Guruvayur Devaswom Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 15,250Document Cost
₹ 1,350Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GD_663519_1Bid Award Id
ViewTender No
E3-3762/21Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Rewiring First floor of Main building Sree Krishna Higher Secondary School under GuruvayurDevaswom.
BOQ Items
90.2.1.13
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined
plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light
points.
9
-
-
90.2.1.14
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent
Plug - Medium Point
6
-
-
90.3.20.3
Supply & installation of light fittings on TW round blockbrSupply, conveyance installation testing and
commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all
accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the
fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire
conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type
fixture
40
-
-
90.3.21.3
Supply & installation of light fittings on 'C/U' shaped flat iron bracketbrSupply, conveyance, installation,
testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete
with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS
flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper
conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.
as required.1200 mm 1X20W LED Lamp with box type fixture
12
-
-
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
30
-
-
od71045/2023_2024
Supply, conveyance, installation, testing and cmmissioning of ceiling fan of all sizes using standard
accessories including wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V
grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200mm
sweep 5 star rated 26/28W at maximum speed BLDC ceiling fan with service value greater than or equal
to 6 complete with 260mm down rod , canopies, shackeles and blades working on 230V/240V single
phase A/C.
44
-
-
od71046/2023_2024
Supply, installation , testing and commissioning of 300/305 mm heavy duty exhaust fan 900 rpm in metal
body working on 230V single phase A/C supply in the existing opening including making the holes to suit
the size of the above fan, fixing necessary bolt and nuts making good the damages etc. as required
including giving connections
2
-
-
90.3.18.2
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and
welded to shape and fixing the same to wall / parapet using clamps as noted along with each size,
painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the
damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
9
-
-
od71047/2023_2024
Supply installation testing and commissioning of 60W LED Street light fitting with IP66
protection,120lm/w,PF0.95,Make of chip Cree/Lumilled/Nichia pressure die cast body, bottom
toughened glass, secondary lens for optium light spread, potted driver,life 50000@L70 on exsisting GI
pipe and giving connection.LM79&80 certificates to be produced mentioning chip manufacturer.(Ledenvo
Osram/equivalent).
6
-
-
90.4.8
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including
plastering colour washing etc. as required.
2
-
-
90.9.1.1
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.50x50mm Cable Management
System with base and lid
50
-
-
90.9.1.2
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.External angle 90 degree
4
-
-
90.9.1.4
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.Internal angle 90 degree
4
-
-
90.9.1.7
Supply and fixing 50 x 50 mm PVC Cable Management System with base and lid along with the following
accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and
making good the damages in case of recessed installation as required.End cap
4
-
-
90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm
310
-
-
90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required25 mm
50
-
-
1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
120
-
-
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
80
-
-
1.17.4
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
100
-
-
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
20
-
-
1.17.13
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
30
-
-
1.17.22
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
40
-
-
1.17.15
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
10
-
-
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.5/6 amps switch
12
-
-
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
4
-
-
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
18
-
-
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
4
-
-
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.3 Module (100mmX75mm)
7
-
-
1.27.5
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.8 Module (125mmX125mm)
7
-
-
1.26
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular
plate as required.
9
-
-
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding
connection etc as required.
6
-
-
90.11.1.10
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP
42/43)
1
-
-
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP
42/43)
1
-
-
90.11.1.15
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB
with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP
42/43)
1
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole)
22
-
-
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
3
-
-
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
12
-
-
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
2
-
-
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
2
-
-
90.12.7.41
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with
factory made clamp
20
-
-
9.1.33
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 16 sq. mm (28mm)
2
-
-
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
360
-
-
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG))
120
-
-
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.00 mm (14 SWG)
30
-
-
90.16.5.2
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.65 mm (12 SWG)
8
-
-
Evaluation Notes How It Works ?