Impact Kerala Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Impact Kerala Limited Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Aug 2023
Closing Date26 Sep 2023
Tender Amount₹ 8,17,50,223 
Notes
Download

Costs

Summary

Construction Of Office Building For Pattambi Municipality

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
20.6.3.1 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Group of two or more piles upto 50 tonne capacityInitial test

1

-

-

... More
20.6.3.2 : Vertical load testing of piles in accordance with IS 2911( Part IV) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of engineer -in-Charge.Group of two or more piles upto 50 tonne capacityRoutine test

1

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

198.78

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

68.94

-

-

... More
4.1.6 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)

16.97

-

-

... More
50.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge

148.33

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

265.08

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

259.02

-

-

... More
od149716/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item shall be as per design mix.<br>All work upto plinth level

104.93

-

-

... More
50.6.1.1 : Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete

21.8

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

63.65

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

21187.42

-

-

... More
APPENDIX-B-Super Structure

-

-

-

... More
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts

719.03

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

1365.3

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

154.35

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

1965.87

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

493.16

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

207.18

-

-

... More
od149745/2023_2024 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item shall be as per design mix<br>All work above plinth level upto floor V level

555.8

-

-

... More
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

87237.73

-

-

... More
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

41.42

-

-

... More
50.6.1.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

153.84

-

-

... More
50.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

12.31

-

-

... More
od151132/2023_2024 : Solid block masonry using pre cast solid blocks ( Factory made ) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for Super structure above floor two level upto floor five level for 10cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand ) including cost of scaffolding etc complete

19.72

-

-

... More
od362253/2021_2022 : Airocon solid wall panel (Factory made) of size 3000x600x75mm or nearest available

792.13

-

-

... More
9.147A.3 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).

200.25

-

-

... More
9.147B.1 : 543 SUB HEAD : 9 - WOOD & PVC WORK 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately).br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

6.84

-

-

... More
9.117.1 : Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm

144.1

-

-

... More
9.118.1 : Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).

46.83

-

-

... More
10.5.1 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

22.68

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

3106.35

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

4294.87

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

2579.36

-

-

... More
8.31 : Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

360.31

-

-

... More
11.37 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

83.03

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

1427.1

-

-

... More
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm

34

-

-

... More
11.56.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

347.62

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

714.8

-

-

... More
10.6.1 : Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover

16.5

-

-

... More
10.7 : Providing and fixing ball bearing for rolling shutters.

2

-

-

... More
10.8.1 : Extra for providing mechanical device chain and crank operation for operating rolling shuttersExceeding 10.00 sqm and upto 16.80 sqm in the area

6.5

-

-

... More
13.26 : Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

3880.87

-

-

... More
13.40 : Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade:

6874.23

-

-

... More
13.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm

757.67

-

-

... More
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

1609.96

-

-

... More
13.48.3 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

538.49

-

-

... More
21.18 : Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

12.6

-

-

... More
25.3 : Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement

76.66

-

-

... More
25.4 : Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.

7.2

-

-

... More
9.147C.1 : Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately).br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm).

76.86

-

-

... More
21.3.3 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness

76.86

-

-

... More
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

207.09

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

329.77

-

-

... More
12.45.4 : Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:Fully Perforated Gypusm Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15% perforated area with perforation size and pattern as approved by the Engineer - in- charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60.

296.07

-

-

... More
10.16.1 : Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

4763.17

-

-

... More
12.1.2 : Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2

213.6

-

-

... More
APPENDIX C - TERRACE

-

-

-

... More
22.7.1 : Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-Charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in- Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in- Charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in Charge:With average thickness of 120 mm and minimum thickness at khurra as 65 mm

190.96

-

-

... More
50.6.1.3 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure above floor two level up to floor V level thickness 20cm and above in: CM 1:6 ( 1 cement :6 coarse sand) etc complete

31.07

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

400.19

-

-

... More
13.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

237.16

-

-

... More
25.8 : Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

383.94

-

-

... More
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

400.19

-

-

... More
APPENDIX D - OH WATER TANK

-

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

71.36

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

13.22

-

-

... More
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

1982.4

-

-

... More
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

94.3

-

-

... More
APPEDIX-E-DRIVERS ROOM

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

5.35

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

0.49

-

-

... More
7.2.1 : Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like.Cement mortar 1:6 (1 cement : 6 coarse sand)

2.22

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

14.74

-

-

... More
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

4.58

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

1.77

-

-

... More
5.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges

5.18

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

2.65

-

-

... More
5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars

265

-

-

... More
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

7.43

-

-

... More
9.147A.3 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).

4.5

-

-

... More
10.5.1 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

1.89

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

67.5

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

19.93

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

95.92

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

13.04

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

63.24

-

-

... More
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

57.6

-

-

... More
13.48.3 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

8.75

-

-

... More
10.25.2 : Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

281.43

-

-

... More
APPENDIX-F-GROUND LEVEL WATER TANK

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

285.39

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

9.04

-

-

... More
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

368.4

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

100.29

-

-

... More
5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars

16040

-

-

... More
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

450.95

-

-

... More
APPENDIX-G-SEPTIC TANK

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

57.97

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

2.31

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

113.39

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

21

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

24.2

-

-

... More
5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars

2904

-

-

... More
13.9.1 : Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster

152.82

-

-

... More
50.18.9.22.1 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow

1

-

-

... More
50.18.9.22.5 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee

1

-

-

... More
APPENDIX-H-Water supply & Sanitary Fittings

-

-

-

... More
17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

24

-

-

... More
17.7.1 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

25

-

-

... More
17.4.2 : Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern

13

-

-

... More
17.70.1 : Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms

25

-

-

... More
17.32.2 : Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm

25

-

-

... More
18.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipes

24.34

-

-

... More
17.61.1 : Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 12.5 mm nominal size) including necessary plaster and pointing in cement mortar 1:4 ( 1cement :4 coarse sand ):100 mm dia

150

-

-

... More
17.61.2 : Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 12.5 mm nominal size) including necessary plaster and pointing in cement mortar 1:4 ( 1cement :4 coarse sand ):75 mm dia

87.64

-

-

... More
18.2.3 : Providing and fixing Polyethelene - Alumininum - Polyethelene ( PE-AL- PE) Composite Pressure Pipes conforming to IS-15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80C� including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete of joints complete as per direction of the Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.2025 (25 mm OD) pipe

100

-

-

... More
18.2.4 : Providing and fixing Polyethelene - Alumininum - Polyethelene ( PE-AL- PE) Composite Pressure Pipes conforming to IS-15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80C� including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing. This includes the costs of cutting chases and including testing of joints complete of joints complete as per direction of the Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.2532 (32 mm OD) pipe

70

-

-

... More
18.3.5 : Providing and fixing Polyethelene - Aluminium - Polyethelene ( PE-AL-PE) Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80sup0/supC including all special fittings of composite material ( engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with trenching, refilling and testing of joints complete as per direction of the engineer in charges. External work3240 (40 mm OD) pipe

75

-

-

... More
18.32.1 : Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5

4

-

-

... More
18.51.1 : Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

23

-

-

... More
18.52.1 : Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore

23

-

-

... More
18.58.1.2 : Providing and fixing PTMT grating of approved quality and colour.Circular type125 mm nominal dia with 25 mm waste hole

34

-

-

... More
17.71 : Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

18

-

-

... More
17.73.2 : Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighting not less than 190 gms

18

-

-

... More
17.16A : Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge

21

-

-

... More
APPENDIX-I-UNDER GROUND DOMESTIC PUMP ROOM

-

-

-

... More
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

52.12

-

-

... More
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

2.79

-

-

... More
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

75.31

-

-

... More
5.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)

6.12

-

-

... More
5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level

13.67

-

-

... More
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

25.82

-

-

... More
5.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide

2.13

-

-

... More
5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars

1935.6

-

-

... More
5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level

2.82

-

-

... More
50.6.1.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.

5.44

-

-

... More
9.147A.3 : Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)br Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).

3

-

-

... More
10.5.1 : Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

1.89

-

-

... More
9.48.2 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc

45

-

-

... More
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)

62.07

-

-

... More
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

58.37

-

-

... More
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

54.68

-

-

... More
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

33.75

-

-

... More
13.48.1 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

53.48

-

-

... More
13.48.3 : Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

7.25

-

-

... More
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

49.9

-

-

... More
APPENDIX J (ELV WORK) SITC OF CCTV SURVEILLANCE SYSTEM:ESTIMATE - ELV WORKS

-

-

-

... More
od144994/2023_2024 : IP network indoor Dome PAL color Camera with min 1/3"<br>Progressive scan CMOS/ Progressive scan CCD / CMOS - min 2 MP<br>resolution image sensor, with min one H.264/H.265 stream for<br>recording & one MPEG 4/MJPEG stream for live viewing. It shall<br>have the capability to deliver two independenat video streams and<br>shall be possible to set independant FPS (30 fps for M-JPEG and 30<br>fps for H.264/H.265) & Compression selection (QCIF to D1 / 4 CIF)<br>for each stream with built in 3.8 mm (or) close to it, Fixed focal auto<br>DC iris lens, in indoor dome housing with built in WDR (120DB),<br>HLC& automatic back light compensation circuitry and sensitivity of<br>min 0.3 lux with IR illuminator OFF & 0 Lux with IR illuminator ON<br>(20mts IR distance), POE, also with the capability to add<br>manufacturer's power supply unit if required at site and with built in<br>WEB Browzer and required wall / ceiling mounting accessories as<br>specified in the Tender Specifications. The cameras should be UL<br>listed,ONVIF<br>

26

-

-

... More
od114752/2022_2023 : IP network Outdoor Bullet PAL color Camera (IP67, IK10) with min 1/3" Progressive scan CMOS/ Progressive scan CCD / CMOS - min 2 MP resolution image sensor, with min one H.264/H.265 stream for recording & one MPEG 4/MJPEG stream for live viewing. It shall have the capability to deliver two independenat video streams and shall be possible to set independant FPS (30 fps for M-JPEG and 30 fps for H.264/H.265) & Compression selection (QCIF to D1 / 4 CIF) for each stream with built in 3.8 mm (or) close to it, Fixed focal auto DC iris lens, in indoor dome housing with built in WDR (120DB), HLC& automatic back light compensation circuitry and sensitivity of min 0.3 lux with IR illuminator OFF & 0 Lux with IR illuminator ON (50mts IR distance), POE, also with the capability to add manufacturer's power supply unit if required at site and with built in WEB Browzer and required wall / ceiling mounting accessories as specified in the Tender Specifications. The cameras should be UL listed,ONVIF<br>

8

-

-

... More
od115875/2022_2023 : "64 Channel networked NVR System with<br>Video Input 64 channel (IPC UPnP, 16PoE ports)<br>IP Video input & output, <br>H.265/H.264/MJPEG/MPEG4 codec decoding<br>HDMI / VGA simultaneous video output. <br>RAID 5 Implimented HDD<br>Support 8 SATA Port up to 48TB, Loaded with 24TB Surveillance HDD, (HDD supplied should support 30 days recording for H.264/H.265 at 30 fps / QCF to 4CIF)<br>2 LAN Port, 2 USB Ports, HDMI Port, VGA Port, Mobile Software, CMS Software: VMS, Etc. <br>ONVIF & UL Listed"<br>

1

-

-

... More
od115884/2022_2023 : Monitoring PC Station Intel Min i5 processor or greater with min 8 GB RAM with DVD drive, V.G.A. Card, 2 GB Graphics card, dual monitor card, 1 TB HDD ,Network Interface 10/100 MBNIC, 42" LED monitor, Scroll Mouse & original Software, Sounder card, The original OS (Windows ) software, Latest MS office software, Anti virus software ( vendor to indicate the list of other additinal software considered in their offer) , min 1 HDMI Port, 2 Serial Ports, 1 Paraller port, 4 USB Ports. <br>

1

-

-

... More
od115887/2022_2023 : Cat 6A Patch cord - 2 Mtr - Gray<br>

76

-

-

... More
od115938/2022_2023 : Cat 6A Patch cord - 1 Mtr - Gray<br>

110

-

-

... More
od115939/2022_2023 : 16-port (fully loaded with 16 Nos RJ45 sockets) Modular Straight Jack Panel for Cat 6A UTP, 1U<br>

8

-

-

... More
od115940/2022_2023 : 24-port (fully loaded with 24 Nos RJ45 sockets) Modular Straight Jack Panel for Cat 6A UTP, 1U<br>

12

-

-

... More
od115941/2022_2023 : Cat6A UTP cable - through surface/ recessed medium class PVC conduit through wall/tray with all accessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. <br>

3600

-

-

... More
od115942/2022_2023 : "Cat 6A Ceiling Connector Assembly (Field Terminated <br>RJ 45 socket + jack for CCTV, WIFI Etc.)"<br>

36

-

-

... More
od115943/2022_2023 : 1-port British-style shuttered faceplate with Back Box, loaded with RJ 45 socket, WHITE Cat6A<br>

69

-

-

... More
od115944/2022_2023 : 42U Rack Frame/800X1000/Steel/NRS/Casters Type 3, Levelers, 19" Adopter kit / Loops, Front & Back Perforated Door/800/42U/Dual/NRS, Side Panels/1000/42U/Vented/NRS, Swing Handle /Mechanical Lock / Three Point / Common Key/Die Cast Metal, ITE / Server Rack Air Circulation module/Tower Mount/360CFM, Vertical Cable Manager - 1Ph, 230V, 32A, Zero U standard Vertical rack mount power distribution unit with 12 X Indian Round Pin 5/15A, (Inlet Plug Not Installed, Recommended IEC30932A 2P +E), 16A MCB X 2 Circuits- PDU Rating 7.3KVA, Horizontal Cable Manager- 7 Nos<br>

2

-

-

... More
od115945/2022_2023 : 15U (600W X 500D) mm wall mount closed rack with front glass door, vertical wire management systems, fan tray on top, 1 nos power strip with standard accessories, all necessary hardware to mount the passive & active equipment etc.<br>

3

-

-

... More
od145008/2023_2024 : 12U (600W X 500D) mm wall mount closed rack with front glass<br>door, vertical wire management systems, fan tray on top, 1 nos power<br>strip with standard accessories, all necessary hardware to mount the<br>passive & active equipment et

1

-

-

... More
od115946/2022_2023 : 9U (600W X 500D) mm wall mount closed rack with front glass door, vertical wire management systems, fan tray on top, 1 nos power strip with standard accessories, all necessary hardware to mount the passive & active equipment etc.<br>

1

-

-

... More
TELEPHONE CABLES; JUNCTION BOXES

-

-

-

... More
od115949/2022_2023 : ARMOURED PIJF TELEPHONE CABLES :- Supplying of armoured 0.51 mm ATC conductor PIJF Telephone cables of 10 pair capacity and laying the same in open trenches, Clamping on to trays etc. as required<br>

80

-

-

... More
od115950/2022_2023 : UN-ARMOURED PVC TELEPHONE CABLES :- Supplying & laying of armoured 0.51 mm ATC conductor PVC Telephone cables of 2 pair capacity and laying the same as required in surface / recessed medium class FRS PVC conduit through wall/tray with all acessories as required for complete installation and as instructed by engineer in charge/consultant and making good all damages made for installation. <br>

1625

-

-

... More
od115951/2022_2023 : SITC OF MS MDF BOXES :- Supply and Installation of following in-door type of MDF boxes with locking arrangements of 200 pair capacity including Back Frames for "KRONE" connectors (Including KRONE IDC connectors) & IPM Modules (for all incoming lines), and all necessary fixing arrangements<br>

1

-

-

... More
od115952/2022_2023 : RJ11 Wall Outlet Plain Old Telephone (POT)<br><br>

55

-

-

... More
ACTIVE SYSTEMS (SWITCHES)

-

-

-

... More
od115953/2022_2023 : "Core Switch (Layer 3) Manageable with following components<br>Chassis with minimum 512 Gbps Back Plane Module, Throughput Aggregate Min. - 90 Mpps, Should support at least 48 ports (1000 Base-TX) and minimum 2 Nos of 1000 Base- SFP / 10 GBASE SFP+ ports, Redundant Power Supply & Fan, and other required accessories and Management Module.<br>POPULATED WITH<br>1 nos of populated SFP, 1000Base LX, LC connector<br>with Multi Mode LC-LC Duplex Patch cords to connect to LC Couplers in the LIU provided <br>Minimum 48 numbers of Populated 10/100/1000 Mbps RJ 45 ports<br>"<br>

1

-

-

... More
od146395/2023_2024 : Access Switch (Type B)- (Layer 2 or higher) PoE Switch (Managed)<br>with following components<br>minimum 72 Gbps Back Plane<br>24 nos of 10/100/1000 RJ 45 + 2 unpopulated SFP Ports, option slot<br>for 10 Gbps module ; 1 AC PSU

6

-

-

... More
SUPPLY OF TELEPHONE INSTRUMENTS:-

-

-

-

... More
od115956/2022_2023 : Basic telephone instrument

52

-

-

... More
od115957/2022_2023 : Supply of display telephone Instruments

3

-

-

... More
EPABX

-

-

-

... More
od115959/2022_2023 : 200 Port EPABX with 4 CO Trunks, 8 Digital Extension Circuits, 48 Analogue Extensions circuits, 1 No. OP. Console with min. 24 DSS buttons & 4 port IVRS<br>

1

-

-

... More
UPS System (Only for Servers)

-

-

-

... More
od115960/2022_2023 : 10 + 10 KVA (PRS) UPS system with 20 nos SMF Battery 150 AH backup for each UPS for 2 Hrs including supply of battery rack <br>

1

-

-

... More
CONDUITS

-

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

1045

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

1440

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

100

-

-

... More
od146409/2023_2024 : Lubricated HDPE Pipe for Incoming Service Provider Cable (32 mm<br>ID) as per TEC specification G/CDS-08/02 November 2004 / IS<br>4984-1995.

80

-

-

... More
od146410/2023_2024 : Fluke Testing and Certification for CAT6A with Min. 20 Year<br>warranty

1

-

-

... More
od146411/2023_2024 : WIFI<br>Wireless access points 802.11ac MIMO (IEEE 802.11ac) with a<br>coverage radius of Min. 25 Mtrs.

2

-

-

... More
od146412/2023_2024 : Supply and installation of MS POWDER COATED (GREY<br>COLOUR) Raceways of 1.6 mm thickness with cover in ceiling and<br>shafts, floor etc with complete MS supports fabricated per site<br>requirements. It should also include the cost of bends, tees etc as<br>required.<br> 150 x 60 x 1.6 mm thick

105

-

-

... More
od146413/2023_2024 : 100 x 60 x 1.6 mm thick

104

-

-

... More
od146414/2023_2024 : RoHS 2011/65/EU Compliant<br>RG11 Co-axial cable with<br>Foam Insulated Dilectric<br>copper / copper clad steel inner conductor<br>Aluminum braid shield + foil shield<br>less than 10 dB loss at 3000 MHz

30

-

-

... More
od146415/2023_2024 : RoHS 2011/65/EU Compliant<br>RG6 Co-axial cable with<br>Foam Insulated Dilectric<br>copper / copper clad steel inner conductor<br>Aluminum braid shield + foil shield<br>less than 13.5 dB loss at 3000 MHz

30

-

-

... More
od146416/2023_2024 : Supply and installation of Tap -off with suitable PVC / GI Modular<br>Back Box etc. in recess / surface mounted including necessary<br>connections with all accessories required for complete installation as<br>directed by the Engineer in charge. (Power pass - one ports)<br>less than 3 dB loss for 2400 Mhz through port 4 way

1

-

-

... More
od146417/2023_2024 : Council hall audio system for 48 microphone including 1 numbers<br>Tie in mike,1 number handheld wireless mike, mixer/pre amplifier<br>and 100w power amplifier with LMT support

1

-

-

... More
od146418/2023_2024 : 25W LMT speaker

4

-

-

... More
od146419/2023_2024 : 2 core 1.5 sq mm armoured cable

55

-

-

... More
APPENDIX-K Electrical Work) -HT Part - HT Cables, END Terminations

-

-

-

... More
od365621/2021_2022 : Supplying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size 3core 300sq mm.

100

-

-

... More
8.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm

100

-

-

... More
10.5.4 : Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm

1

-

-

... More
10.4.4 : Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm

3

-

-

... More
7.9 : Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

10

-

-

... More
od114462/2023_2024 : Fabrication, supply, and erection of 2 pole structure with necessary accessories made from 175x85 mm RS joist, 100x40mm M.S. channel, clamps, nut, bolt etc., as per Inspectorate standard with the following items (Including Civil works). a. Supply and fixing of the following items on the above DP structure b. 11kV gang operated AB switch 1 Set c. 11KV 9KA lightning arrestor 3 Nos d. 11KV DO fuse with fuse rod 1 Set e. 11KV pin insulator with pin 6 Nos f. 11KV disc insulator 6 Nos g. Supply and laying of "0"; SWG copper wire for interconnecting the above items 35 Mtr h. Fabrication, supply and erection of gate made from 12mm square rod with 40x40x6mm MS angle etc., as per Inspectorate standard (Including Civil works) 1 Set i. Fabrication, supply and erection chain link fencing made from 2"", 12 Gauge chain link, 50x50x6mm MS angle etc., as per Inspectorate standard (Including Civil works) 1 Set j. Supply and providing 38mm GI pipe earth electrode as per standards 2 Nos k. Supply and laying No.8SWG Cu. Wire as earth conductor Details to be as shown in SLD

1

-

-

... More
od114489/2023_2024 : "HT Metering Panel with Load Break Switch<br>Supply, installation, testing and commissioning of HT metering Panel with 630A Load Break Switch with HT fuse and Earth switch, Bidirectional TOD meter accuracy class 0.2s (with RS485 communication facility), CTs(0.2S) and PT(0.2) , HT fuses, test terminal block, control fuses,etc. The Panel shall be made out of 2mm thick CRCA sheet steel, totally enclosed, IP 66 with canopy,weather proof, undergone seven tank process with powder coated finish. The Panel should have seal Off bushings, space Heater with thermostat, 630A Copper busbars and support insulators, provision for earthing, all mounting accessories as required complete as per the requirement of Kerala State Electricity Board. The metering cubicle shall have glass window for meter reading.<br>Details to be as shown in SLD "<br>

1

-

-

... More
Transformer

-

-

-

... More
od138250/2023_2024 : "Supply,Installation, testing and commissioning of 160KVA Unitised Substation comprising 160KVA, 11KV/433V, 3 phase, Vector DYN- 11, AN cooled, cast resin complete with enclosure IP42 and low loss core with Off load tappings from +5 % to -5 % in steps of 2.5 %, with WTI & LV terminals suitable for connecting HV cable of 1x3x300 sq mm and LT cable of 1x3.5x185 sq mm. XLPE cable with all other standard fittings and accessories confirming to IS: 1180 (Losses as per ECBC 2018, Loss at 50% loading - 1500W , Loss at 100% loading- 3800W ). 11kV, 630A 25kA LBS with 10A fuse for isolation. <br>320A 4P,36kA MCCB with isolation duty and 1 E/F release at LT side as shown in schematic drawing."<br>

1

-

-

... More
od365648/2021_2022 : Supply, Installation of neutral CT of ratio 60/5A, class 5P10 15VA of accuracy for earth fault relay in a metallic enclosure including control wiring from the transformer.

1

-

-

... More
od365656/2021_2022 : Supply, Installation, testing and commissioning of emergency isolation push button mounted in standard I.P 65 weather proof break glass enclosure to isolate the power Supplying to the building in case of emergency when the face glass is broken. The push button shall be connected to the trip coil of the 11 kV LB SFU using 1.5 sq.mm 2 core copper cable.

1

-

-

... More
od365659/2021_2022 : Supply, Installation, testing and commissioning of easily detachable neutral link fabricated out of 25x3mm tinned Cu strip of minimum length 150mm suitably bolted at both end and inserted in the neutral earthing conductor from the transformer bushing.

1

-

-

... More
Diesel Generator

-

-

-

... More
od365669/2021_2022 : Supply, Installation of neutral CT of ratio 50/5A, class 5P10 15VA of accuracy for earth fault relay in a metallic enclosure including control wiring from the DG.

1

-

-

... More
od138363/2023_2024 : Supply, Installation, Testing and Commissioning of 125 kVA prime rated D.G set with acoustic enclosure and control panel, protection and digital metering, controls and interlocks, CT's and transducers for all metering and protection with suitable size breaker, including antivibration mountings, exhaust silencer and exhaust piping in suitable stack including MS support conforming to latest environment protection regulations for emission and noise levels, water/coolant cooled, ( radiator type) four stroke, electric start conforming to BS: 5514 , brushless, self excited, self regulated and suitable for continuous operation at 1500 RPM, generating 415 V +/- 5% Volts at 0.8 p.f (lag),50 Hz, 3Phase, 4 wire system generally conforming to IS 4722. Both Engine and alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads, battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards, Inbuilt Fuel tank suitable for 8 hrs continuous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size of cable termination box etc.as required and as per specifications. Rate shall be inclusive of exhaust pipe as per the detailed technical specification. The work should be as per Electrical Inspectorate / pollution control board standards.<br>

1

-

-

... More
Panel Boards, Enclosures, Accessories

-

-

-

... More
od365679/2021_2022 : APFC PANEL<br>Adequate forced ventilation arrangement shall be provided by means of a cubicle type fan of capacity 225 m3/hr also with contractor thermostat control. Control fuses shall be provided for the fan circuit. Lamp indication shall be provided to indicate the working/ non- working states of the fan.<br>The capacitor compartment shall be so constructed that in case of any capacitor failure, fluid leakage or fumes from the field capacitor shall not affect the capacitors in the other compartments. The inter-compartmental partition of capacitor chamber shall be perfectly done. The capacitor shall be rated for a voltage 480 V or above and conform to IS - 2834.<br>Incoming <br>a)1 No 100A TPN Isolator<br>b)1 Set RYB Indication Lamp<br>c)6 Nos 2A SP MCB 10kA<br>d)3 Nos 100/5A CL:1,15VA CT<br>e)1 No. (0-100)A Ammeter with Selector Switch<br>f)1 No. (0-500)V Voltmeter with Selector Switch<br>g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF<br>Outgoings<br>a)2 Nos. 32A TPN,10kA MCB<br>b)2 Nos. 25A TPN,10kA MCB<br>c)1 No. 16A TPN,10kA MCB<br>Capacitor:<br>10kVAR Capacitor Duty Contactor - 2 Nos<br>7.5kVAR Capacitor Duty Contactor - 1 No<br>5kVAR Capacitor Duty Contactor - 1 No<br>2.5kVAR Capacitor Duty Contactor - 1 No<br>10kVAR Heavy Duty Capacitor Box Type Resin Filled -2 Nos<br>7.5kVAR Heavy Duty Capacitor Box Type Resin Filled -1 No<br>5kVAR Heavy Duty Capacitor Box Type Resin Filled -1 No<br>2.5kVAR Heavy Duty Capacitor Box Type Resin Filled - 1 No<br>7% detuned reactor – 5 nos.<br>4 Stage APFC Relay - 1 No<br>Complete with all Control Wiring Components such as Control Contactors, Selector Switch, Push Button with Elements, Control MCB's etc. as required<br>Details to be as shown in SLD.<br>

1

-

-

... More
od365683/2021_2022 : LIFT PANEL<br>Incoming <br>a)1 No 50A TPN MCB<br>b)1 Set RYB Indication Lamp<br>c)3 Nos 2A SP MCB 10kA<br><br>Outgoings<br>a)1 No 40A,4P,100mA RCBO<br>b)1 No 25A,DP,30mA RCBO<br>c)1 No 16A,SP,MCB<br>d)3 Nos 6A,SP,MCB<br>e)2 Nos 10A,SP,MCB<br>Details to be as shown in SLD.<br>

1

-

-

... More
od365685/2021_2022 : Supply & Installation of Utility Panel<br>UTILITY PANEL<br>Incoming<br>a) 1 No 100A TPN Isolator<br>b) 1 Set RYB Indication Lamp<br>c) 6 Nos 2A SP MCB 10kA<br>d) 3 Nos 100/5A CL:1,15VA CT<br>e) 1 No. (0-100)A Ammeter with Selector Switch<br>f) 1 No. (0-500)V Voltmeter with Selector Switch<br>g) 1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF<br>Outgoings<br>a) 2 Nos 50A,10kA TPN MCCB, Thermal Magnetic Release<br>b) 4 No 40A,10kA TPN MCCB, Thermal Magnetic Release

1

-

-

... More
od365695/2021_2022 : Supply & Installation of SSB<br>SSB PANEL<br>Incoming<br>a) 1 No 200A TPN Isolator<br>b) 1 Set RYB Indication Lamp<br>c) 6 Nos 2A SP MCB 10kA<br>d) 3 Nos 200/5A CL:1,15VA CT<br>e) 1 No. (0-200)A Ammeter with Selector Switch<br>f) 1 No. (0-500)V Voltmeter with Selector Switch<br>g) 1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF<br>Outgoings<br>a) 3 Nos 100A,25kA TPN MCCB, Thermal Magnetic Release<br>b) 1 Nos 80A,25kA TPN MCCB, Thermal Magnetic Release<br>c) 4 Nos 40A,25kA TPN MCCB, Thermal Magnetic Release

1

-

-

... More
od365696/2021_2022 : MAIN SWITCH BOARD (MSB)<br>Incoming - 1 (KSEB side)<br>a)1 No 320A, 36 kA,4P,MCCB Micro. Processor Release<br>b)1 Set RYB Indication Lamp<br>c)6 Nos 2A SP MCB 10kA<br>d)6 Nos 250/5A CL:1,15VA CT<br>e)3 Nos (0-250)A Ammeters <br>f)1 No (0-500)V Voltmeter with Selector Switch<br>g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF<br>h)1 No Low set Earth Fault Relay(51G).<br><br>Incoming - 2 (DG side)<br>a)1 No 250A, 36 kA, 4P, MCCB Micro. Processor Release<br>b)1 Set RYB Indication Lamp<br>c)6 Nos 2A SP MCB 10kA<br>d)3 Nos 200/5A CL:1,15VA CT<br>e)3 Nos (0-200)A Ammeters <br>f)1 No (0-500)V Voltmeter with Selector Switch<br>g)1 No. of Multifunction Digital meter V,A,F,KW,KVA,PF<br>h)1 No Low set Earth Fault Relay(51G).<br>i) 1 Set Reverse power relay with 3 nos 200/5A,CL:1,15VA CTs and necessary cabling and connection. <br><br>ATS<br>a)1 set. of 250A 4P ATS+ AMF<br>Busbar mounted SPD<br><br>Outgoings<br>a)1 No 160A,36kA, TPN MCCB, Thermal Magnetic Release<br>b)2 Nos 125A,36kA, TPN MCCB, Thermal Magnetic Release<br>c)3 Nos 100A,36kA, TPN MCCB, Thermal Magnetic Release<br>d)1 Nos 125 TPN Isolator<br>e)7 Sets On-Off Indication Lamp with 2A Fuse and necessary accessories.<br>Busbar: 300A,415V,50Hz,4P,36kA,Aluminium.<br>Details to be as shown in SLD.<br>

1

-

-

... More
S&F Enclosures For MCB DB

-

-

-

... More
90.11.1.10 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

4

-

-

... More
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

6

-

-

... More
90.11.1.12 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

3

-

-

... More
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

3

-

-

... More
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

2

-

-

... More
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required

1

-

-

... More
2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

2

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

251

-

-

... More
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

32

-

-

... More
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

50

-

-

... More
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

3

-

-

... More
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

17

-

-

... More
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

3

-

-

... More
2.15.1 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps

8

-

-

... More
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

8

-

-

... More
LT Cabling and Termination - Cables

-

-

-

... More
od365709/2021_2022 : 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable. 3.5CX185 XLPE

90

-

-

... More
od124790/2023_2024 : 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable. 3.5CX150 XLPE

85

-

-

... More
od365712/2021_2022 : 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable. 3.5CX120 XLPE

105

-

-

... More
od365714/2021_2022 : 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable. 3.5CX50 XLPE

40

-

-

... More
od365715/2021_2022 : 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable. 3.5CX35 XLPE

120

-

-

... More
od133911/2022_2023 : .1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable. 4CX25 XLPE

90

-

-

... More
od365743/2021_2022 : KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable.4CX16 XLPE

40

-

-

... More
od365749/2021_2022 : KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable. 4CX10 XLPE

450

-

-

... More
od365785/2021_2022 : KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor<br>cable. 4CX6 XLPE - Cu

55

-

-

... More
od365810/2021_2022 : KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor<br>cable.

245

-

-

... More
od365822/2021_2022 : 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable. 3CX4 XLPE - Cu

240

-

-

... More
od365823/2021_2022 : 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable. 12x2.5 sq.mm Cu Cable & End Termination

85

-

-

... More
od133944/2022_2023 : .1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable. 2x6 sq mm

65

-

-

... More
od127568/2023_2024 : 1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable.3x2.5sq mm

210

-

-

... More
od127569/2023_2024 : 1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable.3x1.5 sq mm

305

-

-

... More
7.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm

175

-

-

... More
7.1.2 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm

658

-

-

... More
7.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)

1121

-

-

... More
7.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

49

-

-

... More
7.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

105

-

-

... More
Termination

-

-

-

... More
9.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)

2

-

-

... More
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)

4

-

-

... More
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

4

-

-

... More
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

12

-

-

... More
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)

6

-

-

... More
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

2

-

-

... More
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

48

-

-

... More
od365871/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 4 sq. mm

6

-

-

... More
od365880/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required4X 6sq. mm

2

-

-

... More
od365882/2021_2022 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4x4 sq. mm

8

-

-

... More
od133982/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.2x6 sq. mm

4

-

-

... More
od133984/2022_2023 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required 3x4 sq. mm

6

-

-

... More
od133985/2022_2023 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.12x2.5sq. mm

2

-

-

... More
od130953/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.3x2.5q. mm

6

-

-

... More
od130954/2023_2024 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.3x1.5sq. mm

8

-

-

... More
Earthing

-

-

-

... More
5.1 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.

5

-

-

... More
od131011/2023_2024 : Providing and fixing plate earth station with 1200 x 1200 x 12.5 mm. C.I. plate earth electrode, water pipe, earthing strips, clamps, funnel, Electrodes etc., excavation in all classes of soil,terminal filling with homogeneous mixture of charcoal and salt and back filling ,construction of Earthpit Inspection Chamber and Heavy duty C.I. Chequered plate for Earthpit Inspection Chamber cover. The rate quoted shall be including the excavation, construction of chamber, CI cover & back filling <br>

11

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

660

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

65

-

-

... More
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)

240

-

-

... More
90.16.3.10 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)

370

-

-

... More
Lightning Protection

-

-

-

... More
od365902/2021_2022 : Providing & fixing of 8mm aluminium round conductor with necessary holders at required interval as specified below: Meets the requirement of IS/IEC 62305: semi-hard (EAlMgSiO5 ) With Parapet Polyamide Holder at every 0.3 meters

110

-

-

... More
od365905/2021_2022 : With Terrace Conductor Fiber Reinforce Concrete Holder at every 1 meters

27

-

-

... More
od365910/2021_2022 : With Down Conductor Polyamide Holder at every 0.5 meters

28

-

-

... More
od132170/2023_2024 : "Providing of Air terminals with accessories as per IS-IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod :<br>Meets the technical specification according to DIN EN 50164-2 <br>Meets the requirement of VDE0185/305(IS/IEC 62305).<br>Suitable for high wind load.<br>System consist of Fang Fix with base and clamp, on the top air terminal is erected.<br>1000-4000mm copper air rod."<br>

2

-

-

... More
od132171/2023_2024 : Providing and fixing of earth stud for reinforcement and earth fixed point material shall be suitable for structural earhing as per IS/IEC 62305.<br>

12

-

-

... More
od132172/2023_2024 : Supply,Installation,Testing and commissioning of diagonal clamp @ every 2 meter ,For reinforced steel and 10mm copper bonded steel down conductor and its necessary accessories<br>

15

-

-

... More
od132173/2023_2024 : Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 20mm with copper bonding thickness of 250 microns with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. Exothermic welded Clamp or Universal Clamp made of SS 304 for clamping. Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound shall be used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. It should be free from hazardous substances. Concrete Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 170mm with a weight bearing capacity of 50KN. The rate quoted shall be including the excavation, construction of chamber, CI cover & back filling.<br>

4

-

-

... More
od132174/2023_2024 : Providing & fixing of Straight Connectors material suitable for conductor for straight Joints if required. Certified Test Reports from govt recognised labs to be furnished.<br>

34

-

-

... More
od132175/2023_2024 : Providing and fixing of Heavy duty PVC conduit of 32mm 2.5m long ducts including the fastening clips.<br>

15

-

-

... More
od132176/2023_2024 : Supply and laying of copper bonded steel solid round conductor 10mm diameter conforming to IS/IEC 62305 with copper coating thickness of minimum 100microns from earth electrode directly in ground as required for interconnecting the earth pits. Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding.<br>

135

-

-

... More
od132177/2023_2024 : Providing and fixing of Cross Connector/T Connector to route vertical down conductor /mesh formation made of stainless steel SS 304 grade/ Aluminium ferrule with necessary screws etc as required. Installed with 4 hexagonal bolts with M8 hexagonal nuts according to (IS/IEC 62305). <br>

20

-

-

... More
od365917/2021_2022 : Providing and fixing of Test joint suitable for 10mm dia copper coated solid steel round conductor with 100 microns of copper bonding (if pure copper conductor 25x3 mm solid tape also can be used) and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm

6

-

-

... More
od365919/2021_2022 : Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length, having a diameter of 20mm with copper bonding thickness of 250 microns with self-coupling peg & bore arrangement with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. Universal Clamp made of SS 304 for clamping. Impact point on the bottom rod for easy insertion. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and noncorrosive to earth rod. The material should have a resistivity less than 0.2 m. It should be free from hazardous substances. The mineral compound is required to have minimum 20 Kg of the total composite. If using chemical compound min 37.5 Kg is required. Polypropylene & Polyethylene Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. Inspection chamber should be of 170mm x 170mm x 190mm with a weight bearing capacity of 50KN and must include plastering, fixing heavy duty CI cover plate having locking arrangement, CI frame painted with bituminous paint, earth pit with yellow paint below the chamber cover, filling with homogenous layer of charcoal, salt & sand, including excavation of earth pit up to permanent moisture level depth and back filling.

6

-

-

... More
od365921/2021_2022 : Providing and fixing of Heavy duty PVC conduit of 32mm 2.5m long ducts including the fastening clips.

12

-

-

... More
od365923/2021_2022 : Providing and fixing of Expansion piece with connector: For equalizing temperature related length changes. Necessary on conductors length at every 20 meters horizontally. Using round conductor 8mm aluminium conductor with L or T Connector: using stainless steel SS 304 grade or same material of air terminal. Quick installation using hexagonal bolt. Conforms to the requirements according to (IS/IEC 62305)

10

-

-

... More
od365926/2021_2022 : Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required.

135

-

-

... More
od365930/2021_2022 : Providing and fixing of Cross Connector/T Connector to route vertical down conductor /mesh formation made of stainless steel SS 304 grade/ Aluminium ferrule with necessary screws etc as required. Installed with 4 hexagonal bolts with M8 hexagonal nuts according to (IS/IEC 62305).

12

-

-

... More
od365951/2021_2022 : Providing and laying copper coated steel solid round conductor 10mm diameter (if pure copper conductor 25x3mm solid tape also can be used) to earth electrode in heavy duty PVC conduit

10

-

-

... More
Wiring and Accessories

-

-

-

... More
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

292

-

-

... More
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

14

-

-

... More
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

192

-

-

... More
od137186/2023_2024 : Wiring for group controlled (loped) light point /fan point/exhaust fan point/ call bell point (without independent switch etc.) by twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.<br>

14

-

-

... More
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

90

-

-

... More
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet

147

-

-

... More
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).

123

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

52

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

52

-

-

... More
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

54

-

-

... More
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

950

-

-

... More
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

3500

-

-

... More
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

2650

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

700

-

-

... More
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

300

-

-

... More
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm

50

-

-

... More
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

136

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

162

-

-

... More
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)

25

-

-

... More
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

147

-

-

... More
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)

16

-

-

... More
1.27.6 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)

8

-

-

... More
od365963/2021_2022 : Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket tout let and 32A modular DP Switch including connections ,painting etc. as required.

2

-

-

... More
od365975/2021_2022 : Supply & Fixing computer points with 3 Nos 3 pin 5.6A Socket with 2No. 5 / 6 A switch with modular front plate and cover on surface/ recess, including providing and fixing suitable size GI boxes, its interconnections etc, as required complete.

14

-

-

... More
Supply and Fixing of Light Fixtures and Fans

-

-

-

... More
od138906/2023_2024 : Supply of light fittings with all necessary accessories made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall or ceiling and giving connections with required length of 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.<br>L1,40W LED SUSPENDED/SURFACE MOUNTED LUMINAIRE <br>

168

-

-

... More
od138907/2023_2024 : L2, 30W SURFACE MOUNTED LED LIGHT, 2FT x 2FT<br>

31

-

-

... More
od138908/2023_2024 : L3,20W SURFACE MOUNTED LED DOWN LIGHT <br>

8

-

-

... More
od138909/2023_2024 : L4,16W RECESSED LED DOWN LIGHT <br>

27

-

-

... More
od138910/2023_2024 : L5,12W RECESSED LED DOWN LIGHT <br>

2

-

-

... More
od138911/2023_2024 : L6,20W RECESSED LED DOWN LIGHT <br>

11

-

-

... More
od138912/2023_2024 : L7,42W RECESSED LED LIGHT, 2FT x 2FT<br>

23

-

-

... More
od138913/2023_2024 : L8,20W LED SURFACE MOUNTED LIGHT FIXTURE <br>

50

-

-

... More
od138914/2023_2024 : L9,16W LED SUSPENDED/SURFACE MOUNTED LUMINAIRE<br>

22

-

-

... More
od138915/2023_2024 : L10,10W LED BULK HEAD LIGHT,IP66<br>

5

-

-

... More
od138916/2023_2024 : ML,8W MIRROR LIGHT<br>

6

-

-

... More
od140536/2023_2024 : Supply, installation ,testing & commissioning of suitable LED Single Arm Pole light fixtures, with maximum system wattage of 50W. complete with all necessary accessories like led drivers, prewired upto a terminal block including necessary accessories,IP 65 ,and connections suitable for operation on 230V, 50Hz AC supply.<br>

3

-

-

... More
90.15.3.5 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III single arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters

3

-

-

... More
90.15.3.6 : Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters

2

-

-

... More
od140537/2023_2024 : Supply, installation ,testing & commissioning of suitable LED Double Arm Pole light fixtures, with maximum system wattage of 50W. complete with all necessary accessories like led drivers, prewired up to a terminal block including necessary accessories,IP 65 and connections suitable for operation on 230V, 50Hz AC supply.<br>

2

-

-

... More
od140538/2023_2024 : Supply, installation, testing & commissioning of suitable LED flood light fixtures, with maximum system wattage of 50W. complete with all necessary accessories like led drivers, prewired unto a terminal block including necessary accessories ,IP 65 and connections suitable for operation on 230V, 50Hz AC supply.<br>

4

-

-

... More
od140539/2023_2024 : Supply, installation,testing & commissioning of suitable Bollard light fixtures, with maximum system wattage of 6W. complete with all necessary accessories like led drivers, prewired upto a terminal block including necessary accessories,IP 65 and connections suitable for operation on 230V, 50Hz AC supply.<br>

2

-

-

... More
od366031/2021_2022 : Installation ,testing and commissioning of LED Wall fittings-Installations testing and commissioning of prewired fluorescent/ LED fittings of all types complete with all accessories, lamps etc .and wiring using 3 runs of 1.5 sq mm FRLS PVC insulated stranded copper conductor cable as required.

290

-

-

... More
od366032/2021_2022 : Installation, testing and commissioning of LED down light fittings on false ceiling with all mounting accessories as required complete including interconnections using 3 runs of 1.5sqmm FRLSH PVC insulated stranded copper conductor as required.

63

-

-

... More
od366034/2021_2022 : Supply, Installation, Testing and Commissioning of 1200mm sweep, BEE5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation :B, 3nos .blades, 30cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215CMM, 350RPM (tolerance as per IS:374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts washers, temperature rise =75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50Hz single phase AC Supply earthing etc. complete as required. (Rate shall inclusive of supply and installation of remote / electronic regulator) (USHA, ORIENT, CROMPTON, or HAVELLS Make)

80

-

-

... More
od366035/2021_2022 : Supply of 250 mm sweep, 900 rpm light duty exhaust fan with metal frame self-opening louvers working on 230 V AC supply complete with all accessories as required.( Orient, Usha ,Crompton ,or equivalent make

21

-

-

... More
1.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

398

-

-

... More
Isolators

-

-

-

... More
od366369/2021_2022 : Supply and Fixing of 63A 4P Isolator with enclosure

4

-

-

... More
od366565/2021_2022 : Supply and Fixing of 32A 4P Isolator with enclosure

7

-

-

... More
od366547/2021_2022 : Supply and Fixing of 32A W/P TPN Isolators with Suitable enclosure

1

-

-

... More
od143496/2023_2024 : 25A DP <br>

2

-

-

... More
od143497/2023_2024 : 16A W/P DP<br>

1

-

-

... More
od143498/2023_2024 : 40A W/P 4P<br>

1

-

-

... More
Miscellaneous

-

-

-

... More
7.10 : Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

8

-

-

... More
od367229/2021_2022 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessary accessories as required 100x50x2mm thick

78

-

-

... More
od367235/2021_2022 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessary accessories as required 150x50x2mm thick

25

-

-

... More
od367263/2021_2022 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessary accessories as required 300X50X2mm thick

21

-

-

... More
od143548/2023_2024 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessary accessories as required 450X50X2mm thick

10

-

-

... More
od143549/2023_2024 : Fabrication, supply and installation of following size of Ladder Type GI cable tray including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M8 threaded rod and all necessary accessories as required 600X50X2mm thick

25

-

-

... More
od367358/2021_2022 : Supplying and fixing of 6mm thick MS chequered plates duly painted. Plates to be<br>cut size as per site requirement

25

-

-

... More
od367362/2021_2022 : Supplying, Fixing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.

2

-

-

... More
od367363/2021_2022 : Supplying, Fixing 9 Littre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, color washing etc. as required.

4

-

-

... More
od367367/2021_2022 : Supplying, Fixing First Aid Chart duly framed and placed in a conspicuous location for clear vision

4

-

-

... More
od367382/2021_2022 : Painting letters or figures of 2.5cm/4.5cm sizes with enamel paint as identification mark to SB, DB, panel board etc as required

500

-

-

... More
od367388/2021_2022 : Supplying and Providing 15" long rubber hand gloves 15 kV

2

-

-

... More
od367393/2021_2022 : Providing ISI marked electrical 11kV.Grade 2mx1mx2mm thick anti-skid insulation mat as per IS: 5424.

25

-

-

... More
INVERTER

-

-

-

... More
od367596/2021_2022 : Supply and installation of 7.5 KVA Inverter with approximately 20 Minutes SMF Battery backup. Battery Make: (Quanta/HBL/Exide), Inverter : APC/ V - guard/Numeric)

1

-

-

... More
od367609/2021_2022 : Supply and installation of 20KVA UPS, 3 Phase in and single phase out with 20 nos 12V,150AH, tubular heat sealed batteries ,2 hours battery back up ,including providing suitable battery rack etc , Make: Battery (Quanta/HBL/Exide), UPS : APC/Riello/Numeric

1

-

-

-

-

-

... More
od367730/2021_2022 : Supply, installation, testing, commissioning of passenger lift with the following specifications<br>QTY : 1 ( ONE )<br>TYPE : PASSENGER AUTO LIFT (10Passengers)<br>GEARLESS MACHINE ROOMLESS<br>LOAD & SPEED : About 680 Kg @1 M/SECl<br>CONTROL : Micro processor Based V.V.V.F.ARD System<br>POWER SUPPLY : 415 Volts, 3 Phase, 50 Cycles, Alternating Current<br>TRAVEL : GR TO 3RD TO M+TERRACE FLOOR<br>About 15.0 Meters<br>STOPS & OPENINGS : 6 Stops 6 Openings ( All Openings on the same side )<br>MACHINE : DIRECTLY PLACED ABOVE HOIST WAY<br>OPERATION : COLLECTIVE SELECTIVE WITH ON/OFF SWITCH<br>HOIST WAY REQUIRED : About 1950 MM WIDE X 1800 MM DEEP Finished Dimensions<br>AVAILABLE : 1900MM W X 2500MM D<br>CAR SIZE : As per our GA ( General Arrangement ) Drawing Approved by the client<br>CAR ENCLOSURE : SS CABIN Finish With Glass Door in cabin [Half Height Glass Door]<br>CAR ENTRANCE Protected by TELESCOPIC HAIR LINE<br>FINISH [Half Height Glass Door] With<br>Infrared Curtain Clear opening about 800<br>MM WIDE X 2000 MM HIGh<br>HOISTWAY ENTRANCES Protected by TELESCOPIC SS HAIR<br>LINE With GLASS DOOR FOR EACH<br>LANDINGS [Half Height Glass Clear opening about 800 MM WIDE X 2000 MM HIGH<br>DOOR OPERATION Power Operated Automatic.<br>DRIVING MOTOR : PMSM (Permanent Magnet Synchronous Motor<br>ELECTRICAL SAFETY DEVICE: <br>a. Mains3 phase limit switch to protect against over travel<br>b. Single phasing preventor with a protection against phase sequence reversal<br>c. Full proof gate locks for landing doors.<br>d. Car gate switch<br>e. Over speed Governor<br>f. Over speed safety device<br><br>SIGNALS: IN CAR : Battery operated Emergency Light, Alarm, Digital floor<br>Adjustable Shelf<br>Indication, Push Button for each floor, On/Off switch,<br>Fan switch,<br>At Landing : UP/ Down Indication, Push Button,<br>Digital car position indicator<br>DRIVING ROPES : Ropes with factor of safety 12 or above<br>CAR VENTILATION : With automatic ON/OFF Fan<br>CAR LIGHTING : LED lighting.<br>LEVELING ACCURACY : Max. as per article 10 of IS: 14665 :2000, Min. +_1m<br>DRIVE : 'FUJI OR EQUIVALENT<br>STAINLESS STEEL SHEETS : 'SAIL / JINDAL / IMPORTED'<br>MILD STEEL SHEETS : 'TATA/ESSAR/IMPORTED<br>FEATURES : OVERLOAD, FLOOR ANNOUCEMENT

1

-

-

... More
od367735/2021_2022 : Fee to be remitted to1. Electrical Inspectorate Department for Approval & Sanction, 2. KSEB for power allocation application fee & processing fee 3.<br>Meters & CTs testing Fee etc. (actual amount incurred for the above items will<br>be reimbursed on production of original documents)<br>Code

1

-

-

... More
PROVIDING FIRE FIGHTING/FIRE ALARM / P A SYSTEM

-

-

-

... More
od1310/2022_2023 : MAIN PUMP : Supplying, installation, testing and commissioning of Electric driven Main Fire Pump Squirrel cage induction motor, TEFC, synchronous speed of 1500 RPM suitable for automatic operation and consisting of following, complete in all respects , as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to flow of 2280 LPM at 48 m head conforming to IS Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.

1

-

-

... More
od1506/2022_2023 : JOCKEY PUMP:- Supplying, Installation , Testing and Commissioning of Electric driven pump suitable for automatic operation and consisting of following : complete in all respect as required. <br>(a) Horizontal type, end suction / mono block pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 180 LPM at 48 m head <br>(b) Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure ,horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.<br>(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. <br>(d) Interconnection with suitable size PVC insulated PVC sheathed armoured copper conductor cable etc as required. <br>(e) Suitable cement concrete foundation duly plastered with anti vibration pads.

1

-

-

... More
od1512/2022_2023 : DIESEL ENGINE DRIVEN PUMP : -Supplying, Installation, Testing and Commissioning of Diesel Engine driven main fire pump suitable for automatic operation complete in all respect as required. (a) Horizontal type, end suction pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg /sq.cm .a highest and farthest outlet at specified flow of 2280 LPM at 48 m. head conforming to IS 5120.coupled to 50 HP, 1500 RPM water cooled with radiator, Diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, Battery with 12 Volts/ electric starting equipment, Diesel tank, exhaust pipe extended up to 1.0 m. out side pump house duly insulated with 50 mm. thick glass wool with 1.0 mm. thick aluminium sheet cladding ,residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Providing and fixing 15 mm dia GI pipe C class for fuel line as required. (e) Suitable cement concrete foundation duly plastered with anti vibration pads. (f) Suitable size External Battery charger and giving connection supply and battery.

1

-

-

... More
od1638/2022_2023 : Supply and providing Class C Heavy Duty MS pipe with all required specials fasteners supports etc. complete of size 150 mm dia

62

-

-

... More
od1644/2022_2023 : Supply and providing Class C Heavy Duty MS pipe with all required specials fasteners supports etc. complete of size 100mm dia

17

-

-

... More
od1658/2022_2023 : Supply and providing Class C Heavy Duty MS pipe with all required specials fasteners supports etc. complete of size 80 mm dia

57

-

-

... More
od1664/2022_2023 : Supply and providing Class C Heavy Duty MS pipe with all required specials fasteners supports etc. complete of size 65 mm dia

48

-

-

... More
od1667/2022_2023 : Supply and providing Class C Heavy Duty MS pipe with all required specials fasteners supports etc. complete of size 50mm dia

51

-

-

... More
od1673/2022_2023 : Supply and providing Class C Heavy Duty MS pipe with all required specials fasteners supports etc. complete of size 40mm dia

12

-

-

... More
od1694/2022_2023 : Supply and providing Class C Heavy Duty MS pipe with all required specials fasteners supports etc. complete of size 32mm dia

68

-

-

... More
od1710/2022_2023 : Supply and providing Class C Heavy Duty MS pipe with all required specials fasteners supports etc. complete of size 25mm dia

560

-

-

... More
od1911/2022_2023 : Supply and laying Class C Heavy Duty MS pipe with all required specials in ground ,providing necessary trench not less than 1M from ground level, providing insulation of the pipe with anti corrosive self adhesive wrapping tape ,refilling trench etc. complete of size 150mm dia

15

-

-

... More
od1916/2022_2023 : Supply and laying Class C Heavy Duty MS pipe with all required specials in ground ,providing necessary trench not less than 1M from ground level, providing insulation of the pipe with anti corrosive self adhesive wrapping tape ,refilling trench etc. complete of size 80 mm dia

30

-

-

... More
od1971/2022_2023 : Supplying , fixing, testing and commissioning of butterfly valve PN 1.6, bronze/Gun metal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095 of following sizes as required. 150MM Dia

8

-

-

... More
od2573/2022_2023 : Supplying , fixing, testing and commissioning of butterfly valve PN 1.6, bronze/Gun metal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095 of following sizes as required. 100 MM Dia

5

-

-

... More
od2590/2022_2023 : Supplying , fixing, testing and commissioning of butterfly valve PN 1.6, bronze/Gun metal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095 of following sizes as required. 80 MM Dia

4

-

-

... More
od2722/2022_2023 : Supplying , fixing, testing and commissioning of ball valve PN 1.6, bronze/ Gun metal seat duly ISI marked complete, conforming to IS 13095 of following sizes as required. 25MM Ball valve.

4

-

-

... More
od2732/2022_2023 : Non return valve-Supply, installation, testing and commissioning of C.I. slim seal type Non return valve with required flanges, nuts and bolts gasket etc. complete 150 mm dia

1

-

-

... More
od2739/2022_2023 : Non return valve-Supply, installation, testing and commissioning of C.I. slim seal type Non return valve with required flanges, nuts and bolts gasket etc. complete 100mm dia

2

-

-

... More
od2741/2022_2023 : Non return valve-Supply, installation, testing and commissioning of C.I. slim seal type Non return valve with required flanges, nuts and bolts gasket etc. complete 80mm dia

2

-

-

... More
od3147/2022_2023 : FIRE BRIGADE INLET:- Supply, installation, testing and commissioning of 4 way Fire Brigade Inlet connection of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arrangement to be connected to wet riser main

1

-

-

... More
od3168/2022_2023 : Supply and providing Yard Hydrant 80mm

2

-

-

... More
od4152/2022_2023 : Providing and installation of Branch pipe of 63 mm dia having Gunmetal/SS body with hexagonal head of 20mm dia nozzle conforming to IS903 with ISI mark

7

-

-

... More
od4159/2022_2023 : Providing and installation of 63 mm dia,15 Mtr long rubber lined woven jacketed hose pipe, type- A (Reinforced rubber lined) of IS-636-1988 complete with necessary instantaneous spring lock type coupling at the ends to match with landing valve / hose pipe / branch pipe with SS male & female couplings (IS:903:1993)

12

-

-

... More
od4233/2022_2023 : Supplying and fixing of hose cabinet fabricated from 2mm thick MS sheet with 6mm thick glazed front glass doors and looking arrangements suitable for accommodate internal accommodate of 2 no. of 15 Mtrs long hose pipe, 1 No. branch pipe, fittings etc. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of PO red externally and white internally and shall be suitably mounted on concrete base

6

-

-

... More
od4235/2022_2023 : Supplying and fixing First-Aid Hose Reel with MS construction spray painted in PO Red drum and brackets, Conforming to IS 884 with up to date amendments, complete with the following as required. (a) 30 m. long 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 25 mm dia stop valve & M.S. Pipe ISI/EN Certificate

6

-

-

... More
od4253/2022_2023 : Hydrant valve - Supply, installation, testing and commissioning of instances pattern stain less steel single Headed Hydrant valve bearing to IS:5290, 63mm oblique type with instantaneous hose coupling adaptor, complete with PVC blank cap single.

6

-

-

... More
od4272/2022_2023 : Supply, installing, testing and commissioning or Air cushion vessel made of mild steel of 8mm thick ,IS 4736-1968 250mm dia with automatic air release cock, 25mm dia drain valve and shutt off. The vessel shall be1200 MM in height etc. Complete

1

-

-

... More
od4309/2022_2023 : Supply and providing pressure gauge 0-15kg/sq. cm 100 mm dia dial type with isolation cock with pipe in the existing system as required

2

-

-

... More
od4321/2022_2023 : Supply and providing pressure switch with IP 32 enclosure protection phosphor<br>bronze bellows as sensing element , SDPT contact system, etc complete

3

-

-

... More
od4330/2022_2023 : Supply, installation, testing and commissioning of 20mm dia Gun metal Air Release valve

3

-

-

... More
od4342/2022_2023 : Supply and providing flow switch with accessories

4

-

-

... More
od4373/2022_2023 : Supply and providing strainer Y type cast iron body of 150mm dia

2

-

-

... More
od4392/2022_2023 : Supply and installation of system controller to control operation of main electrical pump, diesel pump ,pressure station pump, in sequence as per specification consisting of relays, timers ,sensors, annunciation windows ,for fault indication<br>complete

1

-

-

... More
od4393/2022_2023 : Supply and fixing expansion bellows 150mm dia

2

-

-

... More
od4394/2022_2023 : Supply and fixing expansion bellows 100mm dia

4

-

-

... More
od4398/2022_2023 : Supply and fixing expansion bellows 80 mm dia

2

-

-

... More
od4400/2022_2023 : supply and fixing pendent type sprinkler 20mmdia 68 degree Celsius

182

-

-

... More
od4401/2022_2023 : supply and providing flow meter 150mm dia Fedrel make

1

-

-

... More
90.14.1.2 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.

10

-

-

... More
90.14.2.1 : Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.

1.5

-

-

... More
90.14.3.2 : Supply and providing heavy duty 'A' section neoprene gasket in the panel board

15

-

-

... More
90.14.4 : Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)

3

-

-

... More
90.14.5 : Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board

30

-

-

... More
90.14.6 : Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.

1000

-

-

... More
90.14.7 : Supply and providing copper earth bus in the panel board

550

-

-

... More
90.14.28.4 : S & F Motor starters of the following ratings

1

-

-

... More
90.14.28.5 : S & F Motor starters of the following ratings

1

-

-

... More
90.14.28.9 : S & F Motor starters of the following ratings

1

-

-

... More
2.1.1 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N

2

-

-

... More
2.1.3 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N

1

-

-

... More
2.1.6 : Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.200 Amp TP&N

1

-

-

... More
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

3

-

-

... More
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole

2

-

-

... More
od4529/2022_2023 : Supply and fixing LED indicators for all voltage ranges- Blue colour

2

-

-

... More
od4634/2022_2023 : Supply and fixing LED indicators for all voltage ranges- Red, Green, Black, Yellow, Orange colour

7

-

-

... More
od4645/2022_2023 : Supply and providing Multi function meter to read: V, A, F, 3 phase accuracy class 0.5-

1

-

-

... More
90.12.7.15 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

30

-

-

... More
90.12.7.19 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

20

-

-

... More
90.12.7.20 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

20

-

-

... More
9.1.8 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 16 sq. mm (25mm)

2

-

-

... More
9.1.12 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 70 sq. mm (35mm)

2

-

-

... More
9.1.13 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 95 sq. mm (38mm)

2

-

-

... More
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

60

-

-

... More
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

40

-

-

... More
90.16.1.5 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required

40

-

-

... More
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

4

-

-

... More
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

4

-

-

... More
90.16.5.5 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.

4

-

-

... More
od4752/2022_2023 : Supply and providing 25x6mm brass nut and bolt etc. as required

12

-

-

... More
od4768/2022_2023 : Supply and installation of ABC type fire extinguisher 6kg capacity consisting of M.S cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30cm long high pressure discharge hose, nozzle etc

14

-

-

... More
od4779/2022_2023 : Supply and installation of CO2 type fire extinguisher 4.5kg capacity IS 15638 complete with bracket etc

5

-

-

... More
od4782/2022_2023 : Supply and installation of Fire alarm panel 6 zone complete with charger, alarm display, provision for PA system, battery back etc

1

-

-

... More
od4787/2022_2023 : Supply, installation, testing and commissioning of Photo Electric type smoke detector dual chamber dual source with base plate as per site conditions

85

-

-

... More
od4894/2022_2023 : Supply, laying and clamping of 2 core 1.5 sq. mm PVC insulated and PVC sheathed armoured copper cable, using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages, colour washing etc. as required.

950

-

-

... More
od5001/2022_2023 : Supply, installation, testing and commissioning of Electric Hooter as required

9

-

-

... More
od5017/2022_2023 : Supply, installation, testing and commissioning of manual call point break glass type as per standard specification.

9

-

-

... More
od5043/2022_2023 : Supply, installation, testing and commissioning of heat detector dual chamber dual source with base plate as per site conditions

1

-

-

... More
od5055/2022_2023 : Supply, installation, testing and commissioning of PA cum talk back panel 6 zone selector control with controller, power supply, call selector, suitable amplifier unit, 5 mic in put

1

-

-

... More
od5073/2022_2023 : Supply, installation, of PA speaker wall mounting type 6w

14

-

-

... More
od5076/2022_2023 : Supply, installation of talk back field device

9

-

-

... More
od5106/2022_2023 : Supply and wiring with PVC insulated stranded single c ore copper conductor cables for inter connecting the control devices/ equipment including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.5Sqmm single run

460

-

-

... More
od5118/2022_2023 : Supply and providing Fire Escape Route size not less than 350x350mm as required

1

-

-

... More
od5125/2022_2023 : Supply and providing Glow Sign boards of 3mm PVC foam board size not less than 300x100mm as required

1

-

-

... More
od5144/2022_2023 : Supply and providing Assembly point boards of 3mm PVC foam board size not less than 350x350mm as required

1

-

-

... More
od5175/2022_2023 : Supply and providing emergency fire escape lighting system consisting 2 nos LED lamp ,7 AH SMF battery charging unit ,exit sign display etc in MS enclosure

20

-

-

... More
od5212/2022_2023 : Fee to be remitted to Fire & Rescue Service Department for fire NOC ,actual amount will be reimbursed according to the original receipt

1

-

-

... More
od147556/2023_2024 : Supply, Installation, Testing & Commissioning of Mono<br>Perc SPV panels / Modules of rating 540Wp, with<br>necessary accessories. (To produce 50kWp in total)

1

-

-

... More
od147557/2023_2024 : Supply and Installation of GI structure for mounting Solar<br>Modules on roof for the above specified ratings.

400

-

-

... More
od147558/2023_2024 : Supply, Installation, Testing & Commissioning of Array<br>Junction box with all accessories for outdoor usage with<br>weather proof enclosure. Each junction boxes shall be<br>provided with suitable metal oxide varistors ( Mov's) /<br>surge arresters, one fuse, one SPD & one DC Switch per<br>string.

1

-

-

... More
od147559/2023_2024 : Supply, Installation, Testing & Commissioning of DC<br>distribution board with all accessories to connect the Dc<br>power from solar modules to Inverter for outdoor usage<br>with weather proof enclosure. Each connection shall be<br>provided with necessary fuse, SPD & DC MCB per string

1

-

-

... More
od147560/2023_2024 : Supply, Installation, Testing & Commissioning of 50kW<br>string inverters / PCU of continuous power rating with<br>necessary accessories shall be above 100 % of the total<br>array capacity . The inverter box shall be IP65 rated . The<br>maximum power point tracker (MPPT) shall be<br>integrated in the inverter box to maximise energy drawn<br>from the array.

1

-

-

... More
od147561/2023_2024 : Supply, Installation, Testing & Commissioning of A.C<br>distribution panel board (ACDB) to connect the A.C<br>power from inverter to MSB with necessary cabling. 100A<br>MCCB with necessary SPD & R,Y,B indication lamps..

1

-

-

... More
od147562/2023_2024 : Solar Metering Panel :<br>Supply, installation, testing and commisssioning of<br>Outdoor solar metering panel with 100A,36kA thermal<br>magnetic MCCB , 1 Nos 3 Phase 4 wire kWh meter with 3<br>Nos 100/5A CL:0.5s,10VA CT and 3 Nos 2A SP MCB<br>10kA for Solar. The Panel shall be made out of 2mm thick<br>CRCA sheet steel, totally enclosed, IP 66 with<br>canopy,weather proof, undergone seven tank process<br>with powder coated finish. The Panel should have seal Off<br>bushings, space Heater with thermostat, 100A Copper<br>busbars and support insulators, provision for earthing, all<br>mounting accessories as required complete as per the<br>requirement of Kerala State Electricity Board. The<br>metering cubicle shall have glass window for meter<br>reading.<br>Details to be as shown in SLD

1

-

-

... More
od147563/2023_2024 : Supply and fixing of DC cables and necessary connectors<br>between PV modules, junction boxes, DCDB, inverter etc.

700

-

-

... More
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.

200

-

-

... More
od147564/2023_2024 : Supply of Communication cables and connectors for<br>connecting inverters to Modem, Computer etc

100

-

-

... More
od147565/2023_2024 : Supply of lightning protection of structures as per IEC-<br>62305.

4

-

-

... More
od147566/2023_2024 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm<br>dia including accessories, and providing masonry<br>enclosure with cover plate having locking<br>arrangement and watering pipe etc. with charcoal/<br>coke and salt as required.

2

-

-

... More
od147567/2023_2024 : Supply, Installation, Testing & Commissioning of Reverse<br>power flow cut off system for DG power supply line with<br>all accessories

1

-

-

... More
od147568/2023_2024 : Supply and fixing fuse, cable tray, gland, shim,<br>clamp, DC cable tray, solar meter, socket, DC connector,<br>etc as required

1

-

-

... More
od149518/2023_2024 : Labour & transportation-Loading, Unloading,Complete<br>Supervision, Design installation &<br>Commissioning,Liasoning Works,Daily Remote<br>Monitoring, First 5 year AMC

1

-

-

... More
od147570/2023_2024 : Professional charges for co-ordinating with all government statutory bodies <br> like CEIG, local Electricity authority 's, KSEB, other<br>statutory governing authorities for obtaining necessary<br>approvals & sanctions for complete installations including<br>preparation of necessary documents, drawings,scchemes ,<br>submitting certificates and arranging inspection,<br>feasibility study report etc. Receipt for the fee paid/<br>deposited with local authorities in original to be obtained<br>in name of owner.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.