Harbour Engineering Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,760Tender Fee
Refer Documents
Summary
Modernisation Of Existing Fishing Harbour At Koyilandi In Kozhikode District Of Kerala Under The Pmmsy_construction Of Administrative Building_ Electrification
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HED_681773_1Bid Award Id
ViewTender No
HED/CEHED/TR/21/2024_6_2_1/RC 1/2Tender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C
2
-
-
1.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
4
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
405
-
-
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
65
-
-
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
30
-
-
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
550
-
-
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
86
-
-
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
118
-
-
1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
10
-
-
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
8
-
-
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
3
-
-
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
93
-
-
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
21
-
-
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
21
-
-
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
22
-
-
1.22.3:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep
1
-
-
90.5.1.3:Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell
1
-
-
OD2336/2024-2025:Supplying and Installation of 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 840 T8 API Philips or equivalent with all fixing accessories directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
21
-
-
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
6
-
-
OD2337/2024-2025:Supply and fixing of LED Bulk Head fitting 10W with Aluminium die-cast housing and polycarbonate optic materials including all fixing accessories ,connection etc as required. The luminaire shall have IP66 protection, luminous flux 1100 lm, luminous efficiency 110 lumens/watt, cool daylight colour and 6500k colour temperature PHILIPS Endura LED Bulk Head model WT202W LED10S CW PSU S3 PC or equivalent
8
-
-
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
7
-
-
OD2338/2024-2025:Supply and fixing 7/9 W LED ,BC, lamp OSRAM or equivalent
7
-
-
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
21
-
-
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
3
-
-
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
4
-
-
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
35
-
-
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
35
-
-
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2
-
-
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
2
-
-
90.11.1.12:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
1
-
-
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
1
-
-
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2
-
-
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
16
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
40
-
-
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
3
-
-
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1
-
-
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1
-
-
OD2339/2024-2025:Supply and Installation, of Lighting luminaire(312 mm X 312 mm) SM200C LED16S 6500 PSU OD WH PHILIPS or equivalent having metalic CRCA powder coated housing,colour temperature 6500 K,colour rendering index 80,,electronic in built driver, pf greater than 0.9,THD less than 10%,IEC compliant for safety, performance and EMI. The luminaire shall have complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
2
-
-
OD2340/2024-2025:Supply Conveyance installation testing and commissioning of pre-wired 600 x 600 mm square type fluorescent fitting complete with all accessories and fluorescent lamps etc. suspended from ceiling using 4 nos steel chain (16 SWG or nearest) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (for fitting in false ceiling) Preferably make LED Full Glow 2X2 Panel 24 W (Cool Day Light, White). Philips Lighting RC370B 24-Watt LED or equivalent.
1
-
-
OD2341/2024-2025:Supply and installation of Wall washer light IP65,10W; Warm White; 950 lumen; In-built LED;, Dust-proof and water resistant;, Powder-coated premium aluminum fixture;, Perfect for highlighting outdoor walls and façade. Philips or equivalent.
2
-
-
OD2342/2024-2025:Supply and fixing of LED Bollard Fixture with E27 16W LED, light of 1Mtr length mounted on surface with all standard fixing accessories complete, The fixture should have extruded square aluminum alloy tube with powder coated graphite grey body , non corrosive SS fasters type fixture and Translucent polycarbonate diffusers. light have CRI.80,Warm light with integrated driver , pf>.9,THD <10% ,surge protection of 2.5 KV ,Efficiency of >80%, working voltage of 230 V,50Hz ac supply , IP54 rated IK08, preferred make K lite CUBA Bollard 6976 or equivalent.
2
-
-
OD2343/2024-2025:Supplying and fixing LED mirror lamp,5w 1feet tube warm white make Philips Astra line or equivalent with all fixing accessories complete as required
3
-
-
OD2344/2024-2025:Supplying surface/suspended mounted smartbrite luminaire SM 270C LED 30S 6500 PSU WH Philips or equivalent
19
-
-
90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
1
-
-
OD2345/2024-2025:supply and installation of 250 mm sweep 40 W exhaust fan with plastic body with a Speed 1250 RPM,Air delivery 720 CMH Crompton or equivalent in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
6
-
-
1.42:Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
19
-
-
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
2
-
-
1.43:Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
10
-
-
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
5
-
-
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
10
-
-
OD2346/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x315x214 mm, Mi9410 hinged lid thermoplastic meter box or equivalent with provision for fixing KSEB meter.Supply and providing 3 Nos of 32A HRC porcelain fuse units with 32A HRC fuse link and 1No 32A 2way porcelain neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire The inter connection should be done using 10.0 sq.mm copper wire. with all fixing arrangements etc complete.
1
-
-
OD2347/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi0410 thermoplastic box or equivalent including supply and fixing 40A, 16kA,4pole MCCB with BUC rotory drive kit , 3numbers of 2A SPMCB with RYB indication lamp and wiring the circuit with 2.5 sqmm copper wire complete.
1
-
-
90.12.24.1:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.2.5 sq mm
10
-
-
90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm
20
-
-
90.12.24.3:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm
12
-
-
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
26
-
-
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
10
-
-
90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm
10
-
-
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
40
-
-
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
3.3
-
-
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
4
-
-
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
15
-
-
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
5
-
-
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
5
-
-
OD2348/2024-2025:Supply of EPABX SYSTEM Equipped for 12 Extensions & 04 Trunk Line,Expandable Upto 16 Extensions & 6 Trunk Lines,Caller – ID Internal / External / Transferable,Caller – ID On Simultaneous Ringing,Dialed Number Shown as Caller – ID, Call Progress Visual Indicatio,Printout of Answered /Unanswered /Dialed Calls,Welcome Message,Hundred Memory Locations,Computer Connectivity for Call Management,Auto Redia,lRemote Maintenance, Auto Fax – Telephone Switch*Built – in Printer Interface With Buffer Interface, Various Options For SMDR Printing, Call Forwarding Call Waiting on P & T Lines, Various Extension Hunt Groups, Operator Less Operation, Intercom, Direct Outward Dialing, Call Forward On No Answer, Call Forward On Busy, Call Redirection to External Numbers, Barge in With or Without Tone, Distinctive Ring For External / Internal, Trunk Status Indication, Day / Night Service Operation, Automatic Padlock, Simultaneous Cyclic Ring for Incoming Calls.
1
-
-
OD2349/2024-2025:Supply, installing HENSEL telephone junction box K9250 size 200x160x98 mm having 20 pair KRONE type telephone wire connector suitable for 0.50 mm dia copper wire of approved quality mounted on a suitable G.I. frame. All the telephone wires are to be identified and terminated on the block as per the colour code using the special crimping tool as per the instruction of the departmental officer.
1
-
-
OD2350/2024-2025:Supply, Installation, Testing, and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required: a) Solar Photovoltaic Module of capacity 330 Wp or above, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730- Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories, etc. as required. e) Lightning and surge voltage protection including earthing f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, a main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. g) Statutory fees such as KSEB Fees (Application Fee, Registration fee & Liasioning Fee),Electrical Inspectorate Liasioning Fee, Net meter - (Including Testing/Calibration Liasioning Fee) etc are to be paid by the contractor as part of this work.
8
-
-
OD2351/2024-2025:Supply, installation, testing and commissioning of 230V AC, 50HZ ,3KVA IGBT based PWM technology microprocessor controlled double conversion true Online UPS(96 V CD or above) capable for automatic changeover from mains to UPS on mains failure and vice versa with built in isolation transformer of make APC/NUMERIC/GE or equivalent suitable to work with 8Nos 12V,100 Ah,rated tubular type battery bank C10 for UPS application suitable for 3 hours backup on full load with suitable metallic battery mounting rack .Single phase Input Voltage Range 160-300 V AC, Output Frequency-50 ±. 01Hz,Output voltage Range :230VAC ± 1% ,Output power rating:2400W/3000VA,Interface port:RS232 and com port,Front panel Display: LCD ,input power factor:0.99, input Current THD <10% at full load,Output Voltage THD < 3%(Linear Load),THD <5%(Non-Linear load),Overall efficiency >=90%,Overload capacity :1min @ 111%-130% of rated load,10 minut @ 105%-110% of rated load,Load power factor: 0.8 lag or better,Load crest factor : 3:1, Noise level: <50 dBA at 1 meter, Continuous Operating Temperature: 0-40 °C,Constant current & constant Voltage with optional Temperature compensated battery charging. Standards: EMC- EN 62040-2, Safety- EN 62040-1, Performance- IEC 62040-3, Certifications: BIS,OSHAS,CE,PeP,RoHS, ISO 9001 & ISO 14001 ,Warranty :3 years on site warranty from the date of installation of ups and 4 year for battery complete.
1
-
-
OD2352/2024-2025:Supply, installation, testing and commissioning of 230V AC. 50HZ , 3.5 KVA inverter having digital frequency control circuit with on load automatic changeover from mains to inverter circuit on mains failure and vise versa on restoration of mains supply . The unit shall have an in-built battery charger with solar charging option of suitable capacity having automatic cut off circuit on battery attaining full charge . The unit should also have overload trip with audio visual indication & automatic reset on removal of overload, LED indication for Mains ON, charging ON, Overload Trip & inverter ON and Output ON/OFF switch on the front panel .Preferred make LUMINOUS / APC /MICROTEK.
1
-
-
OD2353/2024-2025:Supply and installation of Inverter battery 12V 100 Ah tubular type conforming to ISO 9001:2008 and ISO 14001:2004 suitable for 3hours backup on full load with suitable battery rack complete as required.Preferred make of EXIDE / LUMINOUS / AMRON
3
-
-
OD2354/2024-2025: Supply Push Button Telephone. Preferred makeBeetel C-51 CLI Phone
1
-
-
OD2355/2024-2025:Supply Push Button Telephone Preferred make; Beetel C-11
5
-
-
OD2356/2024-2025:Supply, installing, commissioning of manageable switch SG350-28-K9 or equivalent 28 PORT GIGABIT manageable switch having 24 x 10/100/1000 + 4 x Gigabit SFP (2 combo) , L3 - Managed, 24x GbE (1000Base-T) | 4x SFP | Managed, VLAN-fähig, Rackmount, Enclosure Type:- Rack-mountable Voltage Required :-AC 120/230 V (50/60 Hz), Switching Capacity should be 56 Gbps,4096 active VLAN's ,RAM-512MB,Flash memory-256 MB flash,switch should be Manageable through CLI, web Interface and SSH.
1
-
-
OD2357/2024-2025:Supply and installation of 12U/600 Rack with Bracket wall mounting type Rack with 1Ph, 230V, 8A, 2U standard rack mount power distribution unit with 6 X 5A plug socket, Cantilever Shelf(3Nos), cable alley and fan Preferred make:Netrack or equivalent
1
-
-
OD2358/2024-2025:Wiring the patch panel and Configuring of Manageable network switch complete
1
-
-
OD2359/2024-2025:Supply of Cat 6,1 meter patch cord
10
-
-
OD2360/2024-2025:Supply of Cat 6,2 metre patch cord
10
-
-
OD2361/2024-2025:Supplying and fixing following Modular base & cover plate on existing CMS 105X50mm etc. as required.6 Module base and cover plate.
11
-
-
OD2362/2024-2025:Supplying and fixing following Modular base & cover plate on existing CMS 105X50mm etc. as required.3 Module base and cover plate.
8
-
-
OD2363/2024-2025:Supplying and fixing following Modular base & cover plate on existing existing CMS 105X50mm. as required.1 or 2 Module base and cover plate
10
-
-
OD2364/2024-2025:Supply and fixing 105 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess including switch plate
70
-
-
OD2365/2024-2025:Supply and fixing 80 x 50 mm UPVC Cable Management System with base and lid LEGRAND or equivalent along with all required accessories as per the site condition on surface/recess including switch plate
20
-
-
OD2366/2024-2025:Identifying cables, supply and crimping RJ 45/RJ 11 cable jack on the cable end and giving connection
34
-
-
OD2367/2024-2025:RJ 45 Frame
10
-
-
OD2368/2024-2025:CAT 6 RJ 45 computer data socket
10
-
-
1.18.1:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair
112
-
-
1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
7
-
-
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
232
-
-
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
20
-
-
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV
grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
8
-
-
14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
7.5
-
-
OD2369/2024-2025:Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
28
-
-
OD2370/2024-2025:Supplying and making end termination nickel plated single compression brass cable gland for 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
4
-
-
OD2371/2024-2025:Supply and fixing Cable Junction Boxes IP 67 for outdoor applications (with knock outs for cable entry - Black Colour) suitable for cable sizes 2.5 sq.mm ,88 X 88X 53 mm Hensel model No KF 5025 B or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
2
-
-
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
20
-
-
7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
2
-
-
2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
6
-
-
OD2372/2024-2025:Supply of Single channel VHF wireless microphone
2
-
-
OD2373/2024-2025:Supply of 6.35mm Phonoconnector
2
-
-
OD2374/2024-2025:Supply of XLR male connector
2
-
-
OD2375/2024-2025:Supply of best quality mic cable
10
-
-
OD2376/2024-2025:Supply and installation of universal Wall Flat panel full-motion TV mount. Fits most 40" - 75" flat panel displays mounting clamp including 15 m HDMI, 15m VGA and 15 m Power cable.
1
-
-
OD2377/2024-2025:Supply and installation of ultra HD smart LED TV 55'' 3 Hdmi Ports For Seamless Connectivity With External Devices | 1 X Usb-A Usb Ports To Connect Hard Drives Or Other Usb Devices |Wi-Fi | Bluetooth | Anynet+ (Hdmi-Cec)| Ethernet (Lan) Port| Rf In (Terrestrial / Cable Input / Satellite Input).. Preferred make Samsung, LG, Sony etc..
1
-
-
OD2378/2024-2025:Supply and testing of DPR125W Mixer recordable Amplifier with five Mic inputs, built-in MP3 recorder player and USB with large display, SD/MMC card reader, LCD supplied and separate remote complete as required preferred make Ahuja or equivalent.
1
-
-
OD2379/2024-2025:Supply of Digital Lectren with Mic having built in RMS 60W Amplifiers, built in three 4 inch Woofer & 2 inch Tweeter, One Flexible Gooseneck Microphone, One LED goosenecklight, VHF hand held microphones, MIC/lineoutput for speaker and line out., AC Power switch and light power operation, steel body and bottom.
1
-
-
OD2380/2024-2025:Supply of gooseneck microphone PGM 625 with microphone stand PGB 10 and stand APS 302Phantom power of following specifications, Frequency response: 50-16,000 Hz, Sensitivity-45 DB plus or minus 3 DB Impedance: 2000 ohm plus or minus thirty percent, Power required: 9-52 V Phantom supply
1
-
-
OD2381/2024-2025:Supply installation testing and commissioning of fully automatic servo motor type AC voltage regulator capacity 2KVA specially designed for audio equipment having over votage and under votage correction, short circuited protected, no waveform distortion, low noise operation, high overload capability Fail Safe Circuit Protection: Cuts off the power to connected equipment in case of component failure, Time Delay: 30 seconds maximum, Input Voltage Range: 180V to 265V, complete as required.
1
-
-
OD2382/2024-2025:Supply, installation testing and commissioning of 30 W speaker SMX 302/302 T with input power 30 WRMS, Power taps 30W on 8 ohm, 30/15/7.5 w on 100V, Frequency response 80-20000 Hz preferred make Ahuja or equivalent.
4
-
-
OD2383/2024-2025:Supplying and installation of suitable clamp for outdoor unit split Air condition system with all fixing accessories complete as required.
4
-
-
OD2384/2024-2025:Installation Testing and commissioning of 1. to 2 Tonne departmentally supplied split type air conditioning unit in suitable location as directed by the engineer in charge with all fixing accessories complete as required.
4
-
-
OD2385/2024-2025:Supply, Testing and commissioning of Wall hanging type Voltage stabilizer of Single phase 230V, ac, 50Hz,4000 VA suitable for 170 to 260V input voltage range preferred make of V- GUARD/ MICROTEK for 1.5 T Inverter AC
4
-
-
OD2386/2024-2025:Supply of 1.5 Ton 5 star rated inverter type split AC with Multi Adjustable Mode ,Anti Microbial Air Filtration,100% Copper,ISEER 5.0,230V,50Hz,1 Phase supply and with LCD remote ,battery and high EER rotary BLDC compressor operating voltage of 110-285 V,etc complete .The unit shall a warranty of 3 years preferred make Voltas Model 4503453 / 185V Vectra Elite or equivalent .
4
-
-
OD2387/2024-2025:Providing and fixing 12 SWG insulated GI wire for service wire binding along with service line complete with all accesaries complete as required.
45
-
-
OD2388/2024-2025:Painting letters or figure of following sizes with enamel paint as identification mark to SB,DB, panel board etc as required. 2.50 cm, 4 cm or 5cm height.
50
-
-
OD2389/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
20
-
-
OD2390/2024-2025:Documentation charge for getting new KSEB connection including preparation essential load calculation drawing other documentation work including submission of application , lessening work complete as required.
1
-
-
Civil Work
-
-
-
5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements