HLL Lifecare Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 23,030Document Cost
₹ 2,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_HLL_460058_3Tender No
HLL/CHO/HCD/PS/ECRPII/CLDTRSTender Authority
HLL Lifecare Limited ViewPurchaser Address
-Website
http://http://www.lifecarehll.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4
sq. mm + 1 X 4 sq. mm earth wire
85.63
-
238.64
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6
Sq.mm + 1 x 6 sq.mm earth wire
30
-
296.94
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution
board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din
bar, interconnections, powder painted including earthing etc. as required. (But without
MCB/RCCB/Isolator)8 way (4 + 24), Double door
1
-
5469.7
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6
way, Double door
1
-
1974.19
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
27
-
237.28
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
1
-
402.7
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.25 amps
2
-
2291.47
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C"
curve DP MCB complete with connections, testing and commissioning etc. as required.
2
-
1008.79
MGP Works
-
-
-
AREA VALVE SERVICE UNIT (AVSU) - 4 gasbrSITC of 4 gas AVSU as required and as specified
under the guidelines laid for Medical gas system, as approved by Engineer HLL
1
-
8633.04
22mm OD X .9mm THIICK Cu PIPEbrSITC of copper pipes manufactured from phosphorous
deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric
outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes
shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with
dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn,
seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to
metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and
conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate
for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic
saddles should have brass screws. as per the specifications and requirements, painting of the pipes
installed as per color code for medical gas system is also under the scope of contractorbr20 mm
15
-
847.18
15mm OD X .9mm THICK Cu PIPEbrSITC of copper pipes manufactured from phosphorous
deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric
outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes
shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with
dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn,
seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to
metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and
conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate
for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic
saddles should have brass screws. as per the specifications and requirements, painting of the pipes
installed as per color code for medical gas system is also under the scope of contractorbr20 mm
50
-
686.18
12mm OD X .7mm THICK Cu PIPEbrSITC of copper pipes manufactured from phosphorous
deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric
outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes
shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with
dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn,
seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to
metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and
conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate
for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic
saddles should have brass screws. as per the specifications and requirements, painting of the pipes
installed as per color code for medical gas system is also under the scope of contractorbr20 mm
3.75
-
497.91
22 mm BALL VALVE (MGPS)brSITC of Line Valves for use in plant rooms and to facilitate the isolation
of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall
be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall
be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full
bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in
copper stub pipes to enable brazing directly into the distribution system using the flux less brazing
technique. A locking device shall be provided to lock the valve in either the fully open or fully closed
position. Line valves shall be located in readily accessible areas of ducts and shafts, however care
should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as
per HTM 2022/HTM 02-01 standards.
2
-
2358.81
15 mm BALL VALVE (MGPS)brSITC of Line Valves for use in plant rooms and to facilitate the isolation
of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall
be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall
be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full
bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in
copper stub pipes to enable brazing directly into the distribution system using the flux less brazing
technique. A locking device shall be provided to lock the valve in either the fully open or fully closed
position. Line valves shall be located in readily accessible areas of ducts and shafts, however care
should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as
per HTM 2022/HTM 02-01 standards
2
-
1438.81
Gas / Vacuum OutletsbrSITC of Gas/Vacuum Outlets with Front loading type terminal outlets designed
to dispense medical gases or an inlet for medical vacuum to the secondary equipment flow meters,
Surgical Tools, Suction regulators, etc. Terminal unit sealed by O ring. The outlets should Quick Connect
Type and gas specificity is accomplished by Diametric indexing / Geometric indexing Should have Push
to IN and press-to-OUT mechanism for probes. Allows plugging of probes from front. Parking Type probe
/ connector Self-sealing valve on disengaging the probe (Quick disconnect) Smooth quite action Non
return valve for on line servicing/ repairing , Indexed to eliminate inter-changeability of gas services,
Color-coded gas specific front plate Flow rate exceeds the requirements of ISO 9170 – 1. Totally leak
proof, safe & easy to operate Configurations possible: surface, flush & Bead-head. The terminal outlets
should comply with ISO and NFPA. Body shall be of one piece brass construction.
15
-
1725
BHP(1.2Mtr) - Providing and Fixing by necessary means of Installation of 1200mm X 600mm Horizontal
BHP having -high strength aluminum section, thickness of aluminum section 3 mm. Aluminum Powder
coated with provision for Gas Outlets-3 No's & Electrical 5/6amps - 4 No.s ,15/16 Amps switch sockets. -
4 No.s each 1 No. of LAN Point and Phone point with proper RJ connectors, IV holder, Monitor stand with
necessary internal wiring using 4 Sq.mm FRLS Cu wire. all relevant QA/QC certificate shall be submitted
prior to HLL Engineer in charge before Installation.
5
-
18776
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.1 or 2 Module
5
-
135.59
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.12 Module
10
-
269.82
X-RAY POINT
-
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/
recess including cutting the wall and making good the same in case of recessed conduit as required.20
mm
46.88
-
98.98
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.4 Module (125mmX75mm)
3
-
340.33
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.4 Module
3
-
164.06
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )25A SP switch with indicator
3
-
264.54
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
3
-
127.85
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated
copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4
sq.mm earth wire
56.25
-
311.86
CIVIL WORKS
-
-
-
Supplying and laying polyester, washable and stain free cloth(Bio-Active fabric washable germ free
suitable for sterile area) curtain system with maximum curtain cloth height 230 cm(top 30 cm white colour
net and 200cm light blue color as per approval) stitching with stiffener tape, pleats, ironing and laying
around each bed using PVC runner with hooks & stopper for hanging/sliding etc. as per the direction of
engineer in charge including conveyance to site, laying in line and level, sealing all cutting in false ceiling
with powder coated MS cup, all leads and lifts including all labour charges etc. complete. (unpleated
length of the cloth measurement will be considered for payment also the bottom and top foldings will not
be considered in cloth measurement)/ supplying and fixing powder coated 20mm dia. GI round tube
hanging support of required length(app. length 1.10m) one end fixing from slab by using 6mm dia
expansion bolt at a distance not more than 2m, c/c down end fixed to powder coated aluminium channel
frame 45 x 20mm x 1mm thick section by using SS screw as per the direction of engineer in charge
including conveyance.
31.5
-
2616.88
Providing and fixing, Horizondal Roller blinds of fabric section with Horizondal pattern, horizondal open
style, Water resistant, Foldable including all frames, hinges, etc all. Complete lead as per direction of
Engineer-in-charge.
17.6
-
2323
Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth
including necessary repairs to scratches etc. complete
75
-
16.75
Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (One or more coat applied
@ 0.90 ltr/10 sqm).
75
-
79.25
EXTENSION OF TELEMEDICINE HUB
-
-
-
Supply, Conveyance and wiring for LAN/WAN system with the following sizes of UTP 4 Pair CAT 6 LAN
Cable, single core cable in surface / recessed medium class PVC conduit / Case 'N' Cap as
requiredbrUTP 4 Pair CAT 6 LAN Cable
40
-
249.77
"Supply and fixing RJ45 Keystone IO jack with cover and face plate, including crimbing/Punching of UTP
4 Pair CAT 6E LAN Cables on both ends with RJ45 Connector. br"br
4
-
376.97
SMART CLASS ROOMbrSupply, fixing, testing and commissioning of the Short though intractive
projector,having Brigtness : white 3400 ANSI, Colour :3400 ANSI Lumens, Contast ratio : 16000:1 with
WXGA Resolution.The shall have Inbuilt 16W speaker. Max intractivity size : 116" with in 4 feet through
writing cum projection board : 90" interactivity , multi touch, surface material : 4mm thik acrylic resin coted
steel sheet, gloss @ 60 degree-17 , core material 8mm thik particle bord, adhesive : rubber based
adhesive backing material : 02mm thick galvinized steel aluminium powder coated frame . Installtion kit
including wall mount 4 feet, 10 mtr power cable , 10 mt vga cable , 10 mtr HDMI cable.br
1
-
143296.56
Additional works
-
-
-
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB
with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP
42/43)
1
-
6555.18
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable,
1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not
exceeding 60cms, making good the damages , colour washing etc. as required.3 core 4 sq mm with
factory made clamp
50
-
280.88
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable,
1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not
exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with
factory made clamp
40
-
439.95
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole and netural
1
-
646.76
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
1
-
981.67
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
996.59
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
3301.62
NEGATIVE PRESSURE WORKS
-
-
-
PRESSURE SENSOR ( Negative pressure room)brSITC of suitable rated negative pressure sensor
with digital display for easy identification. The unit shall be compatible to use in HVAC, Sterile room
domains and easy to operate. The unit shall be made of 304SS or higher for durability. all units shall be
pre approved by HLL Electrical Engineer in charge or Engineer in charge before installation. All QA/QC
certificate shall be submitted to Electrical engineer for approval as required and all works required.
1
-
4983
FIRE DAMPER WITH FUSIBLE LINKbrSITC of Fire damper with fusible link having certified fire
withstand conditions for 2 hours - 4 hours, as per existing guidelines and UL555 testing standards and
having suitable frame size made of galvanized steel of 1.6mm thickness. DAMPER BLADE shall be
single skin and have 3 accurately roll formed longitudinal grooves for reinforcement and proper closure.
etc. complete as required.
1
-
48954
HEPA FILTER - NEGATIVE PRESSUREbrSupply and installation of 1500CFM Flange type HEPA
filters, efficiency not less than 99.99% for particles of size down to 0.3 micron at exhaust system terminal
collars. including all accessories for installation and working etc. complete as required.
1
-
58590
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular /
round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,
supports, etc as per approved drawings and specifications of following sheet thickness complete as
required.brSite fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
9.6
-
2539.6
Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular /
round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,
supports, etc as per approved drawings and specifications of following sheet thickness complete as
required.brSite fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
82.8
-
2174.86
1000 CFM cabinet Type Fresh Air Fan with 20mm ESP.brSupply, installation, testing & commissioning
of Single skin construction Suspended type with min 70% Efficiency, centrifugal forward drive fan and
vibration isolators, , Guard for inspection door , Pre filter of 10 micron and squirrel cage induction motor
EFF1 Grade. Motor with .55KW shall be suitable for 220±10% volts, 50 cycles/second, 1 phase AC
supply, or else any higher or equivalent as approved by Engineer in Charge.
1
-
125255
2000 CFM cabinet Type Exhaust Fan with 20mm ESPbrSupply, installation, testing & commissioning
of Double skin construction Suspended type with 25 mm thick Sandwiched PUF insulation .Forward/
Backward curved fan with min 70% Efficiency, centrifugal fan belt drive and vibration isolators Guard for
inspection door , Pre filter of 10 micron and squirrel cage induction motor EFF1 Grade. Motor with 3.7KW
shall be suitable for 415±10% volts, 50 cycles/second, 3 phase AC supply and also suitable for DOL
normal Starter switch or as approved by Electrical Engineer HLL Lifecare Ltd
1
-
198680
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without
volume control dampers with anti smudge ring and removable core.
6.62
-
8986.91
Civil Works
-
-
-
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special
sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side
inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of
27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5
mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50
mm of required length with nuts & bolts of required size and other end of angle hanger fixed with
intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which
the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips
of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate
channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction,
including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long,
the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm
long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter
channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing
to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing
tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two
coats of primer suitable for board, all as per manufacturer's specification and also including the cost of
making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably
fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding
the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
42.18
-
1514
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements