Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Harbour Engineering Department - HED Tender
Civil And Construction
Eprocure
Opening Date9 Feb 2024
Closing Date24 Feb 2024
Tender Amount₹ 27,21,955
Costs
EMD
₹ 50,000Document Cost
₹ 2,760Tender Fee
Refer Documents
Summary
General_rurban Mission Unniyal Tr Beach_shyama Prasad Mukherji Rurban Mission Unniyal Tr Beach Stretch Beautification And Park At Niramaruthur Gp Malappuram Dt_general
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HED_657221_1Bid Award Id
ViewTender No
HED/CEHED/TR/1179/2023_6_1_1/1Tender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
2
-
-
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
45
-
-
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
8
-
-
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
5
-
-
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
5
-
-
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
32
-
-
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
10
-
-
OD7005/2023-2024:Supply and Installation of 9W LED Warm light High Efficacy Step Light, with high efficacy LED driver, made of aluminum body perfect for high pedestrian traffic and plant life application. CCT 5700K. Luminaire with nominal voltage of 240V, 50Hz and lumens of 100lumen. Ingress protection of IP 66 or above to prevent from dust &moisture including whether proof box for mounting the luminaire and all fixing accessories ,termination complete as required.
12
-
-
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
10
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
55
-
-
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
50
-
-
1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
3
-
-
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
6
-
-
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
6
-
-
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1
-
-
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1
-
-
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
10
-
-
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
7
-
-
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
6
-
-
1.49:Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
35
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
13
-
-
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
14
-
-
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
10
-
-
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
7
-
-
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
7
-
-
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
610
-
-
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
36
-
-
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
2
-
-
5.5:Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
2
-
-
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
3.9
-
-
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
48
-
-
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
15.58
-
-
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
14.1
-
-
OD4937/2023-2024:Supply and fixing 7/9 W LED ,BC, lamp OSRAM or equivalent
7
-
-
OD4939/2023-2024:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
50
-
-
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
50
-
-
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
24
-
-
OD4946/2023-2024:Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured 1.1kv grade XLPE copper control cable complete.
230
-
-
OD4945/2023-2024:Supplying and making end termination nickel plated single compression brass cable gland for 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
34
-
-
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
4
-
-
OD7083/2023-2024:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 4 sq. mm
8
-
-
OD7084/2023-2024:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm
4
-
-
OD7074/2023-2024:Supply and installation of cable junction box IP 65 for outdoor application (Thermoplastic Poly-poly carbonate) suitable for cable size 1.5sqmm/2.5sqmm ,80x 80x 52 mm CAPE MOdel Abox io25 or equivalent and accessories for cable juction box such as copper terminal set 2.5 sqmm 5 pole 1 no, support for terminals 1 no including fixing the accessories using suitable size stainless steel bolt and nut ,giving connection making good the damages etc complete as required.
5
-
-
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
150
-
-
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
10
-
-
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
217
-
-
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
13
-
-
14.15.1:Supplying and laying of following size owe HOPE pipe .lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
569
-
-
14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
69.08
-
-
90.12.5.38:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 4 sq mm
119
-
-
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
83
-
-
90.12.7.38:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp
20
-
-
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
10
-
-
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
87
-
-
OD4959/2023-2024:Supply and installation of decorative classic LED street lantern of system wattage of 40W, BIS certified with body made of cast and spun aluminum, permanently sealed optical block (IP66) with heat sink and PMMA protector (IK07) fitted with a Vent Plug pressure equalization unit, fixed onto a hinged spun luminium frame, control gear compartment accessed by loosening one screw for tool free opening and closing. Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overall system efficiency of 120lm/W at correlated color temperature (CCT) of 3000K/4000K, colour rendering index (CRI)70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV.
14
-
-
OD4960/2023-2024:Supply,installation, erection and commissioning of Decorative Pole 4 meter height above the ground level made out of GI and cast iron embellishments, having two section, bottom section of minimum 1000mm length with base dia of 114mm following with base made up of cast iron providing aesthetic pleasing having dia of 145mm and upper section of minimum 3000mm with dia of 76mm. The Pole shall have a cast iron reducer at the bottom of upper section joining with base section. The pole shall have base plate of dimension 200x200x12mm and with 4 Nos foundation bolt slot. The pole shall be with inbuilt junction Box and connectors for loop in loop out with suitable cable entry provision. The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Design comply EN40 standard and basic wind speed 169kmph.Pole should hot dip galvanized after 7 tank process to 65 microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coats of epoxy primer and above that it should be given with polyurethane UV resistant coating painted with avg. DFT of 100micron. The complete system should be hot dipped Galvanised and marine grade treated. CAT REF: KESSLEC 4M HDGI RILA POLE WITH BASE PLATE or equivalent
14
-
-
OD5008/2023-2024:Supply and fixing cubicle type dust and vermin proof 300x600x170 mm, (Mi 0400) Hensel make thermoplastic IP 65 junction box with lid including supplying and fixing 2 Nos Hensel make 10 sq. mm 5pole terminal set for phases and neutral in the existing masonry cubicle fixing the following items, including giving connection using 4.0 sqmm, PVC insulated copper wire , drilling necessary holes for termination as well as entry and exit of cable, terminating the earth wire in the earth strip etc complete. All the bolt nut & washer shall be brass. Astronomical time switch with 2 channels - DIN Rail mounted with automatic calculation of sunrise and sunset times for the whole year & Offset for adjusting of sunrise and sunset times, 10-year power reserve, 2 modules (width 35 mm), 2 independent relays having capacity of 10A at power factor= 0.8, rail-mounted astronomical time switch with factory-set time; text-oriented user guidance in the display, city database, automatic summer/winter time changeover, maximum offset +/-120 mins, weekly program plus, elapsed-time counter for light sources, ON/OFF permanent, option for night break selection for energy savings, relays should have external input supply option to override the switching status. Duo Fix screwless terminals, zero cross switching, two-way switch 16A/250VAC; sealable transparent cover &PC programming. 1 No Rail mounting 415V ,9/11A, 3pole , 230V resin cast coil power contactor - 2 No 16A, 10kA ,Single Pole, MCB - 2 No (As Timer bypass) 4A , 415/230V DP MCB C curve - 4Nos
1
-
-
OD5089/2023-2024:Supply and fixing IP 65 HENSEL 1 row 6module KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws.
6
-
-
OD5068/2023-2024:Supplying and fixing HENSEL make KV -thermoplastic circuit breker boxes IP65 with metrick knock out for cable entry, 1 row 12 module size 295x333x129 KV9112 M with PE+N terminals
1
-
-
OD7054/2023-2024:Supply and installation testing and commissioning of customized factory made wall mounting cubicle having adequate size, dust and vermin proof customized single phase metering panel made of thermoplastic poly carbonate enclosure .The enclosure shall be environment friendly ,recyclable ,uv resistant ,halogen and silicon free, anti acid ,anti corrosive ,IP 65 Protected with IEC 60529,fully wired as per latest electrical standards and all necessary accessories,ready to use ( make Hensel or equivalent) with incomer 63 A DP MCB -1 no, out going 32A DP 10kA MCB - 6nos ,32A HRC Fuse link with neutral link -6nos and provision for for fixing single phase energy meter,-6 nos. Necessary holes are to be provided in the box for entry and exit of wire. The inter connection should be done using 4sq.mm copper wire fully p rewired and suitable frame work for fixing panel to the wall or floor with all fixing accessories complete as required. preferred make HENSEL or equivalent
1
-
-
OD7072/2023-2024:Supply and fixing 2A Single pole MCB C curve in existing enclosure or panel with all fixing accessories, connection, wiring etc complete as required.
1
-
-
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
OD7073/2023-2024:Supply and fixing 16mm dia LED type phase indication lamp (RED,YELLOW, GREEN) in existing panel or enclosure with suitable cutting making good the damaged with all fixing accessories wiring ,connection complete as required.
1
-
-
OD5090/2023-2024:Supply and fixing LED Bulk Head fitting 10W with Aluminium die-cast housing and polycarbonate optic materials including connection etc as required. The luminaire shall have IP66 protection, luminous flux 1100 lm, luminous efficiency 110 lumens/watt, cool daylight colour and 6500k colour temperature PHILIPS Endura LED Bulk Head model WT202W LED10S CW PSU S3 PC or equivalent
9
-
-
90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm
10
-
-
OD5102/2023-2024:Supplying and fixing 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 840 T8 API Philips or equivalent with all fixing accessories complete as required.
7
-
-
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
5
-
-
OD5137/2023-2024:Supply, installation testing and Commissioning of 4 x 65w Stand alone Solar Floodlight Minimast System with 24 hours backup with dimming option. Dimmable Floodlight Luminaires with 65W and 10500 Lumens System output with<br>a system efficacy greater than 160 Lumen per watts, IP66 & IK08 Protection, single piece Pressure die cast aluminum housing with ADC12 grade and individual lens mounted on led's by injection molding in PC Cover. The shall be<br>having anti corrosive coating with 1000 hours salt spray tested and L70 at 75000 Hrs - 4 nos, The Charge controller using in the system shall be MPPT type Hybrid Programmable and Dimmable with > 93% efficiency, IP67 Connectors- 4<br>nos, Solar Panel of 250Wp 36V Mono- Crystalline with excellent aging resistance and UV endurance to withstand harsh environment, environmentally sealed to IP67 -4 nos, The Batteries using in the system shall be Lithium Ferro Phosphate type with 60Ah 25.6V Maintenance free having minimum 2000 cycles life - 4 nos, And installing the system on 8 meters hot dip galvanized Octagonal Pole with top 70mm and bottom 175mm dia made of 3mm sheet thickness, base plate shall be not less than 275 x276x16mm, Mounting Brackets for holding Solar panels and Battery at top and Second ring bracket for fixing floodlights with all accessories. The pole shall be fixed by chemical anchoring process done in Concrete/Rock using Hilti 5.8 M20 X240 bolt -4 Nos and RE 500 chemical anchoring technic Hilti or equivalent .The threaded bolts should insert the rock/ concreate with a min of 10cm inside concrete by vertical drilling and fixing using the chemical as required. Cleaning of solar panels must be done at least once in every month during Defect Liability Period complete as required. The entire unit shall have the warranty of 3 year after installation.
2
-
-
90.3.18.4:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.50 mm dia with clamps made from 25 x 3 mm MS flat
5
-
-
90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
63
-
-
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
1
-
-
OD7092/2023-2024:Supply of following EXhaust fan in plastic frame working on 230v AC including giving connection etc as required 250mm light duty exhaust fan make crompton or equivalent
1
-
-
1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
1
-
-
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
10
-
-
OD7067/2023-2024:KSEB Documentation charge for getting electric connection and related statutory documentation work including preparation of drawing complete as required
6
-
-
14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
14
-
-
OD7094/2023-2024:Supply and installation of insulated 12 SWG GI wire for service binding wire including laying complte as required
45
-
-
OD7087/2023-2024:Supply and providing of 6mm thick &1 m wide electrical grade chequered type rubber mat to withstand 3.3 kv dielectric strength confirming to IS15652/2006 as required.
2
-
-
OD7096/2023-2024:Supply and Installation of ABC TYPE (STORED PRESSURE) fire extinguisher capacity 6 KG, confirming IS 15683 ,Fire Rating of 2A : 21B,Working Temperature ,-100C TO (+) 550C ,27 Bars ,Burst Pressure 50 Bars Minimum,Minimum Effective Discharge Time of 8sec,2 Metre with Convex Dome and Dish ,Brass, Squeeze Grip Type Control Valve ,Plastic nozzle with metallic insert fitted to hose complete as required
1
-
-
OD7260/2023-2024:Supplying and installation of Symmetrical LED based post top luminaire (SOFIA NW LED SYM 30W, IP66 or equivalent ) on the existing Tubular post or piller ,consisting of a high-pressure powder-coated die-cast aluminium housing, a canopy made of Plastamid and a UV-resistant highimpact polycarbonate protector. The luminaire emits a pleasant, glare-free light symmetric lighting. The complete luminaire is sealed to IP 66. The average power consumption shall be 50W The LED’s will be of neutral white. The protector shall be made of polycarbonate with IK 08 or above impact resistance. The luminaires shall have an inbuilt surge protection. complete with all fixing accessories connection etc.
2
-
-
Civil Work
-
-
-
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
250
-
-