Indian Institute Of Information Technology And Management Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Indian Institute Of Information Technology And Management - IIITM Tender
Software and IT Solutions
Eprocure
Opening Date21 Jan 2019
Closing Date25 Feb 2019
Tender Amount₹ 5,96,00,000 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 11,94,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_IIITM_262992_1Bid Award Id
ViewTender No
IIITMK/0659/19Tender Authority
Indian Institute Of Information Technology And Management ViewPurchaser Address
-Website
http://https://www.iiitmk.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Wiring for power plug with 2x4 sq.mm FRLS PVC insulated stranded copper conductor single core cable in surface / recess steel conduit along with 1 no. 4 sq.mm FRLS PVC insulated stranded copper conductor single core cable for loop earthing as required.
-
-
-
... More
SUB DISTRIBUTION BOARDS (SDB)
(Refer item no. 2 of Volume III BOQ)
-
-
-
... More
a) 8 way SPN (2+8) Double Door DB, with incomer 32/40A DP MCB as Incoming & 8 nos. Slots for 6-32A SP MCB, 10 KA as outgoing. (Academic Block)
6
-
-
... More
b) 4 way SPN (2+4) Double Door DB, with incomer 32A DP MCB as Incoming & 4 nos. Slots for 6-32A SP MCB, 10 KA as outgoing. (Hostel Block & Substation)
2
-
-
... More
C) Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
LT CABLES AND CABLE TRAYS
-
-
-
... More
Supply of LT Cables Supply of following sizes 1.1 KV XLPE insulated, FRLS Al. armoured Conductor, PVC inner sheathed, overall PVC sheathed cable in conformity to the technical specification and as per latest IS - codes. a) 4C x 10 sq. mm.
180
-
-
... More
Cable End Terminations Supply and making end termination with double brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 4C x 10 sq. mm.
18
-
-
... More
Laying of LT cables Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle)
162
-
-
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. a) Upto 35 sq. mm
18
-
-
... More
Cables Trays
(Ref. item 3.4 of Volume III BOQ) a) 600 mm width x 62.5 mm depth x 2.0 mm thickness (For ELV)
151
-
-
... More
b) 300 mm width x 50 mm depth x 1.6 mm thickness (For ELV)
50
-
-
... More
c) 150 mm width x 50 mm depth x 1.6 mm thickness (For Power)
120
-
-
... More
DISTRIBUTION BOARDS - WALL MOUNTED
-
-
-
... More
MDB-SERVER(LW) & MDB-SERVER(RW) (GROUND FLOOR - ACADEMIC BLOCK) (WALL MOUNTED)
(Refer item no.4.0 & 4.1 of Volume III BOQ )
2
-
-
... More
DISTRIBUTION BOARDS - WALL MOUNTED
-
-
-
... More
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) as required.
6
-
-
... More
Extra for using chemical for artificial treatment of soil with 20 Kgs for each earth pit as required (TERREC/TERRA GEL). The remaining space of earth pit shall be filled with agricultural soil and properly compacted.
6
-
-
... More
Providing and fixing G.I. tape 25 mm X 3 mm thick on surface of wall for complete as required.
-
-
-
... More
Supplying and laying 25 mm X 3 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
-
-
-
... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
-
-
-
... More
UPS SYSTEM
-
-
-
... More
SITC of 2KVA Double Conversion Online UPS System with Inbuilt Maintenance-free sealed Lead-Acid battery, Built-in Bypass arrangement , 230v Nominal Input Voltage and 230v Nominal Output Voltage. (Hostel)
2
-
-
... More
SITC of 1KVA Double Conversion Online UPS System with Inbuilt Maintenance-free sealed Lead-Acid battery, Built-in Bypass arrangement , 230v Nominal Input Voltage and 230v Nominal Output Voltage. (Substation)
2
-
-
... More
SWITCHES (Refer item no. 7 of Volume III BOQ)
-
-
-
... More
SITC of Core Switch As per technical specification
2
-
-
... More
SITC of 48 Port POE Switch as per technical specification
23
-
-
... More
SITC of 48 Port Non-POE Switch as per technical specification
17
-
-
... More
SITC of 24 Port POE Switch as per technical specification
11
-
-
... More
SITC of Industrial Grade access switch as per technical specification
1
-
-
... More
SITC of 8 Port POE Access Switch as per technical specification
1
-
-
... More
SITC of Server farm switch as per technical specifications
2
-
-
... More
SITC of 40G 10m DAC Cable
4
-
-
... More
SITC of SFP Modules 1G
8
-
-
... More
SITC of SFP+ Modules 10G
-
-
-
... More
SITC of 2 x 40G uplink module
-
-
-
... More
SITC of 40G to 10G Converter
-
-
-
... More
TELEPHONE
(Refer item no. 8 of Volume III BOQ)
-
-
-
... More
SITC of IPPBX as per technical specification
1
-
-
... More
SITC of IP Phones Type - 1 as per technical specification
80
-
-
... More
SITC of IP Phones Type - 2 as per technical specification
11
-
-
... More
SITC of IP Phones Type-3 as per technical specification
1
-
-
... More
SITC of Voice Gateway as per technical specification
1
-
-
... More
INFRASTRUCTURE SERVICES
(Refer item no. 9 of Volume III BOQ)
-
-
-
... More
SITC of NMS as per technical specifications
1
-
-
... More
WIRELESS
(Refer item no. 10 of Volume III BOQ)
-
-
-
... More
SITC of Wireless controller as per technical specification
2
-
-
... More
SITC of Indoor Access Point Type 1as per technical specification
112
-
-
... More
SITC of Indoor Access Point Type 2 as per technical specification
14
-
-
... More
ACCESS CONTROL SYSTEM
(Refer item no. 11 of Volume III BOQ)
-
-
-
... More
SITC of Proximity access Reader cum controller as per technical specifications
54
-
-
... More
SITC of Electro magnetic Lock - Single Leaf
16
-
-
... More
SITC of Egress Switch
16
-
-
... More
SITC of Break Glass Unit
16
-
-
... More
SITC of Access Control Software as per technical specifications
1
-
-
... More
SITC of Access Card
1500
-
-
... More
PUBLIC ADDRESS SYSTEM
(Refer item no. 12 of Volume III BOQ)
-
-
-
... More
SITC of IP Based Ceiling Speaker as per technical specification
169
-
-
... More
SITC of IP Based wall Mount speaker as per technical specification
50
-
-
... More
SITC of Call Station
1
-
-
... More
SITC of Controller
1
-
-
... More
SITC of IP Push Talk button
7
-
-
... More
PUBLIC ADDRESS SYSTEM
(Refer item no. 13 of Volume III BOQ)
-
-
-
... More
SITC of Bullet Camera as per technical specification
25
-
-
... More
SITC of Dome Camera as per technical specification
75
-
-
... More
SITC of PTZ Camera as per technical specification
6
-
-
... More
SITC of Video Management Software as per technical specification
1
-
-
... More
SITC of 55'inch Display
1
-
-
... More
NETWORK SECURITY
(Refer item no. 14 of Volume III BOQ)
-
-
-
... More
SITC of Firewall as per technical specification
2
-
-
... More
SITC of AAA with Guest Management as per technical specification
2
-
-
... More
SITC of Firewall Management
1
-
-
... More
SERVER AND STORAGE
(Refer item no. 15 of Volume III BOQ)
-
-
-
... More
SITC of Server as per technical specifications
3
-
-
... More
SITC of Storage as per technical specification
1
-
-
... More
SITC of Virtualization software as per technical specification
1
-
-
... More
SITC of IP based 8 Port KVM Switch
1
-
-
... More
PASSIVE ITEMS
(Refer item no. 16 of Volume III BOQ)
-
-
-
... More
SITC of UTP cat 6 cable as per technical specification
45213
-
-
... More
SITC of CAT6 Information Outlet & Faceplate as per technical specification
1686
-
-
... More
SITC of Copper patch Panel 48 port as per technical specification
40
-
-
... More
SITC of Copper patch Panel 24 port as per technical specification
11
-
-
... More
SITC of Cat6 patch cable 1 M as per technical specification
2184
-
-
... More
SITC of Cat6 patch cable 2 M as per technical specification
1686
-
-
... More
SITC of 24 core SM Optical fibre cable as per technical specification
794
-
-
... More
SITC of 6 core SM Optical fibre cable as per technical specification
3704
-
-
... More
SITC of 24 Port LIU Fully loaded as per the Technical specification
10
-
-
... More
SITC of 12 Port LIU Fully loaded as per the Technical specification
26
-
-
... More
SITC of Single Mode fiber Patch Cord - 3M as per technical specification
98
-
-
... More
SITC of Server Rack as per technical specification
2
-
-
... More
SITC of Network Rack as per technical specification
2
-
-
... More
SITC of Network Rack Type 1 as per technical specification
17
-
-
... More
SITC of Network Rack Type 2 as per technical specification
7
-
-
... More
SITC of Fiber distribution Rack as per technical specification
6
-
-
... More
SITC of Outdoor rack for industrial grade switch as per technical specification
2
-
-
... More
INSTALLATION
(Refer item no. 17 of Volume III BOQ)
-
-
-
... More
One time Installation, Testing, Commissioning & training of all the Active components
1
-
-
... More
Laying of CAT 6
45213
-
-
... More
Installation of IO
1686
-
-
... More
Installation of 48 port patch panel
40
-
-
... More
Installation of 24 port patch panel
11
-
-
... More
Laying of 24 core SM OFC
794
-
-
... More
Trenching of 24 core OFC
200
-
-
... More
Laying of 6 core SM OFC
3704
-
-
... More
Installation of 24 port LIU
10
-
-
... More
Installation of 12 port LIU
26
-
-
... More
Installation of ACS
1
-
-
... More
Installation of PAS
1
-
-
... More
Installation of 42 U Server rack
2
-
-
... More
Installation of 42 U Network rack
2
-
-
... More
Installation of 15 U Network rack
17
-
-
... More
Installation of 12 U Network rack
13
-
-
... More
Installation of outdoor rack
2
-
-
... More
Annual Maintenance Contract (AMC) - including Materials/Equipments and Labour (Ref. Clause 21 of SCC)
-
-
-
... More
1st Year AMC charge
1
-
-
... More
2nd Year AMC charge
1
-
-
... More
3rd Year AMC charge
1
-
-
... More
Annual Maintenance Contract (AMC) - including Labour Excluding Materials/Equipments (Ref. Clause 21 of SCC)
-
-
-
... More
1st Year AMC charge
1
-
-
... More
2nd Year AMC charge
1
-
-
... More
3rd Year AMC charge
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements