Greater Cochin Development Authority Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 18,400Document Cost
₹ 1,575Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_GCDA_705399_1Tender No
E4/8713/2024/GCDATender Authority
Greater Cochin Development Authority ViewPurchaser Address
-Website
http://http://gcda.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
10
-
-
1.7.3 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wire
40
-
-
1.17.31 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
15
-
-
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
13
-
-
90.12.24.3 : Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.
8
-
-
1.55.1 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
19
-
-
90.4.5.2 : Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
2
-
-
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2
-
-
90.10.1.2 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
2
-
-
90.4.9 : Charges for cutting holes suitable for accommodating exhaust fans above 305mm sweep and up to 450mm sweep including plastering colour washing etc. as required.
3
-
-
od160669/2024_2025 : Supply of exhaust fan of size upto 305mm
3
-
-
90.4.10 : Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
3
-
-
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
11
-
-
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
10
-
-
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
10
-
-
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
11
-
-
90.10.1.3 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
21
-
-
90.10.1.5 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )
12
-
-
90.4.6 : Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan.
5
-
-
od103414/2024_2025 : Supply of 400mm sweep wall mounting fan
5
-
-
od103447/2024_2025 : Supply, Installation, testing and commissioning of Air Cooled High Wall mounted<br>Split Air Conditioner of 1.5 TR capacity consisting of high wall mounted type room<br>unit with cordless remote control and one number outdoor condensing unit<br>comprising of energy efficient suitable Inverter type rotary compressor for operation<br>on single phase, 230 V, 50 Hz supply, fixing the outdoor unit on raised platform as<br>per manufacturers recommendation and fixing of room ( fan Coil) unit on wall up to<br>10m distance refrigerent copper pipinh with 13mm nitril rubber insulation, providing<br>and making interconnection between room and condenser as per site conditions,<br>comprising of 1" dia drain PVC pipe with insulation 10 m, canvas connection,<br>full electrical cabling from power plug near indoor unit and out door unit, vibration<br>isolation, ODU MS stand, first charge refrigarant gas, min 3 star rated as per BEE<br>suitable stabilizer etc. complete as required.
1
-
-
od160980/2024_2025 : Supply, Installation, testing and commissioning of Air Cooled High Wall mounted Split Air Conditioner of 0.75 TR capacity consisting of high wall mounted type room unit with cordless remote control and one number outdoor condensing unit comprising of energy efficient suitable Inverter type rotary compressor for operation on single phase, 230 V, 50 Hz supply, fixing the outdoor unit on raised platform as per manufacturers recommendation and fixing of room ( fan Coil) unit on wall up to 10m distance refrigerent copper piping with 13mm nitril rubber insulation, providing and making interconnection between room and condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 10 m, canvas connection, full electrical cabling from power plug near indoor unit and out door unit, vibration isolation, ODU MS stand, first charge refrigerant gas, min 3 star rated as per BEE suitable stabilizer etc. complete as required.
2
-
-
od104511/2024_2025 : Supply, Installation, testing and commissioning of Inverter type Air Cooled High<br>Wall mounted Split Air Conditioner of 2 TR capacity consisting of high wall mounted<br>type room unit with cordless remote control and one number outdoor condensing unit<br>comprising of energy efficient suitable rotary compressor for operation on single<br>phase, 230 V, 50 Hz supply, fixing the outdoor unit on raised platform as per<br>manufacturers recommendation and fixing of room ( fan Coil) unit on wall up to 10m<br>distance refrigerant copper piping with 13mm nitril rubber insulation, providing and<br>making interconnection between room and condenser as per site conditions,<br>comprising of 1" dia drain PVC pipe with insulation 10 m, canvas connection,<br>full electrical cabling from power plug near indoor unit and out door unit, vibration<br>isolation, ODU MS stand, first charge refrigerant gas. Min 3 star as per BEE suitable stabilizer<br>etc. complete as required.
5
-
-
90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required
6
-
-
od104512/2024_2025 : Supply, conveyance, installation and testing of 12 Watts Indoor Ceiling track Light(Warm White) fixed on Flexibly Rotatable Light Head
19
-
-
od104513/2024_2025 : Supply Conveyance, installation, testing and commissioning of 2250mmX2250mmX12mm size18 watt square LED downlight, 3000 light, 5000k white light
22
-
-
1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required.
8
-
-
od104514/2024_2025 : Supply Conveyance, installation, testing and commissioning of 9W,230V,50Hz,LED bulb
8
-
-
od104781/2024_2025 : Supply, Installation, testing and commissioning of 5 star rated 0.5HP water Pump
1
-
-
od106422/2024_2025 : Dismantling of existing wiring, DB and other boards and keeping its safely at a place as per the instruction of site engineer
1
-
-
DB,MCB, isolator, earthing,
-
-
-
2.4.2 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way (4 + 18), Double door
1
-
-
2.4.1 : Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
1
-
-
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
1
-
-
2.10.2 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
1
-
-
2.5.2 : Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door
1
-
-
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
od171580/2024_2025 : Supplying and fixing 40amps 415volts "C" curve 4P MCB complete with connections, testing and commissioning etc. as required
1
-
-
od171581/2024_2025 : Supply, installation, testing and commissioning of 2kVA ONLINE UPS with battery interlink cables, battery rack etc
1
-
-
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
12
-
-
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
3
-
-
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
od160352/2024_2025 : Fabrication, supply & installation of dust and vermin proof, wall mounting, Sintex make Code No 3525 meter box suitable for fixing KSEB meter,fuse units, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
1
-
-
od160353/2024_2025 : Supply and fixing 100A, 415 V, DIN type fuse with base
3
-
-
od160355/2024_2025 : Supply and fixing 100 A, 2 Way neutral links mounted on DMC/SMC base
1
-
-
od171630/2024_2025 : All documentaion works including preparation of all authority standard drawings, submitting KSEB, obtaining power allocation & permanent power connection, etc. and commissioning of the whole installation in the premises. (All statutory payments will be reimbursed with original receipts.)
1
-
-
5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth
electrode, including connection/ termination with GI thimble etc. as required.
10
-
-
5.16 : Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
6
-
-
Fire extinguishers
-
-
-
od171640/2024_2025 : Supply Installation Testing, Commissioning of fire extinguisher ABC type 5 kg. Capacity complete with initial charges and installation brackets.
2
-
-