INKEL Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

INKEL Limited - INKEL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date2 Feb 2024
Closing Date22 Feb 2024
Tender Amount₹ 44,19,01,219 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Routine test(Test Load 1.5 times the Safe capacity) up to 110 tonne capacity(For 700mm dia)

3

-

-

... More
Earth Work

-

-

-

... More
2.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil

5831.74

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

800.36

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

807.05

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

2669.41

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

50

-

-

... More
2.16.2 : Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth exceeding 1.5 m but not exceeding 3 m

150

-

-

... More
2.10.1.3 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm

43

-

-

... More
Supplying and packing 20mm stone aggregate between the retaining wall and earth fill along the building perimeter including watering, ramming, consolidating and dressing complete including lead, lift, stacking, transportation etc. as directed by the Engineer in charge - for retaining wall

50.53

-

-

... More
60.7.2 : DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.

27.77

-

-

... More
Extra for conveying and depositing surplus earth beyond 50m and upto 1Km including loading and unloading as directed by Engineer- in-Charge.

3962.66

-

-

... More
Conveying and depositing surplus earth for every additional 1Km lead and part thereof including loading and unloading as directed by Engineer- in-Charge.

1500

-

-

... More
Plain cement concrete works

-

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

215.87

-

-

... More
Reinforced cement concrete and Shuttering work

-

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design). All work upto plinth level

97.75

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 330 kg/cum and no payment shall be made for extra cement however contractor shall be bound to use required cement quantity as per the approved mix design). All work above plinth level upto floor V level

355.63

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate,retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note :- Minimum Cement content is 340 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design).All work upto plinth level

825.6

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Min cement content is 340kg/cum and no payment shall be made for extra cement).All work above plinth level upto floor V level

2433.8

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:-Minimum Cement content is 360 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design.All work upto plinth level

19.12

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:-Minimum Cement content is 360 kg/cum and no payment shall be made for extra cement if required, however contractor shall be bound to use required cement quantity as per the approved mix design.All work above plinth level upto floor V level

718.1

-

-

... More
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).

7.02

-

-

... More
5.38 : Extra for R.C.C. /B.M.C/R.M.C. work above floor V level for each four floors or part thereof.

1266.41

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

1082.9

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

3161.13

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

6302.47

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

12475.83

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

4447.05

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

545.85

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

899.32

-

-

... More
5.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)

6654.87

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

193469.26

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

605586.7

-

-

... More
Sub Head- Block Work

-

-

-

... More
6.47 : Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

1849.97

-

-

... More
6.5 : Extra for brick work/ AAC block masonry/Tile brick masonry in super structure above floor V level, for each four floors or part thereof by mechanical means.

708.88

-

-

... More
6.3.2 : Brick work with common burnt clay machine moulded perforated bricks of classdesignation 12.5 conforming to IS: 2222 in superstructure above plinth level up tofloor five level in cement mortar 1:6 (1 cement : 6 coarse sand):With Modular bricks

36.55

-

-

... More
50.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete

57.41

-

-

... More
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

71.63

-

-

... More
50.6.2.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete

24.9

-

-

... More
7.1.1 : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)

208.79

-

-

... More
7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)

68.53

-

-

... More
Joinery Works

-

-

-

... More
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

1932.66

-

-

... More
25.2 : Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub-head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories 1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr” 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.” 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range upto 2000 ml” 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm” 5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml”

214.74

-

-

... More
Providing and supplying Single glazing comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with SHGC =0.34,U value 3.9 and VLT =34% etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass shall be measured in sqm

214.74

-

-

... More
21.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

4661.96

-

-

... More
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

6820.5

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade II Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides

412.49

-

-

... More
Providing and fixing glazing in aluminium door, window shutters and partitions etc.with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With toughned glass panes of 6 mm thickness with SHGC=0.34 and VLT=34%.

439.38

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With toughned glass of 6mm thickness

35.1

-

-

... More
Providing and fixing pin headed glass in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): glass of 4.0 mm thickness

20.3

-

-

... More
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness

182.36

-

-

... More
21.4.1 : Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors including cost of cutting floors, embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer -in- Charge.With stainless steel cover plate minimum 1.25 mm thickness

132

-

-

... More
21.11.2 : Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.255 x 19 mm

55

-

-

... More
9.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

94

-

-

... More
9.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

376

-

-

... More
9.122.1 : Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

135.3

-

-

... More
50.9.15.2 : Supplying and fixing 300 mm Aluminium aldrop

74

-

-

... More
21.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminium

73

-

-

... More
9.97.1 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm

229

-

-

... More
9.97.2 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm

229

-

-

... More
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

106

-

-

... More
21.18 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

4.8

-

-

... More
Providing and fixing Stainless Steel Corner Patch Lock with Strike Plate of SSS finish for toughened glass door including all necessary fittings Or equivalent.

2

-

-

... More
Providing and fixing Stainless steel D type glass door handle with SSS polished finish of 25mmx450mm size.

2

-

-

... More
9.101.1 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper

132

-

-

... More
9.101.2 : Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

82

-

-

... More
9.106.2 : Providing and fixing PTMT handles with necessary screws etc. complete.150x34x24 mm weighing not less than 26 gms

74

-

-

... More
9.108.2 : Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms

148

-

-

... More
9.100.1 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

264

-

-

... More
9.100.2 : Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm

194

-

-

... More
Supplying and fixing 100mm mortice cylinder lock for aluminium door with following specification. a)Hook bolt has to be made of MS and SS for end plate and strike plate with lock set of size minimum 37mm, back set of min 20mm and hock bolt of min 18mm. b)Cylinder should be made of brass with minimum weight 0.20kg with nickel plated brass key(3 sets) and it should be of 5pin brass tumbler mechanism

149

-

-

... More
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) locking arrangement for sliding windows including necessary screws and fittings of approved make as directed by Engineer-in-charge.

505

-

-

... More
Providing and fixing roller for shutters of sliding aluminium windows with necessary screws etc.complete.As approved by Engineer-in-charge

2020

-

-

... More
Providing and fixing roller for Aluminium sliding door

60

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. 1200mmX2100mm

1

-

-

... More
Providing and fixing of hollow metal door at all levels from ISO 9001-2015 certified manufacturer. All hollow metal general doors with or without vision panel. Pressed galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be double rebate profile of size 143 x 57mm made out of 2.0mm (14gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with bolts. The inside face of the frame face trim to rebate height should be protected with 2.0 mm thick lead line. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the strike jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement &sand slurry necessary for doors on the clear masonry opening.Door leaf shall be 48mm thick fully flush double skin door. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanised steel sheet. The internal construction of the door should be rigid with lead line of 2.0mm thick all across the inside of the exposed surface. In addition the door should have a basic infill steel stiffened special core with necessary reinforcement both on top and bottom. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI Standard. The edges should be interlocked with lock seam. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Approved hardware make : Lawrence / Gallery / Zero.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate should include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule.1500mmX2400mm

2

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1000mmX2100mm

1

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1200mmX2400mm

8

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1500mmX2400mm

5

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.1800mmX2400mm

1

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Doors shall be with vision glass and louver as a part of complete assembly.Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have inbuild grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff.Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be provided as per manufacturers recommendation with a clipon arrangement. The glass should be 5mm clear toughned glass of relavant rating of the door.All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recomended by the manufacturer or engineer.2000mmX2400mm

5

-

-

... More
Frosted film - Supply and installation of 3M make frosted film pattern throughout all the internal glass panels wherever required of approx. 1.5 m height as per the approved pattern.

152.6

-

-

... More
Steel work and Fire Doors

-

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

6616.35

-

-

... More
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

1479.87

-

-

... More
10.16.3 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes

22331.25

-

-

... More
10.25.1 :Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

552.8

-

-

... More
10.25.2 :Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

5570.4

-

-

... More
10.6.2 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.20 mm M.S. laths with 1.20 mm thick top cover

133.92

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

20

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

116.64

-

-

... More
10.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).

19.44

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

3224.01

-

-

... More
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 1200mmx2100mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer,dash fastener and other accessories required for the full functioning of the Fire rated Doors

2

-

-

... More
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 1000mmx2100mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors

6

-

-

... More
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 900mmx2100mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors

1

-

-

... More
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 1500mmx2400mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors

10

-

-

... More
Supply, installation, testing and commissioning of 2hr fire rated fire door of size 1200mmx2400mm with 46mm thick shutter manufactured from 1.2mm thick GI sheet sandwiching with Honey comb insulation material. The door frames manufactured from 1.6mm thick GI sheet pressed from single rebate profile of size 100mmx57mm. The door frame and single leaf door is finished with powder coating of 50 micron approved shade.Fire doors are inclusive of vision panel with 6mm thick 2hr fire rated glass of size 200mmx300mm, panic bar/latch (double point), external lever handle, surface door closer, dash fastener and other accessories required for the full functioning of the Fire rated Doors.

6

-

-

... More
Supply, installation, testing and commissioning of 600mmx1500mm shaft door having 2hr fire rating with 46mm thick Shutter and outer frame of size 100x57mm. Shutter should be manufactured from 0.8mm thick GI sheet sandwiching with Honey comb insulation material. The door frames are manufactured from 1.2mm thick GI sheet. The door frame and single leaf door should be finished with powder coating of 50micron approved shade. Fire doors are inclusive of ball bearing SS hinges, mortice shaft lock and SS flush handle of size 120x40mm etc.as per the direction of Engineer -in charge.

12

-

-

... More
Providing and fixing of Hollow metal doors made of pressed galvanized steel confirming to IS 277 with the following specification. Door frame shall be single rebate profile of size 100 x 57mm made out of minimum 1.20mm (18gauge) thick galvanized steel sheet. Frames shall be butted and field assembled with self tabs. Frames to have in-build grooved sealing system and shall be site fitted with PVC seal as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with puff. Door leaf shall be 46mm thick fully flush double skin door, with or without vision lite. Door leaf shall be manufactured from minimum 0.8mm (22guage) thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door handle. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf..All doors and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of door and hardware as a complete assembly as mentioned in the door and hardware schedule. Once frame installed should be filled with PUF as recommended by the manufacturer or engineer. Shaft door os size 600mmX1500mm

17

-

-

... More
Flooring and Waterproofing

-

-

-

... More
11.5 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures specification. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

1001.48

-

-

... More
13.52.2 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work

1001.48

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

4463.16

-

-

... More
Providing and laying anti skid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600mm.

368.43

-

-

... More
11.48.2 : Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

368.43

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

14.64

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

5573.28

-

-

... More
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in dadoing over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), fixing with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 6mm thickness, joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

968.4

-

-

... More
Providing and fixing machine cut, mirror/ eggshell polished , Flamed finished granite work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and fixing with chemical adhesive and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.18 mm thick granite stone slab of approved colour.

92.16

-

-

... More
Providing and laying Vitrified step tiles in single piece indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.

231.53

-

-

... More
Extra for using or fixing glazed/ Ceramic/ Vitrified wall tiles with cement based high polymer modified quick-set tile adhesive ( Water based) conforming to IS : 15477, in average 3 mm thickness.

5573.28

-

-

... More
11.55.1 : Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

653.62

-

-

... More
8.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of approved colour and shade. Area of slab over 0.50 sqm

29.85

-

-

... More
8.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work

1653.9

-

-

... More
Grading roof for water proofing treatment with 12mm thick plastering in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and mixing with water proofing material in proportion recommended by the manufacturers

1289.51

-

-

... More
22.23.1 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer in- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm

1693.96

-

-

... More
22.23.2 : Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer in- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.

462.67

-

-

... More
22.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

578.82

-

-

... More
11.3.1 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate

335.66

-

-

... More
Surface Preparation: Existing concrete surface shall be made clean,dry,smooth and free of chemical contaminants.The surface shall be thoroughly cleaned by using hand operated grinders for removing the laitence and exposing the porosity in the concrete surface. Down Take Pipe Packing: The pipes to be fixed should be filled in order to provided a proper bond and the same to be aligned by the respective agency.The annular space around the Rainwater pipe shall be packed using Conbextra GP2 or equivalent, a high strength free flow non shrink grout mixed water in ratio 0.16 The surface shall be suitably prepared using wire brush, primed with Nitobond SBR or equivalent on the core surface fixing leak free form work as per manufacturer's specification. Coving:Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with Nitobond SBR or equivalent at dosage of 2Ltrs per50kg cement as per manufacturer's specification. Pressure Grouting at Leaking points: Water ponding for minimum 48 hours and 50mm height shall be done to observe weak points in the concrete. Providing cementitious based injection grouting at construction joints, leaking spots and honey combs with 40 psi pump using Cebex100@225gms or equivalent mixed to 50kg bag of cement including joints packing using polymer modified mortar. Fixing of nozzles and chipped portions of nozzles shall be reinstated using Renderoc Plug as per manufacturer's specification. Providing and applying a single component pitch free polyurethane based coating using Fosroc Nito proof 600 or equivalent that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane. It is elastomeric,seamless waterproof membrane applied in 2coats to DFT 1.2mm thick having a elongation capacity of over 400%. Termination to bed one on wall extending the coating to min. 300mm height above the finished floor level and sealed inside the groove of 20mm wide x 10mm thick flushed with polymer modified mortar as per vendor recmmendation. Laying 200gsm non woven geo textile membrane over waterproofing coating with overlap sealed using synthetic rubber adhesive before providing screed concrete. The material shall comply to ASTMC836. Elongation (ASTMD412):400%,Specific gravity:1.4g/cc, Solid content:85%, Modulus@100% elongation (ASTMD412):0.62N/mm², Tear resistance (ASTMD624):15N,Water vapour transmission (ASTME96):0.6g/m²/hr.,Water permeability@5bar: Nil, Shore A hardness (ASTM D2240) : 60.

1289.51

-

-

... More
False ceiling works and Expansion Joint

-

-

-

... More
12.52.1 : Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending

1821.71

-

-

... More
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.GI Metal Ceiling Lay in perforated Tegular global white color tiles of size 595x595 mm and 0.5mm thick with 8 mm dip; made of GI sheet having glavanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation

2356.1

-

-

... More
Aluminium Non perforated false ceiling - Providing & Fixing true horizontal level swing down suspended ceiling comprising of approved make Aluminum Clip in Swing Down with double pip self-leveling feature and special tabs to allow swing down of tile to enable plenum access with plain visual consisting of 600X600 mm clip in plain tiles of 0.7mm uniform thickness Aluminum with bevel edge in approved color precoated with primer coat at the rear side with Light Reflectance 60%.Tiles should have fire performance of Class A2-s1.d0 as per N13501.The grade of aluminiumshall mandatorily be AA 3003.The AluminiumTile shall mandatorily be RoHS Compliant (Resistance of Hazardous Substance).Compliant certificate shall be provided on demand.The tile shall maintain uniform Thickness of 0.7mm across all areas of tiles with no deviation. The tile shall have paint thickness of 25microns to enable better scratch resistance.The tile shall have the ability to combine the main light with extra illumination providing 77% light reflectance & enables to achieve light uniformity. The tile shall have g Ceiling Attenuation Class of 44db. It shall withstands upto 150 Scrub cycle using Scrubablity tester as per ASTM D 2486. The tile shall offer superior wash performance without compromising panel finish integrity using a washablity tester as per ASTM D 4828. Installation: To comprise 3000mm long ‘C’ channels spaced at 1200mm centers securely fixed to the structural soffit by support clamp & approved hangers.The last hanger at the end of each C channel should not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm spring tee bars shall be spaced at 600mm centers in a direction perpendicular to the C-channels and shall be secured at every intersection with C channel using a tee bar hanger. Use T bar connector to splice two pieces of spring tee bars. Tiles should be clipped in between two spring tee bars from below. This is a downward installation. All full panels can be removed and reinstalled without movement up into the plenum area. Perimeter trims of approved color secured to walls at 450mm maximum centers. Cut tiles to be secured to the wall angles using a spring clamp. The installation shall be undertaken as per the manufacturer’s installation instructions and as directed by the Engineer-in-Charge

365.74

-

-

... More
12.45.3 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board

332.31

-

-

... More
5.44.2 : Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self – centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge . (Material shall confirm to ASTM 6063).Floor Joint of 150 mm gap.

52

-

-

... More
5.45.2 : Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221-02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).Wall Joint of 150 mm gap.

196.8

-

-

... More
EXPANSION JOINT TREATMENT WORKS – INTERNAL WALL & CEILING:A)Providing, placing and fixing in position 150 mm wide and 100 mm thick PVC board of supreme make or Equivalent of 100 kg/cum density at all expansion joints and separation joints and wherever specified to the required sizes, shapes, etc., complete B)Protecting the expansion joint system with Aluminium sheet in a U shape fashion, extending the same up to 150 mm on both side vertically. (Both Horizontal & Vertical) Thickness of sheet is 2 mm

52

-

-

... More
5.46.2 : Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s preengineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063.Roof Joint of 150 mm gap.

12.5

-

-

... More
Finishes

-

-

-

... More
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

3135.57

-

-

... More
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer

24300.72

-

-

... More
Wall painting with acrylic emulsion paint(low VOC paint as per Griha norms V-2015) of approved brand and manufacture to give an even shade. Two or more coats on new work

18728.44

-

-

... More
5.23 : Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).

6436.02

-

-

... More
5.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.

1238.43

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc.Excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size).

36.84

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

22943.26

-

-

... More
13.5.1 : 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 ( 1 Cement : 4 coarse sand)

394.22

-

-

... More
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)

1888.8

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

21299.02

-

-

... More
Finishing walls with Acrylic Smooth exterior paint (low VOC paint as per Griha norms V-2015) of required shade. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

8125.39

-

-

... More
Finishing walls with textured exterior paint (low VOC paint as per Griha norms V-2015) of required shade.New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

902.83

-

-

... More
13.33.1 : Pointing on stone work with cement mortar 1:3 ( 1 cement : 3 fine sand):Flush/ Ruled pointing

197.78

-

-

... More
60.6 : PVC WEEP HOLES- Providing weep holes using 75mm dia. PVC pipes working pressure 4kg /sq.cm including cost of materials, conveyance, labour charges etc. complete.

160.46

-

-

... More
12.63 : Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittnce tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strictly as per manufacture's specifications and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the performance of SRI and also the durability of coating, all complete as per direction of Engineer - in- charge.

952.87

-

-

... More
Finishing and Roofing

-

-

-

... More
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

983.75

-

-

... More
12.51.1 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)

102.12

-

-

... More
12.51.6 : Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Gutter (600 mm over all girth)

207.8

-

-

... More
Poly carbonate sheet roofing -Supply and installation of 2mm thick Poly-carbonate sheet roofing of approved make, embossed clear with UV protection coating/treatment and weight not less than 2400gms/ sqm. It shall be fire retardant and confirming to IS 14443. the rate shall include aluminium leak proofing and fixing management system with EPDM rubber gaskets, silicone sealant etc. complete as required and as per the direction of engineer in charge

106.05

-

-

... More
External Works

-

-

-

... More
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

18.61

-

-

... More
15.5 : Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge.

3.62

-

-

... More
15.13.1 : Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metes and below

2

-

-

... More
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

60.96

-

-

... More
14.2.2 : Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for hold fasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm, with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground within 50 meters lead:Window chowkhats

1

-

-

... More
15.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved

20

-

-

... More
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete

41.7

-

-

... More
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar

30

-

-

... More
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

9.75

-

-

... More
2.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girth

3

-

-

... More
2.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girth

2

-

-

... More
2.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth

2

-

-

... More
2.33.4 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Above 240 cm girth

1

-

-

... More
2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared

500

-

-

... More
19.35.1 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.450 mm dia RCC pipes.

18

-

-

... More
19.35.2 : Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete.600 mm dia RCC pipes.

25

-

-

... More
16.78.1 : Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30

635.25

-

-

... More
16.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.

785.24

-

-

... More
16.91.2 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweepig extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

1755.77

-

-

... More
16.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)

10.89

-

-

... More
22.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

119.2

-

-

... More
15.43.2 : Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road

1.45

-

-

... More
14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)

5.2

-

-

... More
Relaying the excavated GSB in Specified Thickness in all lift and leads spreading in uniform layers of specified thickness and compacting with plate vibrator to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.

12.92

-

-

... More
Site Clearence

-

-

-

... More
Clearing and grubbing land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and preservation of top organic soil not exceeding 200 mm in thickness In area of thorny jungle - By Mechanical Means

0.4

-

-

... More
2.5.1.B : Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately. Granular courses - By Manual Means

21.96

-

-

... More
11.9 : Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year

24

-

-

... More
Subhead 2 - PUBLIC HEALTH ENGINEERING SANITARY FIXTURES, BATH FITTINGS AND ACCESSORIES

-

-

-

... More
Providing and fixing White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF (Adjusting up to 2/4 LPF) Dual Cistern, Overall size 660 x 375 x 760mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion / rawl sleeves,gasket etc. complete, and fixing to wall, as per manufacturer's instruction and to the approval of Engineer-in-charge. The Float Valve for Cistern shall be capable of withstand 5.0 Bar. Working Pressure.

66

-

-

... More
Providing and fixing sanitary fixtures for handicapped toilet including one number White Vitreous China Extended Wall Mounted EWC, Complete Set with 3/6 LPF (Adjusting up to 2/4 LPF) Dual Cistern, overall size 660 x 375 x 760mm. or as per approved model and shape, including Cistern Fittings, Soft Close Seat Cover, bolts, nuts, washers, expansion / rawl sleeves, gasket etc.complete, wash basin, one pair mounting brackets, one number elbow operated pillar cock 3.8 LPM @ 3 Bar and all other related fittings like waste coupling one number hinged rail 76 cm & 4 nos. of grab rails 60cm etc., designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge.

1

-

-

... More
17.1.1 : Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

5

-

-

... More
Providing and fixing White Virtuous China Urinal, of approved shape and size,with Integral P-Trap and with Integrated Electronic Flushing System with Passive and Extra Sensitive Infra-Red Sensor (Battery/AC Operated, as per final requirement), overall size: 610 x 390 x 370mm, with a Total Flushing Rate of 0.75 LPF, having pre & post flushing with water, (250 ml & 500 ml respectively),and with water inlet from back side including fixing at wall with suitable Brackets, all as per manufacturer's instruction and direction of Engineer-in-charge

8

-

-

... More
8.10.2 : Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade

5

-

-

... More
Providing and fixing White Vitreous China Counter Top / Bottom Wash Basin, 400 x 550 mm or equal, compatible for a washing rate of 6 LPM or less, including 32mm. CP Waste Coupling, C.P. Brass Chain with rubber plug, and fixing to counter with suitable fixtures, all as per manufacturer's instruction and the direction of Engineer-in-charge.

42

-

-

... More
Providing and fixing White Vitreous China Wall Hung Wash basin, 550 x 400 mm or equal, including 32mm. CP Waste Coupling, C.P. Brass Chain with rubber plug, and fixing to wall with suitable fixtures, all as per manufacturer's instruction and the direction of Engineer-in-charge.

18

-

-

... More
Providing and fixing 15mm. CP Pillar Tap, Self Closing Type with Pre Set time 5 to 6 Sec, with a controlled flow rate of 2.5 LPM at 3 Bar.(overall dimensions:110 x 120 /150mm. or equal ), complete with all necessary accessories for Domestic Wash Basins, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

60

-

-

... More
17.25.6 : Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:Surgeon type wash basin of 660x460 mm

10

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action Pillar Tap with extended lever handle, flow rate of 3.8 LPM at 3 Bar, complete with all necessary accessories for Wash Basins in Doctors / Treatment Rooms, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

10

-

-

... More
Providing and fixing of Black colour Poly Propylene Laboratory Sink, Dimensions: external 558 x 355 x 240mm, Net weight: 2.7 kg, Temperature range: 0-80°C, 1/2” BSP Waste connection, Net weight: 0.2 kg Dimensions: Ø73, 1½” BSP with PTMT/PP waste coupling, adjustable screw on nut. , including cutting and making good the walls wherever required: Polypropylene Laboratory Sink without drain board

23

-

-

... More
17.10.1.3 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 200 mm

2

-

-

... More
17.10.2.1 : Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm

2

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action, Wall Mounted type, Clinical Sink Tap with extended lever handle, flow rate of 3.8 LPM @ 3 Bar, complete with Wall Flange and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

12

-

-

... More
Providing and fixing CP Surgical Purpose Elbow Action, Wall Mounted type, Clinical Sink Mixer with extended lever handle, flow rate of 3.8 LPM @ 3 Bar, complete with Wall Flanges and all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge

15

-

-

... More
Providing and fixing CP Shower Set, for Cold Water only, low flow rate of 6 LPM or less, Commercial Range, complete with Concealed Valve & Exposed Control Unit, Head Shower, Shower Arm, etc.,including all necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

40

-

-

... More
Providing and fixing CP Long Body Tap, both Cold & Hot Water Supply, with a controlled flow rate of 6 LPM @ 3 Bar, 15mm. nominal bore, 185mm. long with wall flanges and all other necessary accessories,all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

115

-

-

... More
Providing and fixing Health Faucet with a controlled flow rate of 3.8 LPM @ 3Bar, 15mm. CP Braided Hose, Hook and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.

72

-

-

... More
18.53.1 : Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

210

-

-

... More
18.21.2.1 : Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore

143

-

-

... More
50.17.1.3 : Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

40

-

-

... More
17.72 : Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms

44

-

-

... More
50.17.1.1 : Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

18

-

-

... More
17.34.1 : Providing and fixing toilet paper holder:C.P. brass

2

-

-

... More
Providing and Fixing ABS Body P-Trap with threaded union connections, flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge. For Wash Basin, 32mm, Size.

60

-

-

... More
Providing and Fixing ABS Body P-Trap with threaded union connections, flanges and all other necessary accessories, all as per manufacturer's instructions and to the approval of the Engineer-in-charge.For Clinical Sinks and Scrub, 40mm, Size

27

-

-

... More
Providing and fixing at site in position Grab Bar up to 600mm complete.

71

-

-

... More
Providing and fixing of C. P. Robe Hook, 60mm. Dia. x 45mm. High.

72

-

-

... More
17.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

22

-

-

... More
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

33

-

-

... More
Providing and fixing cooler (hot, cold and normal water) with inbuild RO filter including cost and conveyance of all materials labour charges etc. complete, including necessary wall cutting / chasing and making good as required etc. complete, testing and commissioning to the satisfaction of Engineer in Charge as per direction of Engineer-In charge at all levels

1

-

-

... More
Providing and fixing of Slop Hopper with Pressing valve 304G Stainless Steel, Conical flushing bowl with continues flushing rim having whirl effect, P / S trap for drainage, Health faucet Dimension : 24”L x 24”W x 35”H"

2

-

-

... More
INTERNAL DRAINAGE

-

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).160mm OD

6

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592) including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y,couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners (8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).110mm OD

695

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type B (IS:13592)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y,couplings, adapters, rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Soil & Waste pipes -Internal).75mm OD

945

-

-

... More
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall

232

-

-

... More
50.18.9.15.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 40 mm dia 6 Kgf/cm2 - External work - Exposed on wall

75

-

-

... More
50.18.9.14.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall

106

-

-

... More
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2

174

-

-

... More
50.18.8.5.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2

30

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of Type A (IS:13592)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends, Y,couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site(For Vent pipes -Internal).75mm OD

15

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position uPVC pipe (SWR) of 4kg/cm2 (IS:4985)including injection moulded fittings with bosses where required eg 90 Degree, 45 Degree bends,Y, couplings, adapters,rodding eye & clamping with Universal clamps, Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete; and jointing with approved adhesive by manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site (For Vent pipes -Internal).63mm OD

145

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately. Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details- For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 160mm OD

6

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, roddingeye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping). Core Cutting in RCC Structure shall measured separately.Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails (2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.110mm OD

504

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type B(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping).Core Cutting in RCC Structure shall measured separately.Clamping details - For Vertical Shafts .G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete.75mm OD

420

-

-

... More
"Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 '' STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners(10mm),Threaded Rod(10mm), nuts, washers etc complete.110mm OD

227

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe (SWR) of Type A(IS:13592) including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent). Clamping details - For Vertical Shafts G.I."U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated, Clamping details - For Suspended lines G.I."U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps,Anchor fastners(10mm), Threaded Rod(10mm), nuts, washers etc complete. 75mm OD

42

-

-

... More
Supplying, Installing, Testing & Commissioning at site in position Ring uPVC pipe of 4kg/cm2 (IS:4985))including SWR jointing with Rubber Ring Seal (IS 5382) PVC Moulded (IS 14735 )fittings with bosses where required eg.Door tees, Door bends, 'Y', bends, clamps, couplings, adapters, rodding eye and cowls with sealing grooves and clamping with Position, including cutting and making good the walls and floors as required at site (For Vertical & Horizontal Shaft piping for rainwater/Vent).Clamping details - For Vertical Shafts G.I. "U" bolts (8 mm thick) on G.I. slotted rails (1.6 / 2.5 mm thick) , Rail Leg 2 1/2 ''STD Powder Coated Clamping details - For Suspended lines G.I. "U" bolts (8 mm thick) on Heavy Duty G.I.slotted rails(2.5 mm thick) or Clamping with Universal clamps, Anchor fastners (10mm), Threaded Rod (10mm), nuts, washers etc complete. 63 mm OD (4kg/cm2)

227

-

-

... More
Deep Seal uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position Deep Seal (7”) uPVC Fabricated Multi Floor Trap, with suitable supporting on GI slotted rails(1.6mmthick) full threaded rod, Anchor fasteners etc. complete in all respects - 50/75 mm dia inlet/outlet (In Ceiling)

134

-

-

... More
uPVC fabricated Multi floor trap - Providing, Fixing, testing and commissioning at site in position uPVC Fabricated Multi Floor Trap, with thrust block support including complete cost o cutting chases and making good the walls in all respects - 50/75 mm dia inlet/outlet (In Sunken)

34

-

-

... More
Supplying, installing, testing & commissioning at site in position 110mm dia deep seal PVC P Trap with boss tee and access cap including all necessary fittings and supports complete.

6

-

-

... More
Providing and Fixing C.P. brass or stainless steel(SS-304) Square Flat cut single piece Gratings size 125x125 mm. Gratings for 110mm. Floor Traps.

168

-

-

... More
Heavyduty stainless steel cover for Concealed Floor Trap for Urinal - Providing and Fixing 125x125mm dia Heavyduty stainless steel cover for Concealed Floor Trap ISI 304 Cover, for Urinal.

6

-

-

... More
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 110mm

38

-

-

... More
Heavy duty stainless steel cleanout cover - Providing and Fixing Heavy Duty Stainless Steel A ISI 304 Clean out Cover, sealed, threaded covers, including suitable keys for opening, if required. - For 75mm

70

-

-

... More
17.35.1.3 : Providing and fixing soil, waste and vent pipes:100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

44

-

-

... More
17.38.1.3 : Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm diaHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

4

-

-

... More
17.39.1.3 : Providing and fixing plain bend of required degree.100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

8

-

-

... More
17.42.1.3 : Providing and fixing double equal plain junction of required degree.100x100x100x100 mmHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905

1

-

-

... More
17.44.1.3 : Providing and fixing single equal plain junction of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

3

-

-

... More
17.49.1.3 : Providing and fixing double equal plain invert branch of required degree:100x100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

1

-

-

... More
17.50.1.3 : Providing and fixing single equal plain invert branch of required degree:100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

3

-

-

... More
17.56.1.3 : Providing and fixing terminal guard:100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

1

-

-

... More
17.60.1.3 : Providing and fixing trap of self cleansing design with screwed down or hinged grating without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outletHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905

6

-

-

... More
17.57A.1.1 : Providing and fixing shielded coupling for Hubless centrifugally cast iron pipeSS 304 grade coupling with EPDM rubber gasket

56

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Dome Type with Cast Iron body, Aluminium Ring, Aluminium Dome, S.S. Screws etc. complete with Gratings, suitable for 160mm. of down pipes. 150mm dia. for 160mm. PVC Down Pipe

5

-

-

... More
"Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Dome Type with Cast Iron body, Aluminium Ring, Aluminium Dome, S.S. Screws etc. complete with Gratings, suitable for 110mm. of down pipes. 100mm dia. for 110mm. PVC Down Pipe

15

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Side Wall Parapet Type in Cast Iron body,Aluminium Gratings, S.S. Screws etc. complete with Gratings, all as per Technical Specifications. 100mm dia. for 110mm. PVC Down Pipe

3

-

-

... More
Supply, fix at site in position, Rain Khurra (Rain Water Outlet) Side Wall Parapet Type in Cast Iron body,Aluminium Gratings, S.S. Screws etc. complete with Gratings, all as per Technical Specifications. 150mm dia. for 160mm. PVC Down Pipe

3

-

-

... More
WATER SUPPLY

-

-

-

... More
18.8.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes

52

-

-

... More
18.8.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

960

-

-

... More
18.8.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes

15

-

-

... More
18.7.1 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall15 mm nominal outer dia pipes

220

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

1100

-

-

... More
18.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipes

285

-

-

... More
18.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipes

225

-

-

... More
18.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipes

165

-

-

... More
18.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipes

20

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work -Exposed on wall - Ceiling and Shaft-20 mm nominal outer dia. Pipes.

120

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing, Anchor fastners (8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall - Ceiling and Shaft-25 mm nominal outer dia. Pipes.

120

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work -Exposed on wall - Ceiling and Shaft-32 mm nominal outer dia. Pipes.

220

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft-40 mm nominal outer dia. Pipes.

60

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 50 mm nominal outer dia. Pipes.

180

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes

200

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 80 mm nominal outer dia. Pipes.

30

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, fixing the pipe with Universal clamps/U bolt at 1.00 m spacing,Anchor fastners(8mm), Threaded Rod(8mm), nuts, washers etc complete. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 100 mm nominal outer dia. Pipes.

20

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work -Exposed on wall - Ceiling and Shaft 65 mm nominal outer dia. Pipes.

70

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step uPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall - Ceiling and Shaft 80 mm nominal outer dia. Pipes.

70

-

-

... More
18.18.1 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:15 mm nominal bore

5

-

-

... More
18.18.2 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

119

-

-

... More
18.18.3 : Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore

25

-

-

... More
18.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

22

-

-

... More
18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

12

-

-

... More
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

12

-

-

... More
18.19.2.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):32 mm nominal boreHorizontal

2

-

-

... More
18.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontal

2

-

-

... More
18.19.5.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):65 mm nominal boreHorizontal

3

-

-

... More
18.19.6.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):80 mm nominal boreHorizontal

3

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories. 15mm. (1/2")

36

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories. 20mm. (3/4")

10

-

-

... More
Supply, fix at site in position, test and commission Gun Metal Globe Valves, PN:20, Screwed Female ends, complete with all necessary accessories. 25mm. (1")

6

-

-

... More
Brass Automatic Air Release Valves - Providing, Fixing, testing and commissioning at site in positions Brass Automatic Air Release Valves, of approved quality and make on the top of the vertical water supply pipes as per specification and drawing - 3/4"(20mm) dia

20

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN 10) of approved make with PP float & nipple with brass threaded in-sert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 40mm dia (1 ½”)

1

-

-

... More
Supplying, Installing & Testing at site in position Brass Float valve (PN10) of approved make with PP float & nipple with brass threaded in-sert, brass back nuts, piston and bolts etc complete in all respect to the satisfaction of Project Manager. 50mm dia (2”)

1

-

-

... More
SS ball valve 50mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 2”(50mm) dia

1

-

-

... More
SS ball valve 40mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1½”(40mm) dia

1

-

-

... More
SS ball valve 32mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1¼”(32mm) dia

2

-

-

... More
SS ball valve 25mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - 1” (25mm) dia

8

-

-

... More
SS ball valve 20mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - ¾” (20mm) dia

26

-

-

... More
SS ball valve 15mm dia - Providing, Fixing at site in position full way lever operated SS ball valve (screwed end)of SS body (316) of approved make with necessary MTA fittings in position as per drawings. - ½” (15mm) dia

4

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect. 50 mm dia

1

-

-

... More
Supplying, Installing & Testing at site in position CI Wafer swing type check Valve (PN-16) type with necessary fittings complete in all respect.65 mm dia

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum. Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection. Water meter 40mm

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10 microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum. Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection.ater meter 50mm"

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10 microsiemens/cm. It can handle Temperature up-to 100º Celsius &performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum. Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10 meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection. Water meter 65mm

1

-

-

... More
Supply, installation, testing, and commissioning of ELECTROMAGNETIC FLOW METER, Digital Flowmeter with Sensor connected in Water Line and Remote display Data Transmitter separated by means of wired output. EMF shall be suitable for Polluted/ Dirty water having solid sediments or any Conductive Fluids with more than 10microsiemens/cm. It can handle Temperature up-to 100º Celsius & performs only in full bore conditions. Water Sensor is Made of Epoxy Coated Metal Body (Mild Steel) in fully welded construction with ANSI B 16.5 150 flanged ends and with PTFE Liners. The Flow Tube which is made of SS304 Material and Electrodes are of SS316 and meter enclosure is of Cast Aluminum. Remote Display Flow Transmitter Unit contains the illuminated display and can be separated up-to 10 meter distance. It has front panel calibration, LCD display and RS232 Interface. Flow rate, Totalizer and damp functions and pulse output available & compactable for BMS. PN-10, IP-68 Protection. Water meter 80mm

1

-

-

... More
CI Y Strainer 2” (50mm) dia - Supply, Installation, Testing and Commissioning of CI Y-type strainer with drain plug, SS screen 304 complete in all respects.

2

-

-

... More
CI Y Strainer 2 ½” (65mm) dia -Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
CI Y Strainer 3” (80mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
CI Y Strainer 4” (100mm) dia - Supply,Installation,Testing and Commissioning of CI Y-type stainer with drain plug, SS screen 304 complete in all respects

1

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 80 mm. dia. (3") pipe.

30

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 65 mm. dia. (2 1/2") pipe.

165

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 50 mm. dia. (2") pipe

200

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 40 mm. dia. (1 1/2") pipe..

120

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 32 mm. dia. (1 1/4") pipe.

180

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 25 mm. dia. (1") pipe.

132

-

-

... More
Terrace / Roof shall be with 19mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating or Self Adhesive Glass Cloth Covering all from Approved Manufactures and to the approval of Engineer - in- charge / Consultant. For 20 mm. dia. (3/4") pipe.

180

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 40mm. (1 1/2") pipe.

50

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 32mm. (1 1/4") pipe.

80

-

-

... More
"Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 25mm. (1") pipe.

120

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 20mm. (3/4") pipe.

300

-

-

... More
Exposed Pipe Work in Celling Void & at Terrace for Hot Water Services and Hot Water Return Pipework at Terrace shall be with 9mm. thick flexible closed cell elastomeric thermal insulation and additional protection with Poly Shield Coating all from Approved Manufactures, all as per Technical Specifications and to the approval of Engineer - in- charge. (For Hot water Piping)For 15mm. (1/2") pipe.

220

-

-

... More
EXTERNAL SEWERAGE AND STORM WATER DRAIN

-

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete (excluding excavation)200mm OD.

15

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients,PVC pipe of IS 4985(6kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete (excluding excavation) 160mm OD.

480

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients,PVC pipe of IS 4985(6kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS:1742-1983 (Code of practice for building drainage) complete (excluding excavation)110mm OD.

95

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(6kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation)75mm OD.

30

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients,PVC pipe of IS 4985(4kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation)200mm OD.

20

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipeline as per specification, testing the pipeline after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation).160mm OD

120

-

-

... More
Supplying, Installing & Testing of pipes and conveying to position; and jointing to true lines and gradients, PVC pipe of IS 4985(4kg/cm2), jointing the pipe line as per specification, testing the pipe line after installation including Supplying, installing specials like bends, couplers, sockets, connections etc. as per provisions of IS: 1742-1983 (Code of practice for building drainage) complete (excluding excavation).110mm OD

40

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 20 mm nominal outer dia Pipes

15

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 25 mm nominal outer dia Pipes

20

-

-

... More
"Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 32 mm nominal outer dia Pipes

10

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation) 40 mm nominal outer dia Pipes

5

-

-

... More
Providing and fixing uPVC Pipes, Sch. 40 (ASTM D 1785) and with Sch. 40 (ASTM D 2466) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation)50 mm nominal outer dia Pipes

10

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, this includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (Including excavation)65 mm nominal outer dia Pipes.

20

-

-

... More
Providing and fixing uPVC Pipes, Sch. 80 (ASTM D 1785) and with Sch. 80 (ASTM D 2467) Fittings, This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work (Including excavation) 80 mm nominal outer dia Pipes.

20

-

-

... More
Supply,installation, testing and commissioning of stainless steel Bar Screen (opening 15mm) suitable for screen mesh of size 500mmx500mm removable type Screen Member 10mm S.S. Grade 316S Rods in Vertical Pattern

6

-

-

... More
Providing and fixing square-mouth PVC gully trap complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With Sewer bricks conforming to IS: 4885

20

-

-

... More
19.16 : Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design

120

-

-

... More
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia

770

-

-

... More
18.41.1A : Providing and filling sand of grading zone V or coarser grade, all - round the G.I. pipes in external workSub analysis item for sand filling component

55

-

-

... More
4.1.10 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)

55

-

-

... More
CIVIL WORK FOR RCC MANHOLE AND PUMPING PIT

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

262.61

-

-

... More
2.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

228.31

-

-

... More
2.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil

101.44

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

11.88

-

-

... More
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size

67.65

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

8797.51

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

3.72

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

528.2

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

6.96

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

528.2

-

-

... More
10.25.1 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete

2248.9

-

-

... More
Supplying, Installation, Testing and Commissioning of the Ductile Iron Circular Manhole cover with Frame (Double seal with EPDM Gasket and SS Bolting arrangement lifting key holes & load tested as per IS:1726 & BS EN:124. 600mm Dia. (Medium duty) (Minimum weight 68Kg).

5

-

-

... More
Supplying, Installation, Testing and Commissioning of the Ductile Iron Rectangular Manhole cover with Frame (Double seal with EPDM Gasket and SS Bolting arrangement lifting key holes & load tested as per IS:1726 & BS EN:124. 600x 900. (Heavy duty) (Minimum weight 135Kg).

6

-

-

... More
Supplying, Installation, Testing and Commissioning of the Ductile Iron Circular Manhole cover with Frame (Double seal with EPDM Gasket and SS Bolting arrangement lifting key holes & load tested as per IS:1726 & BS EN:124. 600mm Dia. (Heavy duty) (Minimum weight 75Kg).

26

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - For 160mm dia. pipe

4

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 110mm dia pipe

280

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 75mm dia pipe

38

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 63mm dia pipepe

62

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required, complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 50mm dia pipe

120

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound(Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 40mm dia. pipe

10

-

-

... More
Making holes in RCC beams, slabs floors etc, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M 20, including nominal reinforcement wherever required,complete.The quoted rate shall also include water proofing compound (Conbextra GP-2 / GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 100-200 mm thick - 32mm dia pipe

89

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 150mm (6")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -150mm(6") uPVC Astm Sch 80 Puddle flange

2

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 100mm (4")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 100mm(4") uPVC Astm Sch 80 Puddle flange

6

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 80mm (3")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 80mm(3") uPVC Astm Sch 80 Puddle flange

5

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 65mm (2½") uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -65mm (2½") uPVC Astm Sch 80 Puddle flange

6

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 50mm (2")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 50mm(2") uPVC Astm Sch 80 Puddle flange

12

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 40mm (1½")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. -40mm (1½")uPVC Astm Sch 80 Puddle flange

2

-

-

... More
Supplying, Installing & Testing at site in position Fabricated 32mm (1¼")uPVC Astm Sch 80 Puddle flange in the overhead water tanks as per the drawings and the requirement of the Project Manager. - 32mm 1¼"uPVC Astm Sch 80 Puddle flange

4

-

-

... More
WATER TREATMENT PLANT

-

-

-

... More
Supply, Installation, testing and commission Water Pre-Treatment Plant Capacity: 10M3 /Hr, for continuous operation of 10 Hr, complete with High Pressure Sand Filter, Activated Carbon Filter,with Multiport valves, Chemical Dosing etc as per final requirement, connected Pipe Work etc, all as per Technical Specifications

1

-

-

... More
SEWAGE TREATMENT PLANT

-

-

-

... More
Supply, Installation, testing and commission Sewage-Treatment Plant Capacity: 100KLD, MBR Type for continuous operation complete with Ultra Filter,with Multiport valves, Chemical Dosing etc as per final requirement, connected Pipe Work etc, all as per Technical Specifications.(Excluding Civil Works)

1

-

-

... More
VALVES (E AND M)

-

-

-

... More
16.11.1.2 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) of 150 mm dia

1

-

-

... More
16.11.1.4 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 100 mm dia

2

-

-

... More
16.11.1.5 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 80 mm dia

4

-

-

... More
16.11.1.6 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedButterfly Valve ( Manual) 65 mm dia

12

-

-

... More
PLUMBING PUMPS AND HEAT PUMPS

-

-

-

... More
Supply, Installation, Testing and Commissioning 2 nos, Vertical multistage Pump Set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 3.5lps @ 45mtr head, Head range 30 to 60 mtrs, ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection with Wall mounting Microprocessor based common control Panel to operate the pump set as ( 1Working + 1Standby ) Star Delta, having features of automatic pump change over in every Start/Stop, Dry run,Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function with sufficient length cable, Digital display, Pressure gauge - 2nos, Float Switches, Auto/Manuel Operation.

1

-

-

... More
Supply, Installation, Testing and Commissioning 2 nos, Vertical multistage Pump Set, having SS Impeller and Shafts, CI/SS Casing, Mechanical Seal Each pumps should be capable to deliver 3.05lps @ 55mtr head, Head range 40 to 70 mtrs, ''F'' class Insulation, IE3 Rated Electric Motors, IP 55 Protection with Wall mounting Microprocessor based common control Panel to operate the pump set as ( 1Working + 1Standby ) Star Delta, having features of automatic pump change over in every Start/Stop, Dry run, Overload, Phase Reversal Protections etc. level controller for Auto Start/ Stop Function with sufficient length cable, Digital display, Pressure gauge - 2nos, Float Switches, Auto/Manuel Operation.

1

-

-

... More
Supplying, Installing, Testing & Commissioning of SEWAGE & WASTE WATER TRANSFER CUM CUTTER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Pumps with High Efficiency Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base,Stainless Steel (Grade:304) Lifting Chains etc, complete. Required upto 35mm size solid handling. Impeller Material: Cast Iron FG 260 Shaft Material: S.S AISI 410 Capacity: 5.25LPS @ 22Mtr. Head, Head range 14 to 30 mtr, 3Ph, Complete Set."

1

-

-

... More
Supplying, Installing, Testing & Commissioning of SEWAGE & WASTE WATER TRANSFER CUM CUTTER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Pumps with High Efficiency Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304) Lifting Chains etc, complete. Required upto 35mm size solid handling. Impeller Material: Cast Iron FG 260 Shaft Material: S.S AISI 410 Capacity: 5.60LPS @ 22Mtr. Head, Head range 14 to 30 mtr, 3Ph, Complete Set.

1

-

-

... More
Supplying, Installing, Testing & Commissioning of SEWAGE & WASTE WATER TRANSFER PUMPS AND ACCESSORIES Shall be Heavy Duty, Durable & Long Lasting Pumps with High Efficiency Electrical Motors, One Working + Cyclically Stand by with Microprocessor Based Control Panel, for Auto and Cyclic Operation, Float Switches, for Auto Start and Stop of Pumps, Feet / Base, Stainless Steel (Grade:304)Lifting Chains etc, complete. Required upto 35mm size solid handling. Impeller Material: Cast Iron FG 260 Shaft Material: S.S AISI 410 Capacity: 2.80LPS @ 22Mtr. Head, Head range 14 to 30 mtr, 3Ph, Complete Set."

1

-

-

... More
FILTER FEED PUMP SET. Supply, Testing and Commission Filter Feed Pump Set, Submersible Type for Pumping Raw Water to Water Treatment Plant, 2 Pump System with One Working + 1 One Cyclically Stand by Pumps, each Pump of Capacity: 10M³/Hr. @ 16Mtr. Head, Head range 10 to 20 mtr,having CI Casing, SS Shafts, CF8 Impeller with 3Ph, complete with Microprocessor Based Control Panel,for Auto and Cyclic Operation, with all Protection (Digital display, Low &high voltage protection, dry run,phase reversal, pump over load, etc.), Level Sensors / Float Switches in Treated Water & Raw Water Tanks and Control Cabling / Wiring between Level Sensors / Float Switches and Control Panel, Delivery Manifold, Isolating Valves, Non Return valves, Pressure Gauge, Fittings, Stainless Steel (Grade:304)Lifting Chains, Accessories etc. all as per Technical Specifications. The Control Panel shall be capable operating the pumps (starts and stops) by sensing the level difference in water in the Treated Water Tank. Also; capable of ‘not starting or stopping the running pumps', when the water in the underground Raw Water Tank goes below the pre-set minimum level. The Pumps to be installed in the Underground Raw Water Tank and Common Control Panel in the Pump Room, in Basement Floor,approx. 50 Mtr. away from Raw Water Tank. The Underground Power Cabling between Pumps and Control Panel and Control Cabling between Control Panel & Level Sensor / Float Switch, in the Underground Raw Water Tank, shall be measured as a part of Electrical Work. The Quoted Price for the Pump Set shall be inclusive of all above requirement, necessary Level Sensors / Float Switches, Power Cabling, Control Cabling etc, except what measured as a part of Electrical Work, as detailed above

1

-

-

... More
"Providing, Fixing, Testing and Commission Submersible Type Dewatering Pump Set, complete set with 1 working Submersible non- clog pump, Solids handling: 10mm, and with Common Control Panel for auto and cyclic operation. Capacity 3.5lps at 13.5Mtrs. head each, Head range 5 to 17 mtr, Three Phase, with float switches/level sensors etc. necessary control valves, fittings and accessories, for discharging rain water from collection pits in basement floor, to lower strata. The price shall inclusive of all connected electrical work as detailed in the technical specification. Impeller - Cast Iron FG 260 Cast Iron - S.S AISI 410"

1

-

-

... More
Supply, installation, testing & commissioning of Solar assisted Heat pump, insulated pressurised SS storage tank, hot water expansion vessel, insulated piping between the system, valves & accessories required to complete the system in position with the following specification. 5000 LPD, consisting of Solar Hot Water Panels of Aggregate Capacity: 2500 LPD (50% of the total requirement), 58 Deg C required Insulated Hot Water Storage Tank suitable for 6 bar pressure SS 316 - 3000 Litre, COP of Heat pump 4, Including of the Circulation Pumps between heat pump/Panels and storage tank, control panel. Plumbing work Between storage tank and heat pump CPVC Pipe with suitable CPVC Fittings.Suitable Brass Fittings like NRV, Y Strainer, Air Vent, MTA, FTA, Flow Switches, Pipeline Insulation Electrical Work From Pump panel to heat pump 6 Square MM 4 core cable, 1.5 Square MM 3 core cable, 2.5 Square MM cable,Communication cable, 3 x 9Amps 3MP Contactors Coil Operated, PVC conduits for cables with suitable fittings etc., complete."

1

-

-

... More
Supplying, Installing, Testing & Commissioning at site hot water recirculation pump with suitable pressure switch, dry run protection & The Enclosure should be of IP 55 standards. The Panel should have BMS compatible thro RS 485 Communication(Modbus). Type : Thermostatic Controlled. Horizontal,multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The shaft,impellers and chambers are made of stainless steel. The inlet and discharge parts are made of cast iron.It’s supporting up to 95 degree Celsius temperature, digital control panel with Time and Temperature settings facility. Flow for each pump in LPS : 5 Head in mtr : 7 MOC : SS 304 Impeller Total no of pump: 1 SET ( 1Working + 1Standby )"

1

-

-

... More
SUBHEAD 3 - ELECTRICAL WORKS HT WORKS

-

-

-

... More
HT PANEL Supply, installation, testing and commissioning of dust and vermin proof floor mounted free standing cubicle type, 11kV, extensible panel board made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors interlocked with the earth switch, comprising of one number of 630A VCB as incomer and two numbers of 630A VCB as outgoings as per the specification details below. Each VCB panel also include POWER PACK/UPS of required capacity for auxiliary power supply unit with all accessories required for complete installation as required and providing all connection and interconnections as required and as instructed by engineer in charge. Incomer 1no:-11kV 630A, 3phase 50Hz, 500MVA, breaking capacity motorized vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type including providing station class polymeric type surge arrestor (10kA) with necessary switch for protection, trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection metering. Draw out type resin cast P.T with inbuilt fuses of ratio 11kV/110V, CL : 1, must be provided. Bus bar compartment shall have suitable capacity non-hygroscopic and high dielectric strength SMC/FRP busbar supports with electrolytic Aluminium busbars covered with suitable sleeves. Metering compartment for mounting digital meter and numerical relays for feeder protection, shunt/series trip coil, RYB indication lamps, cable entry boxes, including all interconnections, providing fire/heat resistant coatings for busbar CB truck enclosures and powder coating complete panel as per IS-2516 IS 3427 with latest amendments complete as required. It shall also be provided with Instantaneous IDMT relay 2 O/C + 1 E/F relay CDAG-51 or Equivalent with high Set, Master Trip Relay. CT Rating : 100/1/1: Core 1: CL-0.5, Core 2: 5P10 Out goings : 2 Nos:-11kV 630A, 3phase 50Hz, 500MVA, breaking capacity motorised vacuum circuit breaker dust and vermin proof totally enclosed in sheet steel housing, fully inter locked, horizontal draw out and horizontal isolation, indoor truck type with trip free spring closing mechanism with mechanical ON/OFF indicators, earthing terminals automatic safety shutters,8W annunciator, complete with auxiliary contacts, resin cast CTs of suitable ratio and accuracy class for protection.

1

-

-

... More
Supply,fabrication, erection, testing & commissioning of 11 KV DP structure using required size of ISMB for poles and required size cross channel with ISMC for supporting structure for 11kV components, 11 KV pin, disc and stay insulators, supports, jumpers '/interconnecting conductors with 0'SWG Cu, 25x3mm braided copper earthing for non current moving part like handle of AB switch etc. The item includes erection of DP structure on suitable concrete foundation and painting with one coat of metal primer after fabrication and two coats of aluminium enamel paint after erection complete and consists of the following. The cost of the civil foundation shall be measured along with civil items. The design of the foundation shall be got approved from Engineer-in-charge before execution. 11KV,630 A single brake,TP, gang operated AB switch with operating handle & locking mechanism - 1 set 11 KV Lighting Arrestors - 1 set 11 KV D rop out fuses - 1 set The consumers DP structure shall be braced with state electricity board DP structure if required & interconnection shall be done with 0 SWG Cu wire. The DP structure shall be with all necessary accessories for connecting 11kV cable as per particular specification & drawing. The 11kV DP structure shall be done as per the requirement of statutory authority.

1

-

-

... More
HT METERING KIOSK: Supply, installation, testing and commissioning of HT metering Panel with Earth switch, Bidirectional TOD meter (with RS485 communication facility), CTs(0.2S) and PT(0.2) HT fuse, test terminal block, control fuses, etc. The Panel shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 54 with canopy, weather proof, undergone seven tank process with powder coated finish. The Panel should have seal Off bushings, space Heater with thermostat, 630A Copper busbars and support insulators, provision for earthing, all mounting accessories as required complete as per the requirement of Kerala State Electricity Board. The metering cubicle shall have glass window for meter reading.

1

-

-

... More
Supply of the following size 11 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date.3X300 Sq mm

295

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

250

-

-

... More
8.4.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm

45

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

6

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

2

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

10

-

-

... More
TRANSFORMER

-

-

-

... More
Supply, Installation, Testing and Commissioning of 500kVA,11kV/433V, 3 phase, Copper Winding, AirNatural Cooling,DYN-11 Dry Type Indoor Transformer, Tappings from 5% to - 15% in steps of 1.25%,with vacuum type OLTC with RTCC and Incoming cable box suitable for 11 KV 3Cx 300 sq.mm XLPE cable and LV side suitable for 3RX3.5CX400Sqmm cable , as per IS 2026/IS 11171. Transformer losses shall be as per ECBC guidelines amended up to date.

1

-

-

... More
Supply,Installation, testing and commissioning of emergency isolation push button mounted in standard I.P 65 weather proof break glass enclosure to isolate the power Supplying to the building in case of emergency when the face glass is broken. Cost shall be including necessary connection to the trip coil of the equipment using 2C x2.5Sqmm copper armoured cable.

1

-

-

... More
DIESEL GENERATOR

-

-

-

... More
160KVA DG Set:- Supply, Installation, Testing and Commissioning of 160 kVA prime rated DG set with acoustic enclosure, DG control panel, protection and digital metering, controls and interlocks, CT s and transducers for all metering and protection with suitable size breaker, suitable for AMF operation and synchronization, antivibration mountings, exhaust silencer etc. conforming to latest environment protection regulations for emission and noise levels, water/coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz,3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications. The work should be as per Electrical Inspectorate / pollution control board standards and comply to latest CPCB IV plus norms.(Civil works excluded).

1

-

-

... More
380KVA DG Set:- Supply, Installation, Testing and Commissioning of 380 kVA prime rated DG set with acoustic enclosure, DG control panel, protection and digital metering, controls and interlocks, CT s and transducers for all metering and protection with suitable size breaker, suitable for AMF operation and synchronization, antivibration mountings, exhaust silencer etc. conforming to latest environment protection regulations for emission and noise levels, water/coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz,3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications. The work should be as per Electrical Inspectorate / pollution control board standards and comply to latest CPCB IV plus norms.(Civil works excluded)

1

-

-

... More
EXHAUST PIPES:-Supplying and fixing exhaust gas piping of suitable dia, welded black M.S, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust.For 160kVA DG Set- 4 inch dia Exhaust pipe,

32

-

-

... More
EXHAUST PIPES:-Supplying and fixing exhaust gas piping of suitable dia, welded black M.S, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral Wool/ Rockwool,50 mm thick wire mesh aluminium cladding etc., as required as per specifications. suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. Horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbo charger and the vertical run of the pipes shall be provided with indirect supporting method so that when the pipes are hot and expanded they will be lifted into the supports. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust.For 380kVA DG Set- 6 inch dia Exhaust pipe

35

-

-

... More
DISTRIBUTION BOARDS

-

-

-

... More
4Way VTPN MCCB DB:-Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (4+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
6 way VTPN MCCB DB:-Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 6 way (4 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

2

-

-

... More
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required required 8 way (8+24) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
Supplying and fixing 16A to 100A TM TPN MCCB 25KA in the existing Vertical DB complete with connections,testing and commissioning etc. as required

5

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43).

4

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required: 6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43).

1

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8+12) - three phase double cover (IP 42/43)

18

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+24) - three phase double cover (IP 42/43)

1

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required, 6 way (8+18) - three phase double cover (IP 42)

20

-

-

... More
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door

7

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

795

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

6

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

50

-

-

... More
2.10.5 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral

5

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

7

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

11

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

90

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A 4P 100mA RCCB

8

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A 4P 100mA RCCB

25

-

-

... More
2.24.1 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB

18

-

-

... More
2.24.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB

20

-

-

... More
2.24.3 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 8 way, Double door TPN MCBDB

1

-

-

... More
2.23.2 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 2For 8 way, Double door SPN MCBDB

7

-

-

... More
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

10

-

-

... More
WIRING AND ACCESSORIES

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

801

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

10835

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

12450

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

4950

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

150

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

200

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

90

-

-

... More
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

80

-

-

... More
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

30

-

-

... More
1.57 : Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

18

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

710

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

936

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

710

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

936

-

-

... More
1.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push

8

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

60

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

20

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

640

-

-

... More
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

90

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

445

-

-

... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

40

-

-

... More
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module

20

-

-

... More
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module

60

-

-

... More
1.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module

20

-

-

... More
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module

90

-

-

... More
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module

20

-

-

... More
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

1077

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

636

-

-

... More
15.1 : Supplying,Installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10 Amp, for mounting height up to 2.8 Mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming and site etc. complete as required

60

-

-

... More
SUPPLY AND FIXING OF LIGHT FIXTURES

-

-

-

... More
SITC of LED Tube Lights of 34W(+/- 10% Tolerance) with minimum system lumens 3740 Lumens Extruded Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection inbuilt with electronic drive system, , SDCM5 and CCT in between 4000K to 5700K, power factor /= 0.95, THD10%,rated life of 50,000 hours at L70, system efficacy110 lm/W, with a CRI 80, or above, Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes.

130

-

-

... More
SITC of LED recessed downlight fixture Maximum 10W light fixture. System efficacy 110 lm/W and system lumen output not less than 1800 lm. Luminaire shall have satin finished translucence (HET) diffuser for uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19,SDCM5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same

126

-

-

... More
SITC of LED recessed downlight fixture Maximum 16W light fixture. System efficacy 110 lm/W and system lumen output not less than 1800 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19,SDCM5 and CCT in between 4000K to 5700K, Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated,copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same

220

-

-

... More
SITC of LED recessed downlight fixture Maximum 18W light fixture. System efficacy 110 lm/W and system lumen output not less than 1980 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with Die Cast Al powder coated housing, driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 19,SDCM5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple content is less than 10%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same

572

-

-

... More
SITC of of LED Tube Lights of 20W(+/- 10% Tolerance) with minimum system lumens 2200 Lumens Extruded Aluminium Profile linear batten and polycarbonate diffuser having driver of minimum 4KV Surge protection inbuilt with electronic drive system, , SDCM5 and CCT in between 4000K to 5700K,power factor /= 0.95, THD10%,rated life of 50,000 hours at L70, system efficacy110 lm/W, with a CRI 80, or above, Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same

48

-

-

... More
SITC of 2x2 LED Recess mounted light fixture 36W Clean Room light fixture. Bottom Opening frame. System efficacy 110 lm/W and system lumen output not less than 3960 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 22, SDCM5 and CCT in between 4000K to 5700K, Luminaire shall be flicker free with ripple content is less than 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same

48

-

-

... More
SITC of 2x 2 LED Recess mounted 30W light fixture, system efficacy 110 lm/W and system lumen output not less than 3300 lm. Luminaire shall have satin finished translucence (HET) diffuser for Uniform illumination and wider light distribution with CRCA powder coated housing, driver with minimum 4 KV internal surge protection with electronic drive system, power factor /=0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, UGR 22, SDCM5 and CCT in between 4000K to 5700K. Luminaire shall be flicker free with ripple factor 5%, ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make..

73

-

-

... More
SITC of LED Mirror Lights of Maximum 10W light fixture, System efficacy =100 lm/W and system lumen output not less than 1000 lm. driver with minimum 2.5KV internal surge protection with electronic drive system, power factor /=0.95, THD=20%, rated life of 50,000 hours at L70 with a CRI 80, SDCM5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make

10

-

-

... More
SITC of 10W LED BULKHEAD LIGHT fixture , System efficacy=100 lm/W and system lumen output not less than 1000 lm. , driver with minimum 2.50 KV internal surge protection with electronic drive system, power factor 0.95, THD10%, rated life of 50,000 hours at L70 with a CRI 80, SDCM5 and CCT in between 4000K to 5700K. ANSI rated LEDs from reputed makes should be provided and including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. all necessary accessories as required for the light fixture.LM79, LM80, type test certificate & BIS certificate shall be submitted, Luminaire/Drive shall be BIS approved of same make.

48

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote for speed control and all remaining accessories including safety pin, nut bolts, washers,temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required

180

-

-

... More
Supply, installation, testing and commissioning of wall fan of 450mm sweep, 1200 RPM, 70 Cu.Mtr/Min Air delivery. Plastic body & blades with pull cords for speed regulation & wide oscillation control. Aerodynamically designed blades for high air efficiency

9

-

-

... More
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)

13

-

-

... More
90.15.3.3 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 6 Meters

13

-

-

... More
15.4.3 : Supplying, installation, testing and commissioning of Astronomical time switch capable of following output in feeder pillars/ Lighting DBs for automatic switching On &OFF of street lights at sun set & sun ruse or twilight override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete ad required3 output (1output per phase) and suitable for three phase supply

1

-

-

... More
ISOLATORS

-

-

-

... More
SITC of MCB Isolator in sheet steel powder coated enclosure with lockable door facility confirming to IEC 60947-3 complete with all accessories, connections etc as required and as instructed by engineer in charge also making good any damages made during installation. 63A 4P MCB Isolator

1

-

-

... More
SITC of MCB Isolator in sheet steel powder coated enclosure with lockable door facility confirming to IEC 60947-3 complete with all accessories, connections etc as required and as instructed by engineer in charge also making good any damages made during installation. 16A to 40A 4P MCB Isolator

13

-

-

... More
SITC of MCB Isolator in (W/P) Enclosure with lockable door facility confirming to IEC 60947-3 complete with all accessories, connections etc as required and as instructed by engineer in charge also making good any damages made during installation. 50A 4P MCB Isolator (W/P)

1

-

-

... More
SITC of MCB Isolator in sheet steel powder coated enclosure with lockable door facility confirming to IEC 60947-3 complete with all accessories, connections etc as required and as instructed by engineer in charge also making good any damages made during installation. 25A 4P MCB Isolator with W/P enclosure

1

-

-

... More
SITC of MCB Isolator in sheet steel powder coated enclosure with lockable door facility confirming to IEC 60947-3 complete with all accessories, connections etc as required and as instructed by engineer in charge also making good any damages made during installation. 40A 4P MCB Isolator with W/P enclosure

1

-

-

... More
SITC of MCB Isolator in sheet steel powder coated enclosure with lockable door facility confirming to IEC 60947-3 complete with all accessories, connections etc as required and as instructed by engineer in charge also making good any damages made during installation. 16A 4P MCB Isolator with W/P enclosure

5

-

-

... More
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. 100A FP Isolator

1

-

-

... More
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accesories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. 200A FP Isolator

3

-

-

... More
Supply and fixing of following FP 415V, isolators in sheet steel powder coated enclosure with door interlock and padlock facility on surface confirming to IEC 60947-3 complete with all accessories, connections, testing and commissioning etc as required and as instructed by engineer in charge also making good any damages made during installation. 160A FP Isolator

2

-

-

... More
EXTERNAL FEEDER PILLAR

-

-

-

... More
EXTERNAL FEEDER PILLAR SITC of Thermoplastic polycarbonate Junction Box IP67 5pole terminals suitable to terminate up to 2.5sqmm. The color of Junction boxes shall be Siemens Grey RAL7035. The gasket should be internally embedded, and made of Polyurethane The boxes shall be tested as per IEC 60670-2 / 60670-22. The boxes shall have self- threaded holes provision for mounting din rail, The boxes should withstand temperature of -40c to +120c, The glow wire test should be conducted at 960c, and material should be flame retardant self- extinguishing. UL subject 94, V-0. The boxes should be free of toxic substances like halogen and silicon, The boxes should have suitable pre-molded knock out, suitable size IP68 polyamide glands shall be provided for in and out cables / wires. Incomer: 63A,TPN Isolator,63A ,30mA RCCB, Outgoing: 06 nos. 6/10/16/20A SP MCBs , 10KA.

1

-

-

... More
CABLE TRAY AND ACCESSORIES

-

-

-

... More
4.1.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

220

-

-

... More
4.1.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

95

-

-

... More
4.1.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

320

-

-

... More
4.1.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness

285

-

-

... More
4.2.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required150 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
4.2.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required225 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
4.2.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required300 mm width X 50 mm depth X 1.6 mm thickness

115

-

-

... More
4.2.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required450 mm width X 50 mm depth X 2.0 mm thickness

6

-

-

... More
4.3.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
4.3.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.200 mm width X 50 mm depth X 1.6 mm thickness

17

-

-

... More
4.3.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

9

-

-

... More
4.3.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

8

-

-

... More
4.5.2 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
4.5.3 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
4.5.4 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

9

-

-

... More
4.5.6 : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness

10

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

10

-

-

... More
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

12

-

-

... More
Supply and providing 2/3 mm thick synthetic type and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 5429/1969. ;

8

-

-

... More
Supply and providing 2.5/3 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 11 kV dielectric strength conforming to IS 5429/1969

20

-

-

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 liter capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters FIRE in black and gold or , duly painted over a coat of primer. Cost inclusive of providing 4 Nos of sand filled fire bucket and MS stand frame.

12

-

-

... More
Painting letters or figures of 2.5cm/4.5cm sizes with enamel paint as identification mark to SB, DB, panel board etc as required

1

-

-

... More
Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.

8

-

-

... More
Supplying and Providing 15 ; long rubber hand gloves

4

-

-

... More
Supply and fixing single line diagram, schematic diagrams etc. of A0 size including laminations etc. as required complete on wall

1

-

-

... More
Supply and fixing single line diagram, schematic diagrams etc. of A1 size including laminations etc. as required complete on wall

2

-

-

... More
Supply and providing First Aid Box.

2

-

-

... More
Supply and providing 6mm thick MS chequered plates duly painted. Plates to be cut size as per site requirement.

20

-

-

... More
UPS

-

-

-

... More
20 KVA (Standalone System) with Three Phase Input and Output :- The Three Phase input Voltage shall be 4wire, 415V, variable between +20% to –20%; 50Hz +/- 6%. The UPS System shall deliver Clean; ripple free output waveform in presence as well as failure of supply mains. The current and voltage harmonic distortions generated by the UPS systems shall be with in acceptable limits as per international and national norms. (Ripple [without Battery 1 %]), (THD 2% max, for 100% Linear load 5% max, for 100% Non-Linear load). UPS system shall be Double conversion, Microprocessor based True On Line system with individual battery banks having in-built galvanic Isolation Transformer at output and own Cooling arrangements. UPS system shall be with LCD Display, 3 input and 3 output; with PWM IGBT based DSP control, 20 Minutes external SMF battery backup and auto by-pass. Specification for 20 KVA Online UPS INPUT : Input Voltage Range -3, 4 Lines + Ground, 415V ± 20% Power factor - 0.99br Frequency Range - 50 Hz, ± 10% Topology - IGBT based DSP control OUTPUT: Voltage Range - 415V ± 0.5%br Frequency Range - 50 Hz, ± 0.05% O/P Power factor - Minimum 0.9 THD (Linear Load) - 2% THD (Non Linear Load) - 5% Crest Factor - 3:1 Efficiency - 95% Over load capacity - 110% - 5min , 150% - 30s Battery backup time required is 20 Min. using External Exide / Amarraja / Rocket Make SMF Batteries for each UPS. The product of the offered battery Ah capacity and the total rated DC Bus voltage shall be a minimum of 30,000 (for SMF battery).

1

-

-

... More
100KVA Modular type N+1 UPS :-Supply of MODULAR UPS 1X125 kw FRAME With maximum 25kw modules in each frame of 3 phase modules three phase in and out with built in PRS configurations. with indoor (IP20) with surge protection system with 15 min backup battery @80 kW load battery sizing calculation to be provided from the OEM, with isolator for each bank of SMF battery of reputed approved make , Input pf 0.99, Input THDi 3%, double conversion technology with input 400V, 50Hz three phase, output 400V, 50Hz three phase, SNMP card for network monitoring, BMS compatibility etc. It shall be 100% generator compatible, with Efficiency 96 % and output power factor Unity (kva = kW), Eco mode Efficiency 99% and including all accessories etc as required. The acoustic noise at 1m of the system should be80dB.The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3, CE, IEC62040-4 or ISO14025 or equivalent relevant IS standard. The system shall be true online double - conversion DSP based UPS system and also UPS shall be with automatic & manual bypass switch. The system shall have 3 level IGBT rectifier and inverter. including rack and interconnecting cables. Battery backup time required is 15 Min. using External SMF Batteries.The product of the offered battery Ah capacity and the total rated DC Bus voltage shall be a minimum of 190,000vAH

1

-

-

... More
RISING MAINS AND TAP OFF BOXES

-

-

-

... More
Supply, installation, testing and commissioning as per IEC 61439 Part 6 indoor prefabricated sandwich type epoxy insulated compact (TPN with 100% neutral) Rising Mains IP54 enclosure with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating for use on 3 phase 4 wire 415 V 50Hz AC on wall, with high conductivity aluminium conductor with provision for tapping and fixing Tap off boxes.The bus bar shall be complete with flange end bends expansion joints end cover elbow copper flexible and connections wherever applicable as per site conditions made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 nos aluminium bus bars, continuous external earthing with 2 nos copper strip of 25 x 3 mm size (one on each side) including GI clamping brackets, suspenders angle iron bracket steel fasteners connecting to earthing system etc. as required. 630 amps 36KA Rising Mains..

48

-

-

... More
Supply, installation, testing and commissioning as per IEC 61439 Part 6 indoor prefabricated sandwich type epoxy insulated compact (TPN with 100% neutral) busbar trunking IP54 with aluminium bus bars having current density of 130 A/ sq cm at nominal current rating for use on 3 phase 4 wire 415 V 50Hz AC on wall/ ceiling/structure, with high conductivity aluminium conductor. The bus bar shall be complete with flange end bends expansion joints elbow copper flexible and connections wherever applicable as per site conditions made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 nos aluminium bus bars, continuous external earthing with 2 nos copper strip of 25 x 3 mm size (one on each side) including GI clamping brackets, suspenders angle iron bracket steel fasteners connecting to earthing system etc. as required. 630 amps 36KA Bus Trunking

80

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for and including thermal magnetic MCCB complete with necessary joints including clamping brackets,angle iron bracket steel fasteners, connecting to earthing system etc. as required. The plug in /tap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished 125A 25kA 4P MCCB in Tap off box

8

-

-

... More
Supply, installing, connecting to existing sandwich rising mains, testing and commissioning of following capacity Plug in / Tap off box for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick electro galvanised steel sheet enclosure, IP42, with provision for andbrincluding thermal magnetic MCCB complete with necessary joints including clamping brackets,angle iron bracket steel fasteners, connecting to earthing system etc. as required. The plug in /brtap off unit shall comply with IEC and BS standards. The routine test certificate as per IS / IEC and type test certificate of complete plug in / tap off unit shall be furnished 160A 25kA 4P MCCB in Tap off box

2

-

-

... More
LIGHTNING PROTECTION SYSTEM

-

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required.a) 2 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories

2

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required.b)4 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories.c)4 meter air terminal with Interception Tip mounted on Concrete Stone & Stainless Steel mounting accessories

6

-

-

... More
Providing and fixing Fully Solid Vertical Air terminals for wind stability as per IS/IEC -62305 part-3 For 1,2,3, 4 meter air terminal 16mm rod tapered to 10 mm aluminium rod meter rod: For 6, 8 meter 40mm rod tapered to 16mm and then to 10mm Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. Air terminal Joining Clip Stainless Steel SS 304 clamp required to connect horizontal air termination to vertical air termination;Lightning tested for 100 KA 10/350 micro sec waveform. This is required if using 17 KG stone supports. Stainless Steel Wall Clamp or 17 KG stone of 365 mm diameter, high level of stability is required to mount 1,2,3,4 meters. No of concrete stones/wall clamps depending on wind load needs to be considered. For 6 & 8 meter air terminalfor mounting: tripod stand or 3 nos & 4 nos respectively wall clamp will be required to withstand heavy wind load. Govt approved Indian labs test certificate required.b)4 meter air terminal with Interception Tip mounted on Stainless Steel Wall Clamp mounting accessories

2

-

-

... More
Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required.c)Conductor with Terrace Conductor Fibre Reinforce Concrete holder @ every 0.75 meters

10

-

-

... More
Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required.b)Conductor with Down Conductor Holder made of whether resistant plastic holder @ every 0.75 meters.

560

-

-

... More
Providing & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required.,a)Conductor with Parapet Holder made of whether resistant plastic holder @ every 0.5 meters

340

-

-

... More
Providing and fixing of Cross Connector/T Connector/Folding Clamp/Clamping Shoe/ Expansion Piece: to route vertical down conductor /mesh formation made of Aluminium Ferrule using screw free joints. Folding Clamp/Clamping Shoe for metal panels (up to 20mm thickness of the metal frame): Folding clamp /clamping shoe for metal frame thickness up to 20mm, made of stainless steel SS 304/316 grade , conforms to the requirements according to (IS/IEC 62305). Expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with straight Connector: using Aluminium Ferrule. Quick installation using crimp joints. Conforms to the requirements according to (IS/IEC 62305). Make sure all joints are strong and will be inspected at site. Galvanised Iron joints are not permitted to avoid risk of corrosion. Single bolt joints are not permitted to avoid risk of faulty loose joints and reduce risk of flash over. Govt approved Indian labs test certificate required.

60

-

-

... More
Providing and fixing of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor & 10mm dia copper coated solid steel round conductor having 100 microns of copper bonding . Conforms to the requirements according to (IS/IEC 62305).The enclosure should be outdoor glass-fibre reinforced polycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. The test link has to be straight and needs minimum 4 mounting screws for strong joints. Inspection of bimetallic corrosion at site required. Seperation of 8mm Aluminium & 10mm Copper bonded steel is required for future inspection and contractor has to make sure both conductors should not touch eachg other to avoid bimetallic corrosion. Single bolt joints are not permitted. Govt approved Indian labs test certificate required

21

-

-

... More
Providing and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant. Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required.

580

-

-

... More
Installation of Exothermic Weld Joints for 10mm round copper bonded steel conductor having 100 microns as per IS/IEC 62305. Each under ground joints has to be wrapped with petrolatum- coated chemical fibre fabric having 1.1mm thick and width 50mm. Govt approved Indian labs test certificate required.

27

-

-

... More
Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 3048mm length (10 feet), having a diameter of 20mm with copper bonding thickness of 250 microns as per UL 467. The Rod has to be either continuous or with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Ordinary Stainless steel/Copper alloy universal clamps are not recommended. For self coupling peg & bore arrangement rod needs Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 m. It should be free from hazardous substances. The mineral compound is required to have minimum 17.5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. FRP Earth electrode inspection chamber FRP Earth electrode inspection chamber with weight bearing capacity of 60KN. The dimension shall be 290mmx 290mmx 209mm. Govt approved Indian labs test certificate required.

4

-

-

... More
EARTHING

-

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor (10 SWG)

660

-

-

... More
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 4.00 mm (8 SWG)

568

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 3 mm copper strip

954

-

-

... More
90.16.3.10 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 25 x 6 mm copper strip

315

-

-

... More
90.16.3.16 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run) 50 x 6 mm copper strip

224

-

-

... More
Supply of all materials and providing plate earth station with 1200 x 1200 x 12.5 mm. C.I. plate earth electrode, water pipe, earthing strips, clamps, funnel, Electrodes etc., excavation in all classes of soil,terminal filling with homogeneous mixture of charcoal and salt and back filling ,construction of Earthpit Inspection Chamber and Heavy duty C.I. Chequered plate for Earthpit Inspection Chamber cover. The rate quoted shall be including the excavation, construction of chamber, CI cover back filling

11

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling ,including necessary clamps and bolts etc. and all accessories as required for complete installation as instructed by engineer in charge/consultant. 25x3 Cu strips tinned at the point of contact. ;

218

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. 50X6 Cu strips tinned at the joints

412.85

-

-

... More
Supply and laying the following sizes of Cu strips laid 0.6 m below ground level including excavating trench of suitable size and refilling, including necessary clamps and bolts etc and all accessories as required for complete installation as instructed by engineer in charge/consultant. 25x6 Cu strips tinned at the joints

160

-

-

... More
PANELS AND ACCESSORIES

-

-

-

... More
MAIN PANEL:-Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with 14 SWG CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, CT chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grade for CT leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates.The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.br Incomers:brEB Incomer 1 - 800A, 36kA, FP, EDO Microprocessor based ACB with 3 O/C and 1 E/F releases. Standby low set E/F relay with CT at neutral earthing conductor, O/V relay with primary trip - 1 SetbrDG Feeder 1 from 160KVA DG - 250A, 36kA, FP, Microprocessor based MCCB and 250A FP AC3 contactor with 3 O/C and 1 E/F releases , overload and E/F release Standby low set E/F relay with CT at neutral earthing conductor + Necessary rating neutral contactor - 1 Sets.brDG Feeder 2 from 380KVA DG - 630A, 36kA, FP, EDO, Microprocessor based ACB with 3 O/C and 1 E/F releases , overload and E/F release Standby low set E/F relay with CT at neutral earthing conductor + Necessary rating neutral contactor – 1 Setsbr800A 415V, 36kA best conductivity Al FP bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement Digital LED power quality meters with necessary 0.50 accuracy class CT and accessories for measuring Voltage, Current, Frequency, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interrupts, Phase angle, THD, Neutral current, Max Demand (with RTC),Events (high-low) with time stamp, Individual Harmonics upto 31st, Meter with Ethernet Port - 3 setsbrRYB phase indicating LED lamps with control fuses and switches- 3 set.brClass B & Class C/ Class 1 & Class 2 Surge arrestor device with necessary HRC Fuse for back-up protection - 2 Sets.brOutgoings:bra) 630A 36kA TP+NL Microprocessor Based MCCB - 2 Nosbrb) 400A 36kA TP+NL Microprocessor Based MCCB - 5 Nosbrc) 250A 36kA TP+NL Microprocessor Based MCCB - 1 Nos d) 160A 36kA TP+NL Microprocessor Based MCCB - 7 Nosbre) 320 A TP+NL Isolator - 1 No.brf) RYB phase indicating LED lamps with control fuses and switches- 16 Set.g) MFDM supporting RS485,with 2A fuse and necessary CT_16 Set.brOriginal copy of design verification certificate of the respective OEM shall be submitted with the panel. The panel shall be with PLC components for interlocking of DG set with transformer and synchronisation of DG. Auto load sharing, AMF which includes synchronisation relays, UPS for PLC and all connections and interlocking required. Details to be as shown in SLD. All Breakers in the incoming side shall be with LSIG protection and all the breakers in the outgoing side shall be with LSI protection. ON/OFF/TRIP indicators shall be provided for all the breakers (incoming & outgoing). Necessary spreader terminals, exruded ROH, phase barriers, shrouding etc shall be as per the rules.

1

-

-

... More
CSSD PANEL:Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.brIncomer:-a)1 No 150A TPN ISOLATORbrb)1 Set RYB Indication Lamp c)1 Nos 150/5A CL:1, 15VA CT d)1 No (0- 150 ) A three phase digital ammeter e)1 No (0-500) V digital Voltmeter f)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PFbrOutgoings:-bra)1 Nos 80A, 25 kA, TM TPN, MCCBbrb)3 Nos 32A, 25 kA, TM TPN, MCCBbrc)2 Nos 25A, 25 kA, TM TPN, MCCBbrbr150A 415V 25kA best conductivity Al 4P bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
MEDICAL IMAGING PANEL:-Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 150A TPN ISOLATOR b)1 Set RYB Indication Lamp c)3 Nos 150/5A CL:1, 15VA CT d)1 No (0- 250 ) A three phase digital ammeter e)1 No (0-500) V three phase digital voltmeter f)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:- a)1 Nos 120A, 25 kA, TM TPN, MCCB b)1 Nos 80A, 25 kA, TM TPN, MCCB c)2 Nos 63A, 25 kA, TM TPN, MCCB 150A 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
MEDICAL GAS PANEL/ SSB LGF /SSB TF (SMDB -6WAY) :-Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 6 way complying to IEC 61439 Part 1 & 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters & indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge. Incomer – 1 No. 63A 25KA TPN MCCBbrOutgoings: - a)3 Nos 40A, 25KA TP, MCCB b)3 Nos 32A, 25KA TP, MCCB

3

-

-

... More
UPS O/P PANEL:-Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.brIncomer:-bra)1 No 160A TPN ISOLATORbrb)1 Set RYB Indication Lampbrc)1 Nos 150/5A CL:1, 15VA CTbrd)1 No (0- 150 ) A three phase digital ammeter bre)1 No (0-500) V three phase digital voltmeter f)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PFbr Outgoings:-bra)1 Nos 150A, 25 kA, TM TPN, MCCBbrb)3 Nos 63A, 25 kA, TM TPN, MCCBbrc)5 Nos 32A, 25 kA, TM TPN, MCCBbrbr160A 415V 25kA best conductivity Al 4P bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
SSB-CHILLERbrSupply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.brIncomer:-bra)1 No 200A TPN ISOLATORbrb)1 Set RYB Indication Lampbrc)3 Nos 200/5A CL:1, 15VA CTbrd)1 No (0- 200 ) A three phase digital ammeter e)1 No (0-500) V three phase digital voltmeter f)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PFbr Outgoings:-bra)4 Nos 160A, 25 kA, TM TPN, MCCBbrb)1 No 200/5A CL:1, 15VA CTbrc)3 Nos 150/5A CL:1, 15VA CTbrd)4 Nos of Multifunction Digital meter V,A,F,KW,KVA,PFbre)4 Set RYB Indication Lampbrbr200A 415V 25kA best conductivity Al 4P bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
HVAC PUMP PANEL: brSupply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.brIncomer:-bra)1 No 100A TPN ISOLATORbrb)1 Set RYB Indication Lampbrc)3 Nos 100/5A CL:1, 15VA CTbrd)1 No (0- 100 ) A three phase digital ammeterbre)1 No (0-500) V three phase digital voltmeter f)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PFbr Outgoings:-bra)11 Nos 32A, 25 kA, TM TPN, MCCB brb)1 Nos 63A, 25 kA, TM TPN, MCCBbrc)12 Set RYB Indication Lampbrbr100A 415V 25kA best conductivity Al 4P bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.br

1

-

-

... More
SSB UTILITY PANELbrSupply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level.Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.brIncomer:-bra)1 No 320A TPN ISOLATORbrb)1 Set RYB Indication Lampbrc)1 Nos 400/5A CL:1, 15VA CTbrd)1 No (0- 400 )A three phase digital ammeter e)1 No (0-500)V three phase digital voltmeterf)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF Outgoings:-bra)1 Nos 200A, 25 kA, TM TPN, MCCBbrb)3 Nos 125A, 25 kA, TM TPN, MCCBbrc)1 Nos 80A, 25 kA, TM TPN, MCCBbrd)1 Nos 63A, 25 kA, TM TPN, MCCBbre)6 Set RYB Indication Lampbrbr400A 415V 25kA best conductivity Al 4P bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
SDB PHE Panel :-brSupply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. All panels must be BMS compatible. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.brIncomer:-bra)1 No 150A TPN ISOLATORbrb)1 Set RYB Indication Lampbrc)3 Nos 300/5A CL:1, 15VA CTbrd)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PFbrOutgoings:-bra)1 Nos 80A, 25 kA, TM TPN, MCCBbrb)1 Nos 63A, 25 kA, TM TPN, MCCBbrc)1 Nos 50A, 25 kA, TM TPN, MCCBbrd)1 Nos 40A, 25 kA, TM TPN, MCCBbre)1 Nos 32A, 25 kA, TM TPN, MCCBbrbr150A 415V 25kA best conductivity Al 4P bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
SMDB PUMP:-1 -8WAY:-Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 8 way complying to IEC 61439 Part 1 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge. Incomer – 1 No. 80A 25KA TPN MCCB Outgoings: - a)2 Nos 63A 25KA TPN, MCCB, b) 2Nos 32A TP 25KA MCCB, c) 4Nos 25A 25KA TPN MCCB

1

-

-

... More
SSB-2F(SMDB -8WAY):-Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 8 way complying to IEC 61439 Part 1 & 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters & indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge.Incomer – 1 No. 100A 25KA TPN MCCBbr Outgoings: - a) 3 Nos 32A TP 25KA MCCB b) 5 Nos 40A TP 25KA MCCB

2

-

-

... More
SSB 4F PANEL: brSupply, Installation, TestingS and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 & 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 & form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory.brIncomer:-bra)1 No 125A FP ATSbrb)2 Set RYB Indication Lampbrc)1 Nos 125/5A CL:1, 15VA CTbrf)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF g) 1 no (0-120)A three phase digital ammeter h) 1No (0-500)V three phase digital voltmeter brOutgoings:-bra)1 Nos 100A, 25 kA, TM TPN, MCCBbrb)3 Nos 63A, 25 kA, TM TPN, MCCB 125A 415V 25kA best conductivity Al 4P bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD

1

-

-

... More
SSB GF / SSB 1F (SMDB -8WAY):-Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 8 way complying to IEC 61439 Part 1 & 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters & indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge. Incomer – 1 No. 100A 25KA TPN MCCB Outgoings: - a)1 Nos 63A, 25KA TP, MCCB, b) 7 Nos 32A TP 25KA MCCB.

2

-

-

... More
SDB LIFT PANEL (SMDB -4WAY):- Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz 4 way complying to IEC 61439 Part 1 & 2. The Enclosure shall be IP42 with cable end box, cable alley, pre wired meter chamber with all meters & indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge. Incomer – 1 No. 120A 25kA TPN MCCBbrOutgoings: - 4 Nos 63A, 25KA TPN, MCCB

1

-

-

... More
LIFT PANEL(TYP) :-Supply, Installation, Testing andbrcommissioning of factory fabricated OEM 415 V 50Hz 4 way complying to IECbr61439 Part 1 & 2. The Enclosure shall be IP42 with cable end box, cable alley,brpre wired meter chamber with all meters & indicating lamps, Aluminium bus bar, neutral link, DIN bar with all accessories etc. complete with necessary control wiring and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level complete as per the directions of Engineer in charge.Incomer – a)1 No 63A TPN ISOLATOR Outgoings: -a) 1 Nos 40A, 4P 100mA RCBO b) 1Nos 25A, DP 30mA RCBO c) 4 Nos 6A, SP MCB

3

-

-

... More
SDB EV CHARGING : Supply, Installation, Testing and Commissioning of 415 V 50Hz OEM design verified LT Switch board complying to IEC 61439 Part 1 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42, Impact protection shall be IK10 form of construction 3B or better. Cable entry facility shall be at top or bottom (as per site condition) with necessary cable alleys, switchgear compartments, meter chambers, C.T chambers, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with appropriately rated HRC fuses. Doors shall be earthed as per standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Gland plates shall be 3mm thick and knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum up to 1800mm from the finished floor level. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. OEM certification is also mandatory. Incomer:- a)1 No 100A TPN ISOLATOR b)1 Set RYB Indication Lamp c)3 Nos 100/5A CL:1, 15VA CT d)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF e) 1No.(0-100)A three phase digital ammeter f)1No (0-500)V three phase digital voltmeter Outgoings:- a)1 Nos 63A, 25 kA, TM TPN, MCCB b) 6 Nos 25A, 25 kA, TM TPN, MCCB 100A 415V 25kA best conductivity Al bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD.

1

-

-

... More
APFC PANEL-125KVAR: Supply, Installation, Testing and Commissioning of factory fabricated OEM 415 V 50Hz LT Switch board design verified assembly panel complying to IEC 61439 Part 1 2. The Enclosure shall be self-supported, free standing powder coated compartmentalized cubicle type with CRCA sheet, Ingress Protection rating shall be IP42 Impact protection shall be IK10 with cable entry facility at top or bottom (as per site condition), cable alley, switchgear compartment, meter chamber, C.T chamber, Aluminium bus bar with bus bar chamber etc. Control wiring shall be with 2.5 sq.mm copper cable of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads and protection of control shall be with DIN rail mounted 2A SP MCB. Doors shall be earthed as per prevailing standards. The main earth bus shall be of suitable size copper and run through the switch board for earthing metallic parts of switch gears. All copper joints shall be tinned. Knock - outs of proper diameter shall be provided on gland plates. The height of the operating handle of any switch gear shall be minimum 300mm and maximum upto 1800mm from the finished floor level.Form of construction of panel shall be 3B or above. Note: Relevant Test certificates from third party certification agencies: ASTA, ASEFA, DEKRA, KEMA, UL will be accepted as proof of compliance. Adequate forced ventilation arrangement shall be provided by means of a cubicle type fan of capacity 225 m3/hr also with contactor thermostat control. Control fuses shall be provided for the fan circuit. Lamp indication shall be provided to indicate the working/ nonworkingstates of the fan. The capacitor compartment shall be so constructed that in case of any capacitor failure, fluid leakage or fumes from the field capacitor shall not affect the capacitors in the other compartments. The inter-compartmental partition of capacitor chamber shall be perfectly done. The capacitor shall be rated for a voltage 480 V or above and conform to IS - 2834. Incomer a) 315A TPN Isolator-1No Outgoings a)100A TPN 25KA MCCB-2Nos. b)80A TPN 25KA MCCB-1 Nos. c)63A TPN 25KA MCCB-1 Nos d)40A TPN 25KA MCCB-1 Nos f)25A TPN 25KA MCCB-3Nos Capacitor: 30kVAR Capacitor Duty Contactor - 2 Nos 25kVAR Capacitor Duty Contactor - 1 No 20kVAR Capacitor Duty Contactor - 1 No 10kVAR Capacitor Duty Contactor - 1 Nos 5kVAR Capacitor Duty Contactor - 3 No 30kVAR Heavy Duty Capacitor Box Type Resin Filled -2 Nos 25kVAR Heavy Duty Capacitor Box Type Resin Filled -1 Nos 20kVAR Heavy Duty Capacitor Box Type Resin Filled -1 No 20kVAR Heavy Duty Capacitor Box Type Resin Filled -1 No 10kVAR Heavy Duty Capacitor Box Type Resin Filled -1 No 5kVAR Heavy Duty Capacitor Box Type Resin Filled -3 No 7% detuned reactor – 8 nos. 8 Stage APFC Relay - 1 No 400A 415V 36kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required with necessary interlocking arrangement. Details to be as shown in SLD. Complete with all Control Wiring Components such as Control Contactors, Selector Switch, Push Button with Elements, Control MCB s etc. as required.

1

-

-

... More
Supply, erection, testing and commissioning of following capacity auto transfer switch with enclosure, bus bars and all accessories required for complete operation as per the drawing. The ATS should be double break contact system for high short time withstand. ATS shall be with UV/OV, Phase sequence, Single phasing and frequency protections. 100A 4P ATS WITH ENCLOSURE

4

-

-

... More
LT Cabling and End Termination

-

-

-

... More
90.12.1.34 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5 core 185 sq mm

70

-

-

... More
90.12.1.37 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5 core 400 sq mm

140

-

-

... More
90.12.1.29 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 3.5 core 50 sq mm

90

-

-

... More
90.12.1.39 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq mm

80

-

-

... More
90.12.1.40 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm

25

-

-

... More
90.12.1.42 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 25 sq mm

20

-

-

... More
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp

140

-

-

... More
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm

410

-

-

... More
90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm

310

-

-

... More
90.12.7.32 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm

190

-

-

... More
90.12.7.33 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm

115

-

-

... More
90.12.7.34 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

290

-

-

... More
90.12.7.35 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm

290

-

-

... More
90.12.7.37 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 400 sq mm

60

-

-

... More
90.12.7.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp

30

-

-

... More
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp

135

-

-

... More
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

1400

-

-

... More
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

800

-

-

... More
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp

345

-

-

... More
90.12.7.43 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp

195

-

-

... More
90.12.7.12 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with factory made clamp

75

-

-

... More
90.12.7.13 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp

340

-

-

... More
90.12.7.14 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 10 sq mm with factory made clamp

40

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3Cx4 sq.mm CU Ar Cable 3Cx4 sq.mm CU Ar Cable

292

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 1Cx95sq.mm CU flexible Cable

150

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 3Cx6sq.mm CU Cable

39.01

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4Cx4sq.mm CU Cable

30

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 4Cx6sq.mm CU Cable

105

-

-

... More
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, Copper conductor 2XFY power cable confirming to IS 7098 (part 1) amended up to date. 1Cx16sq.mm CU flexible Cable

180

-

-

... More
Supply of following size 1.1 kV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date. 12CX2.5 (Cu Control cable)

145

-

-

... More
Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 12Cx2.5 Sqmm Cu Control cable

4

-

-

... More
9.1.7 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)

4

-

-

... More
9.1.16 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 185 sq. mm (57mm)

12

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

16

-

-

... More
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)

32

-

-

... More
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)

12

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

6

-

-

... More
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

4

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

12

-

-

... More
9.1.29 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)

8

-

-

... More
9.1.31 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm)

10

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

82

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

36

-

-

... More
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

12

-

-

... More
9.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)

10

-

-

... More
90.12.24.5 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.16 sq mm

20

-

-

... More
90.12.24.10 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.95 sq mm

20

-

-

... More
SUBHEAD 4 - HVAC WORKS WATER CHILLING PLANT

-

-

-

... More
Supply at site including local transport with full cover insurance,fire or any other contingencies, unload, store, handle, erect, balance, test and commission the entire water chilling plant as per specifications including all accessories as specified for water chilling plant. WATER COOLED SCREW CHILLER - (R- 134A/410) OF MINIMUM CAPACITY 80 TR. Minimum Overall Chiller efficiency offered shall have COP 5.8 AS PER ECBC + Buildings 2017/ ASHRAE / ARI 550/590 & IPLV 7.1, Summer Ambient conditions: DBT – 95 deg F, WBT- 82 Deg F, Comprising of Screw Compressor as per specifications. Drive motors of suitable ratings 415+/- 10% Volts 50 Hz AC supply and starter panel with star delta starter. Water cooled condenser with all accessories. Automatic capacity control unit to regulate the capacity down to 25%. Micro-processor control panel. Building management system compatible software Data Link / Micro Gateway for integration with third party BMS on Modbus / BACNET protocol, Safety controls as per spec. wiring and interlock between pumps shall be included in the chiller cost. The cost for additional incoming metering panel for each chiller to be included in the chiller. Water cooled chiller with all accessories: LOTintegral mounting frame for all the components, LOT-refrigerant piping & valves, LOT-insulation of chiller and suction line(in compliance with ECBC + building guidelines), LOT-first charge of refrigerant and lube oil, LOT-vibration isolation pads. LOT Thermometer for water inlet and outlet and water flow switches. MCCB's as a part of the chiller. Copper cable & isolators for chiller to be included in the chiller cost. Chiller shall be ASME U stamped. Compressor, condenser and evaporator shall be manufactured by OEM itself.

2

-

-

... More
PUMPS AND COOLING TOWER

-

-

-

... More
Supply, installation, testing & commissioning the chilled water primary pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Mechanical efficiency of Pump shall be minimum 75% as per ECBC + Buildings 2017 and motor efficiency shall be minimum IE3.Capacity: 192 USgpm, 1440 RPM (Suggested), Head: 45 feet.

3

-

-

... More
Supply, installation, testing & commissioning the chilled water secondary pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Mechanical efficiency of Pump shall be minimum 75 % as per ECBC + Buildings 2017 and motor efficiency shall be minimum IE3. Capacity : 192 USgpm, 1440 RPM (Suggested), Head : 90 feet.

3

-

-

... More
Supply, Installation, Testing & commissioning of Variable Frequency Drive complete IP 20 VSPS control panel (IP 55 if panel is to be installed under open air) consisting of adjustable frequency drive (AFD) for each pump, one dedicated microprocessor based pump controller per zone housed within this enclosure panel with parallel pumping software duly down loaded and differential pressure sensor / transmitters as per the site requirement. The entire system along with secondary pumps as described above must be sourced from single manufacturer only, to ensure unit responsibility. The VFD should be incorporated with RFI (radio frequency interface) filters which can control THDi complying to IEEE519 standards, auto bypass starter compactable to the third party BMS.

1

-

-

... More
Supply, Installation, testing & commissioning the condenser water pumps as per specification including all accessories as specified and as required. Including Factory made base frame & fixing foundation with necessary fittings as required. End suction Chilled water Pump sets complete with TEFC sq.cage induction motor (WITH MECHANICAL SEAL) stainless steel shaft, bronze impeller, End Suction Long coupled Type, base plate couplings, pressure gauges (2 Nos. with syphon and gauge cock, anti vibration springs. guards etc. including insulation as per specifications. Mechanical efficiency of pump shall be 75% as per ECBC + Buildings 2017.Motor efficiency shall be minimum IE 3. Capacity: 320 USgpm, 1440 RPM (Suggested), Head: 70 feet.

3

-

-

... More
Supply, Installation, testing & commissioning the cooling towers as per specification including all accessories as specified and as required. COOLING TOWERS with VFD of actual capacity complete in all respects as per technical specifications and equipment schedule complete with FRP casing, FRP fan cylinder, PVC louvers, PVC drift eliminator polypropylene nozzles, drive assembly, HDG fan guard/bird screen, non-clogging nozzle type water distribution system. PVC fill, GI ladder with railings, make up water, quick fill and drain over flow connections with valves & fittings etc. as per specifications. Including R.C.C foundation along with PCC/RCC sub base, fixing with bolts and nuts and finishing the slabs 80 TR -TI/JCI approved induced draft,cross/counterflow cooling tower with vertical air discharge. Cooling towers shall meet or exceed the minimum efficiency requirements specified for ECBC+ buildings. EWT = 97.5 degree F, LWT = 90 degree F, WET bulb = 82 degree F, Flow rate = 320 USgpm. Motor efficiency shall be minimum IE 3 rated. VFD shall comply IEEE519 standards.

2

-

-

... More
DOUBLE SKIN AIR-HANDLING UNITS WITH VFD PLUG FANS and THERMAL BREAK ,FAN COIL UNITS AND VAV

-

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF 1 TR Hideway FCU

2

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF) 1.5 TR Hideway FCU

3

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF) 2 TR Hideway FCU

4

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF)2.5 TR Hideway FCU

3

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF) 3 TR Hideway FCU

1

-

-

... More
Supply, installing, testing and commissioning of Fan Coil Units each complete with filters of 20 micron filtering capacity, coil section with chilled water cooling coil and fan section with forward curved multi blade centrifugal blower and suitable TEFC Sq.cage induction motor, extended drain pan copper connections from isolating ball valve to fan coil unit cooling coil complete with flare-nuts, nipple, brazing of pipe joints, etc. with expansion loop, providing and fixing GM ball valve (with SS ball) with Y strainer for inlet of cooling coils, pipe connection between drain outlet and drain piping with 2nos. hose S clamps, providing and fixing male-female Copper connections from isolating ball valve to fan coil unit cooling coil (15mm/19mm OD) complete flare-nuts nipple, brazing of pipe joints etc. with expansion loop, extended tray double skin & with room thermostat cum fan speed selector switch. Including 2 Way Type PRESSURE INDEPENDENT VALVE spring return type (ON/OFF) 4 TR Hideway FCU

1

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and by pass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of IE 3 rating including mounting and fixing arrangements. Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron.Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications.Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 5 TR, 2000 cfm, 6 sqft./ 4row (Double Skin Ceiling Suspended AHU) [10 micron]

1

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and by pass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of IE 3 rating including mounting and fixing arrangements. Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 7 TR, 1000 cfm, 2 sqft./ 8 row (Double Skin Ceiling Suspended AHU) [Treated Fresh air AHU] filtration [10 micron]

1

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and by pass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of IE 3 rating including mounting and fixing arrangements. Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting /plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 4TR, 1600 cfm, 3.2 sqft./ 6row (Double Skin Ceiling Suspended AHU with mixing Box 10 micron pre filters , 5 micron fine filters, heater, Thermal break, germicidal UV-C lamps etc.)

1

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and by pass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of IE 3 rating including mounting and fixing arrangements. Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 3TR, 1200 cfm, 2.4 sqft./ 6row (Double Skin Ceiling Suspended AHU with mixing Box, 10 micron pre filters , 5 micron fine filters, heater, Thermal break, germicidal UV-C lamps etc.)

3

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and by pass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of IE 3 rating including mounting and fixing arrangements. Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs.Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 10TR, 4000 cfm, 8.0 sqft./ 6row (Double Skin floor mounted Horizontal unit with mixing box, 10 micron pre filters , 5 micron fine filters, heater, Thermal break, germicidal UV-C lamps etc.)

1

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and by pass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of IE 3 rating including mounting and fixing arrangements. Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 10TR, 3000 cfm, 6.0 sqft./ 6row (Double Skin Ceiling mounted Horizontal unit with mixing box, 10 micron pre filters , 5 micron fine filters, heater, Thermal break, germicidal UV-C lamps etc.)

1

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and by pass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of IE 3 rating including mounting and fixing arrangements. Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 8 TR, 3200 cfm, 6.4 sqft./ 6row (Double Skin Floor Mounted AHU with mixing Box, 10 micron pre filters , 5 micron fine filters, heater, Thermal break, germicidal UV-C lamps etc.)

1

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and by pass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of IE 3 rating including mounting and fixing arrangements. Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 6TR, 2400 cfm, 6 sqft./ 6row (Double Skin Ceiling Suspended AHU with mixing Box, 10 micron pre filters , 5 micron fine filters, heater, Thermal break, germicidal UV-C lamps etc.)

1

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and by pass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of IE 3 rating including mounting and fixing arrangements. Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 5TR, 600 cfm, 1.4 sqft./ 8 row (Double Skin Ceiling Suspended AHU with mixing Box, 10 micron pre filters ,5 micron fine filters, heater, Thermal break, germicidal UV-C lamps etc.)

2

-

-

... More
Supply, Installation, testing & commissioning the AHU's as per specification including all accessories as specified and as required VFD driven AHU with plug fans and VFD, Bypass starter with all necessary connections with pressure sensors (minimum 2 nos.) and cabling to be included.Only HVAC application VFD's shall be used All AHU’s will be given only one power input cable. Any looping should be done by OEM in case of multiple motors in one AHU Pre-Plasticised Sheet/ powder coated , Extruded Aluminium panta post frame work Fan section, coil section, filter section, with necessary Insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10fins per inch) and required number of rows deep. TEFC sq. cage induction motor of required rating including mounting and fixing arrangements.IE 3 rated Plug fan with VFD Drives. Anti vibration springs/ isolator bearings etc. 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron. Insulation of all section with fire retardant insulation material as per manufactures standard. Air vent on cooling coil with globe valve/screwed plugs. Insulation of Drain pan as per specifications. Double canvas connections of fire retardant quality for connecting AHU's to ducting/plenum. Insulated drain piping with trap till the out let of the AHU Balance will be measured in the chilled water piping, Thermostat, Thermowell at the inlet and outlet of cooling coils, gauge cocks at the inlet and outlet of coiling coils for pressure gauges (only provision), Duct damper including Control wiring to make M/V in close position while AHU is OFF with relays etc. Including R.C.C foundation along with PCC/RCC sub base with bolts and nuts and finishing the slabs or any opening etc. good as same Limit switch in door and inspection lamps to be fixed Lockable off push button to be provided near AHU if machine is 3mtrs and above far from respective panel board to be included in the Ahu cost. 3.5 TR, 1600 cfm , 3.2 sqft. / 8 Row-(Double Skin Ceiling Suspended AHU with mixing Box, 10 micron pre filters ,5 micron fine filters, heater, Thermal break, germicidal UV-C lamps etc.)

1

-

-

... More
CHILLED WATER PIPING AND VALVES

-

-

-

... More
16.3.6 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 150mm dia. (50mm thick expanded polysterene)

45

-

-

... More
16.3.5 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 200mm dia. (75mm thick expanded polysterene)

145

-

-

... More
16.3.7 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of Nominal size - 125mm dia. (50mm thick expanded polysterene)

40

-

-

... More
16.3.8 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 100mm dia. (50mm thick expanded polysterene)

20

-

-

... More
16.3.9 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 80mm dai. (50mm thick expanded polysterene)

125

-

-

... More
16.3.10 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 65mm dia.(50mm thick expanded polysterene)

110

-

-

... More
16.3.11 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 50mm dia. (50mm thick expanded polysterene)

280

-

-

... More
16.3.12 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 40mm dia. (50mm thick expanded polysterene)

110

-

-

... More
16.3.13 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 32mm dia. (50mm thick expanded polysterene)

245

-

-

... More
16.3.14 : Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/ cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63 aluminium sheet cladding complete with type 3, grade , roofing feltstrip (as per IS: 1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The pipes of sizes 150 mm & below shall be M.S.'C" class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7 mm thick MS sheet for pipes of 400 mm dia and above.Chilled water piping of nominal size - 25mm dia. (50mm thick expanded polysterene)

240

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 20mm dia..

152

-

-

... More
Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection.100 mm dia

110

-

-

... More
Site fabricated pipe (MS class B) with adequate structural support and with PUF injection insulation & GI cladding for part plant room & AHU room area & valve insulation with openable boxing for inspection.200 mm dia

75

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same." 32 mm dia. PVC

25

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same." 25 mm dia. PVC

100

-

-

... More
DRAIN WATER PIPING: Supply and fixing in position of condensate drain water & AHU room drain pipe to the floor trap/nearest drain piping with 25 mm nitrile rubber insulation and with necessary fittings like traps, clamps, elbows, tees and reducers etc. Openings as good as same." 20 mm dia. PVC

150

-

-

... More
16.7.1.2 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 150mm

5

-

-

... More
16.7.1.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 50mm

22

-

-

... More
16.7.1.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 40 mm

14

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation: Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven.100 mm dia.

30

-

-

... More
16.7.1.1 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 200 mm

2

-

-

... More
16.7.1.3 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedButterfly valve (Manual) 125 mm

2

-

-

... More
16.7.1.5 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16 pressure rating for chilled water/hot eater circulation as specifiedBUTTERFLY VALVE (MANUAL) 80 mm

12

-

-

... More
BUTTERFLY VALVES for AHU, Chiller Plant, Floor isolation:Supply, installation, testing & commissioning of the following Butterfly valves as per the specifications and as required. Butterfly valve shall cast iron body with black nitrile seat. All butterfly valves shall be provided with locking devices & PN 16 Rating. Valve above 300 mm dia shall be gear driven.32 mm dia.

16

-

-

... More
Supply, installation, testing & commissioning of the following type forged Ball Valve, PN-20 gunmetal /cast alloy, including all necessary accessories and connections.25 mm dia

8

-

-

... More
Supply, installation, testing & commissioning of the following type forged Ball Valve, PN-20 gunmetal /cast alloy, including all necessary accessories and connections.20 mm dia

1

-

-

... More
16.7.3.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.NON- RETURN VALVE with duel plate of C I body SS plated vulcanized NBR Seal flanged end & PN 16 pressure rating for chilled/ hot water circulation including insulation as specified.NON- RETURN VALVE 100 mm dia

6

-

-

... More
16.7.2.4 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Balancing valve with built in measuring facility with C.I Body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation as specified.Balancing valve with built in measuring facility 100 mm dia

2

-

-

... More
SUCTION GUIDE with strainer: Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required.100 mm dia.

6

-

-

... More
16.7.4.7 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of Ductile of 50 mm dia

10

-

-

... More
16.7.4.8 : Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specifiedY- Strainer of 40 mm dia

2

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.Y- Strainer of Ductile CI Body flanged ends with stainless steel strainer for chilled/hot water circulation including insulation as specified Y- Strainer of 32 mm dia

8

-

-

... More
PRESSURE GAUGE - For chiller, pumps, AHU: Supply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type,made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection : Brass, NPS 12mm dia bottomoutlet type, Dial: Satin-faced, non-reflective aluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification"

56

-

-

... More
THERMOMETERS - For chiller, pumps, AHU: Supply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

56

-

-

... More
Supply, installation, testing & commissioning of differential pressure switch as per the specifications and as required.

2

-

-

... More
16.11.3.7 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.100mm dia.

3

-

-

... More
500 L Pressurized Tank:Design, supply, installation, testing and commissioning of Pressurised chilled water expansion tank with Make up connection for closed loop system along with necessary pneumatic devices and accessories and MS 'C' section supports in order to keep chilled water under pressure.The tank shall be precharged steel tank with replacable heavy duty butyl rubber bladder.The tank shall have 50mm system connection and 20mm drain and charging valve connection to facilitate onsite charging of tank.The tank shall be fitted with lifting rings and floor mounting skirt for vertical installation.The tank shall be constructed according to section 8 of ASME boiler and pressure vessel code and stamped 125psi working pressure.The contractor shall submit calculation regarding the above data. Pumps shall be of N+1 configuration. including with control wiring.

1

-

-

... More
Supply, installation, testing & commissioning of a common air separator on the chilled water return line located at the pump suction and suitable for Secondary pump water flow; the separator shall be complete with high capacity air vent, flanges, service valve, non return valve, isolation butterfly valve for makeup water inlet. Capacity suitable for 1428 USGPM and 250 mm NB CHW Header line

1

-

-

... More
AUTO AIR VENTS - Supply & install of air vents / purge valves including 15mm Ball Valves at the highest points in chilled water piping complete each floor with pipes nipple welded to pipe, hex nipple, socket, U-pipe connection at outlet of air vent etc. as required

25

-

-

... More
Supply and fix flexible connections with control rods for pumps and chiller.Size: 100 mm dia.

10

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE:Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type).50 mm dia.

10

-

-

... More
TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE:Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type).40 mm dia.

2

-

-

... More
"TWO WAY TYPE PRESSURE INDEPENDENT BALANCING CUM MODULATING FLOW CONTROL VALVE: Supply, Installation, testing and commissioning of following size Pressure independent type 2 way modulating flow Control valves in a single Unit of Valves with PN16 Rating. DN 15 to DN 32 Brass Body Ext. Threaded, DN 40 & DN 50 Cast Iron Body Ext. Threaded, DN 65 to DN 100 Cast Iron body, Flanged Ends Connection Duly mounted with a BMS compactable Modulating actuator IP54 Type suitable for 24V AC for AHU/FCU as per specification(spring return type)." 32 mm dia.

8

-

-

... More
CONDENSER WATER PIPING AND VALVES

-

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specfiications. Opening as good as same.200 mm dia.

110

-

-

... More
Supply, receive, store handle, install, test and commission the condenser water line with GI class (B) IS 3589 pipes complete with all fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, structural supports, etc. as reqd. for installation as per site conditions and as per specifications. Opening as good as same. 125 mm dia

75

-

-

... More
16.11.1.1 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedBUTTERFLY VALVE (MANUAL) 200 mm

2

-

-

... More
16.11.1.3 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Butterfly Valve ( Manual) with C I body SS disc nitrile sheet & O ring & PN 16 pressure rating as specifiedBUTIERFLY VALVE (MANUAL) 125 mm

20

-

-

... More
16.11.2.3 : Supplying, fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.Non- Return Valve with dual plate of C I body S S plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.Non- Return Valve of 125 mm dia

3

-

-

... More
Supply, installation, testing & commissioning of the following suction guides as per the specifications and as required.125 mm dia.

3

-

-

... More
Supply and fix flexible connections with control rods for pumps, cooling tower & condenser.125 mm NB.

10

-

-

... More
Supply, installation, testing & commissioning of Balancing Valve, with built in measuring facility with C.I Body, 90 Deg C maximum operating temperature; built-in locking device for Tamper-Proof positioning; flanged connections;Valves shall have connections with isolation device for portable differential pressure meter with integral seals, Flow accuracy shall be 5%+/- Size: 125 mm NB

2

-

-

... More
"THERMOMETERS - For chiller, pumps, AHU: brSupply, installation, testing and commissioning of 4 inch Dial type thermometers with Stem with Copper-plated steel, aluminum, or brass for thermowell installation and of length to suit installation, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

10

-

-

... More
PRESSURE GAUGE - For chiller, pumps, AHU:brSupply, installation, testing and commissioning of Indicating-dial type pressure gauges of Dry type,made of Stainless steel or cast aluminum case, 114-mm dia, Pressure-Element Assembly: Bourdon tube, Pressure Connection : Brass, NPS 12mm dia bottomoutlet type, Dial: Satin-faced, non-reflective aluminum with permanently etched scale markings, Pointer: Red or other dark-color metal, Window: Glass, Accuracy: Grade A, plus or minus 1 percent of middle half, Stainless Steel U-Siphon and 15mm Brass body ball valve as per specification

10

-

-

... More
16.11.3.6 : Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valves with Cl Body, SS Disc,O - ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC and upto 20mA electric signal and providing similar transduced feedback output to control system as required.125mm dia

6

-

-

... More
DUCTING, GRILLS, DIFFUSER AND INSULATION

-

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

1510

-

-

... More
16.12.1.2 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

310

-

-

... More
16.12.1.3 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular dueling as per IS 655-2006

20

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major & Minor OT's, CT/MRI, Bunker, Cath Lab etc.Thickness 0.80 mm Al. Sheet ducting

50

-

-

... More
SITC of below specified Factory Fabricated Aluminium ducting for clean rooms such as major & Minor OT's, CT/MRI, Bunker, Cath Lab etc.brThickness 1.00 mm Al. Sheet ducting;

10

-

-

... More
Supplying and Fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

4.5

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

2.5

-

-

... More
16.17 : Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.

20

-

-

... More
16.18 : Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.

27

-

-

... More
Supply installing, testing and commissioning of perforated aluminium grille for return with VCD and 10 Micron Filter in OT

12

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification.300 mm dia

100

-

-

... More
Supply, Fabrication, installation and testing of folloeing size semi rigid insulated flexible duct, complete with connecting rings, duct supports etc. as per standards and specification. 350 mm dia

10

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 300X300X350H

1

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizes 350X350X400H

10

-

-

... More
SITC of following Insulated Plenum Box made of 22g G.I & Spigot & Butterfly Dampers with necessary threaded rods for supporting for the following sizesbr450X450X400H

135

-

-

... More
SITC of Factory made fresh air dampers with louvers and control lever, filter etc as required. (as per drawing)

11

-

-

... More
SITC of Factory made fresh air dampers having 20 micron filter with louvers and control lever. (for OT as per drawing)

1

-

-

... More
16.13 : Supply, Insulation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper

15

-

-

... More
16.20.1 : Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper

8

-

-

... More
16.20.2 : Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator

8

-

-

... More
Supply & fixing of 19 mm thick Class O nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 45-55kg/m3. Moisture Diffusion Resistance Factor or ‘μ’ value of the base insulation material shall be minimum 10,000, thermal conductivity shall be 0.033 W/mk. R value of the insulation material shall comply with the ECBC + building standards

1900

-

-

... More
"Acoustic insulation:brSupply & fixing of 10 mm thick Class 1 acoustic nitrile rubber insulation with antimicrobial property with adhesive as per the recommendation of the manufacturer with density 140- 180kg/m3

325

-

-

... More
VENTILATION SYSTEM

-

-

-

... More
supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and flexible connection to connect with ducting / plenum-4000 CFM.

1

-

-

... More
supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and flexible connection to connect with ducting / plenum-2500 CFM.

1

-

-

... More
supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and flexible connection to connect with ducting / plenum-2000 cfm.

4

-

-

... More
supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor(Minimum IE 3 Efficiency) and flexible connection to connect with ducting / plenum-1500 CFM.

4

-

-

... More
Axial Fans - for Toilet, Plant room exhaust & Fresh Air:brSupply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with birdscreen Motor efficency , IE 3 : 1000 cfm Exhaust blower

6

-

-

... More
supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and flexible connection to connect with ducting / plenum-750 CFM.

1

-

-

... More
supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and flexible connection to connect with ducting / plenum-600 CFM exhaust blower with Hepa filter [Isolation rooms].

2

-

-

... More
supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, single motor and flexible connection to connect with ducting / plenum-600 CFM exhaust blower with Hepa filter [Isolation rooms].

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 350 cfm Exhaust Blower

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 300 cfm Exhaust Blower

3

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 250 cfm Exhaust Blower.

2

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 200 cfm Exhaust Blower.

1

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen - 150 cfm Exhaust blower

5

-

-

... More
Inline Fans - for Toilet, Plant room exhaust & Fresh Air: Supply, installation, testing and commissioning Direct driven axial flow fans suitable for mounting on wall or duct in standard galvanized/ powder coated steel construction with required rating, static, single motor and flexible connection to connect with ducting / plenum, louvers with bird screen 100 cfm Exhaust blower.

5

-

-

... More
16.12.1.1 : Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006

950

-

-

... More
Supply, Fabrication, installation and testing of the flexible ducting, complete with connecting rings, duct supports, Plenum etc as per standards and specification Size: 100mm dia.

400

-

-

... More
16.15 : Suppluying and Fixing of powder costed extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

1.8

-

-

... More
Supply and fix the following grilles and diffusers as per specifications. Machine made, powder coated, supply and return air grilles and diffusers.SIZE :150 X 150 MM Exhaust Grill

400

-

-

... More
ADDITIONAL WORKS

-

-

-

... More
Automatic type Chemical dosing system, for condenser water piping system(contious treatment) as per specification and drawing.brTotal package of flushing, chemical pre-cleaning, passivation and treatment with chemicals etc. with necessary permanently installed equipment's and its controls. This package includes initial analysing of make up water sample. Then programming methods and duration. Accordingly, supply, install, test commission and maintain for a specified period with dosing pumps , tanks, water meters corrosion coupon tanks, valves with required chemicals and its micro-processor based controller with program etc. as per specification. Maintaining the clean piping system without corrosion, scale or micro-biological activity for an optimum operational efficiency and handing over the entire system in a healthy condition at the end of the contract which is the suppliers responsibility.Cost for supply of chemicals required for one month of passivation to be considered."

1

-

-

... More
Initial Chemical treatment , for chilled water piping system with necessary temporarily installed equipment's - one time flushing, chemical pre-cleaning passivation with suitable chemicals. to make chilled water free of corrosion, scale or micro-biological activity for an optimum operational efficiency and handing over the entire system in a healthy condition at the end of the contract which is the suppliers responsibility

1

-

-

... More
UNDER DECK INSULATION - FOR ICU, OPERATION THEATRE, MRI, CT, ISOLATION ROOMS: Supply & fixing of 9 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3"

120

-

-

... More
Roof(inside) insulation for exposed slabs/walls: brSupply & fixing of 12 mm thick class O nitrile rubber insulation with adhesive as per the recommendation of the manufacture with density 45-55kg/m3

100

-

-

... More
BUILDING MANAGEMENT SYSTEM

-

-

-

... More
Master BMS Operating Station with minimum configration of Intel Xeon Quad-Core 2.4GHz or higher/ 8 GB RAM/ 256 GB SSD,HDD: 1TB,NIC: Min 2 Nos. of 1 Gb Onboard NIC / I/O Ports: 4-USB 2.0 & RJ-45/Orginal OS: Windows 64 bit (As required )/ With 32 Inch LED monitor with Native Resolution--1920 x 1080, HDMI original Antivirus and MS office.

1

-

-

... More
Colour LaserJet Printers

1

-

-

... More
Integrated Building Management System Software for monitoring & controlling the utilities as mentioned in the I-O Summary, with graphics, trend ,The communication protocol shall be on BACnet and Modbus. Software should have 2 concurrent user licence for login over the LAN / WAN. Alarms shall be sent as SMS. SIM Card shall be provided by the Owner Software shall be of latest version , capable of connecting any additional IO Points in future , should have graphical display for the monitor and control

1

-

-

... More
DDC controller stations shall compose of one or more independent, standalone, multitasking, multi user, real time digital control processors. The communication protocol shall be Native BACnet / MSTP .DDC Main IP controllers which connects on LAN shall be with a base of 24 input and outputs which can be expanded up to 256 I/Os by using expansion modules comply to BACnet 135-2010 protocol revision. It shall support one BACnet IP network and 3 independent RS485 interface MSTP channels. Controllers should have 32 bit microprocessor, battery backup, real time clock. Controllers shall have capabality for connecting to the Portable Operators Terminal. Minimum Certifications shall be CE, BTL revision 9, UL 916 and FCC Part 15, Subpart B, Class A.Controller size and the number of controllers shall be sufficient to fully meet the specifications and I/O schedule. All DDC controllers shall be mounted in on IP54 panel, provided with hinged doors with toughened borosilent glass, with locking facility complete with all wiring and accessories complete. DDC panels that will be mounted on Terrace or any outdoor location shall be IP65 rated. Canopy , Floor Mounting stand shall be provided wherever required.DDC for Chiller Plant.

1

-

-

... More
DDC controller stations shall compose of one or more independent, standalone, multitasking, multi user, real time digital control processors. The communication protocol shall be Native BACnet / MSTP .DDC Main IP controllers which connects on LAN shall be with a base of 24 input and outputs which can be expanded up to 256 I/Os by using expansion modules comply to BACnet 135-2010 protocol revision. It shall support one BACnet IP network and 3 independent RS485 interface MSTP channels. Controllers should have 32 bit microprocessor, battery backup, real time clock. Controllers shall have capabality for connecting to the Portable Operators Terminal. Minimum Certifications shall be CE, BTL revision 9, UL 916 and FCC Part 15, Subpart B, Class A.Controller size and the number of controllers shall be sufficient to fully meet the specifications and I/O schedule. All DDC controllers shall be mounted in on IP54 panel, provided with hinged doors with toughened borosilent glass, with locking facility complete with all wiring and accessories complete. DDC panels that will be mounted on Terrace or any outdoor location shall be IP65 rated. Canopy , Floor Mounting stand shall be provided wherever required.DDC for Lower Ground Floor AHU.

1

-

-

... More
DDC controller stations shall compose of one or more independent, standalone, multitasking, multi user, real time digital control processors. The communication protocol shall be Native BACnet / MSTP .DDC Main IP controllers which connects on LAN shall be with a base of 24 input and outputs which can be expanded up to 256 I/Os by using expansion modules comply to BACnet 135-2010 protocol revision. It shall support one BACnet IP network and 3 independent RS485 interface MSTP channels. Controllers should have 32 bit microprocessor, battery backup, real time clock. Controllers shall have capabality for connecting to the Portable Operators Terminal. Minimum Certifications shall be CE, BTL revision 9, UL 916 and FCC Part 15, Subpart B, Class A.Controller size and the number of controllers shall be sufficient to fully meet the specifications and I/O schedule. All DDC controllers shall be mounted in on IP54 panel, provided with hinged doors with toughened borosilent glass, with locking facility complete with all wiring and accessories complete. DDC panels that will be mounted on Terrace or any outdoor location shall be IP65 rated. Canopy , Floor Mounting stand shall be provided wherever required.DDC for Ground Floor AHU.

1

-

-

... More
DDC controller stations shall compose of one or more independent,standalone, multitasking, multi user, real time digital control processors.The communication protocol shall be Native BACnet / MSTP.DDC Main IP controllers which connects on LAN shall be with a base of 24 input and outputs which can be expanded up to 256 I/Os by using expansion modules comply to BACnet 135-2010 protocol revision. It shall support one BACnet IP network and 3 independent RS485 interface MSTP channels. Controllers should have 32 bit microprocessor, battery backup, real time clock. Controllers shall have capabality for connecting to the Portable Operators Terminal. Minimum Certifications shall be CE, BTL revision 9, UL 916 and FCC Part 15, Subpart B, Class A.Controller size and the number of controllers shall be sufficient to fully meet the specifications and I/O schedule.All DDC controllers shall be mounted in on IP54 panel, provided with hinged doors with toughened borosilent glass, with locking facility complete with all wiring and accessories complete. DDC panels that will be mounted on Terrace or any outdoor location shall be IP65 rated. Canopy , Floor Mounting stand shall be provided wherever required.DDC for First Floor AHU

1

-

-

... More
DDC controller stations shall compose of one or more independent, standalone, multitasking, multi user, real time digital control processors. The communication protocol shall be Native BACnet / MSTP.DDC Main IP controllers which connects on LAN shall be with a base of 24 input and outputs which can be expanded up to 256 I/Os by using expansion modules comply to BACnet 135-2010 protocol revision. It shall support one BACnet IP network and 3 independent RS485 interface MSTP channels. Controllers should have 32 bit microprocessor, battery backup, real time clock. Controllers shall have capabality for connecting to the Portable Operators Terminal. Minimum Certifications shall be CE, BTL revision 9, UL 916 and FCC Part 15, Subpart B, Class A.Controller size and the number of controllers shall be sufficient to fully meet the specifications and I/O schedule.All DDC controllers shall be mounted in on IP54 panel, provided with hinged doors with toughened borosilent glass, with locking facility complete with all wiring and accessories complete. DDC panels that will be mounted on Terrace or any outdoor location shall be IP65 rated. Canopy , Floor Mounting stand shall be provided wherever required.DDC for Second Floor AHU.

1

-

-

... More
DDC controller stations shall compose of one or more independent, standalone, multitasking, multi user, real time digital control processors. The communication protocol shall be Native BACnet / MSTP.DDC Main IP controllers which connects on LAN shall be with a base of 24 input and outputs which can be expanded up to 256 I/Os by using expansion modules comply to BACnet 135-2010 protocol revision. It shall support one BACnet IP network and 3 independent RS485 interface MSTP channels. Controllers should have 32 bit microprocessor, battery backup, real time clock. Controllers shall have capabality for connecting to the Portable Operators Terminal. Minimum Certifications shall be CE, BTL revision 9, UL 916 and FCC Part 15, Subpart B, Class A.Controller size and the number of controllers shall be sufficient to fully meet the specifications and I/O schedule.All DDC controllers shall be mounted in on IP54 panel,provided with hinged doors with toughened borosilent glass, with locking facility complete with all wiring and accessories complete. DDC panels that will be mounted on Terrace or any outdoor location shall be IP65 rated. Canopy , Floor Mounting stand shall be provided wherever required.DDC for Third Floor AHU.

1

-

-

... More
DDC controller stations shall compose of one or more independent, standalone, multitasking, multi user, real time digital control processors.The communication protocol shall be Native BACnet / MSTP.DDC Main IP controllers which connects on LAN shall be with a base of 24 input and outputs which can be expanded up to 256 I/Os by using expansion modules comply to BACnet 135-2010 protocol revision. It shall support one BACnet IP network and 3 independent RS485 interface MSTP channels. Controllers should have 32 bit microprocessor, battery backup, real time clock. Controllers shall have capabality for connecting to the Portable Operators Terminal. Minimum Certifications shall be CE, BTL revision 9, UL 916 and FCC Part 15, Subpart B, Class A.Controller size and the number of controllers shall be sufficient to fully meet the specifications and I/O schedule.All DDC controllers shall be mounted in on IP54 panel, provided with hinged doors with toughened borosilent glass, with locking facility complete with all wiring and accessories complete. DDC panels that will be mounted on Terrace or any outdoor location shall be IP65 rated.Canopy,Floor Mounting stand shall be provided wherever required.DDC for Fourth Floor AHU

1

-

-

... More
Gateway and Open Protocol Software/ Hardware compatible to industrial standard protocols like Modbus RTU , Modbus over Ethernet, BACNet-MSTP, BACNet-IP, LON, M-Bus for the following third party system coming on these universal protocols. (Refer IO Summary for number of devices and datapoints and equal number of converters shall be considered per system.). The unit shall be supplied with wall mounted enclosures including all wiring and accessories complete.The hardware shall be mounted in the DDC panel enclosure only-Chiller

1

-

-

... More
Gateway and Open Protocol Software/ Hardware compatible to industrial standard protocols like Modbus RTU , Modbus over Ethernet, BACNet-MSTP, BACNet-IP, LON, M-Bus for the following third party system coming on these universal protocols. (Refer IO Summary for number of devices and datapoints and equal number of converters shall be considered per system.). The unit shall be supplied with wall mounted enclosures including all wiring and accessories complete.The hardware shall be mounted in the DDC panel enclosure only-VFD of Secondary Pumps.

1

-

-

... More
Outside Air Temperature/ Humidity Sensors For measuring Outside Ambient Temp/ Humidity with 2% Accuracy, having sensing element type 20,000 , NTC Thermistor, ±0.2 C, range 0 to 100% RH, .±0.05% RH/ °C.

1

-

-

... More
Water Immersion Type Temperature Sensors,Range 0 0C - 20 0C , 2% accuracy, with thermowell

4

-

-

... More
Duct type Temperature Sensors , with Sensor Accuracy 20,000 , NTC Thermistor, ±0.2 C, Operating Temperature 0 - 50°C (32 - 122°F)

20

-

-

... More
Room Temperature + RH Sensors with LCD display with ±0.2 C, Operating Temperature 0 - 50°C (32 - 122°F)

5

-

-

... More
Room Relative Humidity Sensors, with 3% accuracy, 0 to 100% RH range, 4-20ma output.

18

-

-

... More
Room or Return Air Quality - CO2 Sensors

1

-

-

... More
Water DP Switch across supply and return headers, with Copper tube to monitor pump status (Working Pressure 4 kg/sq.cm.)

6

-

-

... More
Air DP Switch Across air handling units & TFA units for indicating filter status with switch tollerence of ±15%, operating pressure of 1.45 PSI (10 kPa) for all pressure ranges,Medium and ambient temperaturebr-20°C to 60°C (-4°F to 140°F),Diaphragm Material Silicone, tempered at 200°C, electrical rating of Max. 1.0A (0.4A) / 250 VAC, 50/60 Hz.

48

-

-

... More
Pressure Transmitters for Chilled water supply header pressure sensor - (Pressure Range 0-10 kg./sq.cm.).

2

-

-

... More
Liquid level switches indicating low/ high water level in water tanks and sumps, hot water tanks etc

3

-

-

... More
2 Core 1.0 SQ. MM, Armoured ATC conductor multistranded, screened ,shielded, PVC FRLS cable for field devices

3800

-

-

... More
4 Core 1.0 SQ. MM, Armoured ATC conductor multistranded, screened ,shielded, PVC FRLS cable for field devices.

3300

-

-

... More
2 Core 1.5 SQ. MM, Armoured ABC conductor multistranded, PVC FRLS cable for integration with starter panel and for status monitoring

2100

-

-

... More
4 Core 1.5 SQ. MM, Armoured ABC conductor multistranded, PVC FRLS cable for integration with starter panel and for status monitoring.

2700

-

-

... More
3 Core 1.5 SQ. MM, Armoured ABC conductor multistranded, PVC FRLS cable for power.

1200

-

-

... More
2 Core X 1.5 sqmm, ATC twisted, shielded , armored Cables for DDC communication.

1100

-

-

... More
Supply and installation of MS POWDER COATED (GREY COLOUR) Raceways of 2mm thickness with cover in ceiling and shafts etc with complete MS supports fabricated per site requirements and two (2) coat of enamel paint over a coat of primer.300 x 40 x 2 mm thick

50

-

-

... More
cover in ceiling and shafts etc with complete MS supports fabricated per site requirements and two (2) coat of enamel paint over a coat of primer.200 x 40 x 2 mm thick.

100

-

-

... More
Supply and installation of MS POWDER COATED (GREY COLOUR) Raceways of 2mm thickness with cover in ceiling and shafts etc with complete MS supports fabricated per site requirements and two (2) coat of enamel paint over a coat of primer.150 x 40 x 2 mm thick.

100

-

-

... More
SUBHEAD 5 - FIRE FIGHTING WORKS Fire Pump_Control Panel and Pump room Pipe

-

-

-

... More
MAIN PUMP - Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class- "F " insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 LPM at 88 metre Head.

1

-

-

... More
SPRINKLER PUMP - Supplying, installation, testing and commissioning of Electric driven sprinkler Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class- "F " insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 LPM at 88 metre Head.

1

-

-

... More
DIESEL PUMP - Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator,diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2280 LPM at 88 metre head.

1

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.180 lpm at 88 m Head. Motor rating shall be minimum IE 3.

2

-

-

... More
MOTOR CONTROL PANEL - Fabrication, supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated Common Control Panels for Main Fire Pumps & Jockey Pumps, made out of 14 SWG thick CRCA sheet fully compartmentalised complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates (top entry) made out of 3mm thick sheet steel including all components as shown in the schematic drawing. All opening parts of the panel shall be sealable. The panel shall be IP: 54 protection, complete with Main Isolator, Bus Bar Chamber, Volt Meter, Ammeter, Individual Star- Dealt Starters for Main Pumps, DOL Starter for Jockey Pump, Contactors, Auxiliary Contacts, Timers for automatic operation and to avoid freequent re-starts, Indicating Lamps, Fuses, Auto / Manual Selector Switches for all Fire Pumps, Manual On / Off Buttons for Jockey Pump & Manual On Buttons for Main Pumps, all internal wiring etc. The price for Control Panel shall be inclusive of, Control Cabling, in Steel Conduits, for automatic starting of Main Pumps & Automatic start and stop for Jockey Pump and Earthing of the Panel, all as per Technical Specifications, Schematic Drawing, Prevailing Rules, Standards, Requirement and Site Conditions. The Panel shall be to the approval of Kerala State Electrical Inspectorate. "Main Fire Pump - 1 No. Sprinkler Pump - 1 No. Jockey Pump - 2 Nos. "Incomer - 320A, FP, Switch Disconnector (Trip Free Switch) 1-No. 320A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage, current, Frequency, Power Factor, kW, kVA, Old energy, On hours, site selectable kWh/kVAh Class B + C / Class 1 + 2 Surge arrestor device with necessary MCCB for protection of same - 1 Set. RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoing a) 200A, TP+NL, Switch Disconnector + Star delta starter with all accessories Without overload relays / protection - 2 Set. b) 32A, TP+NL, MCCB Isolator + DOL Starter with all accessories with overload realy and single phase preventor - 3 Set (1 spare).

1

-

-

... More
Supply, erection, commissioning of additional length of Exhaust Pipes with long radius bend from silencer with necessary clamps, fixtures, civil works and thermal insulation with 50 mm thick glass wool and with 1.0 mm thick aluminium sheet cladding of following adequate size including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. The horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other acessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for istallation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building withing 10m radius of the exhaust.

30

-

-

... More
Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 250 mm dia.

25

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 200mm

16

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 150mm

66

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 100mm

15

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 80mm

6

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 65mm

6

-

-

... More
Providing, laying, testing & commissioning of "C" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 25mm

15

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 200 mm dia.

4

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia.

7

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia.

1

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 80mm

20

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 16 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 65 mm dia

2

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with required companion flanges nuts, bolts etc. complete.150mm.

4

-

-

... More
Providing, installing and commissioning C.I.flanged "Y" type Strainer with SS mesh, suitable flanges, nuts, bolts, gaskets etc. complete. Dia - 200mm

2

-

-

... More
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12, Flanged to BS5163, PN16, UL Listed & FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete. Dia - 200mm

2

-

-

... More
Supply, installation, testing and commissioning of Heavy Duty Neoprene Expansion Joints / Flexible Connectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories.Dia - 200mm

3

-

-

... More
Supply, installation, testing and commissioning of Heavy Duty Neoprene Expansion Joints / Flexible Connectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories.Dia - 150mm.

3

-

-

... More
Supply, installation, testing and commissioning of Heavy Duty Neoprene Expansion Joints / Flexible Connectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories.Dia - 80mm.

3

-

-

... More
Supply, installation, testing and commissioning of Heavy Duty Neoprene Expansion Joints / Flexible Connectors, PN:16, with Spilt Retainer Rings and Control Units, drilled to BS 10 Table E including all other necessary fixing accessories.Dia - 65mm

2

-

-

... More
Hydrant System_Fire Pipes Valves and Accessories

-

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 150mm

550

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 200 mm dia.

30

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 100mm

310

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 80mm

350

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 65mm

220

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 50mm

400

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 40mm

150

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 32mm

300

-

-

... More
Providing, laying, testing & commissioning of "C " class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :Dia - 25mm

1100

-

-

... More
Providing laying, testing & commissioning of "C" class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm. Dia.

415

-

-

... More
Providing laying, testing & commissioning of "C " class heavy duty MS Pipe conforming to IS1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anti corrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.100 mm dia pipe.

120

-

-

... More
Providing laying, testing & commissioning of "C " class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anti corrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.80 mm dia.

45

-

-

... More
Providing and fixing Ductile Iron Gate Valve, Rising Spindle, OS & Y Type, Body: ASTM A536, 65-45-12, Flanged to BS5163, PN16, UL Listed / FM Approved with Tamper / Supervisory Switches and with required flanges, rubber insertions, bolts, nuts, Washers etc. complete.200mm.

2

-

-

... More
Providing, fixing, testing and commissioning of Non Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 with nuts, bolts etc. complete. 150mm.

4

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 150mm

13

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 100mm

2

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 80mm

13

-

-

... More
Providing, fixing, testing and commissioning of Butterfly Valve, Wafer Type, Working Pressure 16 Bar, Gear / Lever Operated (as per manufacturer) confirming to ASTM A-536, grade 65-45-12, with Micro Switch and Position Indicator UL Listed & FM Approved, with required Matching Flanges, nuts, bolts etc. Dia - 65mm

2

-

-

... More
Providing, fixing, testing and commissioning of Ball Valve, PN-16 Forged Brass & Nickel / Chrome Plated, conforming to IS: 9890, UL Listed and FM approved with Screwed Female Ends to BS:21, and with non-corrosive handle / lever, including necessary accessories and connections. Dia - 50mm

2

-

-

... More
Providing, fixing, testing and commissioning of Ball Valve, PN-16 Forged Brass & Nickel / Chrome Plated, conforming to IS: 9890, UL Listed and FM approved with Screwed Female Ends to BS:21, and with non-corrosive handle / lever, including necessary accessories and connections. Dia - 25mm

25

-

-

... More
Supply, installation, testing and commissioning of Pressure Switches with pressure rating 4 to 14 Bar with a differential of 0.2 to 1.6 Bar (however; should be suitable for Fire Pumps) and with 1/4 BSP (F) inlet connection and screwed cable entry for fixing cable gland. It shall also be complete with Stainless Steel Isolation Cock, Nipples, tail, connecting pipes etc.

5

-

-

... More
Supply, installation, testing and commissioning of 4" dia. Bourdon Type Pressure Gauge, with ISI Mark or of equivalent International Standards. Weather / Water Proof Type, Pressure Range: 0 to 16 Bar, with Stainless Steel Shut off Cock, Syphone Pipe, Snubber etc.

1

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

1

-

-

... More
Supply, installation, testing and commissioning of Fire Hydrant Valve, bearing to ISI:5290 Type-A mark, Stainless Steel-304 body with 63mm. oblique instantaneous single outlet, 75mm. N.B. flanged inlet, Stainless Steel -304 spindle, complete with PVC blank cap, G.I. chain etc.

34

-

-

... More
Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided /rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm dia isolating valve and all other necessary fixing accessories including Fabrication and Erection of M.S. Support, as per requirement, for Fixing the Fire Hose Reel Set.

34

-

-

... More
Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fiber. conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg/Cm2 and Burst Pressure 38 Kg/Cm2. The Fire Hose shall be with IS: 636 Type-A marking and 63mm. dia.x15Mtr.long with pair of 63mm. male and female instantaneous couplings, Stainless steel-304, having IS: 903 mark and duly S. S. wire wounded. The hose shall be rolled and hung to suitable M. S. support in the Fire Station.

68

-

-

... More
Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304, short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark.

34

-

-

... More
Supplying, installing and commissioning of fire brigade inlet, inlet connection of 4 way with 4 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main as well as to Fire water tank. Qouted rate shall be included with M.S. cabinet (painted - inside and outside) of suitable size with mounting supports etc. complete.

2

-

-

... More
Supply, installation, testing and commissioning of Fire Brigade Inlet Breeching, C.I. body, having 3 Gunmetal, 63mm. male instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 3 nos. of rubber blank caps and G.I. chains.

1

-

-

... More
Supply, installation, testing and commissioning of Fire Brigade Draw Off Outlet C.I. body, having 3 Gunmetal, 63mm. female instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 3 nos. of rubber blank caps and G.I. chains.

1

-

-

... More
Supply and fix at site in position Weather proof Fire Hose Cabinet, wall / pole mounting type, 30" x 24" x 10" size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement.

11

-

-

... More
Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30" x 24" x 10" size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement.

23

-

-

... More
Providing and fixing sight glass assembly of brass body and brass ball with chrome plated, steel handle, PN16 or above, UL Listed & FM Approved. Test and drain valve shall be with compact 3 position ball valves with drain orifice having K-factor 5.6 and a sight glass. 3 positions consist of OFF, TEST and DRAIN. Test and drain valves shall be provided for test as well as express drain functions in wet sprinkler systems with grooved end connection ends. The Test and Drain Valve shall be in Brass ASTM B584 material of construction. These have integral tamper resistant sight glass.

14

-

-

... More
Supply, installation, testing and commissioning of Air Release Valve Gunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including isolation valve and necessary accessories and connections.

6

-

-

... More
Supply, installation,testing and commissioning of orifice plates; with the following specification : made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

17

-

-

... More
Supply, installation,testing and commissioning of orifice plates; with the following specification 25 mm dia Orifice plate made out of 8 mm thick stainless steel plate ( in tee off to fire hose reel) for pipe to reduce pressure upto 3.5 Kg/sqcm complete in all respects

15

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories:Pendant sprinkler.

530

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories: Upright sprinkler.

300

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories:Horizontal side wall sprinkler.

10

-

-

... More
Providing, fixing, testing and commissioning of Standard Coverage, Standard Response Automatic Fire Sprinkler, K- Factor: 5.6 (80 Metric) or equal to the approval of system consultant / engineer - in - charge, with necessary accessories and fittings. Pendant type - 79 Deg.C (For kitchen)

12

-

-

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required: 150mm dia

1

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 16 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System., all as per Technical Specifications. The control cabling from flow switches to concerned Module shall be measured with proposed Fire Alarm System. Dia - 150mm

23

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 16 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System., all as per Technical Specifications. The control cabling from flow switches to concerned Module shall be measured with proposed Fire Alarm System. 65 mm dia

2

-

-

... More
Providing, Fixing, testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 20 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System., all as per Technical Specifications. The control cabling from flow switches to concerned Module shall be measured with proposed Fire Alarm System. Dia - 50mm

1

-

-

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1200mm.

530

-

-

... More
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

530

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

11

-

-

... More
Supplying and Fixing 25 mm dia Orifice plate made out of 8 mm thick stainless steel plate ( in tee off to fire hose reel) for pipe to reduce pressure upto 3.5 Kg/sqcm complete in all respects

8

-

-

... More
Intelligent Addressable Fire Alarm System

-

-

-

... More
Supply, install, test and commission Intelligent Addressable Fire Alarm Control Panel (MCP) as per the technical specification and not limited to having Visual Display Unit (VDU) preferably 640 character LCD display with Battery Back up for 24 hours for normal operation and 1 hours on alarm condition. The control panel, battery charger etc, shall be UL listed approved. The panel shall work in a flash scan protocol and shall be networked together and capable of networking with other compatible panels. The Panel shall have 10 Loop Capacity and shall be as per Technical Specifications.

1

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Multi Sensor Detectors. The detectors shall have multiple sensitivity (adjustable at site) levels, programmable for timed automatic sensitivity selection complete with Standard Base, junction box and other accessories as required. Detectors shall be UL listed and FM Approved.

408

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Heat Detector and with rate of rise of temperature feature, programmable for timed automatic sensitivity selection with Standard Base, junction box and other accessories. Detectors shall be UL listed.

24

-

-

... More
Supply, installation, testing and commissioning of Response indicator for all detectors located above false ceiling.

173

-

-

... More
Providing, fixing test and commission Intelligent Addressable Manual Call Station Point with addressable module that monitors and reports contact status, etc

24

-

-

... More
Providing, fixing, test and commission Conventional Type Horn/Strobe rated at 82 dB @3Mtr. for audible annunciation and 75Candela flashing at 1Hz. for visual indication.

26

-

-

... More
Providing, fixing, testing and commission Intelligent Addressable Input / Monitor Module, for interface with Flow Switches, Fire Pumps, Supervisory Switches, Alarm Valve, Water Tank Level etc.

25

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Control Module, for interface with Fire Alarm Annunciating System, Lift Panels, Public Address System etc.

59

-

-

... More
Providing, fixing,, test and commission Intelligent Addressable Relay Module, for interface with AHUs, Ventilation System, Smoke Management System, LPG System, Power Distribution etc. (This quantity shall be tentative / approximate only, shall change as per final design of the other systems and final requirement)

15

-

-

... More
Providing, fixing, test and commission Intelligent Addressable Fault Isolator Module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected, all as per technical specifications.

38

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm

150

-

-

... More
Supply, laying, testing and commissioning o 2Core x 1.5 mm2 FRLS Armoured Cables with Red Colour / Finish.

2760

-

-

... More
Supply, installation and testing & commissioning of 24V 5amps Power Supply unit with 7AH Battery The Panel should have contact to give feedback to main Fire panel about the power avialablility from the unit.

25

-

-

... More
4.6.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.225 mm width X 50 mm depth X 1.6 mm thickness

120

-

-

... More
4.7.3 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.225 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
Fire Extinguishers

-

-

-

... More
Clean Agent Modular Type Ceiling mounted Fire Extinguisher 5 Kgs Capacity made of Mild Steel Body of 1.6 mm thickness with pressure gauge, refillable device and safety release device CE Certified Brass valve suitable for A, B and C Classes of Fire complete with Charge of Clean agent (Gas) is also known as HFC Blend A, It is a blend of Hydro Fluoro carbon and organic detossificant essence P26. The sprinkler body will comprise of temperature sensitive quartsoid bulb of temperature rating of 680. The cylinder will be supplied with a proper mounting arrangement to mount it on the ceiling. The Extinguisher shall be externally epoxy powder coated as per IS: 5 Color Shade No. 538 (For Server room) 5 Kgs

1

-

-

... More
ABC powder type fire extinguisher with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc. complete, confirming to IS:15683. 6 Kgs.

34

-

-

... More
Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.Co2 type Fire Extinguisher, made from brand new seamless Steel cylinder, as per IS: 7285 and CCE approval, fitted with Discharge hose and horn and Wheel type valve with initial Charge and mounted on Rubber Wheels / wall mounted brackets as per IS: 16018 specification, bearing ISI Mark. 4.5 Kgs

12

-

-

... More
Fire Bucket in 9 Ltr. Capacity, made of MS sheet in round bottom with side handle painted with Red in colour & mentioned "FIRE"; over it. 4 Nos. per set with one Fabricated M. S. Stand

2

-

-

... More
Mechanical Foam Fire Extinguisher, 9 Litre's capacity Fire Extinguishers pressurised by Nitrogen Gas fitted with brass valve, plastic syphon tube and discharge hose with Nozzle and Pressure Gauge to indicate pressure inside. Extinguisher is Phosphated and Epoxy powder coated internally and externally as per IS: 5 Shade No. 538 complete with wall brackets. The Extinguisher is manufactured as per IS 15683-2018 bearing ISI Mark.

2

-

-

... More
Fire Signages

-

-

-

... More
Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.25cm height letters in red with white back ground.The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points and shall be as per IS code 9457:2005, IS 12349, IS 12407.

17

-

-

... More
Floor identification signage ( ie, GROUND FLOOR, FIRST FLOOR, etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 cm with contrasting colour from back ground.Size shall be 15cm x 30cm and shall be as per IS code 9457:2005, IS 12349, IS 12407.

17

-

-

... More
Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) on every floor, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm. and shall be as per IS code 9457:2005, IS 12349, IS 12407

44

-

-

... More
Providing and fixing in position the signage " FIRE ORDER" on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2 " x 3 ".

8

-

-

... More
Providing and fixing in position the signages " Fire Hydrant Chamber" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2 " x 3 ".

22

-

-

... More
Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size: 300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red / Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum), with 4 Hr. Battery Backup. Single Side Display

16

-

-

... More
Supply, installation, testing and commissioning of Fire Exit Light, Laser type, with High Glow LED, size: 300x 178 x 32 mm. or 390 x190 x 60mm, Ceiling Mounting type with hanging clamps, on/off switch, Red / Green Colour option with minimum of 25 Mtr. viewing distance, power consumption: 5.0 Watt per face (maximum), with 4 Hr. Battery Backup. "Double Side Display

8

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
FIRE SEALANT for Fire and ELV Shafts - Supply and Fixing of load bearing Fire stop mortar system with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, for openings in floors or slabs after passing service lines. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a VOC content of approx. 1 g/l as per LEED 2009. Firestop installation should be done by trained applicators (HAFSC) and in accordance with manufacturer's guidelines by providing 10mm dia rebars at 200mm c/c both ways with chemical anchoring along the length and breadh of the shaft and provide 2 layers of chicken mesh etc. The mortar shall be applied with a minimum thickness of 65 mm & having load bearing capacity of 200kg/sqm. Proper engineering judgement needs to be submitted through the manufacturer. Complete installation report through Software CFS DM shall also be submitted for inspection purpose.

25

-

-

... More
Providing 150mm. Puddle Flange for Roof Level (Terrace) Fire Water Tank, Fabricated, Hot Dip Galvanised and Fix in Position, all as Per Tender Drawings and Technical Specifications.

1

-

-

... More
TALK-BACK SYSTEM

-

-

-

... More
Supply, installation, testing & commisioning of automatic control console of 8 zones micro process based complete with floor to floor announcing and talk back facilities with the following features and made functional: (a) Feather type key pads to select the zones. (b) Moulded plastic attractive enclosure. (c )Backlight Liquid Crystal Display(LCD) (d) User friendly interactive display. (e) Announcement selector - PH Switch. (f) Listen selector switch. (g) All Call switch to select all zones simultaneously for announcement (h) Zones Call Display On the LCD With Audio Alarm and with 120 W amplifier.

1

-

-

... More
Supply, installation, testing & commissioning of 19" Rack 400/500mm depth, 6U high rack assembly (wall/surface mountable type) made of MS equivalent to euro rack system, with side and rear panels made of 14 swg powder coated sheet steel front transparent persplex door and with rails, rollers & bearings. Side panels shall be ventilated type.The rack shall be powder coated of approved color.

1

-

-

... More
Supply, installation, testing and commisioning of Public Address speaker with talk back facility 6 Watts with L M T and call switch, made out of powder coated CRCA sheet, wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting.

16

-

-

... More
Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armored Cables with Green / Blue Colour / Finish, as per Technical Specifications. (Approx. Quantity for Networking)

450

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

250

-

-

... More
SUBHEAD 6 - LIFT WORKS Passenger Cum Bed Lift

-

-

-

... More
26 Passenger cum Bed Lift-Design, fabrication, supply. installation, testing and commissioning of 26 Passenger cum Bed Lift, Gear less with Machine Room, Capacity / Weight 26 Pass (1768 Kg), Speed 1.5 MPS, electric traction type, Stainless steel (Including freight, landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V+/-10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with prerecorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. PMSM traction motor ( having efficiency equivalent to IE3 or better as in IS 12615) of machine room elevator shall be of gearless type and placed inside the machine room complete as per technical specifications. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details- 06 stops, 06 openings and entrance and exit at same side and suitable for travel height of 27 meter approximate. (Shaft Size 2425mm (width) x 3000mm (depth)) with door opening of 1500 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/Code and complete in all respects as per technical specifications. Test reports from NABL accredited testing labs for all constituent compounds shall be produced.

2

-

-

... More
Goods Cum Bed lift

-

-

-

... More
2T Goods cum Bed Lift - Design, fabrication, supply. installation, testing and commissioning of electric traction type, with machine room type , Stainless steel, 2T capacity goods cum bed Hospital elevator (Including freight, landing charges, insurance and all applicable taxes and duties in country of origin and in India etc. except GST) and type suitable for operation on 415 V+/-10%, 3 phase, 50 Hz AC supply, having AC variable voltage and variable frequency micro-processor type traction control, speed of 1 Mtr/sec, electromagnetic brake system, Simplex mode operation, operating panel with luminous buttons, overload warning indicator, battery operated alarm bell, LED type emergency light, intercom suitable for hook up to Purchaser's EPABX, infrared ray sensing door protection for full height, reverse phase relay on controller, fireman's switch at initial landing floor, LCD/LED car positions and direction indication in car and landings. And at all floors with UP/DOWN direction, shaft wiring and lighting with accessories, braille buttons, audio announcement along with pre-recorded message as approved by Engineer-in-Charge, all accessories including Safe Landing Device (SLD), Automatic Rescue Device (ARD) with dry maintenance free sealed batteries and Manual Emergency Rescue Device and all electrical components with wiring from the single point power supply provided at top landing near the elevator door complete as required. The drives of elevator shall meet the requirements of IEEE 519/2014. The traction motor (having efficiency equivalent to IE3 or better as in IS 12615) of machine room elevator shall be of gear less type and placed inside the machine room complete as per technical specifications. Having automatic centre/side opening stainless steel doors, Matt finish stainless steel car enclosure provided with stainless steel handrails on three sides, 2 mm fluted SS flooring as applicable in accordance of following details - 06 stops, 06 openings and entrance, exit at same side and suitable for travel height of 27 meter approximate. (Shaft Size 2500mm (width) x 3000mm (depth)) with door opening of 1500 mm (width) and 2100 mm (height). The equipment should be BMS compatible. All components, fabrication and procedures shall confirm to relevant IS standards/Code and complete in all respects as per technical specifications. Test reports from NABL accredited testing labs for all constituent components shall be produced.

1

-

-

... More
SUBHEAD 7 - EXTRA LOW VOLTAGE SYSTEM LAN NETWORK (FOR ALL SYSTEM)

-

-

-

... More
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT6A Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

40

-

-

... More
Information Outlet RJ 45 - Supply, fixing, fluke testing and commissioning of CAT 6 Information Outlets (Key stone) with Shuttered Faceplate, Single port, white, jack, suitable PVC / GI Modular Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by the Engineer in charge

180

-

-

... More
Information Outlet RG6 - Supply, fixing and commissioning of RG6 Outlet Rg6 Satellite cable Socket with face plate, white, jack, suitable PVC / GI Modular Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

10

-

-

... More
CAT 6A Cable - Supplying and drawing of Category 6A cable consists of 4 pairs of solid insulated copper 23AWG, LSZH, (complying IEEE802.3 AF and IEEE802.3 AT) Fluke testing with reports, labeling, as built drawings, with minimum 10 manufacturer warranty in the existing surface/recessed steel/ PVC conduit as required. as instructed by engineer in charge/consultant

2600

-

-

... More
CAT 6 Cable - Supplying and drawing of Category 6 cable consists of 4 pairs of solid insulated copper 23AWG, LSZH, Fluke testing with reports, labeling, as built drawings, with minimum 10 years manufacturer warranty. as required for complete installation and as instructed by engineer in charge/consultant.

16920

-

-

... More
RG6 Cable - Supplying and drawing of RoHS/EU Compliant RG6 Co-axial cable Compliant less than 13.5 dB loss at 3000 MHz as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

425

-

-

... More
RG11 Cable - Supplying and drawing of RoHS 2011/65/EU Compliant RG11 Co-axial cable less than 10 dB loss at 3000 MHz through wall/tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

100

-

-

... More
OFC Cable - Supplying and drawing of 12 core MM (OM3/4)Outdoor armored Optical Fiber Cable (OFC), LSZH through wall/tray Etc. with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation.

460

-

-

... More
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6A Patch Cable - 2 Meter length etc. of approved make as required for complete installation.

42

-

-

... More
Patch Cable - User Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 2 Meter length etc. of approved make as required for complete installation.

107

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of CAT6A Patch Cable - 1 Meter of approved make as required for complete installation.

43

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of CAT6 Patch Cable - 1 Meter of approved make as required for complete installation.

211

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6A,24 port fully loaded patch panel with rear cable management including crimping / Splicing patching of cable with fluke reports. with all accessories required for complete installation as required as directed by the engineer in charge.

3

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6, 24 port fully loaded patch panel with rear cable management including crimping / Splicing with fluke reports ,patching of cable including all accessories required for complete installation as required as directed by the engineer in charge.

22

-

-

... More
Supply, Installation, Testing and commissioning of 12 port Light Interface Unit (LIU) / Fiber Patch Panel, rack mountable with mounting brackets, loaded with Adaptors, Couplers Multi Mode (MM) pigtails with splicing with all accessories required for complete installation with OTDR Report as required as directed by the engineer in charge.

6

-

-

... More
Supply, Installation, Testing and commissioning of 24 port Light Interface Unit (LIU) / Fiber Patch Panel, rack mountable with mounting brackets, loaded with Adaptors, Couplers Multi Mode (MM) pigtails with splicing with all accessories required for complete installation as required as directed by the engineer in charge.

3

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

6090

-

-

... More
Supply, erection, testing and commissioning of following pair krone Box with mounting frame, enclosure of ISI grade with lockable front cover with all accessories required for fixing the box with all accessories required for complete installation in wall as directed by the Engineer in charge. 300 Pair MDF Krone(150x2) along with necessary patch Cords to connect with PABX system

1

-

-

... More
Supplying and laying of following pair armoured telephone cable through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 20 Pair Telephone Cable

300

-

-

... More
Supplying and laying of following pair armoured telephone cable through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. 10 Pair Telephone Cable

290

-

-

... More
Supply and Installation of 20 Pair MDF Box with Krone and necessary Patch cables to connect with patch panel.

5

-

-

... More
Supply and Installtion of 10 Pair MDF Box with Krone and necessary Jump cables to connect with patch panel

2

-

-

... More
Patch Cable - Hub Side - Supply, fixing, testing and commissioning of Multi Mode Fibre Patch Cable (LC) Duplex - 2 Meter of approved make as required for complete installation.

34

-

-

... More
VOICE-IPPBX

-

-

-

... More
Supply, installation, testing and commissioning of Basic IP user phone with necessary connection as required for complete installation as directed by the engineer in charge.

2

-

-

... More
Surge Protection Device For EPABX: Supply, Installation, Testing and commissioning of SPD with enclosure, the surge protection device shall be suitable to protect telephone lines designed to with stand both lightning current and switching surges. Technology: GD tube, Nominal Voltage: 180 V, Pulsed Current (10/350) Iimp: 1 KA, Nominal Discharge Current (8/20 )/phase In: 5KA, Maximum discharge current: 10 KA,Voltage Protection Level(sym)700V, Response time 1n sec

1

-

-

... More
Supply, Installation, Testing and Commissioning ofIP PBXIP PBX with 100 Analog extensions 10 Ip extension and expandable up to minimum 500 Extensions, 1 ISDN PRI interface, 4 analogue trunk lines, 4 SIP trunk,8 Port IVR Failover Function, Web Interface, Call Dashboard, DISA, IVR, Call Hunt etc. including one Qty each Digital/ IP Operator phone and short key / Direct Station Selection (DSS) Console.Built-In Auto Answer SIP/IP Coverage ISDN PRI over IP Compatibility Voice Mail Integration Paging Announcement Programmable Function Keys Call Waiting, External Paging and should connect with PA System for announcement with all accessories for the complete PABX commissioning as per the instruction from Site Engineer/Consultant.

1

-

-

... More
Supply, installation, testing and commissioning of Basic Analog with necessary connection and telephone RJ11 Patch cord as required for complete installation as directed by the engineer in charge.

50

-

-

... More
CLOSED CIRCUIT TELEVISION (CCTV)

-

-

-

... More
Varifocal Dome -IP network true day/night indoor Dome PAL color Camera with min 1/3" Progressive scan CCD / CMOS - 2MP resolution image sensor, with min one H.264/H265 stream for recording one H265/H264 stream for live viewing. It shall have the capability to deliver two independent video streams and shall be possible to set independent FPS ( 30 fps for H.264/265) Compression selection for each stream with built in 2.8 - 12 mm lens or near, Motorized Vari focal, in indoor dome housing with built in WDR -120dB , PoE, With memory card slot, BLC/3D DNR/HLC also with the capability to add manufacturer power supply unit if required at site and with built in WEB Browser and required wall / ceiling mounting accessories as specified in the Tender Specifications. The cameras should be IP67,IK10,ONVIF, with all mounting accessories as required.

19

-

-

... More
OUTDOOR BULLET -IP network true day/night IP67 rated outdoor Wall / Pole Mount Bullet PAL Colour Camera with min 1/3 Progressive scan CMOS- min 2 MP resolution image sensor, with min one H.264/H265 stream for recording and one H.264/H265 stream for live viewing. It shall have the capability to deliver two independent video streams and shall be possible to set independent FPS (30 fps for H.264) Compression selection for each stream with built in 2.8 - 12 mm lens, Motorized vari focal, auto DC iris lens with built in WDR/D-WDR , HLC /BLC circuitry for varying light levels , Min 30mts IR distance POE connectivity and also with external power supply with built in WEB Browser. , ONVIF, with all mounting accessories as required- Surge protected

10

-

-

... More
Indoor Dome- IP network true day/night indoor Dome PAL color Camera with min 1/3" Progressive scan CMOS - min 2 MP resolution image sensor, with min one H.264/H265 stream for recording and one H.264/H265 stream for live viewing. It shall have the capability to deliver two independent video streams and shall be possible to set independent FPS (30 fps for H.264) Compression selection for each stream with built in 2.8 / 3.6 lens or near as required, in indoor dome housing with built in WDR (120DB)/D-WDR, HLC / BLC circuitry, PoE, also with the capability to add manufacturer power supply unit if required at site and with built in WEB Browser and required wall ceiling mounting accessories as specified in the Tender Specifications, ONVIF , with all mounting accessories as required.

35

-

-

... More
Network Video Recorder with Storage: Supply, installation, testing and commissioning of Channel Network Video Recorder with Recording Storage space server for 30 days, supports 64 channels min 1080P resolution video recording at real time, NVR ONVIF supporting, recording resolution of Min 8 MP, should support dual video HDMI output, H.265, H.264 at real time. Video storage expansion for recording for complete installation with all accessories as required and directed by engineer in charge. Consider the sufficient HDDs for 720p @ 20 FPS for 30 days@ RAID 5 continues recording for all channels. Storage calculation details shall be submitted. N+1 feature for Storage should be considered, N+1 feature should be supported for system-Wireless Mouse to be included for Operation.

1

-

-

... More
LED Display - Supply, installation, testing and commissioning of 40 inch full HD LED display , 24 x 7 with HDMI input Setup including necessary connection, HDMI cable, rating tray ,Plastic trunks etc. as required for complete installation with all accessories as required and directed by engineer in charge.

1

-

-

... More
Supply fixing of CAT 6 RJ45 connector with IP66 rated Box for keeping connection connections or adaptors inside box for cameras/Wifi /or any ceiling mounted equipments.

112

-

-

... More
ACTIVE COMPONENTS

-

-

-

... More
Supply, Installation, Testing and commissioning of Cat - 6, 24 port 10/100/1000 Mbps with 4 SFP uplink, layer 2, Manageable Non-POE, switch with rack mounting brackets, minimum 1 Qty of 10G Uplink, with all accessories required for complete installation . Back Plane should be considered as per bandwidth requirement and submitted during approval time .

5

-

-

... More
Supply, Installation, Testing and installation of Cat - 6, Min 8 port 10/100/1000 Mbps layer 2 POE switch with rack mounting brackets with minimum 2 numbers of SFP slots ,with all accessories required for complete installation as required as directed by the engineer in charge. The switch should be capable to provide sufficient power budget to 8 IP cameras as per the requirement. Backplane capacity & PoE consumption details should be calculated and submitted along the material approval request it should have a minimum backplane of 20 GBPS and 80W PoE.

1

-

-

... More
Supply, Installation, Testing and installation of Cat - 6, 24 port 10/100/1000 Mbps, layer 2, POE, switch with rack mounting brackets, minimum 4 numbers of SFP slots ,with all accessories for complete installation as required as directed by the engineer in charge. The switch should be capable to provide sufficient power budget to IP cameras as per the requirement. Backplane capacity & PoE consumption details should be calculated and submitted along the material approval request and should have a minimum backplane of 96 GBPS.

11

-

-

... More
24 Port fully manageable Core Switch (Layer 3) with following components with minimum 300 Gbps Back Plane , Throughput Aggregate Min. - 200 Mbps, should support at least Total of 20 ports (10G/1000 Base-SFP+ and 4 Ports of SFP+/10 Gigabit copper ports or combination of both) , other required accessories,as required for complete installation and as instructed by engineer in charge/consultant with minimum 3 years technical support from the date of handover.

2

-

-

... More
10G-MMF -Transceiver fully compatible with proposed Core Switch and Layer 2 Switch with all accessories required for the configuration and completion as per confirmation with the Engineer.

6

-

-

... More
1G-MMF -Transceiver fully compatible with proposed Core Switch and Layer 2 Switch with all accessories required for the configuration and completion as per confirmation with the Engineer

28

-

-

... More
Wireless access points with dual radio, 5GHz 802.11ac 4x4 MIMO and 2.4GHz 802.11ac 2x2 MIMO (IEEE 802.11ac) with a coverage radius of Min. 25 Mtrs.standalone Manageable by controller

4

-

-

... More
RACKS

-

-

-

... More
42U Server Rack Frame/800X1000/Steel/NRS/Casters Type 3, Levellers, 19 Adopter kit / Loops, Front Back Perforated Door/800/42U/Dual/NRS, Side Panels/ 1000 / 42U/Vented/NRS, Swing Handle /Mechanical Lock / Three Point / Common Key/Die Cast Metal, ITE / Server Rack Air Circulation module/Tower Mount/360CFM, 2*Vertical Cable Manager,1Ph, 230V, 32A, Zero U standard Vertical rack mount power distribution unit with 12 X Indian Round Pin 5/15A, 2 Nos. (Inlet Plug Not Instilled, 16A MCB X 2 Circuits- PDU Rating 7.3KVA, Horizontal Cable Manager- 7 Nos

1

-

-

... More
15U Wall mounted Rack with Front glass door, Rear Perforated door with handle Lock key. Front/Rear 15U mounting angles, top, bottom open, including necessary exhaust / circulation fan, PDU with all other accessories required for complete installation as directed by the engineer in charge.

5

-

-

... More
Supply, installation, testing and commissioing of 24U Rack with Front glass door, Rear Perforated door with handle Lock key. Front/Rear 24U mounting angles, top, bottom open, RAL 9005, including necessary exhaust / circulation fan and PDU with all other accessories required for complete installation as directed by the engineer in charge.

1

-

-

... More
36U Network Rack (800W X 800D) mm floor mount closed rack with front glass door, vertical wire management systems, fan tray on top, perforated rear doors, side doors, casters, 2*Vertical Cable Manager, 7*Horizontal Cable Manager, openable entry at the bottom for the cable 2 no vertical power strip with 12 X Indian Round Pin 5/15A, with standard accessories, all necessary hardware to mount the Hardwares.

2

-

-

... More
CABLE TRAY

-

-

-

... More
Supply and fixing of Hot dip Galvanized Perforated Cable tray with Cover ,horizontal vertical bends, reducers, Tees, cross over, suitable supports and brackets and other accessories . The Tray shall be galvanized for corrosion protection .1.6 mm thickness with cover in ceiling and shafts, floor etc with complete MS supports fabricated per site requirements. It should also include the cost of bends, tees etc as required.300 x 60 x 1.6 mm thick.

50

-

-

... More
Supply and fixing of Galvanized Perforated Cable tray with Cover horizontal vertical bends, reducers, Tee cross over, suitable supports and brackets and other accessories . The Tray shall be galvanized for corrosion protection ,1.6 mm thickness with cover in ceiling and shafts, floor etc. with complete MS supports fabricated per site requirements. It should also include the cost of bends, tees etc. as required. 150 x 60 x 1.6 mm thick

370

-

-

... More
Lubricated HDPE Pipe(Outdoor) for OF Cable (100mm ID) Flexible as per TECHspecification

75

-

-

... More
ACCESS CONTROL SYSTEM

-

-

-

... More
Biometric / Card Reader with on board TCP/IP facility with display. The reader shall have the capacity to store minimum of 5000 cards, 1000 fingerprints 40000 events as minimum. (For attendance / Payroll function), Should be able to connect USB/LAN/Serial to take user information(logs). Including software to take basic attendance. with all accessories required for complete installation as directed by the Engineer in charge.(Vendor can Quote with display Card reader with seperate controller also)

2

-

-

... More
Supply, Installation, Testing Commissioning of IP Based 2 Door Controller supports minimum 6 inputs, and 4 Relay outputs with enclosure,4 Reader support, power supply and all the necessary accessories including integration with Fire alarm system.

5

-

-

... More
Supply, Installation, Testing commissioning of proximity card readers to support with the proposed controller/reader.

6

-

-

... More
Supply of Printable Proxy Cards which can read/ write CSN No and Sectors

300

-

-

... More
Supply, fixing, testing and commissioning of exit switch with Faceplate, suitable PVC / GI Modular Back Box etc. in recess / surface mounted including necessary connections with all accessories required for complete installation as directed by the Engineer in charge.

6

-

-

... More
Single leaf door Electro Magnetic lock having Min holding force of 600LBS. with required mounting accessories, ZL brackets (wherever required) glues,and all accessories for all type of doors and with external (surface / recess mountable) door contacts. The lock should have dual colour LED.

2

-

-

... More
Double leaf door Electro Magnetic lock having Min holding force of 600LBS. with required mounting accessories, ZL brackets (wherever required) for all type of doors and with external (surface / recess mountable) door contacts. The locks should have dual colour LED .

4

-

-

... More
Resettable Press to open type Emergency door release box (Green) with a relay contact to indicate to the access controller when it is operated, the EDR should be monitored in by the ACS controller.

6

-

-

... More
Supply, Installation, Testing Commissioning of Access control system Software for managing access control system including user enrolling and card registration, including Time attendance for the feature for the access control as instructed by the should give proper training for the operators for proper usage.It should be capable to connect with 3rd party ERP or any HMS software. Vendors can quote single or seperate software for access control and time attendence purpose.

1

-

-

... More
Supply, laying, testing and commissioning of 4C x1 Sqmm armored FRLS copper cable between controller and magnetic lock including termination with all necessary accessories

110

-

-

... More
Supply, laying, testing and commissioning of 8C x 1 Sqmm armoured FRLS copper cable between controller and reader including termination with necessary connectors and accessories.

110

-

-

... More
Supply, laying, testing and commissioning of 2C x 1 Sqmm armoured FRLScopper cable between controller and reader including termination with necessary accessories

220

-

-

... More
Supply of Monitoring PC Work Station Intel Min i7 processor with min 8 GB RAM, 2 GB Graphics card, 256GB SSD, 1TB HDD, Network Interface 10/100 MBNIC, Wireless Mouse ,Original Windows Software, Anti virus software ( vendor to indicate the list of other additional software considered in their offer) software (VMS/CMS) for CCTV integration WITH 19/21 monitor.

1

-

-

... More
PA SYSTEM

-

-

-

... More
Wall Mounted Speaker - Supply, fixing, testing and commissioning of Indoor Cabinet/Wall type Speakers with inbuilt line matching transformer with power 12W/15W -MDF built-Color should be selected as per the incharge/consultant as per the site situation.

25

-

-

... More
Ceiling Mounted Speaker - Supply, fixing, testing and commissioning of Metal body ceiling mount speaker with Metal Grille with inbuilt line matching transformer with power 6W with required accessories for installation as required.

93

-

-

... More
Power Amplifier - Supply, fixing, testing and commissioning of Power Amplifier of 480 Watts with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.

1

-

-

... More
Supply and Installation of Power Amplifier - Supply, fixing, testing and commissioning of Power Amplifier of 240 Watts with necessary jacks and cable for connections and interconnection with all accessories required for installation as required.

4

-

-

... More
Call Stations - Supply, fixing, testing and commissioning of 6 Zone Calling Station with mic, which can be expandable minimum up to 12 Zones(optional) including as per the drawing as required for complete installation.

1

-

-

... More
Controller - Supply, fixing, testing and commissioning of Master zone controller with routing zone capacity of minimum 6 zones with all accessories expand up to minimum 12 zones including interconnection cables, devices and jacks as required for complete installation.with PTT Microphone. The work also include integration with Fire Alarm System (FAS) including to play the prerecorded message in case of fire and evacuation. Built in / Added 240 Watts amplifier.

1

-

-

... More
Audio / Video player - Supply, installation, testing commissioning of Audio/Video player with USB option with all accessories like jacks and codes for complete installation as required as directed by the Engineer in charge.

1

-

-

... More
Speaker Cable - Supply and laying of 2 Core, 16 AWG (stranded copper conductors cable through 20/25mm PVC conduit along cable tray /wall and as instructed by engineer in charge/consultant and making good all damages made for installation.

1580

-

-

... More
SUBHEAD 8 - MEDICAL GAS PIPELINE SYSTEM

-

-

-

... More
SITC of Oxygen Manifold - 2 banks x 10 cylinders

1

-

-

... More
SITC of Fully Automatic Oxygen Control Panel with minimum flow rate of 1000 LPM

1

-

-

... More
SITC of Emergency Oxygen Manifold - 2 banks x 5cylinders

1

-

-

... More
SITC of Oxygen Flowmeters with humidifier bottle

60

-

-

... More
SITC of Nitrous Oxide Manifold - 2 banks x 1 cylinders

1

-

-

... More
SITC of Fully automatic Gas Control Panel for Nitrous Oxide with a minimum flow rate of 300 LPM

1

-

-

... More
SITC of Emergency Nitrous Oxide Manifold - 1 bank x 1 cylinders

1

-

-

... More
SITC of Carbon Dioxide Manifold - 2 banks x 1 cylinders

1

-

-

... More
SITC of Fully automatic Gas Control Panel for Carbon Di Oxide with minimum flow rate of 300 LPM

1

-

-

... More
SITC of Emergency Carbon Dioxide Manifold - 1 bank x 1cylinders

1

-

-

... More
SITC of Compressed air plant system having minimum free air delivery of 1500 LPM with complete accessories as mentioned in technical specifications.

1

-

-

... More
SITC of vacuum plant system having minimum free air aspirated of 1500 LPM at 450 mmHg with complete accessories as mentioned in technical specifications.

1

-

-

... More
Ward Vacuum Units

60

-

-

... More
Theatre Vacuum Units

7

-

-

... More
SITC of ICU Terminal Units - Imported - O2

82

-

-

... More
SITC of ICU Terminal Units - Imported - Air

41

-

-

... More
SITC of ICU Terminal Units - Imported - VAC

82

-

-

... More
SITC of Ward Terminal Units - Indigenous - O2

63

-

-

... More
SITC of Ward Terminal Units - Indigenous - N2O

1

-

-

... More
SITC of Ward Terminal Units - Indigenous - Air

1

-

-

... More
SITC of Ward Terminal Units - Indigenous - Air 7 bar

2

-

-

... More
SITC of Ward Terminal Units - Indigenous - Vac

63

-

-

... More
SITC of Matching Probe - O2

145

-

-

... More
SITC of Matching Probe - N2O

1

-

-

... More
SITC of Matching Probe - Air

42

-

-

... More
SITC of Matching Probe - Air 7 bar

2

-

-

... More
SITC of Matching Probe - VAC

145

-

-

... More
SITC of Master Plant Alarm Panel (post source), BMS compatible

1

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 6 Services

7

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 4 Services

6

-

-

... More
SITC of Area Valve Service Units with Alarm Systems - 2 Services

7

-

-

... More
SITC of Copper pipe - per mtr. - 12mm

1637

-

-

... More
SITC of Copper pipe - per mtr. - 15mm

1342

-

-

... More
SITC of Copper pipe - per mtr. - 22mm

1480

-

-

... More
SITC of Copper pipe - per mtr. - 28mm

362

-

-

... More
SITC of Copper pipe - per mtr. - 35mm

18

-

-

... More
SITC of Copper pipe - per mtr. - 42mm

177

-

-

... More
SITC of Copper pipe - per mtr. - 54mm

88

-

-

... More
SITC of Copper pipe - per mtr. - 76mm

1

-

-

... More
SITC of Ball Valves - 15mm

8

-

-

... More
SITC of Ball Valves - 22mm

6

-

-

... More
SITC of Ball Valves - 28mm

8

-

-

... More
SITC of Ball Valves - 35mm

2

-

-

... More
SITC of Ball Valves - 42mm

4

-

-

... More
SITC of Ball Valves - 54mm

1

-

-

... More
SITC of Bed Head Units - 1000 mm for Wards

75

-

-

... More
SITC of Bed Head Units - 1500 mm for ICU Category.

41

-

-

... More
SITC of Bed Head Panel - Running Meter

30

-

-

... More
SUBHEAD 9 - LANDSCAPING

-

-

-

... More
30.2.4.1 : Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 20 mm

49.18

-

-

... More
30.2.2 : Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

49.18

-

-

... More
30.2.3 : Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment).

49.18

-

-

... More
30.2.8 : Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

245.89

-

-

... More
30.2.9 : Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

245.89

-

-

... More
Supply and planting pearl grass with preparing the ground surface including ramming, rolling etc. complete as per the instruction of Engineer in charge.

491.78

-

-

... More
30.2.57.1 : Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unsaverieable material?s as per direction of officer in charge (excluding cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100)

60

-

-

... More
Providing and stacking of Nerium oleander (kaner) of height 45-60 cm. with 3-4 branches in poly bags of size 20 cm as per direction of the officer-in-charge.

15

-

-

... More
Supply and stacking of plant Mussaenda erythrophylla (Rosea) of height 60-75 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge..

15

-

-

... More
Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 75-90 cm. with 5-6 branches in bag of size 25 cm as per direction of the officer-in-charge.

15

-

-

... More
Supply and stacking of plant Hibiscus variegated of height 45-60 cm. with 3-4 branches and healthy variegated foliage in earthen pots of size 20 cm as per direction of the officer-incharge

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.