Guruvayur Devaswom Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 30,500Document Cost
₹ 2,760Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GD_711382_1Bid Award Id
ViewTender No
E3-3771/2024Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Standardisation of Panel board at filter plant and Fire Pump room (Temple Pond) Guruvayur.
BOQ Items
... More
90.14.3.1
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene
beeding suitable for 1.60/ 2.00 mm sheet
20
-
-
... More
90.14.4
Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled
steel channel (ISMC)
6
-
-
... More
90.14.5
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel
board
300
-
-
... More
90.14.6
Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber,
suitable size nut & bolt, providng heat shrink sleeves etc. as required.
7600
-
-
... More
90.14.7
Supply and providing copper earth bus in the panel board
1200
-
-
... More
od40322/2024_2025
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board
with 200A ISI marked HRC fuse links including drilling holes in cubicle panel, making connections, etc. as
required.br250 Amp TP & N SDF
1
-
-
... More
2.1.2
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board
with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as
required.63 Amp TP & N
3
-
-
... More
2.1.3
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board
with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as
required.100 Amp TP&N
4
-
-
... More
90.14.10.4
Supply, conveyance and fixing the following types & current rated control gears & switchgears
conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as
required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting
range of 80 - 100% with thermal magnetic release having adjustable OL
6
-
-
... More
90.14.10.3
Supply, conveyance and fixing the following types & current rated control gears & switchgears
conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as
required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting
range of 80 - 100% with thermal magnetic release having adjustable OL
3
-
-
... More
od38993/2024_2025
Supply, conveyance and fixing the following types & current rated control gears & switchgears
conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as
required.br250A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting
range of 80 - 100% with thermal magnetic release having adjustable OL (L&T DN1250C/Equivalent)
1
-
-
... More
od38996/2024_2025
Supply, conveyance and fixing the following types & current rated control gears & switchgears
conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as
required.br125A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting
range of 80 - 100% with thermal magnetic release having adjustable OL (L&T DN1250C/Equivalent)
1
-
-
... More
od38998/2024_2025
Disconnecting the end termination of 300 sq.mm UG Cable 315/400 A TPNSDF etc. from the exsisting
enclosure and refixing in the proposed panel board end termination of 300 sq.mm cable including giving
connection from the busbar etc. as required.
1
-
-
... More
90.14.11.3
MCCB AccessoriesSupply and fixing one number earth fault Relay up to 250A to 400A with CBCT.
1
-
-
... More
90.14.11.12
MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A.
1
-
-
... More
90.14.11.13
MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door
interlock ) in the existing MCCB of rating up to 250 A
7
-
-
... More
od40384/2024_2025
Installation of Cable tray using required accessories such as Box Rail Bracket 2.0mm thick Heavy Duty
100mm top length x 265mm Side Ht with 3.0mm thick 2 hole base plate not exceeding 1.5 mtre span (
100 x 10.5 Slot 10.5 base hole GI 300 mm width 60 mm height (OBO/Legrand/Hi Tech)
140
-
-
... More
od40385/2024_2025
Supply of Perforated hot dip galvanized Cable tray conforming to IEC-61537. The Tray shall be
galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested
for a max. safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be
within the limits as per standard. The safety factor shall be 1.7 times of the saem wfe working load. Size
300 mm width x 60mm Height (OBO/Legrand/Indiana)
200
-
-
... More
90.11.1.15
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB
with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP
42/43)
1
-
-
... More
90.11.1.19
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB
with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
3
-
-
... More
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP
42/43)
1
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
20
-
-
... More
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
12
-
-
... More
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
40
-
-
... More
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.13.2
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.15.3
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C"
curve DP MCB complete with connections, testing and commissioning etc. as required.
3
-
-
... More
2.19
Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal
enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess,
with chained metal cover for the socket out let and complete with connections, testing and commissioning
etc. as required.
3
-
-
... More
2.17
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415volts "C"
curve TP MCB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
90.12.7.40
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with
factory made clamp
200
-
-
... More
90.12.5.41
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.4 core 16 sq mm
45
-
-
... More
90.12.6.41
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV
grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm
10
-
-
... More
90.12.6.42
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV
grade of the following sizes in the existing masonry open duct as required.4 core 25 sq mm
20
-
-
... More
90.12.5.42
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of
1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as
required.4 core 25 sq mm
55
-
-
... More
90.12.7.29
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm
with factory made clamp
10
-
-
... More
90.12.7.30
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
15
-
-
... More
9.1.32
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
2
-
-
... More
90.12.7.41
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with
factory made clamp
90
-
-
... More
90.12.7.42
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with
factory made clamp
285
-
-
... More
9.1.22
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.3 1/2 X 50 sq. mm (35mm)
4
-
-
... More
9.1.33
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 16 sq. mm (28mm)
6
-
-
... More
9.1.34
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 25 sq. mm (28mm)
4
-
-
... More
90.12.10.3
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or
nearest size
61
-
-
... More
90.16.2.5
Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including
excavating trench of suitable size and refilling etc, as required.50 mm dia. G.I. pipe (medium class
40
-
-
... More
90.6.6.3
Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat
cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving
necessary connections of the following sizes.4 sq mm
10
-
-
... More
90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required20 mm
90
-
-
... More
90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess
including cutting the wall and making good the same in case of recessed conduit as required25 mm
150
-
-
... More
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
20
-
-
... More
1.17.13
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
10
-
-
... More
1.17.20
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
60
-
-
... More
1.17.22
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
130
-
-
... More
1.17.31
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
20
-
-
... More
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
2
-
-
... More
90.10.3.14
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )25A SP switch with indicator
1
-
-
... More
90.10.3.15
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )32A DP switch with indicator
1
-
-
... More
90.10.3.33
Supply and Fixing the following modular switches & accessories in the existing front plates and giving
necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
2
-
-
... More
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2
-
-
... More
1.27.2
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.3 Module (100mmX75mm)
2
-
-
... More
1.27.3
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular
switches in recess etc as required.4 Module (125mmX75mm).
2
-
-
... More
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
120
-
-
... More
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
640
-
-
... More
90.16.1.3
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required3.15 mm copper conductor ( 10 SWG)
380
-
-
... More
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.00 mm (14 SWG)
10
-
-
... More
90.16.5.2
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.65 mm (12 SWG)
6
-
-
... More
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.3.15 mm (10 SWG)
12
-
-
... More
od40826/2024_2025
Demolishing the cement concrete and removing the materials from site.
2
-
-
... More
14.7
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
2
-
-
... More
od44886/2024_2025
Charges for preperation of Schematic drawing in Auto Cad after conducting field survey in A3 sheet
2
-
-
... More
od44887/2024_2025
Charges for providing additional copies of Schematic drawing/Sketch
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements