Guruvayur Devaswom Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 4,650Document Cost
₹ 550Tender Fee
Refer Documents
Summary
Electrification Of Swp Kaveedu Gokulam Guruvayur
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GD_649271_2Bid Award Id
ViewTender No
E3-9569/23Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Electrification of Sewage treatment plant and providing lighting at cattle shed at Kaveed Gokulam under Guruvayur Devaswom
BOQ Items
90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm
120
-
-
90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required25 mm
20
-
-
1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
30
-
-
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
10
-
-
1.17.4
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
30
-
-
1.17.5
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
10
-
-
1.17.6
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
10
-
-
1.17.7
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.7 x 1.5 sq. mm
10
-
-
1.17.8
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.8 x 1.5 sq. mm
20
-
-
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding
connection etc as required.
6
-
-
90.10.1.6
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )8 module
moulded plastic box on surface
1
-
-
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.5/6 amps switch
6
-
-
1.28.5
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.8 Module
1
-
-
1.26
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular
plate as required.
2
-
-
od271455/2023_2024
Supply installation testing and commissioning of LED High bay fitting 60W with efficacy upto
110lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty
LED Chip make Cree/Lumilled/Nichia Power factor 0.9,surge protection 10 KV and giving connection..( Klite
Polar High Bay1 Id KL 3113/equivalent)
4
-
-
od271646/2023_2024
Supply installation testing and commissioning of LED Flood light fitting 60W with efficacy upto
150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty
LED Chip make Cree/Lumilled/Nichia Power factor 0.9 and giving connection.LM 79&80 certificates to be
produced.(Aston prime K-lite Id 4200/equivalent)
2
-
-
90.11.1.19
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB
with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
2.3.3
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12
way, Double door
2
-
-
2.3.1
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6
way, Double door
1
-
-
90.14.10.3
Supply, conveyance and fixing the following types & current rated control gears & switchgears
conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as
required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting
range of 80 - 100% with thermal magnetic release having adjustable OL
1
-
-
2.10.3
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Double pole
2
-
-
2.12.1
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete
with connections, testing and commissioning etc. as required.40 amps
2
-
-
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
16
-
-
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
1
-
-
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
10
-
-
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
2.14.1
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.25 amps
1
-
-
90.12.5.1
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.2 core 4 sq mm
10
-
-
90.12.7.1
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with
factory made clamp
10
-
-
90.12.5.40
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.4 core 10 sq mm
30
-
-
90.12.7.40
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with
factory made clamp
20
-
-
90.12.10.2
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or
nearest size
30
-
-
9.1.32
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
2
-
-
od271863/2023_2024
Supplying and making end termination with brass compression gland and aluminium lugs for
brfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
brgrade as required.br2 X 4 sq. mm
4
-
-
90.16.2.3
Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including
excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
10
-
-
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
140
-
-
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
20
-
-
5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding
masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.
with charcoal/ coke and salt as required.
2
-
-
5.15
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
10
-
-
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
50
-
-
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.00 mm (14 SWG)
14
-
-
90.16.5.2
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.65 mm (12 SWG)
4
-
-
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
6
-
-
od271808/2023_2024
Demolishing cement concrete using necessary equipments and removing debries from site.
0.24
-
-