Infopark Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_INFOP_691803_1Bid Award Id
ViewTender No
Infopark/e-Tender/027/2024-25Tender Authority
Infopark ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling tile work in floor and wall laid in cement mortar/adhesive including disposal of unserviceable material in dumping yard outside the campus as per directions of Engineer-in-charge
45
-
-
Dismantling water closet carefully, clearing away and stacking the material in the stockyard within infopark campus as per directions of Engineer-in-charge.
3
-
-
Dismantling wash basin, sink including Fittings (cp cock & angle cock) etc. carefully, clearing away and stacking the material in the stockyard within infopark campus as per directions of Engineer-in-charge.
1
-
-
Dismantling urinal carefully, clearing away and stacking the material in the stockyard within infopark campus as per directions of Engineer-in-charge.
2
-
-
Dismantling Pillar cock , angle cock, health fucet, sink tap etc. carefully, clearing away and stacking the material in the stockyard within infopark campus as per directions of Engineer-in-charge.
12
-
-
Dismantling Consealed pipe line carefully, clearing away and stacking the material in the stockyard within infopark campus as per directions of Engineer-in-charge.
20
-
-
Dismantling mirror carefully, clearing away and stacking the material in the stockyard within infopark campus as per directions of Engineer-in-charge.
1
-
-
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
420
-
-
Solid block masonry using precast solid blocks factory made of size 40x20x10 cm or nearest available size confirming to IS 2185 part 1 of 1979 for superstructure of thickness 10 cm and above in CM 1:6 etc complete as per directions of Engineer-in-charge.
5
-
-
Providing and laying vitrified floor tiles of size 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades in skirting riser of steps over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with matching colour epoxy filling width upto 5mm., complete as per directions of Engineer-in-charge.
30
-
-
Providing and laying vitrified wall tiles of size 600x600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades in skirting riser of steps over suitable adhesive of manufacturer's specification , including grouting the joints with matching colour epoxy filling width upto 5mm. and pvc corner profiles, complete as per directions of Engineer-in-charge.
70
-
-
Making chases by cutting floor or wall up to 25 cm in width and 12.5 cm in depth including making good and finishing with matching surface of floor(tile) and wall for race way or conduits installation.
5
-
-
Rough plastering for dadoing - Providing 6 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished rough to receive dadoing etc. complete as per directions of Engineer-in-charge.
70
-
-
Smooth plastering of surface for painting - providing 12 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) finished with a floating coat of neat cement etc complete as per directions of Engineer-in-charge
50
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface etc complete as per directions of Engineer - in - charge.
500
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per directions of Engineer - in - charge.
60
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade two or more coats including application of suitable primer as per directions of Engineer-in-charge.
30
-
-
Painting two or more coats with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour as per directions of Engineer-in-charge.
500
-
-
Providing & applying of Melamine polyshing works for existing wood works with one or more coats of puty for puchering, sandering for smooth and two coats of suitable primer and one or more coats of polyshing adhesive as per the manufacturer instruction given for smooth finishing including hire charges of spraying machine, materials, labours etc. complete as per the directions of Engineer -in- Charge.
10
-
-
Providing and fixing at all height false ceiling conforming to IS:2095 (BS 1230) including providing and fixing of frame work made of special sections power pressed from GI sheet and galvanized in accordance with zinc coating of grade 350 as per IS:277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm dia x 40mm long with 6 mm dia bolts to the angle hangers of 25x 25x 0.55 mm of required length, and other end of angle hanger being fixed with nut and bolts to GI channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to GI channel with connecting clips made out of 2.64mm dia x230 mm long GI wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20 mm and 30 mm long, The perimeter of ceiling shall be fixed to wall / partition with the help of raw plugs at 450 mm centre to centre with 25 mm long drive-all screws @ 230 mm interval including jointing and fixing to a flush finish of tapered and square edges of the gypsum board with recommended filler, paper tapes, finisher and two coats acrylic emulsion paint over two coats of primer suitable for gypsum board as per manufacturers specification after application of E-Mix / Pop / Gypsum putty and all as per manufacturer’s specification etc complete and all as directed.and also including the cost of making openings for light fittings, grills, diffusers, trap doors, cutouts made with frame of perimeter channels suitably fixed all complete as per specification and direction of the Engineer-in-charge. Vertical areas in drop ceiling will be measured separately.
-
-
-
12.5 mm thick tapered edge gypsum plain board
52
-
-
Decorative ceiling using 12.5 mm thick gypsum plain board as per the design
20
-
-
Moisture resistant board
14
-
-
Providing and fixing in true horizontal level false ceiling with GI metal ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop made of GI sheet having galvanising of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyster powder coated of thickness 60 micron (minimum), including factory painted after bending and perforation, and backed with black glass fibre acoustical fleece laid in silhouette grid system with 15mm white flanges incorporating a 6mm central reveal in white/ black colour manufactured by approved supplier, using hot dipped galvanized steel section, exposed surface chemically cleaned capping pre-finished in baked polyester paint wall angle of size 3000mm x 19mm x 19mm used in periphery of the ceiling fixed to the wall partition/ RC column/ band walls with the help of screws at 600mm c/c. Main runner to be suspended from celing using GI slotted cleats of size 27x37x25x1.5 mm fixed to celing with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvasined butterfly level clips of size 85x30x0.8 mm spaced at 1200 mm c/c along main tee and 1200mm long cross tee to be interlocked between in Main runner at 600mm c/c (max) to form a grid of 1200 x 600mm long cross tee fixed in between 1200mm long cross tee for forming a grid of 600mm x 600mm. The rate shall be inclusive of making openings for light fittings, grills, diffusers, cutouts, wastage and necessary hardware etc. The grid tiles which are replaced by diffucers/ lights should be handed over to Infopark.
90
-
-
Providing and fixing 100 mm overall thickness partition with 12.5 mm thick double skin tapered edged Gypsum board conforming to IS:2095: Part 1 upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm(both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling/roof truss at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification Air gap between the plasterboards is to be lined with 50 mm thick approved fiberglass wool and the contractor must ensure that the fiberglass wool is wire-braced to prevent it from ‘lumping down’ over a period of time. The rate shall be inclusive of providing aluminium skirting 100 mm high and 1mm thick of approved make aluminium profile with natural color andoizing fixing at bottom on both side of the partition.and as per directions of Engineer in charge all complete.
10
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position
15
-
-
Straight Glazed Partition-Slim line partition of approved make: Supply and installation of full height straight glass partition 12mm thick toughened glass and proprietary black powder coated aluminium sections of the SLIM LINE series of approved make 45x25mm thick. Providing widline section (105x25mm) at around the door two vertical upto false ceiling and horizontal at door top. The sections shall be matt natural anodized and shall be a combination of SAP 004 and 005 on all four sides as per the manufacturers specification and shall be inclusive of all accessories like stake1, stake3 and wedge 3G/B from FFL to the bottom of false ceiling height. The glass joints shall be filled with silicon sealant / beading on both side and the vendor has to prepare the shop drawing for client / Architects approval. Rate shall include for providing transport charges, handling, loading and unloading, Installation, protecting the module and glass till handing over, testing, commissioning all necessary hardware's, scafolding,wastage, Structural supports if any, etc. complete and all as per manufacturers specifications as directed.
15
-
-
Providing and fixing 12 mm thick frameless toughened patch fitting glass door (area not greater than 2.5sqm) of approved brand and manufacture, including providing and fixing top & bottom pivot, cornor fittings, patch fittings, floor spring with SS cover plate, lock with euro profile cylinder keys 3 nos, strike patch for lock, door stopper, pull handle SS Satin finish & for fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge. (Approximate door size : 1100 x 2100 mm or nearest)
2
-
-
Glass film : Fixing to glass panels using 3M film stickers of approved model and colour as per required pattern and shape and as directed. The vendor shall submit required warranty certificates from the manufacture.
10
-
-
Providing and fixing of window roller blinds of chain driven system of approved make as per manufacturer's specifications with all accessories as required for the work
30
-
-
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured
120
-
-
Providing and fixing white vitreous china extended wall mounting water closet of approved make and suitable size of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including P trap, soft close seat cover, and cistern fittings, nuts, bolts and gasket etc complete. Works including cutting and making good the walls /floor wherever required, including cost and conveyance of all materials to the site, all labour charges, all taxes etc., complete finished item of work and as directed by the SiteEngineer/Project In-Charge. The side gap between ewc mouth and pan connector to be filled with silicon sealant. (Basic rate of water closet not less than 12,500/- including GST)
3
-
-
Providing and fixing white vitreous urinal of suitable size of approved shape with inlet from back side and pressmatic auto closing concealed urinal flush valve with wall flange, including fixing to wall with suitable brackets all as per manufacturers specification and as per directions of Engineer-in-charge . (Basic rate of urinal plus Flush valve not less than 9,000/- including GST)
2
-
-
Providing and fixing washbasin with integrated half pedestal of approved make and colour along with CP fittings of approved make such as 15mm CP brass pillar cock, 15mm CP brass angular stop cock, 32mm dia CP brass waste coupling, 32mm dia CP brass bottle trap with extension pipe including necessary supporting brackets, connection tube etc; complete. The supporting brackets, bolt and nuts supplied by the contractor. Works including cutting and making good the walls /floor wherever required, including conveyance of all materials to the site, all labour charges, all taxes etc; complete. (Basic rate of wash basin not less than 11,300/- including GST)
3
-
-
Providing and fixing beveled edge mirror of superior glass (of approved quality) complete fixed with stainless steel flat headed mirror screw and washers complete etc. as per directions of Engineer-in-charge. (approx. size of mirror - 550mm x 750mm)
3
-
-
Supply and installating of Kitchen sink with single bowl with tray and Sink cock. The rate includes transportation and material cost, labour charge for fixing, etc. as per the directed by Engineer-in-charge. (Kitchen Sink - Nirali & Sink cock - Jaquar)
1
-
-
Supplying and fixing CP Health Faucet of superior quality including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. (Basic rate of health faucet not less than 1,600/- including GST)
3
-
-
Supplying and fixing CP Angle cock of superior quality including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. (Basic rate of angle cock not less than 1,200/- including GST)
6
-
-
Supplying and fixing of CP Anti cockroach floor trap gratings which consisting floor drain grating, inner filter and out filter and rim, fixed over the floor trap. Works including cleaning of floor traps before fixing the gratings. While fixing the gratings, flooring should be cut to required size of grating, (not more than 2mm of the grating sizes) using tile cutter etc; complete. The gap should be filled silicon sealant to match the flooring color. The color and shape of the gratings shall be got the approval from Infopark. To avoid damage of the cp gratings, acid cleaning of flooring shall be done before fixing of gratings.
6
-
-
Supplying, fixing and testing of 110 or 75 mm dia SS Floor clean out used in sunken floors, 75 or 110 mm dia extension boss tee arrangements.
3
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. After laying the pipes, before closing the pipes, Pressure test to be conducted and get the approval from the Engineer-in-charge. Internal work- Concealed work, including cutting chases and making good the walls etc.
-
-
-
20 mm nominal outer dia pipes
10
-
-
25 mm nominal outer dia pipes
12
-
-
32 mm nominal outer dia pipes
10
-
-
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. The frames shall be fixed in existing opening including with dash fasteners/ chemical fasteners of appropriate size ( 3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including cost of dash fasteners/ chemical fastener etc. complete as per directions of Engineer-in-charge.
30
-
-
Providing and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames, Handles latch with/without lock (as per site condition) with 2 keys, door closer, tower bolt etc. complete as per directions of Engineer-in-charge.
10
-
-
Fabrication, supply and installation at site open office type modular workstations Linear Double sided of size 1100x600mm; Leg and beam desk system of following specification and size. Table top: 25 mm thick prelaminated particle board with 2mm thick PVC edge band lipping, access flap wire manager: Understructure: Made of ERW tubular structure of size 50x50mm 1.6 mm thick powder coated with suitable levelers; power beam for integrated wire management, raceways, Privacy screens :Sandwitch glass screens with 8 mm thick laminated glass of approved colour supported on brackets duly powder coated; Raceway: Two numbers vertical and horizontal for data and power with provision for sockets/data below table top.
16
-
-
Fabrication, supply and installation at site open office type modular workstations Linear single sided of size 1000mmx600mm; Leg and beam desk system of following specification and size. Table top: 25 mm thick prelaminated particle board with 2mm thick PVC edge band lipping, access flap wire manager: Understructure: Made of ERW tubular structure of size 50x50mm 1.6 mm thick powder coated with suitable levelers; power beam for integrated wire management, raceways, Privacy screens :Sandwitch glass screens with 8 mm thick laminated glass of approved colour supported on brackets duly powder coated; Raceway: Two numbers vertical and horizontal for data and power with provision for sockets/data below table top.
6
-
-
Supplying and placing in position High back mesh chairs with ergonomic design, good lumbar support, seating comfort, Seat with high density PU foam upholstered with approved quality fire retardant fabric, mesh back, Hydrualic gas lifting mechanism, Tilt locking mechanism, fixed armrest with integral PU skin metal inserted arm rests, five pronged chrome base with nylon castors.
11
-
-
Supplying and placing in position Medium back task mesh chairs for workstations with ergonomic design, good lumbar support, seating comfort, Seat with high density PU foam upholstered with approved quality fire retardant fabric, mesh back, Hydrualic gas lifting mechanism, Tilt locking mechanism, fixed armrest with integral PU skin metal inserted arm rests, five pronged chrome base with nylon castors.
27
-
-
Supply and installation of Pantry Chairs stackable type with Polypropylene seat and back and stainless steel legs, of colour and shade as approved by Engineer-in-charge.
12
-
-
Supplying and installing in position Pantry table of size 1200 x 750 x 750 mm having 25 mm thick prelaminated particle board, edge banded and stainless steel understructure, of colour and shade as approved by Engineer-in-charge.
3
-
-
Supplying and placing in position Conferance table of size 2800mmx1000mm of approved make and following specification: table top made of 25 mm thick prelaminated particle board edges postformed/ 2mm PVC edge banding; table supported on 50x50 mm square pipe made of 1.6mm thick CRCA powder coated legs and beams 100 mm x 190 mm made of 1.2mm CRCA powder coated, tie member 80x40mm pipe made of 1.6 mm powder coated CRCA, levellers made of 100% recyclable nylon 6M8 bolt insert, switches to be mounted on beam or fliptop
1
-
-
Fabrication, supply and installation at site office Reception table 1500x600mm and height 1050/765 mm size using 24 mm thick BWR plywood for Table top and 19 mm ply for undersupport covered with laminate and table top edges finished with edge band lipping; table top finished with 4mm veneer in melamine polish finish, storage pedestal with three drawers including all necessary hardwares, etc complete as per directions of Engineer-in-charge.
1
-
-
Supplying and placing in position single seater Sofa of approved make made from wooden frame with steel for arm and back, fully upholstered arm panels, seat and back, sofa finished with leatherite material of approved colour as per directions of Engineer-in-charge. (Product should be BIFMA certified)
3
-
-
Supplying and placing in position executive table for cabins of sizes: Main table of size 1500x600mm and return table of size 1000x400mm of approved make and following specification: table top made of 25 mm thick prelaminated particle board edges postformed/ 2mm PVC edge banding; table supported on 50x50 mm square pipe made of 1.6mm thick CRCA powder coated legs and beams 100 mm x 190 mm made of 1.2mm CRCA powder coated, tie member 80x40mm pipe made of 1.6 mm powder coated CRCA, levellers made of 100% recyclable nylon 6M8 bolt insert, switches to be mounted on beam or fliptop, storages three door pedestal 400x435x543mm size.
1
-
-
Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
1
-
-
Supplying and fixing 12 way,double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2
-
-
Supply and installation 40A, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supply and installation 25A, DP MCB in the existing VTPN DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supply and installation 32A, TP MCB in the existing VTPN DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supplying and fixing 25A, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supply and installation 40A double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
2
-
-
Supply and installation Single pole, 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
10
-
-
Supply and installation single pole blanking plate in the existing MCB DB complete etc. as required.
4
-
-
Supply and installation of 20 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
340
-
-
Supply and installation of 25 mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
770
-
-
Supply and installation of 20 mm medium class PVC flexible conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
40
-
-
Supply and installation of 25 mm medium class PVC flexible conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
60
-
-
Supply and drawing 3 X 1.5 sq.mm ISI marked FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
500
-
-
Supply and drawing 3 X 2.5 sq.mm ISI marked FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
500
-
-
Supply and drawing 2 X 4 sq.mm and 1 x 2.5 sq mm ISI marked FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
136
-
-
Supply and drawing 2 X 6 sq. mm and 1 X 2.5 sq mm ISI marked FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
50
-
-
Supplying and fixing 6A Switches (4 nos) for 4 module, GI box alongwith modular base & cover plate for modular switches in recess etc.
4
-
-
Supplying and fixing 6A Switches (3 nos) for 3 module, GI box alongwith modular base & cover plate for modular switches in recess etc.
6
-
-
Supplying and fixing 6A Switches (2 nos) for 2 module, GI box alongwith modular base & cover plate for modular switches in recess etc.
2
-
-
Supply and installation with modular plate and cover in front on surface or in recess, including providing and installation 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required in the work stations for raw power .
38
-
-
Supply, installation, testing and commissioning of 1 No. of 15/16A Universal (Flat type/Round type ) 6 Pin Raw Power Socket and 16A switch 1No. with GI modular box and face plate and all other acessories.
7
-
-
Supply and installation with modular plate and cover in front on surface or in recess, including providing and installation 1set 6/16 A modular universal socket outlet with 16A modular switch and 1set 6 A modular universal socket outlet with 6A modular switch , connections etc. as required in a single modular plate for UPS power
64
-
-
Providing and installation 4.00 (8 SWG) mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
20
-
-
Supply & installation of 36W LED (Recessed mount type suitable for 2X2 grid ceiling) light fixtures using efficient optics system lumen, fully acrylic LED luminaire, CRCA housing with high efficiency opal diffuser, zero maintenance, zero mercury System Wattage: 36Watts Efficiency 100 lumen/Watt CRI 75%.
20
-
-
Supply & installation of 15W LED round light fixture(Recessed mount type)with cool day light (Model: Havells ENDURA NEO DLR 15W LED 840 MOD or Equivalent)
20
-
-
Supply and drawing 1 run of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1600
-
-
Supply, Installation ,testing & commissioning of category 6U /UTP outlet for voice and data
30
-
-
Supply and installation of 2-Port Faceplate Shuttered Square type White colour cost include blank insert required for all
30
-
-
Supply and installation Cat 6 1m Patch Cords of required length
60
-
-
Supply and installation Cat 6 24 Port Jack panel - preloaded Source Panel with all connected accessories
2
-
-
Supply and installation Cat 6 24 port unloaded patch panel with all connected accessories
2
-
-
Supply and installation 15U closed Rack with Mounting Accessories with all connected accessories + Supply and installation Power distribution unit for rack - 6 sockets per board
1
-
-
Supply, Installation ,testing & commissioning of 2.44m floor race way of size 100x38 mm with cover
8
-
-
Supply, Installation ,testing & commissioning of 2.44m floor race way of size 50x38 mm with cover
8
-
-
Supply and installation of 38 mm PVC Channel (Casing cap)
50
-
-
Supply and installation of PVC Channel 50x50 (Trunking)
50
-
-
Supply,Installation, testing and commissioning of 6kg capacity ABC type fire extinguishers with wall mounting brackets or stand for floor mounting as per latest I.S.
3
-
-
Supply, installation, testing and commissioning of 3star 1.5TR copper INVERTER TYPE split AC indoor and outdoor units with copper pipe kit including all materials and labours. Approved Make: Bluestar/ Carrier /Mitsubishi/ Hitachi.
8
-
-
Supply and laying of suitable size suction and delivery copper pipes between indoor and outdoor units with nitrile rubber insulation of minimum thickness 19mm of the copper pipe lines, wrapping with white colour tapes and clamping at equal interval.
Note: This item applicable for additional pipe length between indoor and outdoor units, in addition to the available Copper pipe kit with new AC units.
130
-
-
Supply and laying of 3core X 2.5 Sqmm flexible cables between indoor and outdoor units.
130
-
-
Supply and laying of 25mm/32mm drain pipe with insulation
130
-
-
Supply and installation of wall mountable type outdoor unit mounting stand.
8
-
-
Dismantling of existing split AC units- indoor and outdoor units, copper pipes,cables and drain line. Shifting of these materials in the store room and disposal of unusable materials in dumping yard outside the campus as directed by Engineer-in-charge.
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements