Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
HLL Lifecare Limited - HLL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Aug 2024
Closing Date3 Oct 2024
Tender Amount₹ 6,70,000
Costs
EMD
₹ 13,000Document Cost
₹ 1,534Tender Fee
Refer Documents
Summary
Civil And Electrical Works For The Renovation Of Library At Kerala State Jawahar Balabhavan, Thiruvananthapuram
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HLL_688217_1Tender No
HLL/CHO/PROJ/EXT/KSJBB/LIBRENTender Authority
HLL Lifecare Limited ViewPurchaser Address
-Website
http://http://www.lifecarehll.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
4.5
-
-
Supplying and fixing new wooden fillets wherever necessary :2nd class teak wood fillets
30
-
-
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
0.04
-
-
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick.
0.36
-
-
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - MechanicallyTreated bars of grade Fe-500D or more
2.87
-
-
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
1.91
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1.91
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
1.91
-
-
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
185.61
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to an give even shade:One or more coats on old work
173.31
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
6.55
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
0.04
-
-
Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood
2.1
-
-
Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood
2.1
-
-
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
6
-
-
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm
4
-
-
Providing and fixing chromium plated brass handles with necessary screws etc. complete:125 mm
2
-
-
Providing and fixing bright finished door latch with necessary screws etc. complete:300x16x5 mm
2
-
-
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
1
-
-
The refurbishment of the current wooden storage cabinets or wardrobes involves removing the existing doors and dividers, repairing them through cutting, painting/polishing, etc., and reattaching the mended doors and dividers. This includes replacing hinges with screws, locks, as needed. It also entails replacing glass panes with wooden trims where necessary, along with rearranging the cabinets as directed by the Engineer-in-Charge.
12
-
-
Conference Table: Wooden conference table is constructed with a minimum thickness of 18 mm pre-laminated post-formed particle board as the desktop. The desktop includes features such as a cable management tray, grommets, etc. The vertical supports consist of continuous full-height particle board providing ample legroom all around. The corners of the table are curved with post-formed edges. Minimum Dimensions: 3600 x 1200 x 750 mm (W x D x H)
1
-
-
Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic.
12
-
-
Machine polishing to mosaic floor to smooth finish, two or more coat, after fixing pits and cracks in mosaic flooring with chips, matching shade pigment with 50% white cement and 50% ordinary cement and fillers. Apply a clear, acrylic-based sealer to the repaired areas to protect the mosaic flooring etc. complete.
180
-
-
Providing and laying in situ waterproofing treatment in traffold sheet roofing with SBM ( Styrene Butadine Membrane) modified 1.5mm thick black finish membrane over sheet roof consisting of first thick coat of oil bound primer primer @ 0.30 Kg per sqm. Application after thorough cleaning of roofing sheet with wire brush ( Min area 30cmx 30cm ) around the J Bolt. Finally finishing with SBM peel off type membrane around the area to be repaired
15
-
-
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
172.8
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
18
-
-
Providing and fixing false ceiling with 7.5 mm thick PVC plain panel board ceiling of approved quality in aluminium frame work with necessary screws etc complete (aluminium frame work shall be paid separately)
172.8
-
-
Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary
C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in- Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ).
207.36
-
-
Providing and fixing 6 mm dia. G I level adjusting hangers ( upto 1200 mm length), fixed to roof slabs by means of ceiling cleats made out of G.I flat 40x3 mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer -in-Charge.
168
-
-
Providing and fixing precoated G.S. profile sheets after dismantling damaged roofing sheets. Dismantling sheet including ridges, hips, valleys and gutters, etc., and stacking the material within 50 meters lead. The New Sheet has matching traffold and minimum 0.50 mm thick , total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 Mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
25
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes
10
-
-
Electrical works
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
10
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
75
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
75
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
2
-
-
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
8
-
-
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
120
-
-
Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required.
4
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1
-
-
Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent
4
-
-
Supply and Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2100 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro, Havells
6
-
-
Supply and Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification.
Luminaire shall be designed to emit at least 1000 nominal lumens and efficacy ofatleast 105 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. For light fittings to be installed in false ceiling, all required cuttings shall be made and damages shall be made good as per the direction of Engineer in charge. Make-Philips, Crompton, Wipro
10
-
-
Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1
-
-
Supplying, conveyance and Installation of 3 blade, 400 mm sweep, 1400 rpm Wall Mount Fan includingbframes and all mounting accessories complete. Recommended Make: USHA/ Havells/ Bajaj / Almonard or equivalent
1
-
-
Dismantling of existing cables, wires including accessories and stacking as per the direction of Engineer in charge.
50
-
-
Dismantling of existing light point, fan point, Exhaust point including wiring and accessories and stacking as per the direction of Engineer in charge.
5
-
-
Dismantling existing switchboard including cover, plate, sockets and switches complete and stacking these as per the direction of the Engineer-in-charge
4
-
-
Dismantling light fixtures including hanging rods accessories complete as per direction of Engineer in charge
6
-
-
Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent
2
-
-
Supplying and fixing RJ45 Outlet including cover plate, Keystone Jack and Gang box supporting, connection etc. as required
3
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1
-
-