Infopark Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Infopark Tender

Works
Eprocure
Opening Date8 Jun 2021
Closing Date26 Jun 2021
Tender Amount₹ 17,17,321 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

500kva Uss Shifting And Allied Electrical And Civil Works At Infopark Phase2 Sez, Kochi

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and laying of HT cable - 11KV 3C X300/240 Sqmm XLPE cable through the existing constructed cable trench -- Laying of new HT incomer cable to the USS- new location and related works. Scope includes supply of cables, laying of cables with necessary clamping at equal interval as per the statutory rules, making of holes in the cable trench walls (if required) to draw out the cable/road crossing, removal and re laying of slabs covers etc and all connected works.

50

-

-

... More
Laying of 11KV HT Cable - Laying of 11KV, 3C X 300/240 sqmm HT cable through the existing constrcuted cable trench with necessary clamps at equal interval as per statutory rules, making holes in the cable trench walls (If required), removal and re laying of slabs covers and all connected works. Note: Scope include HT cable Laying only

325

-

-

... More
Shifing of 11KV 3CX300Sqmm HT XLPE Cable and 3.5CX150 sqmm LT AYFY cable from 220KV G.I.S substation yard to the proposed work site inside the campus. Scope include shifting 11KV 3CX300Sqmm HT XLPE cable of around 275 Mtr length and 3.5CX150Sqmm LT cable of around 260Mtr length in safe manner with out any damge to the cable using machineries /manual to the propsed site using vehicles. Scope include all expenes.

1

-

-

... More
Supply and making outdoor heat shrinkable type stright through Joint kit suitable for 3CX240/300 Sqmm 11KV HT XLPE cable with all acessories. Note : Outgoing cable termination to USS at RMU and Incomer cable termination at USS

2

-

-

... More
Supply and making outdoor type heat shrinkable end termination kit suitable for 3CX240 / 3CX300 Sqmm 11KV HT XLPE cable with all acessories. Note : Outgoing cable termination to USS at RMU and Incomer cable termination at USS

2

-

-

... More
Supply and laying of 3.5CX150 Sqmm LT cables through the existing constructed cable trench. Scope includes supply of cables, laying of cables with necessary clamping at equal interval as per the rules with M S supports, making of holes in the cable trench walls (if required) to draw out the cable/road crossing, removal and re laying of slabs covers etc and all connected works.

300

-

-

... More
Laying of LT Cable - Laying of 3.5CX150 Sqmm AYFY LT cable through the existing constrcuted cable trench with necessary clamps at equal interval as per statutory rules, making holes in the cable trench walls (If required), removal and re laying of slabs covers and ll connected works. Note: Scope include LT cable Laying only

300

-

-

... More
Supply and laying of 3.5CX95 Sqmm LT cables through the existing constructed cable trench. Scope includes supply of cables, laying of cables with necessary clamping at equal interval as per the rules with M S supports, making of holes in the cable trench walls (if required) to draw out the cable/road crossing, removal and re laying of slabs covers etc and all connected works.

300

-

-

... More
Supply and laying of 4CX25 Sqmm LT cables through the existing constructed cable trench. Scope includes supply of cables, laying of cables with necessary clamping at equal interval as per the rules with M S supports, making of holes in the cable trench walls (if required) to draw out the cable/road crossing, removal and re laying of slabs covers etc and all connected works

50

-

-

... More
Supply and laying of 4CX16 Sqmm LT cables through the existing constructed cable trench. Scope includes supply of cables, laying of cables with necessary clamping at equal interval as per the rules with M S supports, making of holes in the cable trench walls (if required) to draw out the cable/road crossing, removal and re laying of slabs covers etc and all connected works

900

-

-

... More
Removing and re-laying of exisitng LT cables available in the constructed trench -- Scope of work include removing and re- routing/laying of the LT cables (Size from 4CX16 Sqmm to 3.5C X95 Sqmm) laid in the existing constructed cable trenches inclduing removal and re laying of trench slabs, identificiation of cables, making holes in the trench walls and all connected works.

400

-

-

... More
Supply and making outdoor staright joint with heat shrinkable kit suitable for 3.5C X150 Sqmm XPLE LT cable

4

-

-

... More
Supply and making outdoor staright joint with heat shrinkable kit suitable for 3.5C X95 Sqmm XPLE LT cable

2

-

-

... More
Supply and making outdoorstaright joint with heat shrinkable kit suitable for 4C X25 Sqmm XPLE LT cable

1

-

-

... More
Supply and making outdoor staright joint with heat shrinkable kit suitable for 4C X16 Sqmm XPLE LT cable

4

-

-

... More
Supply and cable end Termination of PVC insulated armoured / unarmoured cables up to 1100V grade and connection of leads including the supply of Aluminum/COPPER cable lugs but including cutting stripping of cable insulation, providing double compression type glands, terminals, and armour earthing ,crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number ferrules, etc.with Gland hood to be provided at the cable end entering to the Main panel and including all labour and materials complete and as per specifications of this tender and directions of Engineer-in-charge -- 3.5CX150 Sqmm Cable

2

-

-

... More
Supply erection, Termination of PVC insulated armoured / unarmoured cables up to 1100V grade and connection of leads including the supply of Aluminum/COPPER cable lugs but including cutting stripping of cable insulation, providing double compression type glands, terminals, and armour earthing ,crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number ferrules, gland earthing etc.with Gland hood to be provided at the cable end entering to the Main panel and including all labour and materials complete and as per specifications of this tender and directions of Engineer-in-charge -- 3.5CX95 Sqmm Cable

3

-

-

... More
Supply erection, Termination of PVC insulated armoured / unarmoured cables up to 1100V grade and connection of leads including the supply of Aluminum/COPPER cable lugs but including cutting stripping of cable insulation, providing double compression type glands, terminals, and armour earthing ,crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number ferrules, gland earthing etc.with Gland hood to be provided at the cable end entering to the Main panel and including all labour and materials complete and as per specifications of this tender and directions of Engineer-in-charge -- 4CX25 Sqmm Cable

2

-

-

... More
Supply erection, Termination of PVC insulated armoured / unarmoured cables up to 1100V grade and connection of leads including the supply of Aluminum/COPPER cable lugs but including cutting stripping of cable insulation, providing double compression type glands, terminals, and armour earthing ,crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number ferrules, gland earthing etc.with Gland hood to be provided at the cable end entering to the Main panel and including all labour and materials complete and as per specifications of this tender and directions of Engineer-in-charge -- 4CX16 Sqmm Cable

4

-

-

... More
Re-arrangement of outgoing LT cables from USS and LT distribution panel -- Removal of existing end termination of outgoing cables from the USS, re-laying cables back to the cable trench, arrangement of excess loop in the cable trench including cable clamping and arrange the cables in a orderly manner.

1

-

-

... More
Excavation of earth at depth of 60CM and width of 45CM mtr for laying LT cables -- Scope of works include excavation of earth in manual/using machineries, laying of LT cable, use slab/brick for cable protection, re-filling of earth after cabe laying and to make in original position

50

-

-

... More
Supply, installation, testing and commissioing of outdoor double door floor mounted type feeder pillar for street light with 63A FP MCCB with in built over current protection as incomer, 6 Nos 40/32A TP MCB as outgoings, with overvoltage/under voltage relays, Ammeter and voltmeter in the incomer, RYB indication lamp,neutral link, earth bar, rain guard, double earting of feeder pillar using pipes, civil foundation all other related works. Note : Prior approval shall taken for panel GA drawing and foundation drawing

1

-

-

... More
Supply and providing Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure of minimum 450x450mm with heavy duty cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.

3

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 meterbelow ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) .

35

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) .

15

-

-

... More
Preparation of scheme and obtain scheme approval, arrange inspection and obtain final snaction order from Electrical Inspectorate and preparation of As fitted drawing including all expenes. Note: We will reimburse the statutory fees remitted to the electrical inspectorate on submission of receipt

1

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil at the places pointed out within Infopark Ph II.All kinds of soil

30

-

-

... More
Demolishing RCC work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer -in -charge.

1

-

-

... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking the same at the places pointed out within Infopark Ph II.

1000

-

-

... More
Dismantling roofing including ridges, hips, valleys and gutters etc., andstacking the material within 50 metres lead of:G.S. Sheet

50

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)

3

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

1

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, for base slab & all type of foundations excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size.

3

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

5

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

2

-

-

... More
Providing, hoisting and fixing up to floor level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but excluding cost of reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone - III) : 3 graded stone aggregate 20 mm nominal size)

1

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete

15

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights Walls (any thickness) including attached pilasters, butteresses, plinth and stringcourses etc.

50

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heightsSuspended floors, roofs, landings, balconies and access platform

15

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars

1100

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 (1 cement : 6 coarse sand) etc complete

3

-

-

... More
12 mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement: 4 fine sand)

20

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape,colour and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

50

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses andframed work, including cutting, hoisting, fixing in positionand applying a priming coat of approved steel primer all complete.

100

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

1600

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

150

-

-

... More
Supply and filling of 12mm stone aggregate for filling inside the fencing

3

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer

50

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

50

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.