Harbour Engineering Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 24,360Document Cost
₹ 2,150Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HED_684863_1Bid Award Id
ViewTender No
HED/CEHED/TR/280/2024_6_1_1/1Tender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
72
-
-
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
60
-
-
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
524
-
-
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
96
-
-
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
372
-
-
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
12
-
-
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
24
-
-
1.23.1:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
12
-
-
1.23.4:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet
12
-
-
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
24
-
-
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
12
-
-
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
24
-
-
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
96
-
-
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
24
-
-
1.49:Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
50
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
48
-
-
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
48
-
-
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
24
-
-
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
24
-
-
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2
-
-
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
4
-
-
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
50
-
-
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
1.8
-
-
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
60
-
-
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
2
-
-
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
6
-
-
90.3.1:Conveyance, installation, testing and commissioning of pre-wired fluorescent light fittings with all accessories and fluorescent lamps of all types directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required
36
-
-
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
25
-
-
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
12
-
-
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
50
-
-
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
1260
-
-
90.14.7:Supply and providing copper earth bus in the panel board
600
-
-
90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm
150
-
-
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
24
-
-
OD636/2024-2025:Supplying 20W LED Tube with fixtures Essential LED tube 1200 mm 20W 865 T8 API Philips or equivalent .
36
-
-
OD933/2024-2025:Providing and fixing 12 SWG insulated GI wire for service wire binding along with service line complete with all accessories complete as required.
90
-
-
OD3684/2024-2025:Supply and installing 7+/-2W LED bulkhead fitting (IP 65), housing made of die cast aluminium with 6500K colour temperature with a lumen output minimum 100lumen/Watt, CRI>80,beam angle 120 degrees, suitable for outdoor applications, including all connections etc. as required. Make -Philips -Vista glow or equivalent
12
-
-
OD3694/2024-2025:Supply and fixing IP 65 HENSEL 1 row 9 module( Model No KV 7109) KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws. Inter connection using 4 sqmm copper wire and all fixing accessories complete as required.
24
-
-
OD3685/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof 300x600x170 mm, Hensel make polycarbonate Enclosure - IP66 size 4 box K0400 or equivalent in wall with all fixing accessories and cutting holes for bus bar arrangement and sealed with suitable binding agent complete as required.
6
-
-
OD3691/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof 300x300x170 mm, Hensel make polycarbonate Enclosure - IP66 size 2 box K0200 or equivalent in wall with all fixing accessories and cutting holes for bus bar arrangement and sealed with suitable binding agent complete as required.
2
-
-
OD3687/2024-2025:Supply and installation of wall mounting cubicle type Hensel make K0300 or equivalent thermoplastic polycarbonate energy meter enclosure with hinged lid 450 x 300 x 170 mm , IP66 with base plate for fixing KSEB meter, cut out & Neutral link and 20A , 10kA DPMCB, C curve , with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing 1No 20A,10kA ,DP MCB C curve , 1 No 32A HRC fuse units with 20A HRC fuse link and 1No 32A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire and sealed the joint with suitable sealing agent,etc. The inter connection should be done using 4sq.mm copper wire.complete as required.
24
-
-
OD3692/2024-2025:Supply and installation of wall mounting cubicle type Hensel make mi9410 or equivalent thermoplastic polycarbonate energy meter enclosure with hinged lid 315 x 600 x 214 mm , size 4 , with supply and fixing of 40 A ,16 kA,4P,MCCB With BUC rotary drive kit,inter connection using 10 sqmm pvc insulated copper wire and 2A SPMCB with RYB Indicator lamp and wiring this circuit with 2.5 sqmm copper wire. Necessary holes are to be provided in the box for entry and exit of wire and sealed the joint with suitable sealing agent,etc. all fixing accessories complete as required.
2
-
-
OD3693/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
150
-
-
OD798/2024-2025:KSEB Documentation charge for getting new connection connected work including preparation of drawing ,file work submitting application etc complete as required.
24
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements