INKEL Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

INKEL Limited - INKEL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date5 Aug 2023
Closing Date16 Sep 2023
Tender Amount₹ 1,67,56,37,715 
Notes
Download

Costs

Summary

Development Of Medical College Thrissur Construction Of Super Speciality Block

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-35(Cement quantity -400kg/m3)of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.800 mm dia piles

280.5

-

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-35(Cement quantity -400kg/m3) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.700 mm dia piles

368.5

-

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-35(Cement quantity -400kg/m3) of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used.600 mm dia piles

330

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification &the direction of engineer -in-Charge.Single pile above 200tonne and upto 230 tonne capacity.Initial test (Test Load 2.5 times the Safe capacity)(For 900mm dia pile)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 200 tonne and upto 230 tonne capacity Routine test Routine test (Test Load 1.5 times the Safe capacity).(For 900mm dia pile)

2

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification &the direction of engineer -in-Charge.Single pile above 150tonne and upto 200 tonne capacity.Initial test (Test Load 2.5 times the Safe capacity)(For 800mm dia pile)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 150 tonne and upto 200 tonne capacity Routine test(Test Load 1.5 times the Safe capacity)(For 800mm dia pile)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submitt the design of loading platform for the approval of Engineer-in-charge.Initial test up to 110 tonne capacity(Test Load 2.5 times the Safe capacity)(For 600mm dia pile)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Routine test up to 110 tonne capacity(Test Load 1.5 times the Safe capacity)(For 600mm dia pile)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile of 263 tonne capacity Routine test.(Test Load 1.5 times the Safe Capacity) (For 1000mm dia pile)

5

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification &the direction of engineer -in-Charge.Single pile of 263 tonne capacity Initial test.(Test Load 2.5 times the Safe Capacity) (For 1000mm dia pile)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification &the direction of engineer -in-Charge.Single pile above 135 tonne and upto 150 tonne capacity Routine test(Test Load 1.5 times the Safe capacity) (For 700mm dia pile)

1

-

-

... More
Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Single pile above 135 tonne and upto 150 tonne capacity.Initial test(Test Load 2.5 times the Safe capacity) (For 700mm dia pile)

1

-

-

... More
Earth Work

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

10472.11

-

-

... More
2.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

7571.59

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

984.46

-

-

... More
2.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock

2297.07

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

16.81

-

-

... More
2.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock

2476.22

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

12675.89

-

-

... More
Extra for conveying and depositing surplus earth beyond 50m and upto 1Km including loading and unloading as directed by Engineer- in-Charge.

8400

-

-

... More
Conveying and depositing surplus earth for every additional 1Km lead and part thereof including loading and unloading as directed by Engineer- in-Charge.

14000

-

-

... More
Supplying and packing 20mm stone aggregate between the retaining wall and earth fill along the building perimeter including watering, ramming, consolidating and dressing complete including lead, lift, stacking, transportation etc. as directed by the Engineer in charge - for retaining wall

170.5

-

-

... More
Plain cement Concrete

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

837.37

-

-

... More
Reinforced cement concrete and Shuttering work

-

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design).All work upto plinth level

68.95

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design).All work above plinth level upto floor V level

999.32

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing<br>and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Min cement content is 340kg/cum and no payment shall be made for extra<br>cement).All work above plinth level upto floor V level

11098.01

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Min cement content is 350kg/cum and no payment shall be made for extra cement).All work above plinth level upto floor V level

849.19

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 350 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design).All work upto plinth level

3894.03

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:-Minimum Cement content is 360 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design.All work upto plinth level

150.33

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:-Minimum Cement content is 360 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design.All work above plinth level upto floor V level

1773.67

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

11399.34

-

-

... More
Providing and fixing at or near ground level precast cement concrete in slabs,kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)

2.62

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

4288.23

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

5278.71

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

33736.13

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

48481.36

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

19873.74

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

1703.93

-

-

... More
5.9.13 : Centering and shuttering including strutting, etc. and removal of form for:Vertical and horizontal fins individually for forming box louvers band, facias and eaves boards

3095.22

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

199.76

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

38213.01

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

694045.69

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

2824744.55

-

-

... More
Block Work

-

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

7311.86

-

-

... More
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

3.29

-

-

... More
50.6.2.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

110.5

-

-

... More
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

5717.44

-

-

... More
6.3.2 : Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With Modular bricks

181.35

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

243.41

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

270.62

-

-

... More
7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)

25.52

-

-

... More
Dry random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level.

133.81

-

-

... More
Joinery Works

-

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

12686.83

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

808.56

-

-

... More
Providing and supplying Single glazing of 6 mm thick monolithic toughened glass of approved colour and shade with SHGC= 0.27,U value 1.8 and VLT =36% etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass shall be measured in sqm

2684.52

-

-

... More
8.32 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

264.34

-

-

... More
Supply & Installation of Hindalco or equivalent section 85191. The Fins should be fixed at 200mm module based on the requirement to the suitable Installation frame of aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings .The maximum length of the fin shall be determined based on the wind load calculation and deflection.Powder coated aluminium (minimum thickness of powder coating 50 micron)

17951.2

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

19845.71

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

47277.75

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade II Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

1579.04

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

555.29

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

554

-

-

... More
21.11.2 : Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm

232

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

412

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

2138.6

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

800.7

-

-

... More
21.13 : Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

206

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

232

-

-

... More
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm

889

-

-

... More
9.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm

889

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

91

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

434

-

-

... More
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

412

-

-

... More
9.106.2 : Providing and fixing PTMT handles with necessary screws etc. complete.150x34x24 mm weighing not less than 26 gms

416

-

-

... More
9.108.2 : Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms

832

-

-

... More
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

824

-

-

... More
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm

954

-

-

... More
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

640

-

-

... More
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) locking arrangement for sliding windows including necessary screws and fittings of approved make as directed by Engineer-in-charge.

2242

-

-

... More
Providing and fixing roller for shutters of sliding aluminium windows with necessary screws etc.complete.As approved by Engineer-in-charge

8968

-

-

... More
Providing and fixing roller for Aluminium sliding door

172

-

-

... More
Providing and fixing in position frameless fixed glazing using 12mm toughened glass fitted with patch fittings of approved brand or manufacture as detailed in the draiwng of specified size including supplying and fixng necessary holdfats, screws for fixing cleats, toughened glass with all labour and materials complete as per drawings and as directed.

87.71

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated<br>astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.2000mmX2400mm

15

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated<br>astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1500mmX2400mm

38

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated<br>astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1200mmX2400mm

32

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single/Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of<br>2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened<br>special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 800mmX2100mm

4

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single/Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of<br>2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened<br>special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 1200mmX2100mm

4

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single/Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of<br>2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened<br>special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make :Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.1500mmX2400mm

4

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single/Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of<br>2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened<br>special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make:Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder<br>coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.2000mmx2400mm

2

-

-

... More
Providing and fixing pin headed glass in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): glass of 4.0 mm thickness

96.34

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with<br>cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 1000mmX2100mm

1

-

-

... More
Frosted film - Supply and installation of 3M make frosted film pattern throughout all the internal glass panels wherever required of approx. 1.5 m height as per the approved pattern.

1128.28

-

-

... More
Automatic 6.0 mtr std-Bi Parting Sliding door (TAM-PS-01) with accessories including : Automatic Track with operational kit Sensor-2, Glass Clamp-2(1 .5Mtr each),Floor guides,seals,Safety Beam

4

-

-

... More
9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

0.08

-

-

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately).Second class teak wood:35 mm thick shutters.

6.84

-

-

... More
9.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak wood

5.13

-

-

... More
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

12

-

-

... More
50.9.15.2 : Supplying and fixing 300 mm Aluminium aldrop

418

-

-

... More
9.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

2

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With toughned glass of 6mm thickness

485.28

-

-

... More
Steel work and Fire Doors

-

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

28365.48

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

4358.99

-

-

... More
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works

170.94

-

-

... More
13.48.2 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture

17.79

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

87029.73

-

-

... More
10.25.1 : Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

1934.8

-

-

... More
10.25.2 : Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

4225.2

-

-

... More
10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

77.7

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

18

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

10.5

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

26.64

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

12385.52

-

-

... More
Supply, installation, testing and commissioning of 750mmx2100mm shaft door having 2hr fire rating with 46mm thick Shutter and outer frame of size 100x57mm. Shutter should be manufactured from 0.8mm thick GI sheet sandwiching with Honey comb insulation material. The door frames are manufactured from 1.2mm thick GI sheet. The door frame and single leaf door should be finished with powder coating of 50micron approved shade. Fire doors are inclusive of ball bearing SS hinges, mortice shaft lock and SS flush handle of size 120x40mm etc.as per the direction of Engineer -in charge.

82

-

-

... More
Supply, installation, testing and commissioning of 600mmx1500mm shaft door having 2hr fire rating with 46mm thick Shutter and outer frame of size 100x57mm. Shutter should be manufactured from 0.8mm thick GI sheet sandwiching with Honey comb insulation material. The door frames are manufactured from 1.2mm thick GI sheet. The door frame and single leaf door should be finished with powder coating of 50micron approved shade. Fire doors are inclusive of ball bearing SS hinges, mortice shaft lock and SS flush handle of size 120x40mm etc.as per the direction of Engineer -in charge.

103

-

-

... More
Supply, installation, testing and commissioning of 900mmx1500mm shaft door having 2hr fire rating with 46mm thick Shutter and outer frame of size 100x57mm. Shutter should be manufactured from 0.8mm thick GI sheet sandwiching with Honey comb insulation material. The door frames are manufactured from 1.2mm thick GI sheet. The door frame and single leaf door should be finished with powder coating of 50micron approved shade. Fire doors are inclusive of ball bearing SS hinges, vision panel with 5mm thick toughned glass of size 450mmx750mm, mortice shaft lock and SS flush handle of size 120x40mm etc.as per the direction of Engineer -in charge

58

-

-

... More
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 1000mmx2100mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size<br>200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors

2

-

-

... More
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 2000mmx2400mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors

37

-

-

... More
Flooring and Waterproofing

-

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

25506.13

-

-

... More
Providing and laying anti skid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.<br>Size of Tile 600 x 600 mm.

2488.17

-

-

... More
11.48.2 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

2488.17

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

498.27

-

-

... More
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in dadoing over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), fixing with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 6mm thickness, joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

5727.8

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

17352.74

-

-

... More
Providing and fixing machine cut, mirror/ eggshell polished, Granite stone work for wall lining (veneer work) including dado, skirting, risers of steps, etc., in required design and pattern wherever require, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and fixing with chemical adhesive,including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-charge.a. 18mm thick Granite of any colour and shade

584.25

-

-

... More
Providing and laying Vitrified step tiles in single piece indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement &matching pigments etc. complete.

747.01

-

-

... More
Extra for using or fixing glazed/ Ceramic/ Vitrified wall tiles with cement based high polymer modified quick-set tile adhesive ( Water based) conforming to IS : 15477, in average 3 mm thickness.

17352.74

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

2379.97

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm

139.61

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

4509.64

-

-

... More
Grading roof for water proofing treatment with:12mm thick plastering in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and mixing with water proofing material in proportion recommended by the manufacturers

3637.04

-

-

... More
Surface Preparation: Existing concrete surface shall be made clean,dry,smooth and free of chemical contaminants.The surface shall be thoroughly cleaned by using hand operated grinders for removing the laitence and exposing the porosity in the concrete surface. Down Take Pipe Packing: The pipes to be fixed should be filled in order to provided a proper bond and the same to be aligned by the respective agency.The annular space around the Rainwater pipe shall be packed using Conbextra GP2 or equivalent, a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR or equivalent on the core surface fixing leak free form work as per manufacturer's specification. Coving:Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with Nitobond SBR or equivalent at dosage of 2Ltrs per50kg cement as per manufacturer's specification. Pressure Grouting at Leaking points: Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex100@225gms or equivalent mixed to 50kg bag of cement including joints packing using polymer modified mortar. Fixing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification. Providing and applying a single component pitch free polyurethane based coating using Fosroc Nito proof 600 or equivalent that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane. It is elastomeric,seamless waterproof membrane applied in 2coats to DFT 1.2mm thick having a elongation capacity of over 400%. Termination to bed one on wall extending the coating to min. 300mm height above the finished floor level and sealed inside the groove of 20mm wide x 10mm thick flushed with polymer modified mortar as per vendor recmmendation. Laying 200gsm non woven geo textile membrane over waterproofing coating with overlap sealed using synthetic rubber adhesive before providing screed concrete. The material shall comply to ASTMC836. Elongation (ASTMD412):400%,Specific gravity:1.4g/cc, Solid content:85%, Modulus@100% elongation (ASTMD412):0.62N/mm2;, Tear resistance (ASTMD624):15N,Water vapour transmission (ASTME96):0.6g/m2;/hr.,Water permeability@5bar: Nil, Shore A hardness (ASTM D2240) : 60.

3637.04

-

-

... More
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, odiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer in- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

2855.46

-

-

... More
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, odiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer in- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

598.84

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

2734.09

-

-

... More
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate

285.6

-

-

... More
11.5 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

3389.93

-

-

... More
13.52.2 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work

3389.93

-

-

... More
False ceiling works

-

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending

10451.69

-

-

... More
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T"of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.<br>GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm dip; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.

13429.24

-

-

... More
Aluminium Non perforated false ceiling - Providing & Fixing true horizontal level swing down suspended ceiling comprising of approved make Aluminum Clip in Swing Down with double pip self-leveling feature and special tabs to allow swing down of tile to enable plenum access with plain visual consisting of 600X600 mm clip in plain tiles of 0.7mm uniform thickness Aluminum with bevel edge in approved color precoated with primer coat at the rear side with Light Reflectance 60%.Tiles should have fire performance of Class A2-s1.d0 as per EN13501.The grade of aluminiumshall mandatorily be AA 3003. The AluminiumTile shall mandatorily be RoHS Compliant (Resistance of Hazardous Substance).Compliant certificate shall be provided on demand. The tile shall maintain uniform Thickness of 0.7mm across all areas of tiles with no deviation. The tile shall have paint thickness of 25 microns to enable better scratch resistance.The tile shall have the ability to combine the main light with extra illumination providing 77% light reflectance & enables to achieve light uniformity. The tile shall have g Ceiling Attenuation Class of 44db. It shall withstands upto 150 Scrub cycle using Scrubablity tester as per ASTM D 2486. The tile shall offer superior wash performance without compromising panel finish integrity using a washablity tester as per ASTM D 4828. Installation: To comprise 3000mm long C channels spaced at 1200mm centers securely fixed to the structural soffit by support clamp & approved hangers. The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm spring tee bars shall be spaced at 600mm centers in a direction perpendicular to the C-channels and shall be secured at every intersection with C channel using a tee bar hanger. Use T bar connector to splice two pieces of spring tee bars. Tiles should be clipped in between two spring tee bars from below. This is a downward installation. All full panels can be removed and reinstalled without movement up into the plenum area. Perimeter trims of approved color secured to walls at 450mm maximum centers. Cut tiles to be secured to the wall angles using a spring clamp. The installation shall be undertaken as per the manufacturer’s installation instructions and as directed by the Engineer-in-Charge.

2238.12

-

-

... More
Finishes

-

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

11836.41

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

121171.76

-

-

... More
Wall painting with acrylic emulsion paint(low VOC paint as per Griha norms V-2015) of approved brand and manufacture to give an even shade:Two or more coats on new work

94236.27

-

-

... More
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).

34832.39

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

58.3

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc.Excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size).

164.93

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

91152.06

-

-

... More
13.5.1 : 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1 Cement : 4 coarse sand)

974.32

-

-

... More
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

5130.05

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

86334.52

-

-

... More
Finishing walls with textured exterior paint (low VOC paint as per Griha norms V-2015) of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

2532.27

-

-

... More
Finishing walls with Acrylic Smooth exterior paint (low VOC paint as per Griha norms V-2015) of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

22790.41

-

-

... More
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

487.12

-

-

... More
60.6 : PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.

201.44

-

-

... More
12.63 : Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittnce tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strictly as per manufacture's specifications and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer - in- charge.

2704.26

-

-

... More
Finishing and Roofing

-

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

1403.25

-

-

... More
12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)

97.36

-

-

... More
12.7.1 : Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2

164.4

-

-

... More
Providing and fixing 160mm wide, 100mm depth, 3mm thick UPVC gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.

76.6

-

-

... More
Poly carbonate sheet roofing -Supply and installation of 2mm thick Poly-carbonate sheet roofing of approved make, embossed clear with UV protection coating/treatment with VLT=66% and weight not less than 2400gms/ sqm. It shall be fire retardant and confirming to IS 14443. the rate shall include aluminium leak proofing and fixing management system with EPDM rubber gaskets, silicone sealant etc. complete as required and as per the direction of engineer in charge

979.4

-

-

... More
External Works

-

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

7

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

9

-

-

... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

3

-

-

... More
2.33.4 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth

2

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

500

-

-

... More
19.35.1 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.

80

-

-

... More
19.35.2 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) ncluding testing of joints etc. complete.600 mm dia RCC pipes.

35

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

1039.88

-

-

... More
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

5199.34

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

46.82

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

109.2

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

10

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

10

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

30

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

50

-

-

... More
Site Clearance

-

-

-

... More
Clearing and grubbing land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and preservation of top organic soil not exceeding 200 mm in thickness In area of thorny jungle - By Mechanical Means

1.35

-

-

... More
11.9 : Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year

84

-

-

... More
Expansion Joint

-

-

-

... More
EXPANSION JOINT TREATMENT WORKS-CEILING: A)Providing, placing and fixing in position 150 mm wide and 100 mm thick PVC board of supreme make or Equivalent of 100 kg/cum density at all expansion joints and separation joints and wherever specified to the required sizes, shapes, etc., complete B)Protecting the expansion joint system with Aluminium sheet in a U shape fashion, extending the same up to 150 mm on both side vertically. (Both Horizontal &Vertical) Thickness of sheet is 2 mm.

478

-

-

... More
5.44.2 : Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self – centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge . (Material shall confirm to ASTM 6063).Floor Joint of 150 mm gap.

491.5

-

-

... More
5.45.2 : Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wal to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).Wall Joint of 150 mm gap.

1092

-

-

... More
5.46.2 : Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063.Roof Joint of 150 mm gap.

85.8

-

-

... More
Subhead 2 - Public Health Engineering System Sanitary Fixtures, Bath Fittings and Accessories

-

-

-

... More
Providing and fixing White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF (Adjusting up to 2/4 LPF) Dual Cistern, Overall size 660 x 375 x 760mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion / rawl sleeves, gasket etc. complete, and fixing to wall, as per manufacturer's instruction and to the approval of Engineer-in-charge. The Float Valve for Cistern shall be capable of withstand 5.0 Bar. Working Pressure.

289

-

-

... More
Providing and fixing sanitary fixtures for handicapped toilet including one number White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF (Adjusting up to 2/4 LPF) Dual Cistern, overall size 660 x 375 x 760mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion / rawl sleeves, gasket etc. complete, wash basin, one pair mounting brackets, one number elbow operated pillar cock 3.8 LPM @ 3 Bar and all other related fittings like waste coupling one number hinged rail 76 cm & 4 nos. of grab rails 60cm etc., designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge.

14

-

-

... More
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

16

-

-

... More
Providing and fixing White Virtuous China Urinal, of approved shape and size,with Integral P-Trap and with Integrated Electronic Flushing System with Passive and Extra Sensitive Infra-Red Sensor (Battery/AC Operated, as per final requirement), overall size: 610 x 390 x 370mm, with a Total Flushing Rate of 0.75 LPF, having pre & post flushing with water, (250 ml & 500 ml respectively),and with water inlet from back side including fixing at wall with suitable Brackets, all as per manufacturer's instruction and direction of Engineer-in-charge.

91

-

-

... More
8.10.2 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade

77

-

-

... More
Providing and fixing White Vitreous China Counter Top / Bottom Wash Basin, 400 x 550 mm or equal, including 32mm. CP Waste Coupling, C.P. Brass Chain with rubber plug, and fixing to counter with suitable fixtures, all as per manufacturer's instruction and the direction of Engineer-in-charge.

262

-

-

... More
Providing and fixing White Vitreous China Wall Hung Wash basin, 550 x 400 mm or equal, including 32mm. CP Waste Coupling, and fixing to wall with suitable fixtures, all as per manufacturer's instruction and the direction of Engineer-in-charge.

45

-

-

... More
Providing and fixing 15mm. CP Pillar Tap, Self Closing Type with Pre Set time 5 to 6 Sec, with a controlled flow rate of 2.5 LPM at 3 Bar.(overall dimensions:110 x 120 /150mm. or equal), complete with all necessary accessories for Wash Basins, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

307

-

-

... More
17.25.6 : Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:Surgeon type wash basin of 660x460 mm

56

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action Pillar Tap with extended lever handle, flow rate of 3.8 LPM at 3 Bar, complete with all necessary accessories for Wash Basins all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

56

-

-

... More
17.11.2 : Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm

47

-

-

... More
17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board 610x510 mm bowl depth 200 mm

48

-

-

... More
17.10.1.3 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board 510x1040 mm bowl depth 200 mm

3

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action, Wall Mounted type, Clinical Sink Tap with extended lever handle, flow rate of 3.8 LPM @ 3 Bar, complete with Wall Flange and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

51

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action, Wall Mounted type, Clinical Sink Mixer with extended lever handle, flow rate of 3.8 LPM @ 3 Bar, complete with Wall Flanges and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

47

-

-

... More
Providing and fixing CP Shower Set, Hot & cold CP aerator wall mixer unit of 6 LPM @3 Bar or less with long bend pipe for overhead shower with all accessories icluding Head Shower, Shower Arm, etc.,including all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

59

-

-

... More
Providing and fixing CP Shower Set, for Cold Water only, low flow rate of 6 LPM or less, Commercial Range, complete with Concealed Valve & Exposed Control Unit, Head Shower, Shower Arm, etc., including all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

37

-

-

... More
Providing and fixing CP Long Body Tap, both Cold & Hot Water Supply, with a controlled flow rate of 6 LPM @ 3 Bar, 15mm. nominal bore, 185mm. long with wall flanges and all other necessary accessories,all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

150

-

-

... More
Providing and fixing Health Faucet with a controlled flow rate of 3.8 LPM @ 3Bar, 15mm. CP Braided Hose, Hook and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

303

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

999

-

-

... More
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore

696

-

-

... More
Providing and Fixing ABS Body P-Trap with threaded union connections, flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge. For Wash Basin, 32mm Size.

363

-

-

... More
Providing and Fixing ABS Body P-Trap with threaded union connections, flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.For Sinks and Scrub, 40mm Size

98

-

-

... More
Providing and fixing at site in position Grab Bar up to 600mm complete.

305

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

96

-

-

... More
17.72 : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms

56

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

96

-

-

... More
17.34.1 : Providing and fixing toilet paper holder:C.P. brass

6

-

-

... More
Providing and fixing of C. P. Robe Hook, 60mm Dia. x 45mm High.

319

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

187

-

-

... More
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

30

-

-

... More
Providing and fixing cooler (hot, cold and normal water) with inbuild RO filter including cost and conveyance of all materials labour charges etc. complete, including necessary wall cutting / chasing and making good as required etc. complete, testing and commissioning to the satisfaction of Engineer in Charge as per direction of Engineer-In charge at all levels.

5

-

-

... More
Providing and fixing of Slop Hopper with Pressing valve 304G Stainless Steel, Conical flushing bowl with continues flushing rim having whirl effect, P / S trap for drainage, Health faucet Dimension : 24”L x24”W x 35”H"

20

-

-

... More
Integral Drainage

-

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).160mm OD

240

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site(For Soil & Waste pipes -Internal).110mm OD"

2430

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm),Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).75mm OD"

2630

-

-

... More
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall

834.75

-

-

... More
50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall

132

-

-

... More
50.18.9.14.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall

348

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

668

-

-

... More
50.18.8.5.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2

99

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of 4kg/cm2 (IS:4985)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends,Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Vent pipes -Internal).63mm OD"

518

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 160mm OD"

46.2

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 110mm OD"

982.8

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 75mm OD"

533.4

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 160mm OD"

1037.4

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 110mm OD

37.8

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type A (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm),Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Vent pipes -Internal). 75mm OD"

827.4

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe of 4kg/cm2 (IS:4985)) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete. 63 mm OD(4kg/cm2) "

46.2

-

-

... More
Deep Seal uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position Deep Seal (7”) uPVC Fabricated Multi Floor Trap, with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, Anchor fasteners etc. complete in all respects - 50/75 mm dia inlet/outlet (In Ceiling)

581

-

-

... More
uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost o cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken)

89

-

-

... More
Supplying, installing, testing & commissioning at site in position 110mm dia deep seal PVC P Trap with boss tee and access cap including all necessary fittings and supports complete

79

-

-

... More
Providing and Fixing C.P. brass or stainless steel (SS-304) Square Flat cut single piece Gratings size 125x125 mm. Gratings for 110mm. Floor Traps.

678

-

-

... More
Heavyduty stainless steel cover for Concealed Floor Trap for Urinal - Providing and Fixing 125x125mm dia Heavyduty stainless steel cover for Concealed Floor Trap ISI 304 Cover, for Urinal.

79

-

-

... More
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 110mm

18

-

-

... More
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 75mm

55

-

-

... More
17.35.1.3 : Providing and fixing soil, waste and vent pipes:100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

40

-

-

... More
17.38.1.3 : Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm diaHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

4

-

-

... More
17.39.1.3 : Providing and fixing plain bend of required degree.100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

4

-

-

... More
17.42.1.3 : Providing and fixing double equal plain junction of required degree.100x100x100x100 mmHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

1

-

-

... More
17.44.1.3 : Providing and fixing single equal plain junction of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

2

-

-

... More
17.49.1.3 : Providing and fixing double equal plain invert branch of required degree:100x100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

1

-

-

... More
17.50.1.3 : Providing and fixing single equal plain invert branch of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

1

-

-

... More
17.56.1.3 : Providing and fixing terminal guard:100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

1

-

-

... More
17.60.1.3 : Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outletHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

8

-

-

... More
17.57A.1.1 : Providing and fixing shielded coupling for Hubless centrifugally cast iron pipeSS 304 grade coupling with EPDM rubber gasket

36

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Dome Type with Cast Iron body,Aluminium Ring, Aluminium Dome, S.S. Screws etc. complete with Gratings, suitable for 110mm. of down pipes. 100mm dia. for 110mm. PVC Down Pipe

26

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Side Wall Parapet Type in Cast Iron body,Aluminium Gratings, S.S. Screws etc. complete with Gratings, all as per Technical Specifications. 100mm dia. for 110mm. PVC Down Pipe

11

-

-

... More
160mm uPVC for Rain Water Gutter with Leaf Guard - Supply, Installation, Testing and commissioning of 160mm uPVC Rain water gutter with Leaf Guard for Truss roof, including different types of fittings,required clamps and accessories. Gutters and fittings are specially designed to meet the requirements of all types of sloped roofs buildings. The system is provided with specially designed rubber gasket/seals to give totally leak proof joints to install with brackets and clamp complete

300

-

-

... More
Water Supply

-

-

-

... More
18.8.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes

265

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

3091

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

182

-

-

... More
18.7.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 15 mm nominal outer dia pipes

1556.2

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 20 mm nominal outer dia pipes

3949.4

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 25 mm nominal outer dia pipes

566.8

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

314

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 40 mm nominal outer dia pipes

48

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 50 mm nominal outer dia pipes

829

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes.

20

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 20 mm nominal outer dia. Pipes.

445.2

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing, Anchor fastners (8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 25 mm nominal outer dia. Pipes.

472.8

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 32 mm nominal outer dia. Pipes

303.2

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 40 mm nominal outer dia. Pipes.

250.8

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings,fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 50 mm nominal outer dia. Pipes.

341.8

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes

456

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 80 mm nominal outer dia. Pipes.

31.8

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 100 mm nominal outer dia. Pipes.

822

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 150 mm nominal outer dia. Pipes.

15

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 80 mm nominal outer dia. Pipes.

71.2

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 40 mm nominal outer dia. Pipes.

71.2

-

-

... More
18.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

489

-

-

... More
18.18.3 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore

65

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

48

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

19

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

8

-

-

... More
Supply, fix at site in Supply, fix at site in position, test and commission, Brass Ball Valves to IS: 554 / BS:21 / ISO: 7,PN;25,with Screwed Female Ends complete with all necessary accessories. 40mm. (11/2")

1

-

-

... More
Supply, fix at site in position, test and commission, Brass Ball Valves to IS: 554 / BS:21 / ISO: 7,PN;25,with Screwed Female Ends complete with all necessary accessories. 50mm. (2")

8

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories. 15mm. (1/2")

79

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories. 20mm. (3/4")

72

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories. 25mm. (1")

6

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN;20, Screwed Female ends, complete with all necessary accessories. 32mm. (11/4")

10

-

-

... More
18.19.3.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreVertical

4

-

-

... More
18.19.4.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreVertical

2

-

-

... More
18.19.5.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreVertical

4

-

-

... More
18.19.6.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreVertical

16

-

-

... More
Providing and fixing Brass non-return valve of approved quality (screwed end):100 mm nominal bore Vertical

4

-

-

... More
Brass Automatic Air Release Valves - Providing, Fixing, testing and commissioning at site in positions Brass Automatic Air Release Valves, of approved quality and make on the top of the vertical water supply pipes as per specification and drawing - 3/4"(20mm) dia

37

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN10) of approved make with PP float & nipple with brass threaded in-sert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 65mm dia (2 1/2”)

2

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN10) of approved make with PP float & nipple with brass threaded in-sert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 50mm dia (2”)

1

-

-

... More
SS ball valve 15mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - ½” (15mm) dia

28

-

-

... More
SS ball valve 20mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - ¾” (20mm) dia

30

-

-

... More
SS ball valve 25mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1” (25mm) dia

4

-

-

... More
SS ball valve 32mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1¼”(32mm) dia

1

-

-

... More
SS ball valve 40mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1½”(40mm) dia

1

-

-

... More
SS ball valve 50mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 2”(50mm) dia

4

-

-

... More
18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore

1

-

-

... More
18.17.6 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore

1

-

-

... More
"Providing and fixing C.I. Sluice Valve, PN-16, with IS: 14846 Mark, with required flanges, rubber in sertions, bolts, nuts, Washers etc. complete. 80mm PN-16

1

-

-

... More
"Providing and fixing C.I. Sluice Valve, PN-10, with IS: 14846 Mark, with required flanges, rubber in sertions, bolts, nuts, Washers etc. complete. 300mm PN-10

2

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect.80 mm dia

1

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect.100 mm dia

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum. Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10 meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection. Water meter 50mm

2

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum. Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection. Water meter 65mm

3

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum. Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection. Water meter 80mm

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum. Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection.Water meter 100mm

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10 micro siemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum.Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10 meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection. Water meter 150mm

2

-

-

... More
Supplying, fixing testing and commissioning Stainless steel Butterfly Valve Grade 316(CF8M), PN-16,Wafer type, Lever Operated, Confirming to BIS: 5155 / IS 13095 / API 609, with required flanges, nuts,bolts etc., complete 65 mm dia

2

-

-

... More
CI Y Strainer 2” (50mm) dia -Supply,Installation,Testing and Commisioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

2

-

-

... More
CI Y Strainer 2 ½” (65mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects.

3

-

-

... More
CI Y Strainer 3” (80mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
CI Y Strainer 4” (100mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
CI Y Strainer 6” (150mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects

2

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 100 mm. dia. (4") pipe.

415

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 80 mm. dia. (3") pipe.

15

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 65 mm. dia. (2 1/2") pipe.

457

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 50 mm. dia. (2") pipe.

580

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 40 mm. dia. (1 1/2") pipe.

16

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 32 mm. dia. (1 1/4") pipe.

11

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 25 mm. dia. (1") pipe.

39

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 20 mm. dia. (3/4") pipe.

250

-

-

... More
"Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 65mm. (2 1/2") pipe."

10

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 50mm. (2") pipe."

406

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 32mm. (1 1/4") pipe

105

-

-

... More
"Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 25mm. (1") pipe.

125

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping) For 20mm. (3/4") pipe."

1154.4

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 15mm. (1/2") pipe."

1096.4

-

-

... More
External Sewerage and Storm Water Drain

-

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers,sockets,connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation) 200mm OD

90

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients,PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete (excluding excavation) 160mm OD

600

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete (excluding excavation) 110mm OD

240

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying,Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation) 75mm OD

100

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete(excluding excavation) 315mm OD

25

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete (excluding excavation) 250mm OD

50

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying,Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete(excluding excavation) 200mm OD

100

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete (excluding excavation) 160mm OD

150

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete(excluding excavation) 110mm OD

84

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings. This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 80 mm nominal outer dia Pipes

60

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings. This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 40 mm nominal outer dia Pipes

100

-

-

... More
Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching,refilling & testing of joints complete as per direction of Engineer in Charge. 90 mm dia 10 kgf/cm2

1125

-

-

... More
Supply,installation, testing and commissioning of stainless steel Bar Screen (opening 50mm) suitable for screen mesh of size 500mmx500mm removable type including all material charges, labour transportation,loading unloading etc. Complete as per the direction of Engineer in charge.

12

-

-

... More
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With Sewer bricks conforming to IS: 4885

36

-

-

... More
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design

350

-

-

... More
Extra for excavating trenches for pipes above 80mm. But not exceeding 300mm.. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre).Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

100

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

1439

-

-

... More
18.41.1A : Providing and filling sand of grading zone V or coarser grade, all - round the G.I. pipes in external workSub analysis item for sand filling component

115

-

-

... More
4.1.10 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

122

-

-

... More
Supply, installation, testing and commissioning at site Rain Water Filter Unit, Bag Filtration System, suitable for a Flow Rate of 135M³/ Hr, with Filter Bags and Accessories in FRP Fabricated Tank, 1500mm. dia. x 1500mm.deep. Wall thickness 10mm. all as per Technical Specifications. The price is inclusive of connected Pipe Work. Civil work is to be counted separately

1

-

-

... More
Civil Work for RCC Manhole

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

629.43

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

595.13

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

270.25

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

25.99

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

165.29

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

19796.96

-

-

... More
Providing and fixing at or near ground level precast cement concrete in slabs,kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)

27.42

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

192.92

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

201.56

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

1218.1

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

1218.1

-

-

... More
10.25.1 :Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

5596.1

-

-

... More
Supplying, Installation, Testing and Commissioning of the Ductile Iron Circular Manhole cover with Frame(Double seal with EPDM Gasket and SS Bolting arrangement lifting key holes & load tested as per IS:1726 & BS EN:124.600mm Dia. (Medium duty) (Minimum weight 68Kg).

14

-

-

... More
Supplying, Installation, Testing and Commissioning of the Ductile Iron Rectangular Manhole cover with Frame (Double seal with EPDM Gasket and SS Bolting arrangement lifting key holes & load tested as per IS:1726 & BS EN:124. 600x 900. (Heavy duty) (Minimum weight 135Kg).

15

-

-

... More
Supplying, Installation, Testing and Commissioning of the Ductile Iron Circular Manhole cover with Frame (Double seal with EPDM Gasket and SS Bolting arrangement lifting key holes & load tested as per IS:1726 & BS EN:124. 600mm Dia. (Heavy duty) (Minimum weight 75Kg).

38

-

-

... More
Miscellaneous Items

-

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick-For 160mm dia. pipe

4

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - For 110mm dia pipe.

1031

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick- For 75mm dia pipe.

2

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - For 63mm dia pipe.

2

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick- For 50mm dia pipe

552

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - For 40mm dia pipe.

32

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick - for 32mm dia pipe

319

-

-

... More
600 X 600 mm (24" X 24") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Light Duty (5 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124. For OH Water tank

6

-

-

... More
"600 X 900 mm (24"" X 36"") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover and frame Heavy Duty (25 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124. For UG Sump"

2

-

-

... More
600 X 600 mm (24"" X 24"") inside using self pigmented type double seal (Air & Water tight) FRP manhole cover with frame Heavy Duty (25 MT) with closed bottom (not thru & thru) lifting key holes & load tested as per IS:1726 & BS EN:124 For UG Sump

10

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 150mm (6")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -150mm(6") uPVC Astm Sch 80 Puddle flange

3

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 100mm (4")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -100mm(4") uPVC Astm Sch 80 Puddle flange

12

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 80mm (3")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 80mm(3") uPVC Astm Sch 80 Puddle flange

9

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 65mm (2½") uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -65mm (2½") uPVC Astm Sch 80 Puddle flange

9

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 50mm (2")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 50mm(2")uPVC Astm Sch 80 Puddle flange

6

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 40mm (1½")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 40mm (1½")uPVC Astm Sch 80 Puddle flange

1

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 32mm (1¼")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -32mm 1¼"uPVC Astm Sch 80 Puddle flange

1

-

-

... More
Plumbing Pumps and Tank

-

-

-

... More
Supply, Installation, Testing and Commissioning 2 nos, Vertical multistage pump set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 5.4 lps @ 50mtr head, Head range 40 to 60 mtrs, ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection with Wall mounting Microprocessor based common control Panel to operate the pump set as ( 1Working +1Standby ) Star Delta, having features of automatic pump change over in every Start/Stop, Dry run,Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function with sufficient length cable, Digital display, Pressure gauge - 2nos, Float Switches, Auto/Manuel Operation.

1

-

-

... More
Supply, Installation, Testing and Commissioning 2 nos, Vertical multistage pump set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 1.3 lps @ 54mtr head, Head range 44 to 64 mtrs, ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection with Wall mounting Microprocessor based common control Panel to operate the pump set as ( 1Working +1Standby ) Star Delta, having features of automatic pump change over in every Start/Stop, Dry run,Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function with sufficient length cable, Digital display, Pressure gauge - 2nos, Float Switches, Auto/Manuel Operation. (Negative suction minimum 3mtr minimum required)

1

-

-

... More
Supply, installation, testing and commissioning of SEWAGE & WASTEWATER TRANSFER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long-Lasting cutter Pumps with High Efficiency Electrical Motors, One Working + Cyclically Stand by pump with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete. Required upto 35mm size solid handling. Impeller Material: Cast Iron FG 260.Shaft Material: S.S AISI 410.Capacity: 7.10LPS @ 10Mtr. Head, Head range 5 to 15 mtr, 3Ph, Complete Set.

2

-

-

... More
Supply, installation, testing and commissioning of SEWAGE & WASTEWATER TRANSFER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long-Lasting cutter Pumps with High Efficiency Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Autoand Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet /Base,Stainless Steel (Grade:304) Lifting Chains etc, complete. Required upto 35mm size solid handling. Impeller Material: Cast Iron FG 260 Shaft Material: S.S AISI 410 Capacity: 6LPS @ 10Mtr. Head, Head range 5 to 15 mtr, 3Ph, Complete Set."

2

-

-

... More
Supply, installation, testing and commissioning of SEWAGE & WASTEWATER TRANSFER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long-Lasting cutter Pumps with High Efficiency Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete. Required upto 35mm size solid handling. Impeller Material: Cast Iron FG 260.Shaft Material: S.S AISI 410.Capacity: 3LPS @ 10Mtr. Head, Head range 5 to 15 mtr,3Ph, Complete Set."

2

-

-

... More
FILTER FEED PUMP SET. Supply, Testing and Commission Filter Feed Pump Set, Submersible Type for Pumping Raw Water to Water Treatment Plant, 2 Pump System with One Working + 1 One Cyclically Stand by Pumps, each Pump of Capacity: 25M³/Hr. @ 15Mtr. Head, Head range 3 to 18.8 mtr,having CI Casing, SS Shafts, CF8 Impeller with 3Ph, complete with Microprocessor Based Control Panel,for Auto and Cyclic Operation, with all Protection (Digital display, Low &high voltage protection, dry run, phase reversal, pump over load, etc.), Level Sensors / Float Switches in Treated Water & Raw Water Tanks and Control Cabling / Wiring between Level Sensors / Float Switches and Control Panel, Delivery Manifold, Isolating Valves, Non Return valves, Pressure Gauge, Fittings, Stainless Steel (Grade:304) Lifting Chains, Accessories etc. all as per Technical Specifications. The Control Panel shall be capable operating the pumps (starts and stops) by sensing the level difference in water in the Treated Water Tank. Also; capable of ‘not starting or stopping the running pumps', when the water in the underground Raw Water Tank goes below the pre-set minimum level. The Pumps to be installed in the underground Raw Water Tank/Rain water Tank and Common Control Panel in the Pump Room, approx. 50 Mtr. away from Raw Water Tank. The Underground Power Cabling between Pumps and Control Panel and Control Cabling between Control Panel & Level Sensor / Float Switch, in the Underground Raw Water Tank, shall be measured as a part of Electrical Work. The Quoted Price for the Pump Set shall be inclusive of all above requirement, necessary Level Sensors / Float Switches, Power Cabling, Control Cabling etc, except what measured as a part of Electrical Work, as detailed above."

1

-

-

... More
Providing, Fixing, Testing and Commission Submersible Type Dewatering Pump Set,complete set with 1 working + 1 Standby Submersible non- clog pump, Solids handling: 10mm, and with Common Control Panel for auto and cyclic operation. Capacity 10lps at 12Mtrs. head each, Three Phase, with float switches/level sensors etc. necessary control valves, fittings and accessories, for discharging rain water from collection pits in basement floor, to lower strata. The price shall inclusive of all connected electrical work as detailed in the technical specification.

1

-

-

... More
"Supplying, Installing, Testing & Commissioning at site hot water recirculation pump with suitable pressure switch, dry run protection & The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication(Modbus). Type : Thermostatic Controlled. Horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The shaft,impellers and chambers are made of stainless steel. The inlet and discharge parts are made of cast iron.It’s supporting up to 95 degree Celsius temperature, digital control panel with Time and Temperature settings facility. Flow for pump in LPS : 5 Head in mtr : 7 MOC : SS 304 Impeller"

1

-

-

... More
Supply, installation, testing & commissioning of Solar assisted Heat pump, insulated pressurised SS storage tank, hot water expansion vessel, insulated piping between the system, valves & accessories required to complete the system in position with the following specification. 10,000 LPD, consisting of Solar Hot Water Panels of Aggregate Capacity: 5,000 LPD (50% of the total requirement), 58 Deg C required Insulated Hot Water Storage Tank suitable for 6 bar pressure SS 316 - 5nos, 2000 Litre - Horizontal. COP of Heat pump 4.Circulation Pump between heat pump and storage tank, including control panel.Plumbing work Between storage tank and heat pump CPVC Pipe with suitable CPVC Fittings. Suitable Brass Fittings like NRV, Y Strainer, Air Vent, MTA, FTA, Flow Switches, Pipeline Insulation.Electrical Work From Pump panel to heat pump 6 Square MM 4 core cable, 1.5 Square MM 3 core cable, 2.5 Square MM cable, Communication cable, 3 x 9Amps 3MP Contactors Coil Operated, PVC conduits for cables with suitable fittings etc., complete.

1

-

-

... More
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

-

-

... More
Water Treatment Plant

-

-

-

... More
Supply, Installation, testing and commissioning Water Pre-Treatment Plant Capacity: 25M3 /Hr, for continuous operation of 10 Hr, complete with High Pressure Sand Filter, Activated Carbon Filter, with Multiport valves, Chemical Dosing etc as per final requirement, connected Pipe Work etc, all as per Technical Specifications. Filter Feed Pumps shall be measured separately.

1

-

-

... More
External Irrigation and Pumping

-

-

-

... More
Supply, Installation, Testing and Commissioning 2 nos, Vertical multistage Centrifugal Pump Set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 7.22lps @ 50mtr head, Head range 40 to 60 mtrs, ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection with Wall mounting Microprocessor based common control Panel to operate the pump set as ( 1Working + 1Standby ) Star Delta, having features of automatic pump change over in every Start/Stop, Dry run,Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function with sufficient length cable, Digital display, Pressure gauge - 2nos, Float Switches, Auto/Manuel Operation.(Negative suction 3mtr minimum required)

1

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 65 mm nominal outer dia Pipes"

800

-

-

... More
18.19.5.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal bore Vertical

2

-

-

... More
Supplying,fixing,testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Butterfly Valve (Manual) with CI body SS disc nitrile sheet & O -ring & PN 16 pressure rating as specified. 65mm dia

2

-

-

... More
50.18.9.3.2 : Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2

50

-

-

... More
50.18.9.4.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm dia 10.Kgf/cm2

50

-

-

... More
50.18.9.5.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge 40 mm dia 10Kgf/cm2

50

-

-

... More
50.18.9.6.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2

50

-

-

... More
18.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

6

-

-

... More
18.18.3 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore

2

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

1

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

1

-

-

... More
VALVES (E AND M)

-

-

-

... More
16.11.1.2 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) of 150 mm dia

5

-

-

... More
16.11.1.4 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 100 mm dia

14

-

-

... More
16.11.1.5 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 80 mm dia

9

-

-

... More
16.11.1.6 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 65 mm dia

11

-

-

... More
Sub head 3 - Electrical Works HT Cabling

-

-

-

... More
Supply of the following size 11kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. Supply - 3x300 Sqmm

225

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

180

-

-

... More
8.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm

15

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

30

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

5

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

3

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

10

-

-

... More
Transformer

-

-

-

... More
Supply, Installation, Testing and Commissioning of 1000kVA,11kV/433V, 3 phase, Copper Winding, Air Natural Cooling,DYN-11 Dry Type Indoor Transformer, Tappings from 5% to - 15% in steps of 1.25%, with vacuum type OLTC with RTCC and Incoming cable box suitable for 3Cx 300 sq.mm XLPE cable and LV side suitable for 1600A TPN(3+N) Al sandwich busduct IP 42 , as per IS 2026/IS 11171. Transformer losses shall be as per ECBC guidelines amended up to date. (Details technical specification attached)

2

-

-

... More
Distribution Boards

-

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

38

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

46

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

30

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - three phase double cover (IP 42/43)

11

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

17

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

16

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door

20

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

6

-

-

... More
Supplying and fixing following rating 40A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

10

-

-

... More
Supplying and fixing following rating 40A, FP, 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

42

-

-

... More
Supplying and fixing following rating 25A, FP, 415 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

6

-

-

... More
Supplying and fixing following rating 25A, DP, 240 V, RCBO, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

26

-

-

... More
Supplying and fixing following rating 63A, FP, 415 V, RCBO, having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

67

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

1732

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "D" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

900

-

-

... More
2.10.2 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural

30

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

5

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

70

-

-

... More
Supplying and fixing 25 amps to 32 amps TPMCB 415 V, 10 kA, "D" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

12

-

-

... More
Supplying and fixing 40 amps to 63 amps TPMCB 415 V, 10kA "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole

98

-

-

... More
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

35

-

-

... More
15.4.3 Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required3 output (1output per phase) and suitable for three phase supply

1

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

50

-

-

... More
Supply and fixing of 32A TPN Isolator in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation.

4

-

-

... More
Supply and fixing of 32A TPN Isolator ( W/P) in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation

4

-

-

... More
Supply and fixing of 32A DP Isolator in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation

2

-

-

... More
Supply and fixing of 40A DP Isolator (Car Charging) in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation

5

-

-

... More
Supply and fixing of 63A TPN Isolator in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation

5

-

-

... More
Supply and fixing of 63A TPN Isolator(W/P) in sheet steel powder coated enclosure with door interlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation

4

-

-

... More
2.18 : Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

10

-

-

... More
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

8

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

167

-

-

... More
LT Cabling and Termination

-

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx400sq.mm Al Cable

1316

-

-

... More
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date.3.5C 300 Sq mm Al

448

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx240sq.mm Al Cable

508

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx185sq.mm Al Cable

210

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx120sq.mm Al Cable

780

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5cx70sq.mm Al Cable

476

-

-

... More
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date.3.5C 35 Sq mm Al CABLE

1020

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3.5C x 50 sq.mm Al Cable

295

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx25sq.mm Al Cable

2644

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx16sq.mm Al Cable

2165

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx10sq.mm Al Cable

2365

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4cx 06 sq.mm Al Cable

357

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3CX185 sq.mm Al Cable

42

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3CX16 sq.mm Al Cable

48

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3cx04sq.mm CU Cable

50

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3cx2.5sq.mm CU Cable

75

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3C x 1.5sq.mm Cu Control Cable

52

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 6C x 1.5sq.mm Cu Control Cable

40

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4C x 1.5sq.mm Cu Control Cable

120

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4C x 2.5sq.mm Cu Control Cable

50

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 12C x 2.5sq.mm Cu Control Cable

320

-

-

... More
Supply laying and clamping of the following PVC sheathed unarmoured power cable conductor of best conductivity copper solid/stranded FRLS conductor, XLPE insulated, PVC inner sheathed 1.1kV grade strictly conforming to IS:694:1990 of the following sizes in existing cable tray /wall using factory made heavy gauge GI/painted MS clamps. Space between clamps not exceeding 60cms and making good the damages etc. as required and instructed by engineer in charge.e. 1C x 95 sq.mm Cuflexible Cable

1380

-

-

... More
7.3.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm

150

-

-

... More
7.3.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 35 sq. mm and upto 95 sq. mm

50

-

-

... More
7.3.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 95 sq. mm and upto 185 sq. mm

50

-

-

... More
7.3.4 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 185 sq. mm and upto 400 sq. mm

50

-

-

... More
7.4.4 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Above 185 sq. mm and upto 400 sq. mm

120

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

7780

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

1740

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

730

-

-

... More
7.8.4 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

2354

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

50

-

-

... More
14.3 : Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres.

50

-

-

... More
14.13.3 : Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re filling etc as required100 mm dia

18

-

-

... More
14.15.4 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.160 mm dia (OD-160 mm & ID-135 mm nominal)

350

-

-

... More
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

4

-

-

... More
9.1.16 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 185 sq. mm (57mm)

4

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

30

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

66

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

36

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

16

-

-

... More
9.1.30 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 300 sq. mm (70mm)

20

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

68

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ grade as required.4 X 10 sq. mm (25mm)

100

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

64

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

206

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

74

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

46

-

-

... More
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.70 sq mm

54

-

-

... More
Structural Earthing for ILPS + PME

-

-

-

... More
Providing and laying copper bonded steel solid round conductor 10mm diameter having 78 sqmm cross sectional area from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for earthing, lightning protection earthing system and ring equipotential bonding. Govt Approved Test Reports Required. Make: Cape Inside Structure for the formation of MAT & Vertical Riser Inside Structure this has to be installed with bonding clamp @ every 3 meters tested as per IS/IEC62305. Interconnecting round conductor and reinforcement inside the concrete for structural earthing system. Clamp materials has to be made of Mild Steel / Stainless Steel/ Copper Coated Steel ; Galvanised Steel Clmaps not Permitted based on Clause E.4.3.4 of IS 62305.

3250

-

-

... More
Providing and laying copper bonded steel solid round conductor 10mm diameter having 78 sqmm cross sectional area from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for earthing, lightning protection earthing system and ring equipotential bonding. Govt Approved Test Reports Required.Vertical Riser Outside Structure for PME

43

-

-

... More
Providing and laying copper bonded steel solid round conductor 10mm diameter having 78 sqmm cross sectional area from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for earthing, lightning protection earthing system and ring equipotential bonding. Govt Approved Test Reports Required. For Ring Earthing needs to be installed 0.5 meter from earth. Each under ground joints has to be wrapped with petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm.

495

-

-

... More
Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor having 100 microns or 25x3mm pure solid tape copper conductor as per IS/IEC 62305. Govt approved Indian labs test certificate required.

195

-

-

... More
Providing & fixing of Stainless Steel Straight Connectors for straight Joints if required. Govt approved Indian labs test certificate required.

330

-

-

... More
Providing and laying copper bonded steel solid tape conductor 17.2mm having 232Sq mm cross sectional area . copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 250microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. This has to be installed with bonding clamp @ every 1 meters tested as per IS/IEC62305. Interconnecting round conductor and reinforcement inside the concrete for structural earthing system. Clamp materials has to be made of Mild Steel / Stainless Steel/ Copper Coated Steel ; Galvanised Steel Clmaps not Permitted based on Clause E.4.3.4 of IS 62305. Needs to be installed in high fault level areas to form MAT inside structure. Govt approved Indian labs test certificate required

135

-

-

... More
Providing and laying copper bonded steel solid tape conductor 14.2mm having 158Sq mm cross sectional area . copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 250microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. This has to be installed with bonding clamp @ every 1 meters tested as per IS/IEC 62305. Clamp materials has to be made of Mild Steel / Stainless Steel/ Copper Coated Steel ; Galvanised Steel Clmaps not Permitted based on Clause E.4.3.4 of IS 62305. Needs to be installed in high fault level areas to form MAT inside structure. Govt approved Indian labs test certificate required

93

-

-

... More
Installation of Exothermic Weld Joints for 17.2mm/14.2mm round copper bonded steel conductor having 250 microns as per IS/IEC 62305 based on fault current. Govt approved Indian labs test certificate required.

45

-

-

... More
Providing & fixing of earth studs made of Stainless Steel tested as per IS/IEC 62305 having minimum dimension 40x40 for Lightning Protection application. Earth stud with connecting accessories inside the concrete - ( Earth stud + Bonding Clamp + Connecting Point + Green cover). Govt approved Indian labs test certificate required. Govt approved Indian labs test certificate required.

16

-

-

... More
Providing & fixing of earth studs made of Stainless Steel tested as per IS/IEC 62305 having minimum dimension 40x40 for Equipotential Bonding Rail application. This has to be connected to equipotential bonding rail to take multiple connection. Earth stud with connecting accessories inside the concrete - (Earth stud + Bonding Clamp + Connecting Point+ Equipotential Bonding Rail + Green cover). Govt approved Indian labs test certificate required. Govt approved Indian labs test certificate required

146

-

-

... More
Providing & fixing of earth studs made of Stainless Steel tested as per IS/IEC 62305 having minimum dimension 70x70 for General Earthing application. This has to be connected to equipotential bonding rail to take multiple connection. Earth stud with connecting accessories inside the concrete - ( Earth stud + Bonding Clamp + Connecting Point + Green cover). Govt approved Indian labs test certificate required.

18

-

-

... More
Providing & fixing of earth studs made of Stainless Steel with light duty equipotential bonding bar tested as per IS/IEC 62305 having minimum dimension 70x70 for General Earthing application. This has to be connected to equipotential bonding rail to take multiple connection. Earth stud with connecting accessories inside the concrete - ( Earth stud +Bonding Clamp + Connecting Point+ Equipotential Bonding Rail + Green cover). Govt approved Indian labs test certificate required

27

-

-

... More
Providing & fixing of earth studs made of Stainless Steel with heavy duty equi potential bonding bar tested as per IS/IEC 62305 having minimum dimension 70x100 for Body Earthing of Panel, Transformer, DG application. Minimum 3 connections to structural steel Required. This has to connected to heavy duty Stainless steel bonding rail to take multiple connection. Earth stud with connecting accessories inside the concrete - ( Earth stud + 3 nos of Bonding clamp + Equipotential Bonding Rail Heavy Duty+ Green cover). Govt approved Indian labs test certificate required.

21

-

-

... More
Providing & fixing of earth studs made of Stainless Steel tested as per IS/IEC 62305 having minimum dimension 80x150 for Neutral Earthing of Transformer, DG application. Minimum 5 connections to structural steel Required. Earth stud with connecting accessories inside the concrete ( Earth stud + 5 nos of Bonding clamp + Green cover). Govt approved Indian labs test certificate required

1

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. Make: Cape " 2 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories

1

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.br Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. Make: Cape " 3 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories

2

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5 Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. Make: Cape " 3 meter air terminal with Interception Tip mounted on Concrete Stone & Stainless Steel mounting accessories.

7

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. 4 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories

5

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports.Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test\ certificate required. Make: Cape " 4 meter air terminal with Interception Tip mounted on Concrete Stone & Stainless Steel mounting accessories

10

-

-

... More
"Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305)br Semi-hard (EAlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required. 6 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories

4

-

-

... More
Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters

540

-

-

... More
Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Make: Cape Conductor with Terrace Conductor Fibre Reinforce Concrete holder @ every 0.75 meters

98

-

-

... More
"Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Conductor with Parapet Holder made of whether resistant plastic holder @ every 0.5 meters

75

-

-

... More
Providing and fixing of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece with Connector: to route vertical down conductor /mesh formation made of Aluminium Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp/clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC 62305). Make sure all joints are strong and will be inspected at site. Galvanised Iron joints are not permitted to avoid risk of corrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required

70

-

-

... More
Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467. The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 m. It should be free from hazardous substances. The mineral compound is required to have minimum 17.5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. Concrete Earth electrode inspection chamber with weight bearing capacity of 30KN. The dimension shall be 320mmx 320mmx 190mm. Govt approved Indian labs test certificate required.

8

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

1240

-

-

... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip

56.72

-

-

... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 6 mm copper strip

170

-

-

... More
Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)50 x 6 mm copper strip

25

-

-

... More
Wiring and Accessories

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

1825

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

172

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire

39840

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

37540

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire

22745

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

500

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

500

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

100

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

1858

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

1756

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

1858

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

1756

-

-

... More
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

528

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

180

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

20

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

1324

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

530

-

-

... More
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

20

-

-

... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

1156

-

-

... More
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

1229

-

-

... More
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

302

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

1195

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

5264

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

3526

-

-

... More
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

550

-

-

... More
1.57 : Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

25

-

-

... More
Rising Mains, BBT Tap Off Boxes

-

-

-

... More
3.9.3 : Supplying, installing on wall or suspension on ceiling, testing and commissioning of following capacity Air Insulated Compact Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints, fire barrier at each floor, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.400 amps 30KA SC for 1 sec

52

-

-

... More
3.9.7 : Supplying, installing on wall or suspension on ceiling, testing and commissioning of following capacity Air Insulated Compact Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints, fire barrier at each floor, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required.1000 amps 50KA SC for 1 sec

95

-

-

... More
Supplying, installing on wall/ceiling, testing and commissioning of following capacity Air Insulated Compact Type Bus Trunking for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints expansion joints, fire barrier at each floor, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, Suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. 1600A AL TPN, 50kA feeder bus duct

57.92

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. 200 A 50kA TPN MCCB in Tap off box

10

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. 160A 50KA TPN MCCB in Tap off box

18

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP54, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished. 125 A 50kA TPN MCCB in Tap off box

14

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. The plug in / tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished.100 A 50kA TPN MCCB in Tap off box

6

-

-

... More
3.13.1 : Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 400 amps 25 KA SC for 1 sec

65

-

-

... More
3.13.5 : Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required1000 amps 50 KA SC for 1 sec

135

-

-

... More
Cable Tray

-

-

-

... More
4.1.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

125

-

-

... More
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

1025

-

-

... More
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

2260

-

-

... More
4.1.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

285

-

-

... More
4.2.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required100 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
4.2.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required150 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
4.2.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required300 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
4.2.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required600 mm width X 50 mm depth X 2.0 mm thickness

10

-

-

... More
4.3.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
4.3.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
4.3.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

85

-

-

... More
4.3.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

10

-

-

... More
4.4.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
4.4.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

45

-

-

... More
4.4.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

45

-

-

... More
4.4.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

5

-

-

... More
4.5.1 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
4.5.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

75

-

-

... More
4.5.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

75

-

-

... More
4.5.7 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0 mm thickness

10

-

-

... More
Miscellaneous Items

-

-

-

... More
Supply and providing 6mm thick MS chequered plates duly painted. Plates to be cut size as per site requirement.

80

-

-

... More
Supply and providing 2.5/3 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 11 kV dielectric strength conforming to IS 5429/1969

20

-

-

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters FIRE in black and gold or , duly painted over a coat of primer. Cost inclusive of providing 4 Nos of sand filled fire bucket and MS stand frame.

12

-

-

... More
Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.

8

-

-

... More
Supply and fixing single line diagram, schematic diagrams etc. of A0 size including laminations etc. as required complete on wall

1

-

-

... More
Supply and fixing single line diagram, schematic diagrams etc. of A1 size including laminations etc. as required complete on wall

2

-

-

... More
Supplying and Providing 15 long rubber hand gloves 15 kV

4

-

-

... More
Supply and providing First Aid Box.

2

-

-

... More
Providing and fixing M.V. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

12

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

-

-

-

... More
2x 150/160KVA (Parallel Redundant System) with Three Phase Input and Output :- The Three Phase input Voltage shall be 4wire, 415V, variable between +20% to –20%; 50Hz +/- 6%. The UPS System shall deliver Clean; ripple free output waveform in presence as well as failure of supply mains. The current and voltage harmonic distortions generated by the UPS systems shall be with in acceptable limits as per international and national norms. (Ripple [without Battery 1 %]), (THD 2% max, for 100% Linear load 5% max, for 100% Non-Linear load)" UPS system shall be Double conversion, Microprocessor based True On Line system with individual battery banks having in-built galvanic Isolation Transformer at output and own Cooling arrangements. UPS system shall be with LCD Display, 3 input and 3 output; with PWM IGBT based DSP control, 20 Minutes external SMF battery backup and auto by-pass.br "INPUT : Input Voltage Range -3, 4 Lines + Ground, 415V ± 20% Power factor - 0.98 Frequency Range - 50 Hz, ± 10% Topology - IGBT based DSP control OUTPUT: Voltage Range - 415V ± 0.5% Frequency Range - 50 Hz, ± 0.05% Crest Factor - 3:1 Efficiency - 95% Over load capacity - 110% - 5min , 150% - 30s" Battery Backup Required Battery backup time required is 20 Min. using External SMF Batteries for each UPS. The product of the offered battery Ah capacity and the total rated DC Bus voltage shall be a minimum of 120,000 (for SMF battery). "1. The entire UPS Systems shall be Tested, Supplied, and Erected and commissioned by supplier including all the components of the system such as Paralleling Kit, Batteries, Battery Rack, Interconnecting wires and Socket / Outlets. 2. The UPS System shall be rated continuously to deliver 100% of rated output at power factor of 0.9 lag to unity within KVA & KW rating. 3. Following original accessories / protective devices shall be provided for the UPS System. [a] Overload and Short Circuit Protection for Input and Load sides [b] Over voltage & under voltage Protection for UPS and Load [c] Low Battery [d] Over Temperature [e] LED Indications for Battery, Mains and Input Supply ON, Inverter ON, Static bypass. 4. The following connectors of adequate rating shall be provided for the UPS system [a] Power Outlet for connection to Load [b] Terminal connectors for connection to external Batteries [c] Connection to computer system for UPS Monitoring 5. The UPS and Battery System shall be suitable for installation in a Saline tropical area with relative humidity up to 95% and at altitudes of up to 1000 Mtrs above MSL without degradation. The ambient temperature is variable between +18deg.Centigrade to + 40deg. Centigrade. 6. The design of the UPS System and all components shall be tropicalised so as to ensure efficient and trouble free operation in the local climate. UPS Systems shall be despatched only after completing all Routine tests strictly complying to IEC 62040 – PART III . The complete set of test certificates shall be send to the Consultant before despatching the equipment. All tests shall be conducted to the entire satisfaction of the Engineer in Charge / Consultant. Any additional tests indicated by the Consultant if any / tests results he may think as unsatisfactory, shall be done without extra charges

1

-

-

... More
Generators , HT and LT Panel Boards, Enclosures and Accessories

-

-

-

... More
SMDB-UPS 7F(POWER) Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)100A FP ATS- 1No Outgoing:- a)50 A, 25 kA, TPN,TM, MCCB set at 40A - 8 Nos 100A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
SMDB-UPS 6F(POWER) Supply, Installation, Testing and Commissioning of factory fabricated OEM 415V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)160A FP ATS- 1No Outgoing:- a)63 A, 25 kA, TPN MCCB set at 50A - 4 Nos b)50 A, 25 kA, TPN MCCB set at 40A - 5 Nos 160A 415V 25kA best conductivity Al 4P bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
SMDB-UPS 5F(POWER) Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible.Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance.. Incomer:- a)125A FP ATS Outgoings:- a)63 A, 25 kA, TPN MCCB set at 50A -2 Nos b)50 A, 25 kA, TPN, MCCB 40A - 6 Nos 125A 4P 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
SMDB-UPS 4F(POWER) Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. ncomer:- a)160A FP ATS- 1No Outgoings:- a)63 A, 25 kA, TPN, MCCB set at 50A -3 Nos b)50 A, 25 kA, TPN, MCCB set at 40A- 5 Nos 160A 4P 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD shown in SLD

1

-

-

... More
SMDB-UPS 3F(POWER) Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. ncomer:- a)160A FP ATS-1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB -3 Nos b)50 A, 25 kA, TPN,TM, MCCB - 5 Nos 160A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
SMDB-UPS SF(POWER) Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)160A FP ATS-1No.Outgoings:- a) 63 A, 25 kA, TPN, MCCB set at 50A -3 Nos b)50 A, 25 kA, TPN, MCCB set at 40A - 5 Nos 160A 4P 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
SMDB-UPS FF(POWER) Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock -outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)100A FP ATS- 1No Outgoings:- a)50 A, 25 kA, TPN, MCCB set at 40A-6Nos, 100A 4P 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement.Details to be as shown in SLD.

1

-

-

... More
SMDB-UPS GF(POWER) Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)100A FP ATS Outgoings:- a) 50 A, 25 kA, TPN,TM, MCCB - 5 Nos b)40 A, 25 kA, TPN,TM, MCCB - 1 Nos 100A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
APFC PANEL -275 kVAr Supply, Installation, Testing and Commissioning of factory fabricated OEM 415V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Adequate forced ventilation arrangement shall be provided by means of a cubicle type fan of capacity 225 m3/hr also with contactor thermostat control. Control fuses shall be provided for the fan circuit. Lamp indication shall be provided to indicate the working/ non- working states of the fan. The capacitor compartment shall be so constructed that in case of any capacitor failure, fluid leakage or fumes from the field capacitor shall not affect the capacitors in the other compartments. The inter-compartmental partition of capacitor chamber shall be perfectly done. The capacitor shall be rated for a voltage 480 V or above and conform to IS - 2834. Incomer a) 800A TPN Isolator-1No Outgoings a)160A TPN 36KA MCCB-3 Nos. b)80A TPN 36KA MCCB-3 Nos. c)63A TPN 36KA MCCB-2 Nos d)40A TPN 36KA MCCB-1 Nos Capacitor: 50kVAR Capacitor Duty Contactor - 3 Nos 25kVAR Capacitor Duty Contactor - 3 No 20kVAR Capacitor Duty Contactor - 2 No 10kVAR Capacitor Duty Contactor - 1 No 50kVAR Heavy Duty Capacitor Box Type Resin Filled -3 Nos 25kVAR Heavy Duty Capacitor Box Type Resin Filled -3 Nos 20kVAR Heavy Duty Capacitor Box Type Resin Filled -2No 10kVAR Heavy Duty Capacitor Box Type Resin Filled -1 No 7% detuned reactor – 9 nos.12 Stage APFC Relay - 1 No 800A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD. Complete with all Control Wiring Components such as Control Contactors, Selector Switch, Push Button with Elements, Control MCB's etc. as required

2

-

-

... More
SMDB-SP 7F-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)80A TPN ISOLATOR Outgoings:- a) 50 A, 25 kA, TPN,TM, MCCB - 5 Nos a) 63 A, 25 kA, TPN,TM, MCCB-1 Nos 80A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 7F FLOOR PANEL-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance.Incomer:-a)1 No 200A 4P ATS Outgoings:- a) 80 A, 36 kA, TPN,TM, MCCB - 3 Nos b) 125 A, 36 kA, TPN,TM, MCCB - 2 Nos c) 63 A, 36 kA, TPN,TM, MCCB - 1 No 200A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
SMDB-SP 6F-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet,Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:-a)80A TPN ISOLATOR Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 6 Nos 80A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 6F FLOOR PANEL-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates.The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)1 No 125A 4P ATS-1No br Outgoings:- a) 80 A, 36 kA,TPN,TM, MCCB - 3 Nos b) 63 A, 36kA, TPN,TM, MCCB - 2 Nos 125 A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
SMDB-SP 5F-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:-a)125A TPN ISOLATOR-1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 7 Nos 125 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 5F FLOOR PANEL-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)1 No 160A 4P ATS Outgoings:- a) 125 A, 36 kA, TPN,TM, MCCB - 1 Nos b) b)100 A, 36 kA, TPN,TM, MCCB - 1 Nos c) 80 A, 36 kA, TPN,TM, MCCB - 1 Nos d) 63 A, 36 kA, TPN,TM, MCCB - 2 Nos 160 A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP 4F-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber,Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)125A TPN ISOLATOR- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 7 Nos 125 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 4F FLOOR PANEL-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates.The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 160A 4P ATS- 1No Outgoings:- a) 125 A, 36 kA, TPN,TM, MCCB - 2 Nos b)80 A, 36 kA, TPN,TM, MCCB - 2 Nos c)63 A, 36 kA, TPN,TM, MCCB - 1 Nos 160 A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP 3F-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA,DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)125A TPN ISOLATOR b)2 Set RYB Indication Lamp c)1 No (0-200)A Ammeter with Selector Switch f)1 No (0-500)V Voltmeter with Selector Switch g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 8 Nos 125 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 3F FLOOR PANEL-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 200A 4P ATS-1 Nos Outgoings:- a) 160 A, 36 kA, TPN,TM, MCCB - 2 Nos c) 63 A, 36 kA, TPN,TM, MCCB - 3 Nos 160 A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP 2F-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)125A TPN ISOLATOR Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 7 Nos 125 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 2F FLOOR PANEL-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)1 No 200A 4P ATS Outgoings:- a) 80 A, 36 kA, TPN,TM, MCCB - 2 Nos b) 100 A, 36 kA, TPN,TM, MCCB - 2 Nos c) 125 A, 36 kA, TPN,TM, MCCB - 1 Nos 200 A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP 1F-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)125A TPN ISOLATOR- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 6 Nos 125 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 1F FLOOR PANEL-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)200A 4P ATS- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 2 Nos b) 80 A, 25 kA, TPN,TM, MCCB - 1 Nos c)100 A, 36 kA, TPN,TM, MCCB - 1 Nos d)125 A, 36 kA, TPN,TM, MCCB - 1 Nos 200 A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP GF-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. ncomer:- a)80A TPN ISOLATOR- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 6 Nos 80 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
SB GF FLOOR PANEL-02 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)125A 4P ATS- 1No Outgoings:- a) 125 A, 25 kA, TPN,TM, MCCB - 2 Nos b) 80 A, 25 kA, TPN,TM, MCCB - 2 Nos c) 100 A, 25 kA, TPN,TM, MCCB - 1 Nos 125 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP 7F-01 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)80A TPN ISOLATOR-1 No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 2 Nos b) 50 A, 25 kA, TPN,TM, MCCB - 3 Nos 80 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 7F FLOOR PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. a) 160A 4P ATS-1No Outgoings:- a) 80 A, 25 kA, TPN,TM, MCCB - 4 Nos b) 63 A, 25 kA, TPN,TM, MCCB - 1 Nos c)100 A, 25 kA,TPN,TM, MCCB - 2 Nos 160 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with controlfuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP 6F-01 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. ncomer:- a)80A TPN ISOLATOR-1 No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 5 Nos 80A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 6F FLOOR PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)160A 4P ATS- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 2 Nos b) 80 A, 25 kA, TPN,TM, MCCB - 4 Nos 160 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C/ Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP 5F-01 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)80A TPN ISOLATOR-1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 6 Nos 80 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 5F FLOOR PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)160A 4P ATS- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 1 Nos b) 80 A, 25 kA, TPN,TM, MCCB - 4Nos 160 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
SMDB-SP 4F-01 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)80A TPN ISOLATOR- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 6 Nos 80 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 4F FLOOR PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates.The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 160A 4P ATS- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 3Nos b) 80 A, 25 kA, TPN,TM, MCCB - 2 Nos' br160 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP 3F-01 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)100A TPN ISOLATOR- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 7 Nos 100 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 3F FLOOR PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switchgears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 160A 4P ATS-1No Outgoings:- a) 80 A, 25 kA, TPN,TM, MCCB - 2 Nos b) 100 A, 25 kA, TPN,TM, MCCB - 3 Nos c) 125 A, 25 kA, TPN,TM, MCCB - 1 Nos 160 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
SMDB-SP 2F-01 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)80ATPN ISOLATOR Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 6 Nos 80A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 2F FLOOR PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates.The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)1No160A 4P ATS Outgoings:- a) 80 A, 25 kA, TPN,MCCB - 2 Nos b) 100 A, 25 kA, TPN, MCCB - 3 Nos 160 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB-SP 1F-01 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)80A TPN ISOLATOR Outgoings:- a) 63 A, 25 kA, TPN, MCCB - 5 Nos 80A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator withreal time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB 1F FLOOR PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 160A 4P ATS- 1No Outgoings:- a) 80 A, 25 kA, TPN, MCCB - 2 Nos b) 100 A, 25 kA, TPN, MCCB - 3 Nos 160 A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SMDB SP GF Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 80A TPN ISOLATOR- 1No Outgoings:- a) 63 A, 25 kA, TPN,TM, MCCB - 6 Nos 80A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB GF -01 Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. a) 125A 4P ATS-1No Outgoings:- a) 100 A, 25 kA, TPN,TM, MCCB - 2 Nos b) 80 A, 25 kA, TPN,TM, MCCB - 2 Nos c) 50 A, 25 kA, TPN,TM, MCCB - 1 Nos 125A 415V 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
UPS O/P PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 400A TPN 36KA MCCB-2Nos. Outgoings:- a) 400 A, 36kA, TPN, MCCB - 2 Nos b) 125A, 36 kA, TPN, MCCB- 2 Nos c) 63A, 36 kA, TP, MCCB - 1Nos 400 A 415V 4P best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with necessary CT RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
MEDICAL EQUIPMENT PANEL -1:- Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer: - 630 A, TPN, Isolator - 1 No Outgoings:- 320A, 50kA, TP+NL, Thermal Magnetic Release Based MCCB set at 230A - 2 Nos . 125A, 50kA, TP+NL Thermal Magnetic Release Based MCCB set at 100A - 3 Nos. 63A, 25kA, TP+NL Thermal Magnetic Release Based MCCB set at 50A - 2 Nos. 630A 415V, 50kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Necessary interlocking arrangement Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
MEDICAL EQUIPMENT PANEL -2:- Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance.br Incomer - 800A, TPN, Isolator - 1 No. Outgoings 400A, 50kA, TP+NL Thermal Magnetic Release Based MCCB set at 320A - 1 Nos 320A, 50kA, TP+NL, Thermal Magnetic Release Based MCCB set at 250A - 1 Nos . 250A, 50kA, TP+NL Thermal Magnetic Release Based MCCB set at 200A- 2 Nos. 125A, 25kA, TP+NL Thermal Magnetic Release Based MCCB set at 100A - 2 Nos. 800A 433V, 50kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement.brMulti function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB UTILITY PANEL 01"Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2.The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. "Incomer :- 400 A TPN Isolator - 1 No. Outgoings:- 200A 50kA TP+NL Thermal Magnetic Based MCCB set at 160A - 2 Nos. 125A 50kA TP+NL Thermal Magnetic Based MCCB set at 100A- 4 Nos. 400A 433V, 50kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement.Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 +2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicatingLED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB UTILITY PANEL 02 "Supply, Installation, Testing and Commissioning of factory fabricated OEM 415V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. "Incomer - 630 A TPN Isolator - 1 No. Outgoings:- 250A 50kA TP+NL Thermal Magnetic Based MCCB set at 200A - 3 Nos. 160A 25kA TP+NL Thermal Magnetic Based MCCB set at 125A - 2 Nos. 125A 50kA TP+NL Thermal Magnetic Based MCCB set at 100A- 2Nos. 63A 50kA TP+NL Thermal Magnetic Based MCCB set at 50A - 1 No. 40A 50kA TP+NL Thermal Magnetic Based MCCB set at 32A - 4 Nos. Details to be as shown in SLD. Panel shall be BMS compatible. 630A 415V, 50kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement.brMulti function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with controlfuses and switches - 1 set.

1

-

-

... More
SB LIFT PANEL "Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. "Incomer - 630A, TPN Isolator - 1No. Outgoing 250A, TPN, 50KA MCCB set at 200A - 4 Nos. 80A, TPN 36 KA MCCB set at 63A-2 Nos. 630A, 415V, 50 kA best conductivity Al FP bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
SSB LIFT PANEL 1 to 3 " Supply, Installation, Testing and Commissioning of factory fabricated OEM 415V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. "Incomer - 250A, TPN MCCB Isolator - 1No. 250A, 415V, 25 kA best conductivity Al TPN bus barwith SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoing 80A, TPN, 36KA MCCB set at 63A - 6 Nos. Details to be as shown in SLD

3

-

-

... More
LIFT PANEL 1 to 13(Typical) Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 80 A, TPN Isolator - 1No. Outgoings:- a) 63A, 100 mA, FP, RCBO - 1 Nos. b)25A DP 30mA, RCBO - 1 Nos. 80A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

13

-

-

... More
Emergency Lighting :-Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA,ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)160A TPN ISOLATOR-1No Outgoings:- A) 63 A, 25 kA, TPN,TM, MCCB - 7 Nos 160 A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
SB-LGF Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 400A TPN ISOLATOR- 1No Outgoings:- a) 160 A, 36kA, TPN, MCCB set at 125A -4 Nos b) 125A, 36KA, TPN TM, MCCB set at 100A-1 Nos c) 63A, 36kA, TPN,TM, MCCB set at 50A - 4 Nos 400 A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD.

1

-

-

... More
SB EV CHARGING Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)125 A, TPN Isolator - 1No. Outgoings:- a) 80A 25kA TP+ NL Thermal Magnetic Based MCCB set at 63A- 2 Nos. b) 32A 25kA TP+ NL Thermal Magnetic Based MCCB set at 25A- 6 Nos. 125A 415V, 25kA, best conductivity extensible TPN Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C/ Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
SB PHE PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer a)160 A TPN Isolator - 1No. Outgoings:- a)125A, 36kA, TPN Thermal Magnetic Based MCCB set at 100A - 1 Nos. b) 80A, 36kA, TPN Thermal Magnetic Based MCCB set at 63A- 2 Nos. c) 63A, 36kA, TPN ThermalMagnetic Based MCCB set at 50A - 2 No. d) 40A, 36kA, TPN Thermal Magnetic Based MCCB set at 32A- 1 Nos. 9 Sets of ON-OFF-TRIP Lamps with 2A fuse 160A, 415V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
SB EXT LIGHTING PANEL Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a) 100 A, TPN Isolator - 1No. Outgoings:- a) 63A 16kA TP+ NL Thermal Magnetic Based MCCB - 6 Nos. 100A, 415V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required.Necessary interlocking arrangement. Multi function digital LCD meters with maximum demand indicator with real time clog with accuracy class 1, with necessary CT Class B+C / Class 1 + 2 Surge arrestor device with necessary MCB for back-up protection - 1 No. RYB phase indicating LED lamps with control fuses and switches - 1 set. Details to be as shown in SLD

1

-

-

... More
MEDICAL GAS PLANT PANEL Supply, Installation, Testing and Commissioning of 415 V 50Hz LT Switch board OEM Design Verified Assembly Panel complying to IEC 61439 Part 1 & 2.The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with 14 SWG CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer:- a)200A TP +NL Isolator - 1 No. b)1 Set RYB Indication Lamp c) 2A SP MCB 10kA d) 200/5A CL:1, 10VA CT e)1 No (0-200)A Ammeter with Selector Switch f)1 No (0-500)V Voltmeter with Selector Switch g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PFbr Outgoings:- a) 100A 25kA TP+ NL MCCB, with thermal magnetic release - 2 Nos. b) 80A 25kA TP+ NL MCCB, with thermal magnetic release - 2 Nos. c) 63A 25kA TP+ NL MCCB, with thermal magnetic release - 1 No d)5 Sets of ON-OFF-TRIP Lamps with 2A fuse 5 Sets of Multifunction Digital meter V,A,F,KW,KVA,PF with suitable CT 200A 415V best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Details to be as shown in SLD.

1

-

-

... More
HVAC Pump Panel : Supply, Installation, Testing and Commissioning of 415 V 50Hz LT Switch board OEM design verified assembly panel complying to IEC 61439 Part 1 & 2.The Enclosure shall be selfsupported, free standing powder coated compartmentalized cubicle type with 14 SWG CRCA sheet, Ingress Protection rating shall be IP42 & Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. a)Incomer - 400 A TP+ NL Isolator - 1 No. b)1 Set RYB Indication Lamp c)1 No (0- 400)A Ammeter with Selector Switch d)1 No (0-500)V Voltmeter with Selector Switch e)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a)200A, 25kA, TP+ NL Thermal Magnetic Based MCCB - 1 No. b)100A, 25kA, TP+ NL Thermal Magnetic Based MPCB - 2 Nos. c) 63A, 25kA, TP+ NL Thermal Magnetic Based MCCB - 5 Nos. d) 32A, 25kA, TP+ NL Thermal Magnetic Based MCCB - 9 Nos. ON-OFF-TRIP Lamps with 2A fuse as per SLD 400A, 433V best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
HVAC CHILLER PANEL :-Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board design verified assembly panel complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or above. with Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grade for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB appropriately rated HRC fuses. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level. All panels must be BMS compatible. . Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Incomer - 1000 A, 50KA TPN ACB EDO Micro processor based with O/C E/F Releases and S/T ,O/V relay with Primary Trip, 1set ONOFF Indication Lamp, 2A SPMCB with control fuse, (0-800 A) Ammeter with ASS, (0-500) V Voltmeter with VSS, MFDM, suitable CT for Metering etc. Outgoings:- 320A, 36kA, TP+NL, Thermal Magnetic Release Based MCCB - 6 Nos . ON-OFF-TRIP Lamps with 2A control fuses - 6 Set. 1000A 415V, 50kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc\ complete as required. Details to be as shown in SLD.

1

-

-

... More
DG Synchronisation Panel - Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance.OEM certification is also mandatory.The panel shall be with PLC components for Synchronisation of 3Nos. of 750KVA, 625KVA & 400KVA DG Sets, Auto Load Sharing, AMF which includes synchronising relays, UPS for PLC and all connections and interconnections required for synchronising and load sharing for 3 nos. of DG sets and individual Generator selection and control facilities as well as mimic diagram. INCOMER-1 - 750KVA DG-1 ,1250A 50kA TP Microprocessor based EDO Type ACB with 3 O/C, 1E/F, U/F & S/T releases set at 1050A. INCOMER-2 - 625KVA DG-2, 1000A 50kA TP Microprocessor based EDO Type ACB with 3 O/C, 1E/F, U/F & S/T releases set at 875A. INCOMER-3 - 400KVA DG-3, 800A 50kA TP Microprocessor based MCCB with 3 O/C, 1E/F, U/F & S/T releases set at 560A. 1 EF & Shunt Releases - 1 No. 300A 3P power contactor - 1Nos. Lowset E/F Relay 51 G - 1 Sets. (Considered for All 3 DG's) CRCT 300/5A 15 VA CL:5P10 - 1 Nos (Considered for All 3 DG's) Reverse power Relay 32 - 1 Set CRCT 1000/5A 15 VA CL:1 - 3 Nos ON OFF TRIP Indication & ON OFF Push Button RYB Indication lamp and control fuses/MCB - 1 Set Multi function digital LED meters with RS 485 port class 1, with necessary CT and accessories -1Set. outgoings aretwo numbers of 1600A 50KA TPN based EDO TYPE ACB. The details of meters, relays and associated items shall be as per the approved scheme. Wiring from all meters shall be terminated in a gateway(s) (PAS 6000 or equivalent) to make the system EMS compatible. The panel shall be certified by the respective OEM and the original certificate shall be submitted. Original copy of design verification certificate of the respective OEM shall be submitted with the panel.

1

-

-

... More
MAIN PANEL - Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory Incomers EB Incomer 1 2- 1600A, 50kA, FP, EDO,1333A over load setting, Microprocessor based ACB with 3 O/C and 1 E/F releases. Standby low set E/F relay with CT at neutral earthing conductor, O/V relay with primary trip - 2 Sets. DG Feeder 1 2 - 1600A, 50kA, FP, EDO, Microprocessor based ACB with 3 O/C and 1 E/F releases , overload and E/F release Standby low set E/F relay with CT at neutral earthing conductor + Necessary rating neutral contactor - 2 Sets. 1600A 415V, 50kA best conductivity Al FP bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement Digital LED power quality meters with necessary 0.50 accuracy class CT and accessories for measuring Voltage, Current, Frequency, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interrupts, Phase angle, THD, Neutral current, Max Demand (with RTC),Events (high-low) with time stamp,Individual Harmonics upto 31st, Meter with Ethernet port - 4 Sets RYB phase indicating LED lamps with control fuses and switches - 4 set. Class B Class C/ Class 1 Class 2 Surge arrestor device with necessary HRC Fuse for back-up protection - 2 Sets. 1600A, FP, 50 kA, EDO, Microprocessor based ACB as Buscoupler - 1 No, Outgoings 1250A TPN 50KA microprocessor based ACB -1No 1000A TPN 50KA microprocessor based ACB -7Nos, 800A 50kA TP+NL Microprocessor Based MCCB - 5 Nos, 630A 50kA TP+NL Microprocessor Based MCCB - 6 Nos , 400A 50kA TP+NL Microprocessor Based MCCB - 6 Nos 630 A TP+NL Isolator - 1 No. Wiring from all meters shall be terminated in a gateway(s) (PAS 6000 or equivalent) to make the system EMS compatible. Original copy of design verification certificate of the respective OEM shall be submitted with the panel

1

-

-

... More
HT PANEL Supply, installation, testing and commissioning of dust and vermin proof floor mounted free standing cubicle type, 11kV, extensible panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors interlocked with the earth switch,comprising of one number of 800A VCB as incomer and two numbers of 800A VCB as outgoings as per the specification details below including providing station class polymeric type surge arrestor (10kA) for incomer with necessary switch for protection of same. Outgoings with breaking capacity 26.3 kA for 3 sec to be provided with over current + Earth fault relays with high set element, auto relays for door-interlock,provided with winding temperature alarm/trip etc. Each VCB panel also include POWER PACK/UPS of required capacity for auxilary power supply unit with all accessories required for complete installation as required and providing all connection and interconnections as required and as instructed by engineerin charge/consultant Incomer 1no:-11kV 800A, 3phase 50Hz, 500MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection metering. Draw out type resin cast P.T with inbuilt fuses of ratio 11kV/110V, CL : 0.5, must be provided. Bus bar compartment shall have suitable capacity non-hygroscopic and high dieletric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. Metering compartment for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, under voltage release (Not required), RYB indication lamps, cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar CB truck enclosures and powder coating complete panel as per IS-2516 IS 3427 with latest amendments complete as required with manually charged spring closing system. It shall also be provided with Instantenous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. CT Rating : 100/1/1: Core 1: CL-0.5, Core 2: 5P10 Out goings : 2 Nos:-11kV 800A, 3phase 50Hz, 500MVA, breaking capacity vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection. Drawout type resin cast P.T. with inbuilt fuses of ratio 11kV/110V must be provided (can be removed as only one voltage reference is required). Bus bar compartment shall have suitable capacity non-hygroscopic and high dieletric strength SMC/FRP busbar supports with electrolytic aluminium busbars covered with suitable sleeves. Metering compartment for each outgoing mounting digital meter and numerical relays for transformer protection,shunt/series trip coil, under voltage release (Not required), indication lamps, cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar CB truck enclosures and powder coated with approved colour complete panel as per IS-2516 IS 3427 with latest amendments complete as required as instructed by engineer in charge/consultant. It shall also be provided with Instantenous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. CT Rating :50/1/1: Core 1: CL-0.5, Core 2: 5P10. (Company fabricated OEM panels alone shall be supplied)

1

-

-

... More
HT Metering Cubicle OUTDOOR WITH TOD METER: Supply, erection, testing and commissioningof dust and vermin proof, floor mounted free standing cubicle type 11kV outdoor metering panel box IP67, fully compartmentalised complete with hinged and earthed front doors with 3 phase 4 way 110V (LL), 5A, class: 0.2 S, TOD meter with RS485 port, of Electricity board approved make including all necessary accessories for fixing and connection complete as required getting tested and approved from statutory authorities, providing connection/inter-connections as required for complete installation and as instructed by engineer in charge/consultant. Also the panels unit shall comprise of 3 Nos CT's of 10VA burden, and class Cl: 0.2 S and ratio depending on contract demand including fixed type PT of ratio 11kV/110V, 25VA, Cl: 0.2S (1 No.) and seal off bushing & ABC Termination, space heater with thermostat including 800A Aluminium busbars with support insulators and all other accessories as required for complete installation as required and instructed by engineer in charge as per KSEB standards

1

-

-

... More
Design, Fabrication, Supply, Installation Testing and Commissioning of factory fabricated OEM11KV electrically Operated 21kA for 3 sec, 630A SF6 Insulated Ring Main Unit outdoor type with 2 nos motorized Load Break Switch as incomer and 1 no. motorized Non drawout type VCB (fully rated earth switch) , 630 Amp continously rated Cu busbar complete with all accessories, protective relays, indicators, Hooter ,battery and battery charger, Manometer for indicating SF6 gas pressure with green zone marked on the scale,provision for padlocking for open, close, earth and test position etc. on a suitable foundation. The RMU must be both side extensible type and compatible for SCADA system.The rate quoted shall be inclusive of hoisting to its location,assembling of units,lining up, bolting the units and checking all control wiring complete as per single line diagram.

1

-

-

... More
Supply, Installation, Testing and Commissioning of 400 kVA prime rated D.G set with acoustic enclosure and control panel, protection and digital metering, controls and interlocks, CT's and transducers for all metering and protection with suitable size breaker, suitable for AMF operation and synchronization,including antivibration mountings, exhaust silencer and exhaust piping including MS support conforming to latest environment protection regulations for emission and noise levels, water/coolant cooled, ( radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz,3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications. Rate shall be inclusive of exhaust pipe as per the detailed technical specification. The work should be as per Electrical Inspectorate / pollution control board standards.(Civil works excluded).

1

-

-

... More
Supply, Installation, Testing and Commissioning of 625 kVA prime rated D.G set with acoustic enclosure and control panel, protection and digital metering, controls and interlocks, CT's and transducers for all metering and protection with suitable size breaker, suitable for AMF operation and synchronization,including antivibration mountings, exhaust silencer and exhaust piping including MS support conforming to latest environment protection regulations for emission and noise levels, water/coolant cooled, ( radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz,3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications. Rate shall be inclusive of exhaust pipe as per the detailed technical specification. The work should be as per Electrical Inspectorate / pollution control board standards.(Civil works excluded).

1

-

-

... More
Supply, Installation, Testing and Commissioning of 750 kVA prime rated D.G set with acoustic enclosure and control panel, protection and digital metering, controls and interlocks, CT's and transducers for all metering and protection with suitable size breaker, suitable for AMF operation and synchronization,including antivibration mountings, exhaust silencer and exhaust piping including MS support conforming to latest environment protection regulations for emission and noise levels, water/coolant cooled, ( radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz,3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications. Rate shall be inclusive of exhaust pipe as per the detailed technical specification. The work should be as per Electrical Inspectorate / pollution control board standards.(Civil works excluded).

1

-

-

... More
Supply, installation, testing and commissioning of Energy Management System (EMS) as per the attached architecture and as explained in the Detailed Technical Specifications (DTS) consisting of Modbus gateway with Dual Ethernet port to convert RS 485 to Modbus TCP (For RS485 meters), required power supply for gateway and smart link, ISO 50001/50006 certified Power Monitoring software, Web View Software, server/ workstation PC as explained in the DTS, connected Service Plan for performing System analysis and network Analysis -Advisor service connected Prime plan[twice a year] connecting upto 90 credit points, Smark link / Easycom etc as required. The system should support a minimum of the following meters and devices or their equivalent approved makes: ION9000, PM8240, PM5560, PM2230H, PM1130H, EM6400NG, EM6438H, EM7230, MTZ with EIFE, NW with IFE, NSX with IFM/IFE, Smartlink Modbus, PowerTag, HeatTag, Wireless Thermal Sensors, Energy relays, Panel Server etc.

1

-

-

... More
Light Fittings

-

-

-

... More
Supply of LED recessed downlight fixture Maximum 18W light fixture . System efficacy 100 lm/W and system lumen output not less than 1800 lm. Luminaire shall have satin finished prismatic diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor /=0.95, THD/=10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19, SDCM5 and CCT in between 5000K to 6500K, Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture.EMI/EMC compliance ,LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make

273

-

-

... More
Supply of LED recessed downlight fixture Maximum 12W light fixture , System efficacy 100 lm/W and system lumen output not less than 1200 lm. Luminaire shall have satin finished Prismatic diffuser for Uniform illumination and wider light distribution with Die Cast Aluminium powder coated housing, driver with minimum 2.5 KV internal surge protection with electronic drive system, power factor /=0.95,THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19, SDCM5 and CCT in between 5000K to 6500K, Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture.EMI/EMC compliance, LM79, LM80, type test certificate & BIS certificate shall be submitted,Luminaire/drive shall be BIS approved of same make

544

-

-

... More
Supply of LED Tube Lights of 40W(+/- 10% Tolerance) with minimum system lumens 4800 Lumens with system efficacy 120lm/W. Extruded Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 2.5KV Surge protection inbuilt with electronic drive system, , SDCM5 and CCT in between 4000K to 5700K, power factor 0.95, THD10%,rated life of 50,000 hours at L70, with a CRI 80, or above, Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture.. EMI/EMC compliance LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/drive shall be BIS approved of same make

355

-

-

... More
Supply of single dome LED Aviation Light

3

-

-

... More
Supply of 2x 2 LED Recess mounted 25W light fixture ,System efficacy 110 lm/W and system lumen output not less than 2750 lm. Luminaire shall have satin finished prismatic diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19, SDCM5 and CCT in between 5000K to 6500K, Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. EMI/EMC compliance, LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/drive shall be BIS approved of same make

1353

-

-

... More
Supply of 2x 2 LED Recess mounted 30W light fixture ,System efficacy 110 lm/W and system lumen output not less than 2750 lm. Luminaire shall have satin finished prismatic diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19, SDCM5 and CCT in between 5000K to 6500K, Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. EMI/EMC compliance, LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/drive shall be BIS approved of same make

150

-

-

... More
Supply of 2x 2 LED Recess mounted 30W light fixture ,System efficacy 110 lm/W and system lumen output not less than 3100 lm. Luminaire shall have satin finished prismatic diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19, SDCM5 and CCT in between 5000K to 6500K, Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. EMI/EMC compliance, LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/drive shall be BIS approved of same make

803

-

-

... More
Supply of 2x2 LED Recess mounted light fixture 42W Clean Room light fixture.Power consumption not more than 42W. Bottom Opening frame. System efficacy =100 lm/W and system lumen output not less than 4200 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor 0.9, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 22, SDCM5 and CCT in between 4000K to 5700K, Luminaire shall be flicker free with ripple content is less than 5%, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. EMI/EMC compliance,LM79, LM80, type test certificate & BIS certificate shall be submitted,Luminaire/Drive shall be BIS approved of same

122

-

-

... More
Supply of 10W LED BULKHEAD LIGHT fixture , System efficacy =110 lm/W and system lumen output not less than 1100 lm. , driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, SDCM5 and CCT in between 5000K to 6000K, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/drive shall be BIS approved of same make

124

-

-

... More
Supply of LED Mirror Lights of Maximum 12W light fixture. System efficacy =100lm/W and system lumen output not less than 1200 lm. driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor /=0.95, THD=10%, rated life of 50,000 hours at L70 with a CRI 80, SDCM5 and CCT in between 5000K to 6000K, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. LM79, LM80, type test certificate & BIS certificate shall be submitted

74

-

-

... More
Supply of 2x 2 LED Recess mounted 36W light fixture . System efficacy 110 lm/W and system lumen output not less than 4320 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor 0.9, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 22, SDCM5 and CCT in between 4000K to 5700K, Luminaire shall be flicker free with ripple content is less than 5%, ANSI rated LEDs from reputed makes should be provided and including all necessary accessories as required for the light fixture. EMI/EMC compliance, LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/drive shall be BIS approved of same make

1197

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

528

-

-

... More
SITC of Industrial Type 400mm Sweep Exhaust fan

15

-

-

... More
EXTERNAL FEEDER PILLAR Supply and installation of Thermoplastic polycarbonate Junction Box IP67. Junction box should be made of thermoplastic Polycarbonate, having IP 67 degree of protection and 5pole terminals suitable to terminate up to 2.5sqmm. The color of Junction boxes shall be Siemens Grey RAL7035. The gasket should be internally embedded, and made of Polyurethane The boxes shall be tested as per IEC 60670-2 / 60670-22. The boxes shall have self- threaded holes & provision for mounting din rail, The boxes should withstand temperature of -40c to +120c, The glow wire test should be conducted at 960c, and material should be flame retardant & self- extinguishing. UL subject 94, V-0. The boxes should be free of toxic substances like halogen and silicon, The boxes should have suitable premolded knock out, suitable size IP68 polyamide glands shall be provided for in and out cables / wires. Incomer: 63A,TPN Isolator,63A ,30mA RCCB,Outgoing: 15 nos. 6/10/16/20A SP MCBs , 10KA.

1

-

-

... More
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

4995

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

5920

-

-

... More
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required

344

-

-

... More
90.15.3.1 : Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters

10

-

-

... More
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

10

-

-

... More
Sub head 4 - Heating, Ventilation and Air Conditioning System Water Chilling Plant

-

-

-

... More
Supply at site including local transport with full cover insurance, fire or any other contingencies, unload, store, handle, erect, balance, test and commission the entire water chilling plant as per specifications including all accessories as specified for water chilling plant. WATER COOLED VFD SCREW CHILLER - (R-134A/410) OF MINIMUM CAPACITY 170 TR. Minimum Overall Chiller efficiency offered shall have COP 5.8 AS PER ECBC + Buildings 2017/ ASHRAE / ARI 550/590 & IPLV 7.5., Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F, Comprising of Screw Compressor as per specifications. Drive motors of suitable ratings 415+/- 10% Volts 50 Hz AC supply and starter panel with VFD starter. Water cooled condenser with all accessories. Automatic capacity control unit to regulate the capacity down to 25%. Micro-processor control panel. Building management system compatible software Data Link / Micro Gateway for integration with third party BMS on Modbus / BACNET protocol, Safety controls as per spec. wiring and interlock between pumps shall be included in the chiller cost. The cost for additional incoming metering panel for each chiller to be included in the chiller. Water cooled chiller with all accessories: LOT-integral mounting frame for all the components, LOT-refrigerant piping & valves, LOT-insulation of chiller and suction line(in compliance with ECBC + building guidlines), LOT-first charge of refrigerant and lube oil, LOT-vibration isolation pads. LOT-Thermometer for water inlet and outlet and water flow switches. MCCB's as a part of the chiller. Copper cable & isolators for chiller to be included in the chiller cost. Chiller shall be ASME U stamped and VFD shall be IEEE519 complied. Compressor, condenser and evaporator shall be manufactured by OEM itself.

4

-

-

... More
Pumps and Cooling Tower

-

-

-

... More
Supply, installation, testing & commissioning the chilled water primary pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Mechanical efficiency of Pump shall be minimum 75% as per ECBC + Buildings 2017 and motor efficiency shall be minimum IE3. Capacity: 408 USgpm, 1440 RPM (Suggested), Head: 45 feet.

5

-

-

... More
Supply, installation, testing & commissioning the chilled water secondary pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Mechanical efficiency of Pump shall be minimum 75 % as per ECBC + Buildings 2017 and motor efficiency shall be minimum IE3. Capacity : 408 USgpm, 1440 RPM (Suggested), Head : 90 feet.

5

-

-

... More
Supply, Installation, Testing & commissioning of Variable Frequency Drive complete IP 20 VSPS control panel (IP 55 if panel is to be installed under open air) consisting of adjustable frequency drive (AFD) for each pump, one dedicated microprocessor based pump controller per zone housed within this enclosure panel with parallel pumping software duly down loaded and differential pressure sensor / transmitters as per the site requirement. The entire system along with secondary pumps as described above must be sourced from single manufacturer only, to ensure unit responsibility. The VFD should be incorporated with RFI (radio frequency interface) filters which can control THDi complying to IEEE519 standards, auto bypass starter compactable to the third party BMS.

1

-

-

... More
Supply, Installation, testing & commissioning the condenser water pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Mechanical efficiency of pump shall be 75% as per ECBC + Buildings 2017.Motor efficiency shall be minimum IE 3. Capacity: 680 USgpm, 1440 RPM (Suggested), Head: 70 feet.

5

-

-

... More
Supply, Installation, testing & commissioning the cooling towers as per specification including all accessories as specified and as required. COOLING TOWERS of actual capacity complete in all respects as per technical specifications and equipment schedule complete with FRP casing, FRP fan cylinder, PVC louvers, PVC drift eliminator polypropelene nozzles, drive assembly, HDG fan guard/bird screen, non-clogging nozzle type water distribution system. PVC fill, GI ladder, make up water, quick fill, drain over flow connections etc. as per specifications. Including R.C.C foundation along with PCC/RCC sub base, fixing with bolts and nuts and finishing the slabs or any opening, Control panel, VFD etc. VFD shall operate with sensing the temperature difference from inlet and outlet of the cooling tower. Cooling towers shall meet or exceed the minimum efficiency requirements specified for ECBC+ buildings.170 TR - CTI/JCI approved induced draft, cross flow cooling tower with vertical air discharge. EWT = 97.5 degree F LWT = 90 degree F WET bulb = 82 degree F Flow rate = 680 USgpm Fan Motor Efficiency : IE 3, VFD DRIVEN

4

-

-

... More
Double Skin Air-Handling Units with VFD, Plug Fans and Thermal Break

-

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same.24 TR, 9600 cfm, 19.2 sqft./ 4row (Double Skin floor mounted Horizontal unit with mixing box)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same.22 TR, 8800 cfm, 17.6 sqft./ 4row (Double Skin floor mounted Horizontal unit with mixing box)

2

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same.20 TR, 8000 cfm, 16 sqft./ 4row (Double Skin floor mounted Horizontal unit with mixing box)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same.18 TR, 7200 cfm, 14.4 sqft./ 4row (Double Skin floor mounted Horizontal unit with mixing box)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 17 TR, 6800 cfm, 13.64 sqft./ 4row (Double Skin floor mounted Horizontal unit with mixing box)

2

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 12 TR, 4800 cfm, 9.6 sqft./ 4 row (Double Skin floor mounted Horizontal unit with mixing box)

2

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same.10 TR, 4000 cfm, 8 sqft./ 4 row - (Double Skin floor mounted Horizontal unit with mixing box)

2

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 8 TR, 3200 cfm, 6.4 sqft./ 4row (Double Skin floor mounted Horizontal unit with mixing box)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same.7 TR, 4200 cfm, 8.4 sqft./ 4row (Double Skin floor mounted Horizontal unit with mixing box, 2 x 3 KW Heater)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same.6 TR, 2400 cfm 4.8/ 4 row. (Double Skin floor mounted Horizontal unit with mixing box)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 5 TR, 2000 cfm 4 sqft / 4 row. (Double Skin floor mounted Horizontal unit with mixing box)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 4 TR 1600 cfm 3.2 sqft / 4 row. (Double Skin floor mounted Horizontal unit with mixing box)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 3 TR 1200 cfm 2.4/ 4 row. (Double Skin floor mounted Horizontal unit with mixing box)

2

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 10 TR, 4000 cfm, 8 sqft./ 4 row - (Double Skin ceiling suspended AHU with mixing box)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 5 TR, 2000 cfm 4/ 4 row. (Double Skin ceiling suspended AHU with mixing box).

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same.14 TR, 5600 cfm, 11.2 sqft./ 4 row - (Double Skin floor mounted Horizontal unit with fine filte and mixing box & Ultraviolet Germicidal Irradiation lamp].

6

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same.13 TR, 5200 cfm, 10.4 sqft./ 4 row - (Double Skin floor mounted Horizontal unit with fine filte ,mixing box & Ultraviolet Germicidal Irradiation lamp.

2

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 11 TR, 4400 cfm, 8.8 sqft./ 4 row - (Double Skin floor mounted Horizontal unit with fine filter, mixing box & Ultraviolet Germicidal Irradiation lamp.

6

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 9 TR, 3600 cfm, 8 sqft./ 4row (Double Skin floor mounted Horizontal unit with fine filte and mixing box)

1

-

-

... More
Supply, Installation, testing & commissioning the following Air Handling Units as per specification including all accessories as specified and as required for complete installation. The cost inclusive of VFD starter panel in a separate enclosure with necessary rating incomer isolator / MCCB /contactor with by-pass starter system with all accessories including necessary connections, inter connections and control wiring with pressure sensors (minimum 2 Nos.) for complete installation. Only HVAC application VFD's shall be used. All AHU's will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. AHU fan efficiency shall be as per ECBC + Buildings 2017. AHU shall be Pre-Plasticised Sheet/powder coated, Extruded Aluminium penta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. IE-3 efficiency TEFC sq.cage induction motor of required rating including mounting and fixing arrangements. Plug fan with VFD Drives anti vibration springs/isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 20 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU. Balance will be measured in the chilled water piping.Thermostat, Thermo well at the inlet and outlet of cooling coils, gauge cocks at the the inlet and outlet of cooling coils for pressure gauges, duct damper, including Control wiring to make M/V in close position while AHU is OFF with relays etc. Limit switch in door and inspection lamps to be fixed. Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the AHU cost. Fixing with bolts and nuts and finishing the slabs or any opening etc. as good as same. 13 TR, 5600 cfm, 11.2 sqft./ 6 Row -Double Skin Floor mounted Horizontal AHU with mixing box, Fine filter ).

1

-

-

... More
TREATED FRESH AIR UNIT WITH HEAT RECOVERY WHEEL, VFD, SUPPLY & RETURN FANS-Supply at site, including, local transport, unload, store, handle, erect, balancing, testing and commission of the entire HRW as per specifications including all accessories as specified and as required. Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F Return Air condition: DBT- 75 Deg F , RH– 55% Supply Fan Static - 60 to 70 mm WG Return fan - 40 mm to 60 mm WG Efficiency 80- 85% TFA - 20 TR HRW AHU, 6.6 sq.ft./ 8 Row coil with 3300 CFM Supply fan, 3000 CFM Return fan and heater capacity of 2 x 3KW.

1

-

-

... More
Supply, installation, testing and commissioning of IN-DUCT UV -C technology-based Air Disinfection system designed to improve indoor air quality and to disinfect supply air, confirming to the specification and dosage criteria set by CSIR -CSIO, Govt India and ASHRAE. (11 TR 4400 CFM-6Nos., 13 TR-5200 CFM-2Nos.,14 TR 5600 CFM-6Nos.)

14

-

-

... More
Fan Coil Units and VAV

-

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage IE 3 rated induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF). 1 TR Hideway FCU.

10

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage IE 3 rated induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF). 1.25 TR Hideway FCU.

48

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage IE 3 rated induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF). 1.5 TR Hideway FCU.

20

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage IE 3 rated induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF). 2 TR Hideway FCU.

31

-

-

... More
VAV (Variable Air Volume)Vav unit for supply air OF rectangular ducts with thermostats and controls Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate.Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 2100 cfm

2

-

-

... More
VAV (Variable Air Volume)Vav unit for supply air OF rectangular ducts with thermostats and controls Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate.Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 2000 cfm

1

-

-

... More
VAV (Variable Air Volume)Vav unit for supply air OF rectangular ducts with thermostats and controls Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate.Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 1450 cfm

1

-

-

... More
VAV (Variable Air Volume)Vav unit for supply air OF rectangular ducts with thermostats and controls Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate.Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 1350 cfm.

1

-

-

... More
VAV (Variable Air Volume)Vav unit for supply air OF rectangular ducts with thermostats and controls, Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate.Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 800 cfm

1

-

-

... More
Chilled Water Piping and Valves

-

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C' class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 200mm dia. (75mm thick expanded polysterene) - 250 mm dia.

175

-

-

... More
16.3.5 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 200mm dia. (75mm thick expanded polysterene)

260

-

-

... More
16.3.6 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 150mm dia. (50mm thick expanded polysterene)

50

-

-

... More
16.3.7 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of Nominal size - 125mm dia. (50mm thick expanded polysterene)

50

-

-

... More
16.3.8 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (50mm thick expanded polysterene)

100

-

-

... More
16.3.9 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 80mm dai. (50mm thick expanded polysterene)

120

-

-

... More
16.3.10 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 65mm dia.(50mm thick expanded polysterene)

580

-

-

... More
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)

880

-

-

... More
16.3.12 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 40mm dia. (50mm thick expanded polysterene)

500

-

-

... More
16.3.13 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 32mm dia. (50mm thick expanded polysterene)

550

-

-

... More
16.3.14 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 25mm dia. (50mm thick expanded polysterene)

1050

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C' class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 20mm dia. (50mm thick expanded polysterene)

2100

-

-

... More
Site fabricated pipe (MS class C) with adequate structural support and with PUF injection insulation & AL cladding for part plant room & AHU room area and valve insulation with openable boxing for inspection.125 mm dia.

150

-

-

... More
Site fabricated pipe (MS class C) with adequate structural support and with PUF injection insulation & AL cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection. 250 mm dia.

85

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 32 mm dia. PVC

10

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 25 mm dia. PVC

200

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. 20 mm dia. PVC

500

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation: Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 250 mm dia.

5

-

-

... More
16.7.1.1 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 200 mm

2

-

-

... More
16.7.1.2 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 150mm

2

-

-

... More
16.7.1.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 125 mm

28

-

-

... More
16.7.1.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 80 mm

10

-

-

... More
16.7.1.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 65 mm

16

-

-

... More
16.7.1.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 50mm

36

-

-

... More
16.7.1.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 40 mm

50

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation: Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven. 100 mm dia.

6

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation: Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven.32 mm dia.

31

-

-

... More
Supply, installation, testing & commissioning of the following type forged Ball Valve, PN-20 gunmetal /cast alloy, including all necessary accessories and connections. 25 mm dia

126

-

-

... More
Supply, installation, testing & commissioning of the following type forged Ball Valve, PN-20 gunmetal /cast alloy, including all necessary accessories and connections. 20 mm dia

76

-

-

... More
16.7.2.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility of 125 mm dia

4

-

-

... More
16.11.2.3 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Non- Return Valve with dual plate of C I body S S plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.Non- Return Valve of 125 mm dia

14

-

-

... More
SUCTION GUIDE with strainer: Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required. Size: 125 mm dia.

14

-

-

... More
16.7.4.6 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified Y- Strainer of 65 mm dia

1

-

-

... More
16.7.4.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified Y- Strainer of Ductile of 50 mm dia

16

-

-

... More
16.7.4.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified Y- Strainer of 40 mm dia

20

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified Y- Strainer of 32 mm dia

4

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified Y- Strainer of 25 mm dia

3

-

-

... More
16.8 : Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

116

-

-

... More
'THERMOMETERS - For chiller, pumps, AHU: Supply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification.

116

-

-

... More
Supply, installation, testing & commissioning of differential pressure switch as per the specifications and as required.

4

-

-

... More
16.11.3.6 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.125mm dia

4

-

-

... More
500 L Pressurized Tank: Design, supply, installation, testing and commissioning of Pressurised chilled water expansion tank with Make up connection for closed loop system along with necessary pneumatic devices and accessories and MS 'C' section supports in order to keep chilled water under pressure.The tank shall be precharged steel tank with replacable heavy duty butyl rubber bladder.The tank shall have 50mm system connection and 20mm drain and charging valve connection to facilitate on-site charging of tank.The tank shall be fitted with lifting rings and floor mounting skirt for vertical installation.The tank shall be constructed according to section 8 of ASME boiler and pressure vessel code and stamped 125psi working pressure.The contractor shall submit calculation regarding the above data. Pumps shall be of N+1 configuration. including with control wiring.

1

-

-

... More
Supply, installation, testing & commissioning of a common air separator on the chilled water return line located at the pump suction and suitable for Secondary pump water flow; the separator shall be complete with high capacity air vent, flanges, service valve, non return valve, isolation butterfly valve for makeup water inlet. Capacity suitable for 1428 USGPM and 250 mm NB CHW Header line.

1

-

-

... More
AUTO AIR VENTS including Ball Valves: Supply & install of airvents / purge valves including 15mm Ball Valves at the highest points in chilled water piping complete each floor with pipes nipple welded to pipe, hex nipple, socket, U-pipe connection at outlet of air vent etc. as required.

56

-

-

... More
Supply and fix flexible connections with control rods for pumps and chiller. Size: 125 mm dia.

28

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type). 65 mm dia.

1

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type). 50 mm dia.

16

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type). 40 mm dia.

20

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type). 32 mm dia.

4

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type). 25 mm dia.

3

-

-

... More
Condenser Water Piping and Valves

-

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specifications. Opening as good as same.300 mm dia.

240

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same. 200 mm dia.

160

-

-

... More
16.11.1.1 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedBUTTERFLY VALVE (MANUAL) 200 mm

26

-

-

... More
16.11.2.1 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Non- Return Valve with dual plate of C I body S S plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.Non- Return Valve of 200 mm dia

5

-

-

... More
Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required Size: 200 mm dia

5

-

-

... More
Supply and fix flexible connections with control rods for pumps, cooling tower & condenser. Size: 200 mm NB

18

-

-

... More
Supply, installation, testing & commissioning of Balancing Valve, with built in measuring facility with C.I Body, 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections;Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/- Size: 200 mm NB

8

-

-

... More
THERMOMETERS - For chiller, pumps, AHU: Supply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

18

-

-

... More
PRESSURE GAUGE - For chiller, pumps, AHU: Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type,made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection : Brass, NPS 12mm dia bottom-outlet type, Dial: Satin-faced, non-reflective aluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

18

-

-

... More
16.8 : Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

18

-

-

... More
16.11.3.4 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.200mm dia.

8

-

-

... More
Ducting, Grills, Diffuser and Insulation

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

3850

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

3300

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

250

-

-

... More
16.12.1.4 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

5

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major & Minor OT's, CT/MRI, Bunker, Cath Lab etc. Thickness 0.80 mm Al. Sheet ducting

150

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major & Minor OT's, CT/MRI, Bunker, Cath Lab etc. Thickness 1.00 mm Al. Sheet ducting

100

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major & Minor OT's, CT/MRI, Bunker, Cath Lab etc. Thickness 1.25 mm Al. Sheet ducting

20

-

-

... More
Supply installing, testing and commissioning of (Factory Fabricated) HEPA filters of efficiency 99.9% down to 0.3 microns in filter plenum of 18 Gauge with rubber Gaskets In SS suitable frame work with 70% perforated grille 'TOTAL HEPA FILTRATION AREA - 5.4 Sq.mt: Ultra Clean Ventilation arrangement of A/C inside the Lab comprising of SS supply plenum including the 1.5'' flanges on all sides., material SS 304, 0.8mm, 2B finish. HEPA filters 0.3microns, efficiency 99.97% EU13 Sizes of - 1200X900X150 - 4 Nos, 900 x 600 x 150mm- 2 Nos. The HEPA filters will be fixed to the plenum using M6 SS rode, 304 Q type SS bolts and nuts). SS perforated sheets Mat finish. Hepa filters (550 cfm x 4 nos.+ 500 x 2 Nos.)

6

-

-

... More
Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

6

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

4

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600X600 SD: 225 x 225

12

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600X600 SD: 300 x300

630

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600X600 SD: 375 x375

88

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 RD: 225 x225

12

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 300 x300

670

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 SD: 375 x375

100

-

-

... More
Supply installing, testing and commissioning of perforated aluminium grille for return with VCD and 10 Micron Filter in OT

20

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification. 300 mm dia

400

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification. 350 mm dia

75

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 300X300X350H

12

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 350X350X400H

630

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 450X450X400H

88

-

-

... More
SITC of Factory made fresh air dampers with louvers and control lever, filter etc as required. (as per drawing)

55

-

-

... More
SITC of Factory made fresh air dampers having 20 micron filter with louvers and control lever. (for OT as per drawing)

1

-

-

... More
Supply, fix, balance and commissioning of louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, brass bushings complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges, fixing arrangement etc, as per specifications. Al. volume control duct damper

26

-

-

... More
Supply and fix 1 1/2 hour fire rated fire dampers air ducts (main line) with fusible link & micro switch to shut of corresponding AHU (including control cable.)

35

-

-

... More
Supply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140-180kg/m3

1000

-

-

... More
Non-AC Area insulation - Supply & fixing of 19 mm thick Class O nitrile rubber insulation with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3. Moisture Diffusion Resistance Factor of the base insulation material shall be minimum 10,000, thermal conductivity shall be 0.033 W/mk. R value of the insulation material shall comply with the ECBC + building standards.

2900

-

-

... More
Supply & fixing of 19 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3. Moisture Diffusion Resistance Factor of the base insulation material shall be minimum 10,000, thermal conductivity shall be 0.033 W/mk. R value of the insulation material shall comply with the ECBC + building standards

4600

-

-

... More
Ventilation System

-

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 4500 cfm Exhaust Blower

2

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 2750 cfm Exhaust Blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 2200 cfm Exhaust Blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 1700 cfm Exhaust Blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 1600 cfm Exhaust blower

4

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 1500 cfm Exhaust blower

1

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 1350 cfm Exhaust blower

16

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 1100 cfm Exhaust blower

3

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 1000 cfm Exhaust blower

5

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 900 cfm Exhaust blower

6

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 850 cfm Exhaust blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 800 cfm Exhaust blower

3

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 700 cfm Exhaust blower

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 650 cfm Exhaust Blower

7

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 600 cfm Exhaust Blower

4

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 500 cfm Exhaust Blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 450 cfm Exhaust Blower

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 400 cfm Exhaust Blower

7

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 350 cfm Exhaust Blower

19

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 300 cfm Exhaust Blower

32

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 250 cfm Exhaust Blower

3

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 200 cfm Exhaust Blower

14

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 150 cfm Exhaust blower

59

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 100 cfm Exhaust blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 80 cfm Exhaust blower

47

-

-

... More
Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work with fan section TEFC sq.cage induction motor of required rating including mounting and fixing arrangements DIDW Centrifugal fan and motor pulley,V-belts and belt guard., and anti vibration sprinds/ isolator bearings etc Insulation of all section with fire retardant insulation material as per manufactures standard.Accessories such as:Double canvas connections of fire retardant quality for connecting unit to ducting/plenum.Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any Opening etc Motor efficency , IE 3 : Exhaust fans 12500 cfm Exhaust blower with AIR WASHER WATER BASE (100 mm static)

1

-

-

... More
Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work with fan section TEFC sq.cage induction motor of required rating including mounting and fixing arrangements DIDW Centrifugal fan and motor pulley,V-belts and belt guard., and anti vibration sprinds/ isolator bearings etc Insulation of all section with fire retardant insulation material as per manufactures standard.Accessories such as:Double canvas connections of fire retardant quality for connecting unit to ducting/plenum.Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any Opening etc Motor efficency , IE 3 : Freshair fan 11000 cfm fresh air Fan for Kitchen (50 mm static)

1

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

1000

-

-

... More
Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification Size: 100mm dia.

900

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

10

-

-

... More
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers.SIZE :150 X 150 MM Exhaust Grill

900

-

-

... More
Additional Works

-

-

-

... More
Automatic type Chemical dosing system, for condenser water piping system(contious treatment) as per specification and drawing.Total package of flushing, chemical pre-cleaning, passivation and treatment with chemicals etc. with necessary permanently installed equipment's and its controls. This package includes initial analysing of make up water sample. Then programming methods and duration. Accordingly, supply, install, tesingt commissioning and maintain for a specified period with dosing pumps , tanks, water meters corrosion coupon tanks, valves with required chemicals and its micro-processor based controller with program etc. as per specification. Maintaining the clean piping system without corrosion, scale or micro-biological activity for an optimum operational efficiency and handing over the entire system in a healthy condition at the end of contrat. which is the suppliers responsibility.Cost for supply of chemicals required for 3 years (contact period) passivation to be considered.

1

-

-

... More
Initial Chemical treatment , for chilled water piping system with necessary temporarily installed equipment's - one time flushing, chemical pre-cleaning passivation with suitable chemicals. to make chilled water free of corrosion, scale or micro-biological activity for an optimum operational efficiency and handing over the entire system in a healthy condition at the end of the contract which is the suppliers responsibility.

1

-

-

... More
UNDER DECK INSULATION - Supply & fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3

6500

-

-

... More
Roof(inside) insulation for exposed slabs/walls : Supply & fixing of 12 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3.

525

-

-

... More
Electrical Work

-

-

-

... More
AHU PANEL - 1 supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 63 A, FP, MCCB Isolator. 63 A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL , Thermal Magnetic release MCCB - 4 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos

1

-

-

... More
AHU PANEL - 2 Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 120A, FP, MCCB Isolator - 1 No. 120A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 13 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 2 nos.

1

-

-

... More
AHU PANEL - 3 Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 3 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos

1

-

-

... More
AHU PANEL - 4 Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 80A, FP, MCCB Isolator - 1 No. 80A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 6 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos

1

-

-

... More
AHU PANEL - 5 - Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 63 A, FP, MCCB Isolator - 1 No. 63 A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh. RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 5 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos

1

-

-

... More
AHU PANEL - 6 - Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 3 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos.

1

-

-

... More
AHU PANEL - 7 -Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 32A, FP, MCCB Isolator - 1 No. 200A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 3 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos.

1

-

-

... More
Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 63A, FP, MCCB Isolator - 1 No. 63A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 4 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos.

1

-

-

... More
Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads . The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 100 A, FP, MCCB Isolator - 1 No. 100 A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 8Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos.

1

-

-

... More
Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads. The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 80 A, FP, MCCB Isolator - 1 No. 80 A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 7 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos.

1

-

-

... More
Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads. 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads. The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 100 A, FP, MCCB Isolator - 1 No. 100 A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 8Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 1 nos.

1

-

-

... More
Supply, Conveyance, Installation, Testing and Commissioning of self-supported, free standing powder coated cubicle type CRCA No.14/16 gauge sheet construction with cable entry facility at top and bottom, cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads . 2 A SP MCB shall be mounted on DIN rail. Doors shall be provided with 4 sq.mm flexible copper earth leads. The main earth bus shall be of size adequate size copper and run through the switch board for earthing metallic parts of switch gear s. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters. The panel details are listed below. All panels must be BMS compatible. The type of construction of panels must be form 4A. Incomer - 160 A, FP, MCCB Isolator - 1 No. 100 A 433V, 25kA, best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Necessary interlocking arrangement. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh RYB phase indicating LED lamps with control fuses and switches - 1 Set. Outgoings 25A, 16kA, TP+NL, Thermal Magnetic release MCCB - 13 Nos. 25 A, 16kA, TP+NL, Thermal Magnetic release MCCB - Spare 2 nos

1

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 4CX6 Sq.mm Al Cable

30

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 4CX4 Sq.mm Al Cable

2100

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3.5CX 70 Sq.mm Al Cable

20

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3CX6 Sq.mm Al Cable

510

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) amended upto date. 3CX4 Sq.mm Al Cable

600

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 3 core x 1.5 sq mm copper Armoured Control cable

390

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 2 core x 1.5sqmm copper Armoured Control cable

125

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) ammended upto date. 6 core x1.5 sq mm copper Armoured Control cable

350

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

4125

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4CX6 Sq.mm Al Cable

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4CX4 Sq.mm Al Cable

130

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3CX6 Sq.mm Al Cable

40

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3CX4 Sq.mm Al Cable

36

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 3C X 1.5 sq. mm

38

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 2C X 1.5 sq. mm

12

-

-

... More
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 6C X 1.5 sq. mm

218

-

-

... More
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant. Copper wire No.10 SWG

1500

-

-

... More
Supply and laying the following sizes of earthing bare copper/strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc. as required for complete installation as instructed by engineer in charge/consultant. Copper wire No.8 SWG

200

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)

100

-

-

... More
90.16.3.10 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)

60

-

-

... More
Supplying and fixing of FP 25/32/40amps 415 volts 'C' curve FP MCB with sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required.

4

-

-

... More
supply and fixing of lockable off push button near pumps and Cooling Tower. Material shall be thermoplastic with minimum IP 65 rating.

19

-

-

... More
Building Management System

-

-

-

... More
Central core Computer - PC (Intel i7 Processor), 8 GB RAM, 2 GB Graphics card, DVD Writer, 22' LED monitor, 1 TB HDD, Microsoft mouse, Keyboards, 2 serial, 1 parallel port/KB, Windows 8 operating system, antivirus software

1

-

-

... More
A4 Colour Laser printer

1

-

-

... More
System Controller to interface field level controllers to IBMS Workstation Supply, Installation, Testing and Commissioning of Building Management System Graphic User Interface software with 3 user client license, user groups, user profiles and scopes, alarm handling, scheduling, trending, reporting engine, database system, system activity log, historical data management, real time zoom enabled vector graphics, system backup and restore, HTML based documentation and help, SMS/Email facility complete in all respects as per tender specification. Graphical Software complete to cater to hardware points as specified in the Data Point Summary as well as Third Party Software Integrated Systems. Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Chiller System - (50 points/chiller)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Secondary Pumps System (10 Points/Pump)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BacNET shown on BacNET explorer) Variable Frequency Drives for AHU's (10 Points per VFD)

1

-

-

... More
Networkable DDC Controllers as per Data Point Summary (1- 5) with enclosure with all necessary wiring and accessories

1

-

-

... More
Immersion Type Temperature Sensor

4

-

-

... More
Level Switch for expansion tank ( 2 point) (depth of tank - 1 mtr.)

1

-

-

... More
Differential Pressure Switch

8

-

-

... More
Level Switch for cooling tower

3

-

-

... More
Controls for Chiller System: Outside Air Temperature & RH Sensor

1

-

-

... More
Differential Pressure Sensor

1

-

-

... More
Air Handling Units - : Supply, Installation, testing & commissioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC

12

-

-

... More
Air Handling Units Supply, Installation, testing & commissioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC.

20

-

-

... More
Supply, Installation, testing & commissioning of Differential Pressure Switch across filter

21

-

-

... More
Supply, Installation, testing & commissioning of Return air Temperature Sensor

44

-

-

... More
Supply, Installation, testing & commissioning of RH Sensor Room type.

10

-

-

... More
Supply, Installation, testing & commissioning of Differential Pressure Switch across filter- Pre filter, fine filter as required

32

-

-

... More
Supply, Installation, testing & commissioning of Differential Pressure Switch across filter- Pre filter, fine filter and Hepa filter as required

21

-

-

... More
Supply, Installation, testing & commissioning of Air Differential Pressure sensor

7

-

-

... More
SITC of Signal Cabling - 2 Core 1.0 sq.mm. shielded FRLS armoured cable

3000

-

-

... More
SITC of Signal Cabling - 4 Core 1.0 sq.mm. shielded FRLS armoured cable

4900

-

-

... More
SITC Signal Cabling - 8 Core 1.0 sq.mm. shielded FRLS armoured cable

1500

-

-

... More
SITC of Communication Cabling - 2 Core 1.5 sq.mm. shielded FRLS armoured cable or CAT5E armoured cable

1600

-

-

... More
SITC of Power Cable - 3 C X 2.5 SQMM -ATC Armoured Cable

800

-

-

... More
SITC of Cable tray 150 x 150 mm

200

-

-

... More
Supplying and installing following size of pre galvenised iron floor race way including cover, GI bolts & nuts, etc. as required

150

-

-

... More
Sub head 5 - Fire Protection Works Fire Pump Room Equipment

-

-

-

... More
MAIN PUMP - Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(b) Suitable HP Squirrel cage inductionmotor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, ACsupply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads. Capacity: 2850 LPM at 88 Meter Head, and High efficient IE-3 rated.

1

-

-

... More
SPRINKLER PUMP - Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(b) Suitable HP Squirrel cage inductionmotor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, ACsupply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Suitable cement concrete foundation duly plastered with anti vibration pads. Capacity: 2850 LPM at 88 Meter Head, and High efficient IE-3 rated.

1

-

-

... More
DIESEL PUMP - Supplying, installation, testing and commissioning of diesel engine driven main firepump suitable for automatic operation and consisting of following, complete in all respects, as required :(Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator,diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. Capacity: 2850 LPM at 88 Meter Head.

1

-

-

... More
JOCKEY PUMP -Supplying, installation, testing and commissioning of electric driven pressurizationpump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.Suitable HP squirrel cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS : 325.M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. Capacity: 180 LPM at 88 Mtrs. Head, IE-3 rated..

2

-

-

... More
Supply, erection, commissioning of additional length of Exhaust Pipes with long radius bend from silencerwith necessary clamps, fixtures, civil works andthermal insulation with 50 mm thick glass wool and with 1.0 mm thick aluminium sheet cladding of following adequate size including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. The horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust..

55

-

-

... More
MOTOR CONTROL PANEL - MOTOR CONTROL PANEL - Fabrication, supply, Insallation testing & commissioning of Electrical controlpanel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet,compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : The Panel shall be comply IS standard. Main Fire Pump - 1 No. Sprinkler Pump - 1 No.Jockey Pump - 2 Nos. Incomer - 630A, FP, MCCB Isolator - 1No. 630A, 415V, 36 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh. Class B + C / Class 1 + 2 Surge arrestor device with necessary MCCB for protection of same - 1 Set. RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoing- 250A, TP+NL, MCCB Isolator + Star delta starter with all accessories Without overload relays / protection - 2 Set. 32A, TP+NL, MCCB Isolator + DOL Starter with all accessories with overload realy and single phase preventor - 2Set.

1

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 250 mm dia.

40

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 200mm.

36

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150mm.

45

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100mm.

5

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 80mm

10

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65mm .

5

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50mm.

20

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 25mm

30

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16,conforming to IS: 13095 with required companion flanges nuts, bolts etc. complete.250mm.

1

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16,conforming to IS: 13095 with required companion flanges nuts, bolts etc. complete150mm .

3

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required:80mm dia

2

-

-

... More
Providing, fixing, testing and commissioning of Vertical Check Valve of Bronze Construction, PN:25, single piece design with Integral Seat and with features as detailed in the Technical Specifications.Dia - 50mm.

2

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :Dia - 200mm.

4

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :Dia - 150mm

10

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :80 mm dia

4

-

-

... More
Providing, fixing, testing and commissioning of Ball Valve, PN-25 Forged Brass & Nickel / Chrome Plated, conforming to IS: 9890 with Screwed Female Ends to BS:21, and with non-corrosive handle / lever, all as per Technical specification. including necessary accessories and connections. Dia - 50mm.

2

-

-

... More
Providing, fixing, testing and commissioning of Ball Valve, PN-25 Forged Brass & Nickel / Chrome Plated, conforming to IS: 9890 with Screwed Female Ends to BS:21, and with non-corrosive handle / lever, all as per Technical specification. including necessary accessories and connections. Dia - 25mm.

8

-

-

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.Dia - 150mm.

1

-

-

... More
Providing, installing and commissioning of C.I.flanged 'Y' type Strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete. Dia - 250mm .

3

-

-

... More
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12, Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 250mm .

7

-

-

... More
Supply, Installation of Flow metre (Electronic type) on Test line to measure 150 % of pump flow and CI butterfly valves as per BS 5155 ( PN 16) slim seal standard lever operated type with required flanges, nuts, bolts etc. complete. Dia - 150mm .

1

-

-

... More
Supply, Installation,testing,and commissioning of air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

1

-

-

... More
Supply, installation, testing and commissioning of Heavy Duty Neoprene Expansion Joints / Flexible Connectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories.Dia - 150mm.

3

-

-

... More
Supply, installation, testing and commissioning of Heavy Duty Neoprene Expansion Joints / Flexible Connectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories.Dia - 80mm.

4

-

-

... More
Supply, installation, testing and commissioning of Heavy Duty Neoprene Expansion Joints / Flexible Connectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories.Dia - 200mm

3

-

-

... More
Supply, installation, testing and commissioning of Pressure Switches with pressure rating 4 to 14 Bar with a differential of 0.2 to 1.6 Bar (however; should be suitable for Fire Pumps) and with 1/14" BSP (F) inlet connection and screwed cable entry for fixing cable gland. It shall also be complete with Stainless Steel Isolation Cock, Nipples, tail, connecting pipes etc, as per Technical Specifications.

6

-

-

... More
Supply, installation, testing and commissioning of 4' dia. Bourdon Type Pressure Gauge, with ISI Mark or of equivalent International Standards.Weather / Water Proof Type, Pressure Range: 0 to 16 Bar, with Stainless Steel Shut off Cock, Syphone Pipe, Snubber etc.

5

-

-

... More
Hydrant System

-

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150mm.

1570

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100mm.

353

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80mm.

740

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :65mm .

350

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50mm .

1110

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :40 mm dia.

1860

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :32 mm dia.

2520

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25mm .

4345.36

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 200 mm dia.

140

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150mm

335.66

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100mm

6

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 80mm

95

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia.

52

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia.

1

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :Dia - 150mm.

1

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel

10

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304)

114

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304)

57

-

-

... More
Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided /rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm dia isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set.

56

-

-

... More
Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30'' x 24'' x 10'' size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement.

57

-

-

... More
Supplying, installing and commissioning of fire brigade draw-out connection of 2 way with 2 nos. 63 mm dia. outlet arranged on 100 mm dia. Pipe manifold and connected to Fire water tank. Quoted rate shall be included with C.I. Butterfly valve, foot valve and M.S. cabinet of suitable size with mounting supports etc. complete.

3

-

-

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel.

10

-

-

... More
Supply and fix at site in position Weather Proof Fire Hose Cabinet, wall / pole mounting type, 30'' x 24'' x 10'' size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and pole for mounting, all as per requirement.

10

-

-

... More
Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including necessary accessories and connections.

11

-

-

... More
Providing, fixing, testing and commissioning of Ball Valve, PN-25 Forged Brass & Nickel / Chrome Plated, conforming to IS: 9890 with Screwed Female Ends to BS:21, and with non-corrosive handle / lever, all as per Technical specification. including necessary accessories and connections. Dia - 40mm.

31

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories:Pendant sprinkler.

3263

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories:Upright sprinkler.

3377

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories:Horizontal side wall sprinkler.

5

-

-

... More
Providing, Fixing, Testing and Commission Flexible Sprinkler Hose; UL Listed/FM Approved, 25mm. (1') BSP Male Inlet, 15mm. (1/2') NPT Female Outlet, Braided, Working Pressure 13.8 Bar, length: 1000 mm, and with all connecting systems and accessories.

1500

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 20 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System. The control cabling from flow switches to Fire Sprinkler Annunciating Panel shall be measured separately

31

-

-

... More
Supply, installation, testing and commissioning of Hydraulically Operated Fire Sprinkler Alarm Valve (Installation Control Valve), Grooved End, UL Listed / FM approved, complete with Constant Pressure Trim Assembly, Water Motor Gong, control valves, pressure switch, pressure gauges etc. including all necessary fixing accessories.150mm. Size.

2

-

-

... More
Providing, Fixing, Testing and Commission Flexible Sprinkler Hose of adequate size; UL Listed, FM Approved, 25mm. (1") BSP Male Inlet, 15mm. (1/2") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, length: 1500 mm, and with all connecting systems and accessories.

500

-

-

... More
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

3282

-

-

... More
Supply, installation,testing and commissioning of Fire duct Shutter fabricated out of M.S.sheet and frame, door shall be 900mm x 1200 mm150 mm depth min. & fixed with 4 mm thick Glass, suitable Rubber beading and Locking arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder coated of approved colour both inside and out side.

57

-

-

... More
Supplying, installing and commissioning of fire brigade inlet inlet connection of 4 way with 4 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main as well as to Fire water tank. Qouted rate shall be included with M.S. cabinet (painted - inside and outside) of suitable size with mounting supports etc. complete.

2

-

-

... More
Supply, installation,testing and commissioning of orifice plates; with the following specification - made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

17

-

-

... More
Supply, installation,testing and commissioning of orifice plates; with the following specification - 25 mm dia Orifice plate made out of 8 mm thick stainless steel plate ( in tee off to fire hose reel) for pipe to reduce pressure upto 3.5 Kg/sqcm complete in all respects

15

-

-

... More
Fire Extingushers

-

-

-

... More
ABC powder type fire extinguisher with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc. complete, confirming to IS:15683.6 Kgs.

173

-

-

... More
Co2 type Fire Extinguisher, made from brand new seamless steel cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Wheel type valve with initial Charge and mounted on Rubber Wheels / wall mounted brackets as per IS: 16018 specification, bearing ISI Mark.4.5 Kgs.

34

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.Clean Agent HCFC 123, 4.0 Kg.

1

-

-

... More
Supply, installation, testing & commissioning of Clean Agent Modular Type Fire Extinguisher 5Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with charge of HFC Blend A, It is a blend of Hydro Fluoro Carbon and organic detossificant essence P26. The sprinkler body will comprise of temperature sensitive quartsoid bulb of temperature rating of 68 deg C. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling. Fire Extinguisher manufactured as per BIS 2190 and IS: 15683:2018 and with relevant ISI Stamping/Marking.

84

-

-

... More
Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190and BIS: 15683:2006 and with relevant ISI Stamping/Marking.Foam Type, Cartridge Type, 9 Ltr.

4

-

-

... More
Providing, fixing, commission and install in position .Fire Bucket filled with sand including Fabricated M. S. Stand (Approx. quantity).

5

-

-

... More
Fire Signages

-

-

-

... More
Fire Exit Light - Laser type, with High Glow LED Light, size: 300x150mm or nearby, as per conventionaldesign/colour code panel conforming to IS 9457 Ceiling Mounting type with hanging clamps, on/off switch, Red / Green Colour option, power consumption: 18 Watt or less with all accessories required for complete installation as directed by the engineer inc charge. Power supply shaould be provided with UPS back-up.

155

-

-

... More
Floor Identification Signage ( ie, GROUND FLOOR, FIRST FLOOR, etc.) at each stair enclosure on everyfloor, indicating the floor number in words, of standard size (500x225mm) as per conventional design/colour code on 3mm thick aluminium screws and double tape of hanged from the false ceiling with the help of chain and screws etc. complete as required as per the technical specification.

55

-

-

... More
Signage Printed 'IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE' of 1.25cm.height letters in red with white back ground and standard size (500x225 mm) as per conventional design/colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of screws and double tape or hanged from the false ceiling with the help of chain and screws etc. complete as required as per the technical specification.

56

-

-

... More
Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMPROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) standard size (500x225 mm as per conventional design / colour code on 3 mm thick aluminium composite panel, conforming to IS 9457. The signage will be either fixed on the wall with the help of chain and screws etc. complete as required as per the technical specification.

56

-

-

... More
Supply and installation of photo luminescent glow signage containing standard instructions to the occupants in case of Fire emergency (FIRE ORDER),of standard size (600x800mm minimum) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws and double tape or hanged from the false ceiling with the help of chain and screws etc. complete as required as per the.technical specification.

56

-

-

... More
Supply and fixing (in appropriate location) of Fire emergency evaluation plan (colour) printed in photopaper of size A2 sand -witched in clear acrylic sheets fixed using SS studs and other accessories complete as required as per the technical specification and confirming to IS 9457,IS 12349, IS 12407 Evacuation plan shall be prepared by the contractor and got approved from client/ consultant.

21

-

-

... More
Supply and Fixing of load bearing Fire stop mortar with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards.The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1 g/l as per LEED 2009. Firestop installation should be done by trained applicators and in accordance with manufacturer's guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemical anchoring along the length and breadh of the shaft and provide 2layers of chicken mesh etc.,as the base for fire mortar at 65mm thickness having load bearing capacity of 200kg/sq.mtr, For shaft size more than 0.64 sqmtr proper engineering judgement needs to be submitted through the manufacturer. Applicator needs to submit complete installation report for inspection purpose.

130

-

-

... More
Providing a intumescent, flexible firestop wrap strip for plastic pipe, insulated pipe and various nonmetallic penetrations from 2'' to 6'' diameter. Can be used with orthogonal pipes and pipes at 45°. It is mold and mildew resistant and the performance is Class 0 according ASTM G21-96 and EN ISO 846.Highly intumescent with an expansion temperature (intumescent activation) of 320 deg F (160 deg C) and the expansion ratio up to 1:40. FBC System Compatible. The product shall meet LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 3.1 g/l. Firestop installation should be done by trained applicators and in accordance with Manufacturer guidelines. Applicator needs to provide complete installation report for inspection purpose.Plastic Pipe diameter of 2.5'' (Firestop Wrap),Min. recommended hole dia. in wall/floor: 92 mm..

336

-

-

... More
Providing a intumescent, flexible firestop wrap strip for plastic pipe, insulated pipe and various nonmetallic penetrations from 2'' to 6'' diameter. Can be used with orthogonal pipes and pipes at 45°. It is mold and mildew resistant and the performance is Class 0 according ASTM G21-96 and EN ISO 846. Highly intumescent with an expansion temperature (intumescent activation) of 320 deg F (160 deg C) and the expansion ratio up to 1:40. FBC System Compatible. The product shall meet LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 3.1 g/l. Firestop installation should be done by trained applicators and in accordance with Manufacturer guidelines. Applicator needs to provide complete installation report for inspection purpose Plastic Pipe diameter of 3'' (Firestop Wrap), Min. recommended hole dia. in wall/floor: 112 mm..

336

-

-

... More
Providing Acrylic Firestop Sealant in gaps between periphery of the ducts to provide minimum 2 hours fire rating when subject to the test conditions of UL 2079 standards. The product shall be age tested as per DafStb guidelines. Sealant should provide sufficient MAF, water and gas tight seal. Sealant shall also provide airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation. Sealant shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2- 57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be UL listed & classified and shall bear the UL and FM approval logo on the packing. Firestop installation should be done by trained applicator and in accordance with Manufacturer guidelines. Applicator needs to provide complete installation report for inspection purpose..

8

-

-

... More
Providing expanding fire stop foam with minimum 2 hours fire rating when tested in accordance with UL1479, for horizontal openings in floors or slabs after passing service lines like cable trays or cables/cable bundles. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall carry test certificate for sound insulation of 50 db when tested in accordance with ASTM E 90. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be UL listed & classified and shall bear the UL and FM approval logo on the packing. Fire stop installation should be done by trained applicators and in accordance with Manufacturer guidelines. Applicator needs to submit complete installation report for inspection purpose..

4

-

-

... More
Intelligent Addressable Fire Alarm cum Voice Evacuation System

-

-

-

... More
Supply, installation and testing & commissioning of Microprocessor based Networkable analogue addressable Fire Alarm control Panel. The FACP shall consists of following features & components: .1) FACP shall have 640 Character LCD display, minimum 4000 log history events & QWERTY keypad / touchscreen display for programming..2) Loop Cards - Vendor to decide & indicate based on loop capacity considering 20% spare; including 2 nos additional Loop as spare..3) Network Card (For Peer to Peer Networking).4) BACnet Card ( For integrate with third party systems).5) FACP shall have Adequate no. of Power Supply units for Notification Appliance Circuits for entire project . .6) FACP shall consider adequate no. of Terminal strips for receiving & terminating all external cabling with all internal wiring as required..7) Repeater/mimic connectivity, USB interference with PC etc

2

-

-

... More
Supply, installation and testing & commissioning of GUI based main network software capable of graphically representing each facility being monitored with floor plans and icons depicting the actual locations of the various systems and/ or sensors’ locations. The GUI software shall be located in control room and shall be capable of monitoring fire detectors & devices and operating Digital Voice Evacuation & 2 Way Communication for all the blocks System connected with each other. Software for programming( mapping) the Fire detection and voice alarm system through FACP / Lap top. The software shall consisting with facility like Upload / down load of informations to FACP, Graphics compatible to AutoCAD, Detectors information with change in address / sensitivity etc as required.

1

-

-

... More
Supply, installation, testing and commissioning of analogue Addressable Photo electric smoke detectors (above fasle ceiling) with early response levels, programmable for timed automatic sensitivity selection with base, Back box and other accessories as required and detectors shall be UL/FM listed

1235

-

-

... More
Supply, installation, testing and commissioning of analogue Addressable Photo electric smoke detectors (below fasle ceiling) with early response levels, programmable for timed automatic sensitivity selection with base, Back box and other accessories as required and detectors shall be UL/FM listed.

1238

-

-

... More
Supply, installation, testing and commissioning of addressable Multi-criteria Photo-Thermal Detector.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall be low profile and shall have twin bi-colour LED for 360 deg viewing. The detector shall be UL/FM Listed.

17

-

-

... More
Supply, installation, testing and commissioning of Analogue Addressable Heat sensor detector (fixed temperature) with standard base and fixing accessories. Detectors shall be UL listed.

19

-

-

... More
Supply, installation, testing and commissioning of Response indicator for all detectors located above false ceiling

1212

-

-

... More
Supply, installation, testing and commissioning of Intelligent Addressable Manual Call Station Point with addressable module that monitors and reports contact status, all as per technical Specifications

63

-

-

... More
Supply, installation, testing and commissioning of Addressable Horn cum Strobe wall mounted type rated at 82 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication

96

-

-

... More
Supply, installation, testing and commissioning of Addressable Horn cum Strobe wall mounted type (Weather proof) rated at 82 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication.

2

-

-

... More
Supply, installation, testing and commissioning of Addressable Strobe light wall mounted type rated at 75cd flashing at 1 Hz for visual indication.

17

-

-

... More
Providing, fixing, testing and commission Intelligent Addressable Input / Monitor Module, as per specification for interface with Flow Switches, Fire Pumps, Supervisory Switches, Alarm Valve, Water Tank Level etc.

31

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Control Module, as per specification for interface with Fire Alarm Annunciating System, Lift Panels, Public Address System etc.

131

-

-

... More
Providing, fixing,, test and commission Intelligent Addressable Relay Module, as per specification for interface with AHUs, Ventilation System, Smoke Management System, LPG System, Power Distribution etc. (This quantity shall be tentative / approximate only, shall change as per final design of the other systems and final requirement)

27

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected, all as per technical specifications.

152

-

-

... More
Supply, laying, testing and commissioning of 2Core x 1.5 mm2 FRLS Armoured Cables with Red Colour / Finish, as per Technical Specifications.

13030

-

-

... More
Supply, installation, testing and commissioning of PC with Intel i5, 12 th generation processor, with minimum 8GB RAM, 1 TB Hard disk, Full HD, 21' monitor, keyboard, optical mouse, standalone 1kVA UPS with built in batteries( Min. 45 minutes back-up),desk-jet ink printer cum scanner( all in one, colour) other accessories as required as complete etc.

1

-

-

... More
4.6.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.225 mm width X 50 mm depth X 1.6 mm thickness

50

-

-

... More
4.7.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
Talk -Back System

-

-

-

... More
Supply, installation, testing & commisioning of 19' Rack 400/500mm depth, 6U high rack assembly (wall/surface mountable type) made of MS equivalent to euro rack system, with side and rear panels made of 14 swg powder coated sheet steel front transparent persplexdoor and with rails, rollers & bearings. Side panels shall be ventilated type.The rack shall be powder coated of approved color.

1

-

-

... More
Supply, installation, testing & commisioning of PA Talk back control console of 24 zones complete with floor to floor announcing and talk back facilities with the following features and made functional: .- 19' Rack mount installation.- Attached Telephone handset.- 24V DC Power Supply.- Networkable upto 8 Controller.- Zone capacity: 5 handsets per zone

1

-

-

... More
Supply, installation, testing and commisioning of Public Address speaker with talk back facility with call switch, wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for surface mounting. 6W capacity.

63

-

-

... More
Supply, laying, testing and commissioning of 2 core 48/0.2 mm twin twisted copper pvc insulated un-armoured shielded speaker cable including end termination at field units etc. ( Fire resistant un armoured speaker cable)

4000

-

-

... More
Supply, installation and testing & commissioning of Medium duty, ISI marked, rigid PVC FRLS conduit including all accessories such as couplers, bends, junction boxes, reducers, adopters, elbows, tee, deep tees, spacers, saddles, screws, nuts, bolts, clamps, adhesive, pull boxes with hyleum sheet cover etc.. Rate should be inclusive of wall chasing, plastering, with mesh (wherever required), making good, excavation, refilling etc..20mm dia

3800

-

-

... More
Public Addressing System

-

-

-

... More
Blue ray DVD Player with option of MP3, MP4, AM, FM tuner with USB port, Aux port to play BGM (Back Ground Music).

1

-

-

... More
Racks with required tray / mounting accesories to mount controller, routers, amplifiers, cable managers etc. The Rack should have required Fan to exhaust the hot air generated in the rack. Rack mount power distribution unit, 1Ph, 230V, 16A, 50/60Hz, 2U standard with 6 X Indian Round Pin 5/15A, Inlet Plug type, 16A Indian Round Pin, 16A MCB - PDU Rating 3.6KVA/Side feed-1.5Mt/ Black .The input cables should be managed neatly inside the the rack as requried as complete..Amplifier rack assembly made of aluminium channel equivalent to euro rack system, with side and rear panels made of 14 swg powder coated sheet steel front transparent persplexdoor and with rails, rollers & bearings. Fans shall provided at the top for ventilation side panels will be ventilated type. The rack shall be powder coated of approved color and spare 'U' shall be covered with blank panels. 30 U Rack

1

-

-

... More
Supply and Interconnection between main console,routers & amplifiers and also between routers with suitable wires or cables including conduits/raceways, accessories as requried as complete etc..(Unshielded Twisted Pair Category 6 (CAT 6) 4 pair, copper-networking unarmoured LAN Cable )

40

-

-

... More
Supply, installation and testing & commissioning of Medium duty, ISI marked, rigid PVC FRLS conduit including all accessories such as couplers, bends, junction boxes, reducers, adopters, elbows, tee, deep tees, spacers, saddles, screws, nuts, bolts, clamps, adhesive, pull boxes with hyleum sheet cover etc.. Rate should be inclusive of wall chasing, plastering, with mesh (wherever required), making good, excavation, refilling etc..20mm dia

3700.51

-

-

... More
Supply, laying, testing and commissioning of 2 core 48/0.2 mm twin twisted copper pvc insulated un-armoured speaker cable including end termination at field units etc. ( Fire survival un armoured speaker cable)

3800

-

-

... More
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.

1

-

-

... More
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required.

307

-

-

... More
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

7

-

-

... More
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.

1

-

-

... More
Rack mountable solid state booster amplifier including control wires, jacks etc for the below mentioned RMS output - 480 watts.

7

-

-

... More
Sub head 6 - Extra Low Voltage System CCTV Surveillance System

-

-

-

... More
INDOOR BULLET -IP network true day/night IP66 / IK10 indoor Wall / Pole Mount Bullet PAL Colour Camera with min 1/3" Progressive scan CMOS - min 4 MP resolution image sensor, with min one H.264 stream for recording & one H264/MPEG 4/MJPEG stream for live viewing. It shall have the capability to deliver two independent video streams and shall be possible to set independent FPS (30 fps for M-JPEG and 30 fps for H.264)Compression selection (QCIF to 720P) for each stream with built in 2.8 - 12 mm lens, Motorized vari focal auto DC iris lens with built in WDR (120dB), HLC / automatic back light compensation circuitry for varying light levels and sensitivity of min 0.3 lux with IR illuminator OFF,0 Lux with IR illuminator ON (50mts IR distance) and sensitivity of min 0.5 lux at 40/50 IRE, SD card slot loaded with 64 GB card and with POE connectivity and also with external power supply with built in WEB Browser. The camera should be UL/BIS listed, ONVIF, with all mounting accessories as required.

4

-

-

... More
INDOOR DOME: IP network true day/night IP65 / IK10 indoor Dome PAL colour Camera with min 1/3" Progressive scan CMOS - min 4 MP resolution image sensor, with min one H.264 stream for recording one H264/MPEG 4/MJPEG stream for live viewing. It shall have the capability to deliver two independent video streams and shall be possible to set independent FPS (30 fps for M-JPEG and 30 fps for H.264)Compression selection (QCIF to D1 / 4 CIF/720P) for each stream with built in 2.8 / 3.6 / 6 / 8 mm lens as required, built in SD card option equiped with 32GB, indoor dome housing with built in WDR (120DB), HLC/ automatic back light compensation circuitry and sensitivity of min 0.3 lux with IR illuminator OFF,0 Lux with IR illuminator ON (20mts IR distance), PoE, also with the capability to add manufacturer power supply unit if required at site and with built in WEB Browser and required wall / ceiling mounting accessories as specified in the Tender Specifications. The cameras should be UL/BIS listed, ONVIF, with all mounting accessories as required

143

-

-

... More
INDOOR MULTI SENSOR (180degree): IP network indoor Multi Sensor Dome PAL color Camera with min 2 Nos. of 1/3" Progressive scan (for 180 degree coverage) CMOS/ CCD - with min. 4MP resolution image sensor, with min. one H.265 / H.264 stream for recordingone MPEG 4 / MJPEG stream for live viewing per sensor, with a single IP address for all channels. Camera angle adjustment (Pan+ or - 90degree, Tilt 25 degree-90 degree, Rotate + or - 90degree) for each lens. The camera shall be able to support seamless panoramic views and simultaneous Immersive Views that allow for the pan, tilt and zoom in, across the entire field of view. It shall have the capability to deliver two independent video streams per lens and shall be possible to set independent FPS (30 fps for M-JPEG and 30 fps for H.264)Compression selection (QCIF to D1 / 4 CIF) for each stream with built in 2.8 - 8 mm (or) close to it, Motorized vari focal, built in SD card (64GB), built in basic analytics, in indoor / outdoor dome housing (IP66,IK10) with built in WDR (120DB), HLC / automatic back light compensation circuitry and sensitivity (min. illumination - 0.3 lux at 30mts distance), PoE, also with the capability to add manufacturer power supply unit if required at site and with built in WEB Browser, integrated video analytics and required wall / ceiling / Pole mounting accessories as specified in the Tender Specifications. The cameras should be UL/BIS listed, conforming to ONVIF Profile with all mounting accessories as required

52

-

-

... More
INDOOR MULTI SENSOR (360 degree): IP network indoor Multi Sensor Dome PAL color Camera with min 4 Nos. of Min 1/3" Progressive scan (for 360 degree coverage) CMOS/ CCD - with min. 4MP resolution image sensor, with min. one H.265 / H.264 stream for recording one MPEG 4 / MJPEG stream for live viewing per sensor, with a single IP address and license for all channels. Camera angle adjustment (Pan + or - 90degree, Tilt 25degree-90degree, Rotate + or - 90degree) for each lens. The camera shall be able to support seamless panoramic views and simultaneous Immersive Views that allow for the pan, tilt and zoom in, across the entire field of view. It shall have the capability to deliver two independent video streams per lens and shall be possible to set independent FPS (30 fps for M-JPEG and 30 fps for H.264)Compression selection (QCIF to D1 / 4 CIF) for each stream with built in 2.8 - 8 mm (or) close to it, Motorized vari focal, built in SD card (64GB), built in basic analytics, in indoor / outdoor dome housing (IP66,IK10) with built in WDR (120DB), HLC/ automatic back light compensation circuitry and sensitivity (min. illumination - 0.3 lux at 30mts distance), PoE, also with the capability to add manufacturer power supply unit if required at site and with built in WEB Browser, integrated video analytics and required wall / ceiling / Pole mounting accessories as specified in the Tender Specifications. The cameras should be UL/BIS listed, conforming to ONVIF Profile,with all mounting accessories as required

1

-

-

... More
LIFT CAMERA: Supply, installation, testing, commisioning, handing over of the IR Vandal rated 2 MP IP Dome Camera for lifts applciations etc. with built in 2.8 mm (or) close to it lens, with built in SD card slot equiped with 16GB, in indoor dome housing with built in WDR (120DB), HLC/ automatic back light compensation circuitry and sensitivity of min 0.3 lux with IR illuminator OFF0 Lux with IR illuminator ON (20mts IR distance), PoE, also with the capability to add manufacturer power supply unit if required at site and with built in WEB Browser and required wall / ceiling mounting accessories as specified in the Tender Specifications. The cameras should be UL/BIS listed, ONVIF with all mounting accessories as required.

13

-

-

... More
Supply, laying termination of Flat type CAT 6/6A, 4 pair copper-networking LAN Cable, (for lifts), with PoE (complying IEEE802.3 AF and IEEE802.3 AT) Fluke testing with reports, labeling, as built drawings, with manufacturer warranty.

720

-

-

... More
Supply, Installation, Testing Commissioning of IP based Joy Stick

2

-

-

... More
128 Channel networked NVR System with Video Input 128 channel IP Video inputoutput, HDMI / VGA simultaneous video output. RAID 5 Implemented HDD Support Min. 8 SATA Port up to 96TB, Loaded with Surveillance HDD, (HDD supplied should support 30 days recording for H.264/H.265 at 20 fps @720P @RAID5@Good Bit rate) LAN Port, 2 USB Ports, Mobile Software, CMS Software: VMS, Etc. ONVIF Complied UL/BIS Listed

2

-

-

... More
LED TV with Min 40" diagonal screen size, Contrast ratio min. 6000:1, Native Resolution : 1920 X 1080; Aspect ration- 16:9, colour system - PAL/NTSC, Data signals - HDMI Detachable speakers, wall mount kit with PC Connectivity for Multi screen video display and with anti reflective screen coating as per Tender Specifications

2

-

-

... More
Monitoring PC Station Intel Min i7 processor or greater with min 16 GB RAM with DVD drive, V.G.A. Card, 2 GB Graphics card, dual monitor card, 512 GB SSD, 1TB HDD, Network Interface 10/100 MBNIC, Scroll Mouse original Softwares, Sounder card, Original OS (Windows ) software, Latest MS office software, Anti virus software ( vendor to indicate the list of other additional software considered in their offer), min 2 Serial Ports, 1 Parallel port, 4 USB Ports, 4 Expansion slots.

2

-

-

... More
OUTDOOR BULLET CAMERA - IP network true day/night IP66 / IK10 outdoor Wall / Pole Mount Bullet PAL Colour Camera with min 1/3" Progressive scan CMOS/ Progressive scan CCD /CMOS - min 4 MP resolution image sensor, with min one H.264 stream for recordingone MPEG 4/MJPEG stream for live viewing. It shall have the capability to deliver two independent video streams and shall be possible to set independent FPS (30 fps for M-JPEG and 30 fps for H.264)Compression selection (QCIF to 720P) for each stream with built in 2.8 - 12 mm lens, Motorized vari focal auto DC iris lens with built in WDR (120DB), HLC/automatic back light compensation circuitry for varying light levels and sensitivity of min 0.3 lux with IR illuminator OFF0 Lux with IR illuminator ON (50mts IR distance) and sensitivity of min 0.5 lux at 40/50 IRE, With SD card slot equiped with 64 GB card and with POE connectivity and also with external power supply with built in WEB Browser. The camera should be UL/BIS listed, ONVIF, with all mounting accessories as required

21

-

-

... More
Access Control System

-

-

-

... More
Providing Biometric / Card Reader with on board TCP/IP facility with PoE and display. The reader shall have the capacity to store 5000 cards, 1000 finger prints 40000 events as minimum. Should be UL/BIS certified (For attendance / Payroll function)

8

-

-

... More
Providing Biometric / Card Reader with on board TCP/IP facility with PoE .The reader shall have the capacity to store 5000 cards, 1000 fingerprints 40000 events as minimum. Should be UL / BIS certified.

4

-

-

... More
Cards which can read/ write CSN No and Sectors and with mounting accessories (2KB Memory) supporting with available Time attendance and Access control systems.

500

-

-

... More
Providing Request to Exit Switch

4

-

-

... More
Providing Single leaf door Electro Magnetic lock having Min holding force of 600LBS. with required mounting accessories, ZL brackets (where ever required) for all type of doors and with external (surface / recess mountable) door contacts. The lock should have dual colour LED

4

-

-

... More
Providing Magnetic Door Contacts for Access door

4

-

-

... More
Providing Resettable Press to open type Emergency door release box (Green) with a relay contact to indicate to the access controller when it is operated, the EDR should be monitored in by the ACS controller and should generate an alarm in the ACS S/W when EDR is activated.

4

-

-

... More
Access Control Time attendance software -Supply, Installation, Testing Commissioning of Network Access Management Software capable of addition, deletion, door access level addition, time zones..etc. with Time attendance system. The S/W should able to to control the doors (open and close ) from S/W. Software should support minimum 10000 employees with ADMIN Login and 2 User Login .

1

-

-

... More
Supply, laying, testing and commissioning of 6C x 1 Sqmm shielded FRLS copper cable between access reader, magnetic contact magnetic lock including termination.

20

-

-

... More
Supply, laying, testing and commissioning of 2Cx1 Sqmm Shielded FRLS copper cable between reader, EBG, Push button, power supply including termination.

20

-

-

... More
Supply and providing Push button Door Buzzer

4

-

-

... More
Active Components

-

-

-

... More
IP PBX --1000 port IP PBX system with ISDN PRI Capabilities from day one, (Expandable to minimum 1000 ports ) loaded for 550 Analog Extn,8 Digital .20 IP/SIP Extensions., 8 Normal Trunk, 1 No. ISDN PRI Trunk / SIP Trunks, 8 Port IVRS,350 Voice mail box, 2 Nos. attendant Console with minimum 48 DSS keys, 2No. Soft (PC) console license,2 Nos. IP/Digital Phones with minimum,24 DSS keys and display. Option to connect with HMS/PMS software for linking to the Hospital Servers as required The system should be compatible to communicate with other PBX through communication server/tie-lines with Built-In Auto Answer TDM/IP Coverage ISDN Compatibility Voice Mail Integration Paging Announcement Programmable Function Keys" Call Waiting-Including 15U Rack and Audio Cables for External Paging to connect with PA System.

1

-

-

... More
Supply and providing basic IP Telephone

10

-

-

... More
Supply Installation Testing and Commissioning of Basic Analog Phone with necessary mounting accessories and RJ11 Patch cord as required for complete installation as required by the engineer in charge

490

-

-

... More
Wireless access points with dual radio, 5GHz 802.11ax 4x4 MIMO and 2.4GHz 802.11ax 2x2 MIMO (IEEE 802.11ax) with a coverage radius of Min. 25 Mtrs. (SNMP manageable) which can work as standalone as well as controller based.

25

-

-

... More
Access Switch (Type A)- (Layer 2 or higher) Managable Stackable 24 Port PoE Switch with following components minimum 102 Gbps Back Plane 24 nos of 10/100/1000 RJ 45, 1 unpopulated 10G SFP Port minimum 2 unpopulated SFP Ports, One LX SFP module with Multi Mode Duplex Patch cords to connect to LC Couplers in the LIU provided ; out-of-band management port; option slot for 10 Gbps module ; 1 AC PSU, connector for external redundant PSU,with required stacking cable and Modules

14

-

-

... More
Access Switch (Type A)- (Layer 2 or higher) Managable Stackable 48 Port PoE Switch with following components minimum 174 Gbps Back Plane 48 nos of 10/100/1000 RJ 45, 1 unpopulated 10G SFP+ Port minimum 2 unpopulated SFP Ports, One LX SFP module with Multi Mode Duplex Patch cords to connect to LC Couplers in the LIU provided ; out-of-band management port; Addition option slot for 10 Gbps module ; 1 AC PSU, connector for external redundant PSU, with required stacking cable and Modules

26

-

-

... More
Core Switch (Layer 3) Managable with following Specification minimum 512 Gbps Back Plane for DATA , Throughput Aggregate Min. - 380 Mbps-for DATA , Should support at least 24 ports of 1000 Base-TX , 24 Nos 1000 Base- SFP ports, Plus 8 Nos 10G SFP+ ports, Redundant Power Supply Fan, and other required accessories and Management Module. POPULATED WITH 18 nos of populated SFP, 1000Base LX, LC connector with Multi Mode Duplex Patch cords to connect to LC Couplers in the LIU provided

2

-

-

... More
10G SFP+module with MM duplex Patch cord (LC LC)

10

-

-

... More
Water leak detector system 1 Nos Leak sensor and Water leak sensing cable with all accessories (end connectors, hold down clips etc.) of 16 Mtr length

2

-

-

... More
MS stand / pedestal for Network Racks (600 x 650) :- Heavy duty MS powder coated stand to support and elivate the racks (Max. Load 1200 Kg.) to a minimum height of 150mm from floor level with suitable platform for setting the rack above floor level.

13

-

-

... More
9U Wall mounted Rack (600W X 500D) mm wall mount closed rack with front glass door, vertical wire management systems, fan tray on top, 1*Horizontal Cable Manager1 nos power strip with standard accessories, all necessary hardware to mount the passiveactive equipment

1

-

-

... More
42U Network Rack (600W X 650D) mm floor mount closed rack with front glass door, vertical wire management systems, fan tray on top, perforated rear doors, side doors, casters, 2*Vertical Cable Manager, 7*Horizontal Cable Manager, openable entry at the bottom for the cable2 nos vertical power strip with 12 X Indian Round Pin 5/15A, with standard accessories, all necessary hardware to mount the passive active equipment .

13

-

-

... More
42U Server Rack Frame/800X1000/Steel/NRS/Casters Type 3, Levellers, 19" Adopter kit / Loops, FrontBack Perforated Door/800/42U/Dual/NRS, Side Panels/1000/42U/Vented/NRS, Swing Handle /Mechanical Lock / Three Point / Common Key/Die Cast Metal, ITE / Server Rack Air Circulation module/Tower Mount/360CFM, 2*Vertical Cable Manager,1Ph, 230V, 32A, Zero U standard Vertical rack mount power distribution unit with 12 X Indian Round Pin 5/15A, 2 Nos. (Inlet Plug Not Instilled, Recommended IEC30932A 2P +E), 16A MCB X 2 Circuits- PDU Rating 7.3KVA, Horizontal Cable Manager- 7 Nos

3

-

-

... More
Lubricated HDPE Pipe(Indoor) for OF Cable (100mm ID) Flexible as per TEC specification G/CDS-08/02 November 2004/IS 4984-1995

150

-

-

... More
24Port LIU , 1U, LC MM OM3/4, Fully Loaded

6

-

-

... More
Supply and Installation of 2 layer 600 - 600 Pair(Total 1200 Pair) MDF Box with Krone with necessary patch cables to connect with patch panel including necessary connections with all accessories required for complete installation as directed by the Engineer in charge

1

-

-

... More
Supplying and laying of following pair armored telephone cable through wall /tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.50 Pair Telephone Cable

240

-

-

... More
Supplying and laying of following pair armored telephone cable through wall /tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.100 Pair Telephone Cable

540

-

-

... More
Supply and Installation of 100 Pair MDF Box with Crone with necessary patch cables to connect with patch panel

6

-

-

... More
RG11 Coaxial Cable - Supplying and drawing of RoHS 2011/65/EU Compliant RG11 Co-axial cable less than 10 dB loss at 3000 MHz through wall/tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation

300

-

-

... More
Supply and installation of RoHS 2011/65/EU Compliant RG6 Co-axial cable with Foam Insulated Dielectric copper / copper clad steel inner conductor Aluminum braid shield + foil shield with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation

1390

-

-

... More
Outlet RG6 - Supply, fixing and commissioning of RG6 OutletRg6 Satellite cable Socket with face plate, white, jack, suitable PVC / GI Modular Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by the Engineer in charge

31

-

-

... More
Supply and Installation of 50 Pair MDF Box with Crone with necessary patch cables to connect with patch panel.

3

-

-

... More
Supply and Installation of 20 Pair MDF Box with Crone and necessary Patch cables to connect with patch panel

2

-

-

... More
12Port LIU , 1U, LC MM OM4, Fully Loaded

17

-

-

... More
Multi mode OFC Patch Chord (LC-LC) 3mtr

29

-

-

... More
Supplying and drawing of 12C LSHZ OFC Multi mode indoor / outdoor cable in the existing trays / trenches / concealed / Surface conduit etc. complete as required and directed.

1900

-

-

... More
Supplying and drawing of 6C LSHZ OFC Multi mode indoor / outdoor cable in the existing trays / trenches / concealed / Surface conduit etc. complete as required and directed.

1900

-

-

... More
Supply and fixing 1 Mtr long patch chord for Cat 6A Cable

1030

-

-

... More
Supply and fixing 2 Mtr long patch chord for Cat 6A Cable

800

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

3150

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

2400

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

350

-

-

... More
Supply, installation of RJ-45 jacks/ CAT 6A supported field termination plug ceiling connector assemblies) with boot separator.

266

-

-

... More
Supply, installation, testing and commissioning of Cat 6 A Patch Panel 24 Port (fully loaded) with rear cable management including crimping / Splicing patching of cable.

64

-

-

... More
Supply and fixing of Cat 6A single I/O telephone / data outlet with faceplate and back box.

763

-

-

... More
Supply, laying termination of CAT 6A 4 pair 23AWG / copper-networking LAN Cable with PoE (complying IEEE802.3 AF and IEEE802.3 AT) Fluke testing with reports, labeling, as built drawings, with 25 years manufacturer warranty.

67500

-

-

... More
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT6 Information Outlets (Key stone) with Shuttered Face plate, Single port, white, jack, suitable PVC / GI Modular Box etc. including necessary connections with Fluke test including necessary connections with all accessories required for complete installation as directed by the Engineer in charge accessories required for complete installation as directed by the Engineer in Charge

542

-

-

... More
Supply Installation of CAT6 Cable - Supplying and laying of Category 6 LSZH cable including fluke testing including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

29800

-

-

... More
Supply, Installation, Testing and installation of Cat - 6, 24 port fully loaded patch panel with necessary cable manager for routing the cable inside rack with all accessories required for complete installation as required as directed by the engineer in charge.

28

-

-

... More
Supply and fixing 2 Mtr long patch chord for Cat 6 Cable

10

-

-

... More
Raceway

-

-

-

... More
Supply and Installation of MS POWER COATED (GREY COLOUR)Raceways of 1.6 mm thickness with cover in ceiling and shafts, floor etc with complete MS supports fabricated per site requirements. It should also include the cost of bend tees etc as required 150X60X1.6mm thick

95

-

-

... More
Supply and Installation of MS POWER COATED (GREY COLOUR)Raceways of 1.6 mm thickness with cover in ceiling and shafts, floor etc with complete MS supports fabricated per site requirements. It should also include the cost of bend tees etc as required 200X60X1.6mm thick

410

-

-

... More
Supply and Installation of MS POWER COATED (GREY COLOUR)Raceways of 1.6 mm thickness with cover in ceiling and shafts, floor etc with complete MS supports fabricated per site requirements. It should also include the cost of bend tees etc as required 300X60X1.6mm thick

695

-

-

... More
Supply and Installation of MS POWER COATED (GREY COLOUR)Raceways of 1.6 mm thickness with cover in ceiling and shafts, floor etc with complete MS supports fabricated per site requirements. It should also include the cost of bend tees etc as required 400X60X1.6mm thick

45

-

-

... More
Supply and Installation of MS POWER COATED (GREY COLOUR)Raceways of 1.6 mm thickness with cover in ceiling and shafts, floor etc with complete MS supports fabricated per site requirements. It should also include the cost of bend tees etc as required. 100X60X1.6mm thick

450

-

-

... More
Sub head 7 - Vertical Transportation Passenger cum Bed Lifts

-

-

-

... More
26 Passenger cum Bed Lift-Design, fabrication, supply. installation, testing and commissioning of 26 Passenger cum Bed Lift – Gear less with Machine Room, Capacity / Weight 26 Pass (1768 Kg), Speed 1.5 MPS, electric traction type, Stainless steel (Including freight & landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with prerecorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. PMSM traction motor ( having efficiency equivalent to IE3 or better as in IS 12615) of machine room elevator shall be of gearless type and placed inside the machine room complete as per technical specifications. Having automatic centre/side opening stainless steel doors,Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details- 09 stops, 09 openings and entrance & exit at same side and suitable for travel height of 38 meter approximate. (Shaft Size 2500mm (width) x 3300mm (depth)) with door opening of 1200 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/Code and complete in all respects as per technical specifications. Test reports from NABL accredited testing labs for all constituent compounds shall be produced.

2

-

-

... More
26 Passenger cum Bed Lift-Design, fabrication, supply. installation, testing and commissioning of 26 Passenger cum Bed Lift – Gear less with Machine Room, Capacity / Weight 26 Pass (1768 Kg), Speed 1.5 MPS, electric traction type, Stainless steel (Including freight & landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with prerecorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. PMSM traction motor ( having efficiency equivalent to IE3 or better as in IS 12615) of machine room elevator shall be of gearless type and placed inside the machine room complete as per technical specifications. Having automatic centre/side opening stainless steel doors,Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details- 08 stops, 08 openings and entrance & exit at same side and suitable for travel height of 34 meter approximate. (Shaft Size 2500mm (width) x 3300mm (depth) with door opening of 1200 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components,fabrication and procedures shall confirm to relevant IS standards/Code and complete in all respects as per technical specifications. Test reports from from NABL accredited testing labs for all constituent components shall be produced.

5

-

-

... More
15 Passenger cum Bed Lift-Design, fabrication, supply. installation, testing and commissioning of 13 Passenger cum Bed Lift – Gearless with Machine Room, Capacity / Weight 15 Pass ( 1020 Kg), Speed 1.5 MPS, electric traction type, Stainless steel (Including freight & landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor,LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with prerecorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. PMSM traction motor ( having efficiency equivalent to IE3 or better as in IS 12615) of machine room elevator shall be of gear less type and placed inside the machine room complete as per technical specifications. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details- 05 stops, 05 openings and entrance & exit at same side and suitable for travel height of 21.0 meter approximate. (Shaft Size 2150mm (width) x 3250mm (depth)) with door opening of 900 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/Code and complete in all respects as per technical specifications. Test reports from NABL accredited testing labs for all constituent components shall be produced.

1

-

-

... More
Goods Cum Bed Lift

-

-

-

... More
2T Goods cum Bed Lift-Design, fabrication, supply. installation, testing and commissioning of electric traction type, with machine room type , Stainless steel, 2T capacity goods cum bed Hospital elevator (Including freight & landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1 Mtr/sec, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. PMSM traction motor (having efficiency equivalent to IE3 or better as in IS 12615) of machine room elevator shall be of gearless type and placed inside the machine room complete as per technical specifications. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details- 09 stops, 09 openings and entrance & exit at same side and suitable for travel height of 38 meter approximate. (Shaft Size 2500mm (width) x 3300mm (depth)) with door opening of 1500 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/Code and complete in all respects as per technical specifications. Test reports from NABL accredited testing labs for all constituent components shall be produced.

2

-

-

... More
2T Goods cum Bed Lift-Design, fabrication, supply. installation, testing and commissioning of electric traction type, with machine room type , Stainless steel, 2T capacity goods cum bed Hospital elevator (Including freight & landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V±10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1 Mtr/sec,electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons,overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser’s EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor (having efficiency equivalent to IE3 or better as in IS 12615) of machine room elevator shall be of gear less type and placed inside the machine room complete as per technical specifications. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details-08 stops, 08 openings and entrance & exit at same side and suitable for travel height of 34 meter approximate. (Shaft Size 2500mm (width) x 3300mm (depth)) with door opening of 1500 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/Code and complete in all respects as per technical specifications. Test reports from NABL accredited testing labs for all constituent components shall be produced.

3

-

-

... More
Sub head 8 - Medical Gas Pipeline System

-

-

-

... More
SITC of Oxygen Manifold - 2 banks x 12 cylinders

1

-

-

... More
SITC of Fully Automatic Oxygen Control Panel with minimum flow rate of 2000 LPM

1

-

-

... More
SITC of Emergency Oxygen Manifold - 2 banks x 6 cylinders

1

-

-

... More
SITC of Oxygen Flowmeters with humidifier bottle

344

-

-

... More
SITC of Nitrous Oxide Manifold - 2 banks x 2 cylinders

1

-

-

... More
SITC of Fully automatic Gas Control Panel for Nitrous Oxide with a minimum flow rate of 500 LPM

1

-

-

... More
SITC of Emergency Nitrous Oxide Manifold - 1 bank x 2cylinders

1

-

-

... More
SITC of Carbon Dioxide Manifold - 2 banks x 2 cylinders

1

-

-

... More
SITC of Fully automatic Gas Control Panel for Carbon Di Oxide with minimum flow rate of 500 LPM

1

-

-

... More
SITC of Emergency Carbon Dioxide Manifold - 1 bank x 2cylinders

1

-

-

... More
SITC of Triplex Compressed air plant system each compressor having minimum free air delivery of 2000 LPM with complete accessories as mentioned in technical specifications.(Imported)

1

-

-

... More
SITC of Duplex vacuum plant system each pump having minimum free air aspirated of 3000 LPM at 450 mmHg with complete accessories as mentioned in technical specifications. (Imported)

1

-

-

... More
SITC of Ward Vacuum Units

427

-

-

... More
SITC of Theater Vacuum Units

7

-

-

... More
SITC of ICU Terminal Units - Imported - O2

322

-

-

... More
SITC of ICU Terminal Units - Imported - Air

161

-

-

... More
SITC of ICU Terminal Units - Imported - VAC

322

-

-

... More
SITC of Ward Terminal Units - Indigenous - O2

266

-

-

... More
SITC of Ward Terminal Units - Indigenous - N2O

8

-

-

... More
SITC of Ward Terminal Units - Indigenous - Air

8

-

-

... More
SITC of Ward Terminal Units - Indigenous - Vac

266

-

-

... More
SITC of Matching Probe - O2

588

-

-

... More
SITC of Matching Probe - N2O

8

-

-

... More
SITC of Matching Probe - Air

169

-

-

... More
SITC of Matching Probe - VAC

588

-

-

... More
SITC of Master Plant Alarm Panel (post source), BMS compatible

1

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 6 Services

7

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 4 Services

23

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 2 Services

17

-

-

... More
SITC of Copper pipe - per mtr. - 12mm

3300

-

-

... More
SITC of Copper pipe - per mtr. - 15mm

3215

-

-

... More
SITC of Copper pipe - per mtr. - 22mm

4914

-

-

... More
SITC of Copper pipe - per mtr. - 28mm

1683

-

-

... More
SITC of Copper pipe - per mtr. - 35mm

641

-

-

... More
SITC of Copper pipe - per mtr. - 42mm

162

-

-

... More
SITC of Copper pipe - per mtr. - 54mm

144

-

-

... More
SITC of Copper pipe - per mtr. - 76mm

73

-

-

... More
SITC of Ball Valves - 15mm

9

-

-

... More
SITC of Ball Valves - 22mm

11

-

-

... More
SITC of Ball Valves - 28mm

6

-

-

... More
SITC of Ball Valves - 35mm

13

-

-

... More
SITC of Ball Valves - 42mm

5

-

-

... More
SITC of Ball Valves - 54mm

2

-

-

... More
SITC of Ball Valves - 76mm

1

-

-

... More
SITC of Bed Head Units - 1000 mm for Wards

26

-

-

... More
SITC of Bed Head Units - 1500 mm for ICU Category.

132

-

-

... More
SITC of Bed Head Panel - Running Meter

500

-

-

... More
SITC of Rigid Pendent

35

-

-

... More
Sub head 9 - Pneumatic Tube System

-

-

-

... More
Supply, Installation, testing and commissioning of PTS control units and sub components, control Softwares and Licenses for 3 zone system and RFID as per technical specifications. - Imported

1

-

-

... More
Supply, Installation, testing and commissioning of PTS control Computer and sub components for 3 zone system as per technical specifications.

1

-

-

... More
Supply, Installation, testing and commissioning of Grey color PTS Distribution tube OD 110 mm as per technical specifications (also meeting DIN 6660 / 6661 / 8061 / 8062 - Imported )

1050

-

-

... More
Supply, Installation, testing and commissioning of PVC Grey colour 90 degree Bend OD 110 mm with 2.3 mm thickness, , as per technical specifications (also meeting DIN 6660 / 6661 / 8061 / 8062- Imported )

160

-

-

... More
Supply, Installation, testing and commissioning of PVC Transparent Straight tube OD 110 mm with 2.3 mm thickness, 5000mm length as per technical specifications (also meeting DIN 6660 / 6661 / 8061 / 8062 - Imported )

30

-

-

... More
Supply, Installation, testing and commissioning of PVC Transparent 90 degree Bend OD 110 mm with 2.3 mm thickness, as per technical specifications (also meeting DIN 6660 / 6661 / 8061 / 8062 - Imported )

25

-

-

... More
Supply, Installation, testing and commissioning of DC power supply units, Control Cable Data-Com-Power Composite, Cable tie and sub components for system power distribution - Imported.

1

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled Intermediate / Pass through stations 110 mm with optical sensors for carrier tracking as per technical specifications - Imported

28

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled End stations 110 mm with RFID Transponder readers and optical sensors as per technical specifications. - Imported

1

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled End stations 110 mm with optical sensors as per technical specifications. - Imported

6

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled Multi Sending Lab stations 110 mm with RFID Transponder readers and optical sensors as per technical specifications. - Imported

1

-

-

... More
Supply, Installation, testing and commissioning of Fully automatic, microprocessor controlled LAB Receiving stations 110 mm with optical sensors, Carier receiving rail and Rail Extension, as per technical specifications. - Imported

2

-

-

... More
Supply, Installation, testing and commissioning of PTS 110 mm Swivel Caps Carriers with 2 RFID tags as per technical specifications. - Imported

108

-

-

... More
Supply, Installation, testing and commissioning PTS 3 way/4 way Diverters 110 mm as per technical specifications.

8

-

-

... More
Supply, Installation, testing and commissioning PTS transfer diverters 3 way/4 way Diverters 110 mm as per technical specifications.

6

-

-

... More
Supply, Installation, testing and commissioning of PTS 3-Phase Blower unit including Starter unit, Air Reversing unit and sub components for 110 mm each line as per technical specifications. - Imported.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.