Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 50,000Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GD_671956_1Bid Award Id
ViewTender No
E3-7796/2023Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
od98406/2023_2024
Providing e:bus interface for the software for up to eight Glass Touch devices. The e:bus Node is
supplied with voltage via an external adaptor or through Power-over-Ethernet (PoE). It is easily mounted
onto standard 35 mm DIN rails or via a suspension hole on the back on any solid vertical surface. The
SYMPL e:bus Node is a straightforward, reliable and easy to use interface solution for the
software.(Osram Traxon/Equivalent)
1
-
-
... More
od98407/2023_2024
Supply Installation testing and commissioning of A DMX based signal distributor with 2 channel interface
for DMX & RDM interface to be used with Master controller & lighting control software sympholight. It
provides 2 independent universes of DMX/RDM with 1024 channels. IP 20 Class , Power consumtion is
2W & is supplied via external adaptor or through power over ethernet (POE). It can be mounted over
standard 35MM DIn rails or suspension hole on the housing base, on wall or on solid vertical serfaces.
Dimension of 54mm x 91mm X 62mm & weight no more than 100gms. Operating ambeint temprature to
be within 0 deg to 50 Deg C, Storage temp of -10Deg to + 70 Deg C. Interface 2 X DMX 512 /RDM
invidually Isolated(1kV) 3-pin perminal plug. VDMXmax /V DMXmin = 4.8V/0.8V, Short circuit protected, I
SC Max = 62mA. Ethernet Port 1 X e:net 10/100 Mbits - RJ45. Hosuing material amde of self
extinguishing blend of PC/ABS with UL Document E140692, With Electrical safety-SELV Compliant & CE
certified having all test supporting documents All Above to be covered under 5 Year System Warranty
(Osram Traxon/)
6
-
-
... More
od98408/2023_2024
Supply and Installation Testing and commissioning of Master Controller Designed to to control fixture in
projects to controls & orchestrate all devices/pixels/fixtures within one project. having the capability &
capacity to integrate various external engines along various other devices & content as well. The
controller has to be automated solution for integration possibilties of DMX /DALI facade & Architectectural
Project that can also be mounted on DIN rail 35mm. Master Controller should be a fanless operation High
Quality , realiable & certified components built in for industrial use, supporting ethernet based Protocals.
Supporting headless operation with microSD card slot as memory to store the programme files to be
saved and operated without keybord & monitor after commissioning. Master controller unit should have
PC Body Housing DImensions (W)72mm X (H)91mm X (D)62mm with weight no more than 150gms, IP
20 class . Power supply external 24V DC input 12W, with reverse polarity . Operating Ambient temprature
0 Deg to 40Deg C & Storage temprature -10 Deg to + 70 Deg C . Master Controller Should have 4 LEDs
to show master/slave, error, ethernet and power status. Master Controller to be CE certified & having all
supporting test reports as per declaration. Self extinguishing blend PC/ABS, UL document E140692.
System interfaces 1 x e:net/Ethernet, RJ45 CAT5 shielded USB 2.0 Type A. Mass memory microSD card
(Osram Traxon/Equivalent )
1
-
-
... More
od98458/2023_2024
Supply, installation , testing & commissioning of Surface mounted, 1000mm - 1250mm long 36W linear
LED fixture (IP65) with following specifications: 15° x 30° optics (Tolerance ±2 degree x ±2 degree),
3000K CCT, fixture shall be equipped with minimum IK06, IP65. Power Supply should be non intergral
part of the luminaire and should have 70% Efficiency with Power Factor of 0.9. Power supply should
be of IP65 and placed in a suitable size of outdoor grade polycarbonate junction box with terminal block.
Input voltage 24V DC. The luminaire shall be loop in - loop out compatibility and should be inter-likable
with connecting cable of suitable size and IP65 5 pin/3 pin/ T connectors. Die cast alumunium housing &
clear glass cover housing. Luminaire should be BIS certified. Lumen maintenance of 70% at 50000
burning hours at 25 deg C. The power consumption of the prodcut should not be more than 36W. The
luminaire manufacturer shall provide optical performance, polar diagrams and photometric data in various
formats including IES file format in accordance with IES LM- 79-08.(Osram Traxon/Equivalent)
285
-
-
... More
od98459/2023_2024
Supply, installation , testing & commissioning of Surface mounted, 500mm - 600mm long 18W linear LED
fixture (IP65) with following specifications: 15° x 30° optics (Tolerance ±2 degree x ±2 degree), 3000K
CCT, fixture shall be equipped with minimum IK06, IP65. Power Supply should be non intergral part of
the luminaire and should have 70% Efficiency with Power Factor of 0.9. Power supply should be of
IP65 and placed in a suitable size of outdoor grade polycarbonate junction box with terminal block. Input
voltage 24V DC. The luminaire shall be loop in - loop out compatibility and should be inter-likable with
connecting cable of suitable size and IP65 5 pin/3 pin/ T connectors. Die cast alumunium housing & clear
glass cover housing. Luminaire should be BIS certified. Lumen maintenance of 70% at 50000 burning
hours at 25 deg C. The power consumption of the prodcut should not be more than 18W. The luminaire
manufacturer shall provide optical performance, polar diagrams and photometric data in various formats
including IES file format in accordance with IES LM- 79-08.(Osram Traxon/Equivalent)
16
-
-
... More
od98844/2023_2024
Supply, installation , testing & commissioning of Surface mounted, 50/54 W 24pcs LED washer out door
light fixture IP66 IK o7 adjustable -90 to +90, 3000K CCT Power Supply should be non intergral part of
the luminaire and should have 70% Efficiency with Power Factor of 0.9. . Die cast alumunium housing
& clear glass cover housing. Luminaire should be BIS certified. Lumen maintenance of 70% at 50000
burning hours at 25 deg C. The power consumption of the prodcut should not be more than 54W. The
luminaire manufacturer shall provide optical performance, polar diagrams and photometric data in various
formats including IES file format in accordance with IES LM- 79-08.(Osram Traxon Washer
GO/Equivalent)
4
-
-
... More
od99805/2023_2024
Additional labour charges for fixing LED light fittings/other accessories above 5 metre height using
suitable scaffolding etc.as required.
180
-
-
... More
od98409/2023_2024
Supply and connecting Injection moulded factory prefitted IP66/67 Rated 5 pin Y-Cable for continuation of
DMX data and adding 24V Power (Osram Traxon/Equivalent)
8
-
-
... More
od98410/2023_2024
brSupply and connecting 1 METER 5 pin starter cable with 2x1.0 sqmm, 3x0.5sqmm in one 7.8mm dia
sheathed cable along with 16.8mm dia female IP connected pre factory fitted. One side open and another
side of the cable with factory pre-fitted connector.(Osram Traxon/equivalent)
12
-
-
... More
od98411/2023_2024
Supply and connecting 500mm 4 -pin cable for DMX Data input with 4 x0.5 Sqmm cable for DMX+, DMX-
, Address and Ground signal (Osram Traxon/equivalent)
2
-
-
... More
od99779/2023_2024
Supply and connecting1 METER 2 pin starter sheathed cable along with female IP connected pre factory
fitted. One side open and another and another side of the cable with factory pre-fitted connector.(Osram
Traxon/Equivalent)
96
-
-
... More
od98412/2023_2024
Supply and providing IP66/67 Rated 200W 24V Constant Voltage driver with Output ripple Voltage (100
Hz) 2 % along with in-built Overheating protection, Overload protection, Short-circuit protection and
Robust and durable design for outdoor applications., Surge protection: up to 4 kV (L-N) / 6 kV (L/N-PE)
(Osram Traxon/Equivalent))
88
-
-
... More
od98413/2023_2024
Supply and providing IP66/67 Rated 150W 24V Constant Voltage driver with Output ripple Voltage (100
Hz) 2 % along with in-built Overheating protection, Overload protection, Short-circuit protection and
Robust and durable design for outdoor applications., Surge protection: up to 4 kV (L-N) / 6 kV (L/N-PE).
(Osram Traxon/Equivalent)
12
-
-
... More
od99033/2023_2024
Supply and Installing IP66/67 Rated 150W 24V Constant Voltage driver (OT 50 driver 24V) with Output
ripple Voltage (100 Hz) 2 % along with in-built Overheating protection, Overload protection, Short-circuit
protection and Robust and durable design for outdoor applications., Surge protection: up to 4 kV (L-N) / 6
kV (L/N-PE) (Osram Traxon/Equivalent)
2
-
-
... More
od96365/2023_2024
Supply and providing 8 port network switch
1
-
-
... More
od210917/2023_2024
Supply and Installation of 316L grade stainless steel marine grade flexible mounting channel for flexible
ribbon fixture shall fit properly. Mounting channel shall have property of anti-corrosion salt water
resistance chlorine water resistance UV resistance and longlife span including supply of screws for
mounting shall have same property of marine grade SS 316L.
130
-
-
... More
90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm
1000
-
-
... More
90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required25 mm
1800
-
-
... More
90.9.1.1
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.50x50mm Cable Management
System with base and lid
200
-
-
... More
90.9.1.2
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.External angle 90 degree
6
-
-
... More
90.9.1.3
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.Flat angle 90 Degree /Tee
6
-
-
... More
90.9.1.7
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.End cap
6
-
-
... More
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
720
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
100
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
6
-
-
... More
90.6.5.12
Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V
grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface /
recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq
mm
3000
-
-
... More
1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
100
-
-
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
200
-
-
... More
1.17.4
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
120
-
-
... More
1.17.5
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
180
-
-
... More
1.17.6
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
140
-
-
... More
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
100
-
-
... More
1.17.12
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
180
-
-
... More
1.17.13
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
120
-
-
... More
1.17.14
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm
120
-
-
... More
1.17.15
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
100
-
-
... More
90.11.1.10
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP
42/43)
4
-
-
... More
90.11.1.15
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB
with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP
42/43)
1
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
40
-
-
... More
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
5
-
-
... More
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
11
-
-
... More
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
4
-
-
... More
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
4
-
-
... More
2.15.3
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.24.1
Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and
neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and
commissioning etc. as required.For 4 way, Double door TPN MCBDB
4
-
-
... More
90.12.7.39
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with
factory made clamp
360
-
-
... More
90.12.7.41
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with
factory made clamp
50
-
-
... More
9.1.1
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.2 X 6 sq. mm (19mm)
8
-
-
... More
9.1.33
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 16 sq. mm (28mm)
2
-
-
Evaluation Notes How It Works ?