Forest Department Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 8,100Document Cost
₹ 800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_FD_681907_1Tender No
04/2024-25Tender Authority
Forest Department ViewPurchaser Address
-Website
http://http://www.forest.kerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
10
778
77.83
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
3
321
107.18
OD92689/2023-2024 Supplying and providing the following types and power rated lamps in the existing threaded type fittings as required.E27LED bulb 9W
3
348
116.15
90.3.21.3 Supply& Installation of light fittings on C/U shaped flat iron bracket supply, conveyance,installation,testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc directly on wall using 2 nos C/U brackets made from 20 x 3 mm MS flat.painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevent ISS or extending the original wiring and giving connection etc as required 1200mm 1X20W LED Lamp with box type fixture
4
5153
1288.29
90.3.20.3 Supply& Installation of light fittings on TW round block supply, conveyance,installation,testing and commissioning the light fittings of following types made of CRCA with 0.5 mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevent ISS and giving connections as required 1200mm 1X20W LED Lamp with box type fixture
1
1251
1251.79
OD99500/2023-2024 Supply and fixing cast aluminium stove enamelled bulk head fitting with heat resistant prismatic glass suitable for providing 7/9 w LED bulb on wall /ceiling and giving connection with 16/.20 mm pvc insulated and sheathed copper conductor flex wire or extending wiring and making good the surface of wall etc as required
1
487
487.73
OD99543/2023-2024 Supply,conveyance ,installation testing and commissioning of 1800 lumen round/square(IXI) recessed fitting made of diecast aluminium,having efficancy not less than 1101/w,pf greater than 0.95,THD less than or equal to 10%,Chip make Cree/Osram/Lumilled/Nichea
16
40467
2529.23
90.15.4.2 Supply conveyance ,installation, testing and commissioning of 36/40 W LED street light output greater than 105 lumen/W 4000-6000K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV and Aluminium pressure die-cast powder coated housing,acrylic cover complete with THD less than 10% power factor greater than 0.98 RoHS compliant,duly wired up for use on 230 V AC supply Driver compartment should be seperatly accessible for maintenance (LM 79& amp:80 certificates from NABL accredited third party lab to be produced mentioning chip manufacturer.
2
9239
4619.9
90.4.5.4 Supply Installation testing and commisioning of ceiling fan of following sizes including wiring the down roads of standerd lenghth (up to 30 cm) with 1.5 sq.mm FRLS PVC insulated copper conductor,single core cable etc as required.1200mm sweep-ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt),Air delivery minimum 210(cubic meter/minute),copper winding suitable for 230V single for 230V/240V single phase ACsupply
7
15422
2203.15
90.4.1
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required
7
1226
175.18
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required
3
1429
476.35
OD92690/2023-2024
Supply and fixing 200mm light duty exhaust fan plastic body with self opening lauvers using required bolt,nut etc
3
4275
1425.3
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
60
5956
99.28
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
20
2149
107.48
90.9.1.1 Supply and fixing 50x50 mm PVC CableManagement system with base and lid along with the following accessories conforming to IEC 61084/BS476 & amp:4678 on surface /recess including cutting the wall and making good the damages in case of recessed installation as required End cap
30
23369
778.99
90.9.1.7 Supply and fixing 50x50 mm PVC CableManagement system with base and lid along with the following accessories conforming to IEC 61084/BS476 & amp:4678 on surface /recess including cutting the wall and making good the damages in case of recessed installation as required End cap
2
200
100.43
1.21.3 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
3
328
109.56
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
70
4495
64.22
1.17.6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required 6 x 1.5 sq. mm
35
4160
118.86
1.17.5 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required 5 x 1.5 sq. mm
15
1557
103.83
1.17.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required 9 x 1.5 sq. mm
10
1926
192.63
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 2.5 sq. mm
42
3749
89.27
1.17.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required 6 x 2.5 sq. mm
25
4224
168.96
1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required 3 x 4 sq. mm
30
4167
138.91
1.17.24 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required 6 x 4 sq. mm
3
787
262.52
1.17.31 Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface/ recessed steel/ PVC conduit as required 4 x 6 sq. mm
20
5231
261.57
1.27.1 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
6
1732
288.78
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 3 Module (100mmX75mm)
14
4450
317.9
1.27.5 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 8 Module (125mmX125mm)
2
910
455.08
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
11
1115
101.45
1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
6
939
156.57
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
15
1979
131.94
1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
6
1246
207.76
90.10.3.14
Supplying and fixing the following modular switch&:accessories in the existing modular plates and giving necessary connections as required.(RoHS compliant)25A SP switch with indicator
2
528
264.08
90.10.3.32
Supply and fixing the following modular switch&:accessories in the existing front plates and giving necessary connections as required.(RoHS compliant)25A 3 pin plug top with indicator
2
256
128.18
90.10.3.33
Supply and fixing the following modular switch&:accessories in the existing front plates and giving necessary connections as required.(RoHS compliant)25A 3 pin shuttered socket
2
633
316.61
90.11.1.14
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper/brass bus bar,neutral link,earth bus and DIN rail suitable for fixing MCB/ isolator etc.fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall making good the damages ,colour washing etc.as required 4 way (8+12)-double cover TPN vertical DB with provision for fixing 4P MCB /Isolator/RCCB/RCBO as incomer and SP/TP MCB as outgoing (IP 42/43)
1
6555
6555.87
90.11.1.11
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper/brass bus bar,neutral link,earth bus and DIN rail suitable for fixing MCB/ isolator etc.fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall making good the damages ,colour washing etc.as required 6 way (8+18)-three phase double cover (IP 42/43)
1
4515
4515.94
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
3
2946
982.02
OD92692/2023-2024
Supply and installation of the 40 A and 63 A,10 KA,TP MCB(C curve) suitable for 50Hz, AC supply conforming to IS 8828-1995/IEC 60898 of the following current ratings in the existing encloser and giving connections,as required.
1
1530
1530.3
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40amps
2
1978
989.2
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc.as required.40amps
2
6243
3121.58
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
18
4267
237.11
90.16.1.3
Supply and drawing bare earthing conductors of the following size along with wiring/cables and giving connection as required 3.15 mm copper conductor (10 SWG)
20
1270
63.51
90.16.5.3
Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc, as required 3.15mm (10 SWG)
6
161
26.9
OD92693/2023-2024
Supply and providing 25x6 mm brass nut and bolt etc as required
4
69
17.39
OD92694/2023-2024
Supply and providing 25x3 mm brass nut and bolt etc as required
15
334
22.31
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
14780
7390.03
OD92699/2023-2024
Supply and fixing the following accessories in the existing meter board and giving connections etc.(63 HRC Fuse Base with HRC Fuse link)
3
635
211.97
OD99501/2023-2024
Supply and Installation of 3 Phase sintex meter board suitable for fixing 3 phase KSEB meter cutouts, N/L,CT etc with hinged door construction with compartments if necessary providing vision panel for metercompartment,knockout for cable entry and exit.(GSMB 8135,815X350X230)
1
6408
6408.38
OD92700/2023-2024
Supply and fixing the following accessories in the existing meter board and giving connections etc.(63 A,2way neutral links mounted on DMC/SMC base)
1
264
264.15
OD92701/2023-2024
Supply and Installation of switch gear units in sheet steel enclosure complete with handle assembly,door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall ,making good the damages,colour washing etc including giving necessary connections as required.(excluding cost of HRC fuse links in case of SDF/SDFCO)(Front handle)63A,415V,50Hz,AC23 A duty,TPN SDF for DIN fuse
1
8107
8107.3
2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
1
1008
1008.53
Evaluation Notes How It Works ?