Harbour Engineering Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 17,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_HED_246776_1Bid Award Id
ViewTender No
68/HED/NC/2018-19Tender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Conveyance, installation, testing and commissioning of departmentally supplied flood light luminaire with lamp on the existing tubular post of height upto 15m from ground level. All bolt and nut shall be Stainless steel.
5
-
620.17
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
5
-
34.56
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
140
-
24.88
Supply of 4 core 16 sq mm PVC insulated and PVC sheathed armoured aluminum cable
55
-
182.85
Supplying and laying 63mm dia (OD 63mm and ID 51mm nominal)DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
50
-
186.62
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4x16 sq.mm (25mm)
2
-
352.51
Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
10
-
228.39
Providing and fixing 10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
55
-
71.07
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
6
-
120.27
Providing and laying earth connection FRLS earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from FRLS on earth electrode including connection with copper thimble excavation and re-filling as required.
8
-
251.6
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
1.2
-
964.92
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
2
-
10431.59
Supplying and fixing 20mm size medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm
6
-
78.8
Supplying and fixing 20mm size medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm
383
-
95.39
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
607
-
69.12
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
10
-
103.68
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
4
-
239.16
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
5
-
640.05
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2
-
205.98
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
10
-
371.87
Providing and laying in position reinforced cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required (excluding reinforcement).
1.03
-
7585.23
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.
1
-
268.12
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Mild steel and Medium Tensile steel bars
41.2
-
76.45
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
2
-
262.66
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
4
-
138.24
Engaging labourers for checking the electrical installations and attending faults if any as per the direction of the departmental officers at siteWireman
6
-
684.98
Engaging labourers for checking the electrical installations and attending faults if any as per the direction of the departmental officers at siteBeldar
4
-
563.92
Supply of 65 mm dia Heavy (Class C) ISI GI pipe for fixing external lights
10
-
632.5
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
11
-
159.14
Supply and fixing of special clamp painted with two coats of enamel paint over a coat of red oxide primer for fixing LED tube fitting in the roof structure using 32x6mm MS flat using 4 Nos of 32mm brass screws
4
-
366.43
Fabricating, supplying, conveying, lifting and erecting tubular post of overall height 11.70 m using 150mm and 125mm of Heavy duty G.I. Pipe each of 6m sections having ISI mark and of approved quality(TATA , ZENITH , APOLLO) as per the drawing erected on a RCC footing 1.5m length,1.3m width and 2.5m height with a muffing of .6m x .6m x 1 m , using 1:2:4 CC with nominal reinforcement and 8 numbers of 20mm dia 3.5 m long MS foundation bolts having 150mm long standard thread on both ends and 3Nos 20mm and 2Nos 20mm nuts at the top and bottom for each bolt . The post is to be provided with a 20mm thick MS flange of OD 300mm with 8 nos of 20mm bolt holes and a base plate of 450mm square 10mm thick with 8 Nos 20mm dia bolt holes embedded in the concrete 2 m below ground level. The post should have a 1500mm dia ring made out of 50mm heavy GI pipe with cross supports using 40mm heavy GI pipe at the top for mounting the luminaries and its control gears. A 10mm thick MS flange having OD 300mm at 1200mm below the first ring mounted to the post . The top of the pipe should be sealed with 125mm dia Dummy flange and pipe flange. 12mm dia wire rope is to be provided for the entire length of the post as mechanical support for the cables to the luminaries. Inverted Y arrangement using 50mm heavy GI pipe and flanges at the top and 75mm 4kgf/cm2 PVC pipe with bend to be provided in the concrete muffing for taking out cables. 8 x 75mm stainless steel Bolt & Nut shall be used for fixing all the flange covers.The post is to be painted with two coats of UV resistant polyeruthene paint of approved quality and colour over two coats of best quality industrial epoxy primer and epoxy paint.All steel items shall be hot dip galvanise
1
-
132505.5
Supplying Philips BVP 410 LED 172 CW HE NB FGS3XT Flood lighting luminaire IP 66,17200 lumens,colour 6000K with high power LED or equivalent
4
-
38318
Fabricating and supplying special clamping arrangement for fixing LED flood light on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm ,10mm or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxy based industrial primer of approved quality and two coats of best quaity synthetic enamel paint of approved colour as per drawing.
5
-
675.04
Supply and fixing cubicle type dust and vermin proof 300x600x170 mm, (Mi 0401) Hensel make thermoplastic IP 65 junction box with lid including supplying and fixing 2 Nos Hensel make 10 sq.mm 5pole terminal set for phases and neutral in the existing masonry cubicle fixing the departmentally supplied double pole MCB including giving connection using 2.5 sq.mmpvc insulated copper wire ,drilling necessary holes for termination as well as entry and exit of cable,terminating the earthwire in the earthstrip etc complete.All the bolt nut & washer shall be brass.
2
-
10029.97
Dismantling the existing light mast having overall height upto 12 m by cutting at the bottom,cleaning the rusted surface and erecting the tubular post on new foundation of RCC footing, using 1:2:4 CC with nominal reinforcement and 6 Nos. of PCC well steining having 0.9m dia and 0.30m height with a muffing of 0.6mx0.6mx0.8m and 8 numbers of 20mm dia 2.50m long MS foundation bolts having 150mm long standard thread on both ends and 3Nos 20mm and 2Nos 20mm nuts at the top and bottom for each bolt . The post is to be provided with a 20mm thick MS flange of OD 300mm with 8 nos of 20mm bolt holes and a base plate of 450mm square 10mm thick with 8 Nos 20mm dia bolt holes embedded in the concrete 1.8m below ground level. 12mm dia wire rope is to be provided for the entire length of the post as mechanical support for the cables to the luminaries. Inverted Y arrangement using 50mm heavy GI pipe and flanges at the top and 75mm 4kgf/cm2 PVC pipe with bend to be provided in the concrete muffing for taking out cables. 8 x 75mm stainless steel Bolt & Nut shall be used for fixing all the flange covers.The post is to be painted with two coats of UV resistant polyeruthene paint of approved quality and colour over two coats of best quality industrial epoxy primer and epoxy paint.All steel items shall be hot dip galvanise
1
-
67733.19
Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured Copper cable
90
-
119.6
Dismounting the existing flood light from the tubular post of height upto 15m from ground level without any damage and keep at a place as per the instruction of the depatmental officer at site.
2
-
605.17
Supply and fixing Cable Junction Boxes IP 66 for outdoor applications ( with knock outs for cable entry - Black Colour)) suitable for cable sizes 2.5 sq.mm ,88 X 88X 53 mm Hensel model No KF 5025 or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
4
-
592.75
Supplying and fixing 3 module GI box in recess alongwith modular base & cover plate for modular switches in recess etc as required.
5
-
241.92
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1
-
207.36
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 16A 1 way switch
11
-
153.45
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
15
-
59.44
Painting with 2 Coats of Industrial based Epoxy primer of approved brand and manufacture on steel galvanised iron/steel works (2 Coats)
3.1
-
109.13
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
3.1
-
99.38
Supply, fabrication, conveyance and fixing of 40 mm dia Medium class GI pipe with clamps made from 20 x 3 mm MS flat bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
12
-
384.66
Supply and fixing Anchor footing for 65 mm GI lamp post using 20cm x20 cm , 15 mm thick MS plate and 4 nos 20mm dia 75 mm long anchor bolt and erecting 1:2:4 Cement concrete of size 30 cmx30cmx45cm with nominal reinforcement .
5
-
826.79
Evaluation Notes How It Works ?
Potential Partner