Harbour Engineering Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 6,500Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_HED_253929_1Bid Award Id
ViewTender No
86/HED/NC/2018-19Tender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
25mm
15
-
78.8
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
3 x 1.5 sq. mm
98
-
69.12
3 x 2.5 sq. mm
24
-
103.68
3 x 4 sq. mm
16
-
153.45
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
18.5
-
120.27
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
6
-
251.6
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
4
-
432.69
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
25
-
63.59
Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
-
-
-
1 or 2 Module (75mmX75mm)
6
-
241.92
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
6
-
398.13
Supplying and fixing 12 way double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1
-
1591.14
Supplying and fixing Single pole 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker of the following poles suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.
9
-
239.16
Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 865 T8 API Philips or equivalent
7
-
862.5
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
7
-
138.24
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
6
-
145.15
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
6
-
2012.5
Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
12
-
30.41
Supplying and fixing brass batten/ angle holder including connection etc. as required.
2
-
103.68
Supply and fixing 3/5 W LED ,BC, lamp OSRAM or equivalent
4
-
138
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
2
-
10431.59
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
1.25
-
964.92
Supply of SID or equivalent Street light luminaire 20W LED, an IP66 optical & control gear compartment, a die cast aluminium painted housing, Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy 105 Lumen/W at Ta 25⁰C. Lifetime residual flux @ Tq 35⁰C @ 50,000 hours = 70%, Ta = 50⁰C, in built surge protection of 4kV (in Differential and Common mode), Power Factor 0.95, Colour Rendering Index 70 and Cool white light (5700⁰K).
2
-
2955.5
Supplying and drawing 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
50
-
26.27
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
1
-
84.33
Supplying and drawing UTP four pair CAT 6 LAN cable in the existing surface/recess steel/ PVC conduit
65
-
47
Supply, fabrication, conveyance and fixing 40 mmdia B class GI pipe with clampsmade from 20x3 mm MS flat bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
6
-
371.33
Supply of Exhaust fan 305mm sweep single phase, light duty 1400 RPM, Almonard or Equivalent
2
-
1932
Installation of exhaust fan upto 450mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
2
-
309.66
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box/CMS including connections but excluding modular plate etc. as required.
-
-
-
6 pin 15/16 amp socket outlet
2
-
211.51
5/6 A switch
28
-
116.12
16A 1 way switch
2
-
157.59
RJ 11 Telephone jack
5
-
132.71
3 pin 5/6 amp socket outlet
28
-
111.97
CAT 6 RJ 45 computer data socket
8
-
333.65
RJ 45 frame
8
-
85.53
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
1
-
205.98
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
2
-
33.18
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
-
-
-
3 module
7
-
255.74
1 or 2 Module
1
-
241.92
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2
-
9.68
Supply and fixing 105 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess including switch plate
30
-
1719.4
Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 Hensel make thermoplastic meterbox with provision for fixing KSEB meter, cut out & Neutral link with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link.
-
-
-
Supply and providing 1No 32A TP MCCB setted to 25A with rotary handle and 1 No. of 32A HRC fuse units with 20A HRC fuse link and 1No 32A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire The inter connection should be done using 6.00 sq.mm copper wire.
1
-
15860.59
Identifying cables, supply and crimping RJ 45 cable jack on the cable end and giving connection
8
-
16.02
Supplying and fixing 8 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
1
-
1466.73
Supplying surface mounted /suspended LED luminaire having =3000 lumen. Preffered Phillips make SM270C LED 30S 6500PSU WH LED luminaire or equivalent
2
-
4922
Supplying and fixing PHILIPS LED surface mounted light fitting of the model Round surface having =1000 lumen.Preffered make: phillips DN092B LED 10S-6500 PSU WH
1
-
2292.64
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
2
-
341.45
Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length wiring with 2 X 1.5 sq. mm FR PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
4
-
44.24
Supplying and fixing following Modular base & cover plate on existing CMS as required.
-
-
-
1 or 2 Module
7
-
114.74
3 Module
9
-
125.8
6 Module
7
-
174.18
Supply and providing RCC covering slab covering slab of size 55x55x8cm constructed with the following for the inspection chamber of earth pit as required
-
-
-
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
0.05
-
7585.23
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
1.4
-
262.66
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
2
-
159.14
Supplying and fixing 40A, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2
-
306.89
Supplying and fixing 40A double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
2376.35
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for 3-14W LED lamps including connection etc as required.
2
-
597.5
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.
6
-
155.04
Supplying and fixing 32 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
2
-
273.72
Supply, installation testing and commissioning wall mounting type dust and vermin proof enclosure 6 U rack system with standard accessories patch panel,cable manager , power strip, cooling fan, cable tray (Model 6U)
1
-
13122.65
Supply, installing, commissioning of manageable switch having Minimum 24 X 10/100/1000 Base-T Ethernet ports, 2 10/100/1000 Base - T Ethernet ports and 2 10000 Base-X SFP Ports (COMBO)• Switching Capacity should be minimum 8.8 Gbps and Minimum 6.55 MPPs Throughput• Switch should support minimum 1000 VLAN's and VLAN ID's,Port-based VLAN and MAC-based VLAN,802.1Q VLAN tagging,Software upgrades,SNM PV2 and SNM Pv3, and MAC limiting. • Switch should be Manageable through CLI, web Interface and SSH.
1
-
18630
Supply of Cat 6,2 metre patch cord
7
-
205.28
Supply of Cat 6,2 metre patch cord
7
-
181.13
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements