HLL Lifecare Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

HLL Lifecare Limited - HLL Tender

Works
Healthcare and Medicine
Eprocure
Opening Date10 Apr 2025
Closing Date18 Apr 2025
Tender Amount₹ 2,49,25,224 
Notes
Download

AI Insights

Technical Capacity
... View More
The required prior work experience for the bidder includes successfully completing similar works during the last five years ending 31st March 2025. The similar work experience can be either of the following: - Three similar completed works costing not less than Rupees 99.7 Lakhs (40% of the estimated cost); - Two similar completed works costing not less than Rupees 124.6 Lakhs (50% of the estimated cost); - One similar completed work costing not less than Rupees 199.4 Lakhs (80% of the estimated cost). Additionally, the bidder should have an average annual turnover of at least 124.6 Lakhs during the last three financial years ending 31st March 2024. For engineering disciplines, a minimum experience requirement is specified: * For a Graduate Engineer or Diploma Engineer in Civil discipline, a minimum of 1 or 2 years of experience is required, respectively. * For a Graduate Engineer or Diploma Engineer in Electrical discipline, a minimum of 1 or 2 years of experience is required, respectively. * Diploma holders with a minimum of 10 years of relevant experience can be considered equivalent to Graduate Engineers. The bidder should also have an available un-utilized Credit Limit of at least 20% of the estimated cost put to tender. Copies of Work orders and satisfactory work completion reports issued by the Client/Authority concerned shall be submitted in proof of the same.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SITC of recessed 32W LED peripheral lighting of size 300 x 600 mm with optical antiglare system for adjustable light distribution and suitable for clean room application, Luminaries cover should be made of highly resistant, disinfectant proof laminated safety glass/acrylic with stylish fine-grained surface. Fittings should be sealed In accordance with the standard IP54

22

-

-

... More
Supply and fixing of HEAVY DUTY M.S OUTDOOR STAND suitable for 3.0TR / 4.0TR Split AC Outdoor units. The work involves supply and fixing of heavy duty powder coated mounting bracket for outdoor unit with mounting bolts, complete as required and as directed by the Engr.-in-Charge

2

-

-

... More
OT ELECTRICAL WORKS

-

-

-

... More
EARTHING PROTECTION

-

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness

0.72

-

-

... More
STEEL WORK

-

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore

20

-

-

... More
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge

141.21

-

-

... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm

1508.02

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2

35

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes

40

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal outer dia pipes

40

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

14.4

-

-

... More
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point

1

-

-

... More
Supply and Installation of OT/Clean Room Parameter System equipped with displaying the following parameters: room temperature , relative humidity & differential pressure ; Instrument supplied should be complete with all necessary sensors, pressure transmission piping and other mounting accessories.

3

-

-

... More
MASONRY WORKS

-

-

-

... More
15 mm BALL VALVE (MGPS) SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.

18

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.

4

-

-

... More
Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plaster board having glass fibre conforming to IS: 2095 Part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with centre borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side , having as NRC ( Noise Reduction Co efficient) of 0.79, with 50 mm resin bonded glass wool backing.

329.8

-

-

... More
Providing and fixing square rain water gutter pipes including jointing.<br>150 mm diameter

40

-

-

... More
CABLE SUPPLY AND LAYING

-

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp

20

-

-

... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete.

22.84

-

-

... More
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call boxes of MS Construction in surface/recess with stainless steel chain & hammer assembly Complete with glass and push button etc. as required.

1

-

-

... More
ELECTRICAL

-

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

386

-

-

... More
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above

1.02

-

-

... More
Supply, installation, testing and commissioning of Cat6 16 port patch panel, fully loaded, with all accessories required at site to complete the work as per technical specification

1

-

-

-

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

3.99

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

12

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 4 x 10 sq. mm

51

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)

576

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

20

-

-

... More
SWITCH , SOCKET AND METAL BOXES

-

-

-

... More
Supply Installation Testing & Commissioning of Unidirectional Laminar Air Flow (L.A.F) Plenum of Size : 2400 X 1800 mm (8'x6'), constructed out of 1.2 mm thick SS 304 sheet with provision/cutout for mounting the swivel light set. The Plenum shall be covered with H13/H14 grade HEPA filters for unidirectional flow across the surface. On the bottom side, a perforated tablet-type stainless steel grill shall be provided as a cover. The cover shall be easily removed when required. The Plenum shall have a differential pressure port for measuring the pressure drop across the HEPA filters. The casing of the HEPA filter shall be made of aluminum, the media of microfiber glass paper, and the bonding of PU resin. Fins shall be aluminum fins—blended type. A polyethylene gasket shall be provided. The pressure drop shall be within 25 mm WC. Performance efficiency shall be 99.997%, and the grade shall be H13/H14 & penetration—0.3 submicron. The suspended laminar air flow (LAF) shall provide ultra-sterile Class 100 clean air and shall be designed to meet Class 5 of ISO 14644-1 standards.

3

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 25 amps modular socket outlet and 25 amps modular switch, connection etc. as required for split ac points.

2

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

17

-

-

... More
PANELS

-

-

-

... More
Supply Installation Testing & Commissioning (SITC) Ceiling panels of 50 mm thickness having composite construction of two skins both sides with 0.8 mm thick SS 304 sheets and core consisting of rigid polyurethane foam, which has been injected under high pressure with a minimum density of 40Kg/Cum. The individual wall panels shall use the tongue and groove technology for joining two panels, no welding shall be allowed. There should be minimum possible cavity/gap in between the solid and Panels. The total distance between the inside and outside surfaces of the operating room should be variable to suit the architects’ layout, but should be sufficient for the flush mounting of equipment. All joints should be filled with metal filler and sanded flush on site, ready to receive the anti-bacterial paint finish. Wall panel joints should be invisible after the final wall coating is applied. All the sharp edges and corners should be chamfered to avoid bacteria contamination. The panels used for construction should be of maximum possible sizes to reduce joints inside the theatre. The wall panel design and construction should allow for the installation and support of all equipment with provision of openings required for repair and maintenance without affecting rigidity and strength. All wall mounted equipment should be flush-mounted and sealed into theatre wall by means of durable sterile jointing system. The internal surfaces of the room walls should be sprayed with water based non reflective Anti-Bacterial Coatings, wall glaze or equivalent, colour approved by the client, to a minimum dry film thickness of 300 microns. The Anti Bacterial Coatings should overlap the floor covering, ceiling system and doorframes by 25mm to provide a continuous sealed surface. This coating should be water resistant, should not support bacteriological or fungicidal growth and is resistant to most chemicals commonly used in hospital departments. It should neutralize micro organisms which come into contact and should prevent colonizing or sporing of micro-organisms. The sterile coating should remain unaffected by radiation, its anti microbial system should not leach out & its anti-microbial properties should last for a minimum of 3 years. The sterile coating system should be easily maintained and should withstand repeated cleaning with alkaline detergents, antiseptics and fumigation agents without any degradation to the surface finish or performance. Chamfered edge corners shall be provided in the vertical corners to avoid 90 degree joints to ensure sterility. Panels should be capable of openings for additional electrical outlets, x-ray viewers, etc and should be cut easily also later on to add Panels. Panels shall be free from scratches & dents, resistant against humidity and cleaning detergents. Panels shall be self-standing high pharma clean room type meeting relevant EN / DIN Standards. In every operation theatre, one wall should be provided with suitable approved design embedded in glass panel of minimum size 2.4 x 3 mtr. Rates for the same shall be included in the quoted rate. IMPORTANT NOTE: The contractor to take utmost care for transport, shifting and erecting complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-In charge. Note: Necessary cut opens to be made for service outlets and finished after passing the service outlets. The rate inclusive of materials, labour, paint, wastage, chamfering and whatever needed for the SITC of paneling, nothing shall be paid additionally. Approx wall area 3m x 3m = 9m Sqm. Add Wastage 5% = 9.45

116.1

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

120

-

-

... More
Supply, installation, testing and commissioning (SITC) of 11.0TR capacity TWIN Circuit air cooled inverter type Outdoor condensing unit with single/multi scroll compressor as per specifications complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll compressor, electronic microprocessor pendant controller with digital display, first charge R407C/R410A refrigerant gas, vibration isolator pads and saftey devices like thermal protector, pressure relief valve, over load relays single phase preventor, high-low pressure cut out, suitable for three phase 440V Supply.

3

-

-

... More
Supply,Installation,Testing &Commissioning of CAT6 Patch Cord with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 2Meter

2

-

-

... More
12mm OD X .7mm THICK Cu PIPE SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.

36

-

-

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

540.61

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp

67

-

-

... More
HVAC WORKS @ PRE OT AND POST OT - FIRST FLOOR

-

-

-

... More
Supply and fixing of 4 Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 2171-1999 external epoxy powder coating with PO Red Shade No. 538 of IS 5, Supplied with standard accessories.

2

-

-

-

-

-

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size. made out of 20 SWG G.I. sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-in-chargeWith clear fire resistant glass panes 6 mm thick of approved brand, having minimum 60 minutes fire resisitance

0.64

-

-

... More
Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters, including fixing with necessary screws etc. complete.Triple strip vertical type

12

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)

10

-

-

... More
Supply, Installation, Testing & Commissioning of 16 Port POE Switch with 24 No's of 10/100/1000 ports GIGA Switch

1

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet

3

-

-

... More
ALUMINIUM WORK

-

-

-

... More
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete

8.87

-

-

... More
CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.

145

-

-

... More
Supply, Installation, Integration and Commissioning of 8 Lines EPABX Intercom System along with krone module as per the direction from Engineer in charge

1

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal outer dia pipes

40

-

-

... More
Double dorm OT light - Supply, Installation, testing and commissioning of double dome OT light with 2,00,000 + 2,00,000 LUX, Field diameter 15-20cm, depth of field 110mm, colour temperature 4300K, colour rendering index 90Ra, intensity control 25-100, type of intensity control by control panel, LED average life50,000 hrs, 56 Nos of LED. Optional function: Shadow Compensation, handheld wireless remote controller; smooth light focus adjustment, mutual control for both lamp head, and other functions for your options. Make: MEDILUX ALPHA B

2

-

-

... More
SIGNAGES

-

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

126

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

3

-

-

... More
MODULAR OT

-

-

-

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

4

-

-

... More
Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.

104

-

-

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair

95

-

-

... More
Supply, Installation, Testing and Commissioning of 11.0TR - 4400 CFM, 100mm E.S.P, Dx type recirculating factory-built AHUs with 2 Stage Filtration, 6-row Dx cooling coil, Double skin AHU made of 40 mm thick panels consisting of 0.8mm Thick Pre-coated GSS on Outside, 0.8mm Thick Aluminium Sheet Inside with factory-injected PUF of minimum 40 Kg/m3 PUF density. AHU should be ceiling / Floor Mounted type along with Thermal Break Aluminium Extruded Profile at Corners and Joints, complete with Plug Fan with VFD, suitable class IE3 TEFC drive motor with IP55 protection suited for 415 plus/minus 10% volts, 50 Hz 3 phase AC supply, minimum two bend GSS/PVC eliminators, cooling coil section with aluminum finned copper tubes, filter section with 50 mm thick metal viscous/washable synthetic type air pre/fine filters (MERV 7 & MERV 14), mixing box, Aluminium VCDs on Fresh air, Return air & Supply air opening, drain connection, 18G Stainless Steel 304 with 19mm NBR Insulated drain pan, necessary vibration isolation arrangement, expansion valve, drier, Dx AHU Kit, Corded Remote Controller, Limits switches for access doors, inspection lamp. UV-C emitters equipped with reflectors to be mounted on the coil surface using removable extruded aluminum frames. The UV-C emitters to be UL certified and capable of producing minimum 254nm wavelength radiation, 7.5 watt/sqft of coil surface area for equal distribution. Heaters (Capacity to be proposed by OEM) to be slip in type tubular heater with step controller to be fitted inside AHU with suitable humidistat, thermostat, Air stat/ Airflow switch and safety thermostat. Heaters to be arranged in two independently operating banks. One bank shall be operated through humidistat and one bank through thermostat. All the necessary incoming power & control cabling, earthing between AHU / Strip heaters and control panel, all supporting GI hangers, ,MS angles, channels nut , bolts, washers etc. necessary for unit installation cost.shall be included in the scope of supply. Fans should be Eurovent/AMCA Certified. AHUs should be Eurovent/AHRI Certified

3

-

-

... More
Additional refrigerant Copper piping Kit for Split Acs (3TR/4TR) : Supplying and installation of additional refrigerant piping kit consisting of power and control cables, good quality copper tubing, Elastomeric Nitrile rubber insulation etc. for Split AC units.

35

-

-

... More
EQUIPMENTS

-

-

-

... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more

102

-

-

... More
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required.

1

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

1.93

-

-

... More
Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore

1

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)

10

-

-

... More
LIGHT AND FAN FIXTURES

-

-

-

... More
Providing and fixing Steel S.S- 304 (D) Door Handle of 450mm(1 Handles) ( best make of approved quality ) for Glass, Wooden or similar doors including necessary cutting and making good etc. complete

4

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)

6

-

-

... More
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge

4

-

-

... More
PCC WORKS

-

-

-

... More
SITC Of Krone Box 10 Pair

1

-

-

... More
Supply, Installation, Testing and Commissioning of Inverter type 4 way cassette split ac units, having nominal capacity of 4.0 TR suitable for operation on Single / Three phase AC supply. The split AC units shall be fitted with hermetically sealed suction cooled energy efficient scroll / rotary compressors working on HFC 134A / 407 C / 410 A / R - 32 refrigerant. Each split type AC unit shall be comprise of outdoor unit and ceiling mounted 4-way cassette type indoor units with sleek outer cabinet. The installation shall be complete with power & control cabling between indoor and outdoor unit, good quality copper tubing, Elastomeric Nitrilie rubber insulation, insulated drain line etc. Power / Control cabling to be provided in PVC conduits. The drain piping from indoor unit shall be terminated outside at agreed drain point. 4 directional airflow cassette type indoor unit shall comprise of, blower that is statically and dynamically balanced and designed for silent operation, the filters shall be synthetic washable media type arranged for convenient cleaning, integrated drain pump etc. Each unit shall include suitable controls like thermostat and complete as required. The full function of the cassette AC shall be operated with cordless remote control unit for setting the temperature, mode, fan speed etc. Outdoor condensing unit shall be finished with powder coating & should include with compressors, overload protection, air cooled condenser coil made out of good quality copper and of sufficient rows deep and of large face area, fitted with a propeller type fan and suitable motor, service valves arrangements, refrigerant filter etc. all housed in a pretreated, powder coated sheet metal cabinet. The unit shall have 1 year full warranty and 3 year warranty for compressor from the date of commissioning / handing over. Make: Blue Star / Voltas / Carrier Midea / Hitachi / Daikin / Panasonic / Mitsubishi / Toshiba / Trane / O General or equivalent

2

-

-

... More
FIRE ALARM SYSTEM

-

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform

1.44

-

-

... More
PLUMBING AND SANITATION WORKS

-

-

-

... More
Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete

24

-

-

... More
Gas / Vacuum Outlets - SITC of Gas/Vacuum Outlets with Front loading type terminal outlets designed to dispense medical gases or an inlet for medical vacuum to the secondary equipment flow meters, Surgical Tools, Suction regulators, etc. Terminal unit sealed by O ring. The outlets should Quick Connect Type and gas specificity is accomplished by Diametric indexing / Geometric indexing Should have Push to IN and press-to-OUT mechanism for probes. Allows plugging of probes from front. Parking Type probe / connector Self-sealing valve on disengaging the probe (Quick disconnect) Smooth quite action Non return valve for on line servicing/ repairing , Indexed to eliminate interchangeability of gas services, Color coded gas specific front plate Flow rate exceeds the requirements of ISO 9170 – 1. Totally leak proof, safe & easy to operate Configurations possible: surface, flush & Bead-head. The terminal outlets should comply with ISO and NFPA. Body shall be of one piece brass construction.

33

-

-

... More
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers

16.95

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

999.26

-

-

... More
Area Line Pressure Medical Gas Alarm ( 4 gases) SITC of Four channel microprocessor controlled alarm for pneumatic & vacuum services with Digital display of line pressure for all the services with factory calibrated pressure sensors. Color coded LED display of line pressure status (High caution normalcaution- low) Audible Alarm for High & Low pressure condition. Test and Alarm Acknowledge (Mute) facility. (Alarm knowledge (mute) time span is programmable from 1 to 60 minutes). Protected programming facility of alarm limits. The electronic circuitry should be such that if the pressure / vacuum in the gas pipeline drops below the present limit, the equipment should give an audio-visual alarm. Visual alarm should remain active even after pressing of “Mute” button. It should come to normal condition only when gas pressure / vacuum return to normal level. Small and compact design. Mounted on a powder coated MS box. Nut & Nipples should be provided for connection with Pneumatic supply complete as required, all QA/QC should be furnished before Engineer (HLL) before installing the system.

1

-

-

... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture

20

-

-

... More
TILE WORKS

-

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board

32.71

-

-

... More
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.40 mm

12

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

60

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)

4

-

-

... More
Supply and fixing of M.S OUTDOOR STAND for Split ACs. The work involves supply of heavy duty powder coated mounting bracket for outdoor unit with mounting bolts, complete as required and as directed by the Engr.-in-Charge

2

-

-

... More
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side

11

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black , cherry / ruby red .Area of slab over 0.50 sqm

0.81

-

-

... More
Providing and fixing up Multiwood Letter of Size 5 Inch Height & Width Proportional, over any surface as per the direction of site engineer in charge. Rate inclusive of labour, adhesives, etc.

40

-

-

... More
Supply Installation Testing & Commissioning (SITC) Wall panels of 100 mm thickness having composite construction of two skins both sides with 0.8 mm thick SS 304 sheets and core consisting of rigid polyurethane foam, which has been injected under high pressure with a minimum density of 40Kg/Cum. The individual wall panels shall use the tongue and groove technology for joining two panels, no welding shall be allowed. There should be minimum possible cavity/gap in between the solid and Panels. The total distance between the inside and outside surfaces of the operating room should be variable to suit the architects’ layout, but should be sufficient for the flush mounting of equipment. All joints should be filled with metal filler and sanded flush on site, ready to receive the anti-bacterial paint finish. Wall panel joints should be invisible after the final wall coating is applied. All the sharp edges and corners should be chamfered to avoid bacteria contamination. The panels used for construction should be of maximum possible sizes to reduce joints inside the theatre. The wall panel design and construction should allow for the installation and support of all equipment with provision of openings required for repair and maintenance without affecting rigidity and strength. All wall mounted equipment should be flush-mounted and sealed into theatre wall by means of durable sterile jointing system. The internal surfaces of the room walls should be sprayed with water based non reflective Anti-Bacterial Coatings, wall glaze or equivalent, colour approved by the client, to a minimum dry film thickness of 300 microns. The Anti Bacterial Coatings should overlap the floor covering, ceiling system and doorframes by 25mm to provide a continuous sealed surface. This coating should be water resistant, should not support bacteriological or fungicidal growth and is resistant to most chemicals commonly used in hospital departments. It should neutralize micro organisms which come into contact and should prevent colonizing or sporing of micro-organisms. The sterile coating should remain unaffected by radiation, its anti microbial system should not leach out & its anti-microbial properties should last for a minimum of 3 years. The sterile coating system should be easily maintained and should withstand repeated cleaning with alkaline detergents, antiseptics and fumigation agents without any degradation to the surface finish or performance. Chamfered edge corners shall be provided in the vertical corners to avoid 90 degree joints to ensure sterility. Panels should be capable of openings for additional electrical outlets, x-ray viewers, etc and should be cut easily also later on to add Panels. Panels shall be free from scratches & dents, resistant against humidity and cleaning detergents. Panels shall be self-standing high pharma clean room type meeting relevant EN / DIN Standards. In every operation theatre, one wall should be provided with suitable approved design embedded in glass panel of minimum size 2.4 x 3 mtr. Rates for the same shall be included in the quoted rate. IMPORTANT NOTE: The contractor to take utmost care for transport, shifting and erecting complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-In charge. Note: Necessary cut opens to be made for service outlets and finished after passing the service outlets. The rate inclusive of materials, labour, paint, wastage, chamfering and whatever needed for the SITC of paneling, nothing shall be paid additionally. Approx wall area 6m x 3m = 18m Sqm. Add Wastage 5% = 18.9

254.12

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire

25

-

-

... More
Dismantling of wash basin/ Sink, closing the pipeline with end cap if necessary, including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead

2

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work above plinth level up to floor five level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)

0.43

-

-

... More
Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metes and below

24

-

-

... More
Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
SITC of 18 W (+/-2) high efficient surface mounted LED square down lighter with white powder coated, pressure die cast aluminum housing, a polycarbonate diffuser and a sleek design of product height not more than 40mm. The luminaire shall have a CCT of 6500 K, CRI80, power factor0.9 and THD 10 %. The luminaire shall be EMI/ EMC compliant. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports shall be submitted. The luminaire shall have a non-integral LED driver with 50,000 burning hours as per L70B50 criteria, ambient temp-0 to 45 o C, 2.5 kV surge protection, and inbuilt electronic driver, luminaire efficacy 110 lm/W including all accessories necessary as required to complete installation.

50

-

-

... More
Supply and fixing of Shock treatment chart duly mounted on a wooden frame with glass on front as required in 2 languages (Hindi & English).

1

-

-

... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps DP Isolator complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar

24.58

-

-

... More
Providing and fixing up Multiwood Letter of Size 7 Inch Height & Width Proportional, over any surface as per the direction of site engineer in charge. Rate inclusive of labour, adhesives, etc.

40

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps

3

-

-

... More
Supply of 4 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 20 W, luminaire lumen output of 2000 lumens, luminaire efficacy 100 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall be made of extruded PC housing, efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. Including all accessories necessary as required to complete installation.

18

-

-

... More
Providing and fixing 100 mm brass locks ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete

21

-

-

... More
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms

4

-

-

... More
POINT WIRING

-

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current breaker with overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required up to25A, 2P, 30mA

1

-

-

... More
Providing and fixing 25 mm X 3 mm copper strip on surface/Cable tray or in recess for connections etc. as required. Rate to include cost of suitable GI clamps SS hardware, making welded joints etc all complete with. No holes shall be drilled to the conductor for clamping purpose

5

-

-

... More
Supply and installation of Fresh Air/ Exhaust Air Louvre of aluminium powder coated with bird Screen as per specifications and drawings.

3

-

-

... More
Supplying and laying polyester, washable and stain free cloth(Bio-Active fabric washable germ free suitable for sterile area) curtain curtain system with maximum curtain curtain cloth height 230 cm(top 30 cm white colour net and 200cm light blue color as per approval) stitching with stifiner tape, pleats, ironing and laying around each bed using PVC runner with hooks & stopper for hanging/sliding etc. as per the direction of engineer in charge including conveyance to site, laying in line and level, sealing all cutting in false ceiling with powder coated MS cup, all leads and lifts including all labour charges etc. complete. (unpleated length of the cloth measurement will be considered for payment also the bottom and top foldings will not be considered in cloth measurement)/ supplying and fixing powder coated 20mm dia. GI round tube hanging support of required length(app. length 1.10m) one end fixing from slab by using 6mm dia expansion bolt at a distance not more than 2m, c/c down end fixed to powder coated aluminium channel frame 45 x 20mm x 1mm thick section by using SS screw as per the direction of engineer in charge including conveyance.

89.7

-

-

... More
Supplying and fixing 40A / 63A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.

10

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/ 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in Charge. (Single / double glass panes and silicon sealant shall be paid separately)<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).

24.3

-

-

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

29.7

-

-

... More
Providing and fixing C.P. brass pillar taps with elbow operated levers ISI marked, 15 mm nominal bore.

4

-

-

... More
Supply,installation,testing and commissioning of control / transmission wiring between Indoor unit and Outdoor Unit. Cable must be routed through PVC conduits. Cable sizing to be as per OEM recommendation.

45

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

912

-

-

... More
28mm OD X .9mm THIICK Cu PIPE SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.

75

-

-

... More
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.

6

-

-

... More
Providing and fixing frosted film in the fixed glass etc. Complete as per the direction of departmental officers

23.2

-

-

... More
SITC of 36 W (+/-2) high efficient surface/recess mounted 600mm x 600mm soft glowing LED luminaire with system light output greater than 3600 lumens and system efficacy 110 lm/W, UGR19. The luminaire must be energy efficient with CRI80, CCT – 6500K, pf 0.95, THD 10% SDCM5, IP20 protection. The luminaire shall be flicker free with a ripple content less than 5 %. The luminaire must be BIS certified and must have LM79 and LM80 reports from NABL certified labs. The luminaire housing shall be made of CRCA and prismatic polystyrene diffuser with high transparency coefficient and a lifetime of 50,000 burning hours as per L70B50 criteria, 2.5 kV internal surge protection, including all accessories necessary as required to complete installation.

38

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)

70.39

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)

4

-

-

... More
Supply and fixing of 6U rack including wall mounting brackets of, Lockable Front Door and Detachable Side Doors, Cable Manger and PDU of 4 sockets, with provision for 2 fans along with accessories complete

1

-

-

... More
Full height glazed partition-supply and fixing of 12mm Toughened Glass using System-45 Frames as per drawing. The Fixed glass to be fixed using BP45 Profiles at Top & Bottom, Side Profiles SP45 at sides. The profile size to be 45x25MM to be fixed on to the floor/wall/ ceiling as per the architect design. H Junction profile to be used at all Glass to Glass vertical joints, 90 Deg L Junction Profiles and T Junction profiles necessary as per design. In case of Glass overall panel MP45 & BP45 Overpanel Profile to be used. In case of Open glass edges EP45 End Profile to be used

6.75

-

-

-

-

-

... More
22 mm BALL VALVE (MGPS) SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.

7

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm

60

-

-

... More
Supply, Installation, Testing and Commissioning of 1.0TR - 3 Star rated Inverter type split AC units , Hi-wall mounted, preferably with anti corrosive / powder coated outdoor units, fitted with hermitically sealed suction cooled energy efficient Scroll / Rotary compressor operating on R-32 / HFC-134a / 407 C / 410 A refrigerant suitable for operation on 220 V, 1 Ph, 50 Hz A/C supply. The units shall be inclusive of all standard accessories like power & control cables, good quality copper tubing of minimum 3 meter length to interconnect the outdoor unit with indoor unit for refrigerant lines, elastomeric Nitrile rubber insulation, clamps etc. Notes: (1) Condenser tubes, Evaporator tubes & connecting pipes should be made out of good quality copper. (2) High-energy efficient compressor of rotary / Scroll type (3) Cordless remote for setting Temp, on time, off time, power saving mode, auto mode operation, sleep mode, auto setting with memory backup, time delay feature, programmable timer, etc. with real time clock. (4) Warranty: 5 Years on PCB, 10 years warranty on compressor and one year warranty for the total system from the date of handing over/ commissioning Make: Blue Star / Voltas / Carrier Midea / Hitachi / Daikin / Panasonic / Mitsubishi / Toshiba / Trane / O General or equivalent

2

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes

6

-

-

... More
VALVES AND ACCESSORIES

-

-

-

... More
CABLE TRAY

-

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1348

-

-

... More
HVAC WORKS @ ANAESTHESIA ROOM AND DR/STAFF ROOM - FIRST FLOOR

-

-

-

... More
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Actuator

6

-

-

... More
AREA VALVE SERVICE UNIT (AVSU) - 4 gasbrSITC of 4 gas AVSU as required and as specified under the guidelines laid for Medical gas system, as approved by Engineer HLL

1

-

-

... More
Supply & installation of Stabilizer suitable for 1.0TR/1.5TR Capacity Split AC units inclusive of all necessary wiring/connection. Stabilizer should comply with the detailed specification mentioned below. Intelligent Time Delay System, Latest IC Technology - Assures reliable protection, Wall Mounting Cabinet Design - Elegant and easy to install, Low & High Voltage cut-off Protection, Built-In Thermal Overload Protection - Protects the stabilizer and compressors during high-temperature burnout, Working Rage Voltage 170 VAC - 270 VAC Make: V-Guard/Vstab / Microtek or Equivalent with ISI Standard.

2

-

-

... More
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required.

18

-

-

... More
Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete.

32

-

-

... More
CABLE TERMINATION

-

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

10

-

-

... More
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.

1483.51

-

-

... More
Additional refrigerant Copper piping Kit for Split ACs : Supplying and installation of additional refrigerant piping kit consisting of power and control cables, good quality copper tubing, Elastomeric Nitrile rubber insulation etc. for Split AC units.

10

-

-

... More
CENTERING AND SHUTTERING

-

-

-

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms

4

-

-

... More
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.

5.79

-

-

... More
Exhaust Fan: Supply of 250mm sweep, 900rpm light duty exhaust fan shutter type white colour, 9" or 10" star rated as per BEE, with its all accessories including mounting as required for complete installation.

6

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

4

-

-

... More
HVAC WORKS @ OPERATION THEATRE - GROUND FLOOR / FIRST FLOOR

-

-

-

... More
NETWORKING

-

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2

30

-

-

... More
SITC of 10KVA Isolation Panel System, should have isolators provided through leakage relays with EN/CE/UL/BIS/FDA/IEC certification. Specification fault detection feature,medical grade Isolation, compact and mountable on wall.

3

-

-

... More
Supply, Installation,testing and commissioning of suitable sized hard drawn copper refrigerant piping(both suction and liquid) including 13mm thick closed cell elastomeric insulation in between indoor and outdoor units as per site conditions

75

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supply, Insulation, testing and commissioning of Aluminium volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.

6

-

-

... More
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall

35

-

-

... More
Supply and installation of outdoor enclosure box shall be IP-rated, manufactured from UV-stabilized polycarbonate or equivalent material, with internal dimensions suitable for housing a 40/63A 4P MCB. The box shall have a robust locking mechanism, cable glands/entries, and a transparent/opaque lid for easy inspection and maintenance. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge. It shall comply with IEC 60529, IEC 61439, and EN 62208 standards, and meet local regulations. The manufacturer shall provide a minimum 2-year warranty and technical supports

3

-

-

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work

20

-

-

... More
Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead

4

-

-

... More
EARTH WORK EXCAVATION

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B

23

-

-

... More
SITC of 450mm sweep wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories including mounting as required for complete installation.

1

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)

20.88

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker with overcurrent protection (RCBO), having a sensitivity current up to 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A, 4P, 30mA

6

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch

71

-

-

... More
28 mm Ball valve (MGPS) SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.

7

-

-

... More
Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs with lettering of size 15x45 cm. Complete as per the per the direction of Engineer in charge. <br>

30

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

6

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm

55

-

-

... More
Providing and fixing CP Waste Coupling for wash basin and sink etc, of approved brand, quality and colour. Waste coupling 32mm dia with precisely designed, corrosion resistance and perfect finish.

4

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C

45

-

-

... More
PVC CONDUITING

-

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

58

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm

76

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore

2

-

-

... More
DISMANTILING AND DEMOLISHING

-

-

-

... More
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in Charge. (Single / double glass panes and silicon sealent shall be paid separately).<br> Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 +/- 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm)

43.26

-

-

... More
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)

40

-

-

... More
Single Arm ceiling pendant - Providing, Fixing, Supply, Installation, Testing and Commissioning Single Arm ceiling pendant with 1000mm long arm having weight carrying capacity of the arm will not be less than 100 Kgs, one monitor shelf and provision for six electrical sockets 6/16 Amp one number data and telephone socket and 8 nos of gas outlets.

3

-

-

... More
OT VALIDATION - Validation of all OT's, as per ISO 14644 norms after commissioning, performing the following tests. • Temperature and Humidity check • Air particulate count • Air Change Rate Calculation • Air velocity at outlet of terminal filtration unit /filters • Pressure Differential levels of the OT with respect to ambient / adjoining areas • Validation of HEPA Filters by appropriate tests.

3

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil

1.67

-

-

... More
COPPER PIPING

-

-

-

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

32

-

-

... More
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.

32.71

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

2

-

-

... More
Supply, laying and testing of Protective layer for Copper piping with woven fibre glass cloth wrapped around copper piping tubular insulation and with foster painting as required and as directed by Engineer in charge .

15

-

-

... More
FALSE CEILING

-

-

-

... More
Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required.

13

-

-

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms

4

-

-

... More
Providing & fixing in position 1000 mm wide , Electrical Insulating Mats as per IS 15652:2006, 2.0mm thick, suitable for 1.1 KV , fire retardant,no effect of acids, alkalies and transformer oils, moisture proof, high tensile strength and texture finish / cloth impression (Anti slip , marking on top) .

1

-

-

... More
PLASTERING

-

-

-

... More
Providing and fixing CP grating of 6mm thick with rim including setting in floor with white cement mortar and making good the floor :125 mm dia

6

-

-

... More
SCRAPPING AND PAINTING

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door

1

-

-

-

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

1423.12

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

175

-

-

... More
Supply and Installation of suitable CPRI approved (IEC 61439 1and 2) AHU VFD STARTER PANEL factory fabricated wall mounted type all including necessary control and Power cable wiring between AHU and Panel. The motor control shall be facilitated by a variable frequency drive (VFD), and the panels shall incorporate controls such as contactors, overload relays (OLR), single phase preventor (SPPR), control switches, MCBs for AC units. Panel shall have 24v AC powersupply for fire interlock.Panel shall have auto/manual selection switch,on off push button and on,off and trip indication lamp etc.Panel shall have the control element features including humidistat, thermostat, air stat/Airflow switch and safety thermostat along with control wiring. The panels shall feature ON/OFF switches with indicators and a bypass DOL/star delta starter for the VFD, along with a manual changeover switch for transitioning between VFD and DOL/star delta starter operations. The fan/blower motor shall be interlocked with heaters (where provided) such that power supply to heaters will be switched ON, only after the blower has been started and run to full (designed) speed. The panel shall have contactors and breaker for the heater banks with required power and control wiring to maintain Temperature/RH% as per inside design condition.

3

-

-

... More
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick

27

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Oxygen Flow meter with Humidifier Bottle - SITC of Flow meter Back pressure Compensated.Flow meter would be accurate gas flow measurement and control within a range of 0-15 liters per minute.It would meet strict precision and durability standards.Flow meter body would be made of brass material. Flow tube and shroud components would be made of clear, impact resistant polycarbonate. The humidifier bottle would be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier would have built in safety valve.

8

-

-

... More
22mm OD X .9mm THIICK Cu PIPEbrSITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.

130

-

-

... More
MULTIWOOD WORKS

-

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. .All work above plinth level upto floor V level

1.02

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall

35

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 185 sq. mm (57mm)

2

-

-

... More
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.

61

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge.All work upto plinth level.

0.14

-

-

... More
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2

35

-

-

... More
Supply installation, testing and commissioning of following single phase to single phase 6KVA UPS with inbuilt battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with 30 min backup battery with, input pf.9, less input current consumption, with input 230V single phase, output 230V single phase , IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency 90% and output power factor 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 6kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30 Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc.

2

-

-

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm

76

-

-

... More
SAFETY MEASURES

-

-

-

... More
Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.

9.45

-

-

... More
Providing and fixing 2 mm anti static seamless conductive Epoxy Flooring (Primer, Screed, ESD Carbonized Coating, Self-leveling Mix Carbonized compound and final coating) for Clean room. The floor should be scratch resistant, fire resistant, chemical resistant, non-corrosive, slip resistant, smooth, anti-fungi, antimicrobial impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. The floor finish should pass over a concealed cove former and continue up the wall for 100mm. The floor should be provided flat to within a tolerance of ±3mm over any 3-meter area. Copper grounding strip (0.05 thick, 50 mm width) should be laid flat on the floor in the conductive adhesive and connect to copper wire of grounding. The connection from copper grid should be brought out uniformly at places to form equipotential grid. A self-leveling compound should be laid prior to lying of the floor finish. One earthing lead should be brought out of from every 150 Sq. ft. area and attaching it to main earthing strip/ground. Finished Floor should be highly durable with resistance to shock, scratch proof and indentation. Corners should be uniformly Coved Up to 10 cm height. The conductive material should be uniformly impregnated as grains. The floor should be inert to body fluids, chemicals, detergents and disinfectants and it should not be affected by temperature variation within the OT. Colour should be uniform, pleasant and matching with ambiance. The floor should have electrical resistance (Point to ground) within 2.5x10 to 2.5x106 Ohms as per NFPA-99/ DIN 51953/ATMF-150 B1 class of fire resistance. The floor should efficiently discharge electric charges up to 2 KV. The floor should not allow build-up of electrical charge beyond 100 volts due to anti static effect. It should fulfill product requirements as per EN649. The corner should not be terminated sharply and concealed cove-former (Aluminium) should be used overlap to a height of approximate and sealed perfectly and uniformly. Self-leveling compounds should be used for this purpose.

116.1

-

-

... More
RCC WORKS

-

-

-

... More
SITC of 5 star rated , BEE certified 28W, ceiling fan with BLDC motor, with super enameled copper wire winding, 230 V, single phase 50 HZ remote control operated fan with 1200mm sweep and 3 blades including all accessories as required with remote and standard length down rod all accessories required for complete installation.

3

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

15

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

1

-

-

... More
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm

108.8

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire

51

-

-

... More
DB,ENCLOSURE AND ITS ACCESSORIES

-

-

-

... More
Providing and fixing panic bar / latch (Double point ) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer -in-charge, all complete.

4

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

58

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm

12

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

20

-

-

... More
Providing and fixing of wall mounted foot operated 2 way handwash sink with back splash (S.S 304 grade top 1.5mm thick and covering 1mm), of overall size 1500mm, 600mm, 950(+500) mm. The rate includes material, carriage, shifting up to 5th floor, placing, labour charges, etc., except tap. the placement as per the direction of engineer in-charge.

2

-

-

... More
Providing and fixing uplasticised PVC connection pipe with brass unions: 45 cm length15 mm nominal bore

20

-

-

... More
NITROUS OXIDE MANIFOLD - 1X1br1+1 Size Nitrous oxide Manifold should be configured with 1 x 1 nos. should be suitable to withstand working pressure of 145 Kg/cm2, along with 2 nos. of high-pressure copper annealed tail pipes with end brass adapter suitable for Nitrous oxide cylinders and manifold.The manifold should be so designed that it should suit easy cylinder changing and positioning. The system should have non-return valves for easy changing of cylinders without closing the bank. The cylinder should be placed with the help of cylinder brackets and fixing chains which shall be zinc plated.

1

-

-

... More
Providing, Fixing, Installation, and Commissioning of Automatic Hermetically Sealing door 1.2 to 1.8m wide, 2.1 to 2.3m height, having high pressure laminate on both sides that could withstand high abrasion, vision panels (300x500mm). High grade aluminium extrusion profile to carry any door weight (till size 2400mm in width X 2400mm in height) with deep indentations to ensure perfect hermetic sealing. The door leaf should have high quality synthetic rubber gasket with long life to ensure hermetic sealing to maintain pressure differential. Air tightness 99.99% at a pressure 100KPa (Test certificate for hermetic sealing with door frame should be provided with pre-despatch documents. The finished door on either side of the door should be perfectly level (maximum permissible difference +1mm). P Door core of 60mm thick built up with 4mm thick HPCL (High Pressure Compact Laminate) skin at both side of the door to provide better strength and rigidity. CFC-free, high density polyurethane puff (density 40 kg/m3), thickness 52mm to provide better insulation. Door core is surrounded by 2.5 mm thick high-grade aluminium extrusion profiles with natural anodizing of 15 microns finish. Epoxy Polyester Powder coated as per RAL colours or SS Finish (matt/ mirror finish) The aero- dynamic design of profiles makes the door ROBUST in its segment league. Gaskets Door blade is made with 3 tier specially designed 3 side heavy duty replaceable EPDM gasket against wall frame. Bottom sealing with 2-tier heavy duty EPDM gasket to flush with finished floor. Stainless Steel 304 grade lever handle on both side of the door blade for smooth and easy door opening and closing. High Quality double glazed flush vision window of Wall Frame High Grade Aluminium extrusion with natural anodized 15-micron finish wall frame profile. This wall frame profile is 3-sided blind fixed with cladding on wall cut-out section from inside and outside of the room. Including Labour, Transportation, Conveyance etc. The door interlock and access control system shall be provided with combination of proximity card based, numerical key pad lock based and push button-based system & foot operating system. The system shall be complete with access logic controllers, door electromagnets, door release foot operating push button, touchless sensor opening & Closure, emergency door release buttons, PC communicator, control and power wiring and cabling and other required accessories, hardware and software. The access control system shall be powered through UPS supply for uninterrupted operation even during mains power failure. The door Electromagnetic Lock shall be suitable for installation on doors/frames. The electromagnetic lock and armature shall be constructed and designed to provide trouble free service. MAKE: METAFLEX/REBBONE/ALTOS or Equivalent

3

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)

46

-

-

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:75 mm

2

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow operated levers

4

-

-

... More
Surgeon Control Panel with Electrical Distribution Board Providing, Fixing, Supply, Installation, testing and commissioning of Fully Touch Surgeon Control Panel( 6 services ) ,mounted flush in the theatre wall along Distribution Board comprising of the following -1 No Day time Clock (Digital) -1 No Lapse Time Clock (Digital) - Hands free telephone -1 No Medical Gas Alarm -1 Set indicator for temperature & humdity display - Peripheral Lighting On/Off with dimming Control.

3

-

-

... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)

535.53

-

-

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:75 mm

12

-

-

... More
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)

2

-

-

... More
Drain Piping for Split ACs: Supply & installation of PVC insulated piping for condensate drain Including wall chasing, necessary supports, Clamps etc complete as required

40

-

-

... More
Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.

12.14

-

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

15.71

-

-

... More
Supply, installation, testing and commissioning of CAT6A Information Outlet, RJ45 with all accessoriesrequired at site to complete the work as per technical specification

9

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall

35

-

-

... More
15mm OD X .9mm THICK Cu PIPE SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.

395

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid

6

-

-

... More
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/ main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.Fire damper

4

-

-

... More
Providing and fixing panelling or Providing and fixing panelled or Making Shelf, Racks, Tables, etc : 18 mm thick Marine Ply wood with 1 mm thick laminate pasted and pressed with adhesive to give a uniform and smooth finish. (Area of opening for panel excluding portion inside grooves or rebates to be measured, no extra shall be paid for making openings, door / window frames and making provisions for electric conduits.) Shades, design, etc. as per the direction of site-in-charge

30.42

-

-

... More
Supply, Installation and fixing- hanging of FACTORY fabricated fire retardant flexible Canvas connection of minimum 150mm width, at outlet of each Ducted Indoor unit with zipper to facilitate temperature measurement. The fabric to be made of Polyester cloth, black PVC coating on both sides along with galvanised steel seam.

6

-

-

... More
Supply of User Phone- Analog phone

2

-

-

... More
SUB PANEL Fabrication, supply, erection, testing and commissioning of floor or wall mounting dust and vermin proof, cubicle type, front operated MV panel board as per IS 8623 CPRI Certified made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic .drawing. The panel shall be with Top/bottom entry to receive incoming and outgoing, all opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. " Incomer- 200A 25 kA FP TM Based MCCB. 200A 415V, 25kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. Necessary interlocking arrangement "Multi function digital LED meters with accuracy class 1, with necessary CT and accessories for measuring Voltage,Current, Frequency, kW, KVA, etc-1 Set RYB phase indicating LED lamps with control fuses and switches - 1 set. Class B & Class C/ Class 1 & Class 2 Surge arrestor device with necessary HRC fuse for protection of same - 1 nos. Outgoings 100A 25kA 4P MCCB thermal magnetic Based - 4 Nos, 40A 16kA 4P MCB - 7 Nos.

1

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)

3.15

-

-

... More
Vacuum regulator with suction bottle - SITC of Single piece wall mounted suction collection & regulation unit With jar capacity of 600 ml each shall be provided at each of the bed side. Jars would be made of autoclavable materials. The units shall be clamped neatly to the wall using suitable clamps

8

-

-

... More
Providing and fixing fire resistant door frame of section 143x57 mm having built in rebate made out of 16 SWG G.I. sheet ( zinc coating not less than 120 gm/ sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer -in-charge (Dash fastener to be paid for separately ).

24

-

-

... More
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)

4.6

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.Nitrille rubber insulation - 25 mm

450

-

-

... More
CURTAIN WORKS

-

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

-

-

... More
Supply, installation, testing and commissioning of U/UTP cable - Category 6A , 4 pair, 23 AWG solid copper conductor, 500 MHz, LSZH - with Fluke Cable Analyser through existing conduits including termination, numbering tags, cable ties, ferrules and all accessories required at site to complete the work as per technical specification

301

-

-

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm

877.63

-

-

... More
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

106.09

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm

633.37

-

-

... More
Providing and fixing of vertical/roller blinds width 100 mm regular quantity made from 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure complete opaquety with zero light transmittance, having suitable coating on exterior, including all fixtures and fittings complete in all respect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by the competent authority.<br> and inclusive of all labour charges.

9

-

-

... More
Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete. .

1

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp

66

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

43.5

-

-

... More
Supply installation, testing and commissioning of following three phase to three phase UPS with inbuilt battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with min 30 min backup battery with, input pf.9, less input current consumption, IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency 90% and output power factor 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 10kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30 Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc.

3

-

-

... More
Supply, Store, installation, testing and commissioning of 22G (0.8mm) Aluminum duct work in Operation theatres of the above Gauge as appropiate with all accessories, supports, jointing materials, flanges complete all inline with SMACNA Standards and in line with the specifications, drawings etc. The system shall be complete in all respects for commissioning.

183

-

-

... More
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

1

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper

32

-

-

... More
Drain Piping for Split ACs: Supply & installation of PVC insulated piping for condensate drain Including wall chasing, necessary supports, Clamps etc complete as required

12

-

-

... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

256.47

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.

422.55

-

-

... More
Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): toughened glass of 6 mm thickness.

30.4

-

-

... More
Supply & Installation of Return Air Cabinet with 10 micron filter , Size : 22"x14" [Inch], Stainless Steel 304 construction and having internal anti microbial coating . Grill to be Stainless Steel 304 grade. The return air cabinets shall consist of an openable grill and shall be cleanable.

12

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps

2

-

-

... More
Supply, Store, installation, testing and commissioning of 20G (1.0mm) Aluminum duct work in Operation theatres of the above Gauge as appropiate with all accessories, supports, jointing materials, flanges complete all inline with SMACNA Standards and in line with the specifications, drawings etc. The system shall be complete in all respects for commissioning.

261

-

-

... More
CIVIL WORKS

-

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

437.75

-

-

... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead

200

-

-

... More
CIRCUIT WIRING

-

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

90

-

-

... More
Dismantling of plumbing pipe lines of 15mm dia to 110mm dia pipes, including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per the direction of engineer in-charge.

27.9

-

-

... More
Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

1

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore

6

-

-

... More
Supply, Installation, Testing & Commissioning (SITC) of hermetically sealed High pressure compact laminate (HPL) sliding or swing door of width 0.8m to 1m width and 2.1m to 2.3m height. The door core should be 40mm thick, built up with 4 mm thick HPL skin on both sides of the door to provide better strength and rigidity. The inner part of the door should be filled with thick pressure injected CFC free polyurethane foam / Iso - Poly of density 45+/-2kg/m3 and thickness of 32 mm. Should be sealed airtight to prevent further ingress of any microbial organism. Door should have 2.5 mm thick extruded aluminium frame with hinge/ sliding profiles as a part of extrusion, concealed type door closed and drop seal to secure integrity of the operating room. Double glazed IG unit with 5mm tempered glass of size 300*300*60 mm, flush finished on both sides with door blade should be provided in the doors. The door material should be of HPL color should match the interior and care should be taken to make the leaf strong and light weight. The finished floor on either side of the door should be perfectly level (maximum permissible difference +1 mm) The rate inclusive of labour, accessories and hardware like SS 304 'D' type handles / push plates and hydraulic door closers, both side key operated locking arrangement, door seal at the bottom & Sides, Stainless Steel kick plates, etc, complete as per instructions of the Engineer-In charge.

3

-

-

... More
DOORS AND WINDOWS

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

46

-

-

... More
Flexible pipe32 mm dia

14

-

-

... More
Supply of 2 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1100 lumens, luminaire efficacy 110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminum section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K, CRI 80, power factor 0.95, SDCM 5, THD 10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. The luminaire shall have flicker content 5% and shall have high and low cut off with auto restart feature, including all accessories necessary as required to complete installation.

9

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire

269

-

-

... More
Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

17

-

-

... More
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp

60

-

-

... More
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS : 3614 (Part - II), tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer -in-charge ( panneling to be paid for separately).

10.08

-

-

... More
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2

40

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.