Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

INKEL Limited - INKEL Tender

Works
Building Construction
Eprocure
Opening Date2 Feb 2019
Closing Date25 Feb 2019
Tender Amount₹ 7,37,06,295 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Chilled Water Secondary Pumps Supply, installation, testing & commsssioning the chilled water secondary pumps as per specification including all accessories as specified and as required. Endsuction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, base plate couplings, anti vibration springs, guards etc. including insulation as per specifications: Including Factory made base frame & fixing foundation with necessary fittings as required. Capacity : 336 USgpm, 1440rpm Head : 80 feet/24.38metre Motor : 10 H.P (suggested) - IE 2, Efficiency 85%

4

-

-

... More
Variable Frequency Drive Supply, Installation, Testing & commissioning of complete VSPS Variable Frequency Drive, IP54 control panel consisting of IP 20 adjustable frequency drive (AFD) for each pump. One dedicated microprocessor based pump controller per zone housed within this enclosure panel with parallel pumping software duly downloaded and single/multiple differential pressure sensor/transmitters as per the site requirement. The entire system along with secondary pumps as described above must be sourced from single manufacturer only, to ensure unit responsibility. The VFD should be incorporated with RFI(radio frequency interference) filters which can control THDi [Total Harmonic Distortion Current] below 3% or as per IEEE 519. Auto bypass starters, compactable to the third party BMS to be included.

1

-

-

... More
Condenser Water Pumps Supply, Installation, testing & commsssioning the condenser water pumps as per specification including all accessories as specified and as required. Endsuction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, base plate couplings, anti vibration springs, guards etc. including insulation as per specifications: Including Factory made base frame & fixing foundation with necessary fittings as required. Capacity : 560 USgpm, 1440rpm Head : 70 feet/21.34metre Motor : 10 H.P (suggested) - IE 2, Efficiency 85%

4

-

-

... More
Cooling Towers Supply, Installation, testing & commsssioning the cooling towers as per specification including all accessories as specified and as required. COOLING TOWERS of actual capacity complete in all respects as per technical specifications and equipment schedule complete with FRP casing, FRP fan cylinder, PVC louvers, PVC drift eliminator polypropelene nozzles, drive assembly, HDG fan guard/bird screen, non-clogging nozzle type water distribution system. PVC fill, aluminium ladder with railings, make up, quick fill, drain over flow connections etc. as per specifications. Including R.C.C foundation along with PCC/RCC sub base, fixing with bolts and nuts and finishing the slabs or any opening etc. EWT = 97.5 degree F LWT = 90 degree F WET bulb = 82 degree F Flow rate = 560 USgpm 140 TR - CTI/JCI approved induced draft, cross or counter flow cooling tower with vertical air discharge. Motor suggested - 5 HP

3

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 32 TR, 12800 CFM, 25.6 sq.ft./ 4 row - (Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 24 TR, 9600 CFM, 19.2 sq.ft./ 4 row - (Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

2

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 20 TR, 8550 CFM, 17 sq.ft./ 6 row - (Double Skin Floor mounted Horizontal AHU with mixing box, 10 micron pre filters) ( Detailed Technical specification attached).

2

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 20 TR, 8000 CFM, 16 sq.ft./ 4 row - (Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

2

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 18 TR, 7200 CFM, 14.4 sq.ft./ 4 row - (Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

2

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 16 TR, 6400 CFM, 12.8 sqft./ 4 row - (Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 15 TR, 6030 CFM, 12 sq.ft./ 4 row -(Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 12 TR, 4800 CFM, 9.6 sq.ft./ 4 row - (Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 10 TR, 4000 CFM, 8 sq.ft./ 4 row -(Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

2

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 10 TR, 4000 CFM, 8 sq.ft./ 6 row - (Double Skin floor mounted Horizontal unit with mixing box, 2 X 3kW heater) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 8 TR, 3200 CFM, 6.4 sq.ft./ 4row - (Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 7 TR, 2800 CFM 5.6 sq.ft./ 4 row - (Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 5 TR 2000 CFM 3.7 sq.ft./ 4 row - (Double Skin floor mounted Horizontal unit with mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 25 TR, 10000 CFM, 20 sq.ft./ 4row - (Double Skin floor mounted Horizontal unit with fine filter and mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 16 TR, 6400 CFM, 12.8 sq.ft./ 4 row - (Double Skin floor mounted Horizontal unit with fine filter and mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 10 TR, 4000 CFM, 8 sq.ft./ 4 row - (Double Skin floor mounted Horizontal unit with fine filter and mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 5 TR, 2000 CFM, 4.8 sq.ft./ 4 row -(Double Skin floor mounted Horizontal unit with fine filter and mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 16 TR, 6400 CFM, 12.8 sq.ft./ 4 row - (Double Skin ceiling suspended AHU ) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 15 TR, 6000 CFM, 12 sq.ft./ 4 row -(Double Skin ceiling suspended AHU ) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 14 TR, 5600 CFM, 11.2 sq.ft./ 4 row - (Double Skin Ceiling suspended AHU) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 12 TR, 4800 CFM, 9.6 sq.ft./ 4 row - (Double Skin Ceiling suspended AHU) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 7 TR, 2800 CFM, 5.6 sq.ft./ 4 row -(Double Skin ceiling suspended AHU ) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 9 TR, 3600 CFM, 8 sq.ft./ 4row - (Double Skin ceiling suspended AHU with mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 4 TR 1600 CFM, 3.2 sq.ft./ 4 row - (Double Skin ceiling suspended AHU with mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 5 TR, 2000 CFM, 4.8 sq.ft./ 4 row - (Double Skin ceiling suspended AHU with fine filter and mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 4 TR 1600 CFM, 3.2 sq.ft./ 4 row - (Double Skin ceiling suspended AHU with fine filter and mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 3 TR 1200 CFM, 2.4 sq.ft./ 4 row - (Double Skin ceiling suspended AHU with fine filter and mixing box, 2 x 2KW heater) ( Detailed Technical specification attached).

1

-

-

... More
Air Handling Units Supply, Installation, testing & commssioning the Air Handling Units as per specification including all accessories as specified and as required. VFD driven AHU with plug fans and VFD starter panel with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included. Only HVAC application VFD's shall be used. All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU. : 3 TR 1200 CFM, 2.4 sq.ft./ 4 row - (Double Skin ceiling suspended AHU with fine filter and mixing box) ( Detailed Technical specification attached).

1

-

-

... More
Treated fresh air unit with enthalpy wheel, VFD, supply-exhaust fans, cooling coil: Supply at site, including, local transport, unload, store, handle, erect, balance and commissioning of the entire Heat Recovery AHU as per specifications including all accessories as specified and as required Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F, RH-58% Monsoon Ambient conditions: DBT – 85 deg F, WBT- 82 Deg F, RH-88% Return air condition: DBT- 75 Deg F, RH– 75% Return fan - 40 mm to 60 mm WG Supply air condition: DBT- 75 Deg.F., RH–50+/-5% Supply Fan Static - 60 to 70 mm WG Overall Efficiency 80- 85% TFA - 26 TR AHU, 9.4 sq.ft./8row coil with 4700 CFM Supply fan, 4300 CFM Return fan and heater coil of 2 x 3kW.

1

-

-

... More
Fan Coil Unit FCU's with valve station - Low/Medium/High static to be selected as per final ducting dwgs or as instructed by the engineer in charge Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch and INCLUDING 2 WAY TYPE PRESSURE INDEPENDENT VALVE (ON/OFF) - 0.75 TR Hideway FCU

28

-

-

... More
Fan Coil Unit FCU's with valve station - Low/Medium/High static to be selected as per final ducting dwgs or as instructed by the engineer in charge Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch and INCLUDING 2 WAY TYPE PRESSURE INDEPENDENT VALVE (ON/OFF) - 1.0 TR Hideway FCU

24

-

-

... More
Fan Coil Unit FCU's with valve station - Low/Medium/High static to be selected as per final ducting dwgs or as instructed by the engineer in charge Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch and INCLUDING 2 WAY TYPE PRESSURE INDEPENDENT VALVE (ON/OFF) - 1.5 TR Hideway FCU

9

-

-

... More
Fan Coil Unit FCU's with valve station - Low/Medium/High static to be selected as per final ducting dwgs or as instructed by the engineer in charge Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch and INCLUDING 2 WAY TYPE PRESSURE INDEPENDENT VALVE (ON/OFF) - 2 TR Hideway FCU

4

-

-

... More
Fan Coil Unit FCU's with valve station - Low/Medium/High static to be selected as per final ducting dwgs or as instructed by the engineer in charge Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch and INCLUDING 2 WAY TYPE PRESSURE INDEPENDENT VALVE (ON/OFF) - 2.5 TR Hideway FCU

1

-

-

... More
Fan Coil Unit FCU's with valve station - Low/Medium/High static to be selected as per final ducting dwgs or as instructed by the engineer in charge Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch and INCLUDING 2 WAY TYPE PRESSURE INDEPENDENT VALVE (ON/OFF) - 3 TR High static FCU

3

-

-

... More
Four Way Cassette Unit Supply, installing, testing and commissioning of following four way cassette unit as per specification including all accessories as specified and as required - 3 TR four way cassette unit

1

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 250 mm dia.

15

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 200 mm dia.

50

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 150 mm dia.

115

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 125 mm dia.

130

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 100 mm dia.

90

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 80 mm dia.

115

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 65 mm dia.

300

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 50 mm dia.

390

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 40 mm dia.

260

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 32 mm dia.

300

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 25 mm dia.

300

-

-

... More
CHILLED WATER PIPING & VALVES Supply, receive, store, handle, install, test and commissioning of the following pre insulated chilled water MS class (B) pipes, including high tech supports complete with all fittings such as bends, tees, elbows, reducers flanges, special fittings, suspension hangers, supports etc. as required for installation as per site conditions and as per specifications. Undergorund piping shall have bitumen coating. Piping insulation shall be expanded polyurethane foam with 36 kg/cu m minimum density, 90% minimum closed cell content, minimum compressive strength of 40 psi and thermal conductivity of 0.14 Btu-in/hr/ft2/°F. The insulation shall completely fill the annular space between the service pipe and jacket and shall be bonded to both, the service pipe & jacket. All the fittings & bends shall be finished with the same finish as specified for preinsulated pipe, supplied by the same company. All supports pipes to be welded with V-cut grooves as per specifications. MS Class B, IS 3589, IS 1239 piping. RCC opening as good as same. Wall opening as good as same. - 20 mm dia.

475

-

-

... More
Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection. - 250 mm dia.

50

-

-

... More
Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection. - 125 mm dia.

60

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 19 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. - 32 mm dia. PVC

150

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 19 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same. - 20 mm dia. PVC

500

-

-

... More
Butterfly Valves Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly Valves for AHU, Chiller Plant, Floor isolation: Supplying, fixing, testing and commissioning of following Butterfly valves (Manual) with CI body extended stem, SGI nylon coated/ductile iron disc, EPDM Seal & O-Ring PN 16 pressure rating for chilled water circulation as specified. All butterfly valves shall be provided with locking devices. Valve above 300 mm dia shall be gear driven. - 250 mm dia.

2

-

-

... More
Butterfly Valves Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly Valves for AHU, Chiller Plant, Floor isolation: Supplying, fixing, testing and commissioning of following Butterfly valves (Manual) with CI body extended stem, SGI nylon coated/ductile iron disc, EPDM Seal & O-Ring PN 16 pressure rating for chilled water circulation as specified. All butterfly valves shall be provided with locking devices. Valve above 300 mm dia shall be gear driven. - 200 mm dia.

2

-

-

... More
Butterfly Valves Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly Valves for AHU, Chiller Plant, Floor isolation: Supplying, fixing, testing and commissioning of following Butterfly valves (Manual) with CI body extended stem, SGI nylon coated/ductile iron disc, EPDM Seal & O-Ring PN 16 pressure rating for chilled water circulation as specified. All butterfly valves shall be provided with locking devices. Valve above 300 mm dia shall be gear driven. - 125 mm dia.

2

-

-

... More
Butterfly Valves Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly Valves for AHU, Chiller Plant, Floor isolation: Supplying, fixing, testing and commissioning of following Butterfly valves (Manual) with CI body extended stem, SGI nylon coated/ductile iron disc, EPDM Seal & O-Ring PN 16 pressure rating for chilled water circulation as specified. All butterfly valves shall be provided with locking devices. Valve above 300 mm dia shall be gear driven. - 100 mm dia.

26

-

-

... More
Butterfly Valves Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly Valves for AHU, Chiller Plant, Floor isolation: Supplying, fixing, testing and commissioning of following Butterfly valves (Manual) with CI body extended stem, SGI nylon coated/ductile iron disc, EPDM Seal & O-Ring PN 16 pressure rating for chilled water circulation as specified. All butterfly valves shall be provided with locking devices. Valve above 300 mm dia shall be gear driven. - 80 mm dia.

8

-

-

... More
Butterfly Valves Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly Valves for AHU, Chiller Plant, Floor isolation: Supplying, fixing, testing and commissioning of following Butterfly valves (Manual) with CI body extended stem, SGI nylon coated/ductile iron disc, EPDM Seal & O-Ring PN 16 pressure rating for chilled water circulation as specified. All butterfly valves shall be provided with locking devices. Valve above 300 mm dia shall be gear driven. - 65 mm dia.

16

-

-

... More
Butterfly Valves Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly Valves for AHU, Chiller Plant, Floor isolation: Supplying, fixing, testing and commissioning of following Butterfly valves (Manual) with CI body extended stem, SGI nylon coated/ductile iron disc, EPDM Seal & O-Ring PN 16 pressure rating for chilled water circulation as specified. All butterfly valves shall be provided with locking devices. Valve above 300 mm dia shall be gear driven. - 50 mm dia.

30

-

-

... More
Butterfly Valves Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. Butterfly Valves for AHU, Chiller Plant, Floor isolation: Supplying, fixing, testing and commissioning of following Butterfly valves (Manual) with CI body extended stem, SGI nylon coated/ductile iron disc, EPDM Seal & O-Ring PN 16 pressure rating for chilled water circulation as specified. All butterfly valves shall be provided with locking devices. Valve above 300 mm dia shall be gear driven. - 40 mm dia.

34

-

-

... More
Ball valves/Drain valves Supplying, fixing, testing and commissioning of following Ball valves/Drain valves for AHUs, plant room & chilled water piping adequately supported as per specifications. - 32 mm dia

14

-

-

... More
Ball valves/Drain valves Supplying, fixing, testing and commissioning of following Ball valves/Drain valves for AHUs, plant room & chilled water piping adequately supported as per specifications. - 25 mm dia

14

-

-

... More
Non- Return Valve Supply, installation, testing & commissioning of the following non return valves as per the specifications and as required. Non Return valves up to 65mm size shall be of gun metal with screwed female ends. Valves of 65mm and above shall be of CI with flanged ends. PN 16 pressure rating, EPDM seal. Non- Return Valve of size:- 125 mm dia

8

-

-

... More
Balancing Valve With Provision For Flow Measurement: Supply, installation, testing & commissioning of Balancing valve with built in measuring facility, C.I Body with EPDM seal, long pitch with protected out pipe insulation & PN 16 pressure rating for chilled water as specified. Balancing Valve with 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections; Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/-, necessary insulation as per specification Balancing valve with built in measuring facility 125 mm dia

3

-

-

... More
SUCTION GUIDE with strainer: Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required. Size: 125 mm dia.

8

-

-

... More
Supply, installation, testing & commissioning of the following motorized cut off valves as per the specifications and as required. Cl Body, Nylon coated DI disc, EPDM seal, minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required. Size: 125 mm dia.

3

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. - Y- Strainer of 65 mm dia

5

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. - Y- Strainer of 50 mm dia

12

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. - Y- Strainer of 40 mm dia

15

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. - Y- Strainer of 32 mm dia

5

-

-

... More
Y STRAINER FOR AHU's: Supplying, fixing, testing and commissioning of following Y- Strainer in the chilled water piping duly insulated to the same specifications as the connected piping and adequately supported as per specifications. - Y- Strainer of 20 mm dia

4

-

-

... More
Two Way Type Pressure Independent Balancing Cum Modulating Flow Control Valve: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification - 65mm dia.

5

-

-

... More
Two Way Type Pressure Independent Balancing Cum Modulating Flow Control Valve: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification - 50mm dia.

12

-

-

... More
Two Way Type Pressure Independent Balancing Cum Modulating Flow Control Valve: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification - 40mm dia.

15

-

-

... More
Two Way Type Pressure Independent Balancing Cum Modulating Flow Control Valve: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification - 32mm dia.

5

-

-

... More
Two Way Type Pressure Independent Balancing Cum Modulating Flow Control Valve: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification - 20mm dia.

4

-

-

... More
PRESSURE GAUGE - For chiller, pumps, AHU: Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection: Brass, NPS 12mm dia bottom-outlet type, Dial: Satin-faced, non-reflective aluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification.

104

-

-

... More
THERMOMETERS - For chiller, pumps, AHU: Supply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

104

-

-

... More
Supply, installation, testing & commissioning of differential pressure switch as per the specifications and as required.

3

-

-

... More
Supply and fix flexible connections with control rods for pumps and chiller. Size: 125 mm dia.

22

-

-

... More
Design, supply, installation, testing and commissioning of Pressurised chilled water expansion tank of 500L capacity with make up connection for closed loop system along with necessary pneumatic devices and accessories and MS 'C' section supports in order to keep chilled water under pressure.The tank shall be precharged steel tank with replacable heavy duty butyl rubber bladder. The tank shall have 50mm system connection and 20mm drain and charging valve connection to facilitate on-site charging of tank.The tank shall be fitted with lifting rings and floor mounting skirt for vertical installation.The tank shall be constructed according to section 8 of ASME boiler and pressure vessel code or equivalent and stamped 125psi working pressure.The contractor shall submit calculation regarding the above data. Pumps shall be of N+1 configuration. including with control wiring

1

-

-

... More
Supply, installation, testing & commissioning of a common air separator on the chilled water return line located at the pump suction and suitable for Secondary pump water flow; the separator shall be complete with high capacity air vent, flanges, service valve, non return valve, isolation butterfly valve for makeup water inlet. Capacity suitable for 1008 USGPM and 250mm NB CHW Header line

1

-

-

... More
AUTO AIR VENTS: Supply & install of airvents / purge valves including 15mm Ball Valves at the highest points in chilled water piping complete each floor with pipes nipple welded to pipe, hex nipple, socket, U-pipe connection at outlet of air vent etc. as required.

41

-

-

... More
CONDENSER WATER PIPING & VALVES Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same. - 250mm dia.

200

-

-

... More
CONDENSER WATER PIPING & VALVES Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same. - 150mm dia.

85

-

-

... More
Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supplying, fixing, testing and commissioning of following Butterfly valves (Manual) with CI body SGI nylon coated/ductile iron disc, EPDM Seal & O-Ring, PN 16 pressure rating for condenser water circulation as specified. All butterfly valves shall be provided with locking devices. Valve above 300 mm dia shall be gear driven. BUTTERFLY VALVE (MANUAL) 150 mm

20

-

-

... More
Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. Supplying, fixing, testing and commissioning of following non return valves, in the condenser water piping and adequately supported as per specifications. Non Return valves up to 65mm size shall be of gun metal with screwed female ends. Valves of 65mm and above shall be of CI with flanged ends. PN 16 pressure rating, EPDM seal. Non- Return Valve of 150 mm dia

4

-

-

... More
Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required Size: 150 mm dia

4

-

-

... More
Supply and fix flexible connections with control rods for pumps, cooling tower & condenser. Size: 150 mm NB

14

-

-

... More
Supply, installation, testing & commissioning of Balancing Valve, with built in measuring facility with C.I Body, 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections;Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/- Size: 150 mm NB

6

-

-

... More
Supply, installation, testing & commissioning of the following motorized cut off valves as per the specifications and as required. Cl Body, Nylon coated DI disc, EPDM seal, minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required. Size: 150 mm dia

6

-

-

... More
Supply, installation, testing and commissioning of 4" Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

14

-

-

... More
Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection: Brass, NPS 12mm dia bottom-outlet type, Dial: Satin-faced, non-reflective aluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification.

14

-

-

... More
Supply, installation, testing & commissioning of differential pressure switch as per the specifications and as required.

3

-

-

... More
DUCTING, GRILLS, DIFFUSER & INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. - Thickness 0.63mm GSS sheet

2735

-

-

... More
DUCTING, GRILLS, DIFFUSER & INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. - Thickness 0.80mm GSS sheet

1660

-

-

... More
DUCTING, GRILLS, DIFFUSER & INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. - Thickness 1 mm GSS sheet

245

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for major & Minor OT's, CT, Bunker - Thickness 0.80 mm Al. Sheet ducting

185

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for major & Minor OT's, CT, Bunker - Thickness 0.80 mm Al. Sheet ducting

130

-

-

... More
Supply installing, testing and commissioning of fine filters of efficiency 99.9% down to 5 microns in filter plenum in suitable frame work for MRI/CT: Fine filters - 8550 cfm

1

-

-

... More
Supply, install, testing and commissioning of strip heaters comprising thermostat, humidistat, safety thermostat, contactors. Minimum capacity of each strip heaters shall be 3 KW. Total heater capacity: 3kW

2

-

-

... More
Supplying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

7.5

-

-

... More
Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

13.5

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 - SD: 375×375

485

-

-

... More
Supply and fixing of Square Supply air diffusers of powder coated Aluminium with opposed blade dampers with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 - SD: 450×450

15

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 - RD: 375×375

490

-

-

... More
Supply and fixing of Square Return air diffusers of powder coated Aluminium with removable core as per drawings for the following neck sizes. The diffusers shall have extended flanges to match the grid tile of 600x600 - RD: 450x450

16

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc as per standards and specification. - Size: 300 mm dia

700

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc as per standards and specification. - Size: 350 mm dia

30

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes - 450X450X400H

485

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes - 600X600X450H

15

-

-

... More
SITC of Factory made fresh air dampers with louvers and control lever, filter etc as required. (as per drawing)

32

-

-

... More
Supply, Insulation, testing and commissioning of louvre type smooth supply air duct dampers made of extruded aluminium linkage, lever, brass bushings complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges, fixing arrangement etc, as per specifications. Al. volume control duct damper

28

-

-

... More
Supply and fix 1 1/2 hour fire rated fire dampers in air ducts (main line) with fusible link & microswitch to shut of corresponding AHU (including control cable).

15

-

-

... More
VAV (Variable Air Volume) unit: SITC of VAVs for supply air in rectangular ducts including thermostat and controls. Casing and damper blade made of galvinized sheet steel with proper seal and polyurethane plain bearings. Sensor tubes should be aluminium, maintenance free damper blade with minimum leakage rate. Actuator suitable for AC 24V 50 Hz and rated for dust pressure upto 50mm water gauge. VAV - 1500 cfm

2

-

-

... More
Thermal insulation: Supply & fixing of 8 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3

3000

-

-

... More
Acoustic insulation: Supply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140-180kg/m3

900

-

-

... More
Non ac area duct insulation: Supply & fixing of 19 mm thick Class O nitrile rubber insulation with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3

955

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 80 CFM

6

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 100 CFM

6

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 150 CFM

11

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 200 CFM

3

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 250CFM

5

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 300 CFM

2

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 350 CFM

2

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 450 CFM

1

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 500CFM

4

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 550 CFM

1

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 600CFM

1

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 650CFM

2

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 700 CFM

5

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 800 CFM

1

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 1000 CFM

3

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 1100 CFM

1

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 1250 CFM

1

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 1500 CFM

6

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 3500 CFM

1

-

-

... More
VENTILATION SYSTEM Axial Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/powder coated steel construction with required rating, single motor and flexible connection to connect with ducting/plenum.- 4000 CFM

2

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 - Thickness 0.63mm Sheet

600

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 - Thickness 0.80mm Sheet

25

-

-

... More
Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification Size: 100mm dia.

600

-

-

... More
Grilles And Diffusers Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers of design to be approved (material-Al): Return air grille/diffuser with vcd

10

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) Pump Panel (Total HP- 105 HP) with Energy meter in the Panel NOTE: Additional incoming metering panel for each chiller to be included in the chiller cost. All the panels shall be compactable for BMS

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 1 (Total HP- 14 HP) with above specifications & as per drawings - Lower Ground 2

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 2 (Total HP-11 HP) with above specifications & as per drawings - Lower Ground 1

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 3 (Total HP- 34.5 HP) with above specifications & as per drawings - Ground Floor

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 4 (Total HP- 22.5 HP) with above specifications & as per drawings -Ground Floor

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 5 (Total HP- 12 HP) with above specifications & as per drawings - Second Floor

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 6 (Total HP- 21.4 HP) with above specifications & as per drawings - Third Floor

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 7 (Total HP- 8 HP) with above specifications & as per drawings - Fourth Floor

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 8 (Total HP- 46 HP) with above specifications & as per drawings - Terrace Floor

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 9 (Total HP- 7 HP) with above specifications & as per drawings - Terrace Floor

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 10 (Total HP- 23 HP) with above specifications & as per drawings - Terrace Floor

1

-

-

... More
ELECTRICAL WORK Fabrication, supply, erection, testing and commissioning of dust and vermin proof, floor mounted, front operated MV panel board made out of 14 SWG thick CRCA sheet (7 tank treatment) fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components including fully automatic Star/delta/DOL starters for pumps, Variable Speed drives suitable for cubicle panel mounting inside the main panel for secondary pumps Control wiring, interlocks, push buttons, indication lamps etc. All the panels shall be compactable for BMS & CPRI Approved. All mandatory and statuatory sanction orders and approvals from the electrical inspectorate and KSEB shall be obtained by the contractor before energizing the system. (Rate Quoted as per the attached Electrical Scheme) AHU Panel - 11 (Total HP- 42 HP) with above specifications & as per drawings - Terrace Floor

1

-

-

... More
Supplying and fixing FP sheet steel enclosure on surface/ recess along with 40amps 415 volts FP Isolator complete with connections, testing and commissioning etc. as required.

48

-

-

... More
SITC of Lockable off push button near pumps & CT

15

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. - 3C x 06sq.mm Al. Cable

125

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. - 3C x 04sq.mm Al. Cable

125

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. - 4C x 25sq.mm Al. Cable

20

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. - 4C x 16sq.mm Al Cable

15

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. - 4C x 06sq.mm Al. Cable

80

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. - 4C x 04sq.mm Al. Cable

800

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor, A2XFY power cable confirming to IS 7098 (part 1) ammended upto date. - 3C x 1.5sq.mm shielded armoured Cu. cable

200

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. - Upto 35 sq. mm (clamped with 1mm thick saddle)

955.5

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. - Upto 35 sq. mm (clamped with 1mm thick saddle)

409.5

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.- 3C x 06sq.mm

16

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.- 3C x 04sq.mm

8

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.- 4C x 25sq.mm

22

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.- 4C x 16sq.mm

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.- 4C x 06sq.mm

10

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.- 4C x 04sq.mm

118

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.- 3C x 1.5sq.mm

16

-

-

... More
Supply and laying earthing for various equipments and motors. - Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required

105

-

-

... More
Supply and laying earthing for various equipments and motors. - Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required

20

-

-

... More
Additional Works Under Deck Insulation - For ICU, Operation Theatre: Supply & fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3

1300

-

-

... More
Roof(inside) insulation for exposed slabs/walls: Supply & fixing of 12 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3

750

-

-

... More
BUILDING MANAGEMENT SYSTEM SITC of Central core Computer - PC (Intel i7 Processor), 8 GB RAM, 2 GB Graphics card, DVD Writer, 22" LED monitor, 1 TB HDD, Microsoft mouse, Keyboards, 2 serial, 1 parallel port/KB, Windows 8 operating system , antivirus software

1

-

-

... More
SITC of Graphical Software complete to cater to hardware points as specified in the Data Point Summary as well as Third Party Software Integrated Systems. System Controller to interface field level controllers to IBMS Workstation

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BACnet shown on BACnet explorer) - Chiller System - 3 Chiller (50 points/chiller)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BACnet shown on BACnet explorer) - Secondary Pumps System (10 Points/Pump)

1

-

-

... More
SITC of Interface for integrating Third Party Systems. (All Systems to provide data on MODBUS RTU with values shown on MODSCAN or BACnet shown on BACnet explorer) - Variable Frequency Drives for AHU's (10 Points per VFD)

1

-

-

... More
SITC of Controls for Chiller System - Networkable DDC Controllers as per Data Point Summary (1- 5) with enclosure with all necessary wiring and accessories

1

-

-

... More
SITC of Controls for Chiller System - Immersion Type Temperature Sensor

4

-

-

... More
SITC of Controls for Chiller System - Outside Air Temperature & RH Sensor

1

-

-

... More
SITC of Controls for Chiller System - Level Switch for expansion tank (2 point)- (depth of tank:1mtr.)

1

-

-

... More
SITC of Controls for Chiller System - Differential Pressure Switch

8

-

-

... More
Control for Air Handling Units : Air Handling Units - 25 Nos.: Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC

13

-

-

... More
Control for Air Handling Units : Air Handling Units with Fine filter- 8 Nos.: Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 2 AHU / DDC

4

-

-

... More
Control for Air Handling Units : Air Handling Units (OT) - 7 Nos.: Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC - For OT

7

-

-

... More
Control for Air Handling Units : AHU WITH HEAT RECOVERY WHEEL - 1 Nos: Supply, Installation, testing & commsssioning of the DDC Controllers with enclosure with all necessary wiring and accessories, consider 1 AHU / DDC

1

-

-

... More
Supply, Installation, testing & commsssioning of Differential Pressure Switch across AHU filter, Pre filter, fine filter and Hepa filter as required

56

-

-

... More
Supply, Installation, testing & commsssioning of Return air Temperature Sensor

42

-

-

... More
SITC of Flexible Bare Copper Conductor, PVC Insulated, Cross Laid Up, Overall Aluminium Mylar Tape Shielded along with ATC Drain Wire PVC Outer Sheath BMS Cables - 2 Core 1.0 sq.mm. shielded FRLS armoured cable

500

-

-

... More
SITC of Flexible Bare Copper Conductor, PVC Insulated, Cross Laid Up, Overall Aluminium Mylar Tape Shielded along with ATC Drain Wire PVC Outer Sheath BMS Cables - 4 Core 1.0 sq.mm. shielded FRLS armoured cable

750

-

-

... More
SITC of Flexible Bare Copper Conductor, PVC Insulated, Cross Laid Up, Overall Aluminium Mylar Tape Shielded along with ATC Drain Wire PVC Outer Sheath BMS Cables - 8 Core 1.0 sq.mm. shielded FRLS armoured cable

750

-

-

... More
SITC of Communication Cabling - 2 Core 1.5 sq.mm. shielded FRLS armoured cable or CAT5E armoured cable

650

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

300

-

-

... More
SITC of Power Cable - 3 C x 2.5 Sq.mm., ATC Armoured Cable

50

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

50

-

-

... More
PART-B FIRE FIGHTING WORKS

-

-

-

... More
MAIN PUMP - ELECTRICAL Supply, installation, testing and commissioning of Horizontal End Suction Fire Hydrant Pump Set: Electrical Driven, Capacity: 2280 LPM at 75Mtr, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal coupled to High Efficient, IE-3 Rated, Squirrel Gauge Induction Electric Motor, suitable HP, 3Ph, 3000 RPM, TEFC, complete with M.S. foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement, Proper Earthing etc. Works should be Completed as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

1

-

-

... More
SPRINKLER PUMP - ELECTRICAL Supply, installation, testing and commissioning of Horizontal End Suction Fire Sprinkler Pump Set: Electrical Driven, Capacity: 2280 LPM at 75Mtr, conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal coupled to High Efficient, IE-3 Rated, Squirrel Gauge Induction Electric Motor, suitable HP, 3Ph, 3000 RPM, TEFC, complete with M.S. foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, anti-vibration mounts, as per requirement, Proper Earthing etc. Works should be Completed as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

1

-

-

... More
DIESEL PUMP Supply, installation, testing and commissioning of Stand By/Back Up Fire Pump, Horizontal, End Suction Pump, Engine Driven, suitable for Automatic operation and consisting of the following and complete in all respect as required; Capacity: 2280 LPM at 75Mtr. Head conforming to IS 1520, with Bronze Impeller, S. S. Shaft, Mechanical Seal, coupled to High Efficient Radiator Cooled Diesel Engine, suitable HP, 1800/2150 RPM, and with Control Panel with Auto Starting Facility, by activation of concerned Pressure Switch and thro. 12V/24 V Electric Starter, Battery with adequate rating and with Battery Charger, Battery Leads, Diesel Tank for 6 hrs operation, exhaust pipe extended up to Roof Top of highest building near by as per site condition & Confirming to CPCB Norms, duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, complete with M.S. foundation, foundation bolts, compound gauge, water re-circulation arrangement, pressure relief valve, and all other necessary fixing accessories,Proper Earthing all as per Technical Specifications.

1

-

-

... More
JOCKEY PUMP Supply, installation, testing and commissioning of Jockey Pump: Electrical Driven, Capacity: 180 LPM at 75 Mtrs. Head, Vertical Multi Stage Inline Pump with S.S Impeller, Mechanical Seal, and with High Efficient IE-3 Rated Squirrel Gauge Induction Motor, Suitable HP, 3000 RPM, TEFC, complete with foundation, foundation bolts, anti vibration pad, and all other necessary fixing accessories, Proper Earthing etc.. Works should be completed as per as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions.

2

-

-

... More
MOTOR CONTROL PANEL Providing, fixing, testing and commissioning of Common Control Panels for Main Fire Pumps, Sprinkler pump & Jockey Pump, complete as per Technical Specifications and as detailed below. Fabricate, supply, convey, install, test and commission cubicle type, dust and vermin proof, floor mounted, front operated Control Panel, as per IS: 8623 (with latest amendments) fabricated with 2 mm. / 14gauge thick CRCA sheet as per approved design and requirement, IP: 54 protection, complete with Main Isolator, Bus Bar Chamber, Volt Meter, Ammeter, Individual Star- Dealt Starters for Main Pumps, DOL Starter for Jockey Pump, Contactors, Auxiliary Contacts, Timers, Indicating Lamps, Fuses, Auto / Manual Selector Switches for all Fire Pumps, Manual On /Off Buttons for Jockey Pump & Manual On Buttons for Main Pumps, all internal wiring etc. The price for Control Panel shall be inclusive of, Control Cabling, in Steel Conduits, for automatic starting of Main Pumps & Automatic start and stop for Jockey Pump and Earthing of the Panel, all as per Technical Specifications, Prevailing Rules, Standards, Requirement and Site Conditions. (Detailed Technical Specification Attached)

1

-

-

... More
Supply and Laying of below sized XLPE insulated PVC sheathed Aluminium conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3C x 70 sq mm

30

-

-

... More
Supply and Laying of below sized XLPE insulated PVC sheathed Aluminium conductor armored cabling to the incoming and outgoing of fire pump panel including necessary termination, glanding, necessary connections etc 3C x 10 sq mm

30

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 70 sq. mm (35mm)

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 X 10 sq. mm (22mm)

4

-

-

... More
AIR CUSHION VESSEL Supplying, Installation, Testing & Commissioning of air cushion tank (air vessel) of continuous welded construction, fabricated out of atleast 8mm thick steel with dished ends, and supporting legs, Capable of carrying 15Bar Pressure, 250mm dia & 1200mm high complete with necessary air release valve, safety valve, pressure gauge, flange connection to the wet riser piping with necessary piping to meet the functional requirement of the system.

1

-

-

... More
STRAINER Supplying,installing,testing and commissioning of strainer with SS mesh,suitable flanges,nuts,bolts,gaskets etc. 200mm

2

-

-

... More
AIR RELEASE VALVE Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including necessary accessories and connections.

5

-

-

... More
PRESSURE GAUGE Supply, installation, testing and commissioning of 4" dia. Pressure Gauge, with ISI Mark or of equivalent International Standards.Weather / Water Proof, Type with gunmetal /brass shut off cock.

7

-

-

... More
PRESSURE SWITCH Supply, installation, testing and commissioning of industrial type pressure switch having 1/4" BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SDPT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC etc. complete as required.

4

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc...as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for Suction Line for Fire Pumps shall be inclusive of 600 x 600mm Vortex Plates, inside the Water Tanks, fabricated from 10mm. M.S. Plate with approved Paint Protection, all as per Technical Specifications & Tender Drawings. a) 200 mm Dia

35

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc...as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for Suction Line for Fire Pumps shall be inclusive of 600 x 600mm Vortex Plates, inside the Water Tanks, fabricated from 10mm. M.S. Plate with approved Paint Protection, all as per Technical Specifications & Tender Drawings. b) 150 mm Dia

15

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc...as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for Suction Line for Fire Pumps shall be inclusive of 600 x 600mm Vortex Plates, inside the Water Tanks, fabricated from 10mm. M.S. Plate with approved Paint Protection, all as per Technical Specifications & Tender Drawings. c) 80 mm Dia

15

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc...as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes.The Price for Suction Line for Fire Pumps shall be inclusive of 600 x 600mm Vortex Plates, inside the Water Tanks, fabricated from 10mm. M.S. Plate with approved Paint Protection, all as per Technical Specifications & Tender Drawings. d) 25 mm Dia

20

-

-

... More
BUTTERFLY VALVE Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, Gear Operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Tamper Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. a) 200 mm Dia

2

-

-

... More
BUTTERFLY VALVE Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. b) 150 mm Dia

3

-

-

... More
BUTTERFLY VALVE Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. c) 80 mm Dia

2

-

-

... More
SLUICE VALVE Providing, fixing, testing and commissioning of SLUICE VALVE Ductile Iron, PN-16, TYPE: RISING STEM, PROD STD: IS 14846, Body-DUCTILE IRON (ASTM A 536), SEAT: Cu-Alloy, Stem: SS.410, Ends :FLANGED AS PER IS 1538/PN 16, PRESS. RATING : BODY: 21kg/cmsq, SEAT: 16 kg/cmsq. and with required matching Flanges, nuts, bolts etc. complete.- 200 mm

2

-

-

... More
NON-RETURN VALVE Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to Indian Standards with nuts, bolts etc. complete. a) 200 mm Dia

2

-

-

... More
NON-RETURN VALVE Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to Indian Standards with nuts, bolts etc. complete. b) 150 mm Dia

3

-

-

... More
NON-RETURN VALVE Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to Indian Standards with nuts, bolts etc. complete. c) 80 mm Dia

2

-

-

... More
BALL VALVE Providing, fixing, testing and commissioning of Forged Ball Valve, PN-20 gunmetal /cast alloy, including necessary accessories and connections. D) 25 mm Dia

2

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc...as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. a) 150 mm Dia

140

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc...as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. b) 100 mm Dia

140

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc...as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. c) 80 mm Dia

15

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc...as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. d) 50 mm Dia

140

-

-

... More
UNDER GROUND PIPING Providing, fixing, pressure testing and commissioning of Underground Fire Hydrant Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Butt Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, laying in trenches, providing thrust blocks, providing higher sizes of Protective Sleeve / Pipes and RCC encasement, all as per requirement and to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting systems and bitumen based flexible wrapping, all as per Technical Specifications a) 150 mm Dia

50

-

-

... More
UNDER GROUND PIPING Providing, fixing, pressure testing and commissioning of Underground Fire Hydrant Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Butt Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, laying in trenches, providing thrust blocks, providing higher sizes of Protective Sleeve / Pipes and RCC encasement, all as per requirement and to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting systems and bitumen based flexible wrapping, all as per Technical Specifications b) 100 mm Dia

800

-

-

... More
UNDER GROUND PIPING Providing, fixing, pressure testing and commissioning of Underground Fire Hydrant Pipe Work with Heavy Duty (Class-C) Mild Steel Pipes, confirming to IS: 3589/1239 Part - I (wherever applicable) and with Heavy Duty Black Ductile Iron Screwed Fittings for Pipes up to 50mm. dia. and Butt Welded Fittings, for pipes above 50mm. dia. confirming to IS:1239 Part - II, such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, welding, joining, laying in trenches, providing thrust blocks, providing higher sizes of Protective Sleeve / Pipes and RCC encasement, all as per requirement and to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting systems and bitumen based flexible wrapping, all as per Technical Specifications c) 80 mm Dia.

90

-

-

... More
BUTTERFLY VALVE Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. a) 150 mm Dia

1

-

-

... More
BUTTERFLY VALVE Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. b) 100 mm Dia

2

-

-

... More
BUTTERFLY VALVE Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Maximum Working Pressure 16 Bar, standard lever operated type, confirming to BS:5155 / ASTM A-536, grade 65-45-12, with Supervisory / Micro Switch, as per Technical Specifications and with required matching Flanges, nuts, bolts etc. complete. c) 80 mm dia.

18

-

-

... More
NON-RETURN VALVE Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to Indian Standards with required companion flanges, nuts, bolts etc. complete. a) 150 mm Dia

1

-

-

... More
NON-RETURN VALVE Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to Indian Standards with required companion flanges, nuts, bolts etc. complete. b) 100 mm Dia

1

-

-

... More
HYDRANT VALVE Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark, Stainless Steel-304 body with 63mm. oblique instantaneous single outlet, 75mm. N.B. flanged inlet, Stainless Steel -304 spindle, complete with PVC blank cap, G.I. chain etc.

35

-

-

... More
BRANCH PIPE Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark.

35

-

-

... More
FIRE HOSE Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fiber. conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg/Cm2 and Burst Pressure 38 Kg/Cm2. The Fire Hose shall be with IS: 636 Type-A marking and 63mm. dia.x15Mtr.long with pair of 63mm. male and female instantaneous couplings, Stainless steel-304, having IS: 903 mark and duly S. S. wire wounded.

70

-

-

... More
HOSE REEL Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided /rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm. isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set.

17

-

-

... More
BALL VALVE Providing, fixing, testing and commissioning of Forged Ball Valve, PN-20 gunmetal /cast alloy, including necessary accessories and connections. a) 25 mm Dia

17

-

-

... More
HOSE CABINET Supply, installation, testing and commissioning of M.S. CRCA sheet fabricated 16 SWG Fire Hydrant hose boxes suitable for storing 2 Nos.15M hoses and 1 No. Branch pipe of 63mm dia size. Boxes will be duly painted with two coats zinc primer and finish fire red colour enamel paint outside with locking arrangement for single leaf front glass doors having 4mm thick glass, complete as per specifications.

17

-

-

... More
HOSE CABINET Supply and fix at site in position Weather Proof Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate Two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and pole for mounting, all as per requirement.

18

-

-

... More
AIR RELEASE VALVE Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 20mm. BSP threaded male inlet, including necessary accessories and connections.

2

-

-

... More
FIRE BRIGADE INLET Supply, installation, testing and commissioning of Fire Brigade Inlet Breeching, C.I. body, having 4 Gunmetal, 63mm. male instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 4 nos. of rubber blank caps and G.I. chains.

2

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc.. as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. a)150 mm Dia

60

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc.. as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. b)100 mm Dia

450

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc.. as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. c) 80 mm Dia

500

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc.. as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. d) 65 mm Dia

650

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc.. as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. e) 50 mm Dia

400

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc.. as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. f) 40 mm Dia

1200

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc.. as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. g) 32 mm Dia

200

-

-

... More
ABOVE GROUND PIPING Providing, laying, fixing and jointing in position GI 'C' class pipes with Screwed Fittings for Pipes up to 50mm dia. and but Welded Fittings for pipes above 50mm dia. conforming to IS 1239 Part-1 with malleable specials confirming to IS:1239 part-2 such as elbows, bends, couplings, tees, reducers etc.. as required including testing hydraulically to 1.5 times the working pressure painting with one coat of anticorrosive paint and two coats of red enamel paint etc complete with fabricating & fixing MS angle, flats, channels fabricated brackets / supports for supporting the pipes with 10mm 'U' bolts,hitech type brackets for pipes. h) 25 mm Dia

2400

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type, confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. a) 150 mm dia.

13

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type, confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. b) 100 mm dia.

7

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, PN-16, slim seal, standard lever operated type, confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. c) 50 mm dia.

17

-

-

... More
SPRINKLER BULB Providing, fixing, testing and commissioning of Standard Coverage , Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings. Pendant Type, 68 / 79 Degree C Rating.

1450

-

-

... More
SPRINKLER BULB Providing, fixing, testing and commissioning of Standard Coverage , Quick Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings. Upright Type, 68 Degree C Rating.

1230

-

-

... More
ROSETTE PLATE Providing & Fixing 2 Piece Chrome Plated Friction Fit recessed escutcheon for pendant sprinklers, as per requirement.

1200

-

-

... More
Providing, Fixing, Testing and Commission Flexible Sprinkler Hose; UL Listed, FM Approved, 25mm. (1") BSP Male Inlet, 15mm. (1/2") NPT Female Outlet, Braided, Working Pressure 13.8 Bar, length: 1000 mm, and with all connecting systems and accessories.

1200

-

-

... More
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.

300

-

-

... More
SITC of Networkable Addressable Fire Alarm Control Panel. The panel should be equipped with 7 numbers of loops considering 20% spare capacity in each loop and expandable upto 9 loops. Each loop shall have a capacity of maximum 252 analog addressable devices. The panel shall work in degrade mode in case of CPU failure. Visual Display Unit (VDU) preferably 640 character LCD display, Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition. The panel shall be Integrated Digital PA and VA system with adequate zone control and accessories. The FACP and all accessories shall be UL Listed and FM Approved.

1

-

-

... More
Supply, installation, testing and commissioning of active repeater panel. It shall be powered from the Main FACP & shall be supplied with necessary interface cards for connecting to FACP. The Panel shall have minimum 2 x 40 characters back lit LCD display with necessory battery backup for 24 hrs operation. The panel shall be UL Listed and FM Approved.

1

-

-

... More
Addressable Manual Call Point (Pull down / Break Glass Type). AAddressing shall be with user friendly Rotary and dip switch/electronically addressables... The MCP shall be UL Listed and FM Approved.

26

-

-

... More
MULTI SENSOR SMOKE DETECTORS SITC of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 2% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall adapt to its environment by utilizing a built-in microprocessor to determine its environment and choose the appropriate sensing settings for early detection and reduction in false alarm. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal/dip switch/Electronically Addressable. The detector shall be UL Listed and FM Approved. (a) Above ceiling

435

-

-

... More
MULTI SENSOR SMOKE DETECTORS SITC of Addressable Multi-criteria Photo-Thermal Detector with sensitivity range of 0.5 to 2% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall adapt to its environment by utilizing a built-in microprocessor to determine its environment and choose the appropriate sensing settings for early detection and reduction in false alarm. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal/dip switch/Electronically Addressable. The detector shall be UL Listed and FM Approved. (b) Below ceiling

572

-

-

... More
SITC of Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min. The detector shall have LED for 360 deg viewing. Addressing shall be with user friendly Rotary and dip switch/electronically addressables.The detector shall be UL Listed, FM Approved.

7

-

-

... More
SITC of Addressable Outdoor Strobe, Red Color with selectable multi candela with min 30 Cd to max 115 Cd. The Strobe shall include all modules, accessories, power supplied etc as required. The Strobe shall be UL Listed and FM approved.

6

-

-

... More
SITC of Addressable Sounder cum Strobe rated at 75 dBA @ 3m for Audible annunciation and 75cd flashintg at 1 Hz for visual indication. The sounder shall be UL Listed and FM approved.

26

-

-

... More
SITC of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes. The control module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal/Dip switches/Electronically Addressable. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved.

26

-

-

... More
SITC of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device. Addressing shall be with user friendly rotary decimal/DIP switches/Electronically Addressable. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved.

53

-

-

... More
SITC of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall provide DPDTcontact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device. Addressing shall be with user friendly rotary decimal/DIP switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved.

20

-

-

... More
SITC of Addressable Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The Module shall be UL Listed and FM Approved.

66

-

-

... More
Providing, fixing, testing and commissioning of External Power Supply Unit, 24V, 2Amps DC with Battery Backup, for sounders, sounder bases, Strobes etc…..

3

-

-

... More
Supply installation testing and commissioning of Response Indicator for detectors located in False Floor and False ceiling.

450

-

-

... More
Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armored Cables with Red Colour, as per Technical Specifications. (Approx. Quantity)

6500

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with above 20 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System. The control cabling from flow switches to Fire Sprinkler Annunciating Panel shall be measured separately.

20

-

-

... More
TALK BACK ANNOUNCING CONSOLE Supply, installation, testing & commissioning of microprocessor based talk back announcing console suitable for selecting 16 Zone, having key pad for zone selection, LED indication, gooseneck microphone for making announcement, switching unit for talk back system, main distribution box for talk back system, 100W booster amplifier & wall mounted talk back unit having press to talk facility with speaker, switch etc in power CRCA sheet enclosure etc, as required. (a)  100W amplifier capable of 16 zone

1

-

-

... More
TALK BACK ANNOUNCING CONSOLE Supply, installation, testing & commissioning of microprocessor based talk back announcing console suitable for selecting 16 Zone, having key pad for zone selection, LED indication, gooseneck microphone for making announcement, switching unit for talk back system, main distribution box for talk back system, 100W booster amplifier & wall mounted talk back unit having press to talk facility with speaker, switch etc in power CRCA sheet enclosure etc, as required. (b)  Talk back speaker

19

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (a) Fire Lift sign board (12" x 4")

18

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (b) Passenger Lift sign board (12" x 4")

32

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (c) Fire Duct sign board (12" x 4")

36

-

-

... More
Supply and install in position Sign Boards with in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (d) Fire Exit Light, Laser type, with High Glow LED, size: 12” x 6” Size, Ceiling Mounting type with hanging clamps, on/off switch, Red/ Green Colour option, power consumption: 18 Watt, with 2 Hr. battery backup.

9

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (e) Electrical Duct sign board (12" x 4")

25

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (f) Main Staircase sign board (12" x 4")

18

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (g) Fire Staircase sign board (12" x 4")

9

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (h) Floor Display sign board (12" x 4")

9

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (i) Fire Assembly Point (16" x 16")

2

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (j) Pump Room sign board (12" x 4")

1

-

-

... More
Supply and install in position Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, self adhesive vinyl painted foam board in photolumiscent material complete vide technical specifications with mirror fasteners. Sizes and mounting height of the board shall be as per technical specification, complete with mirror fasteners. (k) Fire Control Room sign board (12" x 4")

1

-

-

... More
Supply, installation, testing & commissioning of Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.ABC Dry Chemical Store Pressure Type-4 Kg.

60

-

-

... More
Supply, installation, testing & commissioning of Clean Agent Modular Type Fire Extinguisher 4Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with charge of HFC Blend A, It is a blend of Hydro Fluoro Carbon and organic detossificant essence P26. The sprikler body will comprise of temperature sencitive quartsoid bulb of temperature rating of 68 deg C. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling.

7

-

-

... More
Supply, installation, testing & commissioning of 2hr Fire rated door 46mm thick steel door 1200mmx2100mm size,1.2mm thick GI sheet sandwiching with FR insulation material in between.The door frames are manufactured from 1.5mm thick GI sheet pressed from double rebate profile of size 143x57 mm the door frame and single leaf door is finished with powder coated of approved shade, Fire door's are inclusive of fixed panels, with clear fire ressitant glass panes 6mm Thick, panic bar/latch(Double Point) fitted with a single body, latch & Lock on back side of Panic Bar, Door closer, Dash fastner and other accessories required for the full functioning of the Fire rated Doors.

26

-

-

... More
FIRE SEALANT APPLICATION Scope:Medium to large (more than 4" gaps) (Considering 65 mm thk mortar) Providing Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479 (American) standards, for horizontal openings in floors or slabs after passing service lines like Metal/Plastic Pipes, HVAC Duct with combustibel/Non Combustible insulations. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be UL listed & classified and shall bear the UL approval logo on the packing. Firestop installation should be done by Accredated Firestop Speciality Contractor and in accordance with Vendor guidelines.

15

-

-

... More
FIRE SEALANT APPLICATION Providing High performance intumescent firestop sealant that helps protect combustible penetrations for up to 4 hours fire rating in accordance to UL 1479 (American) standards. Surface burning characteristics according UL 723 (ASTM E84-96). Flame spread index 0 and smoke development index 5. The sound transmission classification for this product according ASTM E 90-99 is 56 (STC Rating). It High is mold and mildew resistant and the performance is Class 0 according ASTM G-21. Movement capability approx.. 5% (ISO 11600) and the average volume shrinkage is 24% according ASTM C1241 and meets LEED requirements for indoor environmental quality credit (4.1 and 4.2) with a VOC content of 9 g/l. product should also Seismic tested on mechanical performance, smoke and fire-ratings. Firestop installation should be done by Accredated Firestop Speciality Contractor.

50

-

-

... More
PUBLIC ADDRESS AND VOICE EVACUATION SYSTEM SITC of 8 zone IP based, digital Voice Alarm controller expandable upto 100 zones. The voice alarm controller should be able to connect directly over Ethernet. It should have functions like the audio playing, zone control, fault monitoring, log recording, volume control and amplifier switchover. The Voice alarm controller should also have the following functions: . 100 Priorities . Time schedule broadcasts . Capable of amplifier redundancy . 8 trigger inputs/outputs. The controller shall be able to integrate with Fire Alarm system in the building to enable phased evacuation. It should also have the provision to configure Hospital codes like Code Blue, Red, Pink etc and should be configurable on the paging station for single touch broadcasting.

2

-

-

... More
PUBLIC ADDRESS AND VOICE EVACUATION SYSTEM SITC of IP based Networkable touch screen paging station for selection of zones, supervision of system status, setting of scheduled broadcasts with the following functions: . Built-in monitoring loudspeaker . Detachable goose-neck microphone . LCD touchscreen display . Audio input

2

-

-

... More
PUBLIC ADDRESS AND VOICE EVACUATION SYSTEM SITC of 480 W Power Amplifier Speaker Output 4~16Ω Low-Z output 480W,70V(10.7Ω) 100V (21.7Ω) Frequency response of 60 Hz~15 kHz ( ± 3 dB ), S/N >80dB, Protection like - AC Fuse × 15 A AC FUSE×1, Current limiter, short circuit and thermal protection circuits. It should have D/A converter and all accessories required.

8

-

-

... More
PUBLIC ADDRESS AND VOICE EVACUATION SYSTEM SITC of Metal Grille 6W Ceiling Speaker with max SPL1M/1W 96dB . Frequency response of 80Hz-20KHz with a dispersion angle of 160 deg. The speaker should have tappings at 6W/3W/1.5W

205

-

-

... More
PUBLIC ADDRESS AND VOICE EVACUATION SYSTEM SITC of 6W Wall mount with max SPL1M/1W 96dB . Frequency response of 160Hz-20KHz. The speaker shoud have tappings at 6W/3W

25

-

-

... More
PUBLIC ADDRESS AND VOICE EVACUATION SYSTEM SITC of 10W Wall mount with max SPL1M/1W 96dB . Frequency response of 160Hz-20KHz. The speaker shoud have tappings at 10W/5W

4

-

-

... More
PUBLIC ADDRESS AND VOICE EVACUATION SYSTEM Supply, Laying & Termination of 2Cx1.5sq.mm FRLS type,flexible copper cable.

7000

-

-

... More
PUBLIC ADDRESS AND VOICE EVACUATION SYSTEM Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm

5000

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

90

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

120

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required. 150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as required. 300 mm width X 50 mm depth X 1.6 mm thickness

4

-

-

... More
MINOR CIVIL WORKS: Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in- charge - Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

1

-

-

... More
MINOR CIVIL WORKS: Demolishing R.C.C. work manually/ by mechanical means including cutting and stacking of steel bars and disposal of unserviceable material within 50metres lead as per direction of Engineer - in- charge.

1

-

-

... More
MINOR CIVIL WORKS: Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin- charge.

2

-

-

... More
MINOR CIVIL WORKS: Demolishing brick/ block work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge-In cement mortar

1

-

-

... More
MINOR CIVIL WORKS: Making good abandoned drill holes in concrete including cutting the patch in proper shape, raking out joints and preparing, plastering the wall surface with non-shrinkage grout/ polymer modified self curing mortar of approved make, including disposal of rubbish, all complete as per the direction of Engineer-In- Charge

2

-

-

... More
MINOR CIVIL WORKS: Making the opening in brick/ block masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, and wherever required etc complete, to match existing surface as per approved drawing i/c disposal of rubbish, all complete as per directions of Engineer-In-Charge

20

-

-

... More
MINOR CIVIL WORKS: Core cutting for following sizes of Pipes, in following RCC Structures, including grouting the holes with GP2 Conbextra or approved equal. In floor/roof slab, thickness 150mm. (approx.) 40mm. O.D.

2

-

-

... More
MINOR CIVIL WORKS: Core cutting for following sizes of Pipes, in following RCC Structures, including grouting the holes with GP2 Conbextra or approved equal. In floor/roof slab, thickness 150mm. (approx.) 50mm. O.D.

2

-

-

... More
MINOR CIVIL WORKS: Core cutting for following sizes of Pipes, in following RCC Structures, including grouting the holes with GP2 Conbextra or approved equal. In floor/roof slab, thickness 150mm. (approx.) 63mm. O.D.

2

-

-

... More
MINOR CIVIL WORKS: Core cutting for following sizes of Pipes, in following RCC Structures, including grouting the holes with GP2 Conbextra or approved equal. In floor/roof slab, thickness 150mm. (approx.) 110mm. O.D.

2

-

-

... More
MINOR CIVIL WORKS: Core cutting for following sizes of Pipes, in following RCC Structures, including grouting the holes with GP2 Conbextra or approved equal. In floor/roof slab, thickness 150mm. (approx.) 150mm. O.D.

2

-

-

... More
MINOR CIVIL WORKS: Core cutting for following sizes of Pipes, in following RCC Structures, including grouting the holes with GP2 Conbextra or approved equal. In floor/roof slab, thickness 150mm. (approx.) 200mm. O.D.

2

-

-

... More
Providing and fixing anchor bolts in concrete including drilling, necessary bending, hooking/ tying in position and chemical grouting etc complete as per approved drawing and specifications. 12mm. O.D.

5

-

-

... More
Earth work excavation in all kinds of soil for foundation, trenches, grade beams, etc including strutting, shoring and packing cavities wherever required, bailing /pumping out water from any depth, if required and getting out the excvated soil and back filling the soil as required in layers not exceeding 20 cm in depth, consolidating each layer by watering, ramming etc and disposing of surplus excavated earth, stacking of serviceable stones, disposal of unserviceable materials away from site with initial lead upto 50m and lift upto 1.5m including breaking clods, watering, ramming and sectioning of soil bank etc complete as directed by the Engineer-in-charge.

2

-

-

... More
Providing and laying 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 40 mm nominal size) machine mixed and properly consolidated with hand rammers, including the cost and conveyance of all materials, labour, centering and shuttering, curing, lead lift etc complete at all levels, including anchor bolt fixing, making good surfaces etc and as directed by Engineer-in-charge: for machine foundation bases, pedestals etc

2

-

-

... More
Reinforcement steel - Providing and fixing reinforcement for RCC work with Thermo-Mechanically Treated (TMT) bar of various diameters and grade of steel as specified below confirming to IS 1786 in grade Fe-415 or higher grade BS specification including cutting, bending, hoisting, fabricating and placing in position according to drawings and binding the reinforcement with galvanised annealed binding wire of double fold of 18 guage and providing PVC cover blocks for placing the reinforcement in position and for maintaining the cover specified and or according to relevant IS or equivalent BS code. Note: Unless noted otherwise the measurements in accordance with IS1200 or equivalent BS shall be provided. Cover block, wastage and binding wire will not be measured and shall be included in the quoted rates.

250

-

-

... More
Masonry with solid concrete blocks in foundation and plinth in blocks of size 30x20x15cm, grade D of block density not less than 1800 kg/cum and average compressive strength of 4 N/mm2 and minimum strength of individual blocks 3.2 N/mm2 (as specified in IS 2185 part I 1979 Grade C) blocks constructed with cement mortar 1:6 for 20cm thick walls including cost and conveyance of all materials to site, labour charges, hire and labour for scaffolding, curing etc complete.

2

-

-

... More
Masonry with solid concrete blocks above plinth, blocks of size 30x20x15cm, grade D of block density not less than 1800 kg/cum and average compressive strength of 4 N/mm2 and minimum strength of individual blocks 3.2 N/mm2 (as specified in IS 2185 part I 1979 Grade C) blocks constructed with cement mortar 1:6 for 20cm thick walls including cost and conveyance of all materials to site, labour charges, hire and labour for scaffolding, curing etc complete;

1

-

-

... More
Internal plastering with cement mortar 1:5, 12mm thick one coat over the surfaces of cement block work /brick work including providing ckicken mesh or PVC net making plaster grooves where ever necessary in all heights including cost and conveyance of all materials, labour charges, curing scaffolding etc complete in all floors.

10

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer

10

-

-

... More
Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.

10

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.- Chequered plates, in stringers, treads, landings etc. of stair cases or wherever required etc all complete

1000

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.