Guruvayur Devaswom Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 13,800Document Cost
₹ 1,105Tender Fee
Refer Documents
Summary
Electrification Of Newly Constructed Nadapanthal Under Sponsorship Near
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_GD_723586_1Tender No
E3-3445/24Tender Authority
Guruvayur Devaswom ViewPurchaser Address
-Website
http://https://guruvayurdevaswom.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Electrification of newly constructed Nadapanthal under sponsorship near Bhagavathy temple side entrance Guruvayur
BOQ Items
... More
1.17.3
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
100
-
-
... More
1.17.4
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 1.5 sq. mm
80
-
-
... More
1.17.5
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm
80
-
-
... More
1.17.6
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
120
-
-
... More
1.17.9
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
60
-
-
... More
1.17.11
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
45
-
-
... More
1.17.13
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the
existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
30
-
-
... More
1.24.1
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.5/6 amps switch
23
-
-
... More
1.24.3
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.15/16 amp switch
2
-
-
... More
1.24.4
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
12
-
-
... More
1.24.5
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box
including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2
-
-
... More
1.26
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular
plate as required.
1
-
-
... More
90.10.1.2
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )2 module
moulded plastic box on surface.
10
-
-
... More
90.10.1.3
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )3 module
moulded plastic box on surface
8
-
-
... More
90.10.1.4
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )4 module
moulded plastic box on surface
2
-
-
... More
90.10.1.5
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess
including making good the damages, colour washing etc as required (RoHS compliant )6 module
moulded plastic box on surface
2
-
-
... More
1.28.1
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.1 or 2 Module
10
-
-
... More
1.28.2
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.3 Module
8
-
-
... More
1.28.3
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.4 Module
2
-
-
... More
1.28.4
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as
required.6 Module
2
-
-
... More
1.33
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding
connection etc as required.
13
-
-
... More
90.16.1.1
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.00 mm copper conductor ( 14 SWG)
80
-
-
... More
90.16.1.2
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving
connection as required2.65 mm copper conductor (12 SWG)
240
-
-
... More
90.16.5.1
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.00 mm (14 SWG)
75
-
-
... More
90.16.5.2
Supply of superior quality copper earth socket for the following size of earth conductor including crimping
etc. as required.2.65 mm (12 SWG)
4
-
-
... More
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of
MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/
isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall ,
making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP
42/43)
1
-
-
... More
2.10.1
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Single pole
14
-
-
... More
2.10.4
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the existing MCB DB complete with connections, testing
and commissioning etc. as required.Triple pole
1
-
-
... More
2.11
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required
4
-
-
... More
2.13.1
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.15.2
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current
circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with
connections, testing and commissioning etc. as required.40 amps
1
-
-
... More
2.16
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C"
curve DP MCB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
90.12.7.40
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power
cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps
not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with
factory made clamp
120
-
-
... More
9.1.32
Supplying and making end termination with brass compression gland and aluminium lugs for following
size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
required.4 X 10 sq. mm (25mm)
2
-
-
... More
od102617/2024_2025
Supply and Installation of base plate minimum size 200X150mm for fixing heavy duty wall fan made of
2mm or nearest size sheet weided/bolted to exsisting pillar neatly painted etc. as required
10
-
-
... More
od102618/2024_2025
Supply and Installing Heavy duty wall mounted fan 600mm with regulator on wall using suitable nut bolt
etc as required (Almonard/Equivalent)
10
-
-
... More
od102619/2024_2025
Additional labour charges for fixing LED light fittings/other accessories above 5 metre height using
suitable scaffolding etc.as required.
6
-
-
... More
od102620/2024_2025
Supply installation testing and commissioning of LED High bay fitting 60W with efficacy upto
150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty
LED Chip make Cree/Lumilled/Nichia Power factor 0.9,surge protection 10 KV and giving connection..( Klite Polar Prime High Bay 1 Id 3187/equivalent)
2
-
-
... More
od102621/2024_2025
Supply installation testing and commissioning of LED High bay fitting 2X60W with efficacy upto
150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty
LED Chip make Cree/Lumilled/Nichia Power factor 0.9,surge protection 10 KV and giving connection..( Klite Polar Prime High Bay 2 Id 3188/equivalent)
2
-
-
... More
od102622/2024_2025
Supply installation testing and commissioning of LED Flood light fitting 2X60W with efficacy upto
150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty
LED Chip make Cree/Lumilled/Nichia Power factor 0.9 and giving connection.LM 79&80 certificates to be
produced.(Aston prime K-lite Id 4201/equivalent)
4
-
-
... More
od102623/2024_2025
Supply installation testing and commissioning of LED Flood light fitting 60W with efficacy upto
150lm/w,Surge protection 10KV,IP68 for LED chamber and IP67 for driver compartment,5 years warranty
LED Chip make Cree/Lumilled/Nichia Power factor 0.9 and giving connection.LM 79&80 certificates to be
produced.(Aston prime K-lite Id 4200/equivalent)
5
-
-
... More
od103172/2024_2025
Labour charge for removing unwanted wires in the wiring area, including by arranging suitable scaffolding checking whether the connections are live or not and removing switches, switchboards, and old light fittings
30
-
-
... More
od103173/2024_2025
Labour charge for clamping the existing hanging cable/wire using cable clamp/ cable tie etc by arranging suitable scaffolding
10
-
-
... More
od103219/2024_2025
Labour charges for disconnecting and removing the old flood lights above 7m heights by providing
suitable scaffolding etc. as required.
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%