Guruvayur Devaswom Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GD_671897_1Bid Award Id
ViewTender No
E3-6377/23Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Rewiring EI Ground floor of Main block and campus lighting around main block Sree Krishna College Guruvayur Devaswom
BOQ Items
90.2.1.11
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control
ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator - Medium
Point.
105
-
-
90.2.1.12
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Call bell point
with piano type 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Medium point
2
-
-
90.2.1.13
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined
plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light
points.
35
-
-
90.2.1.14
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent
Plug - Medium Point
10
-
-
90.3.20.3
Supply & installation of light fittings on TW round blockbrSupply, conveyance installation testing and
commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all
accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the
fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire
conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type
fixture
98
-
-
90.3.21.3
Supply & installation of light fittings on 'C/U' shaped flat iron bracketbrSupply, conveyance, installation,
testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete
with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS
flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper
conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.
as required.1200 mm 1X20W LED Lamp with box type fixture
66
-
-
90.3.24.3
Supply & installation of light fittings suspended on ball & socket arrangement with 19 mm down
rodbrSupply, conveyance, installation, testing and commissioning the light fittings of following types
made of .5mm thick CRCA sheet accessories and lamps etc. including supplying and fixing ball and
socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm
length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex
wire conforming to relevant ISS or extending the original wiring and giving connections etc. a
required.1200 mm 1X20W LED Lamp with box type fixture
35
-
-
od172071/2023_2024
Supply, installation , testing and commissioning of 300/305 mm heavy duty exhaust fan 900 rpm in metal
body working on 230V single phase A/C supply in the existing opening including making the holes to suit
the size of the above fan, fixing necessary bolt and nuts making good the damages etc. as required
including giving connections
9
-
-
od172072/2023_2024
Supply, installation , testing and commissioning of 150 mm light duty exhaust fan in plastic body with self
opening louvers working on 230V single phase A/C supply in the existing opening including making the
holes to suit the size of the above fan, fixing necessary bolt and nuts making good the damages etc. as
required including giving connections
2
-
-
od172073/2023_2024
Supply installation testing and commissioning of LED Flood light fitting 2X60W with efficacy upto
150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty
LED Chip make Cree/Lumilled/Nichia Power factor 0.9 and giving connection.LM 79&80 certificates to be
produced.(Aston prime K-lite Id 4201/equivalent)
9
-
-
od172074/2023_2024
Supply, conveyance, installation, testing and cmmissioning of ceiling fan of all sizes using standard
accessories including wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V
grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm
sweep 5 star rated BLDC ceiling fan with service value greater than or equal to 6 complete with 260mm
down rod , canopies, shackeles and blades working on 230V/240V single phase A/C.
105
-
-
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
70
-
-
90.4.2
Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm,
150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat
of red oxide primer as per IS 732 as required.
6
-
-
90.4.8
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including
plastering colour washing etc. as required.
11
-
-
90.5.1.3
Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving
connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC
sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original
wiring, earthing the MS box and making good the surface as required.Ding dong bell
2
-
-
90.5.1.8
Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving
connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC
sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original
wiring, earthing the MS box and making good the surface as required.Gong bell 150mm-without MS box
1
-
-
90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm
600
-
-
90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required25 mm
230
-
-
90.9.1.1
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.50x50mm Cable Management
System with base and lid
120
-
-
90.9.1.2
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.External angle 90 degree
8
-
-
90.9.1.4
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.Internal angle 90 degree
8
-
-
90.9.1.7
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.End cap
6
-
-
90.9.2.1
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the
following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the
wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with
base and lid
60
-
-
90.9.2.3
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the
following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the
wall and making good the damages in case of recessed installation as required.External angle 90 degree
6
-
-
90.9.2.5
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the
following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the
wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
6
-
-
90.9.2.8
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the
following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the
wall and making good the damages in case of recessed installation as required.End cap
6
-
-
1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
320
-
-
1.17.4
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
280
-
-
1.17.6
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
120
-
-
1.17.8
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.8 x 1.5 sq. mm
60
-
-
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
140
-
-
1.17.13
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
120
-
-
1.17.15
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
60
-
-
1.17.20
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
60
-
-
1.17.21
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
15
-
-
1.17.22
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
40
-
-
1.17.31
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
150
-
-
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.5/6 amps switch
84
-
-
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
25
-
-
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
207
-
-
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
25
-
-
1.26
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular
plate as required.
66
-
-
1.27.1
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.1 or 2 Module (75mmX75mm)
4
-
-
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.3 Module (100mmX75mm)
25
-
-
1.27.4
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.6 Module (200mmX75mm)
2
-
-
1.27.5
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.8 Module (125mmX125mm).
66
-
-
90.10.3.15
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )32A DP switch with indicator
2
-
-
90.10.3.33
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
2
-
-
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12
way, Double door
1
-
-
2.3.4
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16
way, Double door
2
-
-
90.11.1.10
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP
42/43)
2
-
-
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP
42/43)
3
-
-
90.11.1.15
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB
with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP
42/43)
1
-
-
90.11.1.19
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB
with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
100
-
-
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
8
-
-
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
16
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
3
-
-
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
5
-
-
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
2.14.1
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.25 amps
3
-
-
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
5
-
-
2.15.3
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C"
curve DP MCB complete with connections, testing and commissioning etc. as required.
3
-
-
2.18
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal
enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in
recess, with chained metal cover for the socket out let and complete with connections, testing and
commissioning etc. as required.
1
-
-
90.12.7.1
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with
factory made clamp
300
-
-
90.12.7.42
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with
factory made clamp
30
-
-
9.1.34
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 25 sq. mm (28mm)
2
-
-
od172698/2023_2024
Supplying and making end termination with brass compression gland and aluminium lugs for
brfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
brgrade as required.br2 X 4 sq. mm
18
-
-
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
with charcoal/ coke and salt as required.
2
-
-
5.15
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
8.4
-
-
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
900
-
-
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
300
-
-
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
60
-
-
90.16.1.4
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required4.00 mm copper conductor ( 8 SWG)
30
-
-
90.16.2.1
Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including
excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
10
-
-
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.00 mm (14 SWG)
300
-
-
90.16.5.2
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.65 mm (12 SWG)
20
-
-
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
6
-
-
90.16.5.4
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.4.00 mm (8 SWG)
6
-
-
od172578/2023_2024
Supply Installation testing and commissioning of Sub main distribution board 4 way with 3 pole MCCB as
incoming and 3 pole MCCB out going conforms to IEC 61539-2 IP43 on wall/floor using Anchor bolt nut
etc as required.(L&T/Equivalent)
1
-
-
od172582/2023_2024
Supply and providing Cable alley box suitable for 4 way sub switch board left/right side (L&T/equivalent
2
-
-
od172637/2023_2024
Supply and providing bottom cable alley box suitable for 4 way sub switch board using suitable nut bolt
etc as required.(L&T/equivalent)
1
-
-
od172583/2023_2024
Supply and providing Corner box suitable for 4 way sub switch board (L&T/equivalent)
4
-
-
od172584/2023_2024
Supply and providing metering extension box suitable for 4 way sub switch board with provision for
Ammeters Volt meter selector switch and indicators etc. as required.(L&T/Equivalent)
1
-
-
od172588/2023_2024
Supply and providing single phase digital Ammeter class1 and giving connection etc as
required.(L&T/equivalent)
3
-
-
od172589/2023_2024
Supply and providing 3 phase digital Volt meter 50-520V class1with selector switch and giving connection
etc as required.(L&T/equivalent)
1
-
-
od172591/2023_2024
Supply and providing Danger notice board of size 250X200mm with inscriptions(Both English and
Malayalam) and conventional skull and bone in Red color
1
-
-
od172592/2023_2024
Supply fixing LED Indicator red Green Black Yellow color 22.5mm cut out
2
-
-
od172593/2023_2024
Supply fixing LED Indicator Blue color 22.5mm cut out
1
-
-
od172594/2023_2024
Supply and fixing 160/5,15VA,class 1 CT unit using suitable bracket and giving connection.br
3
-
-
Evaluation Notes How It Works ?