HLL Lifecare Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

HLL Lifecare Limited - HLL Tender

Works
Electrical and Electronics
Eprocure
Opening Date1 Oct 2024
Closing Date9 Oct 2024
Tender Amount₹ 9,50,000 
Notes
Download

Costs

Summary

Maintenance Works At Electrical Block At Lbsce Kasaragod

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Maintenance works at Electrical Block at LBSCE Kasaragod
Maintenance works at Electrical Block at LBSCE Kasaragod
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
14.83 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.

42

-

2.89

... More
MR Removing Enamel paint and Rusted Metal Surfaces by scrapping with wire brush and sand papering and preparing the surface smooth complete as per the requirement of the engineer in charge.

31

-

20.5

... More
26.31.1 Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer

20

-

135.5

... More
26.32.1 Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).12 mm average thickness.

20

-

351.24

... More
13.66.1 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work

250

-

167.07

... More
14.66.1 Finish walls with Acryllic Smooth exterior paint of required shade:Old work ( Two or more coats applied @ 1.67 ltr/10 sqm) on existing cement paint surface

1100

-

115.39

... More
10.5.1 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces

7

-

5114.67

... More
13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work

250

-

140.37

... More
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work

31

-

219.17

... More
50.6.7.1 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.

4

-

7139.76

... More
13.1.2 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).

26

-

293.67

... More
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete

11

-

329.03

... More
5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

1

-

8427.61

... More
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more

20

-

96.46

... More
11.20.2 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand).Medium shade pigment using 50% white cement 50 % Grey cement

42

-

1275.43

... More
MR Repairing of existing Steel Window shutter, by removing, making good the hinges and locks, Applying Primer etc. and refixing of repaired shutters to existing frames. as required, all complete as per the direction of the Engineer-in-charge.

80

-

163.96

... More
14.6.1 Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)

16

-

1458.81

... More
50.9.15.2 Supplying and fixing 300 mm Aluminium aldrop

3

-

188.93

... More
22.18.1 Providing and fixing APP ( Atactic Polypropylene Polymer) modified prefabricated five layer 2 mm thick water proofing remembrance, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrance manufacture of density at 25C, 0.87 - 0.89 kg/ litre and viscocity 70- 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23C as 350/ 300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80 N. Softening point of membrane not less than 150C. Cold flexibility shall be upto - 20C when tested in accordance with ASTM, D- 5147 The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane.2 mm (for corrugated roof sheets)

35

-

484.82

... More
15.28.1 Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet

17

-

140.78

... More
12.50 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

17

-

724.87

... More
MR Core Cutting of RCC slabs by using mechanical core cutting equipment of the required diameter of the pipe in full depth etc to the satisfaction of the engineer in charge, including all cost and conveyance materials and labour charges etc complete. 110 mm dia core drilling.

8

-

484.35

... More
9.118.1 Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).

3

-

2033.68

... More
17.18.1 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete.10 litre capacity - White

1

-

1155.01

... More
ROAD CONCRETE

-

-

-

... More
2.7.1 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock

36

-

407.09

... More
MRSupply, spreading and proper fixing of low density polyethylene (LDPE) sheet having minimum 500 micron thickness and greater tear strength over compacted and leveled base course by lapping 200mm on all joints including all required as per the instruction of Engineer In Charge.

180

-

66.75

... More
75.8.1.1A Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate:4 course aggregate) laid to required slope as required including compaction, finishingand tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixedin concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)

23

-

7828.21

... More
Wiring

-

-

-

... More
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C

2

-

1154.62

... More
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire

50

-

169.83

... More
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

60

-

194.41

... More
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

5

-

467.8

... More
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

9

-

398.8

... More
MR Dismantling of existing ceiling fan including downrod, accessories, shackles complete and stacking them as per the direction of engineer in Charge.

10

-

112.55

... More
MR Dismantling existing DB including switchgear complete and stacking these as per the direction of the Engineer-in-charge

1

-

690

... More
MR Dismantling light fixtures including hanging rods accessories complete as per direction of Engineer in charge

15

-

34.5

... More
MR Dismantling of ceiling fan and stacking the same along with downrods, accessories as per direction of Engineer-in-charge

5

-

86.25

... More
MCB, DB, MCCB

-

-

-

... More
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

16

-

232.66

... More
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

2

-

970.67

... More
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

3063.1

... More
90.11.1.10 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)

1

-

2843.24

... More
90.11.1.12 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)

1

-

4823.91

... More
Fixtures

-

-

-

... More
MR Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 270 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent

2

-

4135.57

... More
MR Supplying, conveyance and Installation of 3 blade, 400 mm sweep, 1400 rpm Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: USHA/ Havells/ Bajaj / Almonard or equivalent

1

-

2504.7

... More
MR Supply and Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2100 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 20 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro, Havells

10

-

820.53

... More
MR Supplying and providing extra H.G conduit down rod of 19 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.

45

-

229.6

... More
90.3.24.4 Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down rod<br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.1200 mm 2X20W LED Lamp with box type fixture

15

-

2075.92

... More
Earthing

-

-

-

... More
5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

2

-

13759.17

... More
5.8 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

90

-

995.2

... More
5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

80

-

1176.72



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.