor, 1 TB HDD, Microsoft mouse, Keyboards, 2 serial, 1 parallel port/KB, Windows 8 operating system, antivirus software

1

-

-

... More
A4 Colour Laser printer

1

-

-

... More
System Controller to interface field level controllers to IBMS Workstation . Supply, Installation, Testing and Commissioning of Building Management System Graphic User Interface software with 3 user client license, user groups, user profiles and scopes, alarm handling, scheduling, trending, reporting engine, database system, system activity log, historical data management, real time zoom enabled vector graphics, system backup and restore, HTML based documentation and help, SMS/Email facility complete in all respects as per tender specification. Graphical Software complete to cater to hardware points as specified in the Data Point Summary as well as Third Party Software Integrated Systems. Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Chiller System - 5 Chiller (50 points/chiller)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Secondary Pumps System (10 Points/Pump)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Variable Frequency Drives for AHUs (10 Points per VFD)

1

-

-

... More
Sub head: CONTROL FOR CHILLER SYSTEM

-

-

-

... More
Networkable DDC Controllers as per Data Point Summary (1- 5) with enclosure with all necessary wiring and accessories

1

-

-

... More
Immersion Type Temperature Sensor

4

-

-

... More
Outside Air Temperature &RH Sensor

1

-

-

... More
Level Switch for expansion tank ( 2 point) (depth of tank - 1 mtr.)

1

-

-

... More
Differential Pressure Switch

10

-

-

... More
Level Switch for cooling tower

5

-

-

... More
Sub head: CONTROL FOR AIR HANDLING UNITS: AHU 69 NOS

-

-

-

... More
Supply, Installation, testing &commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC

35

-

-

... More
Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter- Pre filter, fine filter as required

69

-

-

... More
Supply, Installation, testing &commsssioning of Return air Temperature Sensor

69

-

-

... More
Sub head: CONTROL FOR AIR HANDLING UNITS: AHU WITH HEATER: 4 NOS

-

-

-

... More
Supply, Installation, testing &commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC

2

-

-

... More
Supply, Installation, testing &commsssioning of Differential Pressure Switch across filter as required

4

-

-

... More
Supply, Installation, testing &commsssioning of Return air Temperature Sensor

4

-

-

... More
Supply, Installation, testing &commsssioning of RH Sensor Room type

4

-

-

... More
Sub head: CONTROL FOR AIR HANDLING UNITS: AHU WITH FINE FILTER: 7 NOS

-

-

-

... More
Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC

4

-

-

... More
Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter- Pre filter, fine filter as required

14

-

-

... More
Supply, Installation, testing & commsssioning of Return air Temperature Sensor

7

-

-

... More
Sub head: CONTROL FOR AIR HANDLING UNITS: AHU WITH FINE FILTER, HEATER: 20 NOS

-

-

-

... More
Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC

10

-

-

... More
Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter- Pre filter, fine filter as required.

40

-

-

... More
Supply, Installation, testing & commsssioning of Return air Temperature Sensor

20

-

-

... More
Supply, Installation, testing & commsssioning of RH Sensor Room type

20

-

-

... More
Sub head: CONTROL FOR AIR HANDLING UNITS: AHU FOR OT: 17 NOS

-

-

-

... More
Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC - For OT

17

-

-

... More
Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter- Pre filter, fine filter and Hepa filter as required

51

-

-

... More
Supply, Installation, testing & commsssioning of Return air Temperature Sensor

17

-

-

... More
Supply, Installation, testing & commsssioning of RH Sensor Room type

17

-

-

... More
Sub head: CONTROL FOR AIR HANDLING UNITS: AHU WITH HEAT RECOVERY WHEEL: 7 NOS

-

-

-

... More
Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories , consider 1 AHU / DDC.

7

-

-

... More
Supply, Installation, testing & commsssioning of Differential Pressure Switch across filter as required

7

-

-

... More
Supply, Installation, testing & commsssioning of Return air Temperature Sensor

7

-

-

... More
Supply, Installation, testing & commsssioning of RH Sensor Room type

7

-

-

... More
Sub head: CABLING WORKS

-

-

-

... More
SITC of Flexible Bare Copper Conductor, PVC Insulated,Cross Laid Up, Overall Aluminium Mylar Tape Shielded along with ATC Drain Wire PVC Outer Sheath BMS Cables - 2 Core 1.0 sq.mm. shielded FRLS Cable

7500

-

-

... More
SITC of Flexible Bare Copper Conductor, PVC Insulated,Cross Laid Up, Overall Aluminium Mylar Tape Shielded along with ATC Drain Wire PVC Outer Sheath BMS Cables - 4 Core 1.0 sq.mm. shielded FRLS cable

6800

-

-

... More
SITC of Flexible Bare Copper Conductor, PVC Insulated,Cross Laid Up, Overall Aluminium Mylar Tape Shielded along with ATC Drain Wire PVC Outer Sheath BMS Cables - 8 Core 1.0 sq.mm. shielded FRLS cable

11500

-

-

... More
SITC of Communication Cabling - 2 Core 1.5 sq.mm. shielded FRLS armoured cable or CAT5E armoured cable

2250

-

-

... More
SITC of Power Cable - 3c x 2.5 Sq.mm Cu Armoured Cable

3500

-

-

... More
MEDICAL GAS PIPELINE SYSTEM (MGPS)

-

-

-

... More
SITC of Oxygen Manifold - 2 banks x 24 cylinders, as per technical specifications

1

-

-

... More
SITC of Fully Automatic Oxygen Control Panel with minimum flow rate of 2000 LPM, BMS compatible; as per technical specifications

1

-

-

... More
SITC of Emergency Oxygen Manifold - 2 banks x 10 cylinders, as per technical specifications

1

-

-

... More
SITC of Nitrous Oxide Manifold - 2 banks x 2 cylinders, as per technical specifications

1

-

-

... More
SITC of Fully automatic Gas Control Panel for Nitrous Oxide with a minimum flow rate of 500 LPM, BMS compatible; as per technical specifications

1

-

-

... More
SITC of Nitrous Oxide Manifold (Emergency) - 1 bank x 2 cylinders, as per technical specifications

1

-

-

... More
SITC of Carbon Dioxide Manifold - 2 banks x 1 cylinders, as per technical specifications

1

-

-

... More
SITC of Fully automatic Gas Control Panel for Carbon Di Oxide with minimum flow rate of 300 LPM as per technical specifications

1

-

-

... More
SITC of Carbon Dioxide Manifold (Emergency) - 1 bank x 1cylinders, as per technical specifications

1

-

-

... More
SITC of Vacuum plant complete with 3 rotary vane type vacuum pumps, each vacuum pump should have minimum free air aspirated of 3000 LPM at 450 mmHg, 1 vacuum receiver, secretion trap, bacteria double filter, control panel, ball valves etc. ( ISO 10524-2, ISO 7396-1:2016/ISO, 7396-2/HTM02-01). 2000 Ltr 1 Vacuum receiver Tank.

1

-

-

... More
SITC of Compressed air plant complete with - 3 screw compressors, compressor should have minimum free air delivery of 3000 LPM and 1 screw compressor should have minimum free air delivery of 3000 LPM, 2 air receiver, medical air duplex drier system (heatless type) with air purification system to ensure medical air quality as per European Pharmacopeia, pressure reducing station, control panel, automatic drain valves, ball valves etc. and as per technical specifications. 1 air receiver Tank capacity 2000 Ltr

1

-

-

... More
SITC of Electrical Panel for Air Compressor &; Vacuum Pump

1

-

-

... More
SITC of Master Plant Alarm Panel (post source), as per technical specifications

1

-

-

... More
SITU of AVSU &Alarm systems - 6 Services 1 O2, 1M air, 1 N2O, 1 S air, 1 CO2 ; 1 Vac

9

-

-

... More
SITU of AVSU & Alarm systems - 4 Services 1 O2,1 N20, 1 M Air and 1 Vac

24

-

-

... More
SITU of AVSU & Alarm systems - 3 Services 1 O2,1 M Air and 1 Vac

5

-

-

... More
SITU of AVSU & Alarm systems - 2 Services 1 O2 and 1 Vac

23

-

-

... More
SITC - Ball Valves - 15mm;

17

-

-

... More
SITC - Ball Valves - 22mm

17

-

-

... More
SITC - Ball Valves - 28mm

32

-

-

... More
SITC - Ball Valves - 35mm

8

-

-

... More
SITC - Ball Valves - 42mm

5

-

-

... More
SITC - Ball Valves - 54mm

2

-

-

... More
SITC - Ball Valves - 76mm

1

-

-

... More
SITC - Ball Valves - 108mm

1

-

-

... More
SITC of Terminal Unit - O2

593

-

-

... More
SITC of Terminal Unit - N2O

15

-

-

... More
SITC of Terminal Unit - Air

167

-

-

... More
SITC of Terminal Unit - Air 7 bar

3

-

-

... More
SITC of Terminal Unit - VAC

593

-

-

... More
SITC of Terminal Unit - CO2;

1

-

-

... More
SITC of Matching Probe - O2

593

-

-

... More
SITC of Matching Probe - N2O

15

-

-

... More
SITC of Matching Probe - Air

167

-

-

... More
SITC of Matching Probe - Air 7 bar

3

-

-

... More
SITC of Matching Probe - VAC

593

-

-

... More
SITC of Matching Probe - CO2

1

-

-

... More
SITC of Copper pipe - per mtr. - 12mm

3014

-

-

... More
SITC of Copper pipe - per mtr. - 15mm

5330

-

-

... More
SITC of Copper pipe - per mtr. - 22mm

6129

-

-

... More
SITC of Copper pipe - per mtr. - 28mm

1525

-

-

... More
SITC of Copper pipe - per mtr. - 35mm;

562

-

-

... More
SITC of Copper pipe - per mtr. - 42mm

74

-

-

... More
SITC of Copper pipe - per mtr. - 54mm

187

-

-

... More
SITC of Copper pipe - per mtr. - 76mm

1

-

-

... More
SITC of Copper pipe - per mtr. - 108mm

94

-

-

... More
Oxygen Flowmeters with humidifier bottle

511

-

-

... More
SITC of Ward Vacuum Units

500

-

-

... More
SITC of Theatre Vacuum Units ;

11

-

-

... More
SITC of Bed Head Units - 1000 mm as per technical specificaitons.

244

-

-

... More
SITC of Bed Head Units - 1200 mm as per technical specificaitons

35

-

-

... More
SITC of Bed Head Units - 1500 mm as per technical specificaitons.

51

-

-

... More
SITC of Bed head Panels as per technical specifications.

125

-

-

... More
SITC of Rigid Pendent of column length 1000mm for ICU as per technical specifications.

44

-

-

... More
PNEUMATIC TUBE SYSTEM (PTS)

-

-

-

... More
Supply, Installation, testing and commissioning of PTS control units and sub components,control Softwares and Licenses for 3 zone system and RFID as per technical specifications. - Imported.

1

-

-

... More
Supply, Installation, testing and commissioning of PTS control Computer and sub components for 3 zone system as per technical specifications.

1

-

-

... More
Supply, Installation, testing and commissioning of Gery color PTS Distribution tube OD 110 mm as per technical specifications (also meeting DIN 6660 / 6661 / 8061 / 8062 - Imported )

900

-

-

... More
Supply, Installation, testing and commissioning of PVC Grey colour 90 degree Bend OD 110 mm with 2.3 mm thickness, , as per technical specifications (also meeting DIN 6660 / 6661 / 8061 / 8062- Imported )

145

-

-

... More
Supply, Installation, testing and commissioning of PVC Transparent Straight tube OD 110 mm with 2.3 mm thickness, 5000mm length as per technical specifications (also meeting DIN 6660 / 6661 / 8061 / 8062 - Imported )

30

-

-

... More
Supply, Installation, testing and commissioning of PVC Transparent 90 degree Bend OD 110 mm with 2.3 mm thickness, as per technical specifications (also meeting DIN 6660 / 6661 / 8061 / 8062 - Imported )

25

-

-

... More
Supply, Installation, testing and commissioning of DC power supply units, Control Cable Data-Com-Power Composite, Cable tie and sub components for system power distribution - Imported.

1

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled Intermediate / Pass through stations 110 mm with optical sensors for carrier tracking as per technical specifications - Imported

18

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled End stations 110 mm with RFID Transponder readers and optical sensors as per technical specifications. - Imported

1

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled End stations 110 mm with optical sensors as per technical specifications. - Imported

4

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled Multi Sending Lab stations 110 mm with RFID Transponder readers and optical sensors as per technical specifications. - Imported

1

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled LAB Receiving stations 110 mm with optical sensors, Carier receiving rail and Rail Extension, as per technical specifications. - Imported

1

-

-

... More
Supply, Installation, testing and commissioning of PTS 110 mm Swivel Caps Carriers with 2 RFID tags as per technical specifications. - Imported

96

-

-

... More
Supply, Installation, testing and commissioning PTS 3 way/4 way Diverters 110 mm as per technical specifications.

6

-

-

... More
Supply, Installation, testing and commissioning PTS transfer diverters 3 way/4 way Diverters 110 mm as per technical specifications.

6

-

-

... More
Supply, Installation, testing and commissioning of PTS 3-Phase Blower unit including Starter unit, Air Reversing unit and sub components for 110 mm each line as per technical specifications. Imported

3

-

-

... More
LIFT WORKS

-

-

-

... More
26 Passenger cum Bed Lifts LIFT-2,3,4,5,6,7,16:Design, manufacture, supply, installation at site, testing, commissioning and maintain (during guarantee period of 36 months from the date of commissioning) Passenger cum Bed Lift to carry 26 (Twenty Six) persons capacity of load 1768 Kgs with a minimum speed of 1.5 metre per second as per the detailed specification attached including all necessary safety features and in accordance with the particulars of lift service requirement and technical specifications etc. complete.09 Stops and 09 openings.(Shaft Size available - 3500 mmx 2500 mm)Note :The rate shall include obtaining necessary initial and final approval from Kerala State electrical Inspectorate for lift installation and operation before handing over the entire lift installation.

7

-

-

... More
LIFT-8,9:Design, manufacture, supply, installation at site, testing, commissioning and maintain (during guarantee period of 36 months from the date of commissioning) Passenger cum Bed Lift to carry 26 (Twenty Six) persons capacity of load 1768 Kgs with a minimum speed of 1.5 metre per second as per the detailed specification attached including all necessary safety features and in accordance with theparticulars of lift service requirement and technical specifications etc. complete.8 Stops and 8 openings.Shaft Size available - 3500 mm x 2500 mm)Note :The rate shall include obtaining necessary initial and final approval from Kerala State electrical Inspectorate for lift installation and operation before handing over the entire lift installation.

2

-

-

... More
Goods Cum Bed Lift LIFT-1:Design, manufacture, supply, installation at site, testing, Commissioning and maintain (during guarantee period of 36 months from the date of commissioning) Goods cum Bed Lift of 2T capacity with a minimum speed of 1.0 metre per second and as per the detailed specification attached including all necessary safety features and in accordance with the particulars of lift service requirement and technical specifications etc. complete.9 Stops and 9 openings.(Shaft Size available - 3500 mmx 2500 mm)Note :The rate shall include obtaining necessary initial and final approval from Kerala State electrical Inspectorate for lift installation and operation before handing over the entire lift installation.

1

-

-

... More
LIFT-10;Design, manufacture, supply, installation at site, testing, Commissioning and maintain (during guarantee period of 36 months from the date of commissioning) Goods cum Bed Lift of 2T capacity with a minimum speed of 1.5 metre per second and as per the detailed specification attached including all necessary safety features and in accordance with the particulars of lift service requirement and technical specifications etc. complete.8 Stops and 8 openings.(Shaft Size available - 3500 mmx 2500 mm)Note :The rate shall include obtaining necessary initial and final approval from Kerala State electrical Inspectorate for lift installation and operation before handing over the entire lift installation.

1

-

-

... More
LIFT-11,12,13,14,15:Design, manufacture, supply, installation at site, testing, commissioning and maintain (during guarantee period of 36 months from the date of commissioning) Passenger cum Bed Lift to carry 13(Thirteen) persons capacity of load 884 Kgs with a minimum speed of 1.0 metre per second as per the detailed specification attached including all necessary safety features and in accordance with the particulars of lift service requirement and technical specifications etc. complete.9 Stops and 9 openings.(Shaft Size available - 2000 mmx 2500 mm)Note :The rate shall include obtaining necessary initial and final approval from Kerala State electrical Inspectorate for lift installation and operation before handing over the entire lift installation.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.