Guruvayur Devaswom Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 17,100Document Cost
₹ 1,505Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GD_671253_1Bid Award Id
ViewTender No
E3-6375/23Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Rewiring and providing yard lighting at Ayyappa Kshethra Mundur under Guruvayur Devaswom
BOQ Items
90.2.1.4
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control
ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
2
-
-
90.2.1.6
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined
plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light
points
7
-
-
90.2.1.7
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent
plug - Short point
7
-
-
90.2.1.8
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control
light point with 6A, plate ceiling rose - Medium Point
22
-
-
90.2.1.11
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control
ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator - Medium
Point.
20
-
-
90.3.20.3
Supply & installation of light fittings on TW round blockbrSupply, conveyance installation testing and
commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all
accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the
fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire
conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type
fixture
27
-
-
90.3.21.3
Supply & installation of light fittings on 'C/U' shaped flat iron bracketbrSupply, conveyance, installation,
testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete
with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS
flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper
conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.
as required.1200 mm 1X20W LED Lamp with box type fixture
3
-
-
od174344/2023_2024
Supply, installation , testing and commissioning of 300/305 mm light duty exhaust fan in metal body
working on 230V single phase A/C supply in the existing opening including making the holes to suit the
size of the above fan, fixing necessary bolt and nuts making good the damages etc. as required including
giving connections
1
-
-
od174345/2023_2024
Supply installation testing and commissioning of 35W LED Street light fitting with IP66
protection,120lm/w,PF0.95 THD10% pressure die cast aluminium body, PC lens for optium light
spread, potted driver,life 50000@L70 on exsisting GI pipe and giving connection.LM79&80 certificates to
be produced mentioning chip manufacturer.(Wipro Dot LR08/equivalent
1
-
-
od174346/2023_2024
Supply installation testing and commissioning of LED Flood light fitting 60W with efficacy upto
150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty
LED Chip make Cree/Lumilled/Nichia Power factor 0.9 and giving connection.LM 79&80 certificates to be
produced.(Aston prime K-lite Id 4200/equivalent)
14
-
-
90.3.18.3
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and
welded to shape and fixing the same to wall / parapet using clamps as noted along with each size,
painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the
damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
4
-
-
od175393/2023_2024
Supply and installation of suitable size MS clamp fabricated from flat iron 25 x 6 mm, 300mm long x 2
Nos suitable for fixing 32/40mm GI pipe/as bracket for fixing Flood light on KSEB pole, neatly painted
with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
4
-
-
od175394/2023_2024
Supply and providing 2X2.5 sq.mm PVC insulated and PVC sheathed weather proof aluminium wire and
giving connection.
10
-
-
od174347/2023_2024
Supply, conveyance, installation, testing and cmmissioning of ceiling fan of all sizes using standard
accessories including wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V
grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm
sweep 5 star rated BLDC ceiling fan with service value greater than or equal to 6 complete with 260mm
down rod , canopies, shackeles and blades working on 230V/240V single phase A/C.
22
-
-
90.4.2
Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm,
150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat
of red oxide primer as per IS 732 as required.
20
-
-
1.47
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting
etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less
shall be ignored)
200
-
-
1.58
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
6
-
-
od174512/2023_2024
Supply and providing 5/7 W LED bulb on exsting fitting.
6
-
-
od174513/2023_2024
Dismantling the exsisting light/fan/call bell point etc.with pipe wire,fittings,switches ,boxes and conveying
to section store.
24
-
-
od174514/2023_2024
Supply and fixing 200mm plastic shade on exsisting battan/bracket fitting as required.
6
-
-
90.4.8
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including
plastering colour washing etc. as required.
1
-
-
90.6.5.11
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq
mm
60
-
-
90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm
160
-
-
90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required25 mm
10
-
-
1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
20
-
-
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
40
-
-
1.17.13
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
40
-
-
90.6.6.2
Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat
cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving
necessary connections of the following sizes.2.50 sq mm
20
-
-
1.17.15
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
20
-
-
1.17.31
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
10
-
-
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.5/6 amps switch
1
-
-
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
6
-
-
90.10.3.15
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )32A DP switch with indicator
3
-
-
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
3
-
-
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
6
-
-
1.26
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular
plate as required.
1
-
-
1.27.1
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.1 or 2 Module (75mmX75mm)
3
-
-
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.3 Module (100mmX75mm)
2
-
-
1.27.5
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.8 Module (125mmX125mm)
1
-
-
1.28.2
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.3 Module
4
-
-
90.10.1.3
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )3 module
moulded plastic box on surface
4
-
-
90.11.1.10
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP
42/43)
2
-
-
90.11.1.15
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB
with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP
42/43)
1
-
-
2.3.2
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8
way, Double door
1
-
-
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12
way, Double door
1
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
34
-
-
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
3
-
-
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
14
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
2
-
-
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
2
-
-
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
2.14.1
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.25 amps
2
-
-
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
2
-
-
90.12.5.1
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.2 core 4 sq mm
110
-
-
90.12.5.2
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.2 core 6 sq mm
35
-
-
90.12.5.39
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.4 core 6 sq mm
25
-
-
90.12.7.1
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with
factory made clamp
15
-
-
90.12.7.2
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with
factory made clamp
15
-
-
90.12.7.39
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with
factory made clamp
60
-
-
90.12.9.2
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of
HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all
required accessories in ground in the existing trench50/38 mm or nearest size
80
-
-
90.12.10.2
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or
nearest size
100
-
-
od174699/2023_2024
Supply installation testing commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70mm
top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x12mm suitable
for wind speed as per IS 875 Part III round arm bracket suitable providing 6 nos LED luminairs including
connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete 5 Meters
(Bajaj/Equivalent)br
2
-
-
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
with charcoal/ coke and salt as required.
2
-
-
5.15
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
8.4
-
-
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
230
-
-
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
220
-
-
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
30
-
-
90.16.2.1
Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including
excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
10
-
-
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.00 mm (14 SWG)
30
-
-
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
6
-
-
14.1
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m
including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead
of 50 metres.
0.6
-
-
14.10
Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as
required (excluding reinforcement).
0.6
-
-
14.12
Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
0.5
-
-
5.22.3
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelCold twisted bars
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements