Harbour Engineering Department Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Harbour Engineering Department - HED Tender

Works
Electrical Works
Eprocure
Opening Date3 Nov 2018
Closing Date26 Nov 2018
Tender Amount₹ 6,94,813 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Conveyance, installation, testing and commissioning of departmentally supplied flood light luminaire with lamp on the existing tubular post of height upto 15m from ground level. All bolt and nut shall be Stainless steel.

16

-

616.42

... More
Fabricating and supplying special clamping arrangement for fixing an asymmetrical beam Integral type flood light on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm ,10mm or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxy based industrial primer of approved quality and two coats of best quaity synthetic enamel paint of approved colour as per drawing.

16

-

713.41

... More
Supply and fixing 3/7 W LED lamp OSRAM / Philips or equivalent

2

-

138

... More
Providing and fixing 10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

30

-

70.56

... More
Supplying and fixing of surface/ recess mounting, vertical type, 415 volts,Dust and waterproof ,IP66 Hensel make or equivalent FP VN 0801 transparent door( 8 + 24 module) VTPN poly carbonate distribution board , with provision for MCCB as incomer, interconnection between incomer Isolator and bus bars of inclusive of125 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's painted, inclusive of , tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 8way

1

-

44499.1

... More
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required 40 A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL & SC

1

-

6785

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) Single pole

30

-

237.44

... More
ii)Double pole

32

-

635.47

... More
iii) Triple pole

5

-

960.75

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

4

-

204.5

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

15

-

369.2

... More
Supply and installation testing and commisioning of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 thermoplastic box or equivalent including supply and fixing Astronomical time switch with 2 channel - DIN Rail mounted of MakeTheben Model: SELEKTA 172 top 2 or equivalent with automatic calculation of sunrise and sunset times for the whole year & Offset for adjusting of sunrise and sunset times, 10 year power reserve, 2 modules (width 35 mm), 2 independent relay having capacity of 20A at power factor= 0.8, rail mounted astronomical time switch with factory-set time; text-oriented user guidance in the display, city database, automatic summer/winter time changeover, maximum offset +/-120 mins, weekly program plus, elapsed-time counter for light sources, ON/OFF permanent, option for night break selection for energy savings, relays should have external input supply option to override the switching status. Duo Fix screw less terminals, zero cross switching, two way switch 16A/250VAC; sealable transparent cover &PC programming suitable connectors , 415V 4pole 25A ,230V coil supply powercontactor - 2 Nos , Rotory cam operated single pole double position 6 A switch - 2 Nos, including giving connection using 4.0 sq.mm pvc insulated copper wire for power and 1.5 sq.mm pvc insulated copperwire for control wiring.

1

-

32983.46

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) for pile cap and plinth beam concrete.

1

-

8530.57

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.

1

-

266.2

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.

60

-

75.9

... More
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.

2

-

260.78

... More
Engaging labourers for checking the electrical installations, cables etc. and attending faults if any as per the direction of the departmental officers at site i) Wireman

10

-

680.56

... More
Line man

5

-

680.56

... More
Beldar

10

-

560.28

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.

8

-

1038.98

... More
Supplying and fixing 20mm size medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i) 20mm

20

-

78.23

... More
25mm

5

-

94.7

... More
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm

25

-

68.63

... More
3 x 2.5 sq. mm

5

-

102.94

... More
3 x 4 sq. mm

6

-

152.35

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

1

-

429.59

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

8

-

63.14

... More
Painting with epoxy primer of approved brand and manufacture of required colour to give an even shade :

15

-

94.46

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.

15

-

168.13

... More
Supply and fixing cubicle type dust and vermin proof 300x600x170 mm, (Mi 0400) Hensel make thermoplastic IP 65 junction box with lid including supplying and fixing 2 Nos Hensel make 10 sq.mm 5pole terminal set for phases and neutral in the existing masonry cubicle fixing the departmentally supplied double pole MCB including giving connection using 2.5 sq.mmpvc insulated copper wire ,drilling necessary holes for termination as well as entry and exit of cable,terminating the earthwire in the earthstrip etc complete.All the bolt nut & washer shall be brass.

4

-

10097.93

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.

100

-

34.31

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

50

-

24.71

... More
Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable

144

-

119.78

... More
Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.

16

-

227.58

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.

2

-

10356.89

... More
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5CX35 sq. Mm PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

4

-

387.05

... More
Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 16 sq. Mm PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

4

-

349.99

... More
Supplying and making end termination with brass compression gland and aluminium lugs for 4C x 10 sq.mm PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

4

-

278.62

... More
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.

5

-

263.52

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 module metal box in recess

1

-

253.91

... More
2 module metal box in recess

1

-

240.19

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door

1

-

1456.22

... More
Supplying and fixing 40A, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.

1

-

304.7

... More
Supplying and fixing 40A double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

1

-

2359.33

... More
Supplying modular family street light luminaire CITY or equivalent 40W LED,an IP66 LEdSafe® optical compartment,a separate IP66 control gear compartment and extruded aluminium painted housing, a toughened glass protector,permanently sealed with a robotically dispensed silicone sealant,closed at one end by an end cover and the other end by a frame and door assembly (to access control gear) both made of injection moulded polycarbonate,a removable control gear plate,safety plug and socket system,high pressure die cast aluminium painted mounting spigot suitable for horizontal mounting (Ø32-42mm) with tilt flexibility of ± 10 degrees, with lensoFlex2® technology,PMMA lenses with wide photometry for increased pole spacing,System efficacy= 90 lumen/watt, Driver efficiency = 85%, K 07 impact resistance , driver operating voltage 140 V to 277 V, lifetime residual flux @ Tq 35º @50,0000 hours =70%,Ta = 55º,surge protection of 10Kv ( in differential and common mode),Power factor ≥0.90,colour rendering index≥70 and neutral white light (4,100ºK- 5600ºK).

8

-

9142.5

... More
Supply of 4 core 10 sq mm PVC insulated and PVC sheathed armoured aluminum cable

35

-

164.7

... More
Supply of 4 core 16 sq mm PVC insulated and PVC sheathed armoured aluminum cable

45

-

182.88

... More
Supply of 3.5 core 35 sq mm PVC insulated and PVC sheathed armoured aluminum cable

20

-

274.86

... More
Supplying and laying of 63mm dia DWC HDPE pipe ISImarked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

40

-

108.43

... More
Supplying and fixing 63A, 3pole , 25 KA MCCB setted to 50A with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

1

-

6486.91

... More
Supply and installation of wall mounting cubicle type dust and vermin proof size 300x450x170 mm, Mi2300 thermoplastic meterbox with 25-40A,16 k A,TP MCCB with rotary handle for MCCB , with necessary interconnection with suitably rated copper conductor. Necessary hole for fixing rotary handle in the thermoplastic box is to be provided.

2

-

12025.32

... More
Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½C X 35 sq. mm

2

-

1942.09

... More
4CX 16 sq. mm

2

-

1708.76

... More
4C X 2.5 sq.mm

2

-

1000.21

... More
Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable

25

-

188.23

... More
Supplying and making end termination nickel plated single compression brass cable gland for 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.

2

-

233.33

... More
Supplying of 400W Tubular Philips/GE/Bajaj make sodium vapour lamp and fixing in the flood light fitting/ street light after removing the damaged lamp, cleanng the reflector and front glass cover and fixing the front cover with new gasket to make the luminaire weather proof and testing the same after installing the new lamp.

2

-

886.64

... More
Supplying of low loss electromagnetic ballast with silicon steel lamination suitable for 400W sodium vapour lamp super enamelled copper wire wound core and coil, embodded in polyester thermo setting compound and having taping for 220V/240V 50Hz AC supply at the terminal block of Philips/GE/Bajaj make and fixing it in the control gear box after removing the damaged ballast, testing the same after installing the new ballast.

2

-

2446.39

... More
Supplying of electromagnetic igniter suitable for 400W sodium vapour lamp , enclosed in polypropelene insuluating container of Phyljps/GE/Bajaj make and fixing it in the control gearr box after removing the damaged ignitor, testing the same after installing the new igniter.

2

-

531.64

... More
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required

12

-

158.11

... More
Supplying and fixing of 42MFD 240V capacitor suitable for 400W HPSV Lamp and fixing it in the control gear box after removing the damaged capacitor , testing the same after installing the new capacitor.

2

-

433.89

... More
Dismantling the sodium vapour light fitting mounted on top of the tubular post, conveying and keeping at a safe place within the harbour premises pointed out by the departmental officers for rectification of fault.

10

-

394.28

... More
Labour charges for checking the dismantled sodium vapour light fitting and its control gear and identifying the faulty components

10

-

326.22



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.