HLL Lifecare Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 29,500Document Cost
₹ 2,950Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HCDPS_697492_1Tender No
HLL/HCD/NABH/DHH/TLY-KLM/24-25Tender Authority
HLL Lifecare Limited ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling tile work in floors and roofs laid in cement mortar including stackingmaterial within 50 metres lead.For thickness of tiles 10 mm to 25 mm
23.03
-
-
Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrous China) includingstacking of useful materials near the site and disposal of unserviceable materialswithin 50 metres lead
1
-
-
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/cmalba all complete as per directions of Engineer-in-Charge
1
-
-
EARTH WORK EXCAVATION
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) /manual meansin foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),including dressing of sides and ramming of bottoms, lift up to 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.All kinds of soil
0.65
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
0.52
-
-
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge
3.65
-
-
PCC WORK
-
-
-
Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4coarse sand : 8 graded stone aggregate 40 nominal size)
1.76
-
-
MASONRY WORK
-
-
-
Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cmor nearest available size confirming to IS 2185 Part I of 1979 for super structure up tofloor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
2.7
-
-
Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cmor nearest available size confirming to IS 2185 part 1 of 1979 for foundation andplinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etccomplete
0.55
-
-
PLASTERING
-
-
-
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
45.44
-
-
STEEL WORK
-
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished welded type tubes
83.16
-
-
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.)
33.1
-
-
Providing and fixing M.S. Grills of required pattern in frames of windows etc. withM.S. flats, square or round bars etc. including priming coat with approved steelprimer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
28.8
-
-
ALUMINIUM WORKS
-
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron)
372.96
-
-
For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50micron)
87.6
-
-
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides
135.79
-
-
Providing and fixing glazing in door, window, ventilator shutters and partitions etc with EPDM rubber /neoprene gasket etc. complete as per the architectural drawingsand the directions of engineer-in-charge . (Cost of aluminium snap beading shall bepaid in basic item): toughened glass of 6 mm thickness.
10.9
-
-
Providing and fixing frosted film in the fixed glass etc. Complete as per the directionof departmental officers
10.9
-
-
Providing and fixing 100 mm brass locks ( best make of approved quality ) foraluminium doors including necessary cutting and making good etc. complete
10
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness
2.25
-
-
DOORS AND WINDOWS
-
-
-
Providing and fixing aluminium extruded section body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), withdouble speed adjustment with necessary accessories and screws etc. complete.
11
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:200x10 mm
22
-
-
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm
22
-
-
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed torequired colour and shade, with necessary screws etc. complete.Twin rubber stopper
11
-
-
TILE WORKS
-
-
-
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm infloors, jointed with neat cement slurry mixed with pigment to match the shade of thetiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand):Dark shade pigment using ordinary cement
10.43
-
-
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded andprepolished, machine cut for kitchen platforms, vanity counters, window sills, faciasand similar locations, of required size, approved shade, colour and texture laid over20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated withwhite cement, mixed with matching pigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to give high gloss finish etc. complete at alllevels.Area of slab over 0.50 sqm
6
-
-
Extra for providing opening or required size & shape for wash basin/kitchen sinkin kitchen platform, vanity counter and similar location in marble/granite/ stone work,including necessary holes for pillar taps etc. including moulding, rubbing andpolishing of cut edges etc. complete.
1
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS :15622, of approved make, in all colours and shades, laid on 20 mm thick cementmortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cementand matching pigments etc., complete.Size of Tile 600 x 600 mm.
10.05
-
-
Providing and laying Vitrified tiles indifferent sizes (thickness to be specified bymanufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, in skirting, riser of steps, over 12 mmthick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting thejoint with white cement & matching pigments etc. complete.Size of Tile600x600 mm
1.82
-
-
SCRAPPING AND PAINTING
-
-
-
Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Two or more coats applied on walls @1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10sqm
71.04
-
-
Finishing with Deluxe Multi surface paint system for interiors and exteriors usingprimer as per manufacturers specifications:Painting Steel work with Deluxe MultiSurface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqmover an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand andmanufacture
5.4
-
-
CURTAIN WORKS
-
-
-
Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, withtwo chromium plated brass brackets fixed with C.P. brass screws and wooden plugs,etc., wherever necessary complete:20 mm dia
16
-
-
Curtain fabric weight shall be up to 250-275 (±5%) gsm Composition offabric shall be polyester yarn I.E. 300 denier fast colour sink age shall be(±5%) Weft and warp shall be polyester / cottonpolyester mix. Fabric density Non Transparent Composition Fabric of curtain shall besoft texture, great shading, drape effect and nice dobby. The bracket shall be sidemounted and front mounted as required. Where curtain used as a partition/ longlength, sufficient support from ceiling/Wall should be provided to avoid sagging.Complete as the direction of Engineer in Charge.
33.6
-
-
PLUMBING AND SANITARY INSTALLATION
-
-
-
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983with C.I. brackets and stainless steel plug 40 mm, including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm
1
-
-
Flexible pipe40 mm dia
3
-
-
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approvedquality and colour.Waste coupling 31 mm dia of 79 mm length and 62 mm breadthweighing not less than 45 gms
3
-
-
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mmsingle piece moulded with height of 270 mm, effective length of tail pipe 260 mmfrom the center of the waste coupling, 77 mm breadth with 25 mm minimum waterseal, weighing not less than 260 gms
3
-
-
Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS: 893115 mm nominal bore
3
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer- in- Charge.Concealed work, including cutting chases and making good the wall etc. 15 mm pipe12 Kgf/ cm2
10
-
-
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step PVC solventcement and testing of joints complete as per direction of Engineer-in-Charge.concealed work, including cutting chases and making good the wall etc. 40 mm pipe10 kgf/ cm2
9.03
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China SurgeonType wash basin of size 660x460 mm with single 15 mm C P. brass pillar taps withelbow operated levers ISI marked
2
-
-
SIGNAGES
-
-
-
Design, providing and fixing Digital Printed vinyl signage boards with transparent3mm acrylic Sheet with 4 nos. SS Studs of Size 16" x 10". Complete asper the per the direction of Engineer in charge.
12
-
-
ELECTRICAL WORKS
-
-
-
POINT WIRING
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
2
-
-
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
2
-
-
CIRCUIT WIRING
-
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
25
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
298
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
98
-
-
SWITCH , SOCKET AND METAL BOXES
-
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
67
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
67
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
25
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
25
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
52
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
22
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 25 amps modular socket outlet and 25 amps modular switch, connection etc. as required for split ac points.
3
-
-
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
5
-
-
DB,ENCLOSURE AND ITS ACCESSORIES
-
-
-
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
1
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
4
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
60
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current upto 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A, 4P, 100mA
1
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25A, 2P, 30mA
4
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
3
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
1
-
-
CABLES AND TERMINATION
-
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
18
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
60
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
8
-
-
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
15
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
2
-
-
LIGHT AND FAN FIXTURES
-
-
-
Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
9
-
-
SITC of wall fan, white colour, 5 star rated as per BEE complete with blades, casing, wall mounting accessories etc.
2
-
-
EARTHING PROTECTION
-
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement andwatering pipe etc. with charcoal/ coke and salt as required
1
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)
40
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
30
-
-
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
30
-
-
SPLIT AC
-
-
-
Supply, Installation, Testing and Commissioning of 1.0TR - 3 Star rated Inverter type split AC units , Hi-wall mounted, preferably with anti corrosive / powder coated outdoor units, fitted with hermitically sealed suction cooled energy efficient Scroll / Rotary compressor operating on R-32 / HFC-134a / 407 C / 410 A refrigerant suitable for operation on 220 V, 1 Ph, 50 Hz A/C supply. The units shall be inclusive of all standard accessories like power & control cables, good quality copper tubing of minimum 3 meter length to interconnect the outdoor unit with indoor unit for refrigerant lines, elastomeric Nitrile rubber insulation, clamps etc. Notes: (1) Condenser tubes, Evaporator tubes & connecting pipes should be made out of good quality copper. (2) High-energy efficient compressor of rotary / Scroll type (3) Cordless remote for setting Temp, on time, off time, power saving mode, auto mode operation, sleep mode, auto setting with memory backup, time delay feature, programmable timer, etc. with real time clock. (4) Warranty: 5 Years on PCB, 10 years warranty on compressor and one year warranty for the total system from the date of handing over/ commissioning Make: Blue Star / Voltas / Carrier Midea / Hitachi / Daikin / Panasonic / Mitsubishi / Toshiba / Trane / O General or equivalent
2
-
-
Supply, Installation, Testing and Commissioning of 1.5TR - 3 Star rated Inverter type split AC units , Hi-wall mounted, preferably with anti corrosive / powder coated outdoor units, fitted with hermitically sealed suction cooled energy efficient Scroll / Rotary compressor operating on R-32 / HFC-134a / 407 C / 410 A refrigerant suitable for operation on 220 V, 1 Ph, 50 Hz A/C supply. The units shall be inclusive of all standard accessories like power & control cables, good quality copper tubing of minimum 3 meter length to interconnect the outdoor unit with indoor unit for refrigerant lines, elastomeric Nitrile rubber insulation, clamps etc.
Notes: (1) Condenser tubes, Evaporator tubes & connecting pipes should be made out of good quality copper.
(2) High-energy efficient compressor of rotary / Scroll type
(3) Cordless remote for setting Temp, on time, off time, power saving mode, auto mode operation, sleep mode, auto setting with memory backup, time delay feature, programmable timer, etc. with real time clock.
(4) Warranty: 5 Years on PCB, 10 years warranty on compressor and one year warranty for the total system from the date of handing over/ commissioning
Make: Blue Star / Voltas / Carrier Midea / Hitachi / Daikin / Panasonic / Mitsubishi /Toshiba / Trane / O General or equivalent
1
-
-
Supply & installation of Stabilizer suitable for 1.0TR/1.5TR Capacity Split AC units inclusive of all necessary wiring/connection. Stabilizer should comply with the detailed specification mentioned below. Intelligent Time Delay System, Latest IC Technology - Assures reliable protection, Wall Mounting Cabinet Design - Elegant and easy to install, Low & High Voltage cut-off Protection, Built-In Thermal Overload Protection - Protects the stabilizer and compressors during high-temperature burnout, Working Rage Voltage - 170 VAC - 270 VAC Make: V-Guard/Vstab / Microtek or Equivalent with ISI Standard.
3
-
-
Supply and fixing of M.S OUTDOOR STAND for Split ACs. The work involves supply of heavy duty powder coated mounting bracket for outdoor unit with mounting bolts, complete as required and as directed by the Engr.-in-Charge
3
-
-
Drain Piping for Split ACs: Supply & installation of PVC insulated piping for condensate drain Including wall chasing, necessary supports, Clamps etc complete as required
20
-
-
Additional refrigerant Copper piping Kit for Split ACs : Supplying and installation of additional refrigerant piping kit consisting of power and control cables, good quality copper tubing, Elastomeric Nitrile rubber insulation etc. for Split AC units.
10
-
-
TOKEN SYSTEM
-
-
-
SITC of Token Dispenser Printer Machine with Battery,Auto & Manual Both Reset Option. Active Screen Dimensions - 8 Inch * 10 Inch
2
-
-
SITC of Wireless Token Display System with English and local language Voice Announcement.Display Type LED,Range 100 Meter In An Open Area Peon Bell Option, Slogans Announcement Features 2.3 Inch Character Height,3 Digits Token Number Display
2
-
-
DOCUMENTATION AND APPROVAL
-
-
-
DOCUMENTATION AND APPROVAL - "Charges for Preparation of all drawings submitting and getting approval from KSEB, submitting of Completion certificates and arranging inspection, getting sanction from KSEB, obtaining power allocation if necessary & power connection etc. for commissioning of the whole installation in the premises. All statutory payments will be reimbursed on production of the original receipts
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%