INKEL Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 36,065Document Cost
₹ 2,950Tender Fee
Refer Documents
Summary
Additional Works For Opd Transformation In General Hospital, Kottayam Under Aardram Mission - Package Ii (sh Civil, Plumbing And Electrical Works)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_INKEL_413629_1Bid Award Id
ViewTender No
NIT/INKEL/ARDM/2020-21/220 dated 09/02/2021Tender Authority
INKEL Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
10
-
-
Sub Head: Reinforced Cement Concrete
-
-
-
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design).All work upto plinth level
5
-
-
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design.All work above plinth level upto floor V level
1
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete at all levels Thermo - Mechanically Treated bars of grade Fe-500D or more
559
-
-
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
35
-
-
Sub Head: Block Work
-
-
-
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
3
-
-
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
4
-
-
Sub Head: Joinery Work
-
-
-
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
304
-
-
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
606
-
-
21.2.2 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides
30
-
-
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
15
-
-
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
6
-
-
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness
4
-
-
21.11.2 : Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm
15
-
-
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
4
-
-
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm
6
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm
2
-
-
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm
8
-
-
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm
2
-
-
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium
15
-
-
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
200
-
-
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
290
-
-
10.2 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1250
-
-
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5 mm depth and 5 mm width
79
-
-
Frosted film - Supply and installation of 3M make frosted film pattern throughout all the internal glass panels wherever required of approx. 1.5 m height as per the approved pattern.
20
-
-
9.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.
4
-
-
Sub Head: Flooring
-
-
-
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(Note- Basic price of the tile-Rs 380/sqm any savings/reduction in basic price shall be accounted in the bill on pro rata basis.)
110
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.(Note- Basic price of the tile-Rs 430/sqm any savings/reduction in basic price shall be accounted in the bill on pro rata basis)
85
-
-
Providing and laying anti-skid Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.(Note- Basic price of the tile-Rs 380/sqm any savings/reduction in basic price shall be accounted in the bill on pro rata basis)
20
-
-
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks
in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,
thickness & size/ shape, made by table vibratory method using PU mould, laid in
required colour & pattern over 50mm thick compacted bed of sand, compacting and
proper embedding/laying of inter locking paver blocks into the sand bedding layer
through vibratory compaction by using plate vibrator, filling the joints with sand and
cutting of paver blocks as per required size and pattern, finishing and sweeping
extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
64
-
-
Hacking of floor and wall for tile work including cleaning for surface etc. complete as per<br>direction of the Engineer-in-Charge.
113
-
-
Sub Head: Finishes
-
-
-
13.4.2 : 12 mm cement plaster of mix:1:6 ( 1 cement : 6 coarse sand)
123
-
-
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
1304
-
-
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
107
-
-
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting to old wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture
223
-
-
14.53.1 : Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
1304
-
-
14.54.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work
223
-
-
Providing and fixing 160 dia PVC rain water gutter (pressure class 4Kg/sq.cm )with necessary iron brackets bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.
25
-
-
Providing and fixing ridges and hips in roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. : Using colour coated Aluminium sheets of guage 18.
15
-
-
Supply and Installation of color coated 0.5 TCT galvalume profile sheet including vertical/curved surface of overall width 1072mm(nominal 1015 mm effective cover width)and nominal 28mm deep ribs with subtle square fluting in the five pans at nominal 203 mm cente-to-centre.The end rib shall be designed for anticapillary action,to avoid any seepage of water through the lateral overlap, filled with white lead continuous spacer tape 6.4mm thick x 6 mm wide at all joints and junctions along its length.The feed material shall be of .45 mm BMT(.50 mm TCT excluding paint thickness)COLORBOND steel-Hi tensile with min 550 MPa yield strength,metallic hot dipped coated with Aluminium Zinc alloy (55% Aluminium 43.5% Zinc,1.5% Silicon)
90
-
-
Sub Head:Repairing Work
-
-
-
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
4
-
-
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
65
-
-
14.5.1 : Renewing glass panes, with putty and nails wherever necessary including racking out the old putty :Float glass panes of thickness 4 mm
3
-
-
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
25
-
-
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
3
-
-
14.17 : Raking out joints in lime or cement mortar and preparing the surface for re- pointing or re plastering, including disposal of rubbish to the dumping ground within 50 metres lead.
123
-
-
14.46 : Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
1304
-
-
PLUMBING
-
-
-
Supplying, installing, testing & commissioning at site in position white / colour vitreous china wash basin(550x400x195mm) with C.I./MS brackets painted white, C.P brass waste coupling of standard pattern,32mm dia C.P, basin Piller tap for wash basin (elbow operation) with aerator, including cutting & makinggood the walls wherever required complete.Flat back Pedestal wash basin Piller tap for wash basin (elbow operation) with aerator Model - JAQUAR CNS-WHT-801, FLR-5031N, ALD 709
4
-
-
Providing and fixing White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF Dual Cistern, overall size 765 x 370 x 650mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion/ rawl sleeves, gasket etc. complete, and fixing to wall, as per manufacturer's instruction and to the approval of Engineer-in-charge. Model Jaquar-FLS WHT- 5351,FLS -WHT-5201 or equivalent
1
-
-
Supplying, installing, testing & commissioning at site in position 15mm dia C.P Long Body brass aerator bib cocks with wall flange including cutting and making good the walls wherever required. Model - FLR-5047N- 1250 or Equivalent
1
-
-
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.Model -JAQUAR - ALD-CHR-585 or Equivalent Hand Shower (Health Faucet)(ABS Body) With 1 mtr long PVC Tube & Wall Hook or Equivalent.
1
-
-
Supplying, installing, testing & commissioning at site in position Heavy Duty Flexible Braided
Connectors, 15mm. nominal bore, 450mm. Long with higher thermal stability for cold and hot water, for Wash Basin & Kitchen Sink Mixer and Geyser points, of approved quality.
4
-
-
Supplying, installing, testing & commissioning at site in position 15 mm dia angle valve with CP wall
flange etc complete Model - JAQUAR FLR 5053 N or Equivalent
4
-
-
C. P. Robe Hook, 60mm. Dia. x 45mm. High. Model - JAQUAR ACN-1191N or Equivalent
1
-
-
Providing,fixing testing and commissioning 11⁄4"x 32x300 CP Brass Tube Trap (P Trap) for wash basin.Adjusting pipe 120mm, drain elbow 220mm. Model - Cat No: Viega 704872 or equivalent.
4
-
-
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree
bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm),Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site
(For Soil & Waste pipes -Internal).75mm OD
40
-
-
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B(IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm),Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site(For Soil & Waste pipes -Internal).110mm OD
15
-
-
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe of 6Kg/sq.cm (IS:4985)
including injection moulded fittings with bosses where required eg 90 Degree bend, 45 Degree bends, 'Y',couplings, adapters & clamping with Universal clamps 1mtr spacing, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).50 mm (IS 4985,6kg/cm2)
8
-
-
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type A
(IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree
bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm),Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site
For Vent pipes -Internal).110mm OD
20
-
-
uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost of cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken)
2
-
-
C.P. cast brass or stainless steel Square Flat cut lock anti cockroach grating cover - Providing and Fixing Heavy Duty Stainless Steel Square Flat cut lock anti Cockroach Trap Stainless Steel A ISI 304 with 153x153mm. Grating, for 110mm. Floor traps.
2
-
-
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes &fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft ;20 mm nominal outer dia. Pipes.
50
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain &brass threaded fittings, i/c fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - Ceiling and Shaft 20 mm nominal outer dia. Pipes.
5
-
-
Brass ball valve 20mm dia - Providing, Fixing at site in position full way lever operated forged Brass ball valve (screwed end)of brass body with forged brass hard chrome plate (PN 25) of approved make with necessary MTA fittings in position as per drawing - 3⁄4” (20mm) dia
4
-
-
19.7.1.2 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885
1
-
-
19.8.1.2 : Extra for depth for manholesSize 90x80 cmWith Sewer bricks conforming to IS : 4885
1
-
-
Supplying, Installing & Testing at site in position best quality PVC gully trap of size 160 X110mm outlet embedded in plain cement concrete 1:4:8 (20mm metal), all the above encased in a chamber of 300 X 300mm built with 115mm thick brick masonry using first class country bricks in CM 1:3 over a bed of CC 1:4:8 using 40mm size metal 100mm thick ,plastering with CM1:3,13mm thick inside, outside, exposed top surfaces and internal and top exposed surface finished smooth with a floating coat of neat cement,providing and fixing Ductile Iron(Hinged type) frame and cover of size 300 X 300mm weighing not less than 8 kgs load tested as per IS:1726 fixing the frame in PCC 1:2:4 using 20mm stone metal including painting the frame and cover with 2 coats of anticorrosive black bitumastic painting etc. complete all as specified and directed.
1
-
-
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying, Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete.110mm OD
10
-
-
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation to the specified hydrostatic test pressure including Supplying, Supplying, Installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete.75mm OD
5
-
-
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia
15
-
-
ELECTRICAL
-
-
-
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
20
-
-
1.54.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
5
-
-
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
150
-
-
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
250
-
-
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
40
-
-
1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
70
-
-
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
250
-
-
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
250
-
-
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
3
-
-
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
4
-
-
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
3
-
-
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
3
-
-
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
9
-
-
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
5
-
-
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
6
-
-
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
3
-
-
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
3
-
-
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
3
-
-
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).
8
-
-
1.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
8
-
-
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
30
-
-
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
3
-
-
1.48 : Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
35
-
-
DISTRIBUTION BOARD
-
-
-
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
1
-
-
Supplying and fixing following rating 25A, double pole, (single phase and neutral), 240 V, RCBO,having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
8
-
-
LIGHT FIXTURES-ELECTRICAL
-
-
-
SITC of 20W (+/-10% tolerance) 4ft LED luminaire having /= 1500 lm system output (Luminaire lumen output). ANSI rated LEDs from reputed makes should be provided. Luminaire efficacy should be greater than or equal to 80 lumens/watt and with minimum 2 KV surge protection. Catalogue Number :: Wipro LL20-221-XXX-65-NE TrimLED Neo / Crompton:LDSL-20-CDL / Equivalent Philips MakeNote: Ligh.t fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.
12
-
-
SITC of 5W (+/-10% tolerance) 1ft LED luminaire having /= 400 lm system output (Luminaire lumen output). ANSI rated LEDs from reputed makes should be provided. Luminaire efficacy should be greater than or equal to 85 lumens/watt and with minimum 2 KV surge protection. Catalogue Number : Wipro / Crompton / Philips Make Note: Light fixtures complete with all necessary accessories including suspenders, PVC Flexible pipes, adopters, connectors etc as required (Sample shall be approved by the engineer in charge). The installation shall be complete in all respects.
1
-
-
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ;canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C
9
-
-
Supply of 300 mm sweep Exhaust fan with Metal blades of approved colour, quality and complete the work in good condition as directed by the engineer in charge. Make: (Alomonard, Bajaj, Havells, Crompton)
3
-
-
Supply of 400mm Sweep Wall Fan with necessary Bracket and Clamps;Make: (Havells, Crompton, Bajaj)
1
-
-
90.15.4.6 : Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
2
-
-
SITC of 20W (+/-10% tolerance) LED Gate/Post top light fitting with IP65 Protection, 5kv surge protection. ;Wipro (LP07-251-XXX-57-CL) / Equivalent Crompton and Philips Make
33
-
-
CABLING-ELECTRICAL
-
-
-
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor, AXFY power cable confirming to IS 7098 (part 1) ammended upto date. 3cx04sq.mm CU Cable
210
-
-
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor, AXFY power cable confirming to IS 7098 (part 1) ammended upto date. 3cx2.5sq.mm CU Cable
280
-
-
Supplying and making end termination with brass compression gland and Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
3C X 04 sq. mm
4
-
-
7.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size direct in ground including excavation, sand cushioning, protective covering and
refilling the trench etc as required.Upto 35 sq. mm
20
-
-
7.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
440
-
-
7.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
30
-
-
90.12.10.3 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation
160
-
-
14.3 : Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres.
36
-
-
EARTHING-ELECTRICAL
-
-
-
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
75
-
-
90.3.17.2 : Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements