Harbour Engineering Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HED_691614_1Tender No
HED/CEHED/TR/726/2024_6_1_1/1Tender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
23
-
-
1.15.2:Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group B
6
-
-
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
726
-
-
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
75
-
-
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
276
-
-
1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
18
-
-
1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
20
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
477
-
-
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
81
-
-
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
12
-
-
1.22.8:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 75 mm deep
1
-
-
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
64
-
-
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
42
-
-
1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
2
-
-
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1
-
-
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
3
-
-
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
10
-
-
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
2
-
-
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
3
-
-
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2
-
-
1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
5
-
-
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
7
-
-
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
4
-
-
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
3
-
-
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
2
-
-
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
62
-
-
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
6
-
-
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
53
-
-
1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
2
-
-
1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
1
-
-
1.52:Painting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc. as required.
2
-
-
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
120
-
-
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1
-
-
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
1
-
-
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
36
-
-
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
16
-
-
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
4
-
-
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
12
-
-
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
23
-
-
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
17
-
-
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
4
-
-
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
-
-
2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
1
-
-
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2
-
-
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
10
-
-
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
100
-
-
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
4.5
-
-
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
100
-
-
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
8
-
-
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
8
-
-
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
2
-
-
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
100.09
-
-
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
7.53
-
-
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
11.8
-
-
14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia
3
-
-
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
30.4
-
-
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
10
-
-
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
2
-
-
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
3
-
-
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
1
-
-
90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
239.5
-
-
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
7
-
-
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
7
-
-
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
4
-
-
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
285
-
-
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
10
-
-
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
20
-
-
90.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
285
-
-
90.12.24.1:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.2.5 sq mm
100
-
-
90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm
48
-
-
90.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
1
-
-
90.15.1.1:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm top diameter. 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for windspeed as per IS 875 Part III fixed head frame including round arm luminary carriage suitable to install 4/6 nos luminaries in symmetrical arrangement including connector foundation bolt 4 nos existing RCC foundation and junction box etc, complete 8 Meters
2
-
-
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
5
-
-
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
10
-
-
90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
18
-
-
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
325
-
-
OD4351/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof 300x300x170 mm, Hensel make polycarbonate Enclosure - IP66 size 2 box K0200 or equivalent in wall with all fixing accessories and cutting holes for bus bar arrangement and sealed with suitable binding agent complete as required.
2
-
-
OD4352/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof 300x600x170 mm, Hensel make polycarbonate Enclosure - IP66 size 4 box K0400 or equivalent in wall with all fixing accessories and cutting holes for bus bar arrangement and sealed with suitable binding agent complete as required.
4
-
-
OD4365/2024-2025:Providing 12 SWG insulated GI wire for service wire binding along with service line complete with all accessories complete as required.
45
-
-
OD4366/2024-2025:Supply and installation of wall mounting cubicle type Hensel make mi9410 or equivalent thermoplastic polycarbonate energy meter enclosure with hinged lid 315 x 600 x 214 mm , size 4 , with supply and fixing of 40 A ,16 kA,4P,MCCB With BUC rotary drive kit,inter connection using 10 sqmm PVC insulated copper wire . Necessary holes are to be provided in the box for entry and exit of wire and sealed the joint with suitable sealing agent,etc. all fixing accessories complete as required.
2
-
-
OD4349/2024-2025:Supply and installation of wall mounting cubicle type Hensel make Mi 9300 or equivalent thermoplastic polycarbonate energy meter enclosure with hinged lid 315x 450 x 170 mm size-3 box IP65 with base plate for fixing KSEB meter, cut out & Neutral link and 20A, 10kA DP MCB, C-curve, with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing 1No 20A,10kA ,DP MCB C curve , 1 No 32A HRC fuse units with 20A HRC fuse link and 1No 32A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire. The inter connection should be done using 4sq.mm copper wire.
17
-
-
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
900
-
-
90.14.7:Supply and providing copper earth bus in the panel board
450
-
-
OD4367/2024-2025:KSEB Documentation charge for getting new connection connected work including preparation of drawing ,file work submitting application etc complete as req
2
-
-
OD4244/2024-2025:Supplying 16mm dia LED type Phase indication lamp Blue
2
-
-
OD4243/2024-2025:Supplying 16mm dia LED type Phase indication lamp and motor ON indication (Red , Yellow & Green
4
-
-
OD4242/2024-2025:Supplying 2A single pole MCB C curve
6
-
-
OD4370/2024-2025:Supply and fixing 80 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess including all accessories like internal/external angle end cap etc complete with all fixing accessories.
20
-
-
OD4371/2024-2025:Supply and fixing 105 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess including all accessories like end cap internal/external angle etc complete with all fixing accessories.
75
-
-
OD4372/2024-2025:Supplying and fixing following Modular base & cover plate on existing existing CMS 105X50mm. as required.1 or 2 Module base and cover plate
12
-
-
OD4373/2024-2025:Supplying and fixing following Modular base & cover plate on existing CMS 105X50mm etc. as required.3 Module base and cover plate.
12
-
-
OD4374/2024-2025:Supplying and fixing following Modular base & cover plate on existing CMS 105X50mm etc. as required.6 Module base and cover plate.
12
-
-
OD4375/2024-2025:Supply of Cat 6,2 metre patch cord
6
-
-
OD4376/2024-2025:Supply of Cat 6,1 meter patch cord
6
-
-
OD4377/2024-2025:Wiring the patch panel and Configuring of Manageable network switch complete
1
-
-
OD4378/2024-2025:Supply Push Button Telephone Preferred make; Beetel C-11
1
-
-
OD4379/2024-2025:Supply, installing HENSEL telephone junction box K9250 size 200x160x98 mm having 20 pair KRONE type telephone wire connector suitable for 0.50 mm dia copper wire of approved quality mounted on a suitable G.I. frame. All the telephone wires are to be identified and terminated on the block as per the colour code using the special crimping tool as per the instruction of the departmental officer.
1
-
-
OD4137/2024-2025:Supply, installation, testing and commissioning of 230V AC, 50HZ ,3KVA IGBT based PWM technology microprocessor controlled double conversion true Online UPS(96 V CD or above) capable for automatic changeover from mains to UPS on mains failure and vice versa with built in isolation transformer of make APC/NUMERIC/GE or equivalent suitable to Work with 8Nos 12V,100 Ah, rated tubular type battery bank C10 for UPS application suitable for 3 hours backup on full load with suitable wooden rack for mounting the batteries. Single phase Input Voltage Range 160-300 V AC, Output Frequency-50 ±. 01Hz,Output voltage Range :230VAC ± 1% ,Output power rating: 2400W/3000VA, Interface port:RS232 and com port, Front panel Display: LCD, input power factor:0.99, input Current THD <10% at full load, Output Voltage THD < 3%(Linear Load),THD <5%(NonLinear load), Overall efficiency >=90%, Overload capacity :1min @ 111%-130% of rated load,10 minut @ 105%-110% of rated load, Load power factor: 0.8 lag or better, Load crest factor : 3:1, Noise level: <50 dBA at 1 meter, Continuous Operating Temperature: 0-40 °C, Constant current & constant Voltage with optional Temperature compensated battery charging. Standards: EMC- EN 62040-2, Safety- EN 62040-1, Performance- IEC 62040-3, Certifications: BIS, OSHAS, CE, PeP, RoHS, ISO 9001 & ISO 14001 ,Warranty :3 years on site warranty from the date of installation for UPS & 4 year for battery after installation
1
-
-
OD4230/2024-2025:Supply, installing, commissioning of manageable switch having Minimum 24 X 10/100/1000 Base-T Ethernet ports, 2 10/100/1000 Base - T Ethernet ports and 2 10000 Base-X SFP Ports (COMBO)• Switching Capacity should be minimum 8.8 Gbps and Minimum 6.55 MPPs Throughput• Switch should support minimum 1000 VLAN's and VLAN ID's,Port-based VLAN and MACbased VLAN,802.1Q VLAN tagging,Software upgrades,SNM PV2 and SNM Pv3, and MAC limiting. • Switch should be Manageable through CLI, web Interface and SSH complete as required. Preferred make 24-Ports 10/100/1000Mbps & 4 Ports 10G SFP+ Smart Managed Switch, DGS-1250-28X D link or equivalent.
1
-
-
OD4340/2024-2025:Supply and fixing Floor Mount 9U Rack including , AC Distribution box(x1), fan (x1) Closed type cable manager and hardware mounting kit Recommended: Legrand/Netrack.
1
-
-
OD4341/2024-2025:Identifying the CAT6/Telephone cable and the termination the end with male connectors/ existing sockets using special crimping tools complete as required.
28
-
-
OD4815/2024-2025:Supply and installing 7+/-2W LED bulkhead fitting (IP 65), housing made of die cast aluminium with 6500K colour temperature with a lumen output minimum 100lumen/Watt, CRI>80,beam angle 120 degrees, suitable for outdoor applications, including all connections etc. as required. Make -Philips -Vista glow or equivalent
6
-
-
OD4236/2024-2025:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.CAT 6 RJ 45 computer data socket
12
-
-
OD4237/2024-2025:Supplying and fixing Cat 6 RJ 45 Frame on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
12
-
-
OD4304/2024-2025:Supply and fixing Cable Junction Boxes IP 65 for outdoor applications (Thermoplastic Polycarbonate ) suitable for cable sizes 2.5 sq.mm ,80 X 80X 52 mm Cape model Abox i025 or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required
26
-
-
OD4440/2024-2025:Supply Installation and Testing of Unmanaged Gigabit Ethernet Network Switch of 8 port compliant with IEEE802.3az Energy Efficient Ethernet mode. and may use as Hub, Internet Splitter, Desktop switch. The switch should be in ready to used type Plug and Play. Preferred make NETGEAR GS308 8-Port with all fixing accessories power supply adapter complete as required
1
-
-
OD4441/2024-2025:Fabricating supplying and fixing special clamping arrangement for fixing LED bay light and cable junction box to the beam using 500 mm long 50x6mm MS flat, 12mm dia MS round bar with U shape open hook fixed vertically to hang the luminaire welded to the 50x6 mm MS flat and 2 pieces of 1.1m 32 x 6mm MS flat welded to the rod for fixing the cable junction box . The entire arrangement is to be fixed to the beam using 6 x 25 mm SS bolt and nut 2 Nos on each. All the items are to be painted with two coats of epoxy based industrial primer of approved quality and two coats of best quality epoxy paint of approved colour as per drawing.
5
-
-
OD4305/2024-2025:Supply and fixing IP 65 HENSEL 1 row 9 module( Model No KV 7109) KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws.
4
-
-
OD4550/2024-2025:Supply and fixing IP 65 HENSEL 1 row 6 module( Model No KV 7106)146 x 238 x 111 KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws.
16
-
-
OD4816/2024-2025:Supplying and fixing of 6-Inch Exhaust Fan with Aerodynamic blades for faster speed, light weight, rust proof body and blades150mm Sweep and Plastic blade material. Crompton/equivalent
1
-
-
OD4277/2024-2025:Supply and Installation of LED Industrial Bay luminaire with a system wattage of 80W, electrical Class I, made of pressure die cast Aluminium body sealed with a polycarbonate protector for an optimal luminous flux with IP65 optical compartment. The luminaire shall have a system efficacy of 150lm/w, CCT of 5700K and colour rendering index (CRI) ≥70. The Driver (efficiency ≥90%) has internal surge protection of 4/6 kV. Power Factor ≥0.9, a residual flux of ≥70% (L70) @ 50,000 hours,Light Source Colour755 cool white. The Luminaire shall be able to be installed by a hook complete as required. Preferred make KOMPACT-III 80W CW LED or equivalent.
8
-
-
OD4259/2024-2025:supply of weather proof LED luminaire IP65 rated having power consumption of 34 W and light output not less than 2100 lm with system efficiency >120 lumens/watt. Luminaire housing made from superior quality of polycarbonate extrusion IP65 and and IK 08 protection. The luminaire should be having minimum 30000 Burning hours with CRI >=80 and co related colour temperature(CCT)of 6500K. Preferred make Philips WT 150C LED 40S-6500 PSU L120 or equivalent
53
-
-
OD4307/2024-2025:Supply and fixing of special clamp painted with two coats of enamel paint over a coat of red oxide primer for fixing LED tube fitting in the roof structure using 32x6mm MS flat using 4 Nos of 32mm brass screws etc complete as required
21
-
-
OD4308/2024-2025:Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
10
-
-
OD4309/2024-2025:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured Copper control cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 2.5 sq mm with factory made clamp
75
-
-
OD4310/2024-2025: Supplying and fixing Osram CLASS A B22 7/9-Watt LED Lamp .
6
-
-
OD4311/2024-2025:Supplying and fixing surface /recess mounting Vertical TPN distribution board with Double door , dust and water proof IP 66 Hensel make FP VN 0412 opaque or equivalent , 8+12 4 way DB of poly carbonate inclusive of tinned copper 250A busbar, common neutral link, earth bar,din bar for mounting MCB's with provision for MCCB as incomer.
1
-
-
OD4312/2024-2025:Supplying and fixing HENSEL make KV -thermoplastic circuit breker boxes IP65 with metrick knock out for cable entry, 1 row 12 module size 295x333x129 KV9112 M with PE+N terminals
1
-
-
OD4313/2024-2025:Conveyance, installation, testing and commissioning of departmentally supplied flood light luminaire with lamp and control gear on the existing tubular post of height up to 15m from ground level
9
-
-
OD4350/2024-2025:Supply and providing 15mm PVC gland at the junction including drilling necessary holes as required.
16
-
-
OD4314/2024-2025:Supplying 200W,23500 Lumens floodlight luminaire suitable for high mast lighting with single piece die cast aluminum housing with inbuilt potted driver & 10KV inside surge protection device for luminaire, IP66 optical tightness, IP67 driver tightness, IK 10 Impact resistance having operating voltage range 120-277 V, luminaire efficacy >= 110lumen/watt, color temperature 5700 K color rendering index >75, electrical class- I, Lumen maintenance L70@60,000 hrs etc complete . Preferred make: PHILIPS or equivalent.
4
-
-
OD4324/2024-2025:Fabricating and supplying special clamping arrangement for fixing an asymmetrical beam integral LED flood light on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm,10mm, or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxybased industrial primer of approved quality and two coats of epoxy paint of approved color as per drawing.
4
-
-
OD4251/2024-2025:Supply and installation of extra length of foundation bolt of size 20mm diameter , 200mm pitch circle diameter manufactured from special steel suitable for 8M octogonal poles with suitable stiffener piece etc. complete as required.
10
-
-
OD4252/2024-2025:Supply and installing RCC precast well steining of size 750mm dia and 300m height complete with all expense at site.
12
-
-
OD4323/2024-2025:Supply and fixing Cable Junction Boxes IP 66 for outdoor applications( with metric knock outs for cable entry - Black Color)) suitable for cable sizes up to 16/25 sq.mm, 200 X 160 X 98 mm Hensel model No KF 5255 or equivalent and accessories for Cable Junction Boxes such as Terminal Set 2.5 sq.mm / 4 sq.mm including giving necessary connections, making good the damages etc. as required.
2
-
-
OD4321/2024-2025:Engaging labour for electrical maintenance works as per the direction of site in charge-Khallasi
6
-
-
OD4322/2024-2025:Engaging labour for dismantling the light fittings, checking the electrical installations, rectifying defects, etc if any as per the direction of the departmental officers at the site - Wireman
6
-
-
OD4335/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
80
-
-
OD4811/2024-2025:Supply and installation of 8 meter Solar Highmast with bottom min 310mm and top 150mm.Base Plate shall be min 25mm thick and minimum 6nos foundation bolts of M24 850mm long. The pole shall be provided with all accessories suitable for mounting above mentioned solar floodlight in double lantern carriage. The mast shall be designed to for raising and lowering sing suitable load winch by manual operation. The mast shall be structurally designed to withstand 39m/s wind speed . Preferred make Philips / Utkarsh /Keselec or equivalent. The entire unit shall have a warranty of 5years.
1
-
-
OD4812/2024-2025:Supply and installation of extra length of foundation bolt of size M24 Galvanised MS bolt in RCC foundation with suitable stiffener piece etc. complete as required.
6
-
-
OD4814/2024-2025:Supply, installation, Programming ,Testing and commissioning of 80W Non integral Solar Floodlight System with 24 hours back up with dimming option. Floodlight Luminaire shall have min 13,000 Lumens System output greater than 160 Lumens Per watt system efficiency, IP66 & K08 Protection, luminaire made of single piece Pressure Diecast aluminum Housing and individual lens for each LED embedded PC cover. minimum75,000 burning hours as per L70 and 500 hours Salt spray tested finish of Philips BVP483 series or quivalent. The Solar Panel shall be min 200Wp Mono-Crystalline of 39V with excellent aging resistance and UV endurance to withstand harsh environment, environmentally sealed to IP67 .The Batteries using in the system shall be Lithium Pherro Phospate type with 25.6V 72Ah with 1843Wh Maintenance free having minimum 2000 cycles life .The Charge controller using in the system shall be MPPT type Programmable and 4 step Dimmable via app with >93% efficiency and IP67 Connectors. Built in protection of Battery Reverse Polarity, Panel Reverse Polarity, Panel Reverse Current, Surge Protection at PV input, Battery over Voltage, Load short circuit and fuse protection in series for battery.Cleaning of solar panels must be done at least once in every month during DLP period. The entire unit shall have an warranty of 5years. Preffered Make : PHILIPS/OSRAM/KESSLEC or equivalent
4
-
-
Civil Work
-
-
-
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
7.97
-
-
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
200
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements