Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Harbour Engineering Department - HED Tender
Eprocure
Opening Date29 Jul 2019
Closing Date6 Aug 2019
Tender Amount₹ 19,18,419
Costs
EMD
₹ 48,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Electrification Of Valiathura Pier
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_HED_290058_1Bid Award Id
ViewTender No
33/HESC/2019-20/STender Authority
Harbour Engineering Department ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm Hensel make, Mi2410 thermoplastic box with hinged door - IP66 , IK 10 outdoor enclosure with provision for fixing Astronomical Time switch,MCB and Contactor using DIN rail.
1
-
-
Supplying and fixing 2 amps to16 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .Single pole
13
-
-
Supplying and fixing 2 amps to16 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Tripple pole
9
-
-
Supplying and fixing Double pole 4 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing JB complete with connections, testing and commissioning etc. as required.
23
-
-
Supply and fixing 3 pole power contactor , 25A, AC3 duty , epoxy impregnated coil voltage 240V (MNX 25 or equivalent) in the existing enclosure.
2
-
-
Supply and installation of Astronomical time switch with 2 channel - DIN Rail mounted with automatic calculation of sunrise and sunset times for the whole year & Offset for adjusting of sunrise and sunset times, 10 year power reserve, 2 modules (width 35 mm), 2 independent relay having capacity of 10A at power factor= 0.8, rail mounted astronomical time switch with factory-set time; text-oriented user guidance in the display, city database, automatic summer/winter time changeover, maximum offset +/-120 mins, weekly program plus, elapsed-time counter for light sources, ON/OFF permanent, option for night break selection for energy savings, relays should have external input supply option to override the switching status. Duo Fix screw less terminals, zero cross switching, two way switch 16A/250VAC; sealable transparent cover &PC programming.
1
-
-
Supply and fixing 16A automatic phase selector switch , 3ph + N as incomer and one single phase output
1
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
96
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
1019
-
-
Supply of 3 core 2.5 sq mm PVC insulated and PVC sheathed submersible copper cable
69
-
-
Supply of 4 core 4.0 sq mm PVC insulated and PVC sheathed armoured copper Power cable
719
-
-
Supply of 4 core 6.0 sq mm PVC insulated and PVC sheathed armoured copper Power cable
240
-
-
Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
87
-
-
Supplying and laying of 63/50 mm size DWC HDPE pipe ISI
marked along with all accessories like socket, bend, couplers
etc. conforming to IS 14930, Part II complete with fitting and
cutting, jointing etc..direct in ground (75 cm below ground level)
including excavation and refilling the trench but excluding sand
cushioning and protective covering etc., complete as required.
68
-
-
Supply of 50/38mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II,
118
-
-
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
36
-
-
Supplying and making end termination nickel plated single compression brass cable gland for 4 core 4 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
37
-
-
Supplying and making end termination nickel plated single compression brass cable gland for 4 core 6 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
2
-
-
Supplying and making end termination nickel plated single compression brass cable gland for 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
8
-
-
Supply of anchor type Glass Reinforced Plastic lighting Pole of nominal height 3.5 m,bottom OD147 mm,Top OD 114mm, suitable for vertical mounting Ø60mm post top LED luminaire as per IS 2713-1980,IS 875(part 3)-1987,IS 6746,ANSI C 136.20 1990,ASTM D 4923-01,ASTM D 790,ASTMD 695 average thickness of 5mm ,dielectric strenghth 7.3 KV/mm,specific gravity 1.3kg/cm2,impact resistance 200KJ/m2,water absorption0.5%.The pole shall be painted with two coats of polyurethane paint.
17
-
-
Supply of burial type Glass Reinforced Plastic lighting Pole of overall length 3.5 m,bottom OD 155 mm,Top OD 114mm, suitable for vertical mounting Ø60mm post top LED luminaire as per IS 2713-1980,IS 875(part 3)-1987,IS 6746,ANSI C 136.20 1990,ASTM D 4923-01,ASTM D 790,ASTMD 695 average thickness of 5mm ,dielectric strenghth 7.3 KV/mm,specific gravity 1.3kg/cm2,impact resistance 200KJ/m2,water absorption0.5%. The pole shall be painted with two coats of polyurethane paint .
6
-
-
Supply and fixing Cable Junction Boxes IP 66 for outdoor application( with metric knock outs for cable entry - Black Colour)) suitable for cable sizes upto 16/25 sq.mm ,200 X 160 X 98 mm Hensel model No KF 5255 or equivalen and accessories for Cable Junction Boxes such as Copper Terminal Set including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
23
-
-
Erection of departmentally supplied Glass Reinforced Plastic lighting Pole on1:2: 4 RCC foundation in well steinings of one number of 0.30m depth and 0.75 m diameter,2 numbersof 0.3 m depth and 0.6 m diameter and a muffing of 0.6mx6 with height of 0.8 m. The post shall be erected on 4 numbers of 20mm dia foundation bolts of length 1.5m and base plate suitable for 155mm OD GRP pipe at the bottom of the post and 65 D flange on the muffing with 4 nos of 20mm bolt holes and 3Nos of 20mm nuts per bolt. Muffing to be plastered using cement mortar 1:4, 12mm thick colour washing 2 coats using approved colour etc. complete..All steel items shall be hot dip galvanised.
6
-
-
Erection of departmentally supplied Glass Reinforced Plastic lighting Pole in 1:1.5:3 RCC foundation and a muffing of 0.60x0.60m with height 0.80m clamped on the RCC pillar using 50x 50x6mm angle iron clamp and mounted on the concrete base using 200 x 200mm x 10 mm SS base plate and 4 numbers SS anchor bolt and nuts . Muffing to be plastered using cement mortar 1:4, 12mm thick colour washing 2 coats using approved colour etc. complete.All steel items shall be hot dip galvanised.
17
-
-
Supply installation testing and commissioning of Keselec make Symmetrical LED based post top luminaire (SOFIA NW LED SYM 30W, IP66) electrical class 1, with a grey (RAL 7037) painted high pressure die cast aluminium body, an SLX polycarbonate (anti UV) protector (for optimal luminous flux & IK 10 impact resistance), permanently sealed onto the body to achieve separate IP 66 optical & control gear compartments (for better thermal dissipation) with direct access to control gear, suitable for vertical mounting (Ø60mm), each LED with a specific lens for symmetric or asymmetric photometric distributions. . The luminaires shall have CCT of 4000K , system lumens-2485,colour rendering index 70, driver efficiency of 85% with an inbuilt surge protection of 4/4 kV,external surge protection of 10/10kV..
23
-
-
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1
-
-
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
50
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
5
-
-
Supply and providing 6Kg stored pressure ABC Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
1
-
-
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
10
-
-
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
873
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
31
-
-
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
30
-
-
Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
62
-
-
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) & 4.0mm (8 SWG) earth conductor including crimping etc. as required.
62
-
-
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
2
-
-
Providing and fixing 50 mm dia nominal bore B class G.I. pipes with ISI mark complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.
6
-
-
Providing and fixing earth bus of 25 mm X 5 mm copper strip on surface for connections etc. as required.
1.2
-
-
Supply and providing 8 SWG coated GI wire
2
-
-
Wiring for light point/ fan point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
11
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
11
-
-
Supplying and fixing suitable size G.I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
2
-
-
Supplying and fixing suitable size G.I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
2
-
-
Supplying and fixing 1 or 2 Module (75mmX75mm) size/ modules, thermoplatic box alongwith modular base & cover plate for modular switches in recess etc as required.
4
-
-
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
4
-
-
Supplying and fixing 20mm medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
33
-
-
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
18
-
-
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
11
-
-
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4.0 sq. mm
6
-
-
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required .4 x 4.0 sq. mm
2
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 10 sq. mm earth wire
5
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
3
-
-
Supplying LED luminaire Philips WT 201 C LED 20S - 6500 PSU L 120 IP 65 or equivalent
5
-
-
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
5
-
-
Supply and installation of suitable size Stainless Steel rod type fan clamp as per IS 732 as required.
4
-
-
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
4
-
-
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan (Crompton Greaves High Speed, Orient or equivalent) excluding resistance type regulator,
4
-
-
Supply and installation of wall mounting cubicle type dust and vermin proof CAPE make CA 32 , 270x180x170mm IP66,IK 10 Glass fibre reinforced polyester enclosure with provision for fixing 20A , 16kA TP MCCB, with rotary handle. Supply and providing 1No of 20A,16kA ,Triple Pole MCCB with rotary drive kit . Necessary holes are to be provided in the box for entry and exit of wire. The inter connection should be done using 6.0 sq.mm copper wire.
1
-
-
Supply and fixing IP 65 outdoor installation CAPE 9 module( Model No Aki 09) 200x200x122mm Thermoplastic polycarbonate MCB distribution board with PE + N Terminals on the surface using suitable size stainless steel screws.
1
-
-
Supplying and fixing 40 A double pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, 40A residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supplying and fixing brass batten/ angle holder including connection etc. as required.
1
-
-
Supply and fixing 7/9 W LED lamp OSRAM / Philips or equivalent
2
-
-
Supply and fixing cast aluminium stove enameled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for LED Lamps including connection etc as required.
1
-
-
Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
4
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
0.65
-
-
Centering and shuttering including strutting, propping etc. and removal of form for : Roof
5.65
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
25
-
-
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
33.6
-
-
Painting with 2 Coats of Industrial based Epoxy primer of approved brand and manufacture on steel galvanised iron/steel works (2 Coats)
4
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
30
-
-
Supplying and fixing 1.0 m x 2.2m door using 14G powder coated Aluminium frame and 3mm thick outdoor purpose ACP with fixtures like hinges,Tower bolt and pad lock etc.
1
-
-