Harbour Engineering Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 17,123Document Cost
₹ 1,510Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HED_680334_1Bid Award Id
ViewTender No
HED/CEHED/TR/289/2024_6_2_1/1Tender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
286
-
-
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
10
-
-
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
85
-
-
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
235
-
-
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
17
-
-
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
68
-
-
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
17
-
-
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
17
-
-
OD490/2024-2025:Supplying 16 W LED Tube with box type fixtures Essential LED tube 1200 mm 16W 840 T8 API Philips or equivalent
17
-
-
OD491/2024-2025:Supply and fix LED Bulk Head fitting 10W with Aluminium die-cast housing and polycarbonate optic materials including connection etc as required. The luminaire shall have IP66 protection, luminous flux 1100 lm, luminous efficiency 110 lumens/watt, cool daylight colour and 6500k colour temperature PHILIPS Endura LED Bulk Head model WT202W LED10S CW PSU S3 PC or equivalent
17
-
-
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
17
-
-
OD492/2024-2025:Supply and fixing 7/9 W LED ,BC, lamp OSRAM or equivalent
17
-
-
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
17
-
-
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
17
-
-
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
34
-
-
OD493/2024-2025:Supply and fixing IP 65 HENSEL 1 row 9 module( Model No KV 7109) KV thermoplastic circuit breaker boxes with PE + N Terminals on the surface using suitable size stainless steel screws.
17
-
-
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
0.6
-
-
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
2.8
-
-
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
17
-
-
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
51
-
-
OD2463/2024-2025:Supply installation testing and commissioning of wall mounting type single phase metering panel made of polycarbonate outdoor type metering panel board made of thermo plastic polycarbonate enclosures, the enclosure shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The Degree of Ingress Protection IP 65 shall be in accordance with IEC 60529.The panel shall be comprising of the following and shall be fully wired as per latest electrical standards and all necessary accessories, ready to use(Make:Hensel or equivalent). Incoming:63A DP MCB 10kA - 1No Outgoings:Provision for fixing 1Phase KWH meter – 5Nos, 32A HRC Fuse base with links - 5Nos,32A Neutral link – 5Nos,32A DP MCB 10kA – 5Nos
1
-
-
OD2464/2024-2025:Supply installation testing commissioning of wall mounting type, customized, factory made, Single Phase Metering Panel made of thermoplastic poly-carbonate enclosures. The enclosure shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The Degree of Ingress Protection IP 65 shall be in accordance with IEC 60529. The panel shall be comprising of the following and shall be fully wired as per latest electrical standards and all necessary accessories, ready to use (Make: Hensel or equivalent).<br>Incomer: 63 A DP MCB -1 nos . Outgoing 32 A DP 10 kA MCB-4 nos, 32 A HRC Fuse links with neutral link- 4 nos, and provision for Mounting Single phase energy metre-4nos.
3
-
-
90.12.24.2:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.4 sq mm
204
-
-
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
30
-
-
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
8.5
-
-
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
20
-
-
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
56
-
-
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
24
-
-
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
3.4
-
-
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
4
-
-
OD512/2024-2025:KSEB Documentation Charge for getting new connection including all file work preparation of statutory drawing load calculation etc complete as required.
17
-
-
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
4
-
-
1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
12
-
-