Harbour Engineering Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 18,400Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_HED_550776_1Bid Award Id
ViewTender No
45/HEED/2022-23/STender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Fabricating and supplying special clamping arrangement for fixing an asymmetrical beam integral LED flood light on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm,10mm, or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxy-based industrial primer of approved quality and two coats of epoxy paint of approved color as per drawing.
16
-
-
Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armored copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
24
-
-
Supply and fixing Cable Junction Boxes IP 67for outdoor applications (with knockouts for cable entry - Black Colour) suitable for cable sizes 2.5 sq. mm,93 X 93X 62 mm Hensel model No KF 0202 B or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq. mm 5 Pole 1 No, Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages, etc. as required.
20
-
-
Conveyance, installation, testing, and commissioning of departmentally supplied floodlight luminaire with a lamp on the existing tubular post of height up to 15m from ground level. All bolts and nuts shall be Stainless steel.
16
-
-
Supply and fixing IP 65 HENSEL 1 row 9 module( Model No KV 7109) KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws.
6
-
-
Supplying LED Flood light luminaire Schreder make CITY or equivalent 40W LED,=3500 lumen, electrical Class I, extruded aluminium body, an extra clear toughened glass protector, IK 08 impact resistance permanently robotically sealed onto the body with a silicone sealant, closed at one end by an end cover and the other end by a frame and door assembly. IP 66 optical & control gear compartments with direct access to control gear, bracket suitable for a wall or high mast mounting, each LED with a specific lens for area lighting the luminaire shall have a CCT of 5700K and Colour Rendering Index 70, a driver (efficiency 85%) with internal surge protection of 4/4 kV , Power Factor 0.95, a residual flux of 70% (L70) @ 50,000 hours at Ta 500.modular family street light luminaire,System efficacy= 95 lumen/watt, Driver efficiency = 85%, Power factor 0.90,colour rendering index70 and cool white light - 5700ºK, with five year warranty for the light fitting.
8
-
-
Supply and fixing of LED flood light luminaire with a system wattage of 100W electrical class 1. The luminaire shall have an extruded anodized aluminum body and heat sink made of stretched Aluminum(6063). The luminaire must have a polycarbonate lens with light transmittance greater than 90% with a flammability rating of UL 94 V0 IP 66 tightness for the optical compartment and IP67 tightness for control gear compartment shall be ensured and impact resistance of IK 10 shall be ensured. The mounting bracket shall be made of cold-rolled steel sheet powder coated. The luminaire shall have a system efficiency of 120lm/w, CCT of 5700k and colour rendering index (CRI =70. The Driver efficiency=90% has internal surge protection of 4/6 kV. Power factor =0.95 a residual flux of =70% @ 50000 hours K flood 100W CWLED or equivalent
4
-
-
Conveyance, installation, testing, and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp, etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring, etc as required
12
-
-
Supply, fabrication, conveyance and fixing of 40 mm dia Medium class GI pipe with clamps made from 20 x 3 mm MS flat bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of epoxy paint over a coat of epoxy primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
36
-
-
Supply Conveyance, installation, testing and commissioning of SID or equivalent make Street light luminaire, 20W LED, IP66 optical & control gear compartment, die cast aluminium painted housing,anti UV Polycarbonate protector with in built individual lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy 105 Lumen/W at Ta 25,Total 2100 lumens. Lifetime residual flux @ Tq 35C @ 50,000 hours = 70%, Ta = 50C, in built surge protection of 4kV (in Differential and Common mode), Power Factor 0.95, Colour Rendering Index 70 and Cool white light (5700K).THD10%,5 year warranty for the luminaire.
6
-
-
Supply of surface mounting corrosion-resistant Waterproof industrial lighting luminaire Philips WT201C LED44S 6500 PSU L120 S2 (Philips) or equivalent with 36 W LED lamp
18
-
-
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
16
-
-
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm
20
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
2
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C
2
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
10
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
6
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
2
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
2
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
2
-
-
Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
18
-
-
Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.
100
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
31
-
-
Engaging labourers for dismantling the light fittings, checking the electrical installations, rectifying defects, etc if any as per the direction of the departmental officers at the site - Wireman
15
-
-
Engaging labourers for dismantling the light fittings, checking the electrical installations, rectifying defects, etc if any as per the direction of the departmental officers at the site - Beldar
12
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
220
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
50
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing asrequired.
24
-
-
Supply & installation of outdoor terminal box with hinged lids have IP65 protection, size - 315 x 600 x 214 mm, including all connections etc as required.Terminal box make - Hensel or equivalent.
4
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
10
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
21
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
6
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
216
-
-
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
0.5
-
-
Supply and providing 15mm pvc gland at the junction box including drilling necessary holes as required
32
-
-
Providing and fixing 10.00 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
110
-
-
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
50
-
-
Providing and fixing 12 SWG insulated GI wire for service wire binding along with service line complete with all accesaries complete as required.
250
-
-
Scaffolding Charges for dismounting the light fittings from the existing tubular pole
4
-
-
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
50
-
-
Supply and drawing PVC / Xlpe Insulated and PVC Sheathed Industrial 3 Core 1.5 sqmm Flat Submersible Cable with Bare Bunched Copper Conductor with Voltage Grade 1100 Volts as per IS:694/2010
20
-
-
Supply and fixing 3m height 65mm Heavy duty ( class C) G.I. Pipe having ISI mark and of approved quality with 12mm thick GI flange and Table E dummy Flange suitable for 65mm heavy duty C class pipe at the top of the post and 75mm x 40mm C channel welded on the top of the flange with bolt holes to fix two number of flood lights by clamping 2 sets of clamps made out of 50 x 6 mm GI flat using 8 Nos 12mm stainless steel screws. Thepost shall be fixed by demolishing concrete for exposing reinforcement and supply and providing 12 mm thick MS flange of OD suitable for 50 mm heavy duty GI pipe with 4 numbers of 20 mm dia,75mm long GI dip galvanised anchor bolts for embedding in the concrete and the post is to be painted with two coats of best quality industrial epoxy paint over two coats of industrial epoxy primer. Cable entry provision by Inverted Y arrangement using heavy duty GI pipe and suitable flanges at the top for taking out cables and fixing departmentally supplied flood light and junction box making good the damages by filling the hole with 1:1.5:3 concrete mix , plastering ,colour washing etc complete
4
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
150
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
50
-
-
KSEB Documentation Charge
18
-
-
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
0.5
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements